Loading...
HomeMy WebLinkAboutNC0039594_NOD2015PC0304_20151218 (4) Permit: NC0039594 Owner-Facility: Maiden WWTP Inspection Date: 12/16x2015 Inspection Type: Compliance Evaluation Grit Removal Yes No NA NE b.Mechanical 0 Is the grit free of excessive organic matter? M ❑ ❑ ❑ Is the grit free of excessive odor? 0 ❑ ❑ ❑ #Is disposal of grit in compliance? 0 ❑ ❑ ❑ Comment: Bar Screens Yes No NA NE Type of bar screen a.Manual ❑ b.Mechanical Are the bars adequately screening debris? ❑ ❑ ❑ Is the screen free of excessive debris? N ❑ ❑ ❑ Is disposal of screening in compliance? 0 ❑ ❑ ❑ Is the unit in good condition? N ❑ ❑ ❑ Comment: Screenings and grit are disposed at the County Landfill by a contracted company (Republic Services). Flow Measurement- Influent Yes No NA NE #Is flow meter used for reporting? 0 ❑ ❑ ❑ Is flow meter calibrated annually? 0 ❑ ❑ ❑ Is the flow meter operational? 0 ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ N ❑ Comment: The flow meter is calibrated annually and was last calibrated on 11/18/15 by Clearwater, Inc. Sequencing Batch Reactors Yes No NA NE Type of operation: Is the reactor effluent free of solids? ❑ ❑ ❑ E Does minimum fill time correspond to the peak hour flow rate of the facility? ❑ ❑ 0 ❑ Is aeration and mixing cycled on and off during fill? 0 ❑ ❑ ❑ The operator understands and can explain the process? 0 ❑ ❑ ❑ Comment. Both SBR units were operational and in service. The SBRs are equipped with surface aeration. Equalization Basins Yes No NA NE Page# 6 Permit: NCO039594 Owner-Facility: Maiden VWdTP Inspection Date: 12/16/2015 Inspection Type: Compliance Evaluation Equalization Basins Yes No NA NE Is the basin aerated? 0 ❑ ❑ ❑ Is the basin free of bypass lines or structures to the natural environment? 0 ❑ ❑ ❑ Is the basin free of excessive grease? E ❑ ❑ ❑ Are all pumps present? ❑ ❑ 0 ❑ Are all pumps operable? ❑ ❑ N ❑ Are float controls operable? ❑ ❑ N ❑ Are audible and visual alarms operable? ❑ ❑ N ❑ #Is basin size/volume adequate? N ❑ ❑ ❑ Comment: The SBR effluents are conveyed to an aerated equalization basin prior to chlorination. Disinfection-Liquid Yes No NA NE Is there adequate reserve supply of disinfectant? M ❑ ❑ ❑ (Sodium Hypochlorite)Is pump feed system operational? 0 ❑ ❑ ❑ Is bulk storage tank containment area adequate?(free of leaks/open drains) 0 ❑ ❑ ❑ Is the level of chlorine residual acceptable? N ❑ ❑ ❑ Is the contact chamber free of growth, or sludge buildup? 0 ❑ ❑ ❑ Is there chlorine residual prior to de-chlorination? 0 ❑ ❑ ❑ Comment: De-chlorination Yes No NA NE Type of system ? Liquid Is the feed ratio proportional to chlorine amount(1 to 1)? ❑ ❑ N ❑ Is storage appropriate for cylinders? ❑ ❑ N ❑ #Is de-chlorination substance stored away from chlorine containers? 0 ❑ ❑ ❑ Are the tablets the proper size and type? ❑ ❑ 0 ❑ Comment. Aqueous sodium bisulfite is used for dechlorination. The facility is equipped with an ORP system to assist the wastewater staff in the operation of the chlorination/dechlorination systems. Are tablet de-chlorinators operational? ❑ ❑ 0 ❑ Number of tubes in use? Comment: Flow Measurement- Effluent Yes No NA NE #Is flow meter used for reporting? ❑ 0 ❑ 0 Page# 7