Loading...
HomeMy WebLinkAboutNC0004944_NOV2016PC0398_2016081611511111 _ Vii, DAT 7 h 4 T — .-. ,_ -•'-:�-;+'—,"i-_rn,. -,�.-,_^,.- „-r.-,-gip, _ - -- - _,h^_ Psi m..,._ red _ i _�,_ _ _ _ __--_ _ - - _ _ _- _ F�-,"�_;f•„ _ ._,r -q -'a x`� •. ,.��,,;•- ':'-- -'., _.'t:p'-''J"';_ '-^ —_`' air .,,I— — - - - -,y - 'aY, _,�r•- - 'I'i�- - - - - _ _ _ !i _ _ qni ti., ::y:,v __ "•tip v'ti' ; �. . . - - - - - - -`fir=• - - _ _ r.; - _ t�.�"• ,jai=."i_ , -y', ,,, - „ •, "' „ __,_ w .,. '',, ,"`` - } '" F - Certified Mail # 7015 1520 0002 8386 7748 Return Receipt Requested August 11, 2016 `� �i`i nmwe��f��`t AUC, � � 2016 Donald Peterson, Owner Durafiber Technologies Inc. tiNat�r secs en 7401 Statesville Blvd. Permitting Salisbury, NC 28145 SUBJECT: NOTICE OF VIOLATION & INTENT TO ASSESS CIVIL PENALTY Tracking Number: NOV-2016-PC-0398 Permit No. NC0004944 DuraFiber Technologies Inc. Rowan County Dear Mr. Peterson: The ,North Carolina ,Division of Water Resources conducted an inspection ,of the DuraFiber Technologies Inc. on August 4, 2016. This -inspection was.conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NC0004944. A summary of the findings and comments noted during the inspection are provided in the enclosed copy of the inspection report., The Compliance Evaluation inspection was conducted by Division of Water Resources staff from the Mooresville Regional Office. The following violation(s) were noted during the inspection: Inspection Area r Description of Violation Operations, & Maintenance Effluent trough on secondary clarifier is filled with sludge and growing vegetation, vegetation also noted growing on weirs. Flow Measurement - Effluent Facility did not have annual calibration records for flow meter. Record Keeping Facility did not have sludge processing or disposal records. Laboratory Facility is performingBOD, Fecal Coliform and field parameters. During inspection it was noted that thermometers for storage refrigerator, BOD incubator, Fecal Coliform incubator, and DO meter have not been -checked against. NIST traceable thermometer. Last temperature check was dated 2013. State of North Carolina I Environmental Quality I Water Resources 610 East Center Avenue, Suite 301, Mooresville, NC 28115 704-663-1699 I Inspection Area Description of Violation �l Secondary Clarifier RAS pump not operating at time of inspection. Secondary clarifier we denitrifying with solids flowing over weir. Accumulation of sludge in effluent trough with vegetation (grass) growing in effluent trough. In addition, the issues below must also be addressed: Compliance Issue(s):. RAS pumps not in operation, accumulation of sludge and vegetation in effluent trough on secondary clarifier - Please be advised that in accordance with your NPDES Permit No. 0004944, Part II, Section C., 2. Proper Operation and Maintenance, The Permittee shall at all times provide the operation and maintenance resources necessary to operate the existing facilities at optimum efficiency. Flow meter did not have annual calibration records '- In accordance with NPDES Permit No. 0004944, Part II, Section D., 3. Flow Measurements, Flow measurements devices shall be accurately calibrated at a minimum of once per year and maintained to ensure that the accuracy of the measurements is consistent with the accepted capability of that type of device. Facility did not have sludge processing or sludge disposal records — In accordance with NPDES Permit No. 0004944, Part II, Section C., 6. Removed Substances; The Permittee shall comply with all existing Federal regulations governing the disposal of sewage sludge (40 CFR Part 503). The Permittee shall notify the Permit Issuing Authority of any significant change in its sludge, use or disposal practices. In accordance with 40 CFR Part 503 Standards for the Use