NC0085588_Compliance Evaluation Inspection_20170324
Water Resources ENVIRONMENTAL QUALITY Mr. Brent Dueitt, General Manager II Regional Stations Duke Energy Carolinas. LLC 253 Plant Allen Road Belmont, NC 28012 Dear Mr. Dueitt: March .24, 2017 ROY COOPER Govemor MICHAEL S. REGAN . Secretary S'. 7'AY-ZIMMEkMAN Director RECEIVEDINCDEQIDWR MAR 2 8 2017 WaterQuality, Subject: Compliance Evaluation Inspect omion$eo�gSeCt�0n Duke Energy Allen Steam Station NPDES Permit No. NCO085588 Lincoln County Enclosed is a copy of the Compliance Evaluation Inspection for the inspection conducted, at the subject facility on March 22, 2017, by Ori Tuvia and Brandy Costner. Michael Gantt's cooperation during the site visit was much appreciated. Please advise the staff involved with this NPDES Permit by forwarding a copy of the enclosed report.' As was discussed during the inspection, DMRs must indicate all certified labs used for the sampling done for that month's DMR. The report should be self-explanatory; however, should you have any questions concerning this report, please do not hesitate to contact Ori Tuvia at (704) 235-2190, or at ori.tuvia@ncdenr.gov. Sincerely, Ori Tuvia, Environmental Engineer Mooresville Regional Office Division of Water Resources, DEQ Cc:.,, NPDES Unit Gaston County Health Department MRO Files Mooresville Regional Office Location: 610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-16991 Fax: (704) 663-60401 Customer Service: 1.877-623-6748 United States Environmental Protection Agency FormApproved. t rH Washington, D.C_ 20460 OM B N o. 2040-0057 .Water_Comp.liance Inspection Report Approval expires8-31=0e_�__ Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr1mo,1day Inspection Type Inspector Fac Type 1 IN ' 2 16 1 3 I NCQ004s7s 111 12 1 17/06/22 17 18 1 n i 19 I s I 201 1 211/1111 111111111.111111111 1 111111 11111111111 (66 1 Inspection Work Days Facility Seff-Monitoring Evaluation Rating B1 QA Reserved 67 1.0 7014 I 71 lr� 1 72 i � 1 731 1 174 751 I 1 1 I 1 ( 180 LJ �J Section B: FacilityDataL� Name and Location of Facility Inspected (For Industrial Users discharging to POTW_, also include Entry Time/Date Permit Effective Date POTW name and NIP DES permit Number) 10:05AM 17/03/22 1 Uo3/o1 Plant Allen Steam Station 253 Plant Allen Rd Exit TimelDate Permit Expiration Date Belmont NC 28012 02:00PM 17/03/22 15105/31 Name(s) of Onsite Representative(s�Tities(s)/Phone and Fax Number(s) Other Facility Data 81 Michael R Gantt/ORC/704-829-2587/ Name, Address of Responsible Offrcial/Tille/Phone and Fax Number Contacted Alien Stowe,526 S Chruch St Charlotte NC 282011002/704-382-4309/7043829840 No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenance Records/Reports Self -Monitoring Program Sludge Handling Disposal Facility Site Review EffluentfReceiving Waters Laboratory Sectioh D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(S) and Signature(s) of inspectors) Agency/Office/Phone and Fax Numbers Date, Ori A Tuvia MRO WQ/17D4-663-16991 2oj_;L Signature of Management Q A Fleviewer Agency/Office/Phone and Fax Numbers ' Date Andrew Pitner�W�MRO WQ//704-663-1699 Ext.21 EPA Form 356Q-3 (Rev 9-94) Previous editions are obsolete. Page# 1 NPDES yr/mo/day Inspection Type 1 3I NCO004979 I11 121 17/03122 j 17 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary Brandy Costner was a secondary inspector Page# Permit: NCO004979 Owner -Facility: Plant Allen Steam Station Inspection Date: 03/2212097 Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new M ❑ ❑ ❑ - - application? --. Is the facility as described in the permit? ■ ❑. ❑ ❑ # Are there any special conditions for the permit? M ❑ ❑ ❑ Is access to the plant site restricted to the general public? M ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? ■ ❑ ❑ ❑ Comment: The Division received the permit renewal package on 10/15/2014. No chlorination is added to Outfalls 001. 003, and 004 Record Keeping Yes No NA NE. 