April 12, 2016
Mr. Jadd Brewer
WaterQ tS'uali Services,Inc.
P.O. Box 1167 REDENEDINCDE(�D
Banner Elk,NC 28604-1167 APR 13 2016
SUBJECT: Compliance Evaluation Inspection Water Quality
ion
Yonahlossee WWTP Permitting
NPDES Permit#NCO032212
Watauga County
Dear Mr. Brewer:
A Compliance Evaluation Inspection was performed on the facility by George Smith, along with April
Norton on March 23, 2016.Mr. Brandon Hughes, ORC, Grade II; Mr. Jadd Brewer,Back-up ORC, Grade
III; were present for the inspection. The inspection is comprised of an overall evaluation of the facilities
equipment, capability to meet effluent limits, and compliance with the NPDES permit.
Permit
Your NPDES permit became effective February 1, 2013 and expires September 30, 2017.•This office
received a copy of the letter dated February 17, 2016 requesting the facility be changed from composite to
grab sampling. The permitted flow for this facility will need to be changed from 0.04 MGD to 0.03 MGD.
Records &Reports
The operator and plant log are printed on a form showing visitation times and plant conditions.The log will
be examined more thoroughly during the next year inspection for visitation times,observations,and process
control.
The chain of custody forms and calibrations records are in good order. Field test calibrations were
documented for pH,Temperature, and Dissolved Oxygen.
Facility Site Review
The treatment plant is not open to the environment.The building has fallen down.The plant can be visually
operated and maintained in a safe manner.
The left-side of the treatment unit is not operated.
The equalization basin is located in a separate building.The pumps are working. This treatment unit is still
located in a building with poor lighting.
The aeration basin diffusers are working. The blower motors were operational.
A 1-inch manual barscreen is manually cleaned. It protects the plant.
State of North Carolina I Environmental Quality I Water Resources
450 West Hanes Mill Road,Swte 300,Winston-Salem,NC 27105
Phone 336-776-9800\Internet:www.ncdenr gov
The 10-foot circular clarifier had no solids coming over the weirs. The blanket height in the 10-foot deep
clarifier is not generally measured. Settleability is used to judge process control conditions.
The Trojan 200 UV disinfection unit is working. The indicator lights are on.
Flow Measurement
The recording flow measuring device was calibrated by B.W.Allen on October 8,2015.
Laboratory
Water Quality Lab, Inc. 4544 is certified, and performed the following field tests: Dissolved Oxygen, pH,
and Temperature.
The pH meter is calibrated with a two-point buffer of 4& 10, and check with a pH 7 buffer.
A calibration log was kept for pH and dissolved oxygen, and total residual chlorine. Temperature is
traceable to NIST.
Effluent/Receiving Waters
The effluent, which discharges to Lance Creek, Class C; Trout waters, was clear, no color, no solids, no
odor.The stream does not appear to be impacted.
Operations &Maintenance
The Class II facility was maintained by the following contingent:Mr.Brandon Hughes,ORC, Grade II and
Mr. Jadd Brewer,Back-up ORC, Grade III.
Self-Monitoring Program
A time composite sample is performed at 100 mL/hr. The NPDES flow proportional requirement will not
be examined at this time. The NPDES Unit is reviewing the request to change the permit from flow
proportional sample to grab sample.
A review of the monthly self-monitoring reports from August 2015 through January 2016 did not show
any limit violations.
The compliance evaluation inspection is satisfactory.Mr. Hughes is doing a very good job at operating the
facility. If you have any questions, please contact George Smith or me at(336)776-9800.
Sincerely, /
Sherri V Knight,PE, Regional Supervisor
Water Quality Regional Operations Section
Division of Water Resources,NCDEQ
cc: I�P�S'Uriit�Joe=Eorporon�
WSRO Files
United States Environmental Protection Agency Form Approved.
EPA Washington,D C.20460 OMB No.2040-0057
Water Compliance Inspection Report Approval expires 8-31-98
Section A-National Data System Coding(i.e,PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 IN 1 2 15 1 3 I NCO032212 111 121 16/03/23 I17 18 JCJ 19,1 c 1 201 I
21111111 111111111111111111 1111111 11111111111 166
Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA -------Reserved- --
67 70 J 71 72 NJ 73 I 74
751 1 1 I 1 1 I80X
Section B•Facility Data
Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Date Permit Effective Date
POTW name and NPDES permit Number) 10.35AM 16/03/23 13/02/01
Yonahlossee WWTP
NCSR 1102 Exit Time/Date Permit Expiration Date
Boone NC 28607 11 02AM 16/03/23 17/09/30
Name(s)of Onsite Representatives)/Titles(s)/Phone and Fax Number(s) Other Facility Data
Brandon K Hughes/ORC/828-260-5213/
Name,Address of Responsible Official/Title/Phone and Fax Number
Contacted
Jadd Wesley Brewer,PO Box 1167 Banner Elk NC
No
2860411671/828-898-6277/8288986255
Section C:Areas Evaluated During Inspection(Check only those areas evaluated).
