Loading...
HomeMy WebLinkAboutNC0020931_Compliance Inspection 2015_20150428 FbENR North Carolina Department of Environment and Natural Resources Pat McCrory Donald R. van der Vaart Governor Secretary April 28, 2015 Town of Boonville Attn: Russell Hunter, IV, Mayor P.O. Box 326 RECEIVED/DENR/DWR Boonville, NC 27011-0326 SUBJECT: Compliance Evaluation Inspection MAY 5 2015 Boonville Wastewater Treatment Plant Water Quality NPDES Permit: NC0020931 Permitting Section Yadkin County Dear Mr. Hunter: Ron Boone of the Winston Salem Regional Office(WSRO)of the North Carolina Division of Water Resources (DWR or the Division) conducted a compliance evaluation inspection of the Boonville Wastewater Treatment Plant on April 14, 2015. The assistance and cooperation of Jeff Jones, Operator in Responsible Charge (ORC), was greatly appreciated. An inspection report is attached for your records and the inspection findings are summarized below. The Boonville Wastewater Treatment Plant is located at 456 Lon Avenue, at approximate coordinates 36.246177°, -80.707273°, in Boonville, Yadkin County, North Carolina. The Town of Boonville is authorized to operate this 0.2 million-gallon-per-day (MGD) wastewater treatment plant, which consists of a bar screen, splitter box, comminutor, aeration basins,secondary clarifiers, UV disinfection,digesters, sludge drying beds, and flow measurement, and discharge treated effluent from outfall 001 of said treatment works, which is located approximately 250 feet east of the treatment works at approximate coordinates 36.246536°, -80.706452°, into Tanyard Creek, which is currently classified as Class C waters and is located in the Yadkin Pee-Dee River Basin. SITE REVIEW Mr. Boone reviewed the entire plant with Mr. Jones. Everything was in good condition and well maintained. The effluent was clear and there was no foam at the discharge point into Tanyard Creek. The discrepancies Mr. Boone noted are as follows: 1. The plant does not have a field laboratory certification. A certification must be acquired for the plant to run dissolved oxygen, pH, and temperature analyses themselves. Please go to the following website to initiate this process: http://portal.ncdenr.orq/web/wq/lab/cert 2. Influent sampling is not flow proportional as required by the permit. There is no influent flow meter. The Town may wish to request exemption from this requirement from the Division. DOCUMENTATION REVIEW 450 West Hanes Mill Road,Suite#300,Winston-Salem,North Carolina 27105 Phone:336-776-98001 Internet:www.ncdenr.gov An Equal Opportunity 1 AKrmative Action Employer—Made in part by recycled paper • -+ , All documentation for the plant was reviewed, including operator visitation logs, operation and maintenance logs, laboratory bench and field sheets,discharge monitoring reports,chains of custody, and contract laboratory reports. No discrepancies were noted.All required records were present, readily available,and complete. There were no other discrepancies noted. Mr. Jones and his operators are doing a good job operating and maintaining the plant. Please keep up the excellent work in ensuring the plant is properly operated and maintained and meeting all the terms and conditions of the permit. Please strive to have the discrepancies mentioned above corrected within 45 days of receipt of this notice. Please remember that violations of the permit are subject to enforcement actions not to exceed $25,000 per day, per violation. If you have any questions regarding the inspection or this letter, please do not hesitate to contact Mr. Boone or me at 336-776-9800. Thank ybu for your cooperation in this matter. Sincerely, `v f W. Corey Basinger Regional Supervisor Water Quality Regional Operations Division of Water Resources Attachments: 1. BIMS Inspection Report CC: Central Files NPDES Unit WSRO/SWP Files Town of Boonville Attn:Jeff Jones, Operator in Responsible Charge P.O. Box 326 Boonville, NC 27011-0326 , 4 s. United States Environmental Protection Agency Form Approved. EPA Washington,D.C.20460 OMB No.2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A:National Data System Coding(i.e.,PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 Li 2 IS I 3 I NC0020931 111 12 I 15/04/14 117 181,.1 191 S 201 21111111 1111111111111111111111111 11111111111 r6 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ---- Reserved 671 I 701 LJ I 71 LI 72 I Lti J I 731 1 174 751 1 1 1 1 1 1 1 180 Section B:Facility Data t Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Date Permit Effective Date • POTW name and NPDES permit Number) 10:00AM 15/04/14 15/02/01 Boonville WWTP Exit Time/Date Permit Expiration Date 110 Carolina Ave 12:00PM 15/04/14 18/12/31 Boonville NC 27011 Name(s)of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data /// Jeffrey Eugene Jones/ORC/252-639-7544/ Name,Address of Responsible Official/Title/Phone and Fax Number Contacted Robert Gardner,P0 Box 326 Boonville NC 270110326//336-367-7941/3363674205 No Section C:Areas Evaluated During Inspection(Check only those areas evaluated) I* Permit up Flow Measurement • Operations&Maintenance • Records/Reports 41 Self-Monitoring Program a Sludge Handling Disposal • Facility Site Review li Effluent/Receiving Waters di Laboratory Section D:Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s)and Signature(s)of Inspector(s) Agency/Office/Phone and Fax Numbers Date Ron Boone WSRO WQ//336-776-9690/ i9c.....c.4 172-514.5.-- Signature_if Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date i / . ;K.k_ - EPA Form 3560-3(Rev 9-94)Previous editions are obsolete. Page# 1 _ d NPDES yr/mo/day Inspection Type 1 31 NC0020931 111 121 15/04/14 117 18 U Section D:Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) Please refer to the attached inspection summary letter. Page# 2 1 • + Permit: NC0020931 Owner-Facility: BoonvilleWWfP Inspection Date: 04/14/2015 Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new 0 0 • 0 application? Is the facility as described in the permit? • 0 0 0 #Are there any special conditions for the permit? 0 • 0 0 Is access to the plant site restricted to the general public? • 0 0 0 Is the inspector granted access to all areas for inspection? • 0 0 0 Comment: None Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? • 0 0 0 Is all required information readily available, complete and current? • 0 0 0 Are all records maintained for 3 years(lab. reg. required 5 years)? • 0 0 0 Are analytical results consistent with data reported on DMRs? • 0 0 0 Is the chain-of-custody complete? • 0 0 0 Dates,times and location of sampling • Name of individual performing the sampling • Results of analysis and calibration • Dates of analysis 111 Name of person performing analyses U Transported COCs • Are DMRs complete:do they include all permit parameters? • 0 0 0 Has the facility submitted its annual compliance report to users and DWQ? 0 0 • 0 (If the facility is=or>5 MGD permitted flow)Do they operate 24/7 with a certified operator 0 0 • 0 on each shift? Is the ORC visitation log available and current? • 0 0 0 Is the ORC certified at grade equal to or higher than the facility classification? • 0 0 0 Is the backup operator certified at one grade less or greater than the facility classification? • 0 0 0 Is a copy of the current NPDES permit available on site? • 0 0 0 Facility has copy of previous year's Annual Report on file for review? 0 0 • 0 Comment: None Laboratory Yes No NA NE Are field parameters performed by certified personnel or laboratory? 0 • 0 0 Are all other parameters(excluding field parameters)performed by a certified lab? • 0 0 0 Page# 3 Permit NC0020931 Owner-Facility: BoonvilleWWTP Inspection Date: 04/14/2015 Inspection Type: Compliance Evaluation Laboratory Yes No NA NE #Is the facility using a contract lab? • 0 0 0 #Is proper temperature set for sample storage(kept at less than or equal to 6.0 degrees 0 0 0 • Celsius)? Incubator(Fecal Coliform)set to 44.5 degrees Celsius+/-0.2 degrees? 0 0 0 • Incubator(BOD)set to 20.0 degrees Celsius+/-1.0 degrees? 0 0 0 • Comment: Facility not sampling at time of inspection. Influent Sampling Yes No NA NE #Is composite sampling flow proportional? 0 • 0 0 Is sample collected above side streams? • 0 0 0 Is proper volume collected? U 0 0 0 Is the tubing clean? • 0 0 0 #Is proper temperature set for sample storage(kept at less than or equal to 6.0 degrees 0 0 0 • Celsius)? Is sampling performed according to the permit? • 0 0 0 Comment: Facility not sampling at time of inspection. Effluent Sampling Yes No NA NE Is composite sampling flow proportional? • 0 0 0 Is sample collected below all treatment units? • 0 0 0 Is proper volume collected? • 0 0 0 Is the tubing clean? • 0 0 0 #Is proper temperature set for sample storage(kept at less than or equal to 6.0 degrees 0 0 0 • Celsius)? Is the facility sampling performed as required by the permit(frequency,sampling type • 0 0 0 representative)? Comment: Facility not sampling at time of