Loading...
HomeMy WebLinkAboutNC0085359_Compliance Evaluation Inspection_20170406Water Resources Environmental Quality April 6, 2017 Mr. Edward Goscicki, PE Union County Department of Public Works 500 North Main Street, Suite 600 Monroe, NC 28112 SUBJECT: Compliance Evaluation Inspection Twelve Mile Creek WWTP NPDES Permit NCO085359 Union County, NC Dear Mr. Goscicki: ROY COOPER Governor MICHAEL S. REGAN Secretory S. JAY ZIMMERMAN Director RECEIVEDINC®EUDWR APP -1 0 7011 pard iflossullor On April 3, 2017, Roberto Scheller of this Office conducted a compliance inspection at the subject facility. This inspection was conducted as a Compliance Evaluation Inspection (CEI) to insure compliance with permit requirements and conditions. At the time of inspection facility appeared to be well maintained and operated. We wish to thank you and the operating staff for assistance regarding this inspection. The enclosed report should be self-explanatory; however, should you have any questions, please do not hesitate to contact myself or Roberto Scheller at (704) 235-2204 or robert6.scheller@ncdenr.gov. Sincerely, W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Division of Water Resources, NCDEQ Enclosed cc: Henry Eudy, ORC, email: heudy@charlottenc.gov Wastewater- Branch File —:7 --Nothing Compares::--,. State of North Carolina I Environmental Quality 1611 Mail Service Center I Raleigh, North Carolina 27699-1611 919-707-9000 United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 i, i 2 15 i 3 I NC0085359 I11 12 17/04/03 17 18 i i 19 i G i 201 I 21111111IIIIIIIIIIIIIIIIIIIIIIIIIIIIIII11111 f6 Inspection Work Days Facility Self -Monitoring Evaluation Rating 131 QA - Reserved ----- 67 70 JLJ j 71 L] 72 i �, i 731 I X 74 751 III I � 180 L-1 I I I Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 10:09AM 17/04/03 15/01/01 Twelve Mile Creek WWTP Exit Time/Date Permit Expiration Date 8299 Kensington Dr Waxhaw NC 28173 01:29PM 17/04/03 19/12/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Henry Harrison Eudy/ORC/980-214-5977/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Edward Goscicki,500 N Main St -Ste 500 Monroe NC 281124730/Executive Director/704-296-421217042964232 No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenance Records/Reports. Self -Monitoring Program Sludge Handling Disposal Facility Site Review Effluent/Receiving Waters Laboratory . Section D: Summary of Finding/Comments (Attach additional sheets,of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Roberto Scheller MRO WQ//252-946-6481/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date W. Corey Basinger MRO WQ//704-235-2194/ EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type 31 NCO085359 I11 12 17/04/03 17 18 ICI Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Page# Permit: NCO085359 Owner - Facility: Twelve Mile Creek WWTP Inspection Date: 04/03/2017 Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ 0 ❑ application? ■ ❑ ❑ ❑ Is the facility as described in the permit? ❑ N ❑ ❑ # Are there any special conditions for the permit? 0 ❑ ❑ ❑ Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? N ❑ ❑ ❑ Comment: Sand filters have been removed and replaced with fabric filters. Current permit expires on December 31, 2019. Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? 0 ❑ ❑ ❑ Is all required information readily available, complete and current? ■ ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? E ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? 0 ❑ ❑ ❑ Is the chain -of -custody complete? 0 ❑ ❑ ❑ Dates, times and location of sampling available for review. Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses ❑ Transported COCs N Are DMRs complete: do they include all permit parameters? 