Loading...
HomeMy WebLinkAboutNC0029602_Compliance Evaluation Inspection_20170118January 18, 2017 Yadkin County Board of Education Attn: Dr. Todd Martin, Superintendent 121 Washington Street Yadkinville, NC 27055 SUBJECT: Compliance Evaluation Inspections Yadkin County Board of Education Wastewater Treatment Plants Yadkin County Dear Dr. Martin: ROY COOPER Governor WILLIAM G. ROSS, JR. Acting Secretary ..JAN 2 4 2017 Water Quality Permitting Section Ron Boone of the Winston Salem Regional Office (WSRO) of the North Carolina Division of Water Resources (DWR or the Division) conducted compliance evaluation inspections at the facilities and corresponding dates specified in the table below: Facility Name NPDES Permit # Date of Inspection Courtne .Elementa School CES NCO029599 December 14, 2016 Forbush Elementary School FES NCO029602 December 14, 2016 Forbush High School FHS NCO071773 December 14, 2016 Starmount High School SHSNCO070459 Logan Creek December 14, 2016 East Bend Elementary School EBES NCO029611 January 12, 2017 The assistance and cooperation of Mitch Long, Operator in Responsible Charge (ORC), was greatly appreciated. Inspection reports are attached for your records and the inspection findings are summarized below. The following table shows important details about each plant:_ Facility Name Plant Type Latitude & Longitude Receiving Stream Receiving'Stream Classification CES Sand Filter 36.067886, 80.602172 Harmon Creek WS -IV EBES Sand Filter 36.213194, 80.509137 Logan Creek C FES Activated Sludge 36.125681, 80.49$559595 80.49 Logan Creek WS -IV FHS Activated Sludge 03, 80.55 088 80.559088 Forbush Creek WS -IV SHS Activated Sludge 36.182031, 80.769535 South Deep Creek WS -III - Nothing Coe pares'r-.,__, State of North Carolina I Environmental Quality 450 West Hanes Mill Road, Suite 300, Winston-Salem, NC 27105 Phone: 336-776-98001 Internet: www.ncdenr.gov 9 SITE REVIEWS Inspection of all five plants revealed no discrepancies, concerns, or violations. It appears that Mr. Long and his backup operator(s) are doing a very good job operating all five plants. The plants are all in good condition and appear to be operating at peak efficiency. Mr. Long and his backups should be congratulated for doing an outstanding job. DOCUMENTATION REVIEWS Additionally, there were no problems noted with Mr. Long's documentation for all five plants. Mr. Long had all the required documentation and it meets all requirements. There were no discrepancies noted in any of the five inspections. Please encourage Mr. Long and Mr. Hinshaw to keep up the good work in ensuring the plants are properly operated and maintained and consistently meeting all terms and conditions of the permits. Please note that in accordance with NC General Statute 143-215.6A, permit violations are subject to civil penalty assessments not to exceed $25,000 per day, per violation. If you have any questions regarding the inspections or this letter, please do not hesitate to contact Mr. Boone or me at 336-776-9800. Thank you for your cooperation in this matter. Sincerely, 'herri V. Knight, P.E. Regional Supervisor Water Quality Regional Operations Division of Water Resources Attachments: 1. BIMS Inspection Reports (x5 — one for each plant) CC: Central Files NPDES Unit WSRO/SWP Files Yadkin County Board of Education Attn: Mitchell Long, Operator in Responsible Charge 121 Washington Street Yadkinville, NC 27055 United States Environmental Protection Agency Form Approved. Washington, D.C. 20460 EPA OMB No. 2040-0057 Water compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 U 2 15 I 3 I NCO029599 111 12 16/12/14 17 18 i C J 19 i s i 20 LJ 211111 1 1 1 1 1 1 II 1 1 I I I I I I I I I I I l i l i i l i i l III I I I D f --- Reserved ----- Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA -----Reserved --- 6772 L_ 73 174 75 1 1 1 1 1 80 71 lil 67 70L_j Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 11:30AM 16/12/14 14/01/01 Courtney Elementary School WWTP Exit Time/Date permit Expiration Date 2529 Courtney -Huntsville 12:15PM 16/12/14 18/12/31 Yadkinville NC 27055 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Mitchell Thomas Long/ORC/336-518-4336/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Mark Matthews,121 Washington St Yadkinville NC 270557725//336-699-44811 No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenance Records/Reports Self -Monitoring Program Facility Site Review Effluent/Receiving Waters Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Ron Boon WSRO WQH336-776-9690/ 62 7 Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers . Date / c6t1� l l 1s, //T EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day - Inspection Type 31 NCO029599 I11 12 16/12/14 17 18 1 C 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Please refer to the attached inspection summary letter. Page# I Permit: NCO029599 Owner - Facility: Courtney Elementary School WWTP Inspection Date: 12/14/2016 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable 0 ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: None Permit Yes No -NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ 0 ❑ application? 