HomeMy WebLinkAboutNC0020931_Compliance Inspection 2015_20150428 FbENR
North Carolina Department of Environment and Natural Resources
Pat McCrory Donald R. van der Vaart
Governor Secretary
April 28, 2015
Town of Boonville
Attn: Russell Hunter, IV, Mayor
P.O. Box 326 RECEIVED/DENR/DWR
Boonville, NC 27011-0326
SUBJECT: Compliance Evaluation Inspection MAY 5 2015
Boonville Wastewater Treatment Plant Water Quality
NPDES Permit: NC0020931 Permitting Section
Yadkin County
Dear Mr. Hunter:
Ron Boone of the Winston Salem Regional Office(WSRO)of the North Carolina Division of Water Resources
(DWR or the Division) conducted a compliance evaluation inspection of the Boonville Wastewater Treatment Plant on
April 14, 2015. The assistance and cooperation of Jeff Jones, Operator in Responsible Charge (ORC), was greatly
appreciated. An inspection report is attached for your records and the inspection findings are summarized below.
The Boonville Wastewater Treatment Plant is located at 456 Lon Avenue, at approximate coordinates
36.246177°, -80.707273°, in Boonville, Yadkin County, North Carolina. The Town of Boonville is authorized to operate
this 0.2 million-gallon-per-day (MGD) wastewater treatment plant, which consists of a bar screen, splitter box,
comminutor, aeration basins,secondary clarifiers, UV disinfection,digesters, sludge drying beds, and flow measurement,
and discharge treated effluent from outfall 001 of said treatment works, which is located approximately 250 feet east of
the treatment works at approximate coordinates 36.246536°, -80.706452°, into Tanyard Creek, which is currently
classified as Class C waters and is located in the Yadkin Pee-Dee River Basin.
SITE REVIEW
Mr. Boone reviewed the entire plant with Mr. Jones. Everything was in good condition and well maintained.
The effluent was clear and there was no foam at the discharge point into Tanyard Creek. The discrepancies Mr. Boone
noted are as follows:
1. The plant does not have a field laboratory certification. A certification must be acquired for the plant to
run dissolved oxygen, pH, and temperature analyses themselves. Please go to the following website to
initiate this process:
http://portal.ncdenr.orq/web/wq/lab/cert
2. Influent sampling is not flow proportional as required by the permit. There is no influent flow meter. The
Town may wish to request exemption from this requirement from the Division.
DOCUMENTATION REVIEW
450 West Hanes Mill Road,Suite#300,Winston-Salem,North Carolina 27105
Phone:336-776-98001 Internet:www.ncdenr.gov
An Equal Opportunity 1 AKrmative Action Employer—Made in part by recycled paper
•
-+ ,
All documentation for the plant was reviewed, including operator visitation logs, operation and maintenance
logs, laboratory bench and field sheets,discharge monitoring reports,chains of custody, and contract laboratory reports.
No discrepancies were noted.All required records were present, readily available,and complete.
There were no other discrepancies noted. Mr. Jones and his operators are doing a good job operating and
maintaining the plant. Please keep up the excellent work in ensuring the plant is properly operated and maintained and
meeting all the terms and conditions of the permit.
Please strive to have the discrepancies mentioned above corrected within 45 days of receipt of this notice.
Please remember that violations of the permit are subject to enforcement actions not to exceed $25,000 per day, per
violation.
If you have any questions regarding the inspection or this letter, please do not hesitate to contact Mr. Boone
or me at 336-776-9800. Thank ybu for your cooperation in this matter.
Sincerely,
`v f
W. Corey Basinger
Regional Supervisor
Water Quality Regional Operations
Division of Water Resources
Attachments:
1. BIMS Inspection Report
CC:
Central Files
NPDES Unit
WSRO/SWP Files
Town of Boonville
Attn:Jeff Jones, Operator in Responsible Charge
P.O. Box 326
Boonville, NC 27011-0326
, 4 s.
United States Environmental Protection Agency Form Approved.
EPA Washington,D.C.20460 OMB No.2040-0057
Water Compliance Inspection Report Approval expires 8-31-98
Section A:National Data System Coding(i.e.,PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 Li 2 IS I 3 I NC0020931 111 12 I 15/04/14 117 181,.1 191 S 201
21111111 1111111111111111111111111 11111111111 r6
Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ---- Reserved
671 I 701 LJ I 71 LI 72 I Lti J I 731 1 174 751 1 1 1 1 1 1 1 180
Section B:Facility Data
t
Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Date Permit Effective Date
• POTW name and NPDES permit Number) 10:00AM 15/04/14 15/02/01
Boonville WWTP
Exit Time/Date Permit Expiration Date
110 Carolina Ave
12:00PM 15/04/14 18/12/31
Boonville NC 27011
Name(s)of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data
///
Jeffrey Eugene Jones/ORC/252-639-7544/
Name,Address of Responsible Official/Title/Phone and Fax Number
Contacted
Robert Gardner,P0 Box 326 Boonville NC 270110326//336-367-7941/3363674205
No
Section C:Areas Evaluated During Inspection(Check only those areas evaluated)
I* Permit up Flow Measurement • Operations&Maintenance • Records/Reports
41 Self-Monitoring Program a Sludge Handling Disposal • Facility Site Review li Effluent/Receiving Waters
di Laboratory
Section D:Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s)and Signature(s)of Inspector(s) Agency/Office/Phone and Fax Numbers Date
Ron Boone WSRO WQ//336-776-9690/
i9c.....c.4
172-514.5.--
Signature_if Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
i
/ . ;K.k_ -
EPA Form 3560-3(Rev 9-94)Previous editions are obsolete.
