HomeMy WebLinkAbout20000783 Ver 5_Site Plans_20170117 (2)TRADITIONS PHASE 2D 447 ROYAL MiLL AVE. V GRA pP oP Rc� R E JUNIPER AVE GNv o � o� c� X98 REVM ENGINEER DISCLAIMER EXECUTION OF THIS CONSTRUCTION PLAT BY THE REVIEW ENGINEER FOR THE TOWN OF WAKE FOREST IN NO WAY LIMITS THE RESPONSIBILITY OF THE OWNER AND ENGINEER OF RECORD WITH REGARD TO COMPLIANCE WITH ALL FEDERAL, STATE, AND LOCAL STANDARDS AND/OR CONDITIONS. 0111IM CERTIFICATE OWNER HEREBY CERTIFIES AND AGREES TO TAKE SUCH ACTION AS MAY BE REQUIRED BY THE TOWN OF WAKE FOREST TO CORRECT ANY ERRORS. OMISSIONS OR NON— COMPLIANCE WITH TOWN STANDARDS AND/OR CONDITIONS DESCRIBED IN THIS CONSTRUCTION PLAT. INCLUDING RE— SUBMISSION OR RE—EXECUTION OF THIS CONSTRUCTION PLAT WITH THE APPROPRIATE CORRECTIONS AND/OR REVISIONS. Owner Date ATTENTION CONTRACTORS The Construction Contractor responsible for the extension of water, sewer, and/or reuse, as approved in these plans, is responsible for contacting the Public Utilities Department at (21,2) 996_45N at least twenty four hours prior to beginning any of their construction. Failure to notify both City Departments in advance of beginning construction, will result in the issuance of monetary fines, and require reinstallation of any water or sewer facilities not inspected as a result of this notification failure. Failure to call for Inspection, Install a Downstream Plug, have Permitted Plans on the Jobsite, or any other Violation of City of Raleigh Standards will result in a Fine and Possible Exclusion from future work in the City of Raleigh. Iz Z U O Jp LL_ 0OLo ry 0 W Q 1 Z U) U Qa p I O Ld Z O t= I.—O V Z U W t—QW Z � w O Y O � d I I' ,W i' r r � • i 1 1 • • ' ` 1 , r ,1 '� , r ,. .alA •• !• i OV OF r r, • 1 • i 1 • r ', 1 611 `i• • !r r f r • , r s DEV ELOPER: JPM SOUTH DIEM PMENT, LLC_ 72108 FALLS OIrm NEUSE1n%T"%,SUYJPE • RALEMia NORTH . (919) 518-9210 Public Water Distribution / Extension System The city of Raleigh consents to the connection and extension of the City's public water system as shown on this plan. The material and Construction methods used for this project shall conform to the standards and specifications of the Clty's Public Utilities Handbook. Cityy of Raleigh Public Utilities Department Permit #,',,11/3 Authorization to Construct? Date s i111b Public Sewer Collection / Extension System The city of Raleigh consents to the connection and extension of the City's public sewer system as shown on this plan. The material and Construction methods used for this project shall conform to the standards and specifications of the City's Public Utilities Handbook. City of Raleigh S'— 44 `1 -2 , Public Utilities Department Permit # Authorization to Construct Z&4 Ll "" Date !V I i f 1. (P ALL CONSTRUCTION SHALL BE iN ACCORDANCE WITH TOW( DF WAKE FOREST, CITY OF RALEIGH & NCDOT (WHERE APPLICABLE) STANDARDS, SPECIFICATIONS, AND DETAILS. HORIZONTAL DATUM: NAD83 VERTICAL DATUM: NGVD29 Know what's below. 0111 before you dig. ALL PUBLIC FACILITIES, INCLUDING UTILITIES, SIDEWALKS, AND HANDICAP RAMPS ARE TO BE CONSTRUCTED ON ALL STREETS AS SPECIFIED BY TOWN STANDARDS. THESE FACILITIES HAVE BEEN APPROVED BY THE TOWN OF WAKE FOREST AND SHALL BE SO INSTALLED UNLESS A CHANGE IS APPROVED BY THE TOWN OF WAKE FOREST. THESE PLANS HAVE BEEN APPROVED FOR CONSTRUCTION BY THE TOWN OF WAKE FOREST Date Date Date Date Date Date 9/ Date I I 1 l City of Raleigh Public Utilities Department Date CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811 ". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. D-1 SITE DATA D-2 SnE DETAILS PHASE NUMBER: 2D STORM DRAINAGE DETAILS PHASE ACREAGE: 19.84 AC. D-7 TOTAL NUMBER OF SINGLE FAMILY LOTS CREATED: 50 DETAILS D-9 OPEN SPACE CREATED: 4.33 AC. EC -2 LINEAR FEET OF PUBLIC STREETS: 2,576 LF. LINEAR FEET OF PUBLIC WATER LINE: 2,819 LF. SW1-A LINEAR FEET OF PUBLIC SANITARY SEWER: 2,076 LF. SW1-C LINEAR FEET OF PUBLIC STORM DRAINAGE: 2,628 LF. SW2-B ZONING: GR10 SW2-C LEVEL SPREADER ! DETAILS LAND USE: SINGLE FAMILY RESIDENTIAL PIN: 1851356014 PRINCIPLE BUILDING SETBACKS: FRONT: 20ft STREET SIDE: 20ft SIDE: 8ft REAR: 25ft TRADITIONS PHASE 2D 447 ROYAL MiLL AVE. V GRA pP oP Rc� R E JUNIPER AVE GNv o � o� c� X98 REVM ENGINEER DISCLAIMER EXECUTION OF THIS CONSTRUCTION PLAT BY THE REVIEW ENGINEER FOR THE TOWN OF WAKE FOREST IN NO WAY LIMITS THE RESPONSIBILITY OF THE OWNER AND ENGINEER OF RECORD WITH REGARD TO COMPLIANCE WITH ALL FEDERAL, STATE, AND LOCAL STANDARDS AND/OR CONDITIONS. 0111IM CERTIFICATE OWNER HEREBY CERTIFIES AND AGREES TO TAKE SUCH ACTION AS MAY BE REQUIRED BY THE TOWN OF WAKE FOREST TO CORRECT ANY ERRORS. OMISSIONS OR NON— COMPLIANCE WITH TOWN STANDARDS AND/OR CONDITIONS DESCRIBED IN THIS CONSTRUCTION PLAT. INCLUDING RE— SUBMISSION OR RE—EXECUTION OF THIS CONSTRUCTION PLAT WITH THE APPROPRIATE CORRECTIONS AND/OR REVISIONS. Owner Date ATTENTION CONTRACTORS The Construction Contractor responsible for the extension of water, sewer, and/or reuse, as approved in these plans, is responsible for contacting the Public Utilities Department at (21,2) 996_45N at least twenty four hours prior to beginning any of their construction. Failure to notify both City Departments in advance of beginning construction, will result in the issuance of monetary fines, and require reinstallation of any water or sewer facilities not inspected as a result of this notification failure. Failure to call for Inspection, Install a Downstream Plug, have Permitted Plans on the Jobsite, or any other Violation of City of Raleigh Standards will result in a Fine and Possible Exclusion from future work in the City of Raleigh. Iz Z U O Jp LL_ 0OLo ry 0 W Q 1 Z U) U Qa p I O Ld Z O t= I.—O V Z U W t—QW Z � w O Y O � d I I' ,W i' r r � • i 1 1 • • ' ` 1 , r ,1 '� , r ,. .alA •• !• i OV OF r r, • 1 • i 1 • r ', 1 611 `i• • !r r f r • , r s DEV ELOPER: JPM SOUTH DIEM PMENT, LLC_ 72108 FALLS OIrm NEUSE1n%T"%,SUYJPE • RALEMia NORTH . (919) 518-9210 Public Water Distribution / Extension System The city of Raleigh consents to the connection and extension of the City's public water system as shown on this plan. The material and Construction methods used for this project shall conform to the standards and specifications of the Clty's Public Utilities Handbook. Cityy of Raleigh Public Utilities Department Permit #,',,11/3 Authorization to Construct? Date s i111b Public Sewer Collection / Extension System The city of Raleigh consents to the connection and extension of the City's public sewer system as shown on this plan. The material and Construction methods used for this project shall conform to the standards and specifications of the City's Public Utilities Handbook. City of Raleigh S'— 44 `1 -2 , Public Utilities Department Permit # Authorization to Construct Z&4 Ll "" Date !V I i f 1. (P ALL CONSTRUCTION SHALL BE iN ACCORDANCE WITH TOW( DF WAKE FOREST, CITY OF RALEIGH & NCDOT (WHERE APPLICABLE) STANDARDS, SPECIFICATIONS, AND DETAILS. HORIZONTAL DATUM: NAD83 VERTICAL DATUM: NGVD29 Know what's below. 0111 before you dig. ALL PUBLIC FACILITIES, INCLUDING UTILITIES, SIDEWALKS, AND HANDICAP RAMPS ARE TO BE CONSTRUCTED ON ALL STREETS AS SPECIFIED BY TOWN STANDARDS. THESE FACILITIES HAVE BEEN APPROVED BY THE TOWN OF WAKE FOREST AND SHALL BE SO INSTALLED UNLESS A CHANGE IS APPROVED BY THE TOWN OF WAKE FOREST. THESE PLANS HAVE BEEN APPROVED FOR CONSTRUCTION BY THE TOWN OF WAKE FOREST Date Date Date Date Date Date 9/ Date I I 1 l City of Raleigh Public Utilities Department Date CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811 ". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. D-1 DETAILS D-2 SnE DETAILS PAVEIMENr MARKING & SIGNAGE DETAILS D-4 STORM DRAINAGE DETAILS STORMD-3 DRAINAGE DETAILS ! DETAILS D-7 DETAILS ! DETAILS D-9 . ' DETAILS EROSION CONTROL STAGE EC -2 EROSION CONTROL PLAN STAGE 2 EROSION CONTROL DETAILS EROSION CONTROL DETAILS EROSION CONTROL i 1 SW1-A LEVEL SPREADERi DETAILS i LEVEL SPREADERDETAILS SW1-C r! . !, DETAILS LEVEL SPREADER SW2-A LEVEL SPREADER DETAILS SW2-B LEVEL SPREADER 2D-2 DETAILS SW2-C LEVEL SPREADER ! DETAILS SAL�� 24680 - ,L'•. !bG I NO -X tigN G.��oo CONSTRUCTION NOTE: PRIOR TO ANY FIELD CHANGES TO SIGNED CONSTRUCTION DRAWINGS, APPROVAL MUST BE OBTAINED FROM THE TOWN OF WAKE FOREST OR APPROPRIATE AGENCY. NO SUBSURFACE UTILITY SURVEY (SUE) HAS BEEN PERFORMED FOR THE PREPARATION OF THESE PLANS. ADDITIONAL UNDERGROUND UTILITIES MAY BE IN THE AREA. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR TO CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. t 2905 Meridlan Parkway Durham, North Carolina 27713 License No.: C-0293 (800) 733-5646 ■ McAdamsCoxom Contact: Jon Moore, PE moore@mcadamsco.com FINAL DRAWING — RELEASED FOR CONSTRUCTION X GENERAL NOTES 1. THIS IS A SURVEY OF AN EXISTING PARCEL(S) OF LAND. THIS IS AN EXISTING CONDITIONS PLAN.. 2. BEARINGS FOR THIS SURVEY ARE BASED ON NC GRID NAD 83. 3. ALL DISTANCES ARE HORIZONTAL GROUND DISTANCES. 4. ZONING: C.0 GR10. 5. AREA BY COORDINATE GEOMETRY. 6. FLOOD NOTE: THIS PROPERTY IS NOT LOCATED iN A SPECIAL FLOOD HAZARD ZONE. IT IS LOCATED IN ZONE "X" AS DEFINED BY F.E.M.A F.I.R.M COMMUNITY PANEL #3720184100J DATED MAY 2, 2006 & #372018510OK DATED APRiL 16, 2013. 7. REFERENCES: DB 10228, PG. 1762; BM 1996, PG. 676 OF THE WAKE COUNTY REGISTRY. PIN: 1 851 35601 4 8. UTILITY STATEMENT THE UNDERGROUND UTILITIES SHOWN HAVE BEEN LOCATED FROM FIELD SURVEY INFORMATION AND EXISTING DRAWINGS. THE SURVEYOR MAKES NO GUARANTEE THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED ALTHOUGH HE DOES CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM INFORMATION AVAILABLE. THE SURVEYOR HAS NOT PHYSICALLY LOCATED THE UNDERGROUND UTILITIES. 9. THIS SURVEY PERFORMED AND MAP PREPARED WITHOUT BENEFIT OF A TITLE REPORT. THIS SURVEY SUBJECT TO ANY FACTS AND EASEMENTS WHiCH MAY BE DISCLOSED BY A FULL AND ACCURATE TITLE SEARCH. 10. NO GRID MONUMENTS FOUND WITHIN 2000' OF SITE. °J TOP=344.87' TOP=342.33 INV IN=339.82 15"RCP INV iN=337. 3' 15"RCP iNV IN=339.12' 32"RCP INV IN=335. ' 32"RCP TOP= 2,3g' INV OUT=339.0T 32"RCP INV OUT=335 68' 32"RCP Y� INV OU L-33}5/5 ' 15"RCP °J / \\� , 41 ROYAL ANLL AVENUE as as as os as // / // / p // //// �� �\� � `�'`�� \ \\ t ` t 90' PROPOSED R/W Aj '10 }\\ - 89'05 TOP=342.19' 6-4iNV OUT=338.29' 1'5"RCP -,I V'R14, / XMMMV �- i �--- y \ EXISTING / i i ( �Q PUBLLO-- 1 I I I I I ( ( I / ��U G� F \\\\�\\\ \\\\r / ---- .�, /� / i \\� \\\\\\ \\ \ l \ \ \ ` / f / 1 i SSMH \ SANITARY tMER ESMT ( i I I I (� I 1 { 1 / o /% y'�/ \X\\ \\� \\\\\� i - J \) I I / o ? )\\\ \ B`h<1. 2009 PG. 172 I I I I I I I \ i I / \ � \ \�\ \�\\\\\ // /l f///1// //// \� \ \ \\ \' \ // /f 1 f ( I f ) \ \ \ \ \ �\ \ \ �\ RIM= 329.59 / \ \ ( ` IN(N)= 323.94 15 -SAN \�\\\\/ \ \\ \ \ \ \ \ / / // f/ //jl \ =x/332,. 4 1 >1 \ \ \\ \ / l j///h/ ///�// // //- \ \\\ \ \ `\ \ / / / / / / / / 1 1 1 / l \ \ ,AN = 326. i$ } }�� \\. ,OUT= 323.84 15"SAN 0<1 OUT 3�6.611 f h$4 \ \\\ \\ // \\\ SPE DIM TAT E€, / � (o / / / I \ i ► ! t iNV 1N-349 48' FVC° \ \ \ \ _ i } \ \� \ \ 1 1 1 ' 1 \ o\ \ \\ \\� /60 \ V RUTS 49.59, 8" VC-eyz\ \ \ \ \ ( \ \ \\= I \\iso\ \ \ \ \ 46 �\ \ \R \\ \\\ \ \ \\C'6\'•�\�`ScS\ ` \ \ \ \\ \ \\ \�\� T\ YR \\ \\\ 50TYPE\ Cg CebgC \ /� //�I� ,�+•��f/ / /�/ / f I •\ \ \ \ \�\ \ \ \ \ \ S V�F D'E\� I 0bN9ENT LLr✓: \mss \\ \\�� \( > �, \ �\\tea \\ \\ \\ \ \ \\\ \ \ \ \ \ \\ \ \D IGO 4,� FT.\ 2 \s\ \ \\ / \ \ \Ho`R\ONo\ \� OP=347.11' INV IN=341.34' 8"PVC s \ \ \ \ \ \ \ \\ INV OUT=341.22' 8"PVC Q& \R�r`\SOIL\TYPE\\� \\ ,/ ///��`',//�f / /f//� //// ////l / �• l CC�2\ / SSMH j RIM= 325.78 / IN(N) 320.03 15 -SAN OUT= 319.88 15"SAN 1 i \ 1 \\ \�.� �� `� /' _ �'�� t , 1 \ \ \\ \\ \\ \ - \ \ \ \ \ \ - .- ////iii%/--,-�//�j // / // / / // p• ;- -� --- •-. �- ,- �s''--_-_ _. ~ �0�`- -345-- ._...._.. -- .�- -_ `_ _` � \\ \\ i \ � \' 1 \ {} _\\\ \ \\ \ \ \ \ \ \ v) � t } ' (�' � / � �// i i� ����Q� / TOP=345.33' =S !&Os�� / i I oGI J j INV IN=338.73' 8"PVC 331 6g' --rte _ ~ \ 1 , 1 1 1 1 11 \ \ \ \ \ " / l I i f / l s INV OUT -338.63' 8"PVC RIM=H 322.5 1 IN(N)= 316 41 15"SAN OUT= 315 65 15"SAN ---/// ////� // LEGEND TOP=347.11' .----/ t \ EXISTING IRON PIPE INV IN=328.59' 8"PVC �6, - J 1 \ 1 t / \ - - - - - -f / \ ® IRON PIPE SET INV OUT=328.49' 8"PVC \ \ 1 \\�-----_/ / / // / / t oG A CALCULATED POINT BORE HOLE V \� QS SANITARY SEWER MANHOLE SANITARY SEWER CLEANOUT \\ \ \ \\\ \ \\ \\\\ \ (i' /325_ %/�/ l �l� I WATER VALVE WATER METER \ �CyC FiRE HYDRANT TELEPHONE PEDESTAL TQ TELEPHONE MANHOLE IjN n ELECTRIC BOX LIGHT POLE Cob POWER POLE �� CURB INLET �c)rn !� (D) STORM DRAINAGE MANHOLE CURVE TABLE E3YARD INLET CURVE RADIUS ARC LENGTH DELTA ANGLE CHORD BEARING CHORD LENGTH TANGENT Cl 645.00' 506.97' 45°02'05' S 66°34'39' E 494.02' 267.40' \ \ / / / / / / / / STORM DRAIN PIPE C2 455.00' 231.05' 29005'41' N 74°32'51' W 228.57' 118.07' \� \\ \ / /! / / / OU OVERHEAD UTILITY LINES W WATER UNE 36' 8"PVC 1 `.26'8"PV \\ \ \\ f � / // ��"" � 1�.�� (9 SS SANITARY SEWER LINE s \ b \ \ 11 I i i/ 1 j /'� T TELEPHONE LINE �- \ JI I 0 j/ H 1 G GAS LINE pz \sr \ y / \ I / RIM= 3 .61 UE UNDERGROUND ELECTRIC l l 1 j l / iN(N)= 14.11 15""S T UNDER R N TE PHON OUT= 14.01 157 A j/' U G OU D LE E ��� i . -X X- FENCE LINE f � GRAPHIC SCALE SSMH ! a' bF 60 0 30 60 120 RIM= 7.76 j 0.2% ANNUAL \ IN(N - 310.77 51 AN 1 inch = 60 ft. CHANCE FLOOD \ / ON A IN 1N= 311. AN HAZARD,� e o T� 310.6 AN FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION 3gQTEE TREE OR OTHER VEGETATION TO BE REMOVED UNDERGROUND UTILITY DEMOLITION NOTES: 1. ALL VISIBLE UTILITIES ARE SHOWN AT APPROXIMATE LOCATIONS. ACTUAL LOCATIONS AND DEPTH TO BE CONFIRMED BY CONTRACTOR IN THE FIELD PRIOR TO BEGINNING OF CONSTRUCTION. 2. CONTRACTOR SHALL CALL "NC811" (811 OR 1-800-632-4949) AT A LEAST 3 FULL BUSINESS DAYS PRIOR TO CONSTRUCTION TO HAVE� TO BE REMOVED EXISTING UTILITIES LOCATED. REPORT ANY DISTURBANCES TO THE ENGINEER IMMEDIATELY. AREA TO BE REMOVED (SIDEWALK, CURB AND GUTTER, 3. ALL DEMOLITION MATERIAL SHALL BE REMOVED FROM THE SITE AND / f AGM " . STRUCTURES, ASPHALT, CONCRETE DISPOSED OF IN A PROPER LOCATION AND METHOD BY THE PAVING, ETC.) CONTRACTOR AS DESIGNATED BY THE OWNER. / /\�� �' ""-y+/--- f Ny 4. A COPY of THE DEMOLITION NOTIFICATION FROM THE NC HEALTH NOTE: SEE PLAN FOR DETAILED DEMOLITION PROCEDURES, HAZARD CONTROL UNIT AND AN ASBESTOS INSPECTION REPORT � , / •-� ^� — - — — — SEQUENCING AND SPECIFICATIONS. FROM NC ACCREDITED ASBESTOS INSPECTOR MUST ACCOMPANY THE / — = =� `� -�� = . Y DEMOLITION PERMIT WHICH MUST BE OBTAINED FROM THE TOWN OF -LD—LD—LIMITS OF DISTURBANCE WAKE FOREST PRIOR TO THE START OF DEMOLITION.'` r \ \ > l Al 0 Yl<AR � 1 ^^A^ FL OD PLAIN. \c \1 ,.�` \` I`. V, TREE save (TYP.) 4- / / / / / 25 STREET YARb BUF ER \ \ EXISTING TREE TO 4�1 � BE REMOVED (TYP.) W / / 20' TOWN OF WAKE I% <" FOREST GREENWAY I hA ` t — — — — — EASEMENT no�A no ��' P, ��AU �\ �� EX. CURB & GUTTER AND ASPHALT TO BE REMOVED TO / ) �I ��% TIE TO EX. CURB & GUTTER A \ — / / % I I e AND EX. WATERLINE / \ I LIMITS/ OF � � v = /_ _ — — — _ DIS RBANCE J / /s 1 SAWCUT, REMOVED, AND REPLACE ASPHALT IN THIS , �-� ` ��� / / / ( f ( { .) o AREA TO TIE To EX. �\ r�L� ��, WATERLINE / I ` t— -- - - - -- i / I � -,-�\ ,a... g,-/-�D xz�•_,-/��'��7�� w — � / / � / � � \ � I I � �- _ . — � � / ,, / � � � I II II I II II I I I ° � 1 j �, `� EX. 20' SANITARY / / / / \ I I EXISTING TREE TO BE / i I ( I " SEWER EASEMENT a A VA % — I �'`". (B.M. 2009, Pc. 172) � — — — _ _— — — A V ''� / I 1 I { / / I 1 I 4 / I I I REMOVED (TYP.) BUF ERREEf YARD LDI LD 368 'A V I APPROXIMATELY 90 LF — — I / OF EX. CURB & GUTTERS \ \\��\� / f I / // / / XIST�NG ITY OF RALEI H 310' I ��" I I I / TO BE REMOVED / �A\3�� V < 1 / / / / / / — — — — ANIT{� RY SEWER EA�SEM NT ( ( - I I I / vsaw \ l i 1 / — _—IG;� / I� // / / 1 1 M1998 17r31�1z0 ( s I \ I EXISTING POWER LINE TO BE RELOCATED CONTRACTOR TO COORDINATE WITH UTILITY I I I I EXISTING POWER POLE/ \vim—� �� ! / — OWNER) I I L o I TO BE REMOVED / ���A�A yy��\ y J i !!! EXISTING POWER POLE TO BE REMOVED I I I EXISTING GRAVEL DRIVE TO BE REMOVED I / /• _ — _ EXISTING PbWER IPOII TO BE f " _ - -- i , OVED ox L, ---._ t _ _ m.. :....f , / EXISTING 10o POWER EASEMENT . —// ;�//, f///.:, I I \ \ \ l -�- \ ` I \BE ABANDONED — I / //j jr f/ 'irk, I I I \ \ { (NO REFERENCE FOUND) / / `" — _�%(��/%i%'`'�'�` 1 EXIS NG 1R\E LINE \ — EXISTING TREE TO BE \ V \ A \ V A REMOVED (TYP.) — �� "� ��� �► "'�� - __ j \ \ I �/ ` t EXISTING 100' r r POWER EASEMENT (NO REFERENCE FOUND) � SAVE (TYP.) THESE PLANS HAVE BEEN APPROVED FOR CONSTRUCTION BY THE TOWN OF WAKE FOREST �r---- 5 431,1111 En ee ing epartment 77Z- r Date /' Public W rks Department Date 8' t Er sin & Sediment Control Date Fi Prevent' n Date F Access' ity Date Pl Hing Depar { ent Date lo Ur ForfAtry, Date W IA City of Raleigh Public Utilities Department Date ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH TO OF WAKE FOREST, CITY OF RALEIGH & NCDOT (WHERE APPLICABLE) STANDARDS, SPECIFICATIONS, AND DETAILS. A HORIZONTAL DATUM: NAD83 I VERTICAL DATUM: NGVD29 GRAPHIC SCALE 50 0 25 50 100 II 1 inch = 50 ft. v ou C, o U tt ca � It+j O / X �. 7 t TRADI S (VARIABL 1 ,s r" LIC F1���� I i l: 4 1 r 1, .., l , / t t I r ,1 i I r, i DRAWING — RELEASED FOR CONSTRUCTION M �N CO . MV U � N w � U U O Z ■ 0 �g o -8 eq 8 00 VJ A A �N - L 24680 C)9 NG G. 10 1O co W QG' aA a� Z LO z r- OWCD gz C) Ha a a 0 �o A a I- t�1 V qA' 4 v p 1 Q �w0z w O W A O PROJECT NO. JPM-15010 FILENAME: JPM15010—DM1 DESIGNED BY: N D W DRAWN BY: DLP SCALE: 1 " = 50' DATE: 04-04-2016 SHEET N0. C-2 last MCADAMS U z 0 0 E 0 a. N M 01 N <V 6 I J, RIP M 0- :3 U rn c 3 v 0 0 U 2 co C 0 i 7 O 0to X N 0 10' 1.0' MULTI - PATI 13.5' 12.5' /2"/F' 1/4"/FT I 1/2"/FT 90' R/W VARIES (3.007. MAX) SITE PLAN NOTES 1. RIGHT-OF-WAY SHALL BE CLEARED AND GRUBBED WITHIN 50' OF ALL MINOR RESIDENTIAL, RESIDENTIAL, AND RESIDENTIAL COLLECTOR INTERSECTIONS. THE FULL LENGTH OF THE RIGHT-OF-WAY SHALL BE CLEARED AND GRADED ALONG ALL MAJOR, MINOR, & SENSITIVE AREA THOROUGHFARES. 2. WITHIN THE AREA DEFINED SIGHT TRIANGLES SHOWN ON THESE PLANS, THERE SHALL BE NO SIGHT OBSTRUCTING OR PARTLY OBSTRUCTING WALL, FENCE, SIGN, FOLIAGE BERMS, OR PARKED VEHICLES BETWEEN THE HEIGHTS OF 24 INCHES AND 8 FEET ABOVE THE CURB LINE ELEVATION OR THE NEAREST TRAVEL WAY IF NO CURB LINE EXISTS. 3. ALL CONSTRUCTION SHALL CONFORM TO THE LATEST TOWN OF WAKE FOREST AND/OR NCDOT STANDARDS AND SPECIFICATIONS AS APPLICABLE. 4. ALL DIMENSIONS SHOWN ON SITE PLAN ARE MEASURED TO BACK OF CURB UNLESS OTHERWISE NOTED. 5. CONTRACTOR SHALL MAINTAIN AN "AS -BUILT" SET OF DRAWINGS TO RECORD THE EXACT LOCATION OF ALL PIPING PRIOR TO CONCEALMENT. DRAWINGS SHALL BE GIVEN TO THE ENGINEER UPON COMPLETION OF THE PROJECT WITH A COPY OF THE TRANSMITTAL LETTER TO THE OWNER. 6. EXISTING IMPROVEMENTS DAMAGED DURING CONSTRUCTION SHALL BE REPLACED/RESTORED TO THEIR ORIGINAL CONDITION AND TO THE SATISFACTION OF THE OWNER, BY THE CONTRACTOR RESPONSIBLE FOR THE DAMAGE. 7. THE CONTRACTOR SHALL NOTE THAT THE DRAWINGS MAY NOT SHOW EVERY OFFSET, TRANSITION, FITTING, ETC. THAT MAY BE REQUIRED. THE CONTRACTOR SHALL INSTALL SUCH STANDARD APPURTENANCES AS REQUIRED TO CLOSELY FOLLOW THE GRADES AND ALIGNMENTS DEPICTED ON THE PLANS. 8. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. 9. CONTRACTOR IS RESPONSIBLE FOR COORDINATING CONSTRUCTION ACTIVITIES WITH THE APPROPRIATE UTILITY COMPANIES FOR ANY REQUIRED RELOCATIONS (I.E. POWER POLES, TELEPHONE PEDESTALS, WATER METERS, ETC.). 10. PRIOR TO BEGINNING CONSTRUCTION, THE GENERAL CONTRACTOR SHALL SCHEDULE AND ATTEND A PRECONSTRUCTION CONFERENCE WITH THE TOWN OF WAKE FOREST, A REPRESENTATIVE OF THE OWNER, THE GRADING COMPANY, THE EROSION CONTROL INSTALLER, AND A REPRESENTATIVE FOR THE ENGINEER OF RECORD. 11. ALL DIMENSIONS AND GRADES SHOWN ON THE PLANS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ENGINEER IF ANY DISCREPANCIES EXIST PRIOR TO PROCEEDING WITH CONSTRUCTION, FOR NECESSARY PLAN OR GRADE CHANGES. NO EXTRA COMPENSATION SHALL BE PAID TO CONTRACTOR FOR ANY WORK DONE DUE TO DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THESE PLANS IF SUCH NOTIFICATION HAS NOT BEEN GIVEN. 12. ACCESSIBLE RAMPS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE TOWN OF WAKE FOREST DETAILS. 13. ALL SIDEWALKS THAT CONNECT TO THE PUBLIC RIGHT-OF-WAY MUST BE ACCESSIBLE TO PERSONS WHO ARE BLIND, HAVE LOW VISION AND PEOPLE WITH MOBILITY DISABILITIES. PEDESTRIAN EXISTING ROUTES AND ALTERNATE PEDESTRIAN ROUTES DURING CONSTRUCTION WILL BE REQUIRED TO BE COMPLIANT WITH THE PUBLIC RIGHTS OF WAY ACCESSIBILITY GUIDELINES (PROWAG), 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN AND THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD). 14. TYPICAL PAVEMENT SECTION DETAILS ARE SHOWN WITHIN THIS SET AND INTENDED TO BE A MINIMUM PAVEMENT SECTION REQUIREMENT. THE CURRENT GEOTECHNICAL REPORT SHALL OVER -RIDE ALL TYPICAL PAVEMENT SEC11ONS SHOWN, IF THE GEOTECHNICAL ENGINEER DEEMS A HEAVIER SECTION IS REQUIRED. 15. EQUIPMENT AND PRODUCTS OTHER THAN THOSE SPECIFIED MAY BE USED PROVIDED APPROVAL HAS BEEN OBTAINED FROM THE OWNER IN WRITING PRIOR TO ORDERING OR INSTALLATION. THE CONTRACTOR SHALL WAIVE ANY CLAIM FOR ADDITIONAL COST RELATED TO SUBSTITUTION OF ALTERNATE EQUIPMENT. 16. IF UNFORESEEN CONDITIONS DEVELOP DURING CONSTRUCTION, REFER TO THE LATEST VERSION OF THE WAKE FOREST "MANUAL OF SPECIFICATIONS, STANDARDS AND DESIGN (MSSD) AND CONTACT ENGINEERING STAFF FOR FURTHER GUIDANCE. 17. ALL SIGNAGE ASSOCIATED WITH THE PUBLIC STREET SYSTEM SHALL ADHERE TO MUTCD STANDARDS AND SPECIFICATIONS. 18. PRIOR TO STARTING ANY CONSTRUCTION OF IMPROVEMENTS WITHIN ANY CITY OR NCDOT STREET OR HIGHWAY RIGHT-OF-WAY, THE FOLLOWING PROCEDURES SHALL BE UNDERTAKEN: CITY RIGHT-OF-WAY: CONTACT TOWN OF WAKE FOREST TRAFFIC ENGINEERING DEPARTMENT (919-435-9510) FOR INFORMATION ON DETOURS, OPEN CUTTING OF STREETS OR FOR ANY CONSTRUCTION WITHIN THE RIGHT-OF-WAY. NCDOT RIGHT-OF-WAY: CONTACT MCADAMS COMPANY PROJECT ENGINEERS (919-361-5000) AND OBTAIN ALL PERMITS AND ENCROACHMENTS (KEEP COPIES ON CONSTRUCTION SITE), ALSO CONTACT NCDOT DISTRICT OFFICE (919-733-3213) 24 HOURS IN ADVANCE PRIOR TO PLACING CURB AND GUTTER AND TOWN OF WAKE FOREST FOR SIDEWALKS AND RAMPS WITHIN NCDOT R/W. 19. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ESTABLISHING AND MAINTAINING ALL CONTROL POINTS AND BENCH MARKS NECESSARY. 20. STREET LIGHTING WILL BE INSTALLED IN ACCORDANCE WITH THE TOWN OF WAKE FOREST UNIFIED DEVELOPMENT ORDINANCE - CHAPTER 10.3.7. LIGHTING PLANS SHALL BE BY OTHERS. 21. OPEN SPACE TO BE MAINTAINED BY THE HOMEOWNERS ASSOCIATION. 22. LANDSCAPE, IRRIGATION AND SITE LIGHTING DESIGN TO BE PROVIDED BY OTHERS AND SHALL BE SUBMITTED UNDER SEPARATE COVER. 23. ALL HOUSING DESIGN INFORMATION SHALL BE SUBMITTED TO THE TOWN OF WAKE FOREST IN CONJUNCTION WITH BUILDING PERMIT PROCESS. 24. LOCATION OF FUTURE GREENWAY TRAIL TO BE SUBMITTED UNDER SEPARATE COVER FOR REVIEW/APPROVAL. 25. EXISTING VEGETATION AND NATURAL AREAS SHALL BE PROTECTED TO THE GREATEST EXTENT POSSIBLE AND THAT MINIMUM CLEARING OF LAND SHALL BE UNDERTAKEN DURING DEVELOPMENT. 12.5'1 13.5' 1 +,i ji -ri j ic-c- 1 1.0' 1 /2"/FT I 1 /4„/F.1. I- 2.5'1 /2„/ -- 30" STANDARD -- CURB AND GUTTER 30" STANDARD CURB AND GUTTER TYPICAL SECTION - 90' PUBLIC R/W, 41' B -B EX. ROYAL MILL AVENUE N.T.S. 1.0' 15' SIDEWALKI 6.5' 12.5' /2" 5' CONCRETE SIDEWALK 1/4"/F7_ 4 �F I 1/21,/F7 50' R/W 10' LANE 1 10' LANE 1/4"/FT I 1/4"/FF 2.5' 1 6.5' 15' SIDEWALKI 1.0' 1 /2 /F7r ( 1/4"/FT /4„/F /2" '*- 5' CONCRETE 30" VALLEY CURB- ` 30" VALLEY CURB SIDEWALK AND GUTTER PAVEMENT SECTION AND GUTTER 8" ABC, 2" S9.56 TYPICAL SECTION - 50' PUBLIC R/W, 25' B -B MEADOW GROVE DRIVE, GOLDFINCH NEST COURT, SPARROWHAWK LANE, HYDRANGEA FIELD COURT N.T.S. 60' R/W 1.0' 15' SIDEWALKI 6.5' 1 2.5' 1 15' LANE /2" 5' CONCRETE SIDEWALK 11 /� I 1/2"/Fr 1 /4"/FT 15' LANE 12.5'1 6.5' 15' SIDEWALKI 1.0' 1 /4"/FT 1/2"/FT /2/FT I 1 /4„/FT /2>, 30" VALLEY CURB-/ ASIDEWALK RETE AND GUTTER 30" VALLEY CURB PAVEMENT SECTION AND GUTTER 8" ABC, 2" S9.513 TYPICAL SECTION - 60' PUBLIC R/W, 35' B -B TRADITIONS RIDGE ROAD N.T.S. N 7 0 iJ PAVEMENT SECTION NOTE PAVEMENT SECTIONS SHOWN ARE TOWN OF WAKE FOREST MINIMUM STANDARDS. CONTRACTOR IS TO VERIFY PAVEMENT SECTIONS WITH GEOTECHNICAL REPORT. IF PAVEMENT SECTION IN THE GEOTECHNICAL REPORT DIFFERS FROM THE TOWN OF WAKE FOREST STANDARDS, THE CONTRACTOR IS TO USE THE GREATER OF THE TWO. GRADING NOTES 1. ALL DIMENSIONS AND GRADES SHOWN ON THE PLANS SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ENGINEER IF ANY DISCREPANCIES EXIST PRIOR TO PROCEEDING WITH CONSTRUCTION, FOR NECESSARY PLAN OR GRADE CHANGES. NO EXTRA COMPENSATION SHALL BE PAID TO THE CONTRACTOR FOR ANY WORK DONE DUE TO DIMENSIONS OR GRADES SHOWN INCORRECTLY ON THESE PLANS IF SUCH NOTIFICATION HAS NOT BEEN GIVEN. 2. OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS FOR EXCAVATIONS; FINAL RULE 29CFR PART 1926, SUBPART "P" APPLIES TO ALL EXCAVATIONS EXCEEDING FIVE (5) FEET IN DEPTH. EXCAVATION EXCEEDING TWENTY (20) FEET IN DEPTH REQUIRES THE DESIGN OF A TRENCH SAFETY SYSTEM BY A REGISTERED PROFESSIONAL ENGINEER, PROVIDED BY CONTRACTOR RESPONSIBLE FOR EXCAVATION. 3. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE CITY OF RALEIGH AND/OR NCDOT STANDARDS AND SPECIFICATIONS AS APPLICABLE. 4. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. 5. PRIOR TO BEGINNING CONSTRUCTION, THE GENERAL CONTRACTOR SHALL SCHEDULE AND ATTEND A PRE -CONSTRUCTION CONFERENCE WITH THE CITY OF RALEIGH STORMWATER AND EROSION CONTROL DEPARTMENT, THE ENGINEER AND A REPRESENTATIVE OF THE OWNER. 6. CONSTRUCTION, MAINTENANCE AND REMOVAL OF ALL EROSION CONTROL DEVICES ARE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. TIMING OF REMOVAL SHALL BE COORDINATED WITH THE EROSION CONTROL INSPECTOR. 7. EXISTING UTILITIES AND STRUCTURES SHOWN, BOTH UNDERGROUND AND ABOVE GROUND, ARE BASED ON A FIELD SURVEY AND THE BEST AVAILABLE RECORD DRAWINGS. THE CONTRACTOR SHALL VERIFY FIELD CONDITIONS PRIOR TO BEGINNING RELATED CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY. 8. SOIL UNDER BUILDINGS, PAVED AREAS AND WITHIN SLOPES GREATER THAN 3:1 (H: V) SHALL BE APPROVED, PLACED AND COMPACTED AS RECOMMENDED BY THE GEOTECHNICAL ENGINEER. 9. GRADING CONTRACTOR SHALL BE RESPONSIBLE TO GRADE EACH LOT SUCH THAT POSITIVE DRAINAGE FROM THE HOUSE FOUNDATION IS PROVIDED AND WATER FROM A HIGHER ELEVATION ON ADJOINING LOTS IS DIVERTED THROUGH THE USE OF SWALES ALONG LOT LINES. THE GRADING CONTRACTOR SHALL ALSO ENSURE THAT PONDING ON INDIVIDUAL LOTS WILL NOT BE CREATED. 10. EXISTING VEGETATION AND NATURAL AREAS SHALL BE PROTECTED TO THE GREATEST EXTENT POSSIBLE. AD D ITI O NAL UTILITY NOTES 1. ALL WATER MAINS, SERVICES AND FIRE SERVICES GREATER THAN 2" DIAMETER ARE TO BE DUCTILE IRON PIPE. 2" & SMALLER DOMESTIC SERVICES MUST BE TYPE K SOFT COPPER (WITHOUT FITTINGS) TO THE WATER METER. 2. ALL SEWER MAINS SHALL BE EITHER PVC OR DUCTILE IRON PIPE AS SHOWN ON THE PLANS. ALL PIPE MATERIAL SHALL MEET CITY OF RALEIGH STANDARDS AND SPECIFICATIONS AS DEFINED IN THE LATEST ISSUE OF THE PUBLIC UTILITIES HANDBOOK AND/OR UNIFIED DEVELOPMENT ORDINANCE (UDO). 3. ALL FIRE HYDRANTS ALONG PUBLIC R/W LINES SHALL HAVE A 3'Wx3'L CITY OF RALEIGH WATERLINE EASEMENT ONTO ADJACENT PROPERTY. 4. ALL SANITARY SEWER INTERCEPTOR LINES (12" AND LARGER), AS WELL AS MANHOLES AND FITTINGS ASSOCIATED WITH THE INTERCEPTOR LINE, SHALL BE INTERNALLY LINED WITH PROTECTO 401 OR APPROVED EQUAL TO PREVENT HYDROGEN SULFIDE CORROSION. SEE THE CURRENT CITY OF RALEIGH PUBLIC UTILITIES DEPARTMENT HANDBOOK FOR APPROVED COATINGS AND APPLICATION METHODS. 5. IN ACCORDANCE WITH GENERAL STATUTE 87-121(G), ALL UNDERGROUND UTILITIES INSTALLED AFTER OCTOBER 1, 2014 SHALL BE ELECTRONICALLY LOCATABLE. CONTRACTOR SHALL COORDINATE DIRECTLY WITH THE CITY OF RALEIGH PUBLIC UTILITIES DEPARTMENT FOR DETAILS AND SPECIFICATIONS FOR MEETING THESE REQUIREMENTS. 6. EXISTING UTILITIES SHOWN ARE BASED ON FIELD SURVEYS AND THE BEST AVAILABLE RECORD DRAWINGS. THE CONTRACTOR SHALL VERIFY CONDITIONS PRIOR TO BEGINNING CONSTRUCTION. ANY DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND THE PLANS SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY. 7. ALL WATER AND SEWER MAINS WITHIN PUBLIC EASEMENTS OR RIGHTS-OF-WAY TO BE OWNED, OPERATED, AND MAINTAINED BY THE CITY OF RALEIGH. 8. ALL WATER AND SEWER MAINS NOT WITHIN PUBLIC EASEMENTS OR RIGHTS-OF-WAY TO BE PRIVATELY OWNED, OPERATED, AND MAINTAINED BY THE PROPERTY OWNER. 9. CONTRACTOR SHALL NOTIFY "NC811" (811) OR (1-800-632-4949) AT LEAST 3 FULL BUSINESS DAYS PRIOR TO BEGINNING CONSTRUCTION OR EXCAVATION TO HAVE EXISTING UTILITIES LOCATED. CONTRACTOR SHALL CONTACT ANY LOCAL UTILITIES THAT PROVIDE THEIR OWN LOCATOR SERVICES INDEPENDENT OF "NC811". REPORT ANY DISCREPANCIES TO THE ENGINEER IMMEDIATELY. 10. ALL UTILITY SLEEVES SHALL BE SCHEDULE 40 PVC AND INSTALLED WITH 2' MINIMUM COVER. BOTH ENDS SHALL BE CAPPED AND MARKED. STORM DRAINAGE NOTES 1. ALL STORM DRAINAGE PIPES SHOWN SHALL BE CLASS III REINFORCED CONCRETE (RCP) UNLESS NOTED OTHERWISE. 2. ALL STORM DRAINAGE CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE TOWN OF WAKE FOREST STANDARDS. 3. ALL CONCRETE SHALL MEET A MINIMUM 3000 PSI COMPRESSIVE STRENGTH. 4 ALL PIPE IN STORM DRAIN STRUCTURES SHALL BE STRUCK EVEN WITH INSIDE WALL. 5. ALL PIPE JOINTS SHALL BE MADE WITH PREFORMED JOINT SEALER, WHICH CONFORMS TO AASHTO SPECIFICATION M-198 FOR TYPE B FLEXIBLE PLASTIC GASKETS UNLESS OTHERWISE NOTED. 6. THE INTERIOR SURFACES OF ALL STORM DRAINAGE STRUCTURES SHALL BE POINTED UP AND SMOOTHED TO AN ACCEPTABLE STANDARD, USING MORTAR MIXED TO MANUFACTURER'S SPECIFICATIONS. 7. ALL BACKFILL SHALL BE NON -PLASTIC IN NATURE, FREE FROM ROOTS, VEGETATION MATTER, WASTE CONSTRUCTION MATERIAL OR OTHER OBJECTIONABLE MATERIAL. SAID MATERIAL SHALL BE CAPABLE OF BEING COMPACTED BY MECHANICAL MEANS AND SHALL HAVE NO TENDENCY TO FLOW OR BEHAVE IN A PLASTIC MANNER UNDER THE TAMPING BLOWS OR PROOF ROLLING. 8. MATERIALS DEEMED BY THE OWNER'S REPRESENTATIVE OR GEOTECH AS UNSUITABLE FOR BACKFILL PURPOSES SHALL BE REMOVED AND REPLACED WITH SUITABLE MATERIAL. 9. BACKFILLING OF TRENCHES SHALL BE ACCOMPLISHED IMMEDIATELY AFTER PIPE IS LAID. THE FILL AROUND THE PIPE SHALL BE THOROUGHLY COMPACTED TO 95 % OF THE MAXIMUM DRY DENSITY OBTAINABLE WITH THE STANDARD PROCTOR TEST. THE TOP EIGHT (8) INCHES SHALL BE COMPACTED TO 100 PERCENT STANDARD PROCTOR. 10. UNDER NO CIRCUMSTANCES SHALL WATER BE ALLOWED TO RISE IN UNBACKFILLED TRENCHES AFTER PIPE HAS BEEN PLACED. 11. ALL CONCRETE PIPE AND PRECAST STORM STRUCTURES SHALL MEET NCDOT STANDARDS AND STAMPED ACCORDINGLY BY MANUFACTURER. 12. CONTRACTOR SHALL BE RESPONSIBLE FOR CHECKING ALL PIPE AND STRUCTURES FOR CRACKS OR BREAKS, PRIOR TO INSTALLATION. ANY DAMAGED ITEMS SHALL NOT BE INSTALLED. CITY OF RALEIGH PUBLIC UTILITIES STAN DAR D UTILITY NOTE5 CAS AP P LI CAB LES 1. ALL MATERIALS & CONSTRUCTION METHODS SHALL BE IN ACCORDANCE WITH CITY OF RALEIGH DESIGN STANDARDS, DETAILS & SPECIFICATIONS (REFERENCE: CORPUD HANDBOOK, CURRENT EDITION). 2. UTILITY SEPARATION REQUIREMENTS: d) A DISTANCE OF 100' SHALL BE MAINTAINED BETWEEN SANITARY SEWER & ANY PRIVATE OR PUBLIC WATER SUPPLY SOURCE SUCH AS AN IMPOUNDED RESERVOIR USED AS A SOURCE OF DRINKING WATER. IF ADEQUATE LATERAL SEPARATION CANNOT BE ACHIEVED, FERROUS SANITARY SEWER PIPE SHALL BE SPECIFIED & INSTALLED TO WATERLINE SPECIFICATIONS. HOWEVER, THE MINIMUM SEPARATION SHALL NOT BE LESS THAN 25' FROM A PRIVATE WELL OR 50' FROM A PUBLIC WELL. b) WHEN INSTALLING WATER &/OR SEWER MAINS, THE HORIZONTAL SEPARATION BETWEEN UTILITIES SHALL BE 10'. IF THIS SEPARATION CANNOT BE MAINTAINED DUE TO EXISTING CONDITIONS, THE VARIATION ALLOWED IS THE WATER MAIN IN A SEPARATE TRENCH WITH THE ELEVATION OF THE WATER MAIN AT LEAST 18" ABOVE THE TOP OF THE SEWER & MUST BE APPROVED BY THE PUBLIC UTILITIES DIRECTOR. ALL DISTANCES ARE MEASURED FROM OUTSIDE DIAMETER TO OUTSIDE DIAMETER. c) WHERE IT IS IMPOSSIBLE TO OBTAIN PROPER SEPARATION, OR ANYTIME A SANITARY SEWER PASSES OVER A WATERMAIN, DIP MATERIALS OR STEEL ENCASEMENT EXTENDED 10' ON EACH SIDE OF CROSSING MUST BE SPECIFIED & INSTALLED TO WATERLINE SPECIFICATIONS. d) 5.0' MINIMUM HORIZONTAL SEPARATION IS REQUIRED BETWEEN ALL SANITARY SEWER & STORM SEWER FACILITIES, UNLESS DIP MATERIAL IS SPECIFIED FOR SANITARY SEWER. e) MAINTAIN 18" MIN. VERTICAL SEPARATION AT ALL WATERMAIN & RCP STORM DRAIN CROSSINGS; MAINTAIN 24" MIN. VERTICAL SEPARATION AT ALL SANITARY SEWER & RCP STORM DRAIN CROSSINGS. WHERE ADEQUATE SEPARATIONS CANNOT BE ACHIEVED, SPECIFY DIP MATERIALS & A CONCRETE CRADLE HAVING 6" MIN. CLEARANCE (PER CORPUD DETAILS W-41 & S-49). f) ALL OTHER UNDERGROUND UTILITIES SHALL CROSS WATER & SEWER FACILITIES WITH 18" MIN. VERTICAL SEPARATION REQUIRED. 3. ANY NECESSARY FIELD REVISIONS ARE SUBJECT TO REVIEW & APPROVAL OF AN AMENDED PLAN &/OR PROFILE BY THE CITY OF RALEIGH PUBLIC UTILITIES DEPARTMENT PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL MAINTAIN CONTINUOUS WATER & SEWER SERVICE TO EXISTING RESIDENCES & BUSINESSES THROUGHOUT CONSTRUCTION OF PROJECT. ANY NECESSARY SERVICE INTERRUPTIONS SHALL BE PRECEDED BY A 24 HOUR ADVANCE NOTICE TO THE CITY OF RALEIGH PUBLIC UTILITIES DEPARTMENT. 5. 3.0' MINIMUM COVER IS REQUIRED ON ALL WATER MAINS & SEWER FORCEMAINS. 4.0' MINIMUM COVER IS REQUIRED ON ALL REUSE MAINS. 6. IT IS THE DEVELOPER'S RESPONSIBILITY TO ABANDON OR REMOVE EXISTING WATER & SEWER SERVICES NOT BEING USED IN REDEVELOPMENT OF A SITE UNLESS OTHERWISE DIRECTED BY THE CITY OF RALEIGH PUBLIC UTILITIES DEPARTMENT. THIS INCLUDES ABANDONING TAP AT MAIN & REMOVAL OF SERVICE FROM ROW OR EASEMENT PER CORPUD HANDBOOK PROCEDURE. 7. INSTALL 3/4" COPPER* WATER SERVICES WITH METERS LOCATED AT ROW OR WITHIN A 2'X2' WATERLINE EASEMENT IMMEDIATELY ADJACENT. NOTE: IT IS THE APPLICANT'S RESPONSIBILITY TO PROPERLY SIZE THE WATER SERVICE FOR EACH CONNECTION TO PROVIDE ADEQUATE FLOW & PRESSURE. 8. INSTALL 4" PVC* SEWER SERVICES ® 1.0% MINIMUM GRADE WITH CLEANOUTS LOCATED AT ROW OR EASEMENT LINE & SPACED EVERY 75 LINEAR FEET MAXIMUM. 9. PRESSURE REDUCING VALVES ARE REQUIRED ON ALL WATER SERVICES EXCEEDING 80 PSI; BACKWATER VALVES ARE REQUIRED ON ALL SANITARY SEWER SERVICES HAVING BUILDING DRAINS LOWER THAN 1.0' ABOVE THE NEXT UPSTREAM MANHOLE. 10. ALL ENVIRONMENTAL PERMITS APPLICABLE TO THE PROJECT MUST BE OBTAINED FROM NCDWQ, USACE &/OR FEMA FOR ANY RIPARIAN BUFFER, WETLAND &/OR FLOODPLAIN IMPACTS (RESPECTIVELY) PRIOR TO CONSTRUCTION. 11. NCDOT / RAILROAD ENCROACHMENT AGREEMENTS ARE REQUIRED FOR ANY UTILITY WORK (INCLUDING MAIN EXTENSIONS & SERVICE TAPS) WITHIN STATE OR RAILROAD ROW PRIOR TO CONSTRUCTION. 12. GREASE INTERCEPTOR / OIL WATER SEPARATOR SIZING CALCULATIONS & INSTALLATION SPECIFICATIONS SHALL BE APPROVED BY THE CORPUD FOG PROGRAM COORDINATOR PRIOR TO ISSUANCE OF A BUILDING PERMIT. CONTACT TIM BEASLEY AT (919) 996-2334 OR TIMOTHY.BEASLEY®RALEIGHNC.GOV FOR MORE INFORMATION. 13. CROSS -CONNECTION CONTROL PROTECTION DEVICES ARE REQUIRED BASED ON DEGREE OF HEALTH HAZARD INVOLVED AS LISTED IN APPENDIX -B OF THE RULES GOVERNING PUBLIC WATER SYSTEMS IN NORTH CAROLINA. THESE GUIDELINES ARE THE MINIMUM REQUIREMENTS. THE DEVICES SHALL MEET AMERICAN SOCIETY OF SANITARY ENGINEERING (ASSE) STANDARDS OR BE ON THE UNIVERSITY OF SOUTHERN CALIFORNIA APPROVAL LIST. THE DEVICES SHALL BE INSTALLED AND TESTED (BOTH INITIAL AND PERIODIC TESTING THEREAFTER) IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS OR THE LOCAL CROSS -CONNECTION CONTROL PROGRAM, WHICHEVER IS MORE STRINGENT. CONTACT JOANIE HARTLEY AT (919) 996-5923 OR JOANIE.HARTLEYORALEIGHNC.GOV FOR MORE INFORMATION. RETAINING WALL NOTES 1. THE RETAINING WALL ALIGNMENT SHOWN ON THESE PLANS DEPICTS THE LOCATION OF THE FRONT FACE OF THE RETAINING WALL AT THE TOP OF THE WALL. THE CONTRACTOR IS RESPONSIBLE FOR ENSURING RETAINING WALLS ARE NOT LOCATED IN ANY STREAM BUFFERS, AND THEIR CONSTRUCTION DOES NOT ENCROACH INTO ANY ADJACENT PROPERTIES DUE TO ANY BATTER INCORPORATED IN THE DESIGN OF THE WALLS. 2. RETAINING WALLS ARE TO BE DESIGN -BUILD PROJECTS BY THE CONTRACTOR. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN FINAL CONSTRUCTION DRAWINGS FROM A REGISTERED ENGINEER AND GAIN ALL REQUIRED PERMITS NECESSARY FOR THE CONSTRUCTION OF THE RETAINING WALLS. 3. RETAINING WALLS SHALL BE ASSUMED TO BE BACKFILLED WITH OFF-SITE BORROW MATERIAL OR PROCESSED FILL, UNLESS THE CONTRACTOR CAN PROVIDE TO THE OWNER WITH CONFIRMATION FROM THE GEOTECHNICAL ENGINEER AND THE RETAINING WALL DESIGNER, THAT READILY AVAILABLE ON-SITE SOILS CAN BE USED. 4. THE TOP AND BOTTOM OF WALL ELEVATIONS SHOWN ON THESE PLANS IDENTIFY FINISHED GRADE ELEVATIONS ONLY. THE EXTENT THAT THE RETAINING WALL WILL BE EXTENDED BELOW GRADE TO THE FOOTING OR ABOVE GRADE TO THE TOP OF THE CAP BLOCK COURSE SHALL BE IDENTIFIED ON THE RETAINING WALL CONSTRUCTION DRAWINGS. 5. ALL RETAINING WALLS OVER 30" HIGH SHALL HAVE A SAFETY FENCE (DESIGN BY OTHERS). 6. ANY PART OF ANY RETAINING WALL THAT EXTENDS INTO THE RIGHT-OF-WAY WILL REQUIRE AN ENCROACHMENT AGREEMENT. ENCROACHMENT AGREEMENTS FOR RETAINING WALLS SHALL BE APPROVED PRIOR TO CONSTRUCTION DRAWING APPROVAL. 7. ANY TIEBACK SYSTEMS FOR THE RETAINING WALLS SHALL NOT BE ALLOWED WITHIN PUBLIC RIGHT-OF-WAY. 8. STORMWATER RUN-OFF SHALL BE DIRECTED AWAY FROM RETAINING WALLS. ANY RUN-OFF FLOWING TO AND OVER A RETAINING WALL SHALL BE KEPT TO AN ABSOLUTE MINIMUM AND BROUGHT TO THE ATTENTION OF THE WALL DESIGNER PRIOR TO THEIR DESIGN. THESE PLANS HAVE BEEN APPROVED FOR CONSTRUCTION BY THE TOWN OF WAKE FOREST 5_/_-'>)J J6 bate Date - a,>, Date Date Date Date Urban` Forestry Date City of Raleigh Public Utilities Department Date ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH TOWP OF WAKE FOREST, CITY OF RALEIGH & NCDOT (WHERE APPLICABLE) STANDARDS, SPECIFICATIONS, AND DETAILS. HORIZONTAL DATUM: NAD83 VERTICAL DATUM: NGVD29 FINAL DRAWING - RELEASED FOR CONSTRUCTION M p �N U M a U0 voli 00 �4z tiv ocICO N.rih S �J CA 2 680 - tigTy'vc r rlti�• o N G. I� O W aC4 aQ W 1fJ OWC�C\2 a © C� A � � V Q ocqm 1 z 0 Z w0z 0 f� V PROJECT No. JPM-15010 FH,ENAME: JPM15010-N1 DESIGNED BY: N D W DRAWN BY: DLP SCAM: N.T.S. DATE: 04-04-2016 SHEET N0. C -3- '!I MCADAMS MAIL PARKING INSET'S SCALE: 1"=20' 13B TYPE IV MAIL KIOSK SCALE: NTS TA 29+79,35 TRADITIONS RIDGE AD = / / (TIE ,TO`EXISTIN 30" STAND RD CL ROYAL MILL AVENUE / -' CURB AND G0'&R AND TIE TO EXISTING 30" STANDARD / EXISTING%ASPHALT ( ) CURB AND GUTTER AND „N C� EXISTING ASPHALT (TYP.) d _ 4_ — _ 2C w' PROPOSED 1 C _ ASPHALT ' " _ 'MULTI=OSE TRAIL (CURRENTLY UNDER CONSTRUCTION) ----------------- - � - �'-'---------- '— 8' WIDE ACCESSIBLE _ z RAMP (TYP ) U w PC 11 +40.67 k- 30,R�, 30'R 30" STANDARD -.-CURB` �• m _ AND (TYP.)25' REAR SETBACK i I. STA 14+01. 9 S R OWHAWK LANE _ (�'•) 10+00.00 MEADOW R V DRIVE EX. 20' SANITARY �. r„ 11' 111 -1 1 SEWER EASEMENT ' / (B.M. 2009, PG. 172) ' STOP SIGN I O,R (TYP.) �,,.. 20' I 25' STREET 10,371 SF 15,063 SF -�,.2g=+ 2�3g�_� ' YARD BUFFER T TRANSITION FROM 30" VALLEY TO rn STANDARD CURB AND 1 O 1 8' SIDE SETBACK 1 + w 453 (GUTTER (TYP.) 8 680 SF + (nP•) I 15'x15' TOWN OF WAKE FORES ro `` ' o � SIGHT DISTANCE TRIANGLE / ' 10,803 SF M � 454 I (TYP-) ' PC=28+64.02 7 it " 11,660 SF� ' 30" VALLEY CURB 30 STANDARD CURBL- AND GUTTER (TYP.) 1 15x151 TOWN OF WAKE FOREST 4 SND GUTTER tJTYP•} �" SIGHT (STANCE TRIANGLE 25' REAR SETBACK_ "'�--- _ _ 1_ � STOP SIGN 5' CONCRETE _____--S.TYP-) - ---•_ _ _ 0'R (TYP•) SIDEWALK ('•) L STA. 28+08.89 TRA T S RIDG 0 ' 30' ' 13+00 +00.00 SPARROWHAWK LANE ' 12+00 330.24' — }-- 4=500-Oh'L=17.55 10 oo 11+00 i-_____-- — t------- -- i------ — �"— N57 s2'ss"w (NO 25' REAR SETBA (TY'-) z o N E O n- 0 N N Cv 1 P.I. STA. 25+26.37 TI 10+00.00 HYDRANGEA 15' CO ' 5' TRANSITION FROM 30" 4 00' POIR VALLEY TO STANDARD ate 'i 2ENGE FUND) ' ' CURB AND GUTTER (TYP.) 60' R/IN 8,875 SF CONCRETE PAD :.................... MAINTENANCE Ero & S-di--nt Control EASEMENT (TYP. 1 O Fir -t' 'LO 8,281 SF LU 0> co 1 Acce ility � i ::::::::::::: ::::::::::::::::::::::: ::::::::::�::: U ::::::::::::::::;::::::::::::::::... CBU ::_ .: CB ..... .. ..... .........•.::::.....:::::::::...........: ........................,. 1....... i....... .' :::.....::.............' 15'X10' PRIVATE ACCESS EASEMENT 8,281 SF 01 — ........ ....... • • CBU :::::::::: CBU :::::::::::::::::::: ( RIGHT OF WAY 41' MAIL PARKING INSET'S SCALE: 1"=20' 13B TYPE IV MAIL KIOSK SCALE: NTS TA 29+79,35 TRADITIONS RIDGE AD = / / (TIE ,TO`EXISTIN 30" STAND RD CL ROYAL MILL AVENUE / -' CURB AND G0'&R AND TIE TO EXISTING 30" STANDARD / EXISTING%ASPHALT ( ) CURB AND GUTTER AND „N C� EXISTING ASPHALT (TYP.) d _ 4_ — _ 2C w' PROPOSED 1 C _ ASPHALT ' " _ 'MULTI=OSE TRAIL (CURRENTLY UNDER CONSTRUCTION) ----------------- - � - �'-'---------- '— 8' WIDE ACCESSIBLE _ z RAMP (TYP ) U w PC 11 +40.67 k- 30,R�, 30'R 30" STANDARD -.-CURB` �• m _ AND (TYP.)25' REAR SETBACK i I. STA 14+01. 9 S R OWHAWK LANE _ (�'•) 10+00.00 MEADOW R V DRIVE EX. 20' SANITARY �. r„ 11' 111 -1 1 SEWER EASEMENT ' / (B.M. 2009, PG. 172) ' STOP SIGN I O,R (TYP.) �,,.. 20' I 25' STREET 10,371 SF 15,063 SF -�,.2g=+ 2�3g�_� ' YARD BUFFER T TRANSITION FROM 30" VALLEY TO rn STANDARD CURB AND 1 O 1 8' SIDE SETBACK 1 + w 453 (GUTTER (TYP.) 8 680 SF + (nP•) I 15'x15' TOWN OF WAKE FORES ro `` ' o � SIGHT DISTANCE TRIANGLE / ' 10,803 SF M � 454 I (TYP-) ' PC=28+64.02 7 it " 11,660 SF� ' 30" VALLEY CURB 30 STANDARD CURBL- AND GUTTER (TYP.) 1 15x151 TOWN OF WAKE FOREST 4 SND GUTTER tJTYP•} �" SIGHT (STANCE TRIANGLE 25' REAR SETBACK_ "'�--- _ _ 1_ � STOP SIGN 5' CONCRETE _____--S.TYP-) - ---•_ _ _ 0'R (TYP•) SIDEWALK ('•) L STA. 28+08.89 TRA T S RIDG 0 ' 30' ' 13+00 +00.00 SPARROWHAWK LANE ' 12+00 330.24' — }-- 4=500-Oh'L=17.55 10 oo 11+00 i-_____-- — t------- -- i------ — �"— N57 s2'ss"w (NO 25' REAR SETBA (TY'-) z o N E O n- 0 N N Cv 1 P.I. STA. 25+26.37 TI M 0- N RETAINING WALL #1- c (BY `OTHERS) EXISTING C11 RALEIGH 30' SEWER EASE (B.M. 1999; 8,875 SF 10+00.00 HYDRANGEA ACCESSIBLE RAMP (MODIFIED TYPE 3 TYP.) CO ' 5' TRANSITION FROM 30" 4 00' POIR VALLEY TO STANDARD ate 'i 2ENGE FUND) ' ' CURB AND GUTTER (TYP.) 60' R/IN 8,875 SF 8' PRIVATE WADI - MAINTENANCE Ero & S-di--nt Control EASEMENT (TYP. 1 O Fir -t' 'LO M 0- N RETAINING WALL #1- c (BY `OTHERS) EXISTING C11 RALEIGH 30' SEWER EASE (B.M. 1999; 8,875 SF S ACCESSIBLE RAMP (MODIFIED TYPE 3 TYP.) CO ' 5' TRANSITION FROM 30" 00' POIR VALLEY TO STANDARD ate 'i 2ENGE FUND) ' ' CURB AND GUTTER (TYP.) 60' R/IN 8,875 SF 35' B-13 �r- < Ero & S-di--nt Control Date Fir -t' Date 8,281 SF LU 0> co 1 Acce ility � i Date 8,281 SF 01 r'' 448 ' 8,281 SF '5' CONCRETE 30' O'DITIO11 RIDGE, ROAD = SIDEWALK 10 ��i 5827" FIELD URT ACCESSIBLE RAMP 1 59.72• ' 5' TYPE- - - --_ _ _ 0 30'R ' 447 30" STANDARD�CURB "' 0' 1 8,281 SF AND GUTTER (' .) 30" VALLEY CURB --.+-SND GUTTERI(TYP.) ' THESE PLANS HAVE BEEN APPROVED FOR CONSTRUCTION BY THE TOWN OF WAKE FOREST Eng' eer Department ate 'i x/16 P blit Wor Departm Date �r- < Ero & S-di--nt Control Date Fir -t' Date / l+% le" 1 Acce ility � i Date t31-�' City of Raleigh Public Utilities Department Date Date s/I I /I Date ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH TOWN OF WAKE FOREST, CITY OF RALEIGH & NCDOT (WHERE APPLICABLE) STANDARDS, SPECIFICATIONS, AND DETAILS. HORIZONTAL DATUM: NAD83 VERTICAL DATUM: NGVD29 - FLOODWAY EXISTING CITY OF RALEIGH 30' SANITARY SEWER EASEMENT BM 1998 PG 1731 & 1730 30' CITY OF RALEIGH > SANITARY SEWER EASEMENT & TOWF GREENWAY EASEMENT / 1 F 1\ J IABLE --WIDTH PUBLIt� R ; W �^ r N r .1 FINAL DRAINING — GRELEASED FOR CONSTRUCTION CO • N ;�U M �q O �i 0 vgz OU c wM i N CO vim�^�y VJ AR • S/ 4680 /vG 1 NE��'�• 4� IV G '• .� r,, O co W Q{Zi aA H 1O W W .--4 QI w W E+ o U E--'�4 a a 000w G\2 V AA Cy A 1 �Z0 a 0 z w W r� PROJECT NO. JPM-15010 FIMNAME: JPM15010—S1 DESIGNED BY: N D W DRAWN BY: DLP SCALE: 1 " = 50' DATE' 04-04-2016 SHEET NO. C-4 11, J McADAMs .w r�++)YI R=20.00' L=35.42' pgovo5E °CD ' i EX. 20 SANITARY 58' SEWER EASEMENT (B.M. 2009, PG. 172)2) ') --_ _ ' L=29.89 `O _ N32'47' 14"E 453 3.85' < f f 10,803 SF a 't' j r w , 25' STREET - --- _ S4T,59 E 0 o 15,063 SF -- _ ---- , Mt - 5' TYPE 'B' ,,,-5' M p 8,875 SF oto " w z ' ----- _ 247*59113"E 30' CITY OF t 25.00' "--- _ q 1 I ' t (4-51) M� EXISTING 100' ' POWER EASEMENT (NO REFERENCE FOUND) N4.58'18"W .1p6�2S' / 335.22'N44'18'00"1N7zzzR4''18'00�"ly"_-- \ \ 53.49' / ! 100 YEAR ! FLOOD PLAIN° °' V 1 A 1 tkrn A\ \ t ti, �o ��05 465 .410 N . °o �s, 13.518 SF!N s� o!cv, a� o 11,653 SF \ 25' STREET YARD 1Z k \ BUFFER /t!Q� Q N q.64• �� �� 20' TOWN OF WAKE X69 1�1 1• 1=?/ FOREST GREENWAY �S 5N 15,725 SF X50.00' EASEMENT =42.11 ��dS�O R o' ``� ti 467 N40.45'06"E A y N 1• " --�-.. _ S46'45'45'E Q� /� 18.81' 8 cn - ' �- _ 11 141.80'_0 11,$16 SF t, , wjo N18'21'10"E m y N S53'4d'S5"E 10.74' i\ f) R=20.00' l w - - - - - - B L=28.61' N > �o146.22'� l 17,045 SF 11,408 SF 468 _ t « R=25.00' i \- �1 N R=25.00' m N N L=21.03' 11 967 SF �`S55'32' 19"E L=21-03' tO J `O ' o \ 153.33' _ _ b, �' o in \ � 0 , '5A v 5A"v 125.92' 09. /q4.3 N55'32 19"W m 1 \ rn a 129• S53.40'55"E t c°'ijo 848 N6g585 1 20' PRIVATE STORM N 185.05' N55'32'19"W DRAINAGE EASEMENT o w 50 N685s 27.4,'TYP.) 462 R W (` \ MEADOW; GROVE I�R VE O � GOLDFINCH NEST COURT, } f R_ L=14.33 (50' PUBLIC R/) ___ 9,533 SF r (50' PUBLIC R/W)S34 74.00'41 "W ' I ( 74.00' . L i w b R=325.00' N S55'32'19"E rn 0 L=36.75' 13,595 SF r� 'I� 460 j -- --131.03'-- -- ( 011 (j \ n ni ni i - - 124_99' 553'40'55"E w R PW rn) v 11,058 SF N53'40'S5"W - 201.99' - - - 77.00'Ilk V 459 0 ! N53'40'55"W m , � N34'27'41 "E or - z ~� 11,388 SF 1 160.00' 1 W I 461Wo o o I 10,927 SF � J m �! t I I N49'77'19"E Q'CO t ' J 3.36' o CO R=325.00' M o L=73.57' I R=20.00' u p ! o R=20.00' 470 1 W L=31.42' ( t L=28.80' 3.36' 17' 19"W 15,740 SF :- , ¢ to I S55'32'19"E S5532'19"E I I 1S55'32'19"E R=325.00' Z 471 z� 62.00' 70.50' 57.65' L=41.59 9,737 SF rn R=20.00' ' p %� u u /� L=28.78' R=50.00' t S1 ARRV"IiAi, ■'^NE vi L=23.63' R=500.00' - � to 288.65_ -R/W-)- -57-32'58"W � a- R=325.00' t 330.2_ 4__ - 2 L=61.36' -�50 PUBLIC R L=17.55' 11 -w f - -- - N57'32'58 W R=475.00' �C R=25.00' L=16.67 4, �� R\ L=30.77' 52.47 _76.00' _ _ 76.00' _ - _ 76.00' _ 52.13' R=275.00' \�00 0 52� R S0 74.00 N55'32'19"W N55'32'19"lM N553219"W N55 -'32'19"W L=23.90 >> Q" ? 1a X00' __28.48 _ _72.18' ." .. - " " N5T32'58"W S2 7fi'` Wh /DOS ' N5732'58W N5T32'58 4Y _ R�?�SOO 3s� �93���E o N5T32'58"W �� N5532'19"W 1 t 1?846r 30' CITY OF RAI SIGH 1 8.53' i t I i 1 SANITARY SEWER R=20.00' EASEMENT & TOWF f M L=28'07 i y GREENWAY EASE%NT 1\= �(A 479 � � I y / 21 -IF N32.36'05"W^'z20.00'w9.437 SF 9500 SF i 1" 9 243 SF o f 9,190 SF o io l P w w ? 9,037 SF "I a? 9,120 SF 9,681 SF w 476 m A>gl cl ^' o �; w / R=275.00' 1 10,621 SF I 12' PRIVATE WALL ri I m I 475 / L=6.68' MAINTENANCE i I 12 032 SF ' y i EASEMENT (TYP.) 125 00 S4158�27" y ( S55'32'19"E S55'32'19"E ( 474 5 3 S2T0T12 w Yt 1 III - E _-__ i I 3 t 111.14' 8.4T � 4i' / 1,3 _ ^ 2. S41'32'08"W 55'32'19 E '72, / 10,262 SF / 20.00' N 25.30' S5T18'13"E S57-18'1 YE 1 S3854'54"E ( / ddd S5T18'73"E 76.00' " 7.51' VARIABLE WIDTH 450 M xW� o M w S5T18.13"E 74.00' - _73.38' - - - 67.56'- - i ( S5625'S0"E / ` _ Ot"' Q) , _ - - - 82.78' ^ "�, 538 4. / ate/ PUBLIC STORM .n 85_15' _ f S4 f _ 21.14' ` \ 8 281 SF cv d o o _ 75.00' ^tN 484 ,N� off.-_ -72.31''. .._70AO'7 ' � N57-18'1 3W � w to 63.gg..,, =1 - - / / DRAINAGE EASEMENT N o rn !d of .,„., N5T18'13"N! / S5625'50"E t� . Z 11 448 4.92• I �..�/ y./L / N5T04'23 w W �yN 457 R=20.00' L=29.91' .�- '� , 25' STREET L4 456 Nt� 15,063 SF -- _ ---- - 5' TYPE 'B' ,,,-5' YARD BUFFER " w r±S32.47'14"W 30' CITY OF \ ,� �� w 1 NIS BUFFER -'- ---.__ ,_ S4T�13"E � 0ICA 10,371 SF -- ----- - 335.62' 3.85' RALEIGH SANITARY SEWER EASEMENT J E `\ \ \ � 455 m, _ t}1 i 70.00' 74.00 0 454 0 m 8,680 SF ( d�d?� I R=20.00' L=31.42' to N5T04'23 W I �R ' 490 •�/ 11) R -M Cc cN.. OPEN SPACE /�� �,�� \ �_ 2O' PUBLI( mac-^" DRAINAGE: ° J 11,660 SF S5532'19"E I i ' 8.50' R=525.00' R=20.00' L=34'82' S5T32'58"E 1 - S5T32'58"E y _ �, S5T32'S8"E L=18.43' 35.60' S5T3t58"E - -70.54 -- 70.54' 70.54' 95.26' N4.58'18"W .1p6�2S' / 335.22'N44'18'00"1N7zzzR4''18'00�"ly"_-- \ \ 53.49' / ! 100 YEAR ! FLOOD PLAIN° °' V 1 A 1 tkrn A\ \ t ti, �o ��05 465 .410 N . °o �s, 13.518 SF!N s� o!cv, a� o 11,653 SF \ 25' STREET YARD 1Z k \ BUFFER /t!Q� Q N q.64• �� �� 20' TOWN OF WAKE X69 1�1 1• 1=?/ FOREST GREENWAY �S 5N 15,725 SF X50.00' EASEMENT =42.11 ��dS�O R o' ``� ti 467 N40.45'06"E A y N 1• " --�-.. _ S46'45'45'E Q� /� 18.81' 8 cn - ' �- _ 11 141.80'_0 11,$16 SF t, , wjo N18'21'10"E m y N S53'4d'S5"E 10.74' i\ f) R=20.00' l w - - - - - - B L=28.61' N > �o146.22'� l 17,045 SF 11,408 SF 468 _ t « R=25.00' i \- �1 N R=25.00' m N N L=21.03' 11 967 SF �`S55'32' 19"E L=21-03' tO J `O ' o \ 153.33' _ _ b, �' o in \ � 0 , '5A v 5A"v 125.92' 09. /q4.3 N55'32 19"W m 1 \ rn a 129• S53.40'55"E t c°'ijo 848 N6g585 1 20' PRIVATE STORM N 185.05' N55'32'19"W DRAINAGE EASEMENT o w 50 N685s 27.4,'TYP.) 462 R W (` \ MEADOW; GROVE I�R VE O � GOLDFINCH NEST COURT, } f R_ L=14.33 (50' PUBLIC R/) ___ 9,533 SF r (50' PUBLIC R/W)S34 74.00'41 "W ' I ( 74.00' . L i w b R=325.00' N S55'32'19"E rn 0 L=36.75' 13,595 SF r� 'I� 460 j -- --131.03'-- -- ( 011 (j \ n ni ni i - - 124_99' 553'40'55"E w R PW rn) v 11,058 SF N53'40'S5"W - 201.99' - - - 77.00'Ilk V 459 0 ! N53'40'55"W m , � N34'27'41 "E or - z ~� 11,388 SF 1 160.00' 1 W I 461Wo o o I 10,927 SF � J m �! t I I N49'77'19"E Q'CO t ' J 3.36' o CO R=325.00' M o L=73.57' I R=20.00' u p ! o R=20.00' 470 1 W L=31.42' ( t L=28.80' 3.36' 17' 19"W 15,740 SF :- , ¢ to I S55'32'19"E S5532'19"E I I 1S55'32'19"E R=325.00' Z 471 z� 62.00' 70.50' 57.65' L=41.59 9,737 SF rn R=20.00' ' p %� u u /� L=28.78' R=50.00' t S1 ARRV"IiAi, ■'^NE vi L=23.63' R=500.00' - � to 288.65_ -R/W-)- -57-32'58"W � a- R=325.00' t 330.2_ 4__ - 2 L=61.36' -�50 PUBLIC R L=17.55' 11 -w f - -- - N57'32'58 W R=475.00' �C R=25.00' L=16.67 4, �� R\ L=30.77' 52.47 _76.00' _ _ 76.00' _ - _ 76.00' _ 52.13' R=275.00' \�00 0 52� R S0 74.00 N55'32'19"W N55'32'19"lM N553219"W N55 -'32'19"W L=23.90 >> Q" ? 1a X00' __28.48 _ _72.18' ." .. - " " N5T32'58"W S2 7fi'` Wh /DOS ' N5732'58W N5T32'58 4Y _ R�?�SOO 3s� �93���E o N5T32'58"W �� N5532'19"W 1 t 1?846r 30' CITY OF RAI SIGH 1 8.53' i t I i 1 SANITARY SEWER R=20.00' EASEMENT & TOWF f M L=28'07 i y GREENWAY EASE%NT 1\= �(A 479 � � I y / 21 -IF N32.36'05"W^'z20.00'w9.437 SF 9500 SF i 1" 9 243 SF o f 9,190 SF o io l P w w ? 9,037 SF "I a? 9,120 SF 9,681 SF w 476 m A>gl cl ^' o �; w / R=275.00' 1 10,621 SF I 12' PRIVATE WALL ri I m I 475 / L=6.68' MAINTENANCE i I 12 032 SF ' y i EASEMENT (TYP.) 125 00 S4158�27" y ( S55'32'19"E S55'32'19"E ( 474 5 3 S2T0T12 w Yt 1 III - E _-__ i I 3 t 111.14' 8.4T � 4i' / 1,3 _ ^ 2. S41'32'08"W 55'32'19 E '72, / 10,262 SF / 20.00' N 25.30' S5T18'13"E S57-18'1 YE 1 S3854'54"E ( / ddd S5T18'73"E 76.00' " 7.51' VARIABLE WIDTH 450 M xW� o M w S5T18.13"E 74.00' - _73.38' - - - 67.56'- - i ( S5625'S0"E / ` _ Ot"' Q) , _ - - - 82.78' ^ "�, 538 4. / ate/ PUBLIC STORM .n 85_15' _ f S4 f _ 21.14' ` \ 8 281 SF cv d o o _ 75.00' ^tN 484 ,N� off.-_ -72.31''. .._70AO'7 ' � N57-18'1 3W � w to 63.gg..,, =1 - - / / DRAINAGE EASEMENT N o rn !d of .,„., N5T18'13"N! / S5625'50"E t� . Z 11 448 W� I �..�/ y./L _ . -- 90.71' _ ,-.----- 70.00 ! _ _�R=25.00' 39 70 75.00' N5T04'23 w �� �� `� "C 8,281 SF M w R=20.00' L=31.42' aI 43.67 _ HYDRANGEA FIELD COURT S5T04'23 E3 854 $gw ��\ - 5' TYPE 'B' ,,,-5' (do" zi o 545 58'27"E -' Tt�p 50' PUBLIC DLIC R S5T04'23"E - -tea--- 4.31' - �� 30' CITY OF \ ,� �� 50 NEUSE R BUFFER -'- ---.__ ,_ S4T�13"E }.�„� 9.72' � ---- - R=300.00' L=47.64' -- ----- - 335.62' ° RALEIGH SANITARY SEWER EASEMENT J E `\ \ \ � (MEASURED 125.00' '. _' "-•-•- ... _ t}1 70.00' 74.00 R=25.00' 22.67 L=21.02' %� / (TYP.) ! PRIVATE � \� \ OF BANK, EA � ,. d�d?� L• 9.72' =3 4TSg'27"►y 1251.61' 74.00' - - - 39.05' N5T04'23"W N5T04'23"W N5T04'23"W N5T04'23"W a �� _ N5T04'23 W I �R �� c� 490 •�/ 11) R -M Cc cN.. OPEN SPACE /�� �,�� \ �_ 2O' PUBLI( mac-^" DRAINAGE: THESE PLANS HAVE BEEN APPROVED FOR CONSTRUCTION BY THE TOWN OF WAKE FOREST Engine ing Department Date MM , �i/16 J�3� 1k�' City of Raleigh Public Utilities Department Date Date Date Date Date Date ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH TOWP OF WAKE FOREST, CITY OF RALEIGH & NCDOT (WHERE APPLICABLE) STANDARDS, SPECIFICATIONS, AND DETAILS. HORIZONTAL DATUM: NAD83 VERTICAL DATUM: NGVD29 SEE SHEET C-3 FOR ALL PROJECT, SITE, GRADING, STORM DRAINAGE AND UTILITY NOTES. FLOODWAY EXISTING CITY OF RALEIGH 30' SANITARY SEWER EASEMENT BM 1998 PG 1731 & 1730 I 8' PRIVATE JAHL MAINTENANCE EASEMENT ('T .)' GRAPHIC SCALE 50 0 25 50 100 1 inch = 50 ft. .may �y FINAL DRAWING - RELEASED FOR CONSTRITCTION M p y � v �Cq U co d C04 W f(Vp1, o2z 19 0 rl r� v V AR 4680 = G r-� WQ ►-a Q WW1 w � Z £� 0O1.4 W O W E-+ Q C) ~ w Na a a 0w G\2 I'- Ask U) Z O 0A Fi C O P+�+1 z w Q V PROJECT NO. JPM-15010 FILENAME: JPM15010-S2 DESIGNED BY: N D W DRAWN BY: DLP SCALE: 1 " = 50' DATE: 04-04-2016 sxz•;ET Na. C-5 'J1 MCADAMS U z c' 0 E 2 n a D 3 m 3 0 PAVEMENT MARKING - SIGNAGE NOTES: ALL INTERNAL STREETS POSTED SPEED = 20 MPH 1. ALL CONSTRUCTION SHALL CONFORM TO THE LATEST NORTH CAROLINA DEPARTMENT OF TRANSPORTATION (NCDOT)DESIGN !` AND/OR TOWN OF WAKE FOREST STANDARDS AND SPECIFICATIONS. SPEED = 20 MPH' 2. ALL SIGNS SHALL BE PRISMATIC AND ADHERE TO THE MINIMAL RETROREFLECTIVITY STANDARDS FOUND IN THE LATESTf VERSION OF THE MUTCD. ALL SIGNS MUST MEET MUTCD GUIDELINES FOR LETTER HEIGHT, LEITER CASE AND SIGN COLOR. 3. EXISTING SIGNS SHALL BE RELOCATED TO THE APPROPRIATE LOCATION IN THE FIELD. 4. ANY WARNING SIGN SHALL BE FLOURESCENT YELLOW GREEN PER THE TOWN'S REQUIREMENT. 5. ALL PAVEMENT MARKINGS SHALL BE THERMOPLASTIC AND ARE TO BE PLACED PER NCDOT STANDARDS / \ NCDOT DETAILS 1205.011205.12) (REFERENCE 2012, 6. SIGN DESIGNS FOR STREET NAME SIGNS SHALL BE APPROVED BY TRANSPORTATION AND FACILITIES DEPARTMENT STAFF ' TO ENSURE COMPLIANCE WITH MUTCD SPECIFICATIONS. DESIGNS MUST BE APPROVED BY TaF STAFF PRIOR TO ACCEPTANCE OF STREETS OR ISSUANCE OF 1ST CO. 7. SEE DETAIL SHEET D-3 FOR MORE INFORMATION. ' Ate" �f „ N „� a w1 .� Y, p ti R. Y N - O T3 ,y w.: N.. { / STOP SIGN EX. 20' SANITARY SEWER EASEMENT µ i ��, •- 1 I R1-1 (B.M. 2009, PG. 172) ' ' _ I T2 _ I BUFFER YAR 456 rSTOP sIGN 454 I' TOWN OF WAKE FOREST o SIGHT DISTANCE TRIANGLE R1-1 { 455 ' (TYP.) N t 453 15'x15' TOWN OF WAKE FOREST SIGHT DISTANCE 1 I (`TRIANGLE (TYP.) I EXISTING 100'—' POWER EASEMENT (NO REFERENCE FOUND) IS N �o 5Q,+ R/W on 0+L 0 a+00 f^ H �o / os , t 20. -- / 25' STREET YARD / BUFFER k / 458 STOP SIGN R1-1 \ 463 1 - �j -- 20' PRIVATE STORM i DRAINAGE EASEMENT --MEAD 0W GROVE`` 1 R VE 462 (50' PUBLIC R/lI) SEE SHEET P-9� SSTOP SIGN --, i 1 ACCESSIBLE RAMP J 1 6 3 f i I 480 TYP.(MODIFIED TYPE 3 ' o 479 ' 451 r ' 450 ,•1 1 �w'Joi wo 1 ®� ' 448 _ ACCESSIBLE RAMP (MODIFIED TYPE 3 TYP.) 0 +} 447 (+ it f ---_ 5 TYPE 'B' T3 ' -..,,,BUFFER 459 � 1 1 461 1 ACCESSIBLE RAMP (MODIFIED TYP.) TYPE 4AS ARROWHALAM (50' PUBUO IR/W) 483 r 482 481 { I i { I � 20' PRIVATE STORM ' { 1 I i DRAINAGE EASEMENT (TYP.) ' 487 ! 488 1 489 I STOP SIGN 485 4$6 { { { { R1 1 ! ` I MAIL KIOSK ' 1 EASEMENT \ (TYP.) oo HYDRANGE FIELD C I URT (50 P BLIC R/W) 15+00 m 16+00 i 1 ACCESSIBLE RAMP I (MODIFIED TYPE 3 TYP.) THESE PLANS HAVE BEEN APPROVED FOR CONSTRUCTION BY THE TOWN OF WAKE FOREST Engine0ing Department Date � olLy((t ublic Wor Department Date Erd's'joiVSediment Control Date ' Iv e, I 1 SEE HEET P-2 - k I TH.) � � ,� � ,ZONE -_� 14+00100 YEAR ZONE. 11+00 + 12+00 -i- 13+0FLOOD PLAIN " -}- { 1 15'x15' TOWN OF WAKE FOREST ' SIGHT DISTANCE TRIANGLE (TYP.) 496 � ACCESSIBLE RAMP (MODIFIED TYPE 4A TYP.) Urban F restry V //A City of Raleigh Public Utilities Department Date Date t Date Date Date ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH TOWN OF WAKE FOREST, CITY OF RALEIGH & NCDOT (WHERE APPLICABLE) STANDARDS, SPECIFICATIONS, AND DETAILS. HORIZONTAL DATUM: NAD83 VERTICAL DATUM: NGVD29 SEE 490 PRIVATE .- --' OPEN SPACE ' IN, ;, -- I 1 i HANDICAP SIGN �R7-8 (SEE DETAIL I i 30' CITY OF \ ---� RALEIGH SANITARY ON SHEET D-3)-- T3 24" WHITE CROSSWALK LINE (HIGH VISIBILITY) Urban F restry V //A City of Raleigh Public Utilities Department Date Date t Date Date Date ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH TOWN OF WAKE FOREST, CITY OF RALEIGH & NCDOT (WHERE APPLICABLE) STANDARDS, SPECIFICATIONS, AND DETAILS. HORIZONTAL DATUM: NAD83 VERTICAL DATUM: NGVD29 SEE SHEET C-3 FOR ALL PROJECT, SITE, GRADING, STORM DRAINAGE AND UTILITY NOTES. PAVEMENT MARKING LEGEND -\LANE LINESZMARKINGS T2 24" WHITE STOPBAR T3 24" WHITE CROSSWALK LINE (HIGH VISIBILITY) :N,,- TO 8" WHITE CROSSWALK LINE \ ALL PAVEMENT MARKINGS SHALL BE THERMOPLASTIC AND ARE TO BE PLACED PER NCDOT STANDARDS (REFERENCE NCDOT DETAILS (1205.01-1205.12) \ SIGNAGE LEGEND -- / R1-1 STOP SIGN 30" FLOODWAY EXISTING CITY OF RALEIGH 30' SANITARY SEWER EASEMENT BM 1998 PG 1731 & 1730 30' CITY OF RALEIGH SANITARY SEWER > EASEMENT & TOWF . GREENWAY EASEMENT GRAPHIC SCALE 50 0 25 50 100 1 inch = 50 ft. FINAL DRAWING — RELEASED FOR CONSTRUCTION M p G y'N tJ J a�U Wriz 'N OU i C, IS CAR . 