HomeMy WebLinkAboutNC0000396_Table H-1 Summary of Percent Nondetects, Treatment Type, and Data Distribution_20150823July 2015
Asheville Plant
TABLE H-1. SUMMARY OF PERCENT NONDETECTS, TREATMENT TYPE, AND
DATA DISTRIBUTION
Asheville Steam Electric Plant
Well Number
Detected Parameter
Percent
Nondetected
Treatment of
Nondetects
Distribution
Background Wells
CB -1
Barium
0
*
Non Normal
CB -1
Chloride
36
None Required
Non Normal
CB -1
Iron
0
*
Lognormal
CB -1
Manganese
0
*
Non Normal
CB -1
Nitrate
0
*
Lognormal
CB -1
Sulfate
64
None Required
Not Applicable
CB -1
Zinc
21
Replace with 1/2 PQL
Normal
CB -1
Total Dissolved Solids
86
None Required
Not Applicable
CB -9
Barium
0
*
Normal
CB -9
Chloride
0
*
Normal
CB -9
Iron
0
*
Normal
CB -9
Manganese
0
*
Normal
CB -9
Nitrate
0
*
Normal
CB -9
Sulfate
13
Replace with 1/2 PQL
Lognormal
CB -9
Zinc
0
*
Normal
CB -9
Total Dissolved Solids
25
Replace with 1/2 PQL
Normal
Compliance Wells
CB -2
Barium
0
*
Normal
CB -2
Boron
0
*
Normal
CB -2
Chloride
0
*
Normal
CB -2
Iron
14
Replace with 1/2 PQL
Normal
CB -2
Manganese
0
*
Normal
CB -2
Nitrate
43
Replace with 1/2 PQL
Lognormal
CB -2
Sulfate
0
*
Normal
CB -2
Zinc
0
*
Normal
CB -2
Total Dissolved Solids
0
*
Lognormal
CB -3R
Arsenic
88
None Required
Not Applicable
CB -3R
Barium
0
*
Normal
CB -3R
Boron
0
*
Normal
CB -3R
Chloride
0
*
Normal
CB -3R
Chromium
75
None Required
Not Applicable
CB -3R
Copper
88
None Required
Not Applicable
CB -3R
Iron
0
*
Normal
CB -3R
Manganese
0
*
Normal
CB -3R
Nickel
63
None Required
Not Applicable
CB -3R
Nitrate
13
Replace with 1/2 PQL
Lognormal
CB -3R
Sulfate
0
*
Normal
CB -3R
I Zinc
13
1 Replace with 1/2 PQL
Lognormal
CB -3R
I Total Dissolved Solids
0
1*
Normal
July 2015
SynTerra
P: \ Duke Energy Progress.1026 \ 102. Asheville Ash Basin GW Assessment Plan \ 1.11 CSA Reporting \ FINAL CSA AUG 20
2015 \ APPEN \ APP H \ Table H-1 Summary of Percent Nondetects, Treatment Type, and Data Distribution.xls 1 of 3
July 2015
Asheville Plant
DATA
Asheville Steam Electric Plant
Well Number
Detected Parameter
Percent
Nondetected
Treatment of
Noncletects
Distribution
Compliance Wells cont.
