HomeMy WebLinkAbout20170257 Ver 1_2 B-5556 Wake PCN_20170306Q�oF wA rF9Qc
� Y
� �
i7 Y
Office Use Only:
Corps action ID no.
DWQ project no.
Form Version 1.4 January 2009
Pre-Construction Notification (PCN) Form
A. Applicant Information
1. Processing
1 a. Type(s) of approval sought from the Corps: ❑X Section 404 Permit Section 10 ❑ rmit
1b. Specify Nationwide Permit (NWP) number: �2 or General Permit (GP) number:
1 c. Has the NWP or GP number been verified by the Corps? ❑ Yes ❑X No
1 d. Type(s) of approval sought from the DWQ (check all that apply):
❑X 401 Water Quality Certification — Regular ❑ Non-404 Jurisdictional General Permit
❑ 401 Water Quality Certification — Express ❑X Riparian Buffer Authorization
1 e. Is this notification solely for the record For the record only for DWQ For the record only for Corps Permit:
because written approval is not required? 401 Certification:
❑ Yes ❑X No ❑ Yes ❑X No
1f. Is payment into a mitigation bank or in-lieu fee program proposed for
mitigation of impacts? If so, attach the acceptance letter from mitigation bank � Yes ❑X No
or in-lieu fee program.
1 g. Is the project located in any of NC's twenty coastal counties. If yes, answer 1 h � Yes ❑X No
below.
1 h. Is the project located within a NC DCM Area of Environmental Concern (AEC)? ❑ Yes ❑X No
2. Project Information
2a. Name of project: Replacement of Bridge No. 910490 on Lake Dam Road over Walnut Creek
2b. County: Wake County
2c. Nearest municipality / town: Raleigh, NC
2d. Subdivision name: not applicable
2e. NCDOT only, T.I.P. or state project no: B-5556
3. Owner Information
3a. Name(s) on Recorded Deed: City of Raleigh
3b. Deed Book and Page No. Public ROW maintained by the City of Raleigh
3c. Responsible Party (for LLC if R. Blair Hinkle, PE
applicable):
3d. Street address: 127 W. Hargett Street, Suite 800 (P.O. Box 590)
3e. City, state, zip: Raleigh, NC 27602-0590
3f. Telephone no.: 919-996-4011
3g. Fax no.: 919-996-7633
3h. Email address: Blair.Hinkle@raleighnc.gov
Page 1 of 10
PCN Form — Version 1.4 January 2009
4. Applicant Information (if different from owner)
4a. Applicant is: ❑ Agent ❑X Other, specify: C�ty of F�leigh
4b. Name: Gilles Bellot, PE
4c. Business name City of Raleigh
(if applicable):
4d. Street address: 222 West Hargett Street
4e. City, state, zip: Raleigh, NC 27601
4f. Telephone no.: 919-996-4001
4g. Fax no.: 919-996-7633
4h. Email address: gilles.bellot@raleighnc.gov
5. Agent/Consultant Information (if applicable)
5a. Name: L. Mark Pearson, PE
5b. Business name Dewberry Engineers, Inc.
(if applicable):
5c. Street address: 2610 Wycliff St, Suite 410
5d. City, state, zip: Raleigh, NC 27607
5e. Telephone no.: (919) 424-3774
5f. Fax no.: (919) 881-9923
5g. Email address: mpearson@dewberry.com
Page 2 of 10
B. Project Information and Prior Project History
1. Property Identification
1a. Property identification no. (tax PIN or parcel ID):
1 b. Site coordinates (in decimal degrees): Latitude: 35.761945 Longitude: -78.703611
1 c. Property size: 0.9 acres
2. Surface Waters
2a. Name of nearest body of water to proposed project: Walnut Creek
2b. Water Quality Classification of nearest receiving water: C NSW
2c. River basin: Neuse River Basin
3. Project Description
3a. Describe the existing conditions on the site and the general land use in the vicinity of the project at the time of this
application:
Land use in the project vicinity is residential interspersed with forested and maintained utility right-of-ways. The Walnut Creek Greenway crosses the
project south of the bridge and the project is adjacent to City of Raleigh Lake Johnson Park.
3b. List the total estimated acreage of all existing wetlands on the property: 0
3c. List the total estimated linear feet of all existing streams (intermittent and perennial) on the property: 175
3d. Explain the purpose of the proposed project:
See Purpose and Need in the attached cover letter.
3e. Describe the overall project in detail, including the type of equipment to be used:
Standard road building equipment, such as trucks, dozers, and cranes will be used to replace in place, including utility relocations. See cover letter.
