Loading...
HomeMy WebLinkAboutNC0032131_Compliance Evaluation Inspection_20150722 • AVA NCDENR North Carolina Department of Environment and Natural Resources Pat McCrory Donald R. van der Vaart Governor Secretary July 22, 2015 Mr. Chris Robbins, President Tweetsie Railroad RECEIVED/DENRIDWR 300 Tweetsie Railroad Lane Blowing Rock, NC 28605 JUL 2 7 2015 SUBJECT: Compliance Evaluation Inspection(CEI) Water Quality Tweetsie Railroad WWTP Permitting Section NPDES Permit#NC0032131 Watauga County Dear Mr. Robbins: A Compliance Evaluation Inspection was performed on the subject facility by George Smith on July 17, 2015; Mr. Brian Banner, ORC was present for the inspection. The inspection is comprised of an overall evaluation in order to document compliance and noncompliance of: facilities equipment, capability to meet effluent limits, and terms & conditions with the NPDES permit. Permit Your permit became effective April 1, 2011 and expires on March 31, 2016. You should expect to receive a permit renewal letter with an application later this year. Records & Reports An Operators Log is maintained that records daily plant observations. A Lift Station Log is maintained that records date of inspections and conditions. A Flow Recording Log documents flow readings and the totalizer. A Monthly Data Log records effluent measurements, such as: Temperature, pH, Dissolved Oxygen, and Total Residual Chlorine. The records and reports are organized and neatly kept. Facility Site Review The facility grounds are well kept. A secure fence surrounds the plant. 450 W.Hanes Mill Road,Winston-Salem,North Carolina 27105 phi e_9�F_7)g_gR0 1_Internet_ vnC[1_e_nrq • There are two treatment trains in the facility. The left train is not operated and has duckweed covering the ` surface. There is an influent splitter. All the influent flow is directed to the treatment train on the right side of the plant. The equalization basin appears to have sufficient aeration. The right aeration basin mixed liquor is black in color. There was a slight septic odor. The plant is septic. The course bubble diffusers are delivering aeration. There is foam covering less than 10% of the basin. On July 20, 2015 Mr. Banner reported that the aeration basin was a brown color. • The blowet motors and electric panels are in very good condition. The secondary clarifier effluent is cloudy and no odor. There is some straggler flock. Chlorine tablets at+used iii the Sanuril 4-tube unit. The chlorine contact basin appears to be maintained. The 30° v-notch weir is located at the end of this treatment unit. Norweco tablets are used for disinfection. Norweco tablets are used for dechlorination, and are placed in 3-tubes of the unit, which is located at the effluent aeration basin. During the inspection, it was discussed that the lift station may be holding the wastewater too long. Mr. Banner suggested that the floats be adjusted to pump the station on a more frequent basis. This office recommends that the diffusers in the aeration basin be inspected during the winter months. Fine bubble diffusers maywork well at this facility. Effluent/Receiving Waters The effluent to the Middle Fork South Fork New River, Class WS-W - Trout + waters was clear, no color, no solids, and no odor. Flow Measurement The flow measuring device was calibrated by Don Williams Electric on July 20, 2015. This office recommends that paper documentation be kept, which documents the calibration procedure. The flow is measured using an Isco 3010 ultrasonic sensor to measure the head in front of a 30° v-notch weir. Self-Monitoring Program A review of the monthly self-monitoring reports from July 2014 through March 2015 showed no limit violations. An Isco Model 5800 composite sampler was installed. It samples flow proportion at 100 mL/ 500 gallons. The plant does not receive much flow. • Laboratory Tweetsie Railroad is a field certified lab#5663. The calibrations for pH and Dissolved Oxygen are recorded. The Town performs the following field tests: pH, Dissolved Oxygen, Total Residual Chlorine, and Temperature. These tests are recorded on the daily monitoring report and must be field certified. A Hach DR1900 spectrophotometer is used for TRC analysis. The annual calibration curve was performed on August 25, 2014. A Hach SensIon 156 is used for pH, DO, and Temperature. Operations & Maintenance The facility was well maintained by the following contingent: Brian Banner, ORC, Grade II; Tim Everhart, back-up ORC, Grade III. The plant is operated by observation. There is no process tests performed at this time. Sludge Handling/Disposal The digester is approximately half full and residuals are hauled by A-One Services. The compliance evaluation inspection is satisfactory. If you have any questions please contact George Smith or me at(336) 776-9800. Sincerely, .,014t/ibrrACi'"c W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Division of Water Resources,NCDENR cc: Mr.Brian Banner,P.O.Box 2225,Blowing Rock,NC 28605 Water Quality Permitting—Charles Weaver WSRO Files d United States Environmental Protection Agency Form Approved. EPA Washington,0.C.20460 OMB No.2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A:National Data System Coding(i.e.,PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 El 2 3 NC0032131 111 12 15/07/17 117 18 LI 19 [ j 2011 211111 l 11111111 jI I I I II I II I I I I 1111 1111111 ( l I I Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 GA -- Reserved 671 I 701,LJ it I 71 Iti 1 72 I ti I 73 I 174 751 1 1 1 1 1 1 180 Section B:FacilityData LJ [ ` Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 09:48AM 15/07/17 11/04/01 Tweetsie Railroad Exit Time/Date Permit Expiration Date US Hwy 321 221s Boone 10:45AM 15/07/17 16/03/31 Blowing Rock NC 28605 Name(s)of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data /// Brian Keith Banner/ORC/828-719-1061/ Name,Address of Responsible Official/Title/Phone and Fax Number Contacted Chris B Robbins,PO Box 388 Blowing Rock NC 28605Np/828-264-9061/ No Section C:Areas Evaluated During Inspection(Check only those areas evaluated) Permit II Flow Measurement • Operations&Maintenance El Records/Reports di Self-Monitoring Program 1111 Facility Site Review al Effluent/Receiving Waters • Laboratory Section D:Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s)and Signature(s)of Inspector(s) Agency/Office/Phone and Fax Numbers Date George S Smith WSRO WQ//336-776-9700/ �1 0)y..,�0IS r • Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3(Rev 9-94)Previous editions are obsolete. Page# 1 Permit: NC0032131 Owner-Facility: Tweetsie Railroad inspection Date: 07/17/2015 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? • 0 0 0 Does the facility analyze process control parameters,for ex: MLSS,MCRT, Settleable 0 • 0 0 Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Operates visually Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new 0 0 • 0 application? Is the facility as described in the permit? • 0 0 0 #Are there any special conditions for the permit? 0 • 0 0 Is access to the plant site restricted to the general public? U 0 0 0 Is the inspector granted access to all areas for inspection? • 0 0 0 Comment: Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? • 0 0 0 Is all required information readily available, complete and current? • 0 0 0 Are all records maintained for 3 years(lab. reg.required 5 years)? • 0 0 0 Are analytical results consistent with data reported on DMRs? • 0 0 0 Is the chain-of-custody complete? • 0 0 0 Dates, times and location of sampling • Name of individual performing the sampling • Results of analysis and calibration • Dates of analysis • Name of person performing analyses Transported COCs • Are DMRs complete: do they include all permit parameters? • 0 0 0 Has the facility submitted its annual compliance report to users and DWQ? 0 0 • 0 (If the facility is=or>5 MGD permitted flow)Do they operate 24/7 with a certified operator 0 0 • 0 on each shift? Is the ORC visitation log available and current? • 0 0 0 Is the ORC certified at grade equal to or higher than the facility classification? U 0 0 0 Is the backup operator certified at one grade less or greater than the facility classification? • 0 0 0 Is a copy of the current NPDES permit available on site? • 0 0 0 Page# 3 r Permit NC0032131 Owner-Facility: Tweetsie Railroad Inspection Date: 07/17/2015 Inspection Type: Compliance Evaluation Record Keeping Yes No NA NE Facility has copy of previous year's Annual Report on file for review? ❑. 0 • 0 Comment: Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? • 0 0 0 Are the receiving water free of foam other than trace amounts and other debris? • 0 0 0 If effluent (diffuser pipes are required) are they operating properly? 0 0 II ❑ Comment: Flow Measurement-Effluent Yes No NA NE #Is flow meter used for reporting? 0 0 0 0 Is flow meter calibrated annually? 0 0 0 0 Is the flow meter operational? 0 0 0 0 (If units are separated)Does the chart recorder match the flow meter? 0 0 0. 0 Comment: Pump Station -Influent Yes No NA NE Is the pump wet well free of bypass lines or structures? 0 ❑ 0 0 Is the wet well free of excessive grease? 0 ❑ 0 0 Are all pumps present? 0 0 0 0 Are all pumps operable? 0 0 0 0 Are float controls operable? 0 0 0 0 Is SCADA telemetry available and operational? 0 0 0 0 Is audible and visual alarm available and operational? 0 0 ❑ 0 Comment: Bar Screens Yes No NA NE Type of bar screen a.Manual • b.Mechanical 0 Are the bars adequately screening debris? • ❑ 0 0 Is the screen free of excessive debris? • ❑ ❑ 0 Is disposal of screening in compliance? • 0 0 0 Page# 4 Permit: NC0032131 Owner-Facility: Tweetsie Railroad Inspection Date: 07/17/2015 Inspection Type: Compliance Evaluation Bar Screens Yes No NA NE Is the unit in good condition? • 0 0 0 Comment: Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? • 0 0 0 Is the site free of excessive buildup of solids in center well of circular clarifier? • 0 0 0 Are weirs level? • 0 0 0 Is the site free of weir blockage? • 0 0 0 Is the site free of evidence of short-circuiting? • 0 0 0 Is scum removal adequate? • 0 0 0 Is the site free of excessive floating sludge? • 0 0 0 Is the drive unit operational? 0 0 • 0 Is the return rate acceptable(low turbulence)? 0 0 0 0 • Is the overflow clear of excessive solids/pin floc? • 0 0 0 Is the sludge blanket level acceptable?(Approximately 1/4 of the sidewall depth) • 0 0 0 • Comment: Aeration Basins Yes No NA NE Mode of operation Ext.Air Type of aeration system Diffused Is the basin free of dead spots? • 0 0 0 Are surface aerators and mixers operational? 0 0 • 0 Are the diffusers operational? • 0 0 0 Is the foam the proper color for the treatment process? 0 • 0 0 Does the foam cover less than 25%of the basin's surface? • 0 0 0 Is the DO level acceptable? 0 • 0 0 Is the DO level acceptable?(1.0 to 3.0 mg/I) 0 0 0 • Comment: basin is black in color, but does not have a strong septic odor. Possible that the lift station was septic. Disinfection-Tablet Yes No NA NE Are tablet chlorinators operational? • 0 0 0 Are the tablets the proper size and type? • 0 0 0 Number of tubes in use? 3 Page# 5 I Permit NC0032131 Owner-Facility: Tvaeetsie Railroad Inspection Date: 07/17/2015 Inspection Type: Compliance Evaluation Disinfection-Tablet Yes No NA NE Is the level of chlorine residual acceptable? 0 0 0 • Is the contact chamber free of growth,or sludge buildup? • ❑ ❑ 0 Is there chlorine residual prior to de-chlorination? 0 0 0 • Comment: Effluent Sampling Yes No NA NE Is composite sampling flow proportional? • 0 0 0 Is sample collected below all treatment units? • 0 0 0 Is proper volume collected? • 0 0 0 Is the tubing clean? • 0 0 0 #Is proper temperature set for sample storage(kept at less than or equal to 6.0 degrees • 0 0 0 Celsius)? Is the facility sampling performed as required by the permit(frequency, sampling type • 0 0 0 representative)? Comment: De-chlorination Yes No NA NE Type of system? Tablet Is the feed ratio proportional to chlorine amount(1 to 1)? • 0 0 0 Is storage appropriate for cylinders? 0 0 • 0 #Is de-chlorination substance stored away from chlorine containers? 0 0 • 0 Comment: Are the tablets the proper size and type? • 0 0 0 Are tablet de-chlorinators operational? • 0 0 ❑ Number of tubes in use? 3 Comment: Page# 6