Subject: Compliance Inspection
Schneider Mills WWTP
NODES. Permit No. NCO034860
Alexander County
Dear Mr. Swinnie:
Enclosed is a copy of the Compliance Inspection for the inspection conducted at the subject
facility on November 3, 2016, by ON Tuvia. Darren Webb's cooperation during•the site visit was
much appreciated. Please advise the staff involved with this NPDES Permit by forwarding a copy of
the enclosed report.
The following areas.of concern were observed during the inspection:
1) . At the time of the inspection'the facility was missing Chain of Custodies (COC) for toxicity
sampling.
2) . ORC must include the time and date the sample were relinquished on the COC.
3) ORC Must Record the beginning and end time of composite sampling.
The reportshould be self-explanatory; however, should you have any questions concerning
this report, please do not hesitate to contact Ori Tuvia at (704) 235-2190, or at
ori:tuviadOncderingov:
Sincerely,
Ori Tuvia, Environmental -Engineer
Mooresville Regional Office
Division of Water Resources; DEQ
Cc: NPDES Unit _
MRO Files
Mooresville Reglonal Office _
-- - "I nratinn• AM FAM r pnfAn Avn :Ri 0A Int MmA-WHIP; Wrl MlIr,
United States EnvironmentaTrotection Agency
Form Approved
EP Washington D C.20460
A
OMB No. 2040-0057'
Water Compliance Ins ectlon Re 01t v
Approvalexpires83196
Section:A: National Data 'SY stem Codin I.e.,.PCSI
9( ) ,
Transaction Code NPDES yr/mo/day Inspection Type Inspector ". Fac Type
1 'U 2 15 1 3. I NC0034866 111_ 121 16/11/03 117 181 1 ' 19 1 G I 201
21111111 1111.11111 1.111 III:I I I 1.1111 11.111111111 �6
Inspection Work Days: Facility Self Monitoring Evaluation Rating B1 QA —Reserved------.:-
Reserved---67:r.0
67.11,070 i .� 71 I,.' I 72 N i 731 I. 174 75 80
LJ L�
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
Entry Time/Date
Permit Effective. Date
POTW name and NPDES permit Number)
10:20AM 16/11/03
15/11/01
Schneider Mills WWTP
1170 NC Hwy ] 6 N
Exit Time/Date
Permit Expiration Date
Taylorsville NC 28681
01:10PM 16/11/03
20/07/31
Name(s).of Onsite Representative(s)lritles(s)/Phone and Fax Number(s)
Other Facility Data
///
Darren David Webb/ORC/828-632-8181/
Name, Address of Responsible Offlcial/Title/Phone and Fax Number
Contacted
Chip Swinnie,PO Box 519 Taylorsville NC 286810519/Plant Manager/828-632-8181/
No.
Section C; Areas Evaluated During Inspection (Check only those areas evaluated)
Permit Flow Measurement Operations & Maintenance Records/Reports
Self -Monitoring Program Sludge Handling Disposal �. Facility Site Review Effluent/Receiving Waters
�. Laboratory
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date
Ori A Tuvia MRO WQ//704-663-1699/
-
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
W ,Corey •Basinger MRO M/704-235-2194/ .,
Permit: NCO034860 Owner-Facility: Schneider Mills WVVTP
Inspection Date:.. 11/03/2016 - Inspection Type: Compliance Evaluation
.
Pernilt
Yes No NA NE
(If the present permit expires in 6 months or Less) Has the'permittee submitted a new
❑
❑
`,�'
❑
Is the facility as described in the permit?
,.
❑
❑
❑
#Are there any special conditions for the. "permit?
❑
❑
❑
Is access to the plant site restricted;to the, general; public?
V
❑
❑
❑
Is the inspectorgranted access 46 all areas for inspection?
N''❑
❑
❑
Comment: The subject perhAt expires on 7/31/2020...' =
Record Keebino'
Yes No NA NE•
Are"records'kept and maintained as required by the permit?
Is all required information readily available, complete and current?
❑
1]'❑
Are, till records maintained for 3 years (lab. reg. required 5 years)?
❑
❑
' ❑
0
Are aria lyticaI-results consistent with data reported'on DMRs?`: ' '
❑
'
'❑
❑
is the chain-of-custody complete?
;.❑
❑
❑
Dates', times, and loi ation'of sampling
Name of individual performing the sampling
Results of analysis and calibration
Dates of analysis ..
..
Name of person performing analyses -
Transported COCs
�•
Are DMRs.complete: do they include all permit parameters? :-A
, ❑
:❑
;❑
Has the'facility-submitted its annual compliance report to users and DWQ?
