Loading...
HomeMy WebLinkAboutNC0035173_Renewal (Application)_20160816 (2)r WaterResources ENVIRONMENTAL QUALITY PAT MCCRORY Govenwr DONALD R. VAN DER VAART Secretary S. JAY ZIMMERMAN Director August 16, 2016 Mr. Tony R. Sprinkle Wieland Copper Products, LLC. 3990 US 311 Hwy N. Pine Hill, NC 27042 Subject: Permit Renewal Application No. NCO035173 Wieland Copper Products, LLC Stokes County. Dear Mr. Sprinkle: The Water. Quality Permitting Section acknowledges receipt of your permit application and supporting documentation received on August 09, 2016. The primary reviewer for this renewal application is Derek Denard. The primary reviewer will review your application, and he will contact you if additional information is required to complete your permit renewal. Per G.S. 150B-3 your current permit does not expire until permit decision on the application is made. Continuation of the current permit is contingent on timely and sufficient application for renewal of the current permit. Please respond in a timely manner to requests for additional information necessary to complete the permit application. If you have any additional questions concerning renewal of the subject permit, please contact Derek Denard at 919-807-6307 or Derek.Denard@ncdenr.gov.. Sincerely, Vw a %feted Wren Thedford Wastewater Branch _cc:.Central Files.. NPDES Winston-Salem Regional Office State of North Carolina I Environmental Quality I Water Resources 1617 -Mail Service Center I Raleigh, North Carolina 27699-1617 919-807-6300 August 4, 2016 Wren Thedford NCDENR Division of Water Quality NPDES Unit 1617 Mail Service Center Raleigh, N.C. 27699-1617 Subject: NPDES Permit NCO035173 Renewal Application Dear Wren: Wieland Copper Products, LLC 3990 US 311 Hwy N PO Box 160 Pine Hall, NC 27042 Phone: (336) 445-4500 Fax: (336) 427-3211 info@wieland.com www.wielandcopper.com RaCa1VaD,NCaEQIDVqR AUG 0 9 2015 ',Mater Quality peittin 3-060n Enclosed is one signed original and 2 copies requesting the renewal of NPDES Discharge Permit NCO035173 for Wieland Copper Products, LLC.. WCP no longer discharges Non -Contact Cooling Water to Outfall 002. There has been no other changes since the issuance of the last permit. If you have any questions please feel free to call me at (336) 445-4526. �Sinnccerely, Tony R. prmkQle Safety & Environmental Supervisor NPDES PERMIT APPLICATION - SHORT FORM C - Minor Industrial Minor industrial, manufacturing and commercial facilities. Mail the complete application to: N. C. Department of Environment. and Natural Resources Division of Water Quality / NPDES Unit 1617 Mail Service Center, Raleigh, NC 27699-1617 1. Contact Information: Owner Name Facility Name Mailing Address City State / Zip Code Telephone Number Fax Number e-mail Address NPDES Permit Number INCO035173 Please print or type. Wieland Copper Products, LLC Wieland Copper Products, LLC 3990 US 311 Hwy N. Pine Hall NC/27042 336-445-4526 336-427-2918 tsprinkle@wieland.com 2. Location of facility producing discharge: Check here if same as above: Yes Street Address or State Road City State / Zip Code County 3990 US 311 Hwy. N. Pine Hall NC/27042 Stokes 3. Operator Information: Name of the firm, consultant or other entity that operates the facility. (Note that this is not referring to the Operator in Responsible Charge or ORC) Name Research & Analytical Laboratories, Inc. Mailing Address PO Box 473 City Kernersville State / Zip Code NC/27042 Telephone Number 336-996-2841 Fax Number 336-996-0326 4. Ownership Status: Federal ❑ State ❑ Private XX Public ❑ Page 1 of 5 C -MI 10/08 NPDES PERMIT APPLICATION - SHORT FORM C - Minor Industrial Minor industrial, manufacturing and commercial facilities. 5. Standard Industrial Classification (SIC) code(s): 3351 6. Number of employees: 489 7. Describe the treatment system List all installed waste treatment components with capacities, describe the processes that generate wastewaters. If the space provided is not sufficient attach a separate sheet of paper with the system description. Barscreen, Aeriation Basin, Clarifier, Tablet Type Chlorinator, Tablet Type De -Chlorinator, Aerobic Digester, and Discharge of Non -Contact Cooling Water to Outfall 003. 8. Is facility covered under federal effluent limitation guidelines? No: XX Yes ❑ If yes, specify the category? 9. Principal product(s) produced: Couper Tubes Principal raw material(s) consumed: Couper Briefly describe the manufacturing process(es): Scrap Copper comes in on railcars and trucks. The scrap copper is melted into copper logs 9" in diameter and 25 feet long or tubes that are 4" in diameter and 63 feet long. The logs are cut into billets that are 9" in diameter and 26" long. The billets are extruded into copper tubes of various sizes for either water tubes or air conditioning tubes. Page 2 of 5 C -MI 10/08 NPDES PERMIT APPLICATION - SHORT FORM C - Minor Industrial Minor industrial, manufacturing and commercial facilities. 