Permit ® Flow Measurement Operations&Maintenance ® Records/Reports
Self-Monitoring Program ■ Facility Site Review Effluent/Receiving Waters
Section D Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s)and Signature(s)of Inspector(s) Agency/Office/Phone and Fax Numbers Date
George S Smith WSRO WQ//336-776-9700/
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
EPA Form 3560-3(Rev 9-94)Previous editions are obsolete.
Page# 1
Permit: NCO032212 Owner-Facility: Yonahlos see WWTP
Inspection Date: 03/23/2016. Inspection Type: Compliance Evaluation
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑
Does the facility analyze process control parameters, for ex MLSS, MCRT, Settleable ❑ ❑ e ❑
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment:
Permit Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ 0 ❑
application?
Is the facility as described in the permit? ❑ ❑ ❑
#Are there any special conditions for the permit? M ❑ ❑ ❑
Is access to the plant site restricted to the general public? e ❑ ❑ ❑
Is the inspector granted access to all areas for inspection? M ❑ ❑ ❑
Comment: Temporary means of disinfection
Record Keeping Yes No NA NE
Are records kept and maintained as required by the permit? 0 ❑ ❑ ❑
Is all required information readily available, complete and current? 0 ❑ ❑ ❑
Are all records maintained for 3 years(lab. reg. required 5 years)? ® ❑ ❑ ❑
Are analytical results consistent with data reported on DMRs? 0 ❑ ❑ ❑
Is the chain-of-custody complete? S ❑ ❑ ❑
Dates,times and location of sampling
Name of individual performing the sampling .
Results of analysis and calibration
Dates of analysis
Name of person performing analyses
Transported COCs
Are DMRs complete. do they include all permit parameters? 0 ❑ ❑ ❑
Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ M ❑
(If the facility is=or>5 MGD permitted flow) Do they operate 24/7 with a certified operator ❑ ❑ M ❑
on each shift?
Is the ORC visitation log available and current? ❑ ❑ ❑
Is the ORC certified at grade equal to or higher than the facility classification? M ❑ ❑ ❑
Is the backup operator certified at one grade less or greater than the facility classification? 0 ❑ ❑ ❑
Is a copy of the current NPDES permit available on site? 0 ❑ ❑ ❑
Page# 3
i'
Permit: NCO032212 Owner-Facility: YonaMossee WWfP
Inspection Date: 03/23/2016 Inspection Type: Compliance Evaluation
Record Keeping Yes No NA NE
Facility has copy of previous year's Annual Report on file for review? ❑ ❑ 0 ❑
Comment:
Flow Measurement- Effluent Yes No NA NE
#Is flow meter used for reporting? 0 ❑ ❑ ❑
Is flow meter calibrated annually? 0 ❑ ❑ ❑
Is the flow meter operational? 0 ❑ ❑ ❑
(If units are separated) Does the chart recorder match the flow meter? ❑ ❑ ❑ 0
Comment.
Aeration Basins Yes No NA NE
Mode of operation Ext.Air
Type of aeration system Diffused
Is the basin free of dead spots? 0 ❑ ❑ ❑
Are surface aerators and mixers operational? ❑ ❑ 0 ❑
Are the diffusers operational? 0 ❑ ❑ ❑
Is the foam the proper color for the treatment process? 0 ❑ ❑ ❑
Does the foam cover less than 25%of the basin's surface? 0 ❑ ❑ ❑
Is the DO level acceptable? -. 0 ❑ ❑ ❑
Is the DO level acceptable?(1 0 to 3.0 mg/1) ❑ ❑ ❑ 0
Comment:
Secondary Clarifier Yes No NA NE
Is the clarifier free of black and odorous wastewater? 0 ❑ ❑ ❑
Is the site free of excessive buildup of solids in center well of circular clarifier? 0 ❑ ❑ ❑
Are weirs level? 0 ❑ ❑ ❑
Is the site free of weir blockage? 0 ❑ ❑ ❑
Is the site free of evidence of short-circuiting? 0 ❑ ❑ ❑
Is scum removal adequate? 0 ❑ ❑ ❑
Is the site free of excessive floating sludge? 0 ❑ ❑ ❑
Is the drive unit operational? ❑ ❑ 0 ❑
Is the return rate acceptable(low turbulence)? ❑ ❑ ❑ 0
Is the overflow clear of excessive solids/pin floc? 0 ❑ ❑ ❑
Page# 4
t
Permit: NC0032212 Owner-Facility: Yonahlossee WWfP
Inspection Date: 03/23/2016 Inspection Type: Compliance Evaluation
Secondary Clarifier Yes No NA NE
Is the sludge blanket level acceptable?(Approximately Y.of the sidewall depth) ❑ ❑ ❑ N
Comment:
Disinfection - UV Yes No NA NE
Are extra UV bulbs available on site? N ❑ ❑ ❑
Are UV bulbs clean? ❑ ❑ ❑ 0
Is UV Intensity adequate? M ❑ ❑ ❑
Is transmittance at or above designed level? ❑ ❑ ❑ M
Is there a backup system on site? 0 ❑ ❑ ❑
Is effluent clear and free of solids? M ❑ ❑ ❑
Comment: