Loading...
HomeMy WebLinkAbout20160418 Ver 2_Stormwater Info_20170419 Homewood, Sue From: Brad Bailey <BBailey@4siteinc.biz> Sent: Wednesday, April 19, 2017 2:36 PM To: Homewood, Sue Cc: Melissa Ballard Subject: RE: Brevard Revised Plans Attachments: 16-137 Storm Plan 04-19-17.pdf Sue, Please see the updated storm plan attached, showing the diversion weir in structure "ST 3". Melissa will send over the O&M form tomorrow. Let me know if you need anything else. Bradley Bailey, El Project Engineer AF01 11 I T %or 7500 Memorial Parkway SW,Suite 209 Huntsville,AL 35802 Office: 256.539.1221 Fax: 256.539.1220 From: Homewood, Sue [mailto:sue.homewood@ncdenr.gov] Sent:Wednesday,April 19, 2017 10:06 AM To: Brad Bailey<BBailey@4siteinc.biz> Subject: RE: Brevard Revised Plans Click the link for the O&M EZ form on this website,you'll chose "proprietary system" on the cover page. Let me know if you have any trouble. Thanks, Sue Homewood Division of Water Resources, Winston Salem Regional Office Department of Environmental Quality 336 776 9693 office 336 813 1863 mobile Sue.Homewood(a-)ncdenr.gov 450 W. Hanes Mill Rd, Suite 300 Winston Salem NC 27105 1 ui STREAM PROTECTION NOTES: STORM STRUCTURES u (f) O c, 1. ALL WORK IN OR ADJACENT TO STREAM // / r I 1 I I I I I II III 11 I - ///// / // / / / / / / / / / NAME DESCRIPTION TOP ELEVATION I.E. IN I.E. OUT v Go / I III IIII II11�\ /// // / / / / / / < � m / n �1 I 1 I I I I 1 \ ///////// // / / / // / / / / / / // / / NYLOPLAST 18" DRAIN w O � WATERS SHALL BE CONDUCTED SO THAT / / I 11 I 1111 I I I II I \ /// / / / // / / / / / / / ST 1 RIM = 2741.82 2739.65 (E) THE FLOWING STREAM DOES NOT COME IN , / /1 / \�II 1 I I 1 I 1 I I I I III,^ �; \� /i///// / / / // / / / / / / / / / // BASIN W/SOLID COVER Q >so -� / / I✓� II IIIIIIIIIII \ 1 / //// / / / / c - CONTACT WITH THE DISTURBED AREA I.E. / / / II I 1 I I II �/ ///// / / / / / / / / / / / ST 2 BASIN WNYLOPLAST SOLID DRAIN RIM = 2743.17 2737.55 (W) 2737.45 (SW) z c / � III 1 I 1 I I 1 I \ I I � � //////// / // / / / // / / BASIN W/ SOLID COVER � g U n' �,I '/I /I/I// /I � IIII I II I \ IIII= ►1II IIII 1II1 II1 II II1I II II II I I II I I iIII//I I \II I I` _\- �i�/l�l//l///I//I//l iI/I/l//I////I l/ /////l//I/ // /////////l// / / / / ///I / o"IN THE DRY". (PER WATER QUALITY 41/ 's `al NYLOPLAST 30" DRAIN z-CERTIFICATION NO. 3890, CONDITION #6) ST 3 BASIN W/SOLID COVER RIM 2743.06 2737.35 (NE) >_ cn I/ 2737.25 (E) > C). 