0 ❑ ❑ ❑ Is the facility as described in the permit? 0 ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ 0 ❑ ❑ Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? 0 ❑ ❑ ❑ Comment: None Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? M ❑ ❑ ❑ Is all required information readily available, complete and current? 0 ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? 0 ❑ ❑ ❑ Are analytical results consistent with data reported on DM Rs? M ❑ ❑ ❑ Is the chain -of -custody complete? M ❑ ❑ ❑ Dates, times and location of sampling Name of individualperforming the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCl Are MRS complete: do they include all permit parameters? M ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ M ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator ❑ 0 ❑ ❑ on each shift?. Is the ORC visitation log available and current? ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? ❑ ❑ .❑ Is the backup operator certified at one grade less or greater than the facility classification? ❑ ❑ ❑ Is a copy of the current NPDES permit available on site? M ❑ ❑ ❑ Page# 3 Permit: NC0029599 Owner -Facility: Courtney Elementary School WWTP Inspection Date: 12/14/2016 Inspection Type: Compliance Evaluation Record Keeping Yes No NA NE Facility has copy of previous year's Annual Report on file for review? ❑ ❑ M ❑ Comment: None Effluent Pipe Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Comment: None Flow Measurement - Effluent # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Comment: Water meter used. Disinfection - UV Are extra UV bulbs available on site? Are UV bulbs clean? Is UV intensity adequate?. Is transmittance at or above designed level? Is there a backup system on site? Is effluent clear and free of solids? Comment: None Septic Tank (If pumps are used) Is an audible and visual alarm operational? Is septic tank pumped on a schedule? Are pumps or syphons operating properly? Are high and low water alarms operating properly? Comment: None Sand Filters (Low rate) Yes No NA NE ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ■ ❑ Yes No NA NE ■ ❑ 1:111 ❑ ■ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ■ ❑ Yes No NA NE • ❑ ❑ ❑ • ❑ ❑ ❑ ■ ❑ ❑ ❑ M ❑ ❑ ❑ M ❑ ❑ ❑ ■ ❑ ❑ ❑ Yes No NA NE ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ .❑ ❑ Yes No NA NE Page# 4 Permit: NCO029599 Owner- Facility: Courtney Elementary School WWfP Are field parameters performed by certified personnel or laboratory? N Inspection Date: 12/14/2016 Inspection Type: Compliance Evaluation ❑ Are all other parameters(excluding field parameters) performed by a certified lab? M Sand Filters (Low rate) Yes No NA NE (If pumps are used) Is an audible and visible alarm Present and operational? ❑ 0 ❑ ❑ Is the distribution box level and watertight? ❑ ❑ ❑ 0 Is sand filter free of ponding? N ❑ ❑ ❑ Is the sand filter effluent re -circulated at a valid ratio? N ❑ ❑ ❑ # Is the sand filter surface free of algae or excessive vegetation? Incubator (BOD) set to 20.0 degrees Celsius +/-1.0 degrees? ❑ ❑ ❑ # Is the sand filter effluent re -circulated at a valid ratio? (Approximately 3 to 1) 0 ❑ ❑ ❑ Comment: None Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? N ❑ ❑ ❑ Are all other parameters(excluding field parameters) performed by a certified lab? M ❑ ❑ ❑ # Is the facility using a contract lab? M ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees ❑ ❑ ❑ 0 Celsius)? - ❑ ❑ ❑ M Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? ❑ ❑ ❑ 0 Incubator (BOD) set to 20.0 degrees Celsius +/-1.0 degrees? ❑ ❑ ❑ 0 Comment: None Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ❑ ❑ 0 ❑ Is sample collected below all treatment units? ❑ ❑ ❑ Is proper volume collected? ❑ ❑ ❑ Is the tubing clean? ❑ ❑ N ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees ❑ ❑ ❑ M Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type 0 ❑ ❑ ❑ representative)? Comment: None Page# 5 United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31 -98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 15 I 3 I N00029611 111 12 17/01/12 17 18 I S I 19 I c) . 