HomeMy WebLinkAboutNC0084441_NOV2016PC0641_20161216A
Certified Mail # 7015 1520 0003 5463 1476
Return Receipt Requested
December 08, 2016
Michael A. Cornblum
Conleys Creek Limited Partnership
1112 Conley's Creek Rd
Whittier, NC 28789
SUBJECT: NOTICE OF VIOLATION
Tracking Number: NOV-2016-PC-0641
(Follow up to 2015 Inspection)
Permit No. NCO084441
Smoky Mountain Country Club
Swain County
Dear Permittee:
ailJd)u,lra.:.d��tl
DEC 15 2016
VVater Quality
Permitting Section
The North Carolina Division of Water Resources conducted an inspection of the Smoky Mountain Country Club on
November -10, 2016: This inspection was conducted to verify that the facility is operating in compliance with the
conditions and limitations specified in NPDES WW Permit No. NC0084441. A summary of the findings and
comments noted during the inspection are provided in the enclosed copy of the inspection report.
The Compliance Evaluation inspection was conducted by Division of Water Resources staff from the Asheville
Regional Office. The following violation(s) were noted during the inspection:
Inspection Area Description of Violation
Flow Measurement - Effluent The chart recorder did not appear to match the meter readings.
Operations & Maintenance The WWTP splitter box is rusted and should be painted.
Leaf debris is still an issue particularly at the effluent weir.
The tubing for the composite sampler needs to be changed. .
Safety grates are needed to cover the pump area of the EQ basin and the aeration basin (2
grates needed).
Safety railing should be installed around both clarifiers.
State of North Carolina I Environmental Quality I Water Resources
2090 U.S. 70 Highway, Swannanoa, NC 28778
828-296-4500
Remedial actions should have already been taken to correct this problem and prevent further occurrences in the
future. The Division'of Water Resources may pursue enforcement action for this and any additional violations of
State law.
To prevent further action, please respond in writing to this office within 30 days upon your receipt of this Notice
of Violation regarding your plans or measures to be taken to address the indicated violations and other identified
issues, if applicable.
If you should have any questions, please do not hesitate to contact Beverly Price with the Water Quality
Regional Operations Section in the Asheville Regional Office at 828-296-4500.
Sincerely,
Landon iDavidson,P:G. Tonal Supervisor
Water Quality Regional Operations Section,
Asheville Regional Office
Division of Water Resources, NCDEQ
ATTACHMENTS
Cc: WQS Asheville Regional Office -'Enforcement File
NPDES Compliance/Enforcement Unit - Enforcement File
G:\WR\WQ\Swain\Wastewater\Minors\Smoky Mtn Country Club 84441\Word Docs\84441 CEI 16 follow up NOV-2016-PC-0641.rtf
United States Environmental Protection Agency
Form Approved.
EPA Washington; D C. 20460
OMB No. 2040-0057
Water Compliance Inspection Report
Approval expires 6-31-98
Section A: National Data System Coding (Le., PCS)
Transaction Code NPDES yr/mo/day Inspection Type
Inspector Fac Type
1 IN I 2 15 I 3 I N90084441. I11 12 16/11/10 17 181 1
19 1 � I 201 L-
21.1111 1 1 1 1 1 111 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I I I
I I I I � I_I I f6
Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA --------Reserved----=----
67 j 70 [j 71 I I 72 I �, I 73 I I 174 751 I I I I L I I80
I L�
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW,.also include
Entry Time/Date
Permit Effective Date
POTW name and NPDES permit Number)
10:00AM 16/11/10 -
13/01/01
Smoky Mountain Country Club
1112 Conleys Creek Rd -
Exit Time/Date
Permit Expiration Date
Whittier NC 28789
11:15AM 16/11/10
17/10/31
Name(s) of Onsite Representative(s)/Titles(s)/Phoneand Fax Number(s)
Other Facility Data
Mark Fredrick Teague/ORC/828-293-9396/
Name, Address of Responsible OfficiaVTitle/Phone and Fax Number
Contacted
Michael A Comblum,1112 Conley's Creek Rd Whittier NC 26789/General
Partner/828-497-2772/8284971111 Yes
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
® Flow Measurement Operations & Maintenance Effluent/Receiving Waters
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers
Datep,
Beverly Price *� ARO WQ//828-296-4500/
Signature Manage Q A Reviewer Agency/Office/Phone and Fax Numbers
Date
' `
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page#
NPDES yr/mo/day Inspection Type - (Cont.) 1
31 Ncoo84441 I11 12 16/11/10 17 18 ICI
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists'as necessary)
The inspection was conducted by Beverly Price and Mika[ Willmer of the Asheville Regional Office.