0�31(SEE ''PHASING PLAN" ON SHEET 5 FOR o0'f NYLOPLAST 30" DRAIN ADDITIONAL INFORMATION) ST 4 RIM 2742.34 2734.87 (E) 2734.77 (SW) o7lll / BASIN W/SOLID COVER I I I I I I I I I I I I I I I I IIIII llllll/1/ l l/ / l l I I I III I I I I I �3I 'Ill ( I II II I I II I II I ` ( \ ss II1I1I/1IlllIllI II 1 1I I l I I I I I I II I I I I I 2734..31 (E) wmoST 5 JUNCTION BOX RIM 2739.33 2734.21 (SW) J 2. NO CONSTRUCTION ACTIVITIES THAT 273431 (NE) INVOLVE DISTURBANCE OF THE STREAM �� I 21 11 � II 'I III \ \ - - - 1/ll/IIIIII/ I I I I I I 1 I 1 1 I 1 1 1 i i W o l I I /I l I I hI I I I _ - - ��//m00 %/I I/Io I I ST 6 JUNCTION BOX RIM = 2739.39 2736.73 (N) MAY TAKE PLACE DURING TROUT I N �, I l - // I I I I I I I I I I I ► 11 1 I / ST 9 IIII 1 , w ll w cU 11 IN 1 � � _ 2736.40 (S) SPAWNING SEASON (JAN. 1 - APRIL 15). ll� I IIII II ' 11 \ l'lllll, I I I III I I III N 1 I N I I I I cl I I I �, ST 7 JUNCTION BOX RIM - 2742.59 2736.30 (SW) 45.95 / �� /I I I I I III \\ \' /////11 Ill I 111 1 1 1 1 1 1 1 1 I I I I I I I I I I I I I I I I 2736.40 (W) �I I I I III I III I IIII IIIII I I III III I I 1I I1 1I1 11I 1 1 1 I I I I I I IIIIII II CONTECH STORMFILTER 2735.10 (E)ST 10 �61 I II ST 8 RIM 2742.05 2734.60 (W)3. SEE EROSION CONTROL PLANS S SHEET WATER QUALITY UNIT* 4 REGARDING PHASING OF THE WORK �, l ,✓I I I Illl \ �� - I► IIII, 111°II I to I I 1 1 IIIIIIII I 4S I I I I I I I \ 1 1 IIII 11^ I I 1 1 I I I \l l ST 9 RIM = 2741.54 2737.75 (W) II \\ I IIII ICI I I I I I I I I I I I I I I I COCNRETE HEADWALL SPECIFIC TO PROTECTING THE EXISTING / / 1 IIIII \ _ ,X I I I (IIIIIIIII I �' I I I I �; I I I I I I I IIII 11 I I I \ (30" PIPE) I � 1 - - \ � � III IIII IIII ' I I 1 1 N 1 1 1 1 1 1 1 I III � \ III STREAM. / >,� I II11 1 _ I I I I I IIII I I II I \ III I I \ 1 I I I1 ST 10 JUNCTION BOX RIM = 2744.33 2737.62 (E) 2737.52 (S) �, � II II11 � _ - \l�. I � � � II11111 I I I I i I I I I I I 1 1 11 1 1 1 1 llllll ST 11 OPEN THROAT INLET RIM = 2740.73 2736.07 (N) 1// II \\\\\\\` I I 11 1 I I I I I \ I I I I I I I _ / 1 I I I \ \ \ I I I I I I I I � ST 12 CONTECH UNDERGROUND" RIM = 2741.60 2735.10 (N) 2735.10 (W) W DETENTION SYSTEM 1\\\ \ \ II I I I I I I I I N \ IIIIIIIII `DETAILS FOR CONTECH SYSTEM (WATER QUALITY UNIT S UNDERGROUND \\ \ IIIIIIIIIIII DETENTION SYSTEM) ARE INCLUDED WITH THE CONSTRUCTION PLANS "SEE DETAIL THIS SHEET (LOWER-RIGHT) O �I I , � ` ��� \\\\\\\\\ \\ \\\\\\\\\ \ \ I I IIIIIIIII Wl ,4 I I I \ \ i 1 d o I I I \ \\ \\\\ 1 STORM PIPES p ����� I I I I IIIIIIIIII I NAME RUN SIZE LENGTH (FT) SLOPE MATERIAL � � / I / \ \�\\\ \ \ \\\\\\\\\\\ IIIIII I I I I I I I I I I I I II ST A ST 1-ST 2 8" 95 2.22% HDPE z \ / l IIIII \ \ � r\` �� ° \\ \\\\ 1 I I I I ST B ST 2-ST 3 8 2 5.29/° HDPE O O III l/ l \ \�\ \\\\\\\\\ \\\\\\\\\\\ \\ \ \ \\\\ 1 \ J U \ ST 11 / - _ - NEW RETAIL STORE \ / / \ \\\\\\\\\ \\\\\\\\\\\\ \\\ \ \\\\ \\\\�\ \ I ST C ST 3-ST 4 18" 45 5.23% HDPE J Q - vvvvw- \ ( f PROTOTYPE "F" j / i \\ \ \\ \\\\ \ \\\\\\\\\\\\\\\\ \\\ \\ \\ \\N ST G ST 3-ST 7 18" 25 3.44% HDPE a Z \ \_ F.F.E.- 2744.50 0 J \ \\\\\ \\\\\\\\\\\\ \\ \\ \ \ STD ST 4-ST 5 18" 9 5.40% HDPE I 1 I\ \\\\\ ; ST ST 18" 4 0.50% RCP V > \\\\ \\ \\\\ \, Z z Mco \ -�> I 11 I 111111 I IIIIII111\ \\ \ ° 0 N CuR "I \ 1 I I / i 4q I IIIIII III IIIIIII I I1111 \ \o \ \ \` ` ST F ST 6-ST 7 18 64 0.50% HDPE LL Q 0 Q / \ � � � IIIIIII m N 11 I IIII IIIII IIIIII �I \ \\\ \\\ \\ � � - STH ST 7- 18" 14 8.38% HDPE 0 1z / II I I Q ° cu N I v, \ III I I I IIII IIII 11 111 cn\ \\\\ \\\ L ST ST 8-ST 5 18 33 0.87/ HDPE Z w O W �- / Boor ROOF DRAINS TO ` ` III III IIIIIIIII\111 _ ; ° Q N 8" HDPE (APPROXIMATELY \ IIIIIII I I I I I11 1 N 11 1\\\ \\\\\\ ST J ST 9-ST 10 30" 25 0.52% RCP J m m (� / 133LF 0.50% MIN. \ I I 11 II III\ 11 11\111\ _� _ a @ ) I I III I11\It 1\\\\t I II I\ \ \ \\\` ST K ST 10-ST E 30" 85 1.70% RCP Z = CI Z O X c/ 1 \ II 1 - _ O O ° \ I \ 11111111\\IIIII\\ \\ � \ Z N I �� \\ \\ I I 1\\1 \I \\IIII\�11\11�1 II \ \\� Q V a O - -1U LLQ \\ I \ ST1 \ \ \ ���, \ I \ \\ \ \11111111j111\ �� - ~ C� cn \�\ o \ \ \ \\ \ \\\\\\1 111 IIII\ Q 2 Z \ \ \ \ \ \ \ 1 11 Z �- \� O sg„NopF \ \ \\ \ \ \ sTB a D o T \ \ \ , ss � 1 \ \\ \ \ \ � ' / DIVERSION WEIR 2ST 4 ST 2 2743 \\ \\\ \\`\ R / ST B ST 7 \\\\\\\\\ ��`ps' '•���y'.� ST 5 STD STC STG N� \\ \\\\\\\\\�\\\ \ _ EA < ST E ST I ST 3 \ >4 �W \\\\\\\\ \ \\ \� � STC •a 365 ' STG •GIN•. ST 8 \ ST 12 REVISIONS: TRENCH I.E.= 2740.00 2j41 \ \\�� - - - PLAN � \ r p � ST 6 I I\ TOP - 2743.06 DRAWN BY: BBAILEY 6 70 LF NE - TRENCH GRATE O I i \ FIELD DATE: 01.01.2016 � I O' (DETAIL, SHEET 9) �\ I I \ OFFICE DATE: 04.05.2017 \ CHECKED BY: JCARGILE N 61• °yF \ I TRENCH LE.= 2737.89 C _\ WEIR = 2740.10_ _ _ PLOT DATE: 19.04.2017 o 57 LF NEW TRENCH GRATE Z (DETAIL, SHEET 9) C TRENCH LE.= 2737.84 m 0� Rl/`>;i' ST C / \I ST G 0 20' 40' o \ I I 0 z I w I m 0 PROFILE SHEET Q Q 10 STRUCTURE ''ST 3'' DETAIL NOT TO SCALE Z w u PROJECT NO.: 16-137