❑ -
❑
0
,-❑
(if the facility, is = or,> 5 MGD permitted flow) Do they operate 24/7 with a certified operator
11
IT
❑ ..
on each shift? .
Is the ORC visitation log available and current?
❑
❑
❑
Is the ORC certified at grade equal to or higher than the facility classification?.
N
❑
❑
„❑ .
Is the backup operator. certified at one .grade less'or.greater-than the facility classification?
N,
.❑
. ;❑
,❑
is a copy of the current NPDES permit available on site?
0
❑
❑
❑ •.
Facility has copy. ofprevlousyear's;Annual Re ort on file for review?
:.
Page#
Permit: N00034860 Owner- Facility: Schneider Mills WWTP
Inspection Date: 11/0312016Inspection Type: Compliance Evaluation
Record Keeping - ___ ._._
Yes No NA -NE
Comment: records reviewed during the inspection were organized and well maintained. -DMRs.
-
,-The
'COCs, Calibration jo6s and' ORC visitation lops were •reviewed for the period January 2016
through June 2016.
_ The following were found during the inspection:
At the time of the inspection the facility did not have COCs for toxicity sampling.
the COC.
ORC must include the time and date the sample were relinquished on
The'ORC must ensure thatthe effluent 62H PHTH results (Outfall 001)are reported on
future DMRs as less then (<0.1) the lowest B2E detection level rather then reporting the
detection level (0.1).
ORC Must Record the beginning and end time of composite sampling.
Laboratory
Yes. No .NA NE
Are field parameters performed by certified personnel or laboratory?-
❑
❑
�_
Are all other parameters(excluding field parameters) performed by a certified lab?
„ A . ❑
❑
❑
# Is.the facility using a contract lab?
❑
❑
❑
# Is .proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
M. ❑
1:1
❑
Celsius)?
Incubator'(Fecal Coliform) set to 44.5 degrees Celsius+/_ 0.2 degrees?
❑ El11
Incubator (BOD) set to 20.0 degrees. Celsius +/-1.0 degrees?
❑ ❑.
❑
Comment: On-site field analyses (dissolved oxygen off temperature total residual chlorine)
are
performed under the Company's field laboratory certification #5012. Water Tect`l_abs
(BOD TSS ammonia nutrients) and R & A Laboratories, Inc. (toxicity and metals) have
also'been contracted to provide analytical support.
Effluent Sampling
Yes No NA NE
Is composite sampling flow proportional?
❑
' ❑
❑
Is sample collected below all treatment units?
`❑
❑
❑
Is propervolume collected?
0 ❑
❑
❑
Is the tubing clean?
❑
❑
❑
# Is proper temperature set for sample storage (kept at less than or equal to, 6.0 degrees
N ❑
❑
0
Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type
representative)?
Comment:'. , Th'e'subiect permit requires both composite and grab effluent samples The Division
_ approved a variance to collect time-based.composite samples on 5/26/1998 provided that.
the flows do not vary by more than 300/6. The sampler was collecting 300 ml. aliquot every
twenty minutes with an internal temperature of less than four degrees celsius.
The facilitv.staff must ensure to perform and document periodic aliquot verifications on the
composite sampler.
Page#
4
Permit: NC0034860: Owner -Facility:. Schneider MillsWWTP;. „
'Inspection'Date: 11/03/2016 `"" Inspection Type:' Compliance Evaluation •.•, - „
Ur)Stream`/ Downstream Samolinp
Yes No NA NE ...'
Is the facility sant,pling performed as required by the permit (frequency, sampling type;' and
=❑
❑ '❑
sampling)ocation)? ..
Comment:
Operations & Maintenance .
Yes No NA: NE
Is the plant generally clean with acceptable housekeeping?
❑
❑ •❑
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable
❑
❑ ❑
Solids, pH, DO, Sludge Judge, and other, that are'applicable?
. Comment: 'The wastewater facility appeared to be oropeirly operated and well maintained The ORC
incorporates a comprehensive process control program with all measurements being
Properly documented and maintained on-site.
Bar Screens
Yes'!- No NA—
NE-Type of bar screen ..
.:
a:Manual `,..
b:Mechanical
(] .
Are the- bars adequately screening debris?
❑:
❑ `0
Is the screen free of excessive debris?
❑ .
Is disposal of screening in compliance?
❑
❑ ' E
Is the unit 16 good condition?
Comment:' Bar -screenings are disposed at the Alexander County Landfill.
Flow Measurement =Influent -
Yes No NA'NE "
# Is flow meter used for reporting?
11
El . ❑
Is flow meter calibrated annually?