4, '• •O z O W Q aQ a� H LO z 0 W H W z Q Q a 0w o q aG\2 �- V VJ � a r0 0 vV A WO w z 0 U a PROJECT NO. JP M —1 501 0 FluNAME: JPM15010—PM1 DESIGNED BY: N D W DRAWN BY: DLP SCAM 1 " = 50' DATE: 04-04-2016 SHEET N0. —15 11JI MCADAMS GRADING LEGEND C� FLARED END SECTION ENDWALL SECTION CATCH BASIN DROP INLET 0 JUNCTION BOX �- DRAINAGE FLOW ARROW 250.50 250.00 TOP & BOTTOM CURB ELEVATIONS \,M=223.00 -TOP OF WALL ELEVATION BW=213.00-BOTTOM OF WALL ELEVATION (NOTE: BOTTOM OF WALL IS GROUND ELEVATION NOT WALL FOUNDATION) +250.60 SPOT ELEVATION ot� 25STREET / i i \ \ YARN BUFFER J /�i \464 \ / ,��i/ i _ \ V A� �67 20' TOWN OF\ WAKES I I I 1 } E } FOREST GREENWAY I I I 1 i' EASEMENT I I f - I f I i A t 463Th } t. 23 LF �5" RCP 20' PRIVATE STORM 1 A - _ 14 8 I I\ DRAINAGE EASEMENT \ ®0. 8% I ~' -- /\ ) DI 216 \ / U ,'� _ _ - - '- - - --�- - - CB 221 - 22 LF 15" RCP X3$3.0 )� f 6 3 0 0.8s% - , / / CB -220 _ C I CB -215 - '� / 1 I 7 LF 15" RCP I 0 2.17% 462 h D 7T(R +t y( sx�.i� V L �j �" i CB -214 - / CB -21s i Q46J } 11 EX. 20' SANITARY =� / } ' i i EXIS613 ITY OF f AL GH 3t r >� ..r�'�-�_ .,- - '_ AA / / / } } } � t t - - - " - - - 77 LF 15-/ RCP � � SEWER EASEMENT �> - - \ \ t / / \ } ' } 95 LF 15" RCP i 174 LF 1 RCP % / } �SANI'(ARYSEWER EASE E (B.M. 2009, PG. 172) } �' _/ ` I . - - _ 5' T EET / t } } ®0.64% z 2.47% - tf 1 0 1.52 1 98 I�G 131 r& 73 YARD BUFFE t / � / � / / � 4 7 � } } } � � 4 ----CB-21 � � 23 LF 15" � RCP 45 / l Q I i 59 - / / I 23 1 1 1 I I \-- �i i F�. - t , 461 / I I i I 1 460 _ � 189 LF 15") R � � �� ' " \10' t 134 ILF 1 "RCP ®2.69% / 47 LF 18 SCP \ 1 vv_ 453 t / / / ®o. \\� ®?,J�1% I x 1 454 } i � / / � �. -� CB -213�- { i CB -20?/ / / / ` 46 LF 15" RCP �� I CB -222 1 1 I I I I 6 t } 1 FLOi 0 0.63% 50 P C1 �� � CB -20 s B 217 1 i 14 1 1 - T }CB -210 } s t \ i i ®10.92% I. I } } I2w I.F L 78 LF 24 -/RCP 1 1 } v` m -.. x _-� _ 3.07% i F z.. ,. z � � NIN CB -k8 \ - - - _ - CB -206 \ \ 30 LF 15" RCP \ i \ CB -211 ® 1.99% 135 LF 18" RCP 22 LF 24" RCP CB -205 \ j; v 0 1_89% 0 0.88% t t / » 43 LF 15 ®0.88% " RCP 1 L- �- t ca CB -204 �6 LF 15'�RCP 1 2.64% 45� \ \ \ \V 1 480 _ _ X479�' \ \ V C ��o i 4 8 i 112 PRIVATE WALL 1 t} 76 91 LF 24" RCP / 1 �� 1 CB�307 MAINTENANCE ®5.50% i (EASEMENT �TYP.)- _ - (RETAINING 1 i I " CB -20 �tMAL12 - - - - 123 LF 24 RCP / 1 i �, r -B-2021 / \ ----- _ t DI -105 ev EXISTING 100' (BY OTHERS _ - - - - �''___ 6 5Z� - _ I"�: \ \ \ 1 POWER EASEMENT \ \ 1 - (NO REFERENCE V A V A A V A A _ _ - - _ ---" i - `� LF 3� R Pi1 } � FOUND} s A A _ - 352.50 / 0.72% 450 - v i V v TW=346:70 - TREE SAVE (TYP.) � 473 \ V v / TW -342.40 '' - } _ v 0 PRIVATE 1 _ - P" f M " V v A \ �i ..;. , BW=,34220 50 LF 24" RCP / } 2 _ E-4 139 LFA 15 RCP v v i A i \ i SI�RM 1 ___ " �- -== -= - 0 5.39% / 1 A - _ ,. » . 0 2.52%\ v V A 1 DRAINAGE / TW=344.20 ^ r _ _ _ _ _ A i RIM 33 . 0 _ A TW=351).80 � \� i A �\ EASEMENT O 1 BW=342:80/ �• - - - - - 1 \ v \ \ V A BW -340. 0�. /� ` I ¢89 t �; _ i /2o PUBLIC Qy £ _ V A _ \3 \ \ V A t i %; TW=350.0 � � ��. ..2(L UBUC STORM � -STORII�DRAINA v ' 449w \ \ \ 1 488 \ " EASE fi SEE ITORM'�ATE �c A V I \ t 8W=34300 ,� , i DRAINAGE "EASEMENT $$ F�� `z 32 LF 18 ERCP A ! \ { \ 9 -LF 15 RCP " ��� _ SHEEfiS F V \ I A 4$ " 181 LF 18 RCP% / w C f h•y \ 0 0.77% \ \ 87 LF 1 h ®2.�6%� \ �; "� „�L I 0i 2.93% ` �; / DESi N - - - - [�j �"� £ \ 486 \ \ "\ O 286% AIL KIOSK 01 TW=346.OQ. �, - PRiVA / E - E..y 29 Lf 15 RCRt EASEMENT _ o 1 o CB 305 2.07% O TYP. � 48� ... t I � _ i / sLXSwxi�" - - . \THICK CLASS B - 46 LF 18" RCP \ g - \ \ � � .``�� `, .,\ � �\ RiP=►jAP PAD j � � `''"'�.. -.:•�- - - \ \ \ 1 Z:O: --=-r2 a ®1.51% 448 to CB 303A_ rFES-1Ans 3fi�" •�-' �'- THESE PLANS HAVE BEEN APPROVED FOR CONSTRUCTION BY THE TOWN OF WAKE FOREST Engmepring gepartment Date '114_1�12H / ff, Public Works DeparAment, Date I .Y'-13-- t t Eros' n Sediment Control Date 1^' -- Fire Prevention Date Date f Date Date '33 Srtt/I� City of Raleigh Public Utilities Department Date ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH TOWN OF WAKE FOREST, CITY OF RALEIGH & NCDOT (WHERE APPLICABLE) STANDARDS, SPECIFICATIONS, AND DETAILS. HORIZONTAL DATUM: NAD83 VERTICAL DATUM: NGVD29 SEE SHEET C-3 FOR ALL PROJECT, SITE, GRADING, STORM DRAINAGE AND UTILITY NOTES. FES -100 CB -103 INV=341.00 T/C=354.38 JB -101 INV IN=350.30 (CB -104) �� RIM=350.10 �INV OUT=350.20 INV IN=346.55 (DI -105) CB -104 INV IN=346.55 (CB -102) T/C=355.04 INV OUT=346.30 INV OUT=350.90 CB -102 DI -105 T/C=351.80 T/G=352.20 INV IN=347.65 (CB -102A) INV OUT=348.70 INV IN=347.70 (CB -103) INV OUT=347.60 CB_ 102A T/C=351.80 \ -= INV OUT=347.70 CB -202 CB -212 T/C=328.80 T/C=357.46 INV IN=324.00 (CB -202A) INV OUT=353.40 INV IN=324.00 (CB -203) INV OUT=323.90 CB -213 _= T C=355.42 i T/C328.80 INV IN=349.30 (CB -214) INV OUT=324.10 INV OUT=349.20 ) CB -203 CB -214 /T/C=331.60 T/C=354,25 it j P" ,. INV IN=326.80 (CB -204) INV IN=350.00 (CB -215) 4,1 INV OUT=326.70 INV OUT=349.90 CB -204 CB -215 T/C=354.25 T/C=339.83 NV OUT=350.20 ! " INV IN=335.00 (CB -205) INV OUT=334.90 DI -216 " CB -205 T/G=352.50 ' T/C=345.16 INV OUT=349.00 - INV IN=337.90CB-217 ( ) CB -217 ! INV ►N=340.30 (CB -206) T/C=345.15 ! INV OUT=337.40 INV IN=338.20 (CB-218) CB-206 INV OUT=338.10 ! / T/C=350.49 CB -218 INV IN=345.40 (CB -207) T/C=343.02 / 1 % INV OUT=345.30 INV IN=338.70 (CB -222) INV IN=338.90 (CB -219) CB -207 INV OUT=338.60 T/C=350.49 INV IN=346.35 (DI -216) CB -219 INV IN=346.10 (CB -208) T/C=345.03 INV OUT=345.60 INV IN=340.90 (CB -220) INV OUT=340.80 CB -208 T/C=354.79 CB -220 INV IN=348.90 (CB -213) T/C=347.01 INV IN=350.70 (CB -209) INV IN=342.70 (CB -221) INV OUT=348.65 INV OUT=342.60 CB -209 CB -221 T/C=357.46 T/C=347.01 INV IN=353.20 (CB -212) INV OUT=342.90 INV IN=353.40 (CB -210) iNV OUT=353.10 CB -222 T/C=343.02 CB -210 INV OUT=338.90 � T/C=361.48 INV IN=357.40 (CB -211) " INV OUT=357.30 -; CB -211 T/C=362.09 INV OUT=358.00 It EW -300 CB -304 INV=344.50 T/C=359.11 .l CB -301 INV OUT=355.05 >> T/C=357.82 CB -305 INV IN=353.55 (CB -302) T/C=361.39 INV IN=353.50 (CB -303) INV IN=356.80-306 CB INV OUT=348.90 INV OUT=356.71? ) CB -302 T/C=357.82 CB -306 INV OUT=353.75 T/C=361.39 INV CB -303 INV OUT=357 05 CB -307) T/C=359.11 INV IN=354.85 (CB -304) CB -307 INV IN=354.70 (CB -303A) T/C=365.00 INV OUT=354.60 INV iN=360.90 (CB -308) i INV OUT=360.80 K'1\ CB -303A T/C=360.33 CB -308 INV IN=356.00 (CB -305) T/C=366.97 INV OUT=355.90 INV OUT=362.90 \� X G�EENtAY ` \��, `�AAl 6 EASEMENT \ t, V FINAL DRAWING - RELEASED FOR CONSTRUCTION M b MV ego to 0 2z i N J\ f� CAR SS fl 0 qA/ G.CID •. O H a Q aQ w Z z 0 Q a ___4 �✓ H w Q C) E-4 a ►-a aO0w o C\2 V VJ �4 R. 0 0 Cq W V A 1 O M� Q Z w a�¢ W V �9 �J V PROJECT NO. . JPM-15010 FIuNAME: JPM15010-G1 DESIGNED BY: N D W DRAWN BY: DLP SCALE: 1" = 50' DATE' 04-04-2016 SHEET N0. C-7 1111 MCADAMS UTILITY LEGEND Public Public Sewer Collection / Extension System Water Distribution / Extension System The city of Raleigh consents to the connection and extension of the The city of Raleigh consents to the connection and extension of the Citys public sewer system as shown on this plan. The material and City's public water system as shown on this plan. The material and Construction methods used for this project shall conform to the Construction methods used for this project shall conform to the standards and specifications of the City's Public Utilities Handbook. standards and specifications of the CitVs Public Utilities Handbook. City of Raleigh 402- City of Raleigh Public Utilities Department Permit B Public Utilities Department Permit # Authorization to Construct Authorization to Construct, Date 1511 (/t Date 'Sh 1/( l3 ool / S i X /� / 101, —25' STR T—T—T—T— TELEPHONE (2) 12-xOSS OSS WITH / / BUFFER EEf YARD TREE SAVE �) • SEWER CLEAN-OUT(2) 8- Gv&B / / (TYP.) EASEMENT LINE / WAKE. -' e t r f� 4G4 i 20' TOWN OF WAK l t REMOVE EX. 8- BLOW -OFF // i FOREST GREENWAY ® GREASE TRAP ASSEMBLY AND EXTEND 8.P �/ 3/4- TYPE -K- COPPER EASEMENT _e DIP W/L/ DOMESTIC WATER SERVICE WITH SEWER FLOW DIRECTION / 5/8" WATER METER (TVP.) �- ARROW / Y / �� -^-_ _ _ ---_- _ _ _ 467 1 % t ,v.:" \ f' C j ;:. / ^- - 45' BEND " 1 F / M SAWCUT, REMOVE, AND PATCH EXISTING ASPHALT AS REQUIRED FOR EX. FIRE HYDRANT i _ _ _ _ _ _ i �' / SM a -- g 12-x12- TAPPING SLEEVE WITH s �^ i / �� ASSEMBLY (TYP.) - t 4 SANITARY SEWER 1 12 Gv&e 4634 ice( �> as SERVICE WITH V. {�1 / ` CLEANOUT (TVP.) — 4p� 468 777 20' PRIVATE STORM t DRAINAGE EASEMENT SSMH-210 , ../ (TYP,) a 12- DIP 462 G(}LDFIN�I-I NEST COtTR�w __. — ME GROVE 0 �.., � .�� _ � �, , � _P , �� , �- MEADOW ROE R VE 50' PUBLIC R i P LIC R��� ` + SSMH-208 469 SEES ET P-4 Q - - -- - - `" SESHEET P- 3/4- TYPE -K- COPPER' EX. 20' SANITARY / DOMESTIC WATER !� SEWER EASEMENT SERVICE WITH 5/8 i z 10 (B.M. 2009 PG. 172) I WATER METER (TYP.) EX. FIRE HYDRANT_� �-- 25 459 ( 460 ASSEMBLY (TVP.) STREET , q% _---- YARD BUFFER ' 456 Q i EXISTING CITY OF RALEIGH 30 ` O I 461 SANITARY SEWER EASEMENT 1 455 + 4- SANITARY SEWER+ ' SSMH-207 BM 1998 PG 1731 & 1730 + + SERVICE WITH CLEANOUT i 454 (m'') FIRE HYDRANT f 470 x jI SPARROWIHA� SSMH-304 ASSEMBLY (TYP.) FIRE HYDRANT i s FIRE HYDRANT i (50 PUBLIC RAW) i' � ASSEMBLY (TYP.) ' - ASSEMBLY (TYI + - SEES ET P-3` --- -- ' a r� a SS 0/F "6" + SEE SHEET P-5) ° 8 DIPWL i e • � � _2 452 _ �� 1 ""-�- NNMHFiRE HYDRANT -"-- - ------ - - SSMH-20 g SSMH-202 ASSEMBLY (TYP.).� r _. R� v 12-x8- TEE 45' BEND f i (2) 12- GV&B (1) 8- GV&B _ SSMH 20tT3 THESE PLANS HAVE BEEN APPROVED FOR CONSTRUCTION BY THE TOWN OF WAKE FOREST Enginee ing Pepartment I Date ublicPor Departmen Date fa e 1 Co �l Erosio c S- dingLe ro Date 1 Fire Pr7v ntion Date lAccessi �% ate t'z2o_ Date Date City of Raleigh Public Utilities Department Date ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH TOWN OF WAKE FOREST, CITY OF RALEIGH & NCDOT (WHERE APPLICABLE) STANDARDS, SPECIFICATIONS, AND DETAILS. HORIZONTAL DATUM: NAD83 VERTICAL DATUM: NGVD29 SEE SHEET C-3 FOR ALL PROJECT, SITE, GRADING, STO! DRAINAGE AND UTILITY NOTES. � 1 J-- FLOODWAY 1 J NEW 30' CITY OF RALEIGH SANITARY SEWER EASEMENT & TOWF GREENWAY EASEMENT M p QQ� • �N V M o M _8 r Cq hh O SO �J CA ti i 4 80 = U' qN G O W Q cn aA W W Z cfl owo� P4 E-4 Z Q Q '—' ►moi E' a a aw � � �o A � � �1 V VJhhA� LV 0 1 �o a Qz w Q PROJECT NO. JPM-15010 FILENAME: JPM15010-U1 DESIGNED BY: N D W DRAWN BY: DLP SCALE: 1$J = 50' DATE: 04-04-2016 SHEET N0. w u-8 M" MCADAMS FIRE HYDRANT ASSEMBLY T YARD LIGHTS FIRE DEPARTMENT CONNECTION (FDC) LIGHT POLE ® WATER METER N WATER VALVE POWER POLE N POST INDICATOR VALVE ti LINE BREAK SYMBOL VALVE IN MANHOLE WATERLINE METER & VAULT WATER SERVICE LINE Q BACKFLOW PREVENTER----------------- UTILITY SLEEVE REDUCER SANITARY SEWER u PLUG SEWER SERVICE LINE o-►♦— BLOW -OFF ASSEMBLY—G—G—G—G— GAS LINE 01.1-01.1— OVERHEAD UTILITY SANITARY SEWER MANHOLE UE UE UNDERGROUND ELECTRIC Public Public Sewer Collection / Extension System Water Distribution / Extension System The city of Raleigh consents to the connection and extension of the The city of Raleigh consents to the connection and extension of the Citys public sewer system as shown on this plan. The material and City's public water system as shown on this plan. The material and Construction methods used for this project shall conform to the Construction methods used for this project shall conform to the standards and specifications of the City's Public Utilities Handbook. standards and specifications of the CitVs Public Utilities Handbook. City of Raleigh 402- City of Raleigh Public Utilities Department Permit B Public Utilities Department Permit # Authorization to Construct Authorization to Construct, Date 1511 (/t Date 'Sh 1/( l3 ool / S i X /� / 101, —25' STR T—T—T—T— TELEPHONE (2) 12-xOSS OSS WITH / / BUFFER EEf YARD TREE SAVE �) • SEWER CLEAN-OUT(2) 8- Gv&B / / (TYP.) EASEMENT LINE / WAKE. -' e t r f� 4G4 i 20' TOWN OF WAK l t REMOVE EX. 8- BLOW -OFF // i FOREST GREENWAY ® GREASE TRAP ASSEMBLY AND EXTEND 8.P �/ 3/4- TYPE -K- COPPER EASEMENT _e DIP W/L/ DOMESTIC WATER SERVICE WITH SEWER FLOW DIRECTION / 5/8" WATER METER (TVP.) �- ARROW / Y / �� -^-_ _ _ ---_- _ _ _ 467 1 % t ,v.:" \ f' C j ;:. / ^- - 45' BEND " 1 F / M SAWCUT, REMOVE, AND PATCH EXISTING ASPHALT AS REQUIRED FOR EX. FIRE HYDRANT i _ _ _ _ _ _ i �' / SM a -- g 12-x12- TAPPING SLEEVE WITH s �^ i / �� ASSEMBLY (TYP.) - t 4 SANITARY SEWER 1 12 Gv&e 4634 ice( �> as SERVICE WITH V. {�1 / ` CLEANOUT (TVP.) — 4p� 468 777 20' PRIVATE STORM t DRAINAGE EASEMENT SSMH-210 , ../ (TYP,) a 12- DIP 462 G(}LDFIN�I-I NEST COtTR�w __. — ME GROVE 0 �.., � .�� _ � �, , � _P , �� , �- MEADOW ROE R VE 50' PUBLIC R i P LIC R��� ` + SSMH-208 469 SEES ET P-4 Q - - -- - - `" SESHEET P- 3/4- TYPE -K- COPPER' EX. 20' SANITARY / DOMESTIC WATER !� SEWER EASEMENT SERVICE WITH 5/8 i z 10 (B.M. 2009 PG. 172) I WATER METER (TYP.) EX. FIRE HYDRANT_� �-- 25 459 ( 460 ASSEMBLY (TVP.) STREET , q% _---- YARD BUFFER ' 456 Q i EXISTING CITY OF RALEIGH 30 ` O I 461 SANITARY SEWER EASEMENT 1 455 + 4- SANITARY SEWER+ ' SSMH-207 BM 1998 PG 1731 & 1730 + + SERVICE WITH CLEANOUT i 454 (m'') FIRE HYDRANT f 470 x jI SPARROWIHA� SSMH-304 ASSEMBLY (TYP.) FIRE HYDRANT i s FIRE HYDRANT i (50 PUBLIC RAW) i' � ASSEMBLY (TYP.) ' - ASSEMBLY (TYI + - SEES ET P-3` --- -- ' a r� a SS 0/F "6" + SEE SHEET P-5) ° 8 DIPWL i e • � � _2 452 _ �� 1 ""-�- NNMHFiRE HYDRANT -"-- - ------ - - SSMH-20 g SSMH-202 ASSEMBLY (TYP.).� r _. R� v 12-x8- TEE 45' BEND f i (2) 12- GV&B (1) 8- GV&B _ SSMH 20tT3 THESE PLANS HAVE BEEN APPROVED FOR CONSTRUCTION BY THE TOWN OF WAKE FOREST Enginee ing Pepartment I Date ublicPor Departmen Date fa e 1 Co �l Erosio c S- dingLe ro Date 1 Fire Pr7v ntion Date lAccessi �% ate t'z2o_ Date Date City of Raleigh Public Utilities Department Date ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH TOWN OF WAKE FOREST, CITY OF RALEIGH & NCDOT (WHERE APPLICABLE) STANDARDS, SPECIFICATIONS, AND DETAILS. HORIZONTAL DATUM: NAD83 VERTICAL DATUM: NGVD29 SEE SHEET C-3 FOR ALL PROJECT, SITE, GRADING, STO! DRAINAGE AND UTILITY NOTES. � 1 J-- FLOODWAY 1 J NEW 30' CITY OF RALEIGH SANITARY SEWER EASEMENT & TOWF GREENWAY EASEMENT M p QQ� • �N V M o M _8 r Cq hh O SO �J CA ti i 4 80 = U' qN G O W Q cn aA W W Z cfl owo� P4 E-4 Z Q Q '—' ►moi E' a a aw � � �o A � � �1 V VJhhA� LV 0 1 �o a Qz w Q PROJECT NO. JPM-15010 FILENAME: JPM15010-U1 DESIGNED BY: N D W DRAWN BY: DLP SCALE: 1$J = 50' DATE: 04-04-2016 SHEET N0. w u-8 M" MCADAMS PLANT SCHEDULE (STREET TREES ONLY) LANDSCAPE CALCULATIONS SPECIMEN TREE REPLACEMENT SCHEDULE: EXISTING TREE LEGEND TREES CODE QTY COMMON NAME BOTANICAL NAME CALREMARKS STREET TREES TOTAL INCHES OF SPECIMEN TREES REMOVED: 281 CALIPER INCHES (SIZE IN INCHES) THESE PLANS HAVE BEEN APPROVED FOR CONSTRUCTION BY THE , REPLACEMENT RATE: 3 CALIPER INCHES REQUIRED PER 8 CALIPER INCHES REMOVED OTP TULIP POPLAR TOWN OF WAKE FOREST TRADITIONS RIDGE ROAD: 970 LF REQUIRED: 36 3 TREES OR 108 TOTAL CALIPER INCHES (281' REMOVED/ 8") • GA 14 Maidenhair Tree Ginkgo biloba 'Autumn Gold` TM 2" Male Species Only. CANOPY TREES REQUIRED: 20 (1/50 LF) PROVIDED: 37 3" TREES — 111 ADDITIONAL CALIPER INCHES OWIG *00000041 CANOPY TREES PROVIDED: 22 H HICKORY ' ' • QA 37 White Oak Quercus alba 3" HYDRANGEA FIELD COURT: 940 LF CANOPY TREES REQUIRED: 19 (1/50 LF) OEngeerg Department Date Q OAK — A6 CANOPY TREES PROVIDED: 20 O Public W s Departmen Date • QB 20 Swamp White Oak Quercus bicolor 2" g BEECH SPARROWHAWK LANE: 1,738 LF �. CANOPY TREES REQUIRED: 35 (1/50 LF) _ _ Ero i & Sediment Control Date �- QM 13 Burr Oak Quercus macrocar a 3' ` CANOPY TREES PROVIDED: 36 / - "' `"`=� GOLDENFINCH NEST COURT: 600 LF / / - / / /"` =� X� ?� Y l!�. �� Fire Pr n 'on Date UP 6 Chinese Elm Ulmus parvifolia 2" CANOPY TREES REQUIRED: 12 (1/50 LF) III i A - City of Raleigh Public Utilities Department Date Date Date Date 1 t LANDSCAPE CALCULATIONS *BUFFER CALCULATIONS ROYAL MILL AVENUE — STREET YARD BUFFER 771 LF TREES REQUIRED: 16 (2/ 100 LF) TREES PROVIDED: TBD POWER POLE UNDERSTORY TREES REQUIRED: 22 (1/ 35 LF) •�i®��®��®��®iio UNDERSTORY TREES PROVIDED: TBD PROPERTY LINE — — — RIGHT—OF—WAY LINE — — — — LOT LINE — — EASEMENT LINE 5' TYPE 'B' BUFFER 500 LF TREES REQUIRED: 5 (1/ 100 LF) 1 TREES PROVIDED: TBD UNDERSTORY TREES REQUIRED: 3 (.5/ 100 LF) UNDERSTORY TREES PROVIDED: TBD SHRUBS REQUIRED: 35 (7/ 100 LF) SHRUBS PROVIDED: TBD *SEE SHEET LS -2 FOR TYPICAL 100' LANDSCAPE BUFFER SECTIONS. FAS (ACCESS TEYMPE.N) T OF RALEIGH Ii 2�o ANITARY SEWER 'f 0' CITY EASEMENT 5' AR SETBACK ,.,. , x �► r� j\o ;�� � qj / s __-_/ �✓ Q7 i' t� �ai m <v a .o► ` • f .. . ' > , ' �` >��� iit. � ,' ,; �"„ -: " " ,....,,_ Qom(' "^'...,..._ •...<,,, r ..-t.-...._. I .n al cn 1.0 Q7 1 . , \ (B.M. 1999, PG I" j 803}-? NOTES: 1) ANY TREE LOCATED WITHIN A SIGHT DISTANCE TRIANGLE WILL BE LIMBED UP TO A MINIMUM OF 8'. 2) NO STREET LIGHTING SHALL BE LOCATED CLOSER THAN 15' FROM A STREET TREE. 3) NO STREET TREE SHALL BE CLOSER THAN 30' FROM ANOTHER STREET TREE MEASURED FROM TRUNK TO TRUNK. SITE LEGEND —n— 2 I I! t v - � SIGNAGE YARD LIGHTS LIGHT POLE POWER POLE TRAFFIC DIRECTIONAL ARROW •�i®��®��®��®iio PHASE LINE — — PROPERTY LINE — — — RIGHT—OF—WAY LINE — — — — LOT LINE — — EASEMENT LINE — CENTERLINE CONCRETE GRAPHIC SCALE 50 0 25 50 100 1 inch = 50 ft. FINAL DRAWING - RELEASED FOR CONSTRUCTION M p U �C4 M 0 z CID 0p ,7 U � _ I V N0) � HHH � o �J `11�i1111 Ul// — 80 y,. B.O W QCY, a Q E-4 W (110 z owo� > W F+ a <C o Vf V 0 ocqm a 1 W WO w r V PROJECT NO. JP M -1501 0 FNM: JPM15010-LS1 DESIGNED BY: N D W DRAWN BY: DLP SCALE: 1 " = 50' DATE: 04-04-2016 SHEET N0. LS -1 °Ji MCA.DAMMS 2. b -o .,,°s,�' w' f wig fc-1 two, o , d4 al �O5 tvw : as §t ' move emit 1" ushg wow to so _J STANDARD TREE INSTALLATION DETAIL (TYP I IN C 0RRI.0 C"(J 11 1 _SECT CUT a tl Y r � k 4 �HW MAX -Ml ou-MOV. OF 'sl Cr _ R f , •T ,r H A E P s � 'x'3e.zlS i3t?,,�u a > Cs3f N.T.S. STANDARD TTREE PRUNING DETAIL (TYP.) N.T.S. k'z PRO 'I __...._..,__.....____.;._-__r.:________-_..,...__-......__-____._...__-..____.-------- 53 ___.-__5 'ECT __ R " t PI , Y E 'TMENT 'PEE I IT - INE I,I NE a „ covering � ..__....e_ Iia OPERTY INE edge of rootball,. notpiled on 0 t g -a 5 i z r . LA AT4 AREA 6 PREFFERED FOR MEDUM WED TREES MIN, ( '- t ' T y ; �OR LA, hLE O at R: w , 6 R1 KK . �• r k „ CI In6��� SIZED TREES (45 °t 3 h w ; a, m a f' Iy L(�z­3above Tl EE . r tel fT E.E I`�S LAWN � �iEA X v s R& iAf BE DON 'I �T CARR C� ,IIrIalaT kzt F IIo back -fill S I 1 L a ; r L a ° M AREASt .i ' t� P€�CFUEt>TREE 1s. I SETWEDN STREET _ _ M SEN-. SMALL BE NO CLOSER THAN 5' TO DRIT4'KAYS #RFF ._ STANDARD TREE INSTALLATION DETAIL (TYP.) r1I-- -- N.T.S.' `F1f # LtO "STYt � e TRe tA31f�1Cm 4T ari PLANT T S ES 5' eOWNG SIODWA, K RIC HT-OF-y;AY UNE u 3 # f'ROPERITY INE 1 is ra,'i ort )€ ?Iw•§'�},#.Pa:. L iD GTaiT IES INL AI ARE�L.�.iti LA:*N AREA PUBLIC SIRE T l TRECS S41AL& r�E NO s L '4EF Tti,�,i 5' TO AT��S' PaV!E?,{ENl` OPTION IN €tsF� r tit Els aar SiR �.T EE iT w� J ,ILiT`Y EASEMENTF PRIVATE PCif rY' .