'Are records kept and maintained as required by the permit? ■ ❑ ❑ ❑ Is all required information readily available, complete and current? M ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? M ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? M 11110 Is the chain -of -custody complete? M ❑ ❑ ❑ Dates, times and location of sampling Name of individual performing the sampling ■ Results of analysis and calibration Dates of analysis ■ Name of person performing analyses ■ Transported COCs Are DMRs complete: do they include all permit parameters? ■ ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ M ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator ❑ ❑ ■ ❑ on each shift? Is the ORC visitation log available and current? M ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? M ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility classification? ■ ❑ ❑ ❑ Is a copy of the current NPDES permit available on site? ■ ❑ ❑ ❑. Facility has copy of previous year's Annual Report on file for review? ❑ ❑ 0 ❑ Comment: The records reviewed during the _inspection were ortaanized and well maintained DMRs COCs, ORC Jogs and calibration Iotas were reviewed for the period. February 2016 through January 2017: No limit violations were reported and all monitoring frequencies were correct. ORC must indicate on future DMRs all certified labs used for the sampling done for that months DMR. Page# 3 Permit: NC0004979 Owner - Facility: Plant Allen Steam Station Inspection Date: 0312212017 Inspection Type:. Compriance &81uat€on Yes No NA NEE # Is composite sampling flow proportional? ❑ ❑ Laboratory . - _. Yes .No. NA NE Are field parameters performed by certified personnel or laboratory? I ❑ '❑ ❑ Are all other perameters(excluding field parameters) performed by a certified lab? M ❑ ❑ ❑ # Is the facility using a contract lab? ❑ ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees ❑ ❑ ❑ ❑ Celsius)? Incubator (Fecal Coliform) set to 44,5 degrees Celsius+/- 0.2 degrees? 110 0 ❑ Incubator (BOD) set to 20.0 degrees Celsius +1-1.0 degrees? ❑ ❑ "M ❑ Comment: The facility is certified to perform on-site field analyses (PH and temperature) under laboratory certification #5134. The remaining permit -required effluent analyses are performed by Duke Enemy's Environmental Services Laboratory (Certification #248) and the contracted services of Prism Labs (low level mercury) and ETS. Inc, (toxicity). Influent Sampling Yes No NA NEE # Is composite sampling flow proportional? ❑ ❑ M ❑ Is sample collected above side streams? I ❑ ❑ ❑ Is proper volume collected? M ❑ ❑ ❑ Is the tubing clean? ❑ ❑ M ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees ❑ ❑ M ❑ Celsius)? Is sampling performed according to the permit? M ❑ 1111 ❑ Comment: The subject permit requires grab samples at the internal Outfall 005 (FGD treatment system effluent) prior to entering the ash basin. . Comment: The subject permit requires effluent arab samples. Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ❑ ❑ ❑ Is sample collected below all treatment units? ❑ ❑ ❑ Is proper volume collected? t ❑ ❑ ❑ Is the tubing clean? ❑ ❑ M ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees ❑ ❑ ■. ❑ Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type . ■ ❑ ❑ ❑ representative)? Comment: The subject permit requires effluent arab samples. Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? ! 0011 Page# 4 • Permit: N00004979 Owner -Facility: Plant Allen Steam Station Yes No NA NE Is containment adequate? 0 Inspection Date: 03122/2017 Inspection Type: Compliance Evaluation ❑ ❑ Is storage adequate? Operations & Maintenance Yes No NA WJE Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ■ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? ❑ Is the site free of excessive leaking? ■ ❑ _Comment: The facility was not Generating electricity at the time of the inspection. The ash basin and ❑ Comment: Emergency response plan, including the chemical feed storage, was last updated FGD wastewater treatment system (WWTS) appeared to be properly operated and well ❑ ❑ 2/28/2017 maintained. The FGD WWTS is connected to a computer monitoring system to assist the ❑ ❑ on-site staff in the operation of the treatment units/processes. ❑ ❑ ❑ Equalization Basins Yes No NA NE Is the basin aerated? ❑ ❑ 0 ❑ Is the basin free of bypass lines or structures to the natural environment? ■ ❑ -❑ ❑ Is the basin free of excessive grease? ■ ❑ 110 Are all pumps present? ■ ❑ ❑ ❑ Are all pumps operable? ❑ ❑ ❑ Are float controls operable? M ❑ . 