and Disposal of Sewage Sludge records shall be kept and maintained for a period of 5 years. Thermometers'' in Laboratory have not'been checked against NIST traceable therniometer.'Laboratory is certified under Laboratory Certification:flumber 200 In accordance with 40 CFR Part 136r(SeeNC WW/GW Laboratory Certification web site) Temperature measuring devices must be' calibrated against a ,National Institute of Standards & Technology (NIST) traceable -thermometer every 12 `months and any corrections must be documented. Agreement between the thermometers must be within 0.5° C. A Notice of Violation/Intent to Issue Civil Penalty is being issued for the noted violation of North Carolina General Statute (G.S.) 143-215.,1 and the facility's NPDES Permit. Pursuant to G.S. 143-215.6A, a-civilpenalty of not more than twenty-five thousand dollars ($25,000.00) may be assessed against•any person who violates or fails to act in accordance with the terms,..conditions,_or requirements of any permit issued pursuant,to G.S. 143-215.1. If you wish to provide -additional information regarding the noted violation, request technical assistance, or discuss overall compliance please respond,in writing within ten (10) business days after receipt of this Notice. A review of your response will be considered along -with: any information provided on the submitted Discharge Monitoring Report(s): You will•then be notified of any civil -penalties that may be assessed regarding the violations. If no response is received in this Office within the 10 -day period, a civil penalty assessment may be prepared. r.` v Remedial actions should have already been taken to correct this problem and prevent further occurrences in the future. The Division of Water Resources may pursue enforcement action for this and any additional violations of State law. If the violations are of a continuing nature, not related to operation and/or maintenance problems, and you anticipate remedial construction activities, then you may wish to consider applying for_ a Special Order by Consent. Reminder: Pursuant to Permit Condition 6 in Section E. the Permittee is required to verbally notify the Regional Office as soon as possible, not to exceed 24 hours, from first knowledge of any non-compliance at the facility including limit violations, bypasses of, or failure of a treatment.unit. A written report may be required within 5 days if directed by Division staff. Prior notice should be given for anticipated or potential problems due to planned maintenance activities, taking units off-line, etc. Additionally and if you have not already done so, you may wish to consider registering to use the Division's new e -DMR system for the completion and electronic submittal of monthly Discharge Monitoring Reports (DMRs). For more information, please visit the eDMR Website at the following address: http://portal.ncdenr.org/web/wq/admin/bog/ipu/edmr. If you should have any questions, please do not hesitate to contact Roberto Scheller with the Water Quality Regional- Operations Section in the Mooresville Regional Office at 704-663-1699. Sincerely, W. Corey Basinger, Regional Supervisor Water Quality. Regional Operations Section Mooresville Regional Office Division of Water Resources, NCDEQ ATTACHMENTS Cc: Beth Swanson, Laboratory Certification Branch, Email: beth.swanson@ncdenr.gov WQS Mooresville Regional Office - Enforcement File NPDES Compliance/Enforcement Unit - Enforcement File State of North Carolina I Environmental Quality I Water Resources 610 East Center Avenue, Suite 301, Mooresville, NC 28115 704-663-1699 United states Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 2 15 3 I NC0004944 111 1,2 1 16/08/04 17 18 i ,, i 19 Li I 201 I 2111 1 1 1 1 1 1 1 1 1 1 1. I I I I I I I I I I I I I I I I I I I I 'I I I I I I I I I I -166 I Reserved Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA --Reserved- I I 72 I N 73 I I 174 751 1 1 1 I I I 180 67 70 71 J 671 I_I l� I I 1 Section B: FacilityData. Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit•Effective Date POTW name and NPDES permit Number) 10:OOAM 16/08/04 10/10/01 Dural Technologies Inc. 7401 Statesville Blvd Exit Time/Date permit Expiration Date Salisbury NC 28147 11:56AM 16/08/04 14/03/31 Name(s) of Onsite Representative(s)rritles(s)/Phone and Fax Number(s) Other Facility Data ; William Keith McDonald/ORC/336-472-2023/ Name, Address of Responsible OfriciaUritie/Phone and Fax Number Contacted _ Donald Peterson,7401 Statesville Blvd Salisbury NC 28147/Plant No Manager/704-636-6000/ Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenance Records/Reports Sludge Handling Disposal Facility Site Review Effluent/Receiving Waters Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signatures) of Inspectors) Agency/Office/Phone and Fax Numbers Date Roberto Scheller MRO WQ//252-946-6481/ ' 1 Signature of Management Q A Reviewer Agen ifiice/Phone and Fax Numbers Date W. Corey Basinger MRO WQ//704-235-2194/ EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Ifill I111111111IOI�,pC-aQ . avJt2 •ice I t Aut-5 -zw w Page# I Permit NC0004944 Owner -Facility:, DuraFiberTechnologies Inc. Inspection Date: 08/04/2016 Inspection Type: Compliance Evaluation Operations & Maintenance - Yes No NA'NE Does the facility analyze process control parameters, for ex: MLSS,-MCRT, Settleable N' ❑ ❑ ❑ Solids, pH, DO; Sludge Judge, and other that are applicable? Comment: Effluent trough on secondary clarifier was filled with sludge and growing vegetation. Vegetation also noted growing on weirs. RAS pump not operating resulting in clarifier denitrifying. Bar Screens Yes No NA NE Type of bar screen . ❑ a.Manual ❑ b.Mechanical a.Manual Is the grit free of excessive organic matter? ❑ , ❑ ❑ Is the grit free of excessive odor? ❑ ❑ ❑ b.Mechanical ❑ ❑ ❑ ❑ Are the bars adequately screening debris? ❑ . ❑ ❑ Is the screen free of excessive debris? ❑ . ❑ ❑ Is disposal of screening in compliance? M ❑ - ❑ ❑ Is the unit in good condition? M. El 1-1 ❑ ❑ Comment: Grit Removal Yes No NA NE Type of grit removal . ❑ a.Manual ❑ b.Mechanical Is the'basin free of bypass lines or structures to the natural environment? Is the grit free of excessive organic matter? ❑ , ❑ ❑ Is the grit free of excessive odor? ❑ ❑ ❑ # Is disposal of grit in compliance? ❑ ❑ ❑ Comment: Equalization Basins Yes No NA NE' Is the'basin aerated? . ❑ ❑ , M ❑ Is the'basin free of bypass lines or structures to the natural environment? 0 '❑ '.❑ ❑ Is the basin free of excessive grease? M ❑ ❑ ❑ Are all pumps present? [1-11 ❑ Are all pumps operable? ❑ ❑ , ❑ Are float controls operable? ❑ ❑ M ❑ Are audible and visual alarms operable? 11 '❑ -❑ ❑ # Is basin size/volume adequate? 0 ❑ ❑ ❑ Page# 4 Permit NC0004944 Inspection Date: 08/04/2016 Equalization Basins Owner - Facility Durafter Technologies Inc. Inspection Type: Compliance Evaluation Comment: EQ basin consist of 2 covered above ground tanks. Aeration Basins Mode of operation Type of aeration system Is the basin free of dead spots? Are surface aerators and mixers operational? Are the diffusers operational? Is the foam the proper color for the treatment process? Does the foam cover less than 25% of the basin's surface? Is the DO level acceptable? Is the DO level acceptable?(1.0 to 3.0 mg/I) Yes No NA NE_ Yes No NA NE Ext. Air Is the clarifier free of black and odorous wastewater? ❑ Surface ❑ ❑ ■ ❑- ❑ ❑ 10 ❑ ❑ ❑ ❑ ❑ ■ ❑ X ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ .N Comment: MLSS thin with color of slightly turbid water. RAS pump on secondary clarifier not operational resulting in treatment unit having no acculamation of bio -mass. Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? ❑ E ❑ ❑ Is the site free of excessive buildup of�solids in center well of circular clarifier? 0 ❑ ❑ ❑ Are weirs level? 0 ❑ ❑ ❑ Is the site free of weir blockage? ❑ N ❑ ❑ Is the site free of evidence of short-circuiting? ❑ ❑ ❑ ❑ _ Is scum removal adequate? ❑ ❑ ❑ Is the site free of excessive floating sludge? ❑ ❑ ❑ Is the•drive unit operational? ❑ ❑ ❑ 11. Is the return rate acceptable (low turbulence)? ❑" 0 ❑ ❑ Is the overflow clear of excessive solids/pin floc? ❑ 0 ❑ ❑ Is the sludge blanket'level acceptable? (Approximately % of the sidewall depth) ❑ N ❑ ❑ Comment: RAS pump not operating at time of inspection. Secondary clarifier was denitrifying with solids flowing over weir. Accumulation of sludge -in effluent trough with y6getation'&bgs) growing in effluent trough. Pumps-RASMAS Yes No. NA NE Are pumps in place? ❑ ❑" ❑ Are pumps operational? ❑ I N ❑ ❑ Are there adequate spare parts and supplies on site? ❑ E ❑ ❑ Page# 5 1 Permit N00004944 _ Owner -Facility: DuraFiberTechnologies Inc. Inspection Date: 08/04/2016 Inspection Type: Compliance Evaluation Pumps -RAS -WAS Yes No NA NE Comment: RAS pumps not operational. Aerobic Digester Is the capacity adequate? Is the mixing adequate? Is the site free of excessive foaming in the tank? # Is the odor acceptable? # Is tankage available for properly waste sludge? Comment: One of the two areation basins is being used as aerobic digester. Lagoons Type of lagoons? # Number of lagoons in operation at time of visit? Are lagoons operated in? # Is a re -circulation line present? Is lagoon free of excessive floating materials? # Are baffles between ponds or effluent baffles adjustable? � Are dike slopes clear of woody vegetation? Are weeds controlled around the edge of the lagoon? Are dikes free of seepage? Are dikes free of erosion? Are dikes free of burrowing animals? # Has the sludge blanket in the lagoon (s) been measured periodically in multiple locations? # If excessive algae is present, has barley straw been used to help control the growth? Is the lagoon surface free of weeds? Is the lagoon free of short circuiting? Comment: Lagoons follow treatment units and are used as polishing ponds. ' Laboratory Are field parameters performed by certified personnel or laboratory? Are all other parameters(excluding field parameters) performed by a certified lab? # Is the facility using a contract lab? Yes No NA NE Yes No NA NE ❑ ❑ ❑ 3 ❑ ❑ M ❑ ❑ ❑ M ❑ ❑ ❑ 'M ❑ ❑ • ❑ Yes No NA NE Aerated 1 3 ❑ ❑ Series M ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ❑ ❑ M ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ ■ ❑ ❑ ❑ M ❑ ❑ ❑ ❑ ❑ ❑ ■ ❑ .❑ ❑ ❑ ❑ ■ ❑ M ❑ ❑ ❑ ■ ❑ ❑ ❑ Yes No NA NE ❑ ❑ ❑ M ❑ ❑ ❑ Page# 6 Permit: NC0004944 Owner -Facility: Durafter Technologies Inc. Inspection Date: 08/04/2016 Inspection Type: Compliance Evaluation Yes No NA NE # Is flow meter used for reporting? 0 Laboratory Yes No NA NE # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees ❑ 0 ❑ ❑ Celsius)? Is the flow meter operational? 0 ❑ ❑ Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/_ 0.2 degrees? ❑ 0 ❑ ❑ Incubator (BOD) set to 20.0 degrees Celsius +/-1.0 degrees? ❑ 0 ❑ ❑ Comment: Facility is performing BOD, Fecal Coliform and field prameters. During inspection it was noted that thermometers for storage refrigerator, BOD incubator, Fecal Coliform incubator, and DO meter have not been checked aginst NIST traceable thermometer. Last temperature check was dated 2013. Flow Measurement - Influent Yes No NA NE # Is flow meter used for reporting? 0 ❑ ❑ ❑ Is flow meter calibrated annually? ❑ M ❑ ❑ Is the flow meter operational? 0 ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? 0 ❑ ❑ ❑ Comment: Facility did not have annual calibration records for flow meter. Page# . 7