Page# 1
_ d
NPDES yr/mo/day Inspection Type 1
31 NC0020931 111 121 15/04/14 117 18 U
Section D:Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary)
Please refer to the attached inspection summary letter.
Page# 2
1
• + Permit: NC0020931 Owner-Facility: BoonvilleWWfP
Inspection Date: 04/14/2015 Inspection Type: Compliance Evaluation
Permit Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new 0 0 • 0
application?
Is the facility as described in the permit? • 0 0 0
#Are there any special conditions for the permit? 0 • 0 0
Is access to the plant site restricted to the general public? • 0 0 0
Is the inspector granted access to all areas for inspection? • 0 0 0
Comment: None
Record Keeping Yes No NA NE
Are records kept and maintained as required by the permit? • 0 0 0
Is all required information readily available, complete and current? • 0 0 0
Are all records maintained for 3 years(lab. reg. required 5 years)? • 0 0 0
Are analytical results consistent with data reported on DMRs? • 0 0 0
Is the chain-of-custody complete? • 0 0 0
Dates,times and location of sampling •
Name of individual performing the sampling •
Results of analysis and calibration •
Dates of analysis 111
Name of person performing analyses U
Transported COCs •
Are DMRs complete:do they include all permit parameters? • 0 0 0
Has the facility submitted its annual compliance report to users and DWQ? 0 0 • 0
(If the facility is=or>5 MGD permitted flow)Do they operate 24/7 with a certified operator 0 0 • 0
on each shift?
Is the ORC visitation log available and current? • 0 0 0
Is the ORC certified at grade equal to or higher than the facility classification? • 0 0 0
Is the backup operator certified at one grade less or greater than the facility classification? • 0 0 0
Is a copy of the current NPDES permit available on site? • 0 0 0
Facility has copy of previous year's Annual Report on file for review? 0 0 • 0
Comment: None
Laboratory Yes No NA NE
Are field parameters performed by certified personnel or laboratory? 0 • 0 0
Are all other parameters(excluding field parameters)performed by a certified lab? • 0 0 0
Page# 3
Permit NC0020931 Owner-Facility: BoonvilleWWTP
Inspection Date: 04/14/2015 Inspection Type: Compliance Evaluation
Laboratory Yes No NA NE
#Is the facility using a contract lab? • 0 0 0
#Is proper temperature set for sample storage(kept at less than or equal to 6.0 degrees 0 0 0 •
Celsius)?
Incubator(Fecal Coliform)set to 44.5 degrees Celsius+/-0.2 degrees? 0 0 0 •
Incubator(BOD)set to 20.0 degrees Celsius+/-1.0 degrees? 0 0 0 •
Comment: Facility not sampling at time of inspection.
Influent Sampling Yes No NA NE
#Is composite sampling flow proportional? 0 • 0 0
Is sample collected above side streams? • 0 0 0
Is proper volume collected? U 0 0 0
Is the tubing clean? • 0 0 0
#Is proper temperature set for sample storage(kept at less than or equal to 6.0 degrees 0 0 0 •
Celsius)?
Is sampling performed according to the permit? • 0 0 0
Comment: Facility not sampling at time of inspection.
Effluent Sampling Yes No NA NE
Is composite sampling flow proportional? • 0 0 0
Is sample collected below all treatment units? • 0 0 0
Is proper volume collected? • 0 0 0
Is the tubing clean? • 0 0 0
#Is proper temperature set for sample storage(kept at less than or equal to 6.0 degrees 0 0 0 •
Celsius)?
Is the facility sampling performed as required by the permit(frequency,sampling type • 0 0 0
representative)?
Comment: Facility not sampling at time of inspection.
Upstream/Downstream Sampling Yes No NA NE
Is the facility sampling performed as required by the permit(frequency,sampling type, and • 0 0 0
sampling location)?