CB -4
Barium
0
*
Normal
CB -4
Boron
0
*
Normal
CB -4
Chloride
0
*
Normal
CB -4
Iron
29
Replace with 1/2 PQL
Lognormal
CB -4
Manganese
0
*
Normal
CB -4
Nitrate
0
*
Normal
CB -4
Selenium
29
Replace with 1/2 PQL
Normal
CB -4
Sulfate
0
*
Normal
CB -4
Total Dissolved Solids
0
*
Normal
CB -4B
Arsenic
57
None Required
Not Applicable
CB -4B
Barium
0
*
Normal
CB -4B
Chloride
0
*
Normal
CB -4B
Iron
0
*
Normal
CB -4B
Manganese
0
*
Normal
CB -4B
Sulfate
0
*
Non Normal
CB -4B
Total Dissolved Solids
0
*
Non Normal
CB -5
Barium
0
*
Normal
CB -5
Boron
0
*
Normal
CB -5
Chloride
0
*
Normal
CB -5
Iron
0
*
Normal
CB -5
Manganese
0
*
Normal
CB -5
Nitrate
57
None Required
Not Applicable
CB -5
Sulfate
0
*
Normal
CB -5
Thallium
93
Replace with 1/2 PQL
Non Normal
CB -5
Total Dissolved Solids
0
*
Normal
CB -6
Barium
0
*
Normal
CB -6
Boron
0
*
Normal
CB -6
Chloride
0
*
Normal
CB -6
Iron
0
*
Normal
CB -6
Manganese
0
*
Normal
CB -6
Sulfate
0
*
Lognormal
CB -6
Total Dissolved Solids
0
*
Normal
CB -7
Barium
0
*
Normal
CB -7
Boron
0
*
Normal
CB -7
Chloride
0
*
Normal
CB -7
Selenium
36
Replace with 1/2 PQL
Normal
CB -7
Sulfate
0
*
Normal
CB -7
Total Dissolved Solids
0
*
Normal
P:\Duke Energy- Progress.1026\102, Asheville. Ash Basin GW Assessment Plan\1.11 CSA Reporting\FINAL CSA AUG 20
2015\APPLN \APP H\Table H-1 Summary of Percent Nondetects, Treatment Type, and Data Distribution.xls 2 of 3
July 2015
Asheville Plant
TABLE H-1. SUMMARY OF PERCENT NONDETECTS, TREATMENT TYPE, AND
DATA DISTRIBUTION
Asheville Steam Electric Plant
Well Number
Detected Parameter
Percent
Nondetected
Treatment of
Nondetects
Distribution
Compliance Wells cont.
CB -8
Barium
0
*
Normal
CB -8
Boron
0
*
Normal
CB -8
Chloride
0
*
Normal
CB -8
Iron
7
Replace with 1/2 PQL
Lognormal
CB -8
Manganese
0
*
Normal
CB -8
Mercury
36
Replace with 1/2 PQL
Normal
CB -8
Nitrate
0
*
Normal
CB -8
Selenium
0
*
Normal
CB -8
Sulfate
0
*
Normal
CB -8
Zinc
21
Replace with 1/2 PQL
Lognormal
CB -8
Total Dissolved Solids
0
*
Normal
GW -1
Barium
0
*
Normal
GW -1
Chloride
50
None Required
Non Normal
GW -1
Iron
0
*
Non Normal
GW -1
Manganese
0
*
Normal
GW -1
Mercury
30
Replace with 1/2 PQL
Normal
GW -1
Nitrate
0
*
Normal
GW -1
Selenium
65
None Required
Not Applicable
GW -1
Sulfate
60
None Required
Not Applicable
GW -1
Zinc
0
*
Non Normal
GW -1
I Total Dissolved Solids
5
Replace with 1/2 PQL
Normal
July 2015
SynTerra
NOTES: Prepared by: MCM Checked by: KLS
Only constituents detected above the PQL in compliance wells during the April 2015 monitoring event were analyzed.
PQL Practical quantitation limit
* Data set does not contain any nondetects
None Required Percentage of nondetects greater than 50 % and less than 90 % or dataset is
non -normally distributed
Replace with 1/2 PQL Percentage of nondetects less than or equal to 50 % and the data distribution is normal or lognormal or
percentage of nondetects is greater than or equal to 90
Not Applicable Data set will be statistically analyzed using nonparametric methods because the % of
nondetects is greater than 50 % and less than 90
P: \ Duke Energy Progress.1026 \ 102. Asheville Ash Basin GW Assessment Plan \ 1.11 CSA Reporting \ FINAL CSA AUG 20
2015 \ APPEN \ APP H \ Table H-1 Summary of Percent Nondetects, Treatment Type, and Data Distribution.xls 3 of 3