Loading...
HomeMy WebLinkAboutNC0082970_Instream Monitoring for Turbidity_20170222f f rl IL a f " Wafer Resources E NVIRONMEN1 AL. OUAL.ITY February 16, 2017 Mr. T. Pratt Summers, Vice President, Operations CTI of North Carolina, Inc. P.O. Box 576 Savannah, GA 31402 Dear Mr. Summers: ROY COOPER Governor MICHAEL S. REGAN Secrelaq S. JAY ZIMMERMAN Director Subject: Instream Monitoring for Turbidity NPDES Permit NCO082970 CTI of North Carolina, Inc. Wilmington Terminal 1002 S. Front St, Wilmington, NC 28401 New Hanover County Bulk -storage facilities have potential to discharge turbid effluents. Considering that North Carolina has established standards for Turbidity relevant to your facilities receiving -stream classification. Monitoring and permit limits are deemed appropriate to evaluate effluent compliance for saltwater [NCAC 02B. 0211(19)]. For the latest permit renewal, Footnote 4 was added to the effluent pages [Part I, A. (1.) & A (2.)] for Outfalls 001 & 003 at follows: Turbidity — Effluent turbidity shall not cause receiving -stream turbidity to exceed 25 NTU. If background turbidity naturally exceeds 25 NTU, the effluent shall not cause background turbidity to increase. Any discharge exceeding this permit limit will require sufficient instream sampling (upstream and/or downstream) to verify compliance (effluent vs. background). [NCAC 02B. 0220(19)] For January monitoring, the Wilmington Regional Office was contacted regarding Turbidity results for Outfalls 001 & 003 that were greater than 25 NTU. Pursuant to Footnote 4, instream sampling will be required to verify compliance. Please note that Instream monitoring should be conducted at the same frequency as the effluent monitoring. The Division will update our database to add instream monitoring with the following locations designated as Outfalls for the purpose of reporting in eDMR: Outfall 004 — a location no less than 50 -ft upstream of Outfall 003 Outfall 005 — a midpoint between Outfalls 001 & 003 located no less than 50 -ft downstream of Outfall 003 and no less than 50 -ft upstream of Outfall 001 Outfall 006 — a location no less than 50 -ft downstream of Outfall 001. .'-'N otYlinel l'::omlaares -. . State of North Carolina I Environmental Quality 1617 Mail Service Center I Raleigh, North Carolina 27699-1617 919-707-9000 Mr. Summers February 16, 2017 Page 2 of 2 Once you and your staff have identified instream locations within these guidelines, please provide us the coordinates for the permit file. If you have questions, or if we can be of further service, please contact Derek Denard at [derek.denard@ncdenr.gov] or call (919) 807-6307. Respectfully, Derek Denard, Environmental Specialist Compliance & Expedited Permitting Unit Division of Water Resources, NCDEQ Enclosure: NPDES Permit NCO082970 he: Central Files NPDES Program Files WiRO Files/ Attn: Jim Gregson ec: Tom Dolan, CTI of North Carolina, Inc. [TDOLAN@COLONIALGROUPINC.COM] Jim Gregson Uim.gregson@ncdenr.gov] Dean Hunkele [dean.huckele@ncdenr.gov] Anndell Ottaway [AOttaway@colonialterminals.com]