20I j 211111 1 1 1 1 1 111 1 1 1 1 1 1 1 1 I I I I I I 1 I I I 1 1 H 1111 1 1 1 1 1 16 Inspection Work Days Facility Self -Monitoring Evaluation Rating 131 QA ---Reserved — Reserved67 67701 I 71 I I 72 I N 731 I 174 751 I I I 1__H81 LJ I—I I I I L!_ Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 12:00PM 17/01/12 14/01/01 East Bend Elementary School WWTP ExitTimelDate Permit Expiration Date NC Hwy 67 E 01:OOPM 17/01/12 18!12/31 East Bend NC 27018 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Mitchell Thomas Long/ORC/336-518-4336/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Mark Matthews, 121 Washington StYadkinville NC 270557725//336-699-4481/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit N Flow Measurement Operations & Maintenance Records/Reports Self -Monitoring Program N Facility Site Review Effluent/Receiving Waters Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Ron Boone WSRO WQ//336-776-9690/ Min Xiao WSRO WQ//336769800/ ® �/7 Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date a6% ��� 1 �� 1 f� 7, EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type 31 NCO029611 I11 12 17/01/12 17 1811 11-1„ Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Please refer to the attached inspection summary letter. Page# Permit: NCO029611 Owner -Facility: East Bend Elementary School WWrP Inspection Date: 01/12/2017 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? M ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: None Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ M ❑ application? M. ❑ ❑ ❑ Is the facility as described in the permit? 0 ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ ❑ ❑ ❑ Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? 0 ❑ ❑ ❑ Comment: None Record Keepina Yes No NA NE Are records kept and maintained as required by the permit? M ❑ ❑ ❑ Is all required information readily available, complete and current? M. ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? 0 ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? M ❑ ❑ ❑ Is'the chain -of -custody complete? M ❑ ❑ ❑ Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? 0 ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ 0 ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator ❑ 0 ❑ ❑ on each shift? Is the ORC visitation log available and current? ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? M ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility classification? M ❑ ❑ ❑ Is a copy of the current NPDES permit available on site? 0 ❑ ❑ ❑ Page# 3 Permit: NC0029611 Owner- Facility: East Bend Elementary School WWTP Inspection Date: 01/12/2017 Inspection Type: Compliance Evaluation Record Keeping Yes No NA NE Facility has copy of previous year's Annual Report on file for review? ❑ ❑ 0 ❑ Comment: None Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? 0 ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? 0 ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ 0 ❑ Comment: None Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? N ❑ ❑ ❑ Is flow meter calibrated annually? ❑ N ❑ ❑ Is the flow meter operational? ■ ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ ® ❑ Comment: School's potable water flow meter is used to determine flow to and out of UWVfP. Pump Station - Effluent Yes No NA NE Is the pump wet well free of bypass lines or structures? N ❑ ❑ ❑ Are all pumps present? 0 ❑ ❑ ❑ Are all pumps operable? M ❑ ❑ ❑ Are float controls operable? 0 ❑ ❑ ❑ Is SCADA telemetry available and operational? ❑ 0 ❑ ❑ Is audible and visual alarm available and operational? 0 ❑ ❑ ❑ Comment: None Disinfection - UV Yes No NA NE Are extra UV bulbs available on site? N ❑ ❑ ❑ Are UV bulbs clean? _ M ❑ ❑ ❑ Is UV intensity adequate? 0 ❑ ❑ ❑ Is transmittance at or above designed level? ❑ ❑ ❑ Is there a backup system on site? 0 ❑ ❑ ❑ Is effluent clear and free of solids? 0 ❑ ❑ ❑ Comment: None Page# 4 Permit: NCO029611 Owner- Facility: East Bend Elementary School WWfP Inspection Date: 01/12/2017 Inspection Type: Compliance Evaluation Septic Tank Yes No NA NE (If pumps are used) Is an audible and visual alarm operational? 0 ❑ ❑ ❑ Is septic tank pumped on a schedule? ❑ ❑ ❑ ❑ Are pumps or syphons operating properly? 0 ❑ ❑ ❑ Are high and low water alarms operating properly? 0 ❑ ❑ ❑ Comment: None Sand Filters (Low rate) Yes No NA NE (If pumps are used) Is an audible and visible alarm Present and operational? ❑ N ❑ ❑ Is the distribution box level and watertight? ❑ ❑ ❑ 0 Is sand filter free of ponding? N ❑ ❑ ❑ Is the sand filter effluent re-dirculated at a valid ratio? ❑ ❑ ❑ ❑ # Is the sand filter surface free of algae or excessive vegetation? M ❑ ❑ ❑ # Is the sand filter effluent re -circulated at a valid ratio? (Approximately 3 to 1) . 0 ❑ ❑ ❑ Comment: None Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? 0 ❑ ❑ ❑ Are all other parameters(excluding field parameters) performed by a certified lab? M ❑ ❑ ❑ # Is the facility using a contract lab? 0 ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees ❑ ❑ ❑ 0 Celsius)? ❑ ❑ ❑ M Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? ❑ ❑ ❑ 0 Incubator (BOD) set to 20.0 degrees Celsius +/-1.0 degrees? ❑ ❑ ❑ M Comment: None Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ❑ ❑ N ❑ Is sample collected below all treatment units? 0 ❑ ❑ ❑ Is proper volume collected? N ❑ ❑ ❑ Is the tubing clean? 0 ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees ❑ ❑ ❑ M Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type 0 ❑ ❑ ❑ representative)? Page# Permit: NC0029611 Inspection Date: 01/12/2017 Effluent Sampling Comment: None Owner - Facility: East Bend Elementary School 4WVT'P ��- Inspection Type: Compliance Evaluation Yes No NA NE Page# United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-96 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 2 15 1 3 I N00029602 I11 12 16/12/14 17 18 C I 19 I c I 20I 211IIIII IIIIIII�I II I II IIII I I II III IIIIIII (III r6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------Reserved 671 70 I I 71 Lj 72 � �, � 73I ILJI74 75LJ_LL 80 L� L � L Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 11:30AM 16/12/14 14/01/01 Forbush Elementary School WWTP Exit Time/Date permit Expiration Date 1400 Bloomtown Rd - 12:15PM 16/12/14 18/12/31 East Bend NC 27018 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data 111 Mitchell Thomas Long/ORC/336-518-4336/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Mark Matthews,121 Washington StYadkinville NC 270557725//336-699-4481/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenance Records/Reports Self -Monitoring Program Sludge Handling Disposal Facility Site Review Effluent/Receiving Waters Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Ron Boone WSRO WQ//336-776-9690/ Signature of Management Q A R;ev�iew_Aer/Agency/Office/Phone and Fax Numbers Date /Y/ EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day 31 NCO029602 I11 12 16/12/14 17 Inspection Type 18 JCJ Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Please refer to the attached inspection summary letter. Page# Permit: NCO029602 Owner -Facility: Forbush Elementary School WWTP Inspection Date: 12/14/2016 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? M ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: None Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ M ❑ application? M ❑ ❑ ❑ Is the facility as described in the permit? 0 ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ ❑ ❑ ❑ Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? 0 ❑ ❑ ❑ Comment: None Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? 0 ❑ ❑ ❑ Is all required information readily available, complete and current? M ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? 0 ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? 0 ❑ ❑ ❑ Is the chain -of -custody complete? 0 ❑ ❑ ❑ Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? M ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ 0 ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 2417 with a certified operator ❑ 0 ❑ ❑ on each shift? Is the ORC visitation log available and current? 0 ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? M ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility classification? M ❑ ❑ ❑ Is a copy of the current NPDES permit available on site? 0 ❑ ❑ ❑ Page# 3 r Permit: NC0029602 Owner - Facility: Forbush Elementary School WWTP Inspection Date: 12/14/2016 Inspection Type: Compliance Evaluation Record Keeping Yes No NA NE Facility has copy of previous year's Annual Report on file for review? ❑ ❑ 0 ❑ Comment: None Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? 0 ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? 