NC0001422_Table 2 SuttonPrediction LimitsMarch2015_20150805
L. V. Sutton Energy Complex March 2015 March 2015 SynTerra MW-07C Barium Parametric 0.058 0.093 N 99 * MW-07C Boron Parametric 0.49 0.046 Y 99 * MW-07C Chloride Parametric-Logtransformed 30 296.000 0.01 .014 N 99 * MW-07C Iron Parametric-Logtransformed 0.05 5.190 0.004 .010 N 99 1/2 PQL MW-07C Manganese Parametric 0.202 0.712 N 99 * MW-07C Nitrate Parametric-Logtransformed 0.76 0.167 0.007 .006 Y 99 * MW-07C Sulfate Parametric 67 48.000 Y 99 * MW-07C Total Dissolved Solids Parametric-Logtransformed 140 450.000 0.012 .014 N 99 * MW-11 Barium Parametric 0.085 0.046 Y 99 * MW-11 Chloride Nonparametric 3.9 295.000 N 91.8 None Required MW-11 Iron Parametric-Logtransformed 0.119 5.190 0.005 .010 N 99 1/2 PQL MW-11 Manganese Parametric 0.033 0.712 N 99 * MW-11 Nitrate Parametric 0.52 0.167 Y 99 * MW-11 Sulfate Parametric 13 48.000 N 99 * MW-11 Total Dissolved Solids Parametric-Logtransformed 12.5 450.000 0.009 .014 N 99 1/2 PQL MW-12 Barium Parametric 0.036 0.093 N 99 * MW-12 Boron Parametric 1.5 0.046 Y 99 * MW-12 Chloride Parametric-Logtransformed 110 296.000 0.012 .014 N 99 * MW-12 Iron Parametric-Logtransformed 0.112 5.190 0.005 .010 N 99 * MW-12 Manganese Parametric 0.316 0.712 N 99 * MW-12 Sulfate Parametric 160 48.000 Y 99 * MW-12 Total Dissolved Solids Parametric 430 450.000 N 99 * MW-19 Arsenic Nonparametric 0.002 0.010 N 91.8 None Required MW-19 Barium Parametric 0.085 0.093 N 99 1/2 PQL MW-19 Boron Parametric 2.27 0.046 Y 99 * MW-19 Chloride Parametric-Logtransformed 28 296.000 N 99 * MW-19 Iron Parametric-Logtransformed 1.38 5.190 0.01 .014 N 99 1/2 PQL MW-19 Manganese Parametric 0.444 0.712 0.007 .010 N 99 * MW-19 Sulfate Parametric 150 48.000 Y 99 * MW-19 Thallium Nonparametric 0.0004 0.010 N 79.5 None Required MW-19 Zinc Parametric-Logtransformed 0.013 0.016 0.003 .003 N 99 1/2 PQL MW-19 Total Dissolved Solids Parametric 400 450.000 N 99 * Logtransformed ResultPrediction Limit TABLE 2. SUMMARY OF INTERWELL PREDICTION LIMIT RESULTS Well Number Comparison Type Logtransformed Prediction Limit Confidence Level (%) Sutton Ash Ponds Detected Parameter March 2015 Result (mg/L) Treatment of Nondetects Failure Y/N P:\Duke Energy Progress.1026\08.SUTTON PLANT\09.2015 Well Sampling\Stats\Table 2 SuttonPrediction LimitsMarch2015 1 of 4 L. V. Sutton Energy Complex March 2015 March 2015 SynTerra Logtransformed ResultPrediction Limit TABLE 2. SUMMARY OF INTERWELL PREDICTION LIMIT RESULTS Well Number Comparison Type Logtransformed Prediction Limit Confidence Level (%) Sutton Ash Ponds Detected Parameter March 2015 Result (mg/L) Treatment of Nondetects Failure Y/N MW-21C Arsenic Parametric 0.055 0.006 Y 99 1/2 PQL MW-21C Barium Parametric 0.066 0.093 N 99 * MW-21C Boron Parametric 2.02 0.0460 Y 99 * MW-21C Chloride Parametric 32 296.000 N 99 * MW-21C Iron Parametric 5.55 5.190 Y 99 * MW-21C Manganese Parametric 0.493 0.712 N 99 * MW-21C Nickel Parametric 0.0090 0.004 Y 99 * MW-21C Sulfate Nonparametric 130.000 74.000 Y 79.5 None Required MW-21C Total Dissolved Solids Parametric 420.000 450.000 N 99 * MW-22B Barium Parametric 0.010 0.093 N 99 * MW-22B Chloride Parametric 2.200 296.000 N 99 * MW-22B Manganese Parametric 0.006 0.712 N 99 1/2 PQL MW-22B Nitrate Parametric 0.380 0.167 Y 99 * MW-22B Sulfate Parametric-Logtransformed 4.40000 48.000 0.008 .010 N 99 * MW-22C Barium Parametric 0.1080 0.093 Y 99 * MW-22C Boron Parametric 2.6900 0.046 Y 99 * MW-22C Chloride Parametric 34.000 296.000 N 99 * MW-22C Iron Parametric 0.499 5.190 N 99 1/2 PQL MW-22C Manganese Parametric 0.986 0.712 Y 99 * MW-22C Nitrate Nonparametric 0.380 0.200 Y 79.5 None Required MW-22C Sulfate Nonparametric 160.000 74.000 Y 79.5 None Required MW-22C Thallium Parametric 0.001 0.003 N 99 1/2 PQL MW-22C Total Dissolved Solids Parametric 430.0000 450.000 N 99 * MW-23B Barium Parametric 0.0390 0.093 N 99 * MW-23B Boron Parametric 0.245 0.046 Y 99 * MW-23B Chloride Parametirc 3.000 296.000 N 99 * MW-23B Iron Parametric-Logtransformed 0.02600 5.190 0.003 .010 N 99 1/2 PQL MW-23B Manganese Parametric 0.0110 0.712 N 99 * MW-23B Nitrate Parametric 0.2500 0.167 Y 99 * MW-23B Selenium Parametric 0.00700 0.010 N 99 1/2 PQL MW-23B Sulfate Parametric 15.0000 48.000 N 99 * MW-23B Total Dissolved Solids Parametric-Logtransformed 55.000 450.000 0.011 .014 N 99 * P:\Duke Energy Progress.1026\08.SUTTON PLANT\09.2015 Well Sampling\Stats\Table 2 SuttonPrediction LimitsMarch2015 2 of 4 L. V. Sutton Energy Complex March 2015 March 2015 SynTerra Logtransformed ResultPrediction Limit TABLE 2. SUMMARY OF INTERWELL PREDICTION LIMIT RESULTS Well Number Comparison Type Logtransformed Prediction Limit Confidence Level (%) Sutton Ash Ponds Detected Parameter March 2015 Result (mg/L) Treatment of Nondetects Failure Y/N MW-23C Barium Parametric 0.0380 0.093 N 99 * MW-23C Boron Parametirc 3.060 0.046 Y 99 * MW-23C Chloride Parametirc 32.000 296.000 N 99 * MW-23C Iron Parametirc 0.1470 5.190 N 99 * MW-23C Manganese Parametirc 0.3840 0.712 N 99 * MW-23C Nitrate Parametirc 0.0400 0.167 N 99 1/2 PQL MW-23C Sulfate Parametirc 120.000 48.000 Y 99 * MW-23C Total Dissolved Solids Parametric 380.000 450.000 N 99 * MW-24B Barium Parametric 0.049 0.093 N 99 * MW-24B Boron Parametric 0.6090 0.046 Y 99 * MW-24B Chloride Parametric 18.0000 296.300 N 99 * MW-24B Iron Nonparametric 0.016 9.700 N 91.8 None Required MW-24B Manganese Parametric 0.0400 0.712 N 99 * MW-24B Nitrate Nonparametric 0.0700 0.200 N 79.5 None Required MW-24B Sulfate Parametric 38.0000 48.000 N 99 * MW-24B Total Dissolved Solids Nonparametric 180.0000 500.000 N 91.8 None Required MW-24C Arsenic Parametric 0.003 0.006 N 99 1/2 PQL MW-24C Barium Parametric 0.043 0.093 N 99 * MW-24C Boron Parametric 1.15 0.046 Y 99 * MW-24C Chloride Parametric 160 296.000 N 99 * MW-24C Iron Parametric 5.6 5.190 Y 99 * MW-24C Manganese Parametric 1.47 0.712 Y 99 * MW-24C Nickel Parametric 0.006 0.004 Y 99 1/2 PQL MW-24C Sulfate Parametric 160 48.000 Y 99 * MW-24C Zinc Parametric 0.068 0.016 Y 99 * MW-24C Total Dissolved Solids Parametric 500 450.000 Y 99 * MW-27B Barium Parametric 0.038 0.093 N 99 * MW-27B Boron Nonparametric 0.241 0.050 Y 79.5 None Required MW-27B Chloride Parametric 19 296.000 N 99 * MW-27B Manganese Parametric 0.078 0.712 N 99 * MW-27B Nitrate Parametric 1.5 0.167 Y 99 * MW-27B Selenium Parametric 0.036 0.010 Y 99 * MW-27B Sulfate Parametric 75 48.000 Y 99 * MW-27B Total Dissolved Solids Parametric 120 450.000 N 99 * P:\Duke Energy Progress.1026\08.SUTTON PLANT\09.2015 Well Sampling\Stats\Table 2 SuttonPrediction LimitsMarch2015 3 of 4 L. V. Sutton Energy Complex March 2015 March 2015 SynTerra Logtransformed ResultPrediction Limit TABLE 2. SUMMARY OF INTERWELL PREDICTION LIMIT RESULTS Well Number Comparison Type Logtransformed Prediction Limit Confidence Level (%) Sutton Ash Ponds Detected Parameter March 2015 Result (mg/L) Treatment of Nondetects Failure Y/N MW-28B Barium Parametric 0.032 0.093 N 99 * MW-28B Chloride Parametric 4.3 296.000 N 99 * MW-28B Manganese Parametric 0.01 0.712 N 99 1/2 PQL MW-28B Nitrate Parametric 0.28 0.167 Y 99 * MW-28B Sulfate Nonparametric 11 74.000 N 79.5 None Required MW-28B Total Dissolved Solids Parametric-Logtransformed 46 450.000 0.011 .014 N 99 * MW-28C Barium Parametirc 0.052 0.093 N 99 * MW-28C Chloride Parametric 2.7 296.000 N 99 * MW-28C Iron Parametric 0.015 5.190 N 99 1/2 PQL MW-28C Manganese Parametric 0.014 0.712 N 99 * MW-28C Nitrate Parametric 0.81 0.167 Y 99 * MW-28C Sulfate Parametric 7.4 48.000 N 99 * MW-28C Total Dissolved Solids Parametric-Logtransformed 33.000 450.000 0.01 .014 N 99 * MW-31C Barium Parametric 0.057 0.093 N 99 * MW-31C Boron Parametric 1.1900 0.4600 Y 99 * MW-31C Chloride Parametric 170 296.000 N 99 * MW-31C Iron Parametric 3.44 5.190 N 99 * MW-31C Manganese Nonparametric 1.840 0.712 Y 79.5 None Required MW-31C Sulfate Parametric 160 48.000 Y 99 * MW-31C Zinc Nonparametric 0.049 0.020 Y 79.5 None Required MW-31C Total Dissolved Solids Parametric 510 450.000 Y 99 * NOTES:Prepared by: JHG Checked by: KF Only constituents detected above the PQL in compliance wells during the March 2015 monitoirng event were analyzed. Prediction limit comparison type is based on the percentage of nondetects and distribution of the dataset (Table 1) PQL Practical quantitation limit *Data set does not contain any nondetects None Required Percentage of nondetects greater than or equal to 50 percent and less than 90 percent or dataset is non-normally distributed Replace with 1/2 PQL Percentage of nondetects less than 50 percent and the data distribution is normal or lognormal or percentage of nondetects is greater than or equal to 90 percent (ND)Prediction limit for nonparametric comparison was the PQL for a nondetect Result exceeds the prediction limit P:\Duke Energy Progress.1026\08.SUTTON PLANT\09.2015 Well Sampling\Stats\Table 2 SuttonPrediction LimitsMarch2015 4 of 4