HomeMy WebLinkAbout20080950 Ver 1_Triage Comments_20080718 Use this form instead of writing inside the folder e Comment Sheet 6A OYK -L$ Triaged By: Reviewer 1 .? Reviewer 2 1? Reviewer 3 Date: 7 Date: > 2 - o ?? Date: 2 Issue Project (Reviewer 1) 9 Issue Project (Reviewer 2) ? Issue with conditions (Reviewer 1) ? Issue with conditions (Reviewer 2) ? More Information (Reviewer 1) ? Return Application (Reviewer 1) ? Send to Regions (Reviewer 1) E] Send to Regions (Reviewer 2) ? More Information (Reviewer 2) ? Return Application (Reviewer 2) SATriage Forms\Triage Issue Sheet.doc PLEASE PRINT `--",LEARLY 08-0950 TT&E Metal & Iron AML Comments July 18, 2008 RETURN. The application package failed to include Required Items 1 and 2 from the level spreader supplement form. From the information provided, it is difficult to determine the location of the level spreader on the site. Also, the stormwater drainage system for the project is not shown, and therefore the DWQ cannot determine if the roadway drainage is being directed to the wet detention ponds or if it is being discharged through the riparian buffer (which would require the use of a level spreader). 2. The proposed wet detention ponds must be designed to meet state requirements regardless of whether the stormwater review is being conducted by the Town or Garner or the DWQ. Please insure that the proposed BMPs include provisions for pretreatment, SA to DA ratios, vegetated shelves and other required design elements listed in the DWQ BMP Manual. Please show the locations of the inlet structures for these wet detention ponds on the plan sheets.