0 ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ 0 ❑ Comment: None Flow Measurement - Influent Yes No NA NE # Is flow meter used for reporting? N ❑ ❑ ❑ Is flow meter calibrated annually? ❑ 0 ❑ ❑ Is the flow meter operational? ■ ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ N ❑ Comment: Water meter used. Aerobic Digester Yes No NA NE Is the capacity adequate? 0 ❑ ❑ ❑ Is the mixing adequate? N ❑ ❑ ❑ Is the site free of excessive foaming in the tank? M ❑ ❑ ❑ # Is the odor acceptable? 0 ❑ ❑ ❑ # Is tankage available for properly waste sludge? M ❑ ❑ ❑ Comment: None Bar Screens Yes No NA NE Type of bar screen a.Manual b. Mechanical ❑ Are the bars adequately screening debris? M ❑ ❑ ❑ Is the screen free of excessive debris? N ❑ ❑ ❑ Is disposal of screening in compliance? M ❑ ❑ ❑ Is the unit in good condition? ❑ ❑ ❑ Comment: None Page# 4 Permit: NCO029602 Owner - Facility: Forbush Elementary School VWVTP Inspection Date: 12/14/2016 Inspection Type: Compliance Evaluation Equalization Basins Yes No NA NE Is the basin aerated? 0 ❑ ❑ ❑ Is the basin free of bypass lines or structures to the natural environment? 0 ❑ ❑ ❑ Is the basin free of excessive grease? 0 ❑ ❑ ❑ Are all pumps present? 0 ❑ ❑ ❑ Are all pumps operable? M ❑ ❑ ❑ Are float controls operable? M ❑ ❑ ❑ Are audible and visual alarms operable? 0 ❑ ❑ ❑ # Is basin size/volume adequate? ❑ ❑ ❑ ❑ Comment: None Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? 0 ❑ ❑ ❑ Is the site free of excessive buildup of solids in center well of circular clarifier? 0 ❑ ❑ ❑ Are weirs level? 0 ❑ ❑ ❑ Is the site free of weir blockage? 0 ❑ ❑ ❑ Is the site free of evidence of short-circuiting? N ❑ ❑ ❑ Is scum removal adequate? N ❑ ❑ ❑ Is the site free of excessive floating sludge? 0 ❑ ❑ ❑ Is the drive unit operational? ❑ ❑ 0 ❑ Is the return rate acceptable (low turbulence)? 0 ❑ ❑ ❑ Is the overflow clear of excessive solids/pin floc? M ❑ ❑ ❑ Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth) ❑ ❑ ❑ N Comment: None Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Diffused Is the basin free of dead spots? 0 ❑ ❑ ❑ Are surface aerators and mixers operational? ❑ ❑ 0 ❑ Are the diffusers operational? 0 ❑ . ❑ ❑ Is the foam the proper color for the.treatment process? M ❑ ❑ ❑ Does the foam cover less than 25% of the basin's surface? ❑ ❑ ❑ Is the DO level acceptable? ❑ ❑ ❑ 0 Page# 5 Permit: NCO029602 Owner - Facility: Forbush Elementary School WWTP Inspection Date: 12/14/2016 Inspection Type: Compliance Evaluation Aeration Basins Yes No NA NE Is the DO level acceptable?(1.0 to 3.0 mg/1) ❑ ❑ 110 Comment: None Disinfection - UV Yes No NA NE Are extra UV bulbs available on site? 0 ❑ ❑ ❑ Are UV bulbs clean? 0 ❑ ❑ ❑ Is UV intensity adequate? M ❑ ❑ ❑ Is transmittance at or above designed level? M ❑ ❑ ❑ Is there a backup system on site? M ❑ ❑ ❑ Is effluent clear and free of solids? M ❑ ❑ ❑ Comment: None Pumps-RASMAS Yes No NA NE Are pumps in place? M ❑ ❑ ❑ Are pumps operational? 0 ❑ ❑ ❑ Are there adequate spare parts and supplies on site? 0 ❑ ❑ ❑ Comment: None Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? 0 ❑ ❑ ❑ Are all other parameters(excluding field parameters) performed by a certified lab? 0 ❑ ❑ ❑ # Is the facility using a contract lab? M ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees ❑ ❑ ❑ 0 Celsius)? Incubator (Fecal Coliform) set to -44.5 degrees Celsius+/- 0.2 degrees? ❑ ❑ ❑ Incubator (BOD) set to 20.0 degrees Celsius +/-1.0 degrees? ❑ ❑ ❑ M Comment: None Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ❑ ❑ N ❑ Is sample collected below all treatment units? ❑ ❑ ❑ Is proper volume collected? N ❑ ❑ ❑ Is the tubing clean? ❑ ❑ M ❑ Page# 6 Permit: NCO029602 Owner - Facility: Forbush Elementary School WWTP Inspection Date: 12/14/2016 Inspection Type: Compliance Evaluation Effluent Sampling Yes No NA NE # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees ❑ ❑ ❑ 0 Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type ■ ❑ ❑ ❑ representative)? Comment: None Page# 7 United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 E 2 15 1 3 I NCO071773 111 12 16/12/14 17 18 ICI 19 I G j 20 Lj 211111 1 1 111111 1 11 11 1 11 1111 1 1 1 1 1 1 11111111 11 1 1 t66 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved---- — 67 70 I I 71 I ' 72 I N I 73 74 75 80 L� I—! LJJ Section B: FacilityData Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 09:30AM 16/12/14 14/02/01 Forbush High School WWTP 1525 Fallon Rd Exit Time/Date Permit Expiration Date East Bend NC 27018 12:0013M 16/12/14 18/12/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data /// Mitchell Thomas Long/ORC/336-518-4336/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Mark Matthews, 121 Washington StYadkinville NC 270557725//336-699-4481/ No. Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenance Records/Reports Self -Monitoring Program Sludge Handling Disposal Facility Site Review Effluent/Receiving Waters Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Ron Boone WSRO WQ//336-776-96901 /17 6' Signature of ManagementQ A Reviewer Agency/Office/Phone and Fax Numbers Date EPA.Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type 31 NCO071773 I11 12 16/12/14 17 18 I S I Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Please refer to the attached inspection summary letter. Page# Permit: NCO071773 Owner - Facility: Forbush High School WWTP Inspection Date: 12/14/2016 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? • 0 ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: None Permit Yes No NA NE (if the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ M ❑ application? M ❑ ❑ ❑ Is the facility as described in the permit? M ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ - 0 ❑ ❑ Is access to the plant site restricted to the general public? M ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? 0 ❑ ❑ ❑ Comment: None Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? M ❑ ❑ ❑ Is all required information readily available, complete and current? M ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? M ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? 0 ❑ ❑ ❑ Is the chain -of -custody complete? M ❑ ❑ ❑ Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? M ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator ❑ 0 ❑ ❑ on each shift? Is the ORC visitation log available and current? 0 ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? M ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility classification? M ❑ ❑ ❑ Is a copy of the current NPDES permit available on site? M ❑ ❑ ❑ Page# 3 Permit: NC0071773 Owner - Facility: Forbush High School WWTP Inspection Date: 12/14/2016 Inspection Type: Compliance Evaluation Record Keeping Yes No NA NE Facility has copy of previous year's Annual Report on file for review? ❑ ❑ M ❑ Comment: None Effluent Pipe Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Comment: None Flow Measurement - Effluent # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Comment: None Aerobic Digester Is the capacity adequate? Is the mixing adequate? Is the site free of excessive foaming in the tank? # Is the odor acceptable? # Is tankage available for properly waste sludge? Comment: None Bar Screens Type of bar screen a.Manual b.Mechanical Are the bars adequately screening debris? Is the screen free of excessive debris? Is disposal of screening in compliance? Is the unit in good condition? Comment: None Yes No NA NE M ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ M ❑ Yes No NA NE M ❑ ❑ ❑ M ❑ ❑ ❑ M ❑ ❑ ❑ Yes No NA NE ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ M ❑ ❑ ❑ M ❑ ❑ ❑ M ❑ ❑ ❑ Yes No NA NE M ❑ ❑ ❑ ■ ❑ ❑ ❑ Page# 4 Permit NCO071773 Owner - Facility: Inspection Date: 12/14/2016 Inspection Type: Forbush High School WWTP Compliance Evaluation Is the clarifier free of black and odorous wastewater? 0 ❑ Equalization Basins Yes No NA NE Is the basin aerated? 0 ❑ ❑ ❑ Is the basin free of bypass lines or structures to the natural environment? 0 ❑ ❑ ❑ Is the basin free of excessive grease? 0 ❑ ❑ ❑ Are all pumps present? 0 ❑ ❑ ❑ Are all pumps operable? 0 ❑ ❑ ❑ Are float controls operable? 0 ❑ ❑ ❑ Are audible and visual alarms operable? 0 ❑ ❑ ❑ # Is basin size/volume adequate? 0 ❑ ❑ ❑ Comment: None Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? 0 ❑ ❑ ❑ Is the site free of excessive buildup of solids in center well of circular clarifier? 0 ❑ ❑ ❑ Are weirs level? E ❑ ❑ ❑ Is the site free of weir blockage? 0 ❑ ❑ ❑ Is the site free of evidence of short-circuiting? 0 ❑ ❑ ❑ Is scum removal adequate? 0 ❑ ❑ ❑ Is the site free of excessive floating sludge? N ❑ ❑ ❑ Is the drive unit operational? 0 ❑ ❑ ❑ Is the return rate acceptable (low turbulence)? N ❑ ❑ ❑ Is the overflow clear of excessive solids/pin floc? E ❑ ❑ ❑ Is the sludge blanket level acceptable? (Approximately'/ of the sidewall depth) 0 ❑ ❑ ❑ Comment: None Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Diffused Is the basin free of dead spots? N ❑ ❑ ❑ Are surface aerators and mixers operational? ❑ ❑ 0 ❑ Are the diffusers operational? ❑ ❑ ❑ Is the foam the proper color for the treatment process? 0 ❑ ❑ ❑ Does the foam cover less than 25% of the basin's surface? N ❑ ❑ ❑ Is the DO level acceptable? 0 ❑ ❑ ❑ Page# 5 Permit: NCO071773 Owner - Facility: Forbush High School WWTP Inspection Date: 12/14/2016 Inspection Type: Compliance Evaluation Aeration Basins Yes No NA NE Is the DO level acceptable?(1.0 to 3.0 mg/1) 0 ❑ ❑ ❑ Comment: None Disinfection - UV Yes No NA NE Are extra UV bulbs available on site? 0 ❑ ❑ ❑ Are UV bulbs clean? 0 ❑ ❑ ❑ Is UV intensity adequate? M ❑ ❑ ❑ Is transmittance at or above designed level? M ❑ ❑ ❑ Is there a backup system on site? 0 ❑ ❑ ❑ Is effluent clear and free of solids? M ❑ ❑ ❑ Comment: None Pumps -RAS -WAS Yes No NA NE Are pumps in place? N ❑ ❑ ❑ Are pumps operational? 0 ❑ ❑ ❑ Are there adequate spare parts and supplies on site? 0 ❑ ❑ ❑ Comment: None Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? M ❑ ❑ ❑ Are all other parameters(excluding field parameters) performed by a certified lab? M ❑ ❑ ❑ # Is the facility using a contract lab? M ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees ❑ ❑ ❑ 0 Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? ❑ ❑ ❑ Incubator (BOD) set to 20.0 degrees Celsius +/-1.0 degrees? ❑ ❑ 0 ❑ Comment: None Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ❑ ❑ 0 ❑ Is sample collected below all treatment units? N ❑ ❑ ❑ Is proper volume collected? M ❑ ❑ ❑ Is the tubing clean? ❑ ❑ 0 ❑ Page# 6 Permit: NCO071773 Owner - Facility: Forbush High School WWTP Inspection Date: 12/14/2016 Inspection Type: Compliance Evaluation Effluent Samplina Yes No NA NE # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type representative)? Comment: None Upstream / Downstream Sampling Is the facility sampling performed as required by the permit (frequency, sampling type, and sampling location)? Comment: None ❑ ❑ ❑ N N ❑ ❑ ❑ Yes No NA NE N ❑ ❑ ❑ Page# 7 United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 15 I 3 I NCO070459 I11 12 16/12/14 17 18 ICI 19 I G I 20I I 211 11 1 11-I I I I I I I l i l l i l l l l l l i l l l l i l i l l I I I I I I I I r6 Inspection Work Days Facility Self-Monitoring.Evaluation Rating B1 QA ---------Reserved--------- 67 70I I 71I —J I 72 N 73I I 174 75 80 LJ LJ 1 I I Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit.Effective Date POTW name and NPDES permit Number) 10:30AM 16/12/14 14/01/01 Starmount High School WWT'P Exit Time/Date permit Expiration Date 2516 Longtown Rd 11:15AM 16/12/14 18/12/31 Boonville NC 27011 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data /// Mitchell Thomas Long/ORC/336-518-4336/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Mark Matthews, 121 Washington StYadkinvilla NC 270557725//336-6994481/ No Section, C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit N Flow Measurement Operations & Maintenance Records/Reports Self -Monitoring Program E Sludge Handling Disposal Facility Site Review Effluent/Receiving Waters Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary). Name(s) and Signatu of Inspector(s) Agency/Office/Phone and Fax Numbers Date dd Ron Boone WSR0 WQ//336-776-9690/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers /Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day 31 Nco070459 I11 12 16/12/14 17 Inspection Type 18 ICI Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Please refer to the attached inspection summary letter. Page# Permit: NCO070459 Owner - Facility: Starmount High School WWTP Inspection Date: 12/14/2016 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: None Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ 0 ❑ application? M ❑ ❑ ❑ Is the facility as described in the permit? 0 ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ 0 ❑ ❑ Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? 0 ❑ ❑ ❑ Comment: None Record Keeping I Yes No NA NE Are records kept and maintained as required by the permit? M ❑ ❑ ❑ Is all required information readily available, complete and current? M ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? 0 ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? M ❑ ❑ ❑ Is the chain -of -custody complete? 0 ❑ ❑ ❑ Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are MRS complete: do they include all permit parameters? 0 ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ 0 ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator ❑ 0 ❑ ❑ on each shift? Is the ORC visitation log available and current? 