HomeMy WebLinkAboutNC0032212_Compliance Evaluation Inspection_20160412 PAT MCCRORY /;rn,nrr,r �rY DONALD R. VAN DER VAART r S'e..r erar,. Water Resources "-S-. JAY Z 1 M M-E R M A N ENVIRONMEN rAL OUAUTY UIYPPIOY April 12, 2016 Mr. Jadd Brewer WaterQ tS'uali Services,Inc. P.O. Box 1167 REDENEDINCDE(�D Banner Elk,NC 28604-1167 APR 13 2016 SUBJECT: Compliance Evaluation Inspection Water Quality ion Yonahlossee WWTP Permitting NPDES Permit#NCO032212 Watauga County Dear Mr. Brewer: A Compliance Evaluation Inspection was performed on the facility by George Smith, along with April Norton on March 23, 2016.Mr. Brandon Hughes, ORC, Grade II; Mr. Jadd Brewer,Back-up ORC, Grade III; were present for the inspection. The inspection is comprised of an overall evaluation of the facilities equipment, capability to meet effluent limits, and compliance with the NPDES permit. Permit Your NPDES permit became effective February 1, 2013 and expires September 30, 2017.•This office received a copy of the letter dated February 17, 2016 requesting the facility be changed from composite to grab sampling. The permitted flow for this facility will need to be changed from 0.04 MGD to 0.03 MGD. Records &Reports The operator and plant log are printed on a form showing visitation times and plant conditions.The log will be examined more thoroughly during the next year inspection for visitation times,observations,and process control. The chain of custody forms and calibrations records are in good order. Field test calibrations were documented for pH,Temperature, and Dissolved Oxygen. Facility Site Review The treatment plant is not open to the environment.The building has fallen down.The plant can be visually operated and maintained in a safe manner. The left-side of the treatment unit is not operated. The equalization basin is located in a separate building.The pumps are working. This treatment unit is still located in a building with poor lighting. The aeration basin diffusers are working. The blower motors were operational. A 1-inch manual barscreen is manually cleaned. It protects the plant. State of North Carolina I Environmental Quality I Water Resources 450 West Hanes Mill Road,Swte 300,Winston-Salem,NC 27105 Phone 336-776-9800\Internet:www.ncdenr gov The 10-foot circular clarifier had no solids coming over the weirs. The blanket height in the 10-foot deep clarifier is not generally measured. Settleability is used to judge process control conditions. The Trojan 200 UV disinfection unit is working. The indicator lights are on. Flow Measurement The recording flow measuring device was calibrated by B.W.Allen on October 8,2015. Laboratory Water Quality Lab, Inc. 4544 is certified, and performed the following field tests: Dissolved Oxygen, pH, and Temperature. The pH meter is calibrated with a two-point buffer of 4& 10, and check with a pH 7 buffer. A calibration log was kept for pH and dissolved oxygen, and total residual chlorine. Temperature is traceable to NIST. Effluent/Receiving Waters The effluent, which discharges to Lance Creek, Class C; Trout waters, was clear, no color, no solids, no odor.The stream does not appear to be impacted. Operations &Maintenance The Class II facility was maintained by the following contingent:Mr.Brandon Hughes,ORC, Grade II and Mr. Jadd Brewer,Back-up ORC, Grade III. Self-Monitoring Program A time composite sample is performed at 100 mL/hr. The NPDES flow proportional requirement will not be examined at this time. The NPDES Unit is reviewing the request to change the permit from flow proportional sample to grab sample. A review of the monthly self-monitoring reports from August 2015 through January 2016 did not show any limit violations. The compliance evaluation inspection is satisfactory.Mr. Hughes is doing a very good job at operating the facility. If you have any questions, please contact George Smith or me at(336)776-9800. Sincerely, / Sherri V Knight,PE, Regional Supervisor Water Quality Regional Operations Section Division of Water Resources,NCDEQ cc: I�P�S'Uriit�Joe=Eorporon� WSRO Files United States Environmental Protection Agency Form Approved. EPA Washington,D C.20460 OMB No.2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A-National Data System Coding(i.e,PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 15 1 3 I NCO032212 111 121 16/03/23 I17 18 JCJ 19,1 c 1 201 I 21111111 111111111111111111 1111111 11111111111 166 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA -------Reserved- -- 67 70 J 71 72 NJ 73 I 74 751 1 1 I 1 1 I80X Section B•Facility Data Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 10.35AM 16/03/23 13/02/01 Yonahlossee WWTP NCSR 1102 Exit Time/Date Permit Expiration Date Boone NC 28607 11 02AM 16/03/23 17/09/30 Name(s)of Onsite Representatives)/Titles(s)/Phone and Fax Number(s) Other Facility Data Brandon K Hughes/ORC/828-260-5213/ Name,Address of Responsible Official/Title/Phone and Fax Number Contacted Jadd Wesley Brewer,PO Box 1167 Banner Elk NC No 2860411671/828-898-6277/8288986255 Section C:Areas Evaluated During Inspection(Check only those areas evaluated). Permit ® Flow Measurement Operations&Maintenance ® Records/Reports Self-Monitoring Program ■ Facility Site Review Effluent/Receiving Waters Section D Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s)and Signature(s)of Inspector(s) Agency/Office/Phone and Fax Numbers Date George S Smith WSRO WQ//336-776-9700/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3(Rev 9-94)Previous editions are obsolete. Page# 1 Permit: NCO032212 Owner-Facility: Yonahlos see WWTP Inspection Date: 03/23/2016. Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑ Does the facility analyze process control parameters, for ex MLSS, MCRT, Settleable ❑ ❑ e ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ 0 ❑ application? Is the facility as described in the permit? ❑ ❑ ❑ #Are there any special conditions for the permit? M ❑ ❑ ❑ Is access to the plant site restricted to the general public? e ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? M ❑ ❑ ❑ Comment: Temporary means of disinfection Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? 0 ❑ ❑ ❑ Is all required information readily available, complete and current? 0 ❑ ❑ ❑ Are all records maintained for 3 years(lab. reg. required 5 years)? ® ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? 0 ❑ ❑ ❑ Is the chain-of-custody complete? S ❑ ❑ ❑ Dates,times and location of sampling Name of individual performing the sampling . Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete. do they include all permit parameters? 0 ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ M ❑ (If the facility is=or>5 MGD permitted flow) Do they operate 24/7 with a certified operator ❑ ❑ M ❑ on each shift? Is the ORC visitation log available and current? ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? M ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility classification? 0 ❑ ❑ ❑ Is a copy of the current NPDES permit available on site? 0 ❑ ❑ ❑ Page# 3 i' Permit: NCO032212 Owner-Facility: YonaMossee WWfP Inspection Date: 03/23/2016 Inspection Type: Compliance Evaluation Record Keeping Yes No NA NE Facility has copy of previous year's Annual Report on file for review? ❑ ❑ 0 ❑ Comment: Flow Measurement- Effluent Yes No NA NE #Is flow meter used for reporting? 0 ❑ ❑ ❑ Is flow meter calibrated annually? 0 ❑ ❑ ❑ Is the flow meter operational? 0 ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ ❑ 0 Comment. Aeration Basins Yes No NA NE Mode of operation Ext.Air Type of aeration system Diffused Is the basin free of dead spots? 0 ❑ ❑ ❑ Are surface aerators and mixers operational? ❑ ❑ 0 ❑ Are the diffusers operational? 0 ❑ ❑ ❑ Is the foam the proper color for the treatment process? 0 ❑ ❑ ❑ Does the foam cover less than 25%of the basin's surface? 0 ❑ ❑ ❑ Is the DO level acceptable? -. 0 ❑ ❑ ❑ Is the DO level acceptable?(1 0 to 3.0 mg/1) ❑ ❑ ❑ 0 Comment: Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? 0 ❑ ❑ ❑ Is the site free of excessive buildup of solids in center well of circular clarifier? 0 ❑ ❑ ❑ Are weirs level? 0 ❑ ❑ ❑ Is the site free of weir blockage? 0 ❑ ❑ ❑ Is the site free of evidence of short-circuiting? 0 ❑ ❑ ❑ Is scum removal adequate? 0 ❑ ❑ ❑ Is the site free of excessive floating sludge? 0 ❑ ❑ ❑ Is the drive unit operational? ❑ ❑ 0 ❑ Is the return rate acceptable(low turbulence)? ❑ ❑ ❑ 0 Is the overflow clear of excessive solids/pin floc? 0 ❑ ❑ ❑ Page# 4 t Permit: NC0032212 Owner-Facility: Yonahlossee WWfP Inspection Date: 03/23/2016 Inspection Type: Compliance Evaluation Secondary Clarifier Yes No NA NE Is the sludge blanket level acceptable?(Approximately Y.of the sidewall depth) ❑ ❑ ❑ N Comment: Disinfection - UV Yes No NA NE Are extra UV bulbs available on site? N ❑ ❑ ❑ Are UV bulbs clean? ❑ ❑ ❑ 0 Is UV Intensity adequate? M ❑ ❑ ❑ Is transmittance at or above designed level? ❑ ❑ ❑ M Is there a backup system on site? 0 ❑ ❑ ❑ Is effluent clear and free of solids? M ❑ ❑ ❑ Comment: I Page# 5