Loading...
HomeMy WebLinkAboutNC0078271_Renewal (Application)_20170110 ANEW 1•1•16 Bets - :e � enn - 4-H Educational Center 804 Cedar Lane•• Reidsville,N.C. 27320• (336) 349-9445• FAX (336) 634-0110 • Wren Thedford NC DENR / DWR /NPDES Unit 1617 Mail Service Center Raleigh,NC 27699-1617 RECEIVEDINCDEQIDWR RE: Permit # NC0078271 JAN 1 0 2017 ,Water Quality • 01-04-17 • Permitting section To Whom It May Concern: We are requesting renewal of the permit There have been no changes since our last renewal. , Please find enclosed Application Form D.. Thank You'', . effery Jo nson Facilities Maintenance Supervisor _ Betsy-Jeff Penn 4-.H Educational.Center - .` 804 Cedar Lane Reidsville, NC 27320 Cooperative Extension Service,North Carolina State University,College of Agriculture and Life Sciences NPDES APPLICATION - FORM D For privately-owned treatment systems treating 100%domestic wastewaters<1.0 MGD Mail the complete application to: N. C.DENR/Division of Water Quality 1 NPDES Unit 1617 Mail Service Center,Raleigh, NC 27699-1617 NPDES Permit NCOO If you are completing this form in computer use the TAB key or the up—down arrows to move from one field to the next. To check the boxes, click your mouse on top of the box. Otherwise,please print or type. 1. Contact Information: Owner Name North Carolina State University Facility Name Betsy-Jeff Penn 4-H Center Mailing Address 804 Cedar Lane City Reidsville State/Zip Code NC/27320 Telephone Number ( 336 349-9445 Fax Number ( 336 ) 634-0110 e-mail Address jeffjohnson@ncsu.edu 2. Location of facility producing discharge: Check here if same address as above Q Street Address or State Road City State/Zip Code County 3. Operator Information: Name of the firm, public organization or other entity that operates the facility. (Note that this is not referring to the Operator in Responsible Charge or ORC) Name Betsy-Jeff Penn 4-H Educational Center Mailing Address 804 Cedar Lane City Reidsville State/Zip Code NC/27320 Telephone Number (336 ) 349-9445 Fax Number (336 ) 634-0110 e-mail Address jeffjohnson@ncsu.edu 1 of3 Form-D 11/12 NPDES APPLICATION -FORM D For privately-owned treatment systems treating 100%domestic wastewaters<1.0 MGD 4. Description of wastewater: Facility Generating Wastewater(check all that apply): Industrial ❑ Number of Employees Commercial El Number of Employees Residential El Number of Homes School ❑ Number of Students/Staff Other ® Explain: Camp/Staff 19 Describe the source(s)of wastewater(example: subdivision, mobile home park, shopping centers, restaurants, etc.): 8 Cabins that sleep 26 each,staff house that sleeps 9,Directors house that sleeps 4,the kitchen and main bath he Number of persons served: 175 average 5. Type of collection system LX Separate(sanitary sewer only) ❑Combined (storm sewer and sanitary sewer) 6. Outfall Information: Number of separate discharge points 1 Outfall Identification number(s) 001 Is the outfall equipped with a diffuser? ❑ Yes 113N° 7. Name of receiving stream(s) (NEW applicants:Provide a map showing the exact location of each outfall): Carroll Creek 8. Frequency of Discharge: ❑ Continuous 171 Intermittent If intermittent: Days per week discharge occurs: 7 Duration: Based on float controlled pump 9. Describe the treatment system List all installed components, including capacities,provide design removal for BOD, TSS, nitrogen and phosphorus. If the space provided is not sufficient, attach the description of the treatment system in a separate sheet of paper. See Attached 2 of 3 Form-D 11/12 NPDES APPLICATION - FORM D For privately-owned treatment systems treating 100%domestic wastewaters<1.0 MGD 10. Flow Information: Treatment Plant Design flow 0.0131MGD Annual Average daily flow .0024 MOD (for the previous 3 years) Maximum daily flow .0078 MOD(for the previous 3 years) 11. Is this facility located on Indian country? ❑ Yes ® No 12. Effluent Data NEW APPLICANTS:Provide data for the parameters listed.Fecal Coliform, Temperature and pH shall be grab samples,for all other parameters 24-hour composite sampling shall be used.If more than one analysis is reported,report daily maximum and monthly average. If only one analysis is reported,report as daily maximum. RENEWAL APPLICANTS: Provide the highest single reading(Daily Maximum)and Monthly Average over the past 36 months for parameters currently in your permit. Mark otherparameters"N/A". Parameter Daily Monthly Units of Maximum Average Measurement Biochemical Oxygen Demand (BODS) 7.7 1.8 Mg/L Fecal Coliform 5.2 1 100mI Total Suspended Solids 6.7 2.4 Mg/L Temperature(Summer) 32 25 Celsius Temperature(Winter) 20 13.1 Celsius pH 8.1 6.5 Stsnderd units 13. List all permits,construction approvals and/or applications: Type Permit Number Type Permit Number Hazardous Waste(RCRA) NESHAPS(CAA) UIC(SDWA) Ocean Dumping(MPRSA) NPDES NC0078271 Dredge or fill(Section 404 or CWA) PSD(CAA) Other Non-attainment program(CAA) 14. APPLICANT CERTIFICATION I certify that I am familiar with the information contained in the application and that to the best of my knowledge and belief such information is true,complete,and accurate. Jeffery Johnson Facilities Maintenance Supervisior Printed name of Person Si•ning Title - January 4 2017 Si I t. .f :. i Date N� h Carolina Gene- tatute 143-215.6(b)(2)states: Any person who knowingly makes any false statement representation, or certification in any application,record,report,plan,or other document files or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article,or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article,shall be guilty of a misdemeanor punishable by a fine not to exceed$25,000,or by imprisonment not to exceed six months,or by both. (18 U.S.C.Section 1001 provides a punishment by a fine of not more than$25,000 or imprisonment not more than 5 years,or both,for a similar offense.) 