4. Jurisdictional Determinations
4a. Have jurisdictional wetland or stream determinations by the � Yes ❑X No ❑ Unknown
Corps or State been requested or obtained for this property /
ro'ect includin all rior hases in the ast? Comments:
4b. If the Corps made the jurisdictional determination, what type � Preliminary ❑ Final
of determination was made?
4c. If yes, who delineated the jurisdictional areas? Agency/Consultant Company:
Name (if known): Other:
4d. If yes, list the dates of the Corps jurisdictional determinations or State determinations and attach documentation.
5. Project History
5a. Have permits or certifications been requested or obtained for �Yes ❑X No ❑ Unknown
this project (including all prior phases) in the past?
5b. If yes, explain in detail according to "help file" instructions.
6. Future Project Plans
6a. Is this a phased project? ❑ Yes ❑X No
6b. If yes, explain.
Page 3 of 10
PCN Form — Version 1.4 January 2009
C. Proposed Impacts Inventory
1. Impacts Summary
1 a. Which sections were completed below for your project (check all that apply):
❑ Wetlands Strea X� — tributaries Buffers Open 1�ters PQd Construction ❑
2. Wetland Impacts
If there are wetland impacts proposed on the site, then complete this question for each wetland area impacted.
2a. 2b. 2c. 2d. 2e. 2f.
Wetland impact Type of impact Type of wetland Forested Type of jurisdiction Area of
number Corps (404,10) or impact
Permanent (P) or DWQ (401, other) (acres)
Tem ora T
W 1 - Choose one Choose one Yes/No -
W2 - Choose one Choose one Yes/No -
W$ - Choose one Choose one Yes/No -
W4 - Choose one Choose one Yes/No -
W5 - Choose one Choose one Yes/No -
Wg - Choose one Choose one Yes/No -
2g. Total Wetland Impacts:
2h. Comments:
3. Stream Impacts
If there are perennial or intermittent stream impacts (including temporary impacts) proposed on the site, then complete this
question for all stream sites impacted.
3a. 3b. 3c. 3d. 3e. 3f. 3g.
Stream impact Type of impact Stream name Perennial (PER) or Type of Average Impact
number intermittent (INT)? jurisdiction stream length
Permanent (P) or width (linear
Temporary (T) (feet) feet)
S1 T Dewatering (Other) Walnut Creek PER Corps 28 107
$2 - Choose one - -
S3 - Choose one - -
S4 - Choose one - -
S5 - Choose one - -
S6 - Choose one - -
3h. Total stream and tributary impacts 10�
3i. Camments:
Bedding and backfill impacts are included within the temporary dewatering area.
Page 4 of 10
PCN Form — Version 1.4 January 2009
4. Open Water Impacts
If there are proposed impacts to lakes, ponds, estuaries, tributaries, sounds, the Atlantic Ocean, or any other open water of
the U.S. then individuall list all o en water im acts below.
4a. 4b. 4c. 4d. 4e.
Open water Name of waterbody
impact number (if applicable) Type of impact Waterbody Area of impact (acres)
Permanent (P) or type
Tem ora T
01 - Choose one Choose
O2 - Choose one Choose
03 - Choose one Choose
04 - Choose one Choose
4f. Total open water impacts
4g. Comments:
5. Pond or Lake Construction
If ond or lake construction ro osed, then com lete the chart below.
5a. 5b. 5c. 5d. 5e.
Pond ID number Proposed use or Wetland Impacts (acres) Stream Impacts (feet) Upland
purpose of pond (acres)
Flooded Filled Excavated Flooded Filled Excavated
P1 Choose one
P2 Choose one
5f. Total:
5g. Comments:
5h. Is a dam high hazard permit required? ❑ Yes ❑ No If yes, permit ID no:
5i. Expected pond surface area (acres):
5j. Size of pond watershed (acres):
5k. Method of construction:
6. Buffer Impacts (for DWQ)
If project will impact a protected riparian buffer, then complete the chart below. If yes, then individually list all buffer impacts
below. If an im acts re uire miti ation, then ou MUST fill out Section D of this form.
6a. Project is in which protected basin? ❑X Neuse � Tar-Pamlico �tawba �ndleman Oth�
6b. 6c. 6d. 6e. 6f. 6g.
Buffer Impact Reason for impact Stream name Buffer Zone 1 Zone 2
number — mitigation impact impact
Permanent (P) or required? (square (square
Tem ora T feet feet
B� P Fill slope for Greenway Walnut Creek No 1,066 1,328
g2 T Utility - Gas & water Walnut Creek No 805 349
63 T Utility - SS Walnut Creek No 1,529 2,219
B4 - Yes/No
B5 - Yes/No
gg - Yes/No
6h. Total Buffer Impacts: 3,aoo 3,s96
6i. Comments:
Page 5 of 10
D. Impact Justification and Mitigation
1. Avoidance and Minimization
1a. Specifically describe measures taken to avoid or minimize the proposed impacts in designing project.