0 ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility classification? ❑ ❑ ❑ Is a copy of the current NPDES permit available on site? M ❑ ❑ ❑ Page# 3 Permit: NC0070459 Owner - Facility: Starmount High School WWTP '\ Inspection Date: 12/14/2016 Inspection Type: Compliance Evaluation Record Keeping Yes No NA NE Facility has copy of previous year's Annual Report on file for review? ❑ ❑ 0 ❑ Comment: None Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? N ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? M ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ 0 ❑ Comment: None Flow Measurement - Influent Yes No NA NE # Is flow meter used for reporting? N ❑ ❑ ❑ Is flow meter calibrated annually? ❑ 0 ❑ ❑ Is the flow meter operational? ® ❑ ❑ ❑ (if units are separated) Does the chart recorder match the flow meter? ❑ ❑ 0 ❑ Comment: Water meter used. Aerobic Digester Yes No NA NE Is the capacity adequate? ® ❑ ❑ ❑ Is the mixing adequate? N ❑ ❑ ❑ Is the site free of excessive foaming in the tank? N ❑ ❑ ❑ # Is the odor acceptable? 0 ❑ ❑ ❑ # Is tankage available for properly waste sludge? M ❑ ❑ ❑ Comment: None Bar Screens Yes No NA NE Type of bar screen a.Manual b.Mechanical ❑ Are the bars adequately screening debris? N ❑ ❑ ❑ Is the screen free of excessive debris? 0 ❑ ❑ ❑ Is disposal of screening in compliance? 0 ❑ ❑ ❑ Is the unit in good condition? 0 ❑ ❑ ❑ Comment: None Page# 4 Permit: N00070459 Owner -Facility: Inspection Date: 12/14/2016 Inspection Type: StarmountHigh School WWTP Compliance Evaluation Is the clarifier free of black and odorous wastewater? S ❑ Equalization Basins Yes No NA NE Is the basin aerated? N ❑ ❑ ❑ Is the basin free of bypass lines or structures to the natural environment? 0 ❑ ❑ ❑ Is the basin free of excessive grease? 0 ❑ ❑ ❑ Are all pumps present? ® ❑ ❑ ❑ Are all pumps operable? 0 ❑ ❑ ❑ Are float controls operable? N ❑ ❑ ❑ Are audible and visual alarms operable? E ❑ ❑ ❑ # Is basin size/volume adequate? N ❑ ❑ ❑ Comment: None Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? S ❑ ❑ ❑ Is the site free of excessive buildup of solids in center well of circular clarifier? ❑ ❑ ® ❑ Are weirs level? ■ ❑ ❑ ❑ Is the site free of weir blockage? N ❑ ❑ ❑ Is the site free of evidence of short-circuiting? 0 ❑ ❑ ❑ ❑ Is scum removal adequate? N ❑ ❑ ❑ Is the site free of excessive floating sludge? 0 ❑ ❑ ❑ Is the drive unit operational? ❑ ❑ E ❑ Is the return rate acceptable (low turbulence)? ® ❑ ❑ ❑ Is the overflow clear of excessive solids/pin floc? N ❑ ❑ ❑ Is the sludge blanket level acceptable? (Approximately %4 of the sidewall depth) ❑ ❑ ❑ E Comment: None Aeration Basins Yes No NA NE Mode of operation Ext. Air Type of aeration system Diffused Is the basin free of dead spots? 0 ❑ ❑ ❑ Are surface aerators and mixers operational? ❑ ❑ 0 ❑ Are the diffusers operational? . ❑ ❑ ❑ Is the foam the proper color for the treatment process? 0 ❑ ❑ ❑ Does the foam cover less than 25% of the basin's surface? ■ ❑ ❑ ❑ Is the DO level acceptable? ❑ ❑ ❑ 0 Page# � 5 Permit: NCO070459 Owner -Facility: Starmount High School WWTP Inspection Date: 12/14/2016 Inspection Type: Compliance Evaluation Aeration Basins Yes No NA NE Is the DO level acceptable?(1.0 to 3.0 mg/1) ❑ ❑ ❑ M Comment: None Disinfection - UV Yes No NA NE Are extra UV bulbs available on site? N ❑ ❑ ❑ Are UV bulbs clean? E ❑ ❑ ❑ Is UV intensity adequate? 0 ❑ ❑ ❑ Is transmittance at or above designed level? N ❑ ❑ ❑ Is there a backup system on site? 0 ❑ ❑ ❑ Is effluent clear and free of solids? N ❑ ❑ ❑ Comment: None Pumps -RAS -WAS Yes No NA NE Are pumps in place? M ❑ ❑ ❑ Are pumps operational? 0 ❑ ❑ ❑ Are there adequate spare parts and supplies on site? 0 ❑ ❑ ❑ Comment: None Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? M ❑ ❑ ❑ Are all other parameters(excluding field parameters) performed by a certified lab? N ❑ ❑ ❑ # Is the facility using a contract lab? N ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees ❑ ❑ ❑ E Celsius)? Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? ❑ ❑ ❑ Incubator (BOD) set to 20.0 degrees Celsius +/-1.0 degrees? ❑ ❑ ❑ 0 Comment: None Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ❑ ❑ E ❑ Is sample collected below all treatment units? ❑ ❑ ❑ Is proper volume collected? ❑ ❑ ❑ Is the tubing clean? ❑ ❑ 0 ❑ Page# 6 Permit: NCO070459 Owner -Facility: Starmount High School WWTP Inspection Date: 12/14/2016 Inspection Type: Compliance Evaluation Effluent Sampling Yes No NA NE # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees ❑ ❑ ❑ 0 Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type ❑ ❑ ❑ representative)? Comment: None Page# 7