3 of 3 Form-D 11/12 System Description Betsy Jeff Penn 4-H Educational Center NPDES PERMIT No. NC 0078271 The influent enters the plant at a 13,000 gallon septic tank were most of the solids settle out. From there it passes through a baffle wall into a filter chamber,there are two Polylok PL-525 effluent filters in the chamber. From there it flows into the first of two 8100 gallon septic/recirculation tanks. Each tank has a pair of Polylok PL-525 effluent filters. After exiting the second 8100 gallon Septic/recirculation tank it flows into a 8100 gallon filter dosing pump tank. Up to this point every thing has been gravity feed. The dossing pump tank has 3 sets of submersible duplex turbine pumps rated @ 52 gallons per minute. Each set of pumps operates a zone of E-Z treat Pods, and each set is controlled by a float level switches and a timer that controls the dossing time for each E-Z treat pod:The pumps in each set alternate after each cycle of 4 minutes on 2 minutes off.There is a low limit float that shuts off the pumps in case of low level conditions, and high level float that sets off the alarm and flashing lights at the control panel. The E-Z treat pods are 7feet 9inch square and 34 in deep,they contain a lightweight, non- biodegradable synthetic sphere in three different diameters encapsulated in a mattress 7%feet square by 2 feet thick. Each pod has a spray manifold system containing 12-.0625 diameter brass nozzles that maintains a consistent misting spray.The effluent flows through the mattress coming in contact with the media as it exits the mattress. It flows through 7 large 4 inch under drains, and then flows to the recirculation tank to start the cycle over again. There are three zones of pods. Zone one and two have eight, E-Z treat treatment pods, and zone three has four E-Z treat treatment pods. 2/3 of the influent from each zone is returned to the first septic/recirculation tank were it returns through the system again.The other 3rd is sent back to the pump tank through a cross over ball float valve at which time it returns to the pump tank for recirculation through the system.When the effluent level in the pump tank reaches an elevation of 671.07'the ball valve closes and the effluent is sent to the discharge tank. The control panel contains three set of Ohio Electric electronic panels.This is a 120/240 volt 200 amp system with a heavy duty transfer switch for back up generation.There is a 15000 watt Guardian Ultra Source generator on site for emergency stand by.This is all protected by a weather proof shelter. The discharge tank is a1350 gallon tank with one 60 gallon per minute pump controlled by a float switch and timer. This tank also has a high level float that if activated will set off a alarm and flashing light at the control panel.The flow meter for the system is in this tank. It is a 2" brass ABB T3000 cold water turbine meter numerical display. Once the float is activated in the discharge tank the effluent goes through a SIM/TECH STF- 104/600 micron poly-knit filter sock,from here it enters the Trojan UV2000 ultraviolet disinfection system.The discharge from the UV system goes into a 2'X2' catch basin and down a 4"schedule 40 PVC pipe to Carroll Creek. The Betsy-Jeff Penn 4-H Educational Center has a NPDES permit that allows treated wastewater from the camp to be discharged into Carroll Creek.The current permit, number NC0078271, allows a maximum discharge of 13100 gallons per day and has the following limits on the quality of the discharge. Item Monthly Average Limits Daily Maximum Limits BOD 30.0 mg/L 45.0 mg/L TSS 30.0 NA NH3 as N 12.0 mg/L 35.0 mg/L Fecal Coliform 200/100 ml 400/100mI PH not less than 6.0 nor greater than 9.0 Design Removal System influent Septic Tank Effluent E-Z Treat Treatment System Permitted Concentration Percent Concentration Percent Concentration Monthly Characteristic (mg/l-) Removal (mg/-) Removal (mg/L) Average(mg/L) BOD5 250 40% 150 80% 30 30 TSS 250 40% 150 80% 30 30 Nitrogen 40 • 5% 38 65% 13.3 N/A Phosphorous 11 10% 9.9 0% 9.9 N/A Sludge Management Plan The Betsy-Jeff Penn 4-H Education Center NPDES Permit # NC0078271 currently contracts with Billingsley Septic Tank Company located in Reidsville NC,to have our tanks pump once a year to remove solids and sludge. This is normally done during the winter months when our system sees the least amount of influent.