The bridge will be replaced in place on existing elevation with a cored slab bridge. A silt fence will be used during bridge pile removal. A turbidity
curtain will be used during new bent installation and a silt bag with pump will be in place during the pump-around phase.
There will be no deck drains over Walnut Creek.
Traffic is being detoured offsite. Two energy dissipator pads will be installed. See attached cover letter for additional information.
1 b. Specifically describe measures taken to avoid or minimize the proposed impacts through construction techniques.
Top down construction will be utilized, avoiding the need for a temp construction bridge and work pads
A bubble curtain will be employed during construction.
The existing bridge will be demolished without any fill entering Walnut Creek.
2. Compensato Miti ation for Impacts to Waters of the U.S. or Waters of the State
2a. Does the project require Compensatory Mitigation for � Yes ❑X No
impacts to Waters of the U.S. or Waters of the State?
2b. If yes, mitigation is required by (check all that apply): ❑ DWQ ❑ Corps
❑ Mitigation bank
2c. If yes, which mitigation option will be used for this
project? ❑ Payment to in-lieu fee program
❑ Permittee Responsible Mitigation
3. Complete if Usin a Miti ation Bank
3a. Name of Mitigation Bank:
Type: Choose one Quantity:
3b. Credits Purchased (attach receipt and letter) Type: Choose one Quantity:
Type: Choose one Quantity:
3c. Comments:
4. Com lete if Makin a Pa ment to In-lieu Fee Pro ram
4a. Approval letter from in-lieu fee program is attached. ❑ Yes
4b. Stream mitigation requested: linear feet
4c. If using stream mitigation, stream temperature: Choose one
4d. Buffer mitigation requested (DWQ only): square feet
4e. Riparian wetland mitigation requested: acres
4f. Non-riparian wetland mitigation requested: acres
4g. Coastal (tidal) wetland mitigation requested: acres
4h. Comments:
5. Complete if Using a Permittee Responsible Mitigation Plan
5a. If using a permittee responsible mitigation plan, provide a description of the proposed mitigation plan.
Page 6 of 10
PCN Form — Version 1.4 January 2009
6. Buffer Mitigation (State Regulated Riparian Buffer Rules) — required by DWQ
6a. Will the project result in an impact within a protected riparian buffer that requires � Yes ❑X No
buffer mitigation?
6b. If yes, then identify the square feet of impact to each zone of the riparian buffer that requires mitigation. Calculate the
amount of mitigation required.
6c. 6d. 6e.
Zone Reason for impact Total impact Multiplier Required mitigation
(square feet) (square feet)
Zone 1 3(2 for Catawba)
Zone 2 1.5
6f. Total buffer mitigation required:
6g. If buffer mitigation is required, discuss what type of mitigation is proposed (e.g., payment to private mitigation bank,
permittee responsible riparian buffer restoration, payment into an approved in-lieu fee fund).
6h. Comments:
Page 7 of 10
E. Stormwater Management and Diffuse Flow Plan (required by DWQ)
1. Diffuse Flow Plan
1 a. Does the project include or is it adjacent to protected riparian buffers identified 0 Yes ❑ No
within one of the NC Ri arian Buffer Protection Rules?
1 b. If yes, then is a diffuse flow plan included? If no, explain why.
❑X Yes � No
2. Stormwater Mana ement Plan
2a. What is the overall percent imperviousness of this project? 45 %
2b. Does this ro'ect re uire a Stormwater Mana ement Plan? ❑X Yes ❑ No
2c. If this project DOES NOT require a Stormwater Management Plan, explain why:
2d. If this project DOES require a Stormwater Management Plan, then provide a brief, narrative description of the plan:
See attached Stormwater Management Plan
2e. Who will be responsible for the review of the Stormwater Management Plan? �wR
3. Certified Local Government Stormwater Review
3a. In which local overnmenYs 'urisdiction is this ro'ect? N/A
❑ Phase II
3b. Which of the following locally-implemented stormwater management programs ❑ NSW
apply (check all that apply): ❑ USMP
� Water Supply Watershed
� Other:
3c. Has the approved Stormwater Management Plan with proof of approval been ❑Yes ❑ No
attached?
4. DWQ Stormwater Pro ram Review
�Coastal counties
❑ HQW
4a. Which of the following state-implemented stormwater management programs apply �ORW
(check all that apply):
❑ Session Law 2006-246
❑ Other:
4b. Has the approved Stormwater Management Plan with proof of approval been � Yes ❑ No
attached?
5. DWQ 401 Unit Stormwater Review
5a. Does the Stormwater Management Plan meet the appropriate requirements? � Yes ❑ No
5b. Have all of the 401 Unit submittal requirements been met? 0 Yes � No
Page 8 of 10
PCN Form — Version 1.4 January 2009
F. Supplementary Information
1. Environmental Documentation (DWQ Requirement)
1 a. Does the project involve an expenditure of public (federal/state/local) funds or the 0 Yes ❑ No
use of public (federal/state) land?
1 b. If you answered "yes" to the above, does the project require preparation of an
environmental document pursuant to the requirements of the National or State 0 Yes ❑ No
(North Carolina) Environmental Policy Act (NEPA/SEPA)?
1 c. If you answered "yes" to the above, has the document review been finalized by the
State Clearing House? (If so, attach a copy of the NEPA or SEPA final approval
letter.) ❑ Yes 0 No
Commellts: Programmatic Categorical Exclusion is pending FHWA approval
2. Violations (DWQ Requirement)
2a. Is the site in violation of DWQ Wetland Rules (15A NCAC 2H .0500), Isolated
Wetland Rules (15A NCAC 2H .1300), DWQ SurFace Water or Wetland Standards, ❑Yes ❑X No
or Riparian Buffer Rules (15A NCAC 2B .0200)?
2b. Is this an after-the-fact permit application? ❑Yes ❑X No
2c. If you answered "yes" to one or both of the above questions, provide an explanation of the violation(s):
3. Cumulative Impacts (DWQ Requirement)
3a. Will this project (based on past and reasonably anticipated future impacts) result in �Yes ❑X No
additional development, which could impact nearby downstream water quality?
3b. If you answered "yes" to the above, submit a qualitative or quantitative cumulative impact analysis in accordance with the
most recent DWQ policy. If you answered "no," provide a short narrative description.
4. Sewage Disposal (DWQ Requirement)
4a. Clearly detail the ultimate treatment methods and disposition (non-discharge or discharge) of wastewater generated from
the proposed project, or available capacity of the subject facility.
N/A
Page 9 of 10
PCN Form — Version 1.4 January 2009
5. Endangered Species and Designated Critical Habitat (Corps Requirement)
5a. Will this project occur in or near an area with federally protected species or � Yes ❑ No
habitat?
5b. Have you checked with the USFWS concerning Endangered Species Act � Yes ❑ No
impacts?
5c. If yes, indicate the USFWS Field Office you have contacted. Raleigh
5d. What data sources did you use to determine whether your site would impact Endangered Species or Designated Critical
Habitat?
Please refer to Progr. BO for Transport. Projects for Indiana and N. Long-eared bats signed May 20, 2016 by USFWS (add'I copies avail upon request)
Direct surveys for dwarf wedge mussel and Michaux sumac were conducted. (see attached NRTR and PCE)
6. Essential Fish Habitat (Corps Requirement)
6a. Will this project occur in or near an area designated as essential fish habitat? ❑ Yes ❑X No
6b. What data sources did you use to determine whether your site would impact Essential Fish Habitat?
7. Historic or Prehistoric Cultural Resources (Corps Requirement)
7a. Will this project occur in or near an area that the state, federal or tribal
governments have designated as having historic or cultural preservation � Yes ❑X No
status (e.g., National Historic Trust designation or properties significant in
North Carolina history and archaeology)?
7b. What data sources did you use to determine whether your site would impact historic or archeological resources?
NC State Historic Preservation Office (reference letter dated xxxxx)
8. Flood Zone Designation (Corps Requirement)
8a. Will this project occur in a FEMA-designated 100-year floodplain? ❑X Yes ❑ No
8b. If yes, explain how project meets FEMA requirements:
Project located in Special Flood Hazard Zone, Detailed Study with Floodway. Floodplain hydraulic analysis prepared for the project and approved by
the NC Floodplain Mapping Program. Proposed bridge opening is larger and at higher elevation than existing bridge resulting in a decrease in the
100--year water surtace elevation.
8c. What source(s) did you use to make the floodplain determination?
Wake County Flood Insurance Study, National Flood Insurance Program(NFIP) Map 0783
Digi�ally signed by L Ma�k Peareon
Mark Pearson, PE L. Mark Pearson DN:cn=L MarkPeerson,ou=SoutM1eestRegion,
°=��e�E^g'^�'^°., 3/02/2017
mail=mpearson(�tlawberry.com, FUS
Date: 201'l.03.02 09:42:55 -05'00'
Applicant/AgenYs Printed Name ApplicanUAgent's Signature Date
(AgenYs signature is valid only if an authorization
letter from the a licant is rovided.
Page 10 of 10