Mark Teague and Michael Cornblum assisted with the inspection. This inspection was a follow up to
the 2015 inspection.
The Asheville Regional Office (ARO) appreciates the response to 2015 Notice of Violation (NOV).'
While some issues were completely resolved, others still need attention.
The following issues still need.to be resolved:
Operations & Maintenance:
1. The exterior of the WWTP was painted; however, the splitter box is also rusted. Any part of the
WWTP that has significant rust should be painted.
2. The tubing for the composite sampler needs to be changed.
3. Safety grates were placed over a portion of the EQ basin; however, additional grates are needed.
Grates are needed to cover the pump area.of the EQ basin and the aeration basin (2 grates).
4. Leaf debris was removed as required but remains an issue particularly at the effluent weir.
Flow Measurement:
Repairs/adjustments were made to the effluent meter; however, the chart recorder still does not
appear to match the readings from the flow meter.
Operation & Maintenance: Not noted during the 2015 inspection.
Safety railing should be -installed at the clarifiers.
Page# 2
Permit: NCO084441 Owner -Facility: Smoky Mountain Country Club '
Inspection Date: 11/10/2016 Inspection Type: Compliance Evaluation
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? ❑ ❑ ❑
Does the facility analyze process control -parameters, for ex: MLSS, WRT, Settleable ■ ❑ ❑ ❑
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment: The exterior of the WWTP was painted as required in the previous NOV: however. the
splitter box is also rusted. Any part of the WWTP that has significant rust should be painted.
Leaf debris was removed as required in the previous NOV: however, at the time of the
follow up inspection, leaf debris was still an issue particularly•at the effluent weir.
The tubing for the composite sampler needs to be changed.
Safety grates were replaced over a portion of the EQ basin as required by the previous
NOV; however, additional grates -'are needed. Grates are also needed to'cover the pump
area of the. EQ basin and the aeration basin (2 prates needed).
Safety railing should be installed around both clarifiers..
Flow Measurement - Effluent
# Is flow meter used for reporting?
Is flow meter calibrated annually?
Yes No NA NE
■ ❑ ❑ ❑
Is the flow meter operational? 0 ❑ ❑ ❑
(If units are separated) Does the chart recorder match the flow meter? ❑ ❑ ❑
Comment: Jim Queen made repairs/adjustments to the flow meter during December 2015 & January
and make repairs
2016; however, at the time of the inspection the chart recorder did not appear
to match the
Effluent Pipe
Yes No NA NE
meter readings.
0
❑
❑
❑
Standby Power -
Yes No NA NE •
Is'automatically activated standby power available?
N
❑
❑
❑
Is the generator tested by interrupting primary power source?
E
❑
❑
❑
Is the generator tested under load?
❑
❑
❑
N
Was generator tested & operational during the inspection?
❑
0
E1.0
Do the generator(s) have adequate capacity to operate the entire wastewater site?
E
❑
❑
❑
Is there an emergency agreement with a fuel vendor for extended run on back-up power?
❑
❑
❑
0
Is the generator fuel level monitored?
E
❑
❑
0
Comment: , The transfer switch was not working. A breaker has been purchased and the Dermittee has
contracted with an electrician to meet with the power company
and make repairs
Effluent Pipe
Yes No NA NE
Is right of way to the outfall properly maintained?
0
❑
❑
❑
Are the receiving water free of foam other than trace amountsand other debris?
N
❑
❑
❑
If effluent (diffuser pipes are required) are they operating properly?
❑
❑
0
❑
Page# 3
ponnu wunmw*w Owner—Facility: Smoky Mountain Country Club
Inspection Date: 11x0/2016 Inspection Type: Compliance Evaluation
Effluent PipeYes No NA NE
---------^—' '
`
Com:munt `