❑
❑ ❑
Is the flow rh6teroperational?
>❑ .
'0 -
(If units are separated) Does the chart recordermatch the flow meter?
0 :' ❑ `
❑
Comment: The influent flow meter (Outfall 001) is calibrated twice per year and was last calibrated on
7/24/2016 by ISL
The flows -for Outfall 002 are based on the calculated backwash volume
(3 150 -gallons) and
• the number of backwash events per day_
.
Aeration;Basins
Yes_:No NA =NE. '4.
Mode of operation `
; •' Ext Air
Type. of aeration system
- :Surface
Is the basin free of dead spots?
Page# 5
f
Permit' NC0034660 Owner - Facility:
Schneider Mills WWTP .
Inspection Dater 11/03/2016 Inspection Type:-
Compliance -Evaluation,
Aeration' -Basins
r Yes No NA NE, -
Are surface aerators and mixers operational?,
:.❑ . ❑ ❑ -
Are the diffusers operational?
❑ ' ❑ M j ❑ .,
Is the foam the proper color forthe treatment process?
❑ ❑
Does the foam cover less than 25% of the basin's surface?0
❑ ❑ ❑
Is the DO level acceptable?
N [3❑ ❑
Is the DO level acceptable?(1.0 to 3.0 ng/I)
❑ ❑ :❑
Comment: .Aciueous lime and soda ash are added to maintain appropriate,
DH/alkalinity levels. The. ....
ORC also adds food (BOD)/nutrient (nitrogen and phosphorus) supplements and selective
microrganisms to maintain the biological treatment brocess: . .
-Secondary Clarifier
Yes No NA NE
Is the clarifier free of black and odorous wastewater?
0 : ❑ `❑
Is the site free of excessive buildup of solids in center well of circular clarifier?
❑ : ❑ ❑ .
Are weirs level?
0 ❑ 11 ;❑
Is the site free of weir blockage?
❑ ❑.. ❑ "
Is the,site:free of evidence of short-circuiting?
❑ ❑, .
Is scum removal adequate? _
- ❑ .
Is thesitefree of excessive floating sludge?
�> ,❑ . ❑
Is the drive unit operational?
- 11
Is the return rate acceptable (low turbulence)?
❑ ❑ ❑
Is the overflow clear of excessive solids/pin floc?
E.- ❑ ❑ ❑
Is the ,sludge blanket level acceptable? (Approximately Y4 of the sidewall depth)
E . 0 • -❑ 0
Comment: Polymer is added to the clarifier influent to enhance settling.
•
.
Pumps -RAS -WAS
Yes No :NA .NE
Are pumps in place?
Are pumps operational? .
E ❑ ❑ ❑
Are there adequate spare parts a,nd supplies,.on site?
❑" ❑ ❑
Comment:
;
Effluent Pipe
Yes,No NA -NE
Is.ri ht of wa to:the outfall ro erl „maintained?
9 Y P p y
�_ ❑ ❑ ❑
., .
`❑
Are the receiving, water free`of foam other than trace amounts and other debris?
'❑
If effluent.(dlffuser'pipes,are reqEl
uired) are they operating properly?,
El❑ _ .
.. ,
Page# ': 6
Permit: NCO034860 Owner- Facility.: Schneider Mills WWTP
:Inspection Date: 11/03/2016 Inspection Type: compliance Evaluation
Effluent Pipe
Yes No NA NE
Comment: The effluent appeared to be milky, with no floatable solids or foam The receiving
stream'
changed color due to4he color of the effluent.
Aerobic Digester
Yes No NA NE
Is the capacity adequate?'
0
. ❑
❑
Is the mixing adequate?
0
❑
❑
1
Is the site free of excessive foaming in the tank?
F
# Is the odor acceptable?
1:1
❑
# Is tankage available for properly waste sludge?
13
Comment:
Drying Beds
Yes No NA NE
Is there adequate drying bed space?
Is the sludge distribution on drying beds appropriate?
0rl.
Are the drying beds free of vegetation?
# Is the site free of dry sludge remaining in beds?'
.0 •
.
Is'the site free of stockpiled sludge?
Is the filtrate from sludge drying beds returned to the front of the plant?
N
El
1:1'
# Is the sludge disposed of through county landfill?
0
0
# Is the sludge land applied?
"0
1
(Vacuum filters) Is polymer mixing adequate?
0
Comment: The dewatered sludges from the wastewater treatment system (drying beds) and
water
treatment system are transported to the Alexander County Landfill for disposal
}
Page# .
7