Loading...
HomeMy WebLinkAbout20100899 Ver 3_More Info Letter_20170309K; Ira. Water Resources Environmental Quality March 9, 2017 Clearwater Paper Corporation Attn: Brian Hoaglund 601 W. Riverside Ave Spokane WA 99201 Subject: REQUEST FOR ADDITIONAL INFORMATION Clearwater Paper Corporation Cleveland County Facility Expansion Dear Mr. Hoaglund: ROY COOPER Governor MICHAEL S. REGAN Secretary S. JAY ZIMMERMAN Director DWR # 2010-0899 v3 Cleveland County On February 3, 2017, the Division of Water Resources — Water Quality Programs (Division) received your application dated January 31, 2017, requesting an Individual Water Quality Certification from the Division for your project. The Division has determined that your application is incomplete and cannot be processed. The application is on -hold until all of the following information is received: 1. If the U.S. Army Corps of Engineers requests a response to any comments received as a result of the Public Notice, please provide the Division with a copy of your response to the USACE. [15A NCAC 02H .0502(c)] Pursuant to 15A NCAC 02H.0506(a) a 401 Water Quality Certification may only be issued upon determining that existing uses are not removed or degraded by a discharge to classified surface waters. Based on the information provided in the application and associated documents, all surface flow from the drainage area to Impact #2 will be replaced with impervious area that is proposed to be rerouted through a stormwater control measure. The discharge/outlet from the measure is proposed to be located a significant distance downstream. In addition, all surface flow from the drainage area to Impact #3 will be replaced with impervious area that is proposed to be rerouted through a stormwater control measure and the discharge/outlet from the measure will be directed to another stream. The rerouting of the drainage areas and surface flows has the potential to remove existing hydrology and therefore remove existing uses within these stream channels from the impact limits to the proposed stormwater outlet location/confluence with another stream channel. Please provide a thorough analysis and any additional information relative to this issue for further review by the Division. State of North Carolina I Environmental Quality 450 W. Hanes Mill Road, Suite 300, Winston-Salem, North Carolina 27105 Phone: 336-776-98001 FAX: 336-776-9797 Clearwater Paper Corporation DWR# 2010-0899 v3 Request for Additional Information Page 2 of 3 Please provide more details regarding avoidance and minimization of the impacts for this project. [15A NCAC 02H .0506(f) and (g)]. This Office believes that the area within the northeast corner of the development labeled on the plans as parking can be moved or reconfigured uitilizing adjacent upland on adjacent property to the southwest that was evaluated at early stages within this proposal in order to avoid or minimize impacts #3 and impacts #4. Please revise the plans to avoid the impacts or provide a detailed explanation of why this plan for the activity cannot be practically accomplished, reduced or reconfigured. 4. Please clarify whether the Division of Energy, Mineral and Land Resources will require riprap within any stream channels or wetlands as part of the Erosion & Sedimentation Control Plan approval. If riprap is required, please enumerate and clearly label the temporary and permanent impacts on the site plan and submit a channel restoration detail. Riprap must be located below the stream bed elevation. [15A NCAC 02H .0506(f) and (g)] 5. For the impacts within the utility corridors, some of the proposed stream crossings are not aligned as perpendicular crossings. Please re -configure your proposed stream crossings to show it aligned approximately perpendicular (between 75° and 105°) to the stream or provide justification for any non -perpendicular crossings. [15A NCAC 02H .0506(b)(2)] 6. Please provide a detailed engineering plan, profile view, and cross-section of all proposed culverts. These drawings must include details regarding stream alignment in relation to pipe alignment, pipe slope, pipe burial, and dissipater pad. [15A NCAC 02H .0502(b)] 7. All work must be done "in the dry" to protect downstream water quality, therefore dewatering methods will be necessary to temporarily dewater the stream channel during pipe installation. Please provide a construction sequence that details the method of dewatering to be utilized at the site and the sequence of construction events to be followed to ensure compliance with this condition. In addition, please ensure that the location of the temporary impacts are shown on the construction drawings and clearly indicated in a revised impact table. [15A NCAC 02H .0502(b)(3)] 8. Please provide a complete Stormwater Management Plan for this project. A complete SMP shall include: Stormwater management shall be provided throughout the entire project area in accordance with 15A NCAC 02H .1003. For the purposes of 15A NCAC 02H .1003(2)(a), density thresholds shall be determined in accordance with 15A NCAC 02H .1017 A full-sized plan sheet showing the entire site with its storm drainage system, including every inlet, outlet and conveyance device. Please show how stormwater management requirements have been met at every proposed outlet location. [15A NCAC 02H .0506(b)(5) and (c)(5)] c. All appropriate stormwater control measure (SCM) supplemental forms and associated items, that complies with the high density development requirements of 15A NCAC 02H .1003. Clearwater Paper Corporation DWR# 2010-0899 v3 Request for Additional Information Page 3 of 3 Pursuant to Title 15A NCAC 02H .0502(e), the applicant shall furnish all of the above requested information for the proper consideration of the application. If all of the requested information is not received in writing within 30 calendar days of receipt of this letter, the Division will be unable to approve the application and it will be returned. The return of this project will necessitate reapplication to the Division for approval, including a complete application package and the appropriate fee. Please respond in writing within 30 calendar days of receipt of this letter by sending two copies of all of the above requested information to my attention at the address below. Please be aware that you have no authorization under the Water Quality Certification Rules for this activity and any work done within waters of the state may be a violation of North Carolina General Statutes and Administrative Code. Please contact me at 336-776-9693 or Sue. Homewood@ncdenr.gov if you have any questions or concerns. Sincerely, Sue Homewood Winston-Salem Regional Office cc: R. Clement Riddle, Clearwater Environmental Consultants (via email) David Shaeffer, USACE Charlotte Regulatory Field Office (via email) DWR MRO 401 files DWR 401 & Buffer Permitting Unit