Comment: None
Bar Screens Yes No NA NE
Type of bar screen
Pa9e# 4
Permit NC0020931 Owner-Facility: Boonville VWVfP
Inspection Date: 04/14/2015 Inspection Type: Compliance Evaluation
Bar Screens Yes No NA NE
a.Manual U
b.Mechanical 0
Are the bars adequately screening debris? • 0 0 0
Is the screen free of excessive debris? • 0 0 0
Is disposal of screening in compliance? • 0 0 0
Is the unit in good condition? U 0 0 0
Comment: None
Aeration Basins Yes No NA NE
Mode of operation Ext.Air
Type of aeration system Diffused
Is the basin free of dead spots? • 0 0 0
Are surface aerators and mixers operational? 0 0 • 0
Are the diffusers operational? • 0 0 0
Is the foam the proper color for the treatment process? • 0 0 0
Does the foam cover less than 25%of the basin's surface? • 0 0 0
Is the DO level acceptable? 0 0 0 IN
Is the DO level acceptable?(1.0 to 3.0 mg/I) 0 0 0 IN
Comment: None
Secondary Clarifier Yes No NA NE
Is the clarifier free of black and odorous wastewater? • 0 0 0
Is the site free of excessive buildup of solids in centerwell of circular clarifier? • 0 0 0
Are weirs level? • 0 0 0
Is the site free of weir blockage? • 0 0 0
Is the site free of evidence of short-circuiting? • 0 0 0
Is scum removal adequate? • 0 0 0
Is the site free of excessive floating sludge? • 0 0 0
Is the drive unit operational? • ❑ 0 0
Is the return rate acceptable(low turbulence)? • 0 0 0
Is the overflow clear of excessive solids/pin floc? • ❑ 0 0
Is the sludge blanket level acceptable?(Approximately 1/4 of the sidewall depth) 0 0 0 •
Comment: None
Page# 5
Permit NC0020931 Owner-Facility: Boonville wWrP e
Inspection Date: 04/14/2015 Inspection Type: Compliance Evaluation
Secondary Clarifier Yes No NA NE
Pumps-RAS-WAS Yes No NA NE
Are pumps in place? • 0 0 0
Are pumps operational? • 0 0 0
Are there adequate spare parts and supplies on site? • 0 0 0
•
Comment: None
Flow Measurement- Effluent Yes No NA NE
#Is flow meter used for reporting? • 0 0 0
Is flow meter calibrated annually? • 0 0 0
Is the flow meter operational? • 0 0 0
(If units are separated)Does the chart recorder match the flow meter? • 0 0 0
Comment: None
Disinfection- UV Yes No NA NE
Are extra UV bulbs available on site? • 0 0 0
Are UV bulbs clean? • 0 0 0
Is UV intensity adequate? • 0 0 0
Is transmittance at or above designed level? • 0 0 0
Is there a backup system on site? • 0 0 0
Is effluent clear and free of solids? • 0 0 0
Comment: None
Effluent Pipe Yes No NA NE
Is right of way to the outfall properly maintained? • 0 0 0
Are the receiving water free of foam other than trace amounts and other debris? • ❑ 0 0
If effluent (diffuser pipes are required) are they operating properly? 0 0 • 0
Comment: None
Aerobic Digester Yes No NA NE
Is the capacity adequate? • 0 0 0
Is the mixing adequate? U 0 0 0
Is the site free of excessive foaming in the tank? • 0 0 0
Page# 6
r e
Permit NC0020931 Owner-Facility: Boonville VWVfP
Inspection Date: 04/14/2015 Inspection Type: Compliance Evaluation
Aerobic Digester Yes No NA NE
#Is the odor acceptable? • 0 0 0
#Is tankage available for properly waste sludge? • 0 0 0
Comment: None
Drying Beds Yes No NA NE
Is there adequate drying bed space? • 0 0 0
Is the sludge distribution on drying beds appropriate? • 0 0 0
Are the drying beds free of vegetation? • 0 0 0
#Is the site free of dry sludge remaining in beds? 0 • 0 0
Is the site free of stockpiled sludge? 0 • 0 0
Is the filtrate from sludge drying beds returned to the front of the plant? • 0 0 0
#Is the sludge disposed of through county landfill? • 0 0 0
#Is the sludge land applied? 0 IN 0 0
(Vacuum filters)Is polymer mixing adequate? 0 0 • 0
Comment: None
Operations& Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? • 0 0 0
Does the facility analyze process control parameters,for ex: MLSS, MCRT,Settleable • 0 0 0
Solids,pH, DO, Sludge Judge,and other that are applicable?
Comment: None
Standby Power Yes No NA NE
Is automatically activated standby power available? 0 • 0 0
Is the generator tested by interrupting primary power source? 0 II 0 ❑
Is the generator tested under load? • 0 0 0
Was generator tested&operational during the inspection? 0 • 0 0
Do the generator(s)have adequate capacity to operate the entire wastewater site? • 0 0 0
Is there an emergency agreement with a fuel vendor for extended run on back-up power? 0 • 0 0
Is the generator fuel level monitored? • 0 0 0
Comment: None
Page# 7