10. Amount of principal product produced or raw material consumed Listspecific amounts consumed and/or units of roduction over the last three e 11. Frequency of discharge: Continuous: XX If intermittent: Days per week discharge occurs: 7 Intermittent ❑ Duration: 24 hours/dav 12. Types of wastewater discharged to surface waters only Discharge Product Produced or Raw Material Consumed AVERAGE IA.I J Product Produced or Raw Material Consumed PEAK per Day 21,465 pounds 356,164 pounds per Month 7,525,672 pounds 10,834,000 pounds per Year 90,308,059 pounds 130,000,000 pounds 11. Frequency of discharge: Continuous: XX If intermittent: Days per week discharge occurs: 7 Intermittent ❑ Duration: 24 hours/dav 12. Types of wastewater discharged to surface waters only Discharge Flow GALLONS PER DAY Sanitary - monthly average 5,000 . Utility water, etc. - monthly average Process water - monthly average 398,934 to Outfall 003 Stormwater - monthly average Other - monthly average Explain: Monthly Average total discharge (all types) 13. Number of separate discharge points: 2 Outfall Identification number(s) 001 8a 003 14. Name of receiving stream(s) (Provide a map showing the exact location of each outfall, including latitude and longitude): Unnamed Tributary to the Dan River. Page 3 of 5 C -MI 10/08 i NPDES PERMIT APPLICATION - SHORT FORM C - Minor Industrial Minor industrial, manufacturing and commercial facilities. 15. Effluent Data [for new or proposed discharges] Outfall- 001 Provide data for the parameters listed. Temperature and pH shall be grab samples, for all other parameters 24-hour composite sampling shall be used. If more than one analysis is reported, report daily maximum and monthly average. If only one analysis is reported, report as daily maximum. NOTE: Permittees requesting renewal should complete the table ONLY for the parameters currentlu monitored. Summarixe the nact 3 vatyrc of afflzuant A.wti. Parameter Daily Maximum Monthly Average Units of Measurement Biochemical Oxygen Demand (BOD5) 33 32 Mg/1 Chemical Oxygen Demand (COD) Total Organic Carbon Total Suspended Solids 64 36 Mg/1 Ammonia as N 1.17 0.19 Mg/1 Temperature (Summer) 29 23 C Temperature (Winter). 20 12 C pH 8.3 7.4 Fecal Coliform (If sanitary waste is present) 680 2 #/100 ml Total Residual Chlorine (if chlorine is used) 44 22 Ug/1 16. List all permits, construction approvals and/or applications (check all that apply and provide permit numbers or check none if not applicable): Type Permit Number Type Permit Number Hazardous Waste (RCRA) UIC (SDWA) NPDES PSD (CAA) Non -attainment program (CAA) NCD982124125 NESHAPS (CAA) Ocean Dumping (MPRSA) NCGO030124 Dredge or fill (Section 404 or CWA) Other 17. List any chemicals that may be discharged (Please list and explain source and potential amounts.) Page 4 of 5 C -MI 10/08 i NPDES PERMIT APPLICATION - SHORT FORM C - Minor Industrial Minor industrial, manufacturing and commercial facilities. 15. Effluent Data [for new or proposed discharges] Outfall- 003 Provide data for the parameters listed. Temperature and pH shall be grab samples, for all other parameters 24-hour composite sampling shall be used. If more than one analysis is reported, report daily maximum and monthly average. If only one analysis is reported, report as daily maximum. NOTE: Permittees requesting renewal should complete the table ONLY for the parameters currentlu manitnred. Si mmeirig.,P the nrfct A vo"rc of off7iiont ant" Parameter Daily Maximum Monthly Average Units of Measurement Biochemical Oxygen Demand (BOD5) Chemical Oxygen Demand (COD) Total Organic Carbon Total Suspended Solids Ammonia as N Temperature (Summer) 34 29 C' Temperature (Winter) 29 21 C pH 8.8 8.4 Fecal Coliform (If sanitary waste is present) Total Residual Chlorine (if chlorine is used) 28 24 Ug/L 16. List all permits, construction approvals and/or applications (check all that apply and provide permit numbers or check none if not applicable). Type Permit Number Type Permit Number Hazardous Waste (RCRA) UIC (SDWA) NPDES . PSD (CAA) Non -attainment program (CAA) NCD982124125 NESHAPS (CAA) NCGO030124 Ocean Dumping (MPRSA) Dredge or fill (Section 404 or CWA) Other 17. List any chemicals that may be discharged (Please list and explain source and potential amounts.) Sodium Hypochlorite 3222 pounds per year Selcide 784 2584 pounds per year Seltect 410 4880 pounds per year Page 4 of 5 C -MI 10/08 NPDES PERMIT APPLICATION - SHORT FORM C - Minor Industrial. Minor industrial, manufacturing, and commercial facilities. 18. Is this facility located on Indian country? (check one) Yes ❑ No : XX 19. Applicant Certification I certify that I am familiar with the information contained in the application and that to the best of my knowledge and belief such information is true, complete, and accurate. Tony R. Sprinkle Safety & Environmental Supervisor Printed name of Person Signing Title Date North Carolina General Statute 143-215.6 (b)(2) provides that: Any person who knowingly makes any false statement representation, or certification in any application, record, report, plan, or other document files or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, shall be guilty of a misdemeanor punishable by a fine not to exceed $25,000, or by imprisonment not to exceed six months, or by both. (18 U.S.C. Section 1001 provides a punishment by a fine of not more than $25,000 or imprisonment not more than 5 years, or both, for a similar offense.) Page 5 of 5 C -MI 10/08 I 1W Sludge Management Plan Wieland Copper Products, LLC Permit No. NCO035173 Every 3 months approx. 2000 gallons of sludge is pumped from the aerobic digester by Carolina Backhoe & Septic Tank and hauled to the Archie Elledge Wastewater Treatment Plant located on the southwest side of Winston-Salem, NC for proper disposal. Tony Sprinkle Safety & Environmental Supervisor