inspection. Upstream/Downstream Sampling Yes No NA NE Is the facility sampling performed as required by the permit(frequency,sampling type, and • 0 0 0 sampling location)? Comment: None Bar Screens Yes No NA NE Type of bar screen Pa9e# 4 Permit NC0020931 Owner-Facility: Boonville VWVfP Inspection Date: 04/14/2015 Inspection Type: Compliance Evaluation Bar Screens Yes No NA NE a.Manual U b.Mechanical 0 Are the bars adequately screening debris? • 0 0 0 Is the screen free of excessive debris? • 0 0 0 Is disposal of screening in compliance? • 0 0 0 Is the unit in good condition? U 0 0 0 Comment: None Aeration Basins Yes No NA NE Mode of operation Ext.Air Type of aeration system Diffused Is the basin free of dead spots? • 0 0 0 Are surface aerators and mixers operational? 0 0 • 0 Are the diffusers operational? • 0 0 0 Is the foam the proper color for the treatment process? • 0 0 0 Does the foam cover less than 25%of the basin's surface? • 0 0 0 Is the DO level acceptable? 0 0 0 IN Is the DO level acceptable?(1.0 to 3.0 mg/I) 0 0 0 IN Comment: None Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? • 0 0 0 Is the site free of excessive buildup of solids in centerwell of circular clarifier? • 0 0 0 Are weirs level? • 0 0 0 Is the site free of weir blockage? • 0 0 0 Is the site free of evidence of short-circuiting? • 0 0 0 Is scum removal adequate? • 0 0 0 Is the site free of excessive floating sludge? • 0 0 0 Is the drive unit operational? • ❑ 0 0 Is the return rate acceptable(low turbulence)? • 0 0 0 Is the overflow clear of excessive solids/pin floc? • ❑ 0 0 Is the sludge blanket level acceptable?(Approximately 1/4 of the sidewall depth) 0 0 0 • Comment: None Page# 5 Permit NC0020931 Owner-Facility: Boonville wWrP e Inspection Date: 04/14/2015 Inspection Type: Compliance Evaluation Secondary Clarifier Yes No NA NE Pumps-RAS-WAS Yes No NA NE Are pumps in place? • 0 0 0 Are pumps operational? • 0 0 0 Are there adequate spare parts and supplies on site? • 0 0 0 • Comment: None Flow Measurement- Effluent Yes No NA NE #Is flow meter used for reporting? • 0 0 0 Is flow meter calibrated annually? • 0 0 0 Is the flow meter operational? • 0 0 0 (If units are separated)Does the chart recorder match the flow meter? • 0 0 0 Comment: None Disinfection- UV Yes No NA NE Are extra UV bulbs available on site? • 0 0 0 Are UV bulbs clean? • 0 0 0 Is UV intensity adequate? • 0 0 0 Is transmittance at or above designed level? • 0 0 0 Is there a backup system on site? • 0 0 0 Is effluent clear and free of solids? • 0 0 0 Comment: None Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? • 0 0 0 Are the receiving water free of foam other than trace amounts and other debris? • ❑ 0 0 If effluent (diffuser pipes are required) are they operating properly? 0 0 • 0 Comment: None Aerobic Digester Yes No NA NE Is the capacity adequate? • 0 0 0 Is the mixing adequate? U 0 0 0 Is the site free of excessive foaming in the tank? • 0 0 0 Page# 6 r e Permit NC0020931 Owner-Facility: Boonville VWVfP Inspection Date: 04/14/2015 Inspection Type: Compliance Evaluation Aerobic Digester Yes No NA NE #Is the odor acceptable? • 0 0 0 #Is tankage available for properly waste sludge? • 0 0 0 Comment: None Drying Beds Yes No NA NE Is there adequate drying bed space? • 0 0 0 Is the sludge distribution on drying beds appropriate? • 0 0 0 Are the drying beds free of vegetation? • 0 0 0 #Is the site free of dry sludge remaining in beds? 0 • 0 0 Is the site free of stockpiled sludge? 0 • 0 0 Is the filtrate from sludge drying beds returned to the front of the plant? • 0 0 0 #Is the sludge disposed of through county landfill? • 0 0 0 #Is the sludge land applied? 0 IN 0 0 (Vacuum filters)Is polymer mixing adequate? 0 0 • 0 Comment: None Operations& Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? • 0 0 0 Does the facility analyze process control parameters,for ex: MLSS, MCRT,Settleable • 0 0 0 Solids,pH, DO, Sludge Judge,and other that are applicable? Comment: None Standby Power Yes No NA NE Is automatically activated standby power available? 0 • 0 0 Is the generator tested by interrupting primary power source? 0 II 0 ❑ Is the generator tested under load? • 0 0 0 Was generator tested&operational during the inspection? 0 • 0 0 Do the generator(s)have adequate capacity to operate the entire wastewater site? • 0 0 0 Is there an emergency agreement with a fuel vendor for extended run on back-up power? 0 • 0 0 Is the generator fuel level monitored? • 0 0 0 Comment: None Page# 7