110. Are audible and visual alarms operable? ❑ ❑ M ❑ # Is basin size/volume adequate? N ❑ 110 Comment: Chemical Feed Yes No NA NE Is containment adequate? 0 ❑ ❑ ❑ Is storage adequate? ❑ ❑ ❑ Are backup pumps available? M ❑ ❑ ❑ Is the site free of excessive leaking? ■ ❑ ❑ ❑ Comment: Emergency response plan, including the chemical feed storage, was last updated on ❑ ❑ ❑ 2/28/2017 M ❑ ❑ ❑ Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? 0 ❑ ❑ ❑ Is the site free of excessive buildup of solids in center well of circular clarifier? ❑ ❑ ❑ Are weirs level? ■ ❑ ❑ ❑ Is the site free of weir blockage? ❑ ❑ ❑ Is the site free of evidence of short-circuiting? M ❑ ❑ ❑ Is scum removal adequate? M ❑ ❑ ❑ Is the site free of excessive floating sludge? ❑ ❑ ❑ Is the drive unit operational? ■ ❑ ❑ ❑ Page# 5 Permit: NC0004979 Owner-Facillty: Plant Allen Steam Station # Is flow meter used for reporting? ■ ❑ Inspection Date: 03122/2017 Inspection Type: ComplianceEvaluation Is flow meter calibrated annually? ❑ Sec©ndary Giarifier '.w... 'Yes No NA NE Is the return rate acceptable (low turbulence)? M ❑ ❑ ❑ Is the overflow clear of excessive solids/pin floc? M ❑ ❑ ❑ Is the sludge blanket level acceptable? (Approximately 1/4 of the sidewall depth) t ❑ ❑ ❑ Comment: Flow Measurement - InNent ices No NA NE # Is flow meter used for reporting? ■ ❑ ❑ ❑ Is flow meter calibrated annually? ❑ ❑ ❑ Is the flow meter operational? ■- ❑ ❑ ❑ (if units are separated) Does the chart recorder match the float meter? ❑ ❑ s ❑ Comment: The FGD WWTS effluent is measured by an in-line flow meter. The flow meter. is calibrated/verified annually and was calibrated/verified on 3/23/20.16 by the'on-site on-site landfill equipped with a liner and leachate collection system. wastewater staff. The Ary ash and sluiced ash (removed from the ash basin treatment system) are also Solids Handling Equipment Yes No NA NE Is the equipment operational? ■- ❑ ❑ ❑ Is the chemical feed equipment operational? M ❑ ❑ ❑ Is storage adequate? M ❑ ❑ ❑ Is the site free of high level of solids in filtrate from filter presses or vacuum filters? ❑ ❑ ❑ 0 Is the site free of sludge buildup on belts and/or rollers of filter press? ❑ ❑ ❑ 0 Is the site free of excessive moisture in belt filter press sludge cake? ❑ ❑ ❑ The facility has an approved sludge management plan? ■ ❑ '❑ ❑ Comment: The FGD WWTS is equipped with three operational filter presses; however, these units were not in service at the time of the inspection. The dewatered sludge is transported to the on-site landfill equipped with a liner and leachate collection system. The Ary ash and sluiced ash (removed from the ash basin treatment system) are also disposed into the on-site landfill. The oypsurn material from the FGD system is reused W an outside company (National Gypsum) in the dry wall market. Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? ❑ ❑ W ❑ Is flow meter calibrated annually? ❑ 0011 Is the flow meter operational? ❑ ❑ 0 11 (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ 0 ❑ Page# 6 E Permit: NG0004979 Owner -Facility: Plant Allen Steam Station Inspection.Date: 0312212017 Inspection Type: Compliance Evaluation Flow Measurement -Effluent Yes No NA NE Comment: Flow measurements for Outfalls 001.003. and 004 are based on pump curvesAocis. Outfall 002 discharges are measured by a staff guacie/ultrasonic level indicator and weir. The ORC verifies the Outfall 002 flow measurement system annually. Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? ■ ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? ' ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ 0 ❑ Comment: No discharges were observed from Outfalls 002A. 0028 and 005 (internal) at the time of the inspection. The effluents from Outfalls 001, 002, 003and 004 effluents were clear with no floatable solids or foam. The receiving stream did not appear to be negatively impacted. Page# 7