0 ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator N ❑ ❑ ❑ on each shift? Is the ORC visitation log available and current? E ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? E ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility classification? ■ ❑ ❑ ❑ Is a copy of the current NPDES permit available on site? E ❑ ❑ ❑ Facility has copy of previous year's Annual Report on file for review? ❑ ❑ ❑ N Comment: DMR's reviewed from 3-2015 to 11-2016 reporting errors noted for correction. Records were available for review. Influent Sampling # Is composite sampling flow proportional? Yes No NA NE 0 ❑ ❑ ❑ Page# 3 Permit: NC0085359 Owner -Facility: Twelve Mile Creek WWTP Yes No NA NE Type of bar screen Inspection Date: 04/03/2017 Inspection Type: Compliance Evaluation a.Manual ❑ Influent Sampling Yes No NA NE Is sample collected above side streams? b.Mechanical ❑ ❑ ❑ Is proper volume collected? 0 ❑ ❑ ❑ Is the tubing clean? N ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees N ❑ ❑ ❑ Celsius)? Is the unit in good condition? E ❑ ❑ Is sampling performed according to the permit? N ❑ ❑ ❑ Comment: Influent sampler appeared in good condition with sample storage temperature noted at 4 degree C. Bar Screens Yes No NA NE Type of bar screen a.Manual ❑ b.Mechanical Are the bars adequately screening debris? ❑ ❑ ❑ Is the screen free of excessive debris? N ❑ ❑ ❑ Is disposal of screening in compliance? 0 ❑ ❑ ❑ Is the unit in good condition? E ❑ ❑ ❑ Comment: Bar screen was in operation at time of inspection and appeared to be veru marginal in screening debris removal. Debris is removed for disposal at county landfill. Pump Station - Influent Yes No NA NE Is the pump wet well free of bypass lines or structures? 0 ❑ ❑ ❑ Is the wet well free of excessive grease? ❑ ❑ ❑ 0 Are all pumps present? ❑ ❑ ❑ Are all pumps operable? E ❑ ❑ ❑ Are float controls operable? E ❑ ❑ ❑ Is SCADA telemetry available and operational? N ❑ ❑ ❑ Is audible and visual alarm available and operational? ❑ ❑ E ❑ Comment: Grit Removal Type of grit removal a.Manual b.Mechanical Yes No NA NE El 0 Page# 4 U Permit: NCO085359 Inspection Date: 04/03/2017 Owner - Facility: Twelve Mile Creek WVVTP Inspection Type: Compliance Evaluation Are the aerators operational? N ❑ Grit Removal Yes No NA NE Is the grit free of excessive organic matter? 0 ❑ ❑ ❑ Is the grit free of excessive odor? N ❑ ❑ ❑ # Is disposal of grit in compliance? E ❑ ❑ ❑ Comment: Grit is disposed of in County Landfill. Oxidation Ditches Yes No NA NE Are the aerators operational? N ❑ ❑ ❑ Are the aerators free of'excessive solids build up? 0 ❑ ❑ ❑ # Is the foam the proper color for the treatment process? 0 ❑ ❑ ❑ Does the foam cover less than 25% of the basin's surface? 0 ❑ ❑ ❑ Is the DO level acceptable? ❑ ❑ ❑ Are settleometer results acceptable (> 30 minutes)? ❑ ❑ ❑ Is the DO level acceptable?(1.0 to 3.0 mg/1) 0 ❑ ❑ ❑ Are settelometer results acceptable?(400 to 800 ml/I in 30 minutes) 0 ❑ ❑ ❑ Comment: Three of four oxidation ditches were in operation. One ditch was down for construction. Eash train is equiped with anaerobic and anoxic zones. It was noted that rags and debris was collecting on mixers. Nutrient Removal # Is total nitrogen removal required? # Is total phosphorous removal required? Type # Is chemical feed required to sustain process? Is nutrient removal process operating properly? Comment: Sodium aluminate added at secondary clarifier for phosphorus removal. Chemical Feed Is containment adequate? Is storage adequate? Are backup pumps available? Is the site free of excessive leaking? Comment: Secondary Clarifier Yes No NA NE ■ ❑ ❑ ❑ M ❑ ❑ ❑ Chemical • ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ ■ ■ ❑ ❑ ❑ Yes No NA NE Page# 5 Permit: NC0085359 Owner - Facility: Inspection Date: 04/03/2017 Inspection Type: Twelve Mile Creek WVVTP Compliance Evaluation • few suspended sloids. Effluent from #1 and #2 Clarifiers was clear with few suspended Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? 0 ❑ ❑ ❑ Is the site free of excessive buildup of solids in center well of circular clarifier? E ❑ ❑ ❑ Are weirs level? N ❑ ❑ ❑ Is the site free of weir blockage? 0 ❑ ❑ ❑ Is the site free of evidence of short-circuiting? N ❑ ❑ , ❑ Is scum removal adequate? 0 ❑ ❑ 0 Is the site free of excessive floating sludge? E ❑ ❑ ❑ Is the drive unit operational? 