^� �a4 Ri101,4T`-t --W Y LINE root PF:CfIERT"Y LINE R,.' �Bh i T E T TREES ball '`W 3 - - c 5` 8CMIND CURL,, A 6' PUBLIC xTR ET TREE EASEMENT MAY EtE , t;ii E.3 I" ttaAL �aL�A rRj800, SiREk" "s- - 1 TRAN 5' TO ORh E WAYS " TICN A STIR EET WIT8 SIDEWALK STANDARD TREE STAKING DETAIL (TYP.) N.T.S. STREET T EES SHALL CIE PLANTED IN THE flItH(---OF-6NAY 'WHEN ADE.O_t E SPAQE IS RI-11,10EL?. STREET TREES ARE TO DE PLAN'FEa IN A i PtJSUCt , STREET TREE EA MEEKT IN ALL OTHER SI tI AT:r t'i . STANDARD STREET TREE LOCATION DETAIL (TYP.) N.T.S. 4 V NEV IRKL 1-11111i € 1 I ; }illaT l' ,ice CALTA PLE STANDARD TTREE OVERHEAD UTILITIES DETAIL (TYP.) N.T.S. Drip Life eV € Critical Root Zom Exten& out frt m the trunk W the drip links. or to ,a distance of 1& per inch of VML w`ixicbever is ;greater Fur Rcat Zama Fxfa)& apt 2 to 3 dries beyond ft QiHW W Zone STANDARD CRITICAL ROOT ZONE DETAIL (TYPA N.T.S. t Fug r i S { a P Y rim ` k 'a € { r e Y. :✓, *€ � Iw,1 S x ka �* ^�' ), y si �` , i 'a `s�; a3' v F i l o . v €� _7171_77 4 V NEV IRKL 1-11111i € 1 I ; }illaT l' ,ice CALTA PLE STANDARD TTREE OVERHEAD UTILITIES DETAIL (TYP.) N.T.S. Drip Life eV € Critical Root Zom Exten& out frt m the trunk W the drip links. or to ,a distance of 1& per inch of VML w`ixicbever is ;greater Fur Rcat Zama Fxfa)& apt 2 to 3 dries beyond ft QiHW W Zone STANDARD CRITICAL ROOT ZONE DETAIL (TYPA N.T.S. t Fug r i S { a P Y rim ` k 'a € { r e Y. :✓, *€ � Iw,1 S x ka �* ^�' ), y si �` , i 'a `s�; a3' v 73 zf ' '_' TRE I ... �a 4 i k A,iz, i T baa-.,:7:s,Em:i: , .,.,•, ';t y c .� ..''� :_'�' ::�' ^a,., :a '3' :r'.. 4.,. .. , ,-` Yn,s" ,... � �.,�. �.�,.;-,. a T a Te ,JmE a s' r:,wi;, ;,Ip aim 4<L ppvj r , t 'COw �`;^,: i STANDARD TREE PROTECTION DETAIL (_TYP.) N.T.S. PLANT SCHEDULE (5' TYPE B BUFFER) PER EVERY 100' Lco 'NO 7 ^aB'_ x" A N t TREES CODE 01Y COMMON NAME BOTANICAL NAME CAL AA 1 Downy Serviceberry Amelanchier arborea 'Autumn Brilliance' 1.5" 8' UQA 1 White Oak Quercus alba 2" 10' SHRUBSOC DE OTY COMMON NAME BOTANICAL NAME IMC QQ, 0 IC 1 Carolina #2 American Holly Ilex opaca `Carolina #2' 6- 0 MC 3 Wax Myrtle Myrica cenfera 36- 0 OF 3 Sweet Olive Osmanthus fragrans 36" 5' TYPE B BUFFER DETAIL (TYP.), N.T.S. PLANT SCHEDULE (25' STREET YARD) PER EVERY 100' TREES CQDE M COMMON NAME BOTANICAL NAME CAL HE REMARKS 0 AA 2 Downy Serviceberry Amelonchier orborea 'Autumn Brilliance' 1.5' 8' CK 1 Kouso Dogwood Cornus kousa 1.5' 8' QB 2 Swamp White Oak Quercus bicolor 3' 25' STREET YARD BUFFER DETAIL (TYP.) N.T.S. SEE SHEET C-2 FOR ALL PROJECT, SITE, GRADING, STORM DRAINAGE AND UTILITY NOTES ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH TOWN OF WAKE FOREST, CITY OF RALEIGH & NCDOT (WHERE APPLICABLE) STANDARDS, SPECIFICATIONS, AND DETAILS. LANDSCAPE NOTES: 1. ALL MATERIALS AND METHODS OF CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE TOWN OF WAKE FOREST AND THE STATE OF NORTH CAROLINA STANDARDS AND SPECIFICATIONS. 2. THE LOCATION OF ALL EXISTING UTILITIES SHOULD BE CONFIRMED PRIOR TO BEGINNING CONSTRUCTION. CALL "NC ONE -CALL", 1-800-632-4949. NOTIFY OWNER OF ANY DISCREPANCIES BETWEEN FIELD CONDITIONS AND THOSE SHOWN ON THE PLAN. 3, ALL PLANT MATERIALS TO COMPLY WITH THE MOST CURRENT VERSION OF THE AMERICAN STANDARDS FOR NURSERY STOCK Z60.1-2014. http://americanhort.org/documents/ANSI-N ursery-Stock-Standords-AmeericanHort-2014. pdf 4. LOCATE ALL EXISTING UTILITIES PRIOR TO INSTALLATION OF PLANT MATERIAL. NOTIFY OWNER OF ANY DISCREPANCIES BETWEEN FIELD CONDITIONS AND THOSE SHOWN ON THE PLAN. 5. ANY TREE LOCATED WITHIN A SIGHT DISTANCE TRIANGLE WILL NEED TO BE LIMBED UP TO A MINIMUM OF 8 FEET. 6. VERIFICATION OF TOTAL QUANTITIES AS SHOWN ON THE PLANT LIST SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. 7. SUBSTITUTIONS OF SPECIFIC PLANTS CAN ONLY OCCUR WITH PRIOR WRITTEN PERMISSION OF BOTH OWNER AND LANDSCAPE ARCHITECT. 8. ALL TREE PLANTINGS SHALL BE MULCHED WITH 3 INCHES OF SHREDDED BARK OR 4 INCHES OF PINE STRAW IN A 3 FOOT RADIUS AROUND THE TREE, OR TO THE DRIPLINE, WHICHEVER IS GREATER. THE MULCH SHALL BE FREE OF TRASH AND MAINTAINED WEED FREE THEREAFTER. MULCH SHALL NOT COVER THE ROOT COLLAR. 9. ALL TREES MUST BE PLANTED AFTER OCTOBER 1 AND BEFORE MARCH 31. 10. AT THE TIME OF PLANTING, CANOPY TREES MUST HAVE A MINIMUM CALIPER OF 1,5 INCHES AS MEASURED AT 6 INCHES ABOVE GRADE. MULTI -STEMMED TREES SHALL HAVE AT LEAST 3 STALKS AND MUST BE AT LEAST 6 FEET IN HEIGHT WHEN PLANTED. 11. STAKING SHALL BE REQUIRED WHERE PLANTS ARE UNABLE TO SUPPORT THEMSELVES WITH THEIR EXISTING ROOT SYSTEM. SUCH CONDITIONS MAY INCLUDE BARE ROOTED PLANTS, STRONG WIND SITUATIONS, LOOSE SOIL, WET CONDITIONS, STEEP SLOPES. TREE TIES SHALL BE SOFT, MIN 1 INCH WIDE POLYMER MATERIAL. NO KNOTS ARE TO BE TIED AROUND THE TRUNK THAT MAY RESTRICT GROWTH. TIES ARE TO BE REMOVED AFTER ONE YEAR FOLLOWING INSTALLATION. 12. NO TREES SHALL BE PLANTED WITHIN 15' OF ANY LIGHT POLE. INSTALLATION NOTES: 1. IF ANY TREES DIE DUE TO CONSTRUCTION ON SITE THEY SHALL BE REPLACED AT THE CONTRACTOR'S EXPENSE IN ACCORDANCE WITH LOCAL ZONING ORDINANCES AND WITH APPROVAL OF THE OWNER AND / OR LANDSCAPE ARCHITECT. 2. ALL TREES AND SHRUBS SHALL BE GUARANTEED TO BE HEALTHY AND TO SURVIVE THE FIRST YEAR AT JOB SITE. 3. ALL TREES SHALL BE CERTIFIED NURSERY GROWN: BURLAP AND BALL (B&B) OR CONTAINER.SCARIFY AND UNTWIST ANY CIRCLING OR GIRDLING ROOTS FOUND IN CONTAINER GROWN PLANTS. 4. REMOVE ALL TREATED OR PLASTIC -COATED BURLAP, STRAPPING WIRE OR NYLON TWINE FROM ROOT BALL. AFTER SETTING IN HOLE,CUT AWAY TOP AND SIDES OF WIRE BASKET. 5. INSTALL TREES SO THAT THE ROOT COLLAR IS AT GRADE OR ONE INCH ABOVE EXISTING GRADE. IF ROOT COLLAR IS NOT VISIBLE, REMOVE SOIL FROM TOP OF ROOT BALL TO EXPOSE ROOT COLLAR. 6. SEr ALL PLANTS IN VERTICAL POSITION PRIOR TO STAKING. 7. SOAK PLANT BALL AND PIT IMMEDIATELY AFTER INSTALLATION. 8. ALL PRUNING SHALL CONFORM TO THE METHODS SET FORTH IN THE CURRENT EDITION OF THE TREE, SHRUB, AND OTHER WOODY PLANT MAINTENANCE - STANDARD PRACTICES OF THE AMERICAN NATIONAL STANDARDS INSTITUTE AND TOWN OFFICIALS. 9. ALL PLANTS MUST BE INSTALLED ACCORDING TO THE MOST RECENT LOCAL APPLICABLE CODES AND ORDINANCES. 8.9.2 MAINTENANCE Its be the responsibility of the property owners) or assigned caretakers to ensure that all regulated landscaped areas, buffers, fencing, and tree save areas are. installed, preserved, and maintained in good growing conditions, appearance, and usefulness. Damage and disturbances to these areas shall result in vegetation replacement and/or fines and other penalties. Preservation and maintenance shall include: A. Any dead, unhealthy, or missing vegetation, shall be replaced with vegetation that conforms to the standards of this section and the approved site and/or subdivision plan. B. All required buffers, streetyards, vehicular use areas, tree save areas and other landscaped areas shall be free of refuse and debris, shall be treated for pest/diseases in accordance with the approved site and/or subdivision plan, and shall be maintained as to prevent mulch, straw, dirt, or other materials from washing onto streets and sidewalks. C. The owner(s) shall take actions to protect all plant material from damage during all facility and site maintenance operations. All plant material must be maintained in a way that does not obstruct sight distances at roadways and intersections, obstruct traffic signs or devices, and interfere with the use of sidewalks or pedestrian trails_ Plant material, whether located within buffers, tree save areas, or within phanted areas (regtured by the site and/or subdivision plan) shall not be removed, damaged, cut or severely pruned so that their untended form is impaired. Shrubs within vehicular use areas, streetyards, and street fronts may be pruned, but must maintain at least 3 feet u1 height, D. In the event that existing required vegetation located within any buffers, tree save areas, streetyards, vehicular use or other landscape areas poses an immediate or imminent threat to improved structures on private property or public property, excessive pruning or removal of the vegetation may be allowable provided authorization is obtained from the Administrator, and the performance standard of the landscape area is maintained consistent with this section. Replacement vegetation may be required as a condition of the permit. E. In the event that any vegetation or physical element functioning to meet the standards of this section is severely damaged due to an unusual weather occurrence or natural catastrophe, or other natural occurrence, the owner may be required to replant if the requirements of the section are not being met. Replacement vegetation shall conform to the standards of this section and the approved site and/or subdivision plan. THESE PLANS HAVE BEEN APPROVED FOR CONSTRUCTION BY THE TOWN OF TAKE FOREST ks d Eng' eeri g Dep rtment /bate ! l L F Public ks Department Date Erosion (N�&J(�{{Sediment Control Date ,& 7V Date at� g l Date 911& Date N[A City of Raleigh Public Utilities Department Date FINAL DRAWING - RELEASED FOR CONSTRUCTION M �NC> MU U o a w � V toO ■+ Z ® 04Z if3 1 p U 8 C4 h O�0 VJ A,, , Q •1. gp • ,� _ i Q z O ►-4 Cn � Q aQ a� W ZLO �--t C) 1`-"-'I ww�MM� Q � W � � H E'' a a co A a � fV i V 0 � � W 0 0z t� w Vr� Vl PROJECT No. JPM-15010 FH.ENAmE: JPM15010-LS1 DESIGNED BY: N D W DRAWN BY: DLP SCALE: 1 " = 50' DATE: 04-04-2016 SHEET NO. L-2 r MCADAMs i l _7171_77 73 zf ' '_' TRE I ... �a 4 i k A,iz, i T baa-.,:7:s,Em:i: , .,.,•, ';t y c .� ..''� :_'�' ::�' ^a,., :a '3' :r'.. 4.,. .. , ,-` Yn,s" ,... � �.,�. �.�,.;-,. a T a Te ,JmE a s' r:,wi;, ;,Ip aim 4<L ppvj r , t 'COw �`;^,: i STANDARD TREE PROTECTION DETAIL (_TYP.) N.T.S. PLANT SCHEDULE (5' TYPE B BUFFER) PER EVERY 100' Lco 'NO 7 ^aB'_ x" A N t TREES CODE 01Y COMMON NAME BOTANICAL NAME CAL AA 1 Downy Serviceberry Amelanchier arborea 'Autumn Brilliance' 1.5" 8' UQA 1 White Oak Quercus alba 2" 10' SHRUBSOC DE OTY COMMON NAME BOTANICAL NAME IMC QQ, 0 IC 1 Carolina #2 American Holly Ilex opaca `Carolina #2' 6- 0 MC 3 Wax Myrtle Myrica cenfera 36- 0 OF 3 Sweet Olive Osmanthus fragrans 36" 5' TYPE B BUFFER DETAIL (TYP.), N.T.S. PLANT SCHEDULE (25' STREET YARD) PER EVERY 100' TREES CQDE M COMMON NAME BOTANICAL NAME CAL HE REMARKS 0 AA 2 Downy Serviceberry Amelonchier orborea 'Autumn Brilliance' 1.5' 8' CK 1 Kouso Dogwood Cornus kousa 1.5' 8' QB 2 Swamp White Oak Quercus bicolor 3' 25' STREET YARD BUFFER DETAIL (TYP.) N.T.S. SEE SHEET C-2 FOR ALL PROJECT, SITE, GRADING, STORM DRAINAGE AND UTILITY NOTES ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH TOWN OF WAKE FOREST, CITY OF RALEIGH & NCDOT (WHERE APPLICABLE) STANDARDS, SPECIFICATIONS, AND DETAILS. LANDSCAPE NOTES: 1. ALL MATERIALS AND METHODS OF CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE TOWN OF WAKE FOREST AND THE STATE OF NORTH CAROLINA STANDARDS AND SPECIFICATIONS. 2. THE LOCATION OF ALL EXISTING UTILITIES SHOULD BE CONFIRMED PRIOR TO BEGINNING CONSTRUCTION. CALL "NC ONE -CALL", 1-800-632-4949. NOTIFY OWNER OF ANY DISCREPANCIES BETWEEN FIELD CONDITIONS AND THOSE SHOWN ON THE PLAN. 3, ALL PLANT MATERIALS TO COMPLY WITH THE MOST CURRENT VERSION OF THE AMERICAN STANDARDS FOR NURSERY STOCK Z60.1-2014. http://americanhort.org/documents/ANSI-N ursery-Stock-Standords-AmeericanHort-2014. pdf 4. LOCATE ALL EXISTING UTILITIES PRIOR TO INSTALLATION OF PLANT MATERIAL. NOTIFY OWNER OF ANY DISCREPANCIES BETWEEN FIELD CONDITIONS AND THOSE SHOWN ON THE PLAN. 5. ANY TREE LOCATED WITHIN A SIGHT DISTANCE TRIANGLE WILL NEED TO BE LIMBED UP TO A MINIMUM OF 8 FEET. 6. VERIFICATION OF TOTAL QUANTITIES AS SHOWN ON THE PLANT LIST SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. 7. SUBSTITUTIONS OF SPECIFIC PLANTS CAN ONLY OCCUR WITH PRIOR WRITTEN PERMISSION OF BOTH OWNER AND LANDSCAPE ARCHITECT. 8. ALL TREE PLANTINGS SHALL BE MULCHED WITH 3 INCHES OF SHREDDED BARK OR 4 INCHES OF PINE STRAW IN A 3 FOOT RADIUS AROUND THE TREE, OR TO THE DRIPLINE, WHICHEVER IS GREATER. THE MULCH SHALL BE FREE OF TRASH AND MAINTAINED WEED FREE THEREAFTER. MULCH SHALL NOT COVER THE ROOT COLLAR. 9. ALL TREES MUST BE PLANTED AFTER OCTOBER 1 AND BEFORE MARCH 31. 10. AT THE TIME OF PLANTING, CANOPY TREES MUST HAVE A MINIMUM CALIPER OF 1,5 INCHES AS MEASURED AT 6 INCHES ABOVE GRADE. MULTI -STEMMED TREES SHALL HAVE AT LEAST 3 STALKS AND MUST BE AT LEAST 6 FEET IN HEIGHT WHEN PLANTED. 11. STAKING SHALL BE REQUIRED WHERE PLANTS ARE UNABLE TO SUPPORT THEMSELVES WITH THEIR EXISTING ROOT SYSTEM. SUCH CONDITIONS MAY INCLUDE BARE ROOTED PLANTS, STRONG WIND SITUATIONS, LOOSE SOIL, WET CONDITIONS, STEEP SLOPES. TREE TIES SHALL BE SOFT, MIN 1 INCH WIDE POLYMER MATERIAL. NO KNOTS ARE TO BE TIED AROUND THE TRUNK THAT MAY RESTRICT GROWTH. TIES ARE TO BE REMOVED AFTER ONE YEAR FOLLOWING INSTALLATION. 12. NO TREES SHALL BE PLANTED WITHIN 15' OF ANY LIGHT POLE. INSTALLATION NOTES: 1. IF ANY TREES DIE DUE TO CONSTRUCTION ON SITE THEY SHALL BE REPLACED AT THE CONTRACTOR'S EXPENSE IN ACCORDANCE WITH LOCAL ZONING ORDINANCES AND WITH APPROVAL OF THE OWNER AND / OR LANDSCAPE ARCHITECT. 2. ALL TREES AND SHRUBS SHALL BE GUARANTEED TO BE HEALTHY AND TO SURVIVE THE FIRST YEAR AT JOB SITE. 3. ALL TREES SHALL BE CERTIFIED NURSERY GROWN: BURLAP AND BALL (B&B) OR CONTAINER.SCARIFY AND UNTWIST ANY CIRCLING OR GIRDLING ROOTS FOUND IN CONTAINER GROWN PLANTS. 4. REMOVE ALL TREATED OR PLASTIC -COATED BURLAP, STRAPPING WIRE OR NYLON TWINE FROM ROOT BALL. AFTER SETTING IN HOLE,CUT AWAY TOP AND SIDES OF WIRE BASKET. 5. INSTALL TREES SO THAT THE ROOT COLLAR IS AT GRADE OR ONE INCH ABOVE EXISTING GRADE. IF ROOT COLLAR IS NOT VISIBLE, REMOVE SOIL FROM TOP OF ROOT BALL TO EXPOSE ROOT COLLAR. 6. SEr ALL PLANTS IN VERTICAL POSITION PRIOR TO STAKING. 7. SOAK PLANT BALL AND PIT IMMEDIATELY AFTER INSTALLATION. 8. ALL PRUNING SHALL CONFORM TO THE METHODS SET FORTH IN THE CURRENT EDITION OF THE TREE, SHRUB, AND OTHER WOODY PLANT MAINTENANCE - STANDARD PRACTICES OF THE AMERICAN NATIONAL STANDARDS INSTITUTE AND TOWN OFFICIALS. 9. ALL PLANTS MUST BE INSTALLED ACCORDING TO THE MOST RECENT LOCAL APPLICABLE CODES AND ORDINANCES. 8.9.2 MAINTENANCE Its be the responsibility of the property owners) or assigned caretakers to ensure that all regulated landscaped areas, buffers, fencing, and tree save areas are. installed, preserved, and maintained in good growing conditions, appearance, and usefulness. Damage and disturbances to these areas shall result in vegetation replacement and/or fines and other penalties. Preservation and maintenance shall include: A. Any dead, unhealthy, or missing vegetation, shall be replaced with vegetation that conforms to the standards of this section and the approved site and/or subdivision plan. B. All required buffers, streetyards, vehicular use areas, tree save areas and other landscaped areas shall be free of refuse and debris, shall be treated for pest/diseases in accordance with the approved site and/or subdivision plan, and shall be maintained as to prevent mulch, straw, dirt, or other materials from washing onto streets and sidewalks. C. The owner(s) shall take actions to protect all plant material from damage during all facility and site maintenance operations. All plant material must be maintained in a way that does not obstruct sight distances at roadways and intersections, obstruct traffic signs or devices, and interfere with the use of sidewalks or pedestrian trails_ Plant material, whether located within buffers, tree save areas, or within phanted areas (regtured by the site and/or subdivision plan) shall not be removed, damaged, cut or severely pruned so that their untended form is impaired. Shrubs within vehicular use areas, streetyards, and street fronts may be pruned, but must maintain at least 3 feet u1 height, D. In the event that existing required vegetation located within any buffers, tree save areas, streetyards, vehicular use or other landscape areas poses an immediate or imminent threat to improved structures on private property or public property, excessive pruning or removal of the vegetation may be allowable provided authorization is obtained from the Administrator, and the performance standard of the landscape area is maintained consistent with this section. Replacement vegetation may be required as a condition of the permit. E. In the event that any vegetation or physical element functioning to meet the standards of this section is severely damaged due to an unusual weather occurrence or natural catastrophe, or other natural occurrence, the owner may be required to replant if the requirements of the section are not being met. Replacement vegetation shall conform to the standards of this section and the approved site and/or subdivision plan. THESE PLANS HAVE BEEN APPROVED FOR CONSTRUCTION BY THE TOWN OF TAKE FOREST ks d Eng' eeri g Dep rtment /bate ! l L F Public ks Department Date Erosion (N�&J(�{{Sediment Control Date ,& 7V Date at� g l Date 911& Date N[A City of Raleigh Public Utilities Department Date FINAL DRAWING - RELEASED FOR CONSTRUCTION M �NC> MU U o a w � V toO ■+ Z ® 04Z if3 1 p U 8 C4 h O�0 VJ A,, , Q •1. gp • ,� _ i Q z O ►-4 Cn � Q aQ a� W ZLO �--t C) 1`-"-'I ww�MM� Q � W � � H E'' a a co A a � fV i V 0 � � W 0 0z t� w Vr� Vl PROJECT No. JPM-15010 FH.ENAmE: JPM15010-LS1 DESIGNED BY: N D W DRAWN BY: DLP SCALE: 1 " = 50' DATE: 04-04-2016 SHEET NO. L-2 r MCADAMs U Z CF 0 W E 0 0- Q N N m a a 0 to M a m i rn c 3 v n c 0 U 2 0 0 a c J 0 0 1 / U 0 GLTJV LJ't'VV 0- X � ► t 1 50' NEUSE RIPARIAN BUFFER (MEASURED 50' FROM TOP 1 OF BANK, EACH SIDE) / TREE SAVE (TYP.) N S. t EX. SSMH-301 / f w. 00 4 �g 63 , 0p 1QNAk4s� is f '0' REMOVE PHASE 2C 12" BLOW -OFF ASSEMBLY AND t N t / EXTEND 12' DIP W/L _ (UNDER CONSTRUCTION PERMITTED UNDER W-3368) / EX. 102 LF DUAL 72" / ALUMINUM PIPES @ 3.927./ INV. IN = 344.00' / INV. OUT = 340.00' / EX. 24'L x 22'W CLASS "B" RIP-RAP PLUNGE POOL (18/ LONG, 1.18' DEEP POOL) -7- -- XS EX. 30' CITY OF 1 ... - - + RALEIGH SANITARYi 1 I I' SEWER EASEMENT I i i EX. 20' SANITARY f 1 (TYP.) (B.M. 1999, SEWER EASEMENT 1 1 'PG. 803) FIRE HYDRANT (B.M. 2009, PG. 172) I ASSEMBLY (TYP.) 1 " " M 3/4 TYPE K COPPERt I DOMESTIC WATER i P.I. I STA. 28+08.89 TRADITION RID E ROAD = ' 448 SERVICE WITH 5/8" 104100.00 SPARROWHAWK LANE I 12"x8' TEE WATER METER (TYP.) (2) 12"GV&B f 12"x6*1 452 (1) 8' GV&B I TEE 449 1 , 451 (2) 12" GV&B 1 ' (1) 6" GV&B 4" SANITARY SEWER I STANDARD OURS AADGUTTERi I 453 1 SERVICE WITH TO 30" VALLEY CURB TYP. FIRE HYDRANT t CLEANOUT (TYP.) 1 (TYP.) ' 1 1 1ASSEMBLY (TYP.) P.i STA. 25+26.37 TRA ITIO S RIDGE ROAD = f 76 LF 15" RCP i 10+00.00 HYDRANGEA FIELD COURT 30" VALLEY i 0 2.64% i 1 CURB (TYP.) 5' CONCRETE I I � 1 ACCESSIBLE i ! SIDEWALK i RAMP (TYP.) i i TR IONS R if w ' IDG ROAD I a U _-- / 20'R - - - - _ _ 0 PUBLIC R GB �� 1 1 _ 32 LF 15 RCP •' .._ . ® 0.6 io 25+00 o 26+00 -"' IP 8' SS - N42' 1'33" 27+0 84S 28+00 a 5 9.54' c CB -305 32 LF 18" RCP < 10 ® 0.77% CB -303 30'R Lo in .30'R 01 1 20' 20'R - f' 108 LF 18" RCP 60'1 R/W _ - - - 20'R CORE DRILL & ®1,01% rn 35'1 B -B INSTALL FLEXIBLE ° t139 LF 15' RCP f RUBBER BOOT " v 46 LF 18" RCP t 64 LF 18 RCP !2 1 ® 2.52% 1 t 0 1.87% ® 1.51% I � EX. SSMH-302 r 30" STANDARD CURB I i 1 �- 45 LF 18" RCP i A AND GUTTER (TYP.) i I ® 9.82% I vlo CB -30 rn 484 1 ! � 25' B -e HYDRANGEA FIELD COUPT C 50' R/W i (50 1 LIC R/W) i SEE SHEET P-2 1 i SPARROWHAWK LATE 1 (50 PUBLIC RAW) SEE SHEET P--3 _300.00' 29+00 L=48.31' v - , 20'R ' v 20'R ACCESSIBLE RAMP (TYP.) 1 1 454 it 1 L- N�2 4fe 66.96' 1 , £ £� E SAWCUT, REMOVE, AND PATCH EXISTING ASPHALT AS REQUIRED FOR 12'02" TAPPING SLEEVE WITH (1) 12" GV&B z P.I. STA 29+79.35 TRADITIO CL ROYAL MILL AVENUE ? \ } TiE TO EXISTING 30" STANDARD CURB AND GUTTER AND EXISTING ASPHALT (TYP.) t €I 0 c9 ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■o■■■■■■■■■■■■■■■■■M.