HomeMy WebLinkAboutNC0072699_Renewal (Application)_20170125a
January 25, 2017
To Whom It May Concern:
RE: NPDES Permit No. NC0072699
RECEIVEDINCDEOIDWR
JAN 2 7 2017
vVater Quality
perrnitting Section
The Town of Beaufort is requesting renewal of the Pine street Water Facility
NPDES permit NC007699. There have been one changes since the issuance of the
last permit. Well 5 was added in April of 2013 to the Pine Street Water Facility.
This well has not changed the amount discharge from this facility.
Frank Sansone
Town of Beaufort
Water Systems ORC
(252) 728-2130 (office)
(252) 241-0651 (cell)
f.sansone@beaufortnc.org
L , T
NPDES PERMIT APPLICATION - SHORT FORM C - WTP
For discharges associated with water treatment plants
Mail the complete application to:
N. C. Department of Environment and Natural Resources
Division of Water Quality / NPDES Unit
1617 Mail Service Center, Raleigh, NC 27699-1617
NPDES Permit Number INCO072699
If you are completing this form in computer use the TAB key or the up - down arrows to move from one
field to the next. To check the boxes, click your mouse on top of the box. Otherwise, please print or type.
1. Contact Information:
Owner Name
Facility Name
Mailing Address
City
State / Zip Code
Telephone Number
Fax Number
e-mail Address
Town of Beaufort
Pine Street Water Facility
P.O. Box 390
Beaufort
North Carolina 285716
(252)728-2141
(252)728-3982
d. willis@beaufortnc.org
2. Location of facility producing discharge:
Check here if same as above ❑
Street Address or State Road
City
State / Zip Code
County
910 Pine Street
Beaufort
North Carolina 285715
Carteret
3. Operator Information:
Name of the firm, consultant or other entity that operates the facility. (Note that this is not referring to the
Operator in Responsible Charge or ORC)
Name Town of Beaufort
Mailing Address P.O. Box 390
City Beaufort
State / Zip Code North Carolina 28516
Telephone Number (252)728-2130
Fax Number (252) 728-3982
4. Ownership Status:
Federal ❑ State ❑ Private ❑ Public X❑
Page 1 of 4 ' Version 5/2012
NPDES PERMIT APPLICATION - SHORT FORM C - WTP
For discharges associated with water treatment plants
5. Type of treatment plant:
❑ Conventional (Includes coagulation, flocculation, and sedimentation, usually followed by
filtration and disinfection)
X❑ Ion Exchange (Sodium Cycle Cationic ion exchange)
❑ Green Sand Filter (No sodium recharge)
❑ Membrane Technology (RO, nanofiltration)
Check here if the treatment process also uses a water softener ❑
6. Description of source water(s) (i.e. groundwater, surface water)
Ground Water
7. Describe the treatment process(es) for the raw water:
Raw water from two wells goes to Culligan softeners with post feed of Chlorine (gas) and
Hydrofluosilicic Acid (23%)
8. Describe the wastewater and the treatment process(es) for wastewater generated by the
facility:
Water is de chlorinated with sodium Bisulflte ( 38/40%)
9. Number of separate discharge points: One 1
Outfall Identification number(s)
10. Frequency of discharge: Continuous ❑
If intermittent:
Days per week discharge occurs: Seven (7)
11. Plant design potable flowrate .60 MGD
Backwash or reject flow .010 MGD
Intermittent X❑
Duration: two ( 2) hours
12. Name of receiving stream(s) (Provide a map showing the exact location of each outfall, including
latitude and longitude):
Unnamed tributary of Town Creek in the White Oak River Basin
13. Please list all water treatment additives, including cleaning chemicals or disinfection
treatments, that have the potential to be discharged.
Page 2 of 4 Version 5/2012
NPDES PERMIT APPLICATION - SHORT FORM C - WTP
For discharges associated with water treatment plants
Alum / aluminum sulfate Yes No X
Iron sulfate / ferrous sulfate Yes No X
Fluoride Yes X No
Ammonia nitrogen / Chloramines Yes No X
Zinc -orthophosphate or sweetwater CP1236 Yes No X
List any other additives below:
Sodium Bi Sulfite
14. Is this facility located on Indian country? (check one)
Yes 0
No X❑
15. Additional Information:
Provide a schematic of flow through the facility, include flow volumes at all points in
the water treatment process. The plan should show the point[s] of addition for
chemicals and all discharges routed to an outfall [including stormwater].
Solids Handling Plan
16. NEW Applicants
Information needed in addition to items 1-15:
New applicants are highly encouraged to contact a permit coordinator with the
NCDENR Customer Service Center.
Was the Customer Service Center contacted? ❑ Yes ❑ No
Analyses of source water collected
Engineering Alternative Analysis
Discharges from Ion Exchange and Reverse Osmosis plants shall be evaluated using a
water quality model.
17. Applicant Certification
I certify that I am familiar with the information contained in the application and that to the
best of my knowledge and belief such information is true, complete, and accurate.
Charles Burgess Jr. Town Manager
Printed name of Person Signing Title
Signature of Applicant
Da
,2 5-//7
North Carolina General Statute 143-215.6 (b)(2) provides that: Any person who knowingly makes any false statement representation, or certification in any application,
record, report, plan, or other document files or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that
Article, or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21
Page 3 of 4 Version 5/2012
NPDES PERMIT APPLICATION - SHORT FORM C - WTP
For discharges associated with water treatment plants
imprisonment not to exceed sic months, or by both. (18 U.S.C. Section 1001 provides a punishment by a fine of not more than $25,000 or imprisonment not more than 5
years, or both, for a similar offense.)
Page 4 of 4 Version 5/2012
Quad: I32 NW, Beaufort, N.C.
Latitude: 34°43'04"
Longitude: 76°39'22"
Stream Class: SC
Subbasin:0 3-05-03
Receiving Stream: UT Town Creek
NCO072699
Town of Beaufort
Pine Street WTP
Facility
Location.�f:
North Carteret County
N
b q .4wYaO w
�' r,•5' 1 000 / off, a aaA1S
1 � 1 D S