0 ❑ ❑ ❑ Is the return rate acceptable (low turbulence)? N ❑ ❑ ❑ Is the overflow clear of excessive solids/pin floc? E ❑ ❑ ❑ Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth) 0 ❑ . ❑ ❑ Comment: Three of four secondary clarifiers were in operation. Effluent from #5 Clarifier was clear with • few suspended sloids. Effluent from #1 and #2 Clarifiers was clear with few suspended ❑ ❑ • solids. ❑ ❑ M ❑ Pumps -RAS -WAS Yes No NA NE Are pumps in place? 0 ❑ ❑ ❑ Are pumps operational? 0 ❑ ❑ ❑ Are there adequate spare parts and supplies on site? 0 ❑ ❑ ❑ Comment: Filtration (High Rate Tertiary) Type of operation: Is the filter media present? Is the filter surface free of clogging? Is the filter free of growth? Is the air scour operational? Is the scouring acceptable? Is the clear well free of excessive solids and filter media? Yes No NA NE Cross flow • ❑ ❑ ❑ • ❑ ❑ ❑ M ❑ ❑ ❑ ❑ ❑ M ❑ M ❑ ❑ ❑ M ❑ ❑ ❑ Comment: Sand filters removed and replaced with drum filters. Efflunt clear with no visible suspended solids. Disinfection - UV Are extra UV bulbs available on site? Are UV bulbs clean? Yes No NA NE N ❑ ❑ ❑ ■ ❑ ❑ ❑ Page# 6 0 Permit: NCO085359 Owner - Facility: Twelve Mile Creek WwrP # Is flow meter used for reporting? 0 ❑ ❑ Inspection Date: 04/03/2017 Inspection Type: Compliance Evaluation 0 ❑ ❑ ❑ Disinfection - UV Yes No NA NE Is UV intensity adequate? ❑ ❑ ❑ E Is transmittance at or above designed level? 0 ❑ ❑ ❑ Is there a backup system on site? 0 ❑ ❑ ❑ Is effluent clear and free of solids? 0 ❑ ❑ ❑ Comment: 2 UV units on site with the older of the two units being used as back up. Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? 0 ❑ ❑ ❑ Is flow meter calibrated annually? 0 ❑ ❑ ❑ Is the flow meter operational? 0 ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ ❑ 0 Comment: Facility is equiped with rectangular weir and ultra sonic flow meter. It ws noted that flow is ❑ ❑ passing under weir plate Operator indicated that flow measurment structure is scheduled # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees 0 for replacement as part of construction upgrades to plant. ❑ ❑ Celsius)? Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ❑ ❑ ❑ Is sample collected below all treatment units? 0 ❑ ❑ ❑ Is proper volume collected? E ❑ ❑ ❑ Is the tubing clean? 0 ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees 0 ❑ ❑ ❑ Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type N ❑ ❑ ❑ representative)? Comment: Effluent sampler appeared to be well maintained with sample storage at 3 degrees C Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? 0 ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? 0 ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ ■ ❑ Comment: Effluent was clear with on visible suspended solids. Foam was being generated at discharge but disipated within 50 downstream. Upstream/ Downstream Sampling Yes No NA NE Page# 7 Permit: NCO085359 Owner - Facility: Twelve Mile Creek WWfP. Inspection Date: 04/03/2017 Inspection Type: Compliance Evaluation Upstream / Downstream Sampling Yes No NA NE Is the facility sampling performed as required by the permit (frequency, sampling type, and E ❑ ❑ ❑ sampling location)? Comment: Aerobic Digester Yes No NA NE Is the capacity adequate? 0 ❑ ❑ ❑ Is the mixing adequate? .0 ❑ ❑ ❑ Is the site free of excessive foaming in the tank? E ❑ ❑ ❑ # Is the odor acceptable? N ❑ ❑ ❑ # Is tankage available for properly waste sludge? 0 ❑ ❑ ❑ Comment: Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? E ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable E ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Standby Power Yes No NA NE Is automatically activated standby power available? N ❑ ❑ ❑ Is the generator tested by interrupting primary power source? N ❑ ❑ ❑ Is the generator tested under load? E ❑ ❑ ❑ Was generator tested & operational during the inspection? ❑ ❑ ❑ N Do the generator(s) have adequate capacity to operate the entire wastewater site? 0 ❑ ❑ ❑ Is there an emergency agreement with a fuel vendor for extended run on back-up power? 0 ❑ ❑ ❑ Is the generator fuel level monitored? N ❑ ❑ ❑ Comment: Page# 8 f