HomeMy WebLinkAboutNC0039594_NOD2015PC0304_20151218 (3) Permit: NCO039594 Owner-Facility: Maiden'/W P Inspection Date: 1 211 6/201 5 Inspection Type: Compliance Evaluation Record Keeping Yes No NA NE Comment: The records reviewed during the inspection were organized and well maintained. Discharge Monitoring Reports (DMRs)were reviewed for the period November 2014 through October 2015. No effluent limit violations were reported and all monitoring frequencies were correct. The ORC will resubmit an amended September 2015 DMR to correct the effluent zinc value (not converted from mg/L to ug/L) and the influent BOD and TSS values on 9123115 and 9128115. The ORC will also review and resubmit(if applicable) any 2015 DMRs that had reported an incorrectly transcribed effluent zinc value. Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? ❑ ❑ ❑ Are all other parameters(excluding field parameters)performed by a certified lab? ❑ ❑ ❑ #Is the facility using a contract lab? 0 ❑ ❑ ❑ #Is proper temperature set for sample storage(kept at less than or equal to 6.0 degrees M ❑ ❑ ❑ Celsius)? Incubator(Fecal Coliform)set to 44.5 degrees Celsius+/-0.2 degrees? ❑ ❑ M ❑ Incubator(BOD)set to 20.0 degrees Celsius+/- 1.0 degrees? ❑ ❑ M ❑ Comment: On-site field analyses (pH total residual chlorine dissolved oxygen,temperature) are performed under the Town's field laboratory certification#5532. Water Tech Labs(BOD, TSS ammonia fecal coliform,total phosphorus total nitrogen)and R&A Labs(toxicity selected metals priority pollutants) have also been contracted to provide analytical support. The laboratory instrumentation used for field analyses appeared to be properly calibrated and documented. The facility staff must ensure that the calibration times are properly documented in the calibration logs and the annual curve verification on the TRC meter is performed every twelve months. Influent Sampling Yes No NA NE #Is composite sampling flow proportional? ❑ M ❑ Cl Is sample collected above side streams? 0 ❑ ❑ ❑ Is proper volume collected? 0 ❑ ❑ ❑ Is the tubing clean? 0 ❑ ❑ ❑ #Is proper temperature set for sample storage(kept at less than or equal to 6.0 degrees 0 ❑ ❑ ❑ Celsius)? Is sampling performed according to the permit? ❑ ❑ ❑ Page# 4 Permit: NCO039594 Owner-Facility: Maiden WWTP Inspection Date: 12/15/2015 Inspection Type: Compliance Evaluation Influent Sampling Yes No NA NE Comment: The subject permit requires composite BOD and TSS influent sampling. The influent composite sampler was collecting time-based composite samples (one sample per hour) without prior Division approval_ The ORC did not know how long the sampler was collecting time-based composite samples; however, the sampler was reprogrammed to collect flow proportional samples during the inspection. Please be advised that the subject permit requires flow proportional composite samples unless prior approval is obtained from the Division. The CIRC and staff must ensure that periodic aliquot verifications(recommend monthly)on the sampler are performed and documented. Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ❑ ❑ ❑ Is sample collected below all treatment units? ❑ ❑ ❑ Is proper volume collected? N ❑ ❑ ❑ Is the tubing clean? N ❑ ❑ ❑ #Is proper temperature set for sample storage(kept at less than or equal to 6.0 degrees 0 ❑ ❑ ❑ Celsius)? Is the facility sampling performed as required by the permit(frequency, sampling type 0 ❑ ❑ ❑ representative)? Comment: The subject permit requires composite and grab effluent sampling_ The ORC and staff must ensure that periodic aliquot verifications(recommend monthly) on the sampler are performed and documented. Upstream 1 Downstream Sampling Yes No NA NE Is the facility sampling performed as required by the permit(frequency, sampling type, and ❑ ❑ ❑ sampling location)? Comment: Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? N ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable 0 ❑ ❑ ❑ Solids, pH, DO. Sludge Judge, and other that are applicable? Comment: The facility appeared to be properly operated and well maintained. The ORC and staff incorporate a comprehensive process control program with all measurements being_ properly documented and maintained on-site. The wastewater staff are notified of alarm conditions through a telemetry type alarm system. Grit Removal Yes No NA NE Type of grit removal a.Manual ❑ Page# 5