08-0950 TT&E Metal & Iron
AML Comments
July 18, 2008
RETURN.
The application package failed to include Required Items 1 and 2 from the level
spreader supplement form. From the information provided, it is difficult to
determine the location of the level spreader on the site. Also, the stormwater
drainage system for the project is not shown, and therefore the DWQ cannot
determine if the roadway drainage is being directed to the wet detention ponds or
if it is being discharged through the riparian buffer (which would require the use
of a level spreader).
2. The proposed wet detention ponds must be designed to meet state requirements
regardless of whether the stormwater review is being conducted by the Town or
Garner or the DWQ. Please insure that the proposed BMPs include provisions for
pretreatment, SA to DA ratios, vegetated shelves and other required design
elements listed in the DWQ BMP Manual. Please show the locations of the inlet
structures for these wet detention ponds on the plan sheets.