■■■■■■ r Z 't _r V V C4_*SuZvlvJ Lb+UU 2/+UU 28+00 29+00 30+00 30+50 CB -301 STA 23+73.90 T/C=357.82 INV IN=353.55 (CB -302) INV IN=353.50 (CB -303) INV OUT=348.90 CB -302 STA 23+73.90 T/C=357.82 INV OUT=353.75 CB -303 STA 24+82.37 T/C-359.11 INV iN=354.85 (CB -304) INV IN=354.70 (CB -303A) INV OUT=354.60 CB -304 STA 24+82.37 T/C=359.11 INV OUT=355.05 CB -305 STA 25+70.37 T/C-361.39 INV IN=356.80 (CB -306) INV OUT=356.70 CB -306 STA 25+70.37 T/C=361.39 INV IN=357.30 (CB -307) INV OUT=357.05 CB -307 STA 27+09.37 T/C=365.00 INV IN=360.90 (CB -308) INV OUT=360.80 CB -308 STA 27+85.20 T/C=366.97 INV OUT=362.90 GRAPHIC SCALE 40 0 20 40 80 1 inch = 40 ft. Public Sewer Collection / Extension System The city of Raleigh consents to the connection and extension of the City's public sewer system as shown on this pian. The material and Construction methods used for this project shall conform to the standards and specifications of the City's Public Utilities Handbook. City of Raleigh ( Z Public Utilities Department Permit # Authorization to Construct Date 'Siti CI Public Water Distribution / Extension ,System The city of Raleigh consents to the connection and extension of the Citys public water system as shown on this plan. The material and Construction methods used for this project shod conform to the standards and specifications of the City's Public Utilities Handbook. City of Raleigh W ?jQt o Public Utilities Department Permit # Authorization to Construct`^' Date S1 I t / C b ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH TOWN OF WAKE FOREST, CiTY OF RALEIGH & NCDOT (WHERE APPLICABLE) STANDARDS, SPECIFICATIONS, AND DETAILS. HORIZONTAL DATUM: NAD83 VERTICAL DATUM: NGVD29 THESE PLANS HAVE BEEN APPROVED FOR CONSTRUCTION BY THE TOWN OF WAKE FOREST 5 Engi eeri g Department Date f/�-�� /01 Public Works Department Date r- Ero 'on ediment on roi Date Qi_�> City of Raleigh Public Utilities Department Date Date r l , Date Date S't. Date FINAL DRAWING - RELEASED FOR CONSTRUCTION REVISIONS: OWNER.- PROJECT No. ���,,►►►►►��,,,.. JPM-15010 SiiEET N0. _1 � JPM SOUTH DEVELOPMENT, LLC ���� � �s ',, , FEs • ' - DESIGNEDI FILENAME: BY: JPM15010-P1 '7208 FALLS OF THE NEUSE RD NDW P FII' SUITE 1012905 Meridian Parkway - 46 0 - DRAIN BY: NDW P - 2DD"ham'J RALEIGH NC 27815, North Carolina 27713 LicenseNo.: C-0293 ��o ti ��;�,� xoRlz. scALE: MCADAMS 1 = 40 TMADMONS RIDGE ROAD, STA. 22+5® TgiRU STA. 30+50 CONSTRUCTION I� NGS G �;C)� ` VERT. SCALE: » > (800) 733-5646 MCAdamSC:O.001n1 �i��qT •••••• ••••'� ` 1 = 4 PRINT DATE: McADAms�''�•.q;; ► ► G. DATE: l� 04-04-2016 WAEE FOREST, ORM CAR.OLMA ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■o■■■■■■■■■■■■■■■■■M.■■■■■■ ■■.■■■■■■■■■■■■■■■�]?■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■mI■■■■■■■■■■■■■■■■■m1■■■■■■ ■■■■■■■■■■■■■■■■■iiiiii•Yii;mmi mmm■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■mI■■■■■■■■■■M■■■■■■O'■■■■■■ ■■M■■■■■■■■■M■■■■■� '=NMM■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■I■■M■M■■■■MM■■M■■■M1■M■��■ m■■■m■m■■m■m■■Imm■■■ •Igo■■■■■■■■m■m■■m■■■■■■■■■■m■m■■■■■■riM■■1■■■■■■■■■N- MEM- 11NIM■■■ME ■■m■■■m■■■■m■■■■mm■■m■■oil■■■■m■■m■■■■mm■m■M■■■M■■■■■■M■EI�■m-rm■■■■■mmmmmiI' imm ■■■■m■ ■■■mm■■m■■■■m■m■■m■m■■■■Im■■■■m■■■m■■■m■■■■m■■■■■m■■■■■■f�IMMmim■mm■■m■■mmmiaN1NE■■MM■■ mm■■■m■■■mm■■■mmm■■m■■■■Iii■■■■■■m■■■■■■■m■■■■m■■m■■■■■■■ I-a■!l■■■m■■■mm■ limpO■■M�■ m■■■mm■■m■■■■■■mm■■m■■■E-IMM■ ' :I■■■■■M■■■■■■■M■■■■M■M■■■■■■EIM■M1L3■m■■■■mmmm I■11013■■■MM ■■■■■■■■■■■■■■■■■■■■■■■aI■.■m'+,■■■■■■■■■■■■■■■■■■■■■■■■■■■®I-M■M,4in■■■■.•'ZE!RI: mm■■■m■ ■■■■■■m■■■■m■■■■■■■■■■■■I■■■EIMM■■■■■■■M■■■■■■EEMEME■■■E■EIo■■1■mm-mmdm■■■■■o■■■m■■■ ■■■■■■m■■■■■■■■■■■■■■■■■I■■■EIMM■■■■■■E'l■■■■■■■ .■■■■■■■■N1■■I■■' • I�m■■■■■■■■■■■m■■■■■■■ ■■m■■■11m■■■mm■■■■■m■■■■■I■■mgo■■■■■■m■mlr.immo■■■■■■■immm� ■l1p'.'i i90119112mmmmmN■m■mm■m■■■■■ a■■■■■■■■u■■■■■■■■I■■■m9■■■■mo■■MIM■■■■O■■ ■.■..•■''f'■■MMINIII1,10_0■•___ ■■■■■■■■ �i l ■��■��■��■�■■■����1■�■■■■■■1■■■��■■■■■�■■■��■�■■���a� I■■■■I■13�/_!!I_I/_�I�r,t�l�►��ll:®■■■�■�1�■■��I■f■■�■■�■ ■■■ ■■■■■■■■�� ■■■■■■I■■■� �■�N■■■R9 M-EMPOPMENEM111 ME01910000mi llt1 ®./■��■Till■�■■�■■�■■��I■■■�■■�� ■���1�■//■��`��ii■�����■�■■■1■■��I■.�1�:.■r■■■iII■ISI��!� ._..���■�■%/r/I.II■■■■■■■■■���11■Lt■■■■■■ . �■■X11%//■■■�■■■�®1■�■■�■���1■■�I/!�'.r■■II■■�■■tl_i!1.1�"' ���I� 'i'" ..,.�.��!■■■■■I���.�i/■/■1■■■■■■■■■�■■�1■1�■■■■li■ ., .u�%■�■■■II/i■ .,i _...-:.i%■■■■■�■/�i/.��■■■■1■�■�■■Ifi■■�■■���1■■�■■� _�■11/■/■��■■�®■�/l1■■■■■■I�! ���!X111//■1■■��■�■i����■i■r�'�lGr1■�■■Il��i�■��■�■Ill ilk! ®■�■�III■■■�■■/■�■�■■■■■■�■■■■I�i1i�s■!�1■■■■■■■�■■■�■■� ����nlr�.11�©_ ������■��■■�����!��■■■��■�■�t:��■�■Illi■■������■■■■�■■■■�■��■■�■■�■�■■■��■�■■■�■■ ����_�■IIr1�1��-.� �■I-I�■■■��®■■',� ll�llll_�®3111.,,/I,.■■■■■■■■■■■■■■��■■■■■■■■■■■■■■■■■■■■■ ■■�III� �.'��'. , ,■■.•ii. ® r1 �■■�_ �fj!',III■.■■■■■■■■■■■■■■■■■�■■■■■■■■■■■■■■■■■■■■■ ____ MMEMMEMEMMEMME �'�■■��■����■■III,■����■■■■���,��,.■■■■■■■'�■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■I■■M■■ME■U,��■■..i�,■■■■■■■■■■■■■'■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■���'■■■■.■■■■■■■■��■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ Z 't _r V V C4_*SuZvlvJ Lb+UU 2/+UU 28+00 29+00 30+00 30+50 CB -301 STA 23+73.90 T/C=357.82 INV IN=353.55 (CB -302) INV IN=353.50 (CB -303) INV OUT=348.90 CB -302 STA 23+73.90 T/C=357.82 INV OUT=353.75 CB -303 STA 24+82.37 T/C-359.11 INV iN=354.85 (CB -304) INV IN=354.70 (CB -303A) INV OUT=354.60 CB -304 STA 24+82.37 T/C=359.11 INV OUT=355.05 CB -305 STA 25+70.37 T/C-361.39 INV IN=356.80 (CB -306) INV OUT=356.70 CB -306 STA 25+70.37 T/C=361.39 INV IN=357.30 (CB -307) INV OUT=357.05 CB -307 STA 27+09.37 T/C=365.00 INV IN=360.90 (CB -308) INV OUT=360.80 CB -308 STA 27+85.20 T/C=366.97 INV OUT=362.90 GRAPHIC SCALE 40 0 20 40 80 1 inch = 40 ft. Public Sewer Collection / Extension System The city of Raleigh consents to the connection and extension of the City's public sewer system as shown on this pian. The material and Construction methods used for this project shall conform to the standards and specifications of the City's Public Utilities Handbook. City of Raleigh ( Z Public Utilities Department Permit # Authorization to Construct Date 'Siti CI Public Water Distribution / Extension ,System The city of Raleigh consents to the connection and extension of the Citys public water system as shown on this plan. The material and Construction methods used for this project shod conform to the standards and specifications of the City's Public Utilities Handbook. City of Raleigh W ?jQt o Public Utilities Department Permit # Authorization to Construct`^' Date S1 I t / C b ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH TOWN OF WAKE FOREST, CiTY OF RALEIGH & NCDOT (WHERE APPLICABLE) STANDARDS, SPECIFICATIONS, AND DETAILS. HORIZONTAL DATUM: NAD83 VERTICAL DATUM: NGVD29 THESE PLANS HAVE BEEN APPROVED FOR CONSTRUCTION BY THE TOWN OF WAKE FOREST 5 Engi eeri g Department Date f/�-�� /01 Public Works Department Date r- Ero 'on ediment on roi Date Qi_�> City of Raleigh Public Utilities Department Date Date r l , Date Date S't. Date FINAL DRAWING - RELEASED FOR CONSTRUCTION REVISIONS: OWNER.- PROJECT No. ���,,►►►►►��,,,.. JPM-15010 SiiEET N0. _1 � JPM SOUTH DEVELOPMENT, LLC ���� � �s ',, , FEs • ' - DESIGNEDI FILENAME: BY: JPM15010-P1 '7208 FALLS OF THE NEUSE RD NDW P FII' SUITE 1012905 Meridian Parkway - 46 0 - DRAIN BY: NDW P - 2DD"ham'J RALEIGH NC 27815, North Carolina 27713 LicenseNo.: C-0293 ��o ti ��;�,� xoRlz. scALE: MCADAMS 1 = 40 TMADMONS RIDGE ROAD, STA. 22+5® TgiRU STA. 30+50 CONSTRUCTION I� NGS G �;C)� ` VERT. SCALE: » > (800) 733-5646 MCAdamSC:O.001n1 �i��qT •••••• ••••'� ` 1 = 4 PRINT DATE: McADAms�''�•.q;; ► ► G. DATE: l� 04-04-2016 WAEE FOREST, ORM CAR.OLMA REVISIONS: A- X �aC a 'w W t �orW t t 12"x6" TEE _ f 448 (2) 12" GV&B t ' (1) 6" GV&B 10+00.00 HYDRANGEA FIELD COU ' 25+26.37 TRADITIONS RIDGE ROAD ACCESSIBLE t _ RAMP (TYP.) 1 N t t I i i 'v 35' B -B 60' R/W _ LO SSMH-303 J 1 CB -305 30" STANDARD CURB -r") ' 487 AND GUTTER (TYP.) O 1 t 46 LF 18" RCP N 1.51% 1 t � 1 485 a; + ' 30" VALLEY 9 CURB (TYP.)iA 1 0'R CB -303A 30' 1 , 47'58'27"E 59.72' R=3 00' 11+00 6" DIP W/..2+o0 _I - S57'04'23"E 00. -- --�-- L=47.64' SSMH-10 } 30'R 04 �- 5' TRANSITION FROM 30" STANDARD CURB AND GUTTER TO 30" VALLEY CURB (TYP.) `- CB -303 64 LF 18" RCP 5' CONCRETE 00 1 87% SIDEWALK ACCESSIBLE 1 RAMP (TiP.) i 496 i -_ EX. SSMH-302 ' i I 1 i 1 20' PRIVATE STORM DRAINAGE i 1 EASEMENT (TYP.) ' I I 1 488 I 37 LF 15" RCP Q 2.84% 1 i MAIL KIOSK i ,ass i EASEMENT (TYP.) I ' CB-1oz 87 LF 15" RCP 1 ® 2.86% 25' B -B CB -103 50' R/W 2 07% " RCP 25' 3 f 0 ,._.r_�_�• CB -104 37.5 CB- 13+ B - • 22.5' BEND SSMH-101 101 1 TREE SAVE i (TYP.) I 50� FIRE HYDRANT ASSEMBLY (TYP.) COMBINED PUBLIC ACCESS EASEMENT & 30' CITY OF RALEIGH SANITARY SEWER \ EASEMENT (TYP.) 30' CITY OF RALEIGH SANITARY J \ \ SEWER EASEMENT (TYP.) / �D�Al� GEA !FIELD C®UR 1 e•S SS 0/F -e 1 FIRE HYDRANT (50' P LIC R/W) s (SEE SHEET P-5) ASSEMBLY (TYP.) , \ 13/4" TYPE "K" COPPER t IDOMESTIC WATER 1 1/ ' 1 I SERVICE WITH 5/8"WATER METER (TYP.) 4" SANITARY SEWER \ / Q�G ss - SERVICE WITH CLEANOUT 491 S19'45'09"E 495 ' 494 1 492 1 170.93' � I HIGH POINT ELEV = 361.02 HIGH POINT STA = 11+51.76 PVI STA = 11+80.00 50' NEUSE RIPARIAN BUFFER (MEASURED 50' FROM TOP OF BANK, EACH SIDE) SPACE 9+50 10+00 11 ► T"va JPM SOUTH DEVELOPMENT, LLC 7208 FALLS OF THE NEUSE RD SUITE 101 RALEIGH, NC 27615 11+00 THE JOHN R. McADAMS COMPANY, INC. 2905 Meridian Parkway Durham, North Carolina. 27713 License No.: C-0293 (800) 733-5646 ■ McAdamsCoxom 12+00 13+00 PROJECT NO. PVI ELEV = 361.41 FILENAME: JPM15010-P1 DESIGNED BY: N D W DR&WN BY: N D W HORIZ. SCALE: 1$1 = 401 VERT. SCALE: 1"= 41 DATE: 04-04-2016 = 1.7 00. ' V ISA 1 +0 RAN EA FIE C RT = oo rn o co 36 .13 ± r - M N M O O M O U U + W - SS H- 02, STA 12+15,41, 5 0' �I 11 o EXI NG CL G E RI =35).98 (4' DIA I o W Q FI ISHE C G E 'n ami 0) 360 -2. 8 U 100% �- FIN HE CL G E 0 360 ` v " EXITING. CL in COVERFH TEE O _ 18" RCP U , to 1 to ILL: s it M a 3 o " 21 IRE HYDRANT " ' w SE BLY COVER5 a N o 0 18 Mt & CIA ; 1 " CP 1 v v W W/1 15 R II t° 18" MIN 15" RCP x- 350 N 8 Ss w L T ss 34. m 350 c 3. 18 MI 15" RCP 24" MIN.-/yy/ -fSE TO ) SD TO 3S - 1 Ll RCP N O i = 7 340 9� 340 0 M (Qe Ln nt �R 330 330 F/G p� ib M �O coo 0 tp�D V' t- Obi. O N M Y of PO 9 2 Co M M 9 to M a°i pC�pD to M Ui M M N M M 9+50 10+00 11 ► T"va JPM SOUTH DEVELOPMENT, LLC 7208 FALLS OF THE NEUSE RD SUITE 101 RALEIGH, NC 27615 11+00 THE JOHN R. McADAMS COMPANY, INC. 2905 Meridian Parkway Durham, North Carolina. 27713 License No.: C-0293 (800) 733-5646 ■ McAdamsCoxom 12+00 13+00 PROJECT NO. JPM-15010 FILENAME: JPM15010-P1 DESIGNED BY: N D W DR&WN BY: N D W HORIZ. SCALE: 1$1 = 401 VERT. SCALE: 1"= 41 DATE: 04-04-2016 14+00 15+00 ' .ow 711 ` qF « 1. �. 16+00 16+50 20' PUBLIC STORM DRAINAGE EASEMENT (TYP.) 50' NEUSE RIPARIAN BUFFER (MEASURED 50' FROM TOP OF BANK, EACH SIDE) CB -102 STA 14+67.22 T/C=351.80 INV IN=347.65 (CB -102A) INV IN=347.70 (CB -103) INV OUT=347.60 CB -102A STA 14+70.69 T/C=351.80 INV OUT=347.70 CB -103 STA 13+81.27 T/C=354.38 INV IN=350.30 (CB -104) INV OUT=350.20 CB -104 STA 13+62.91 T/C=355.04 INV OUT=350.90 CB -303A STA 10+49.00 T/C=360.33 INV IN=356.00 (CB -305) INV OUT=355.90 GRAPHIC SCALE 4a 0 20 40 80 1 inch = 40 ft. Public Sewer Collection / Extension System The city of Raleigh consents to the connection and extension of the City's public sewer system as shown on this pion. The material and Construction methods used for this project shall conform to the standards and specifications of the City's Public Utilities Handbook. City of Raleigh Cj - qt, 7- Public Utilities Department Permit # Authorization to Construct-/ Date /,,►11 Public Water Distribution / Extension System The city of Raleigh consents to the connection and extension of the City's public water system as shown on this plan. The material and Construction methods used far this project shall conform to the standards and specifications of the City's Public Utilities Handbook. City of Raleigh ,,A/ - ?2 `) Public Utilities Department Permit Authorization to C ; st c - Date ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH TOWN OF WAKE FOREST, CITY OF RALEIGH & NCDOT (WHERE APPLICABLE) STANDARDS, SPECIFICATIONS, AND DETAILS. HORIZONTAL DATUM: NAD83 VERTICAL DATUM: NGVD29 THESE PLANS HAVE BEEN APPROVED FOR CONSTRUCTION BY THE TOWN OF WAKE FOREST Engin rin Depa tment Date Public rks D�rtment Date rasion &�Sediment Control Date /y�Tl Fire P_ r vention Date .i Date Date Urban Forestry Date f 6?6 / t t,'�' City of Raleigh Public Utilities Department Date FINAL DRAWING - RELEASED FOR CONSTRUCTION SHEET NO. , kr J-% N ze`�% P- P] - 20 1111 McADAMs N NGS PRINT DATE: WAS FOREST, NORTH CAROLINA 4.53 SSMH-304- FIRE HYDRANT 1 ASSEMBLY (TYP.) 12"x8" TEE ---(2) 12- GV&B (1) 8" GV&B .452 Q Q� P4 ' �f q as 451 _4 380 s ■ t SSMH-210 _ _-- M ,"OW 1 GROVE DRIVE (50 *UBLIC R/W) + w _ SEE SHEET P-4 to a / 1 89 LF 15- RCP - rvw ® 2.69% o 0 • Co ' rt L- 30" VALLEY I CURB (TYP.) 5' TRANSITION FROM 30" STANDARD CURB AND GUTTER TO 30" VALLEY CURB (TYP.) I 482 30" STANDARD CURB i AND GUTTER (TYP.) - 0 SPARROWHAWK. LANE 28+08.89 TRADITIONS RIDGE ROAD I 60' R/W 483 35' B -B • I 8" S L=17. 0.24' N5 32'58"\N CB -21 20' PRIVATE STORM,DRAINAGE i 1 EASEMENT (TYP.) GOLDFINCH ST COURTS (50 PUB R/W) as ' 1 - _ _-------� -_--SEE_SHEE _ -- a , I�• i 174 LF 15" RCP + 25' B -B 470 r- 25' B -B i 0 1.52% r 461 50' R/W 50 R/W 4 59 1 5' TRANSITION FROM 30- SSMH-207 STANDARD CURB AND GUTTER i TO 30" VALLEY CURB TYP. CB -218 � o , . t (TYP.) � • CB -213 + ACCESSIBLE J 'r 'o RAMP (TYP.) n °i 46 LF 15" RCP ' 30" STANDARD CURB 0 AND GUTTER (TYP.) I O ® 0.63% t t 47 LF 18- RCP 30" STANDARD CURB 135 LF 18- RCP ' ' ® 0.86% 20'R SS O�F B AND GUTTER (TYP.) i ® 1.89% (SEE SHEET P-5) Co 20'R_ - CB- CB -217 ^�� I FIRE HYDRANT in 130'R z 30' Q,�r ASSEMBLY (TYP.) CB -20$ UL -DE -IS; C R I - --s5' - S CB -205 ° SS 1 R�3pp STA. 19+00.00, 25' L -._ S5M -2 0 ! CB -206 <>»3s�p 25'R - '�1" P - OW K LANE I 1 ■ S1 tD? � ` I ACCESSIBLE ( 509 PTJ R/ w) i ' RAMP (TYP.) 123 LF 15" RCP i i '® 0.887. 1 I i { 478 i 10.1. STA. 14+01.29 SP RROWHAWK LAE = i O0+00.00 MEADOW GROVE DRIVE I 8"x8" TEE 481 t (3) 8- GV&B 479 t IIA80 1 i a- i t 22 LF 24" RCP 0 0.88% I 1 t i { '477 I ■� i 1 1 91 LF RCP ® 5.50%% { i 22 LF 18" RCP ' 11 0.92% i i ' 476 i i �.I. STA. 17+14.08 SPARRO 00+00.00 GOLDFINCH NEST i 50' NEUSE RIPARIAN BUFFER (MEASURED i 50' FROM TOP OF BANK, EACH SIDE v5PAdZR0W1UVVK 4- SANITARY SEWER 456 t HIGH POINT ELEV = 351.58 380 360 SERVICE WITH CLEANOUT t ACCESSIBLE 45' BEN = (TYP-) i ' RAMP (TYP.) (1) 8- GV&B N6�4� { 1 (2) 6- GV&B 9Qp 224b� r i i 1 w 4j4 ` 3/4" TYPE "K- COPPER 1 0 ~ ® 6.57% DOMESTIC WATER i CB -203 ACCESSIBLE RAMP (TYP.) 'SERVICE WITH 5/8" WATER METER (TYP.) i 134 LF 15" RCP t ® 2.91% 5' CONCRETE 2 SIDEWALK i 30 LF 15" RCP STA 12+02.32 ' 25' B -B ® 1.99% _ CB- ' rt L- 30" VALLEY I CURB (TYP.) 5' TRANSITION FROM 30" STANDARD CURB AND GUTTER TO 30" VALLEY CURB (TYP.) I 482 30" STANDARD CURB i AND GUTTER (TYP.) - 0 SPARROWHAWK. LANE 28+08.89 TRADITIONS RIDGE ROAD I 60' R/W 483 35' B -B • I 8" S L=17. 0.24' N5 32'58"\N CB -21 20' PRIVATE STORM,DRAINAGE i 1 EASEMENT (TYP.) GOLDFINCH ST COURTS (50 PUB R/W) as ' 1 - _ _-------� -_--SEE_SHEE _ -- a , I�• i 174 LF 15" RCP + 25' B -B 470 r- 25' B -B i 0 1.52% r 461 50' R/W 50 R/W 4 59 1 5' TRANSITION FROM 30- SSMH-207 STANDARD CURB AND GUTTER i TO 30" VALLEY CURB TYP. CB -218 � o , . t (TYP.) � • CB -213 + ACCESSIBLE J 'r 'o RAMP (TYP.) n °i 46 LF 15" RCP ' 30" STANDARD CURB 0 AND GUTTER (TYP.) I O ® 0.63% t t 47 LF 18- RCP 30" STANDARD CURB 135 LF 18- RCP ' ' ® 0.86% 20'R SS O�F B AND GUTTER (TYP.) i ® 1.89% (SEE SHEET P-5) Co 20'R_ - CB- CB -217 ^�� I FIRE HYDRANT in 130'R z 30' Q,�r ASSEMBLY (TYP.) CB -20$ UL -DE -IS; C R I - --s5' - S CB -205 ° SS 1 R�3pp STA. 19+00.00, 25' L -._ S5M -2 0 ! CB -206 <>»3s�p 25'R - '�1" P - OW K LANE I 1 ■ S1 tD? � ` I ACCESSIBLE ( 509 PTJ R/ w) i ' RAMP (TYP.) 123 LF 15" RCP i i '® 0.887. 1 I i { 478 i 10.1. STA. 14+01.29 SP RROWHAWK LAE = i O0+00.00 MEADOW GROVE DRIVE I 8"x8" TEE 481 t (3) 8- GV&B 479 t IIA80 1 i a- i t 22 LF 24" RCP 0 0.88% I 1 t i { '477 I ■� i 1 1 91 LF RCP ® 5.50%% { i 22 LF 18" RCP ' 11 0.92% i i ' 476 i i �.I. STA. 17+14.08 SPARRO 00+00.00 GOLDFINCH NEST i 50' NEUSE RIPARIAN BUFFER (MEASURED i 50' FROM TOP OF BANK, EACH SIDE v5PAdZR0W1UVVK I -JW --E 3 . 6p p)P v _ HIGH POINT ELEV = 351.58 380 360 u1rru oninrr CTA - I R�Ar, nn i J CB -204 3 . 6p p)P v _ I SSMH-202 _ 781 LF 24" RCP -j/ T/C=328.80 45' BEN = Q .07% 8"x6" TEE 49 (1) 8- GV&B N6�4� { 1 (2) 6- GV&B 9Qp 224b� (1) 8-x6" REDUCER i STA 19+31.39 STA 12+22.66 ' /123 LF 24" RCP T/C=361.48 100 YEAR ® 6.57% INV IN=357.40 (CB -211) FLOODPLAIN (TYP.} CB -203 INV OUT=357.30 STA 18+80.31 CB -211 5' CONCRETE STA 12+02.32 ' 475 SIDEWALK / T/C=362.09 SSMH-201 CB -203 i = CB -204 / OURTI / 474 50 LF 24" RCP OF BANK, EACH SIDE) T/C=339.83 ® 5.39% TREE SAVE (TYP.) INV OUT=353.40 I 3/4" TYPE "K" COPPER DOMESTIC DOMESTIC WATER SERVICE WITH 20' PUBLIC STORM- TORM- / DRAINAGE EASEMENT 5/8- WATER METER (TYP.) (TYP.) STA 16+73.31 T/C=345.15 _.....-- � 4- SANITARY SEWER / SERVICE WITH CLEANOUT i 473 (TYP.) INV OUT=338.10 INV IN=340.30 (CB -206) INV OUT=337.40 CB -202A CB -202 83 LF 30" RCP ® 0.72% 472 360 CB -202 CB -209 Date STA 19+28.47 STA 13+56.28 Public W ks Depar t T/C=328.80 T/C=357.46 INV IN=324.00 (CB -202A) INV IN=353.20 (CB -212) INV IN=324.00 (CB -203) INV IN=353.40 (CB -210) INV OUT=323.90 INV OUT=353.10 CB -202A CB -210 STA 19+31.39 STA 12+22.66 T/C=328.80 T/C=361.48 100 YEAR INV OUT=324.10 INV IN=357.40 (CB -211) FLOODPLAIN (TYP.} CB -203 INV OUT=357.30 STA 18+80.31 CB -211 T/C=331.60 STA 12+02.32 INV IN=326.80 (CB -204) T/C=362.09 INV OUT=326.70 INV OUT=358.00 50' NEUSE RIPARIAN BUFFER CB -204 CB -212 (MEASURED 50' FROM TOP STA 17+54.72 STA 13+56.27 OF BANK, EACH SIDE) T/C=339.83 T/C=357.46 INV IN=335.00 (CB -205) INV OUT=353.40 INV OUT=334.90 CB -217 CB -205 STA 16+73.44 STA 16+73.31 T/C=345.15 T/C=345.16 INV IN=338.20 (CB -218) INV IN=337.90 (CB -217) INV OUT=338.10 INV IN=340.30 (CB -206) INV OUT=337.40 -EX. 30' CITY OF RALEIGH STA 15 STA 87 SANITARY SEWER EASEMENT 350.4 (TYP.) BM 1998 PG 1731 & INV IN=345. INV iN=345.40 (CB -207) 1730 INV OUT=345.30 CB -207 30' CITY OF RALEIGH SANITARY STA 15+80.71 SEWER EASEMENT & TOWF T/C=350.49 GREENWAY EASEMENT INV IN=346.35 (DI -216) INV IN=346.10 (CB -208) INV OUT=345.60 CB -208 STA 14+45.39 T/C=354.79 INV IN=348.90 (CB -213) INV IN=350.70 (CB -209) INV OUT=348.65 360 GRAPHIC SCALE 40 0 20 40 80 1 inch = 40 ft. Public Sewer Collection / Extension System The city of Raleigh consents to the connection and extension of the City's public sewer system as shown on this plan. The material and Construction methods used for this project shall conform to the standards and specifications of the Citys Public Utilities Handbook. City of Raleigh Public Utilities Department Permit # Authorization to Construct�- Date `> Public Water Distribution / Extension System The city of Raleigh consents to the connection and extension of the City's public water system as shown on this plan. The material and Construction methods used for this project shall conform to the standards and specifications of the City's Public Utilities Handbook. City of Raleigh. l2 O Public Utilities Department Permit # Authorization to Construct Date i it! t ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH TOWN OF WAKE FOREST, CITY OF RALEIGH & NCDOT (WHERE APPLICABLE) STANDARDS, SPECIFICATIONS, AND DETAILS. HORIZONTAL DATUM: NAD83 VERTICAL DATUM: NGVD29 THESE PLANS HAVE BEEN APPROVED FOR CONSTRUCTION BY THE TOWN OF WAIF FOREST ' 431,3.Ir(.) Engineerin Depa tment Date 777 Public W ks Depar t Date Erosio��njj &Sediment Control A Date ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■EmEE••■■■■■■■■■■■■■■m■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■_■_■_m_•h_E_■_■_■_■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■m■■■■■■■■■ ■■■■■■■■MUNNE■■■■■■7-■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■'■■■■■■■■milm■■■■■■■■iim■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■mm■■mmmrm■_■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ilm■■■■■■■■lim■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■FiifiFilirifiYi�iiYiii1 till■�■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ r:,��■■■�■�ir,�■■■■■■■���■■■�■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■�E��■��■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■�■�■■■ ■��I�.�..�■���■■■il����■■111■■®®■�■■■■■■��■■■■■■■■■■■■■■�■■■■■■ ■■■■■�1��■®�■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■�1■■■■;'/����!!!!!1��..■��I.I■■�►w■111■■��■�■■■■■■�■1�■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■��■■■■■■■■■■■■������■■■■�■■OEC■��■■■■ ■■®■®■�Ii"���Iliii�!■.�i�■®■�■■■■■il■■■■�■■■■■■■■■■■■■■■■■ ■■■■f, "Ma ■ NONE IE SEM ■■aME■ NEON 10 INN ■■■■■■■■E■Ill■■■■E■9N0MEN 0M0■■■■■E®0_■01iMbENU►bi11■ 11ifL■1®■■■■■N[s■0■■■■■.11■■■■■■■■■■�■■ ■■■■IIS...._. __ ■■■!�■�����.®_ _®�■■■■■■■�.'►���■■■1�1■�■■■■■■■■�■■�■■■■■�■���=!■■■�.���■■■■■■�.�.___�. �■■■■■��■..11.���■■■■l�l�.IAI■Ifs■�■■■■■�■�a�■■■■■����1■■�■■■■■■■■►����.�ill■■�i��.. _�.!�1111�►���■�1�1�!■�1�■■t■■■■■�■■■■■■■■■�■■ ■Ili■MI■■ ■■ _ ®®®!'��■■■�111111��:7�/� �■�■■■■■■■■■���MENEM ■■■■� :����■■■■■■■■�►!11■►fo b■1111■II���■�1■t���■■■■■■■■■il■■■■■■■■■■■ _ . i ■■Ili■■E-��■■■■■■■■■��® • • ��■■■■■��►�■■�■■■■■■111■!.li►�.1111■III■��1■���■■■■■■■1■■■�■■■��■■■■■ - • ■■■�■■■■■■■■■■■■■■■�®.:_ _®■■■1111111■iII��'��■■111■■■■�■■■®®�®�■■ ■■■■■■■■■�����■■■�!�l����■ �r.��.�r��iill■■li�:�il■■■■■■■■�■■■i�■■■■■■■■■■ ■■■■■'■■■■■■■■■■■■■■■■■�®i11�E�i��t■�■■■ _®illllli�lll■■■■�■�■■■■�►�■■��/�■■■■ ��.� son ■■ ■■_� ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■�■■■■■■■■■R■■■�■■■1 11I'111;��■�■ie1lli1iil�111■■►■■ ■■■■ i,' ■■■■■■■■■■■■■■1■■■1■■■■1■■�■■■■■■■■�■■■■■■■■■■■■■■■■■■■■■■�■■�■■■�■■■■_■■■■_■■■■_■■■■..■■■■_ ■■_■_ I1iL.11l11�i1►.�r.ta'.��".�r�r1'����. ll ■�!�-■■.�: �■_''!'.■� ■hi�.'.'���II■■■■■■■■■�1 �■�■m■1i�■riI11lI_11li�1,1_�■�•■�1�W■i��!1i1 11A■■�1■■Ea� ■■�'!'®'■■I'ylit!■■■■■■■■'■■■■■����■��■■■■■■■■■■E■■■�W■i■�ll _ ���►�"�\'►��zi' ■■■MM 0 /1 31.0-11102-82A _02 �■ ►_ "2■1111■ moll 11rMi•_' ■I1 ■■■■■■■■■■■■■■■�■■■■�■■■►m�®��►■� '■'©�®`!I.�I ■■■■►1�■■�1�, ■■■l■'�■■■■�'■■■■�■■■■■■■■■■■■■■■■■■■■■■■■■■ 11111161110 ENV 11.-E1111111Immaril 11■ll�iiihl���llll ■■■■■■■■■■■■■■■�■■■�I■■■1■til■��:�i��!�1,1�\�i.1■■���� = ■i� . �■■■ll����■■ ■■■■■■■■■■■■■■��■■■■■�■■■■■■■��tr�■�..®''��L�1�..��III■I�1�....II ■■■■■■■■■■■■■■■■■■■�I■■■1■X81■■■■II��..!II►1■►.��i�nr�1■��■■��■■■■■ ■■■■■■■■■■■■■■■■�■!�■■■■■■■■■■■■`��\��■ l ��■IIII�■�■_1111 ■■■■■■■■■■■■■■■■■■■ I■■■1■ ONCE■11110MMEMEM■■■■■■ . •'� _ ®�'I�1■����"� �3�■■■■■■■■■■■■■■■■■�1�■■�■��1�■■■1■■Ill ■■■►���\!�11■II��■■ISI■■■■��■ ®�II11 ■■■■■■■■■■■■■■■■■■■�I�■■1■��1■■■■1■■11 ���■■���►�mll�ll■■��1�31�!!■�■� ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■®�����■1111■■�®t ■■■■■■■■■■■■■■■■■■■�I�■■1■�®�■■■■1■■■1�►�::��■\�Il���l�!��■�l�111�■■■■■■ ■■■■■■■■■■■■■■■■■■■■�■■■■■■■■■■■■■■■■■■■����1111■■■■r ■■■■■■■■■■■■■■■■■■■■�■■1■���■■■1■■X11■■����■��i���l�►�►�IIIII■�■■■■■ GRAPHIC SCALE 40 0 20 40 80 1 inch = 40 ft. Public Sewer Collection / Extension System The city of Raleigh consents to the connection and extension of the City's public sewer system as shown on this plan. The material and Construction methods used for this project shall conform to the standards and specifications of the Citys Public Utilities Handbook. City of Raleigh Public Utilities Department Permit # Authorization to Construct�- Date `> Public Water Distribution / Extension System The city of Raleigh consents to the connection and extension of the City's public water system as shown on this plan. The material and Construction methods used for this project shall conform to the standards and specifications of the City's Public Utilities Handbook. City of Raleigh. l2 O Public Utilities Department Permit # Authorization to Construct Date i it! t ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH TOWN OF WAKE FOREST, CITY OF RALEIGH & NCDOT (WHERE APPLICABLE) STANDARDS, SPECIFICATIONS, AND DETAILS. HORIZONTAL DATUM: NAD83 VERTICAL DATUM: NGVD29 THESE PLANS HAVE BEEN APPROVED FOR CONSTRUCTION BY THE TOWN OF WAIF FOREST ' 431,3.Ir(.) Engineerin Depa tment Date 777 Public W ks Depar t Date Erosio��njj &Sediment Control A Date Date Date 5 - Date Urban Forestry Date ?,;h3 501 1%. City of Raleigh Public Utilities Department Date 9+50 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 20+00 FINAL DRAWING - RELEASED FOR CONSTRUCTION REVISIONS: OWNER: ,��� ,,��� PROJECT NO. JPM-15010 ♦» � u � t SHEET N0. 0 M SOUTH DEVELOPMENT LLC TM JOHN R McADAMS �•� .CSAR <�?� `' JPM15010-P1 ()JLN - JP COMPANY, INC. DESIGNED BY: NDW PIANN & PROFILE 7208 FALLS OF THE NEUSE RD 2905 Meridian Parkway L = DRAWN BY: NDW PHASE 2D J MCADAMS SUITE 101 Durham, North Carolina 27713 24680 1 RALEIGH N C 2 7 615 License No. • C-0293 ? �o : �� : H°RIZ. SCAM: 1 " = 40' SPARROWHAWK LANE, STA. 9+50 THRU STA. 20+00 f •� i iJ�;•• .` VERT. SCALE: » , CONSTRUCTION DRAWINGS PRINT DATE: (800) 733-5646 ■ McAdamsCo.com .,'Lq '•••..... pfl . 1 = 4 McADAms,y�N GDATE: WAKE FOREST, NORM CAROLINA ``''•stilts 04-04-2016 C U) E m 3 U Z 0 W E 0 a iN N r 0 FL I 0 0 n0. a rn 0 0 9PARROWHAWK M (50' PUBLIC R/W) SEE SHEET P-3 476 50' R/W " --- _ 25' B -B SSMH-204 SSMH-203 17+14.08 SPARROWHAWK LANE \ 8"x6" TEE (1) 8" GV&B (2) 6" GV&B \ (1) 8"x6" REDUCER ACCESSIBLE - 'SZA P (TYP.) SSMH-202 _ `J CB -218 STA 10+43.36 CB -217 ! I T/C=343.02 ACCESSIBLE ! 462, INV IN=338.90 (CB -219) RAMP (TYP.) ! INV OUT=338.60 I I / 47 CB -219 / STA 11+23.37 ® 0..88 6%% RCP ! ! T/C IN -340.90 (CB -220) a f 4" SANITARY SEWER INV 79 LF 15" RCP / INV OUT=340.80 ®2 17% SERVICE WITH CLEANOUT (rn'•) CB -220 ! n ! / 3/4" TYPE "K" COPPER STA 12+02.89 " + SSMH-208 ! DOMESTIC WATER SERVICE WITH T/C=347.01 i- CB -218 77 LF 2.47% RCP/ e 30" VALLEY ! ! 5/8" WATER METER (TYP.) INV IN=342.70INV OUT 342.60 CB -221) SSMH-207 ! CURB (TYP.) / CB -221 ` 1 C` 9 25' B -B 1 50' R/W - STA 347.0187 ! ` T/C=347.01 r50'R / INV OUT=342.90 3p� pp - 25' CB -222 pl B3 ` STA 10+43.34 CB -2 .5'R37.5'R T/C=343.02 FIRE HYDRANT INV OUT=338.90 \\\� tt" c� cc►�u_�no ASSEMBLY (TYP.) 45• BEND` 1 360 9+50 10+00 11+00 12+00 13+00 13+50 ' 4 SPARROWIUWK LSE - t N N x z M (50' PUBLIC R/W) r V'o , ' SEE SHEET P-3 t P�OPSE tit1 480 t � t _ 25' STREET YARD 1 - BUFFER (TYP.) E 30" STANDARD CURB 30" STANDARD o AND GUTTER (TYP.) AND GUTTER (TYP.) Lo ACCESSIBLE RAMP (TYP.) a-` �' ? FIRE HYDRANT��v -P-,L-12+88.69 MEADOW CL ROYAL MILL AVENUE ASSEMBLY (TYP.) �� 479 t 20'R q s` SSMH-205 t 22 LF 15" RCP 0 0.88% 30'R + SSMH-210 ` 20'R STA. 1Q+00.00 MEADOW G V _ 8" _ 01.29 SPARROWHAWK LANE 8"x8" TEE N34• 0'R Ni 5 - 3 8" GV&B t _ 2741 CB -215 aa'" EX. 12"x8" CROSS WITH _ O 30 t4p.s� -� -_ (2) 12" GV&B B-21 R=200-00'11 10 (2) 8" GV&B a L=99.60' ? q; _ 20'R �. B-214 ACCESSIBLE 478 RAMP (TYP.) - ---- 20'R'' '< REMOVE EX. 8" BLOW -OFF t a.ASSEMBLY AND EXTEND 8" t ` 95 LF 15" RCP 5' CONCRETE 25' B -B DIP W/L t ® 0.647* SIDEWALK z t 46 LF 15" RCP 459 50' R/W Co t 0.63%00 i w CB -208 i _ - 5' TRANSITION FROM 30" <v STANDARD CURB AND GUTTER t TO 30" VALLEY CURB (TYP.) 25' B -B _ , _ 4" SANITARY SEWER t EX. FIRE HYDRANT 50' R/W SERVICE WITH CLEANOUT i ASSEMBLY (TYP.) ; (TYP-) t 3/4" TYPE "K" COPPER t DOMESTIC WATER SERVICE WITH _ 5/8" WATER METER (TYP.)MmAr-E-ADOW GROVE DRIVE i 380 3RO ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■l■■■■■■■■ ■■■■■m■m aTiZim■_■_m_iTffso■■■■■■■■■■■■■■■mo:7■■■ ■■■■■ ■■■■■m■■■■■■■■■■■■ma®■■■■■■■■■mI 291 ■■ ■■■■■ ■■■■■m■■I■■m■m■■■■■a■■■■■■■ma■■Imm:l■■■m■■■ ■■■■■■■■ii■■■■ii■■■r■■1■■■■■■■■■■O■�i■■■■■■■ ■■■■■i■■■■■■■■■■■■■■E■■■■■■■■■EV92r4i■■�■■■■■ ■■■■m■■■■■■■■■■■■■■■■■■■■■■■■■■■E■■■E■■■ i ■■om■■■■■■■■m■■■■■■m ■■■■■■■■■■■ m,lE-I-■■■{/!mlf-.Ism i i ■m■i■■■■■■■■■®■■■■■■®m■■■■■■■■■■■m■■st■■■■ i ■■■i■■■■■■■■■■ ■■■■■■m m■■■■om■■■■■ ■■MNEME■■ ■■■■E M■■■■■■■■■ ■■M■■No!2'3:id'fii■■■■■■■■m ■■■■■■■ ■■■��_■■■■■■■■ • �1■■■■■�'�. ■1!��■ �■■■_■/►�.r�■111■■■■ ■■■�� : ■[■■■■■■!1■■■■�■■■■�■■_�"■ ` • i■■i■■■■®o■■m■1/■m■■■ ii/■■■I■IIII■■■■JI■■■■ ■■■■ ■■■��■■[■■■■■■�3■■■■�■■�'�! : '.:■■■■■■■■■■===='■mmmmmm■■■■■m■i/■■■■■ ■i.■■■III■■�ii�'i'ii■!!��' `r■■1■■■■ ■■■mmm■■m■■■■■■]I■■■■■■■■Mil■■■■■■ ■■■■■■[■■■��/_�.rii/■■■illi■■[1/�!■•�/1�311/e,/■■■II■■■■■■■■■ m■■■■■■ m ■■■®1■■■■■■■■■■■111MEE ■■■■11111■■■illi■■�!!■■■�i:l>r/III:%■■ 1: ■■■■l1■t■■■■■■■I■■■■■■ ■��'�■�i`i_�:�i1■■■■■■■■■ ■■■■I■■■■■■■■■■■1I■■■■■I■■■■10■1■■■■■■L�I■■■■■■ - i ■■■■11111®-�!•i�■11!:.i% _II:__:i%■��■■il■■■_■■_�.'®-�_■ ■•■::■■■■■■■■■ ' i ■■■■11111■■_■��!III//_'■���■■■■■_■Il..���! ��/■..■■■■■■■■■■■ i ■■■■Im■[■■■■■■■■■11■■■■®I■■■■11■SI■Im■■1■lmE■■■■■■ ■■■■1111■M■ \1�■•;ii■!:: ■■■!�■■■t■■■■■1■■■■■■■■■ ■■■mImI■■■■■■m■■1■■■■■®I■■■■1■■m■Ia■■1■cI■■■■■■ ■�■■II Ili�iii�■'ii�,":�>■1■■■■■ ■■■■■1:�■■�■ ■■■■■■■■■ ■■■minimi■■■■■■■■■1■■■■■oI■■■■1■■■■iu■■1■im.1■■■■■■ ■■■■Ilii%■:iti1%■■■�1■i�■■■■■■■■■■■■■■■■■■■■■■■ ■■■■I ..: IA■■■■■■■■1■■■■■m[a■■■1■■■11111■■1■mi■■■■■■ ■■■i■mig■■a■■■■■■1■■■![I■■1■■■■1■■m■ilnsimmI■■■■■■ ■■■■1111■■�■IIII■�s�...!■■�!■■I■■..�r�.��■C�■■■■■■■■■ ■■■■'ER■SEEM■■■■■■�■■■■■■■■■■■■■■■■■■■ ■■■■1111■■■E11111_!�!�■■I■®■■■iiii■gi OM■■■■EB■_ ■1■■■■■■■■■ • ■■■E410101M■■■■N�■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■1111■I//■©III'I■M■iN■■■Mlill■gll■■■■M-■!'":ri`� i .■ «�■■■■■■■ ■■■■1111■I%■.���.....__ I■■■■■■■ I.�■■!I■III��'� _a/■I/■■! i �■■■1111■C�■■Ilii■■■t�■�.�.��1'I■/I'..�%SSSS//■■■81■■■■■■■ • ■■IIII.J■■IIII■.,,.,--......�®,.///1[i��N i■R:■i■■■SII■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■11111■■■I�1 11■■■■■■mE -imlll mmmm■■■■■■m'■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ;,� ■■■■IIII�1■■■■■"■ :■■i�i�_■�il■■■■■■■■■■■1■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ SSSS"®�■��(3+1;■■■■■■■■■■ [■■■■■■■■■■■■■■■■■■■ 9+50 10+00 11+00 12+00 13+00 13+50 ' 4 SPARROWIUWK LSE - t N N x z M (50' PUBLIC R/W) r V'o , ' SEE SHEET P-3 t P�OPSE tit1 480 t � t _ 25' STREET YARD 1 - BUFFER (TYP.) E 30" STANDARD CURB 30" STANDARD o AND GUTTER (TYP.) AND GUTTER (TYP.) Lo ACCESSIBLE RAMP (TYP.) a-` �' ? FIRE HYDRANT��v -P-,L-12+88.69 MEADOW CL ROYAL MILL AVENUE ASSEMBLY (TYP.) �� 479 t 20'R q s` SSMH-205 t 22 LF 15" RCP 0 0.88% 30'R + SSMH-210 ` 20'R STA. 1Q+00.00 MEADOW G V _ 8" _ 01.29 SPARROWHAWK LANE 8"x8" TEE N34• 0'R Ni 5 - 3 8" GV&B t _ 2741 CB -215 aa'" EX. 12"x8" CROSS WITH _ O 30 t4p.s� -� -_ (2) 12" GV&B B-21 R=200-00'11 10 (2) 8" GV&B a L=99.60' ? q; _ 20'R �. B-214 ACCESSIBLE 478 RAMP (TYP.) - ---- 20'R'' '< REMOVE EX. 8" BLOW -OFF t a.ASSEMBLY AND EXTEND 8" t ` 95 LF 15" RCP 5' CONCRETE 25' B -B DIP W/L t ® 0.647* SIDEWALK z t 46 LF 15" RCP 459 50' R/W Co t 0.63%00 i w CB -208 i _ - 5' TRANSITION FROM 30" <v STANDARD CURB AND GUTTER t TO 30" VALLEY CURB (TYP.) 25' B -B _ , _ 4" SANITARY SEWER t EX. FIRE HYDRANT 50' R/W SERVICE WITH CLEANOUT i ASSEMBLY (TYP.) ; (TYP-) t 3/4" TYPE "K" COPPER t DOMESTIC WATER SERVICE WITH _ 5/8" WATER METER (TYP.)MmAr-E-ADOW GROVE DRIVE i 380 3RO 9+50 10+00 12+00 13+00 13+50 CB -213 STA 10+44.06 T/C=355.42 INV IN=349.30 (CB -214) INV OUT=349.20 CB -214 STA 11+39.15 T/C=354.25 INV IN=350.00 (CB -215) INV OUT=349.90 CB -215 STA 11+39.14 T/C=354.25 INV OUT=350.20 GRAPHIC SCALE 40 0 20 40 80 1 inch = 40 ft. Public Sewer Collection / Extension System The city of Raleigh consents to the connection and extension of the City's public sewer system as shown on this pion. The material and Construction methods used for this project shall conform to the standards and specifications of the City's Public Utilities Handbook. City of Raleigh Public Utilities Department Permit # Authorization to Construct - Date Public Water Distribution / Extension System The city of Raleigh consents to the connection and extension of the City's public water system as shown on this plan. The material and Construction methods used for this project shall conform to the standards and specifications of the City's Public Utilities Handbook. City of Raleigh'- ��j�} 0 Public Utilities Department Permit # Authorization to Construct~ Date I ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH TOWN OF WAKE FOREST, CITY OF RALEIGH & NCDOT (WHERE APPLICABLE) STANDARDS, SPECIFICATIONS, AND DETAILS. HORIZONTAL DATUM: NAD83 VERTICAL DATUM: NGVD29 THESE PLANS HAVE BEEN APPROVED FOR CONSTRUCTION BY THE TOWN OF WAKE FOREST r 15-115k. E eri Department Date Public W Departm Date Erosio & Sediment Control Date !V Date Date ,- Date vava<u rva cava y Lti.6C City of Raleigh Public Utilities Department Date REVISIONS: OWNER: ,`���,,, CA ,,,����, PROJECT No. JPM-15010 SHEET NO. 0 _ Ar lk THE JOHN R McADAMS • �i �'�` JPM15010-P1 -4) SOUTH DEVELOPMENT, LLC COi�AW, nvc. FE DESIGNED BY: ki NDW PIAN & PI�C�FL 7208 FALLS OF THE NEUSE RD2905 Meridian Parkway _ AE DRAWN BY: NDW PHASE eJ MCADAMS SUITE 101 Durham, North Carolina 27713„ 24680 1,: RALEIGH, N C 27615 License No.: C-0293 xoRlz. scALE: c • = 40 ' GOLDFINCH NEST COURT STA. 9+50 THRU STA. 13+50 CONSTRUCTION DRAWINGS (800) 733-5646 ■ McAdamsCo.com '•1gJ � ! NE••'•p�� VERT. SCALE: 1 „ _ 4, PRINT DATE: McADAms ��''4*1 IV nMEADOW GROVE DRIVE, STA. 9+50 THRU STA. 13+50 WAKE FOREST, NORTH CAROLINA l� DATE: 04-04-2016 ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■o■■■■■■s ■■■■m■■■■■■■■■■■■■■■■■■■■■■■■■■■E■■■E■■■ i ■■■■®■■■■■■■■■■■■■■■■■■■■■■■■■■■M■■M■■■■ i ■■■■EM■■■■■■■■■■■■■■■■■■■■■■■■■■o■■■■■■■ ■■■■E M■■■■■■■■■ ■■M■■No!2'3:id'fii■■■■■■■■m ■■■■■■■ ■■■■EM■■■■■■■■■■■E MEmm®■■■mmm®■m■■■■■■■ ■■■■■■■■■■■■■■■■■■UME ` • i■■i■■■■®o■■m■1/■m■■■ ■■■■ : '.:■■■■■■■■■■===='■mmmmmm■■■■■m■i/■■■■■ ■■■mmm■■m■■■■■■]I■■■■■■■■Mil■■■■■■ m■■■■■■ m ■■■®1■■■■■■■■■■■111MEE 1: ■■■■l1■t■■■■■■■I■■■■■■ ■■■■I■■■■■■■■■■■1I■■■■■I■■■■10■1■■■■■■L�I■■■■■■ ■■■■i■mi■■■■■■■■■li■■■■■[■■■■li■■■■■mmmi■■■■■■ i ■■■■Im■[■■■■■■■■■11■■■■®I■■■■11■SI■Im■■1■lmE■■■■■■ ■■■mImI■■■■■■m■■1■■■■■®I■■■■1■■m■Ia■■1■cI■■■■■■ ■■■minimi■■■■■■■■■1■■■■■oI■■■■1■■■■iu■■1■im.1■■■■■■ ■■■■I ..: IA■■■■■■■■1■■■■■m[a■■■1■■■11111■■1■mi■■■■■■ ■■■i■mig■■a■■■■■■1■■■![I■■1■■■■1■■m■ilnsimmI■■■■■■ ■■■■1111■■�■IIII■�s�...!■■�!■■I■■..�r�.��■C�■■■■■■■■■ ■■■■1111■■■E11111_!�!�■■I■®■■■iiii■gi OM■■■■EB■_ ■1■■■■■■■■■ ■■■■1111■I//■©III'I■M■iN■■■Mlill■gll■■■■M-■!'":ri`� .■ «�■■■■■■■ ■■■■1111■I%■.���.....__ I■■■■■■■ I.�■■!I■III��'� _a/■I/■■! i �■■■1111■C�■■Ilii■■■t�■�.�.��1'I■/I'..�%SSSS//■■■81■■■■■■■ • ■■IIII.J■■IIII■.,,.,--......�®,.///1[i��N i■R:■i■■■SII■■■■■■■ ■■■■11111■■■I�1 11■■■■■■mE -imlll mmmm■■■■■■m'■■■■■■■ ;,� ■■■■IIII�1■■■■■"■ :■■i�i�_■�il■■■■■■■■■■■1■■■■■■■ SSSS"®�■��(3+1;■■■■■■■■■■ [■■■■■■■■■■■■■■■■■■■ 9+50 10+00 12+00 13+00 13+50 CB -213 STA 10+44.06 T/C=355.42 INV IN=349.30 (CB -214) INV OUT=349.20 CB -214 STA 11+39.15 T/C=354.25 INV IN=350.00 (CB -215) INV OUT=349.90 CB -215 STA 11+39.14 T/C=354.25 INV OUT=350.20 GRAPHIC SCALE 40 0 20 40 80 1 inch = 40 ft. Public Sewer Collection / Extension System The city of Raleigh consents to the connection and extension of the City's public sewer system as shown on this pion. The material and Construction methods used for this project shall conform to the standards and specifications of the City's Public Utilities Handbook. City of Raleigh Public Utilities Department Permit # Authorization to Construct - Date Public Water Distribution / Extension System The city of Raleigh consents to the connection and extension of the City's public water system as shown on this plan. The material and Construction methods used for this project shall conform to the standards and specifications of the City's Public Utilities Handbook. City of Raleigh'- ��j�} 0 Public Utilities Department Permit # Authorization to Construct~ Date I ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH TOWN OF WAKE FOREST, CITY OF RALEIGH & NCDOT (WHERE APPLICABLE) STANDARDS, SPECIFICATIONS, AND DETAILS. HORIZONTAL DATUM: NAD83 VERTICAL DATUM: NGVD29 THESE PLANS HAVE BEEN APPROVED FOR CONSTRUCTION BY THE TOWN OF WAKE FOREST r 15-115k. E eri Department Date Public W Departm Date Erosio & Sediment Control Date !V Date Date ,- Date vava<u rva cava y Lti.6C City of Raleigh Public Utilities Department Date REVISIONS: OWNER: ,`���,,, CA ,,,����, PROJECT No. JPM-15010 SHEET NO. 0 _ Ar lk THE JOHN R McADAMS • �i �'�` JPM15010-P1 -4) SOUTH DEVELOPMENT, LLC COi�AW, nvc. FE DESIGNED BY: ki NDW PIAN & PI�C�FL 7208 FALLS OF THE NEUSE RD2905 Meridian Parkway _ AE DRAWN BY: NDW PHASE eJ MCADAMS SUITE 101 Durham, North Carolina 27713„ 24680 1,: RALEIGH, N C 27615 License No.: C-0293 xoRlz. scALE: c • = 40 ' GOLDFINCH NEST COURT STA. 9+50 THRU STA. 13+50 CONSTRUCTION DRAWINGS (800) 733-5646 ■ McAdamsCo.com '•1gJ � ! NE••'•p�� VERT. SCALE: 1 „ _ 4, PRINT DATE: McADAms ��''4*1 IV nMEADOW GROVE DRIVE, STA. 9+50 THRU STA. 13+50 WAKE FOREST, NORTH CAROLINA l� DATE: 04-04-2016 v 0 9+50 10+00 11+00 12+00 9+50 10+00 11+00 12+00 i c 0 i FINAL DRAWING - RELEASED FOR CONSTRUCTION 0 o PROJECT N0. r REVISIONS: OWNER: ++' �' R JPM-15010 IML 1W SHEET NO. a 1T JOHN R. McADAMS ��i FILENAME: JPM15010-P1 PLM & r` i iL 0 JPM SOUTH DEVELOPMENT, LLC COMPANY, INC. °. oF� DESIGNED BY. ON%l,.J '7208 FALLS OF THE NEUSE RD TR)kDM SH 2905 Meridian Parkway _ AL • ' = DRAWN BY: NDW SANITARY SEVER ®UTFALL "A _ SUITE 101 Durham, North Carolina 27713 4680 = HORIz. scALE: »NDW STA. 0+50 TMU STA. 12+00 MCADAMS RALEIGH, NC 2'7615 License No.: C-0293 �a Fti�INE"0 .� w, 1 = 4a N U NGS X S (800) 733-5646 ■ McAdamsCo.com moi,' ••••.....•• ��, ` VERT. SCALE: 1 f1 — 4� t! !t PRINT DATE: MCAD-A--m,,,,y,�N SANITARY SETTER ®UTFALI. B , WAKE FOP►�:ST, NORTH BAR®LIlVA .,,,jFl+' DATE` 04-04-2016 STA. 9+50 THRU STA. 12+00 The city of Raleigh consents to the connection and extension of the Citys public sewer system as shown on this plan. The material and Construction methods used for this project shall conform to the standards and specifications of the City's Public Utilities Handbook. City of Raleigh Public Utilities Department Permit # Authorization to Construct Date ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH TOWN OF WAKE FOREST, CITY OF RALEIGH & NCDOT (WHERE APPLICABLE) STANDARDS, SPECIFICATIONS, AND DETAILS. HORIZONTAL DATUM: NAD83 VERTICAL DATUM: NGVD29 THESE PLANS HAVE BEEN APPROVED FOR CONSTRUCTION BY THE TOWN OF WAKE FOREST HED CL Engiieering Department c Public WorksDepar Date — )� W;jo�&Sedlient!C:o:nttro�? Date Fire Prevention Date Accessty Date Ply 'ng Depa ent Date � 1 Date /—IFINI GRQE I N!S ED a4 M + Q E Q � EKISrrqG GL GIME L G E o N N M 350 N;'2350 2 to — i o co f 330 0 + M 1 0 0 / ;1 Q� 330 W O N C; a0 / 3�. i 1 ;;f C M 320 N � ol 000, 1 * it 0 M � 320 OR DR BLE LL RUBBER D ST B00 o " 340 / �'� M ui 340 v 0 N A Q Q>> Z Z S in c _ N In v O E M � 0 o Z i 310 z z a N N_ co O ^ 330 330 0. p 300 N �' N 300 M N M rnu t� i � Z rn c — > Z — 3 0 0 c a, rn c 3 0 320 320 0 U 2 0 9+50 10+00 11+00 12+00 9+50 10+00 11+00 12+00 i c 0 i FINAL DRAWING - RELEASED FOR CONSTRUCTION 0 o PROJECT N0. r REVISIONS: OWNER: ++' �' R JPM-15010 IML 1W SHEET NO. a 1T JOHN R. McADAMS ��i FILENAME: JPM15010-P1 PLM & r` i iL 0 JPM SOUTH DEVELOPMENT, LLC COMPANY, INC. °. oF� DESIGNED BY. ON%l,.J '7208 FALLS OF THE NEUSE RD TR)kDM SH 2905 Meridian Parkway _ AL • ' = DRAWN BY: NDW SANITARY SEVER ®UTFALL "A _ SUITE 101 Durham, North Carolina 27713 4680 = HORIz. scALE: »NDW STA. 0+50 TMU STA. 12+00 MCADAMS RALEIGH, NC 2'7615 License No.: C-0293 �a Fti�INE"0 .� w, 1 = 4a N U NGS X S (800) 733-5646 ■ McAdamsCo.com moi,' ••••.....•• ��, ` VERT. SCALE: 1 f1 — 4� t! !t PRINT DATE: MCAD-A--m,,,,y,�N SANITARY SETTER ®UTFALI. B , WAKE FOP►�:ST, NORTH BAR®LIlVA .,,,jFl+' DATE` 04-04-2016 STA. 9+50 THRU STA. 12+00 The city of Raleigh consents to the connection and extension of the Citys public sewer system as shown on this plan. The material and Construction methods used for this project shall conform to the standards and specifications of the City's Public Utilities Handbook. City of Raleigh Public Utilities Department Permit # Authorization to Construct Date ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH TOWN OF WAKE FOREST, CITY OF RALEIGH & NCDOT (WHERE APPLICABLE) STANDARDS, SPECIFICATIONS, AND DETAILS. HORIZONTAL DATUM: NAD83 VERTICAL DATUM: NGVD29 THESE PLANS HAVE BEEN APPROVED FOR CONSTRUCTION BY THE TOWN OF WAKE FOREST Engiieering Department Date Public WorksDepar Date — )� W;jo�&Sedlient!C:o:nttro�? Date Fire Prevention Date Accessty Date Ply 'ng Depa ent Date � 1 Date M t° City of Raleigh Public Utilities Department Date N!S ED CL M + Q E Q � EMG L G E o N N M 2 to — f 330 0 + M 1 Q in ai to N ;1 Q� 330 W O N 3�. i 320 ol 000, 1 * it 0 M 320 OR DR BLE LL RUBBER D ST B00 0 N S in _ N In v O M � 310 o Z i 310 z z 300 300 0 9+50 10+00 11+00 12+00 9+50 10+00 11+00 12+00 i c 0 i FINAL DRAWING - RELEASED FOR CONSTRUCTION 0 o PROJECT N0. r REVISIONS: OWNER: ++' �' R JPM-15010 IML 1W SHEET NO. a 1T JOHN R. McADAMS ��i FILENAME: JPM15010-P1 PLM & r` i iL 0 JPM SOUTH DEVELOPMENT, LLC COMPANY, INC. °. oF� DESIGNED BY. ON%l,.J '7208 FALLS OF THE NEUSE RD TR)kDM SH 2905 Meridian Parkway _ AL • ' = DRAWN BY: NDW SANITARY SEVER ®UTFALL "A _ SUITE 101 Durham, North Carolina 27713 4680 = HORIz. scALE: »NDW STA. 0+50 TMU STA. 12+00 MCADAMS RALEIGH, NC 2'7615 License No.: C-0293 �a Fti�INE"0 .� w, 1 = 4a N U NGS X S (800) 733-5646 ■ McAdamsCo.com moi,' ••••.....•• ��, ` VERT. SCALE: 1 f1 — 4� t! !t PRINT DATE: MCAD-A--m,,,,y,�N SANITARY SETTER ®UTFALI. B , WAKE FOP►�:ST, NORTH BAR®LIlVA .,,,jFl+' DATE` 04-04-2016 STA. 9+50 THRU STA. 12+00 The city of Raleigh consents to the connection and extension of the Citys public sewer system as shown on this plan. The material and Construction methods used for this project shall conform to the standards and specifications of the City's Public Utilities Handbook. City of Raleigh Public Utilities Department Permit # Authorization to Construct Date ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH TOWN OF WAKE FOREST, CITY OF RALEIGH & NCDOT (WHERE APPLICABLE) STANDARDS, SPECIFICATIONS, AND DETAILS. HORIZONTAL DATUM: NAD83 VERTICAL DATUM: NGVD29 THESE PLANS HAVE BEEN APPROVED FOR CONSTRUCTION BY THE TOWN OF WAKE FOREST Engiieering Department Date Public WorksDepar Date — )� W;jo�&Sedlient!C:o:nttro�? Date Fire Prevention Date Accessty Date Ply 'ng Depa ent Date � A Urban Forestry Date City of Raleigh Public Utilities Department Date 0 9+50 10+00 11+00 12+00 9+50 10+00 11+00 12+00 i c 0 i FINAL DRAWING - RELEASED FOR CONSTRUCTION 0 o PROJECT N0. r REVISIONS: OWNER: ++' �' R JPM-15010 IML 1W SHEET NO. a 1T JOHN R. McADAMS ��i FILENAME: JPM15010-P1 PLM & r` i iL 0 JPM SOUTH DEVELOPMENT, LLC COMPANY, INC. °. oF� DESIGNED BY. ON%l,.J '7208 FALLS OF THE NEUSE RD TR)kDM SH 2905 Meridian Parkway _ AL • ' = DRAWN BY: NDW SANITARY SEVER ®UTFALL "A _ SUITE 101 Durham, North Carolina 27713 4680 = HORIz. scALE: »NDW STA. 0+50 TMU STA. 12+00 MCADAMS RALEIGH, NC 2'7615 License No.: C-0293 �a Fti�INE"0 .� w, 1 = 4a N U NGS X S (800) 733-5646 ■ McAdamsCo.com moi,' ••••.....•• ��, ` VERT. SCALE: 1 f1 — 4� t! !t PRINT DATE: MCAD-A--m,,,,y,�N SANITARY SETTER ®UTFALI. B , WAKE FOP►�:ST, NORTH BAR®LIlVA .,,,jFl+' DATE` 04-04-2016 STA. 9+50 THRU STA. 12+00 Details Provided by APPIAN Consultinq Enq ineers - 4 6:13:31 PM PAVEMENT SECTION MATRIX UDO Street Type 2" MiN. S -9.5B BITUMINOUS Minimum Pavementti u Section a r Supp Pave;�sph aft Thickness Thlckn Aggregate EMULSIFIED ASPHALT f (See UDC?paragraph 6:72 'Town ADT Riding Intermediate Base Street Classifications" (vpd Base Geogrid1 CurlbFs forR/W5tstitmenss x l'� . Surface Course Course (ABC) SEE DETAILS ELSEWHERE Gutter section requirements. i_ FOR PIPE BEDDING (S-9.53) (119.013) (B-25:0) Urban Boulevard 25kto55k As Designed As Designed As Designed 8 Note1 Type3 (UDO 672B) a < s 4 VALLEY GUTTER A 8 Avenue 1511 to 30k As Designed As Designed As Designed 5Type - 2 (UD0 b.7.2C) Commercial Street 10k to 2 - 4 5 - Typel CU DO 6.7.2x1) Large Residential Street 2.5k to l5k 2 - 4 5 - Type 2 or 4 (UDO 6.722) Residential Yield Street Qtolk 2, - 8 Notes Type2or4 (UDO 6.722) Lane 0to3k 2 - - 8 Notel Typelor5 (UDO 6.7.2G) Ailey NIA 2 6 NIA (UD0 6.7,2M Industrial Access 3 NIA As Designed As Designed As Desigmd 8 Note l Type L For anstreet class ificationswithin the street right-of-way, the aggregate base thickness maybe reduced by inches ifan approved Geogrid is installed between the compactedsubgradeand the aggregate base. Geogrid to be Tensar BX1100 (SS -2) an approved equal, or as otherwise specif led by a NC Licensed PE (Geotechnical Engineer) 2. Curb& Gutter Types (see Standard Detail Z02). Type I- 30 -inch Standard Curb&Gutter Type 2- 30 -inch Standard 'Curb 6r Gutter or approved alternate, Type 3- 30 -Inch Standard Curb & Gutter with 5 inches ofABC below curb and extending minimum of 6 inches beyond the back of the curb or approved alternate. Type 30 -Inch Valley Curb. Type 5- LID or Swale. 3. Right-of-way and street section to be as required by Town. Engineer. 4. Streetpavement sections must be designed using the procedures outlined in the UDO,Section 3,Street and Subdivision Design, paragraph 3.3 Pavement Design Methods except that Individual elements shalt not be less than shown in.theabovetable. 5. See UDO Section 6, Infrastructure Standards, paragraphs 65.3Pedestrian/BicycleCon.nections, 6.7:2 Town Street Classification, 6.8 Sidewalk and Other Pedestrian: Facilities and 6.9 BikewayFacilities for sidewalk and bikeway requirements. TOWN of WAKE'17OREST Details Provided by APPIAN Consultin TOWN of WAKE F Manual of Specifications, Stang PAVEMENTS SECTION MATRIX .ngineers - www.opoIonenaineers.com HER scalc tel" Not To scale 2.01 Aevisiq-Tutc Shcez A Zlctober 2013 1 1 of 3 20WHEN INTERSECTING k WITH A LOCAL STREET 25' WHEN INTERSECTING WITH COLLECTOR STREETS _AV 1 � z 400 FEET MA: NOTES 1. See UD0 6.7.2 forpavement and right-of-way dimensions. D 1014 - 6:24- 21 I; - MI Provided; by APPIAN Consulting Engineers - www.oppionengineers.com 03/27/2014 6:13;21 PM I Sidewalk and curb to be 3000 psi at 28 days air entrained concrete. Sidewalk to be scored every 5 ftwith 1/2"expansionjoints at30 ft intervals Provide non-slipfinish. Concrete sidewalks to be4"except thickness to increase to 6' at all driveway crossings and for a distance either side of the driveway. Place 1/2" expansion joiln.ts at,junction of 4' and 6'sidewalk 2. Maximum grades andKn valves for streets shall follow NCDOTguidelinesforthe Piedmont area (rollingtopography). SeeTable2,03. 3. All pavement thickness'shallgenerally beconfirmed byageotechnical investigation and report. However, If a developer wishes, he maydesign residential streets usinga subgrade CBR one standard deviation to the left of the average of all CBR's determined'bygeotechnical reports thusfar. if, in the opinion of the Town's representative, soilsappear weaker or have inherent problems such as a high mica content, the services of ageotechnica I engineer shall be required in any case for the design of pavements. 4. Efectricservice willnotgo in until street section isgradedatfinal and approved. 5 The Town Engineer shall require a 1" overlay over any segment of street in which there are 3 or more trench failures, utility cuts, egregious imperfections or patches per800 foot gfstreet. Iffenal surface is a lready pl aced, it must be milled down so as not to encroach into thegutterpan. A trench failure shall be defined asa depression of i/2' or greater at the deepest paint overs trench width. Extentaf length of resurfacingsha.11 hews determined by the Town's Engineer: 6. Time limits for completion of improvement:, Refer to UDO Section 6.38. TOWN of WAKE FOREST Details Provided by Consul Mails Provided by APPIAN Consulting Engineers - www.oppionengineers.com 03/27/2014 6:13:04 Concrete Testing Reguirements: Initial Test The initial test (from first ready -mix truck) is to beta ken after the second yard is dispatched from the mixer and is to consist of the following 1. (ane stump rest 2. Pull, prepare and store 3 cytinderson-site for2g hours. 3 Temperature Subsequent Tests After the above tests are pul ted from the initial truck, every 5th truck thereafter is to be tested in the same manner as noted above. .Asphalt Testing Requirements: Compaction: Testingfor asphalt density is tofollow NCDOT'Standard Specificationsfor Roads and Structures', Section 609-7 "Field Compaction. Quality Control',andSection 609-9, "Quality Assurance latestrevision. Thickness: The minimum frequency of coring for thickness testingshall be on the basis of test sections consisting of not more than 1500 linear feet of lay down width, exclusive of intersections and irregular areas. The test sample is to be a 6 -inch cored sample. The sample is to.be numbered and logged for identification purposes. Contractor's Quality Control System: Follow NCDOT "Standard Specifications for Roads and Structures. Section 609-4 "Contractor's Quality Control Personnel Requirements' and Section 649-5, "Contractor's Quality Control Field Laboratory Requirements,' latest revision,.. Mixture and fob Mix FormulaAdjustments: Follow NCDOT'Standard Specifications for Roads and Structures',, Section 609-3. "Field Verification of Mixture and Job Mix Formula Adjustments latest revision. General: All other applicable sections of Section 609 of the NCDOT'StandatrdSpecifications for Roads and Structures" shall apply relating to Quality Control Plan, mix design., control Iimits, corrective action, equipment and measurement. TestiMCost: Project Owner isresponsibteforcost oftestling Phi Details Provided by APPIAN TOWN of WAKE FOREST, NC TOWN of WAKE FOREST NC Manual of Specifications, Standards and Design Manual of Specifications, Standards and )Design PAVEMENTS SECTION Not To Scale .01 PAVEMENTS SECTIONSWIM 2.di Not To Seale 2. MATRIX Rtv"+�aaYhtc sheet TU�Y17N O£ A +�+ �j' [==3 s6reOctober X013 2 of 3 WAKE FOREST Mil 1 R1da 3 o :n ineers - www.appionen ineers ao rn 03/27/2014- 6.21.15 PM Details Provided by APPIAN Consulting Engineers- www.oppionengineers.com 03/27/20f4- 6..25. 33 PM Dl PIPE DIAMETER C iJT PAVING HERE 2" MiN. S -9.5B BITUMINOUS SECOND `PATCHING` CUT SEAL JOINT WITH PLANT MIX - COMPACTED FOR PAVEMENT REPAIR/ EMULSIFIED ASPHALT f PATCHING (NOTE 6) (CRS -1) W B25.0B COMPACTED EXISTING PAVING FOR REPAVING FIRST "PAVEMENT OPENING SECTION PIPE __. 1'- 0" CUT" FOR PIPEST IN ALLATTON k...Fr #57STONEOR'FLOWABLE x l'� . Norz, 3 FILL CONCRETE (NOTE 5). - .l� K � y ' INS t �F <is ii t� 4 v i£ J -i 1. - SEE DETAILS ELSEWHERE �: l 7TI- I - i_ FOR PIPE BEDDING - - -I ' PIPE DIAMETER C iJT PAVING HERE LESS THAN 14" J1214' TO 36' I I=I I I=I I 71 I P- III -.,_III_ MORETHAN36' I-111-' 1 C iJT PAVING HERE `I I 1-1 11= 'Fill- '-111--I i =I I 111 FOR TRENCH I I=I I I=I I 71 I P- III -.,_III_ f RECUT PAVINGTIERE f FOR REPAVING JOINT61 •-11 PIPE __. 1'- 0" all _II MAX. MAX. #57STONEOR'FLOWABLE -,II FILL CONCRETE (NOTE 5). - SEE DETAILS ELSEWHERE a. -G 411 0 i_ FOR PIPE BEDDING MUTES: 1. Pavement repairs shall have W compacted B25.011 and 2" toppingofS9.511 mix. Compact to min, 92% Maximum Specific Gravity. 2. Trench is to be back filled in 6" lifts and compacted to 95%standard density as determined byAASHTO test method T-99 or ASTM D698 before pavement repairs are made. No excavated fi ll to be used for backfill. See detail 2.53. 3. Compaction test may be required at request of inspector: 4. All existing Town of Wake Forest paved streets and secondary roads which are open cut to install any utility, must be repaired a xccordingtothis detail. 5. Fiber optic&gas.#57 stone orflowablefif I concrete (minimum 30 psi) but min. 6'compacted class Ifor III (Definition in section 02210 - paragraph 2.1.1 of Specs) fit l overtop of fiber optic cable orgas pipe. 6. Existin.gpavement to be saw cut_ Provide a smooth uniform pavement cut without juggedor irregular edge. 7. If paving is not done I mored iately, fill final 10' with ABC until ready to pave patch. TOWN of WAKE FOREST, NC Manual of Specifications, Standards and Design FULL DEPTH ASPHALT REPAIR o�I ��- Not To Scale 2.06 TOWN of WAKE FOREST DETAIL FOR UTILITY CUTS Rcvisinntkarc. Sbrec4: October, 2013 1 of 1 Engineers - www.appionengineers.corn 3000 PSI CC3NC. 0 28 DA fS CABC STANDARD 7/2014 - 6:22:06 PM �(f NOTES: ' ,°? a a ✓ ` /6, L Residential driveway to be 12' in width Ct7DO 9.81.D) j^ ��� 2, Commercial and industrial driveways to be a maximum of 36' wide. LUDO 9.8.1.D) '� 3. All concrete shall be 3000 psi 49 28 days air entrained. 4. Curb shall be tapered to finish flush with sidewalk S. Beginning radius shall not encroach on adjacent properties based on a projection of property line from the right-of-way to the curb line. a Sidewalk section shall not be required along streets which are not planned for sidewalk 7. See also UDO9.8 Driveway Access for other requirements. 8. Concrete must come from a ready mix concrete truck to ensure mix meets air entrainment requitcments. No site mix or sakrete mix allowed. CONCRETE SIDEWALK 42" MIN. W� PLACE 1/2" EXRJOINT HERE WHEN W CROSSING EXISTING CONCRETE DRIVES a SECTION A- THICKNESS - 6' pq i z A-1 y PLACE 1/2' EXP. JOINT HERE D/W DRIVEWAY BY OTHERS ° . n RAMP PAVEMENT COMPACTED SUBGRADE -���-,.. PLACE 1/2" EXP. JOINT HERE WHEN CROSSING EXISTING CONCRETE DRIVES 6"MI THICKNESS -►1 -L I 'I=III_-1 i TOWN of WAKE FOREST, NC Manual of S ecifications, Standards and Design scalc FLARED DRIVEWAY ENTRANCE NotToscale 2.08 TOWN of WAKE FOREST TV VALLEY GUTR RG91 sh7l October, 2013 3 of 3 )VARIES, MAXIMUM SLOPE 21 COMPACTED�-�' UNDISTURBED UNLESS SHOWN OTHERWISE SUBGRADE SUBGRADE SEE UDO 6.72 -, SIDEWALK WITH UTILITY STRIP NOTES 1. Provide', ' deep tooled:scme at 5'-0" O.C. 2: Expansion joints to be placed W -Q" O.C. longitudinally, adjacent to curbs, and when butting existing structures, concrete, or buildings 3. Concrete to be 3,000 P.S t. at 28 days, air -entrained. 4. Subgrade, should not contain organic matter or plastic clays. When 'f ounc , refer to specs or contact engineer for directions.. 5. Areas of fill are to be compacted to 95% standard proctor using NCDOT Class III borrow or better. Remove topsoil before placing borrow. 8. Concrete must come from a ready mix concrete truck to ensure mix meets air entrainment requirements. No site mix or sakrete mix allowed. 9. See Specification 02400, paragraph 2.1.3 & 21.4 for expansion joint &r joint sealer specs. TOWN` of WAKE FOREST, NC Manual of S +ecifications, Standards and Design J0 TYP SIDEWALK In Not To Scale z 1 TOWN of WAKE FOREST 1 CUT or FILL SECTIONS Ria z Of October, 2013 1 oi° 1 --jL�f� ` .�f °�� FINAL DRAWING - RELEASED FOR CONSTRUCTION 1111 Ill I COMMON 11 ROBINS OPEN I C0 o '-4 U �N 19 IDM o Z 08 z ifs U U? N h v ava A o N S . 29 0 - v0 '. 0 w Q E-4 CO aQ Z z-, O O W E-4 E -4a a a �21O A a � t� V z 0 NA 1 �4 ®z PROJECT No. JPM-15010 FH.ENAME: JPM15010-D1 DESIGNED BY: N D W DRAWN BY: DLP SCALE: N.T.S. DATE: 04-04-2016 SHEET No. -1 'J! McADAMS 1/2' EXPANSIONJQINT ✓ ,:' a' `. < , l -. ,. 1/2' EXPANSION JOINT61 �a � ^� � � ~ � 4 4 � 4 ••Q a ' r'S ��� - � a. -G 411 0 v 1/2' EXPANSION JOINT a < s 4 VALLEY GUTTER A 8 Engineers - www.appionengineers.corn 3000 PSI CC3NC. 0 28 DA fS CABC STANDARD 7/2014 - 6:22:06 PM �(f NOTES: ' ,°? a a ✓ ` /6, L Residential driveway to be 12' in width Ct7DO 9.81.D) j^ ��� 2, Commercial and industrial driveways to be a maximum of 36' wide. LUDO 9.8.1.D) '� 3. All concrete shall be 3000 psi 49 28 days air entrained. 4. Curb shall be tapered to finish flush with sidewalk S. Beginning radius shall not encroach on adjacent properties based on a projection of property line from the right-of-way to the curb line. a Sidewalk section shall not be required along streets which are not planned for sidewalk 7. See also UDO9.8 Driveway Access for other requirements. 8. Concrete must come from a ready mix concrete truck to ensure mix meets air entrainment requitcments. No site mix or sakrete mix allowed. CONCRETE SIDEWALK 42" MIN. W� PLACE 1/2" EXRJOINT HERE WHEN W CROSSING EXISTING CONCRETE DRIVES a SECTION A- THICKNESS - 6' pq i z A-1 y PLACE 1/2' EXP. JOINT HERE D/W DRIVEWAY BY OTHERS ° . n RAMP PAVEMENT COMPACTED SUBGRADE -���-,.. PLACE 1/2" EXP. JOINT HERE WHEN CROSSING EXISTING CONCRETE DRIVES 6"MI THICKNESS -►1 -L I 'I=III_-1 i TOWN of WAKE FOREST, NC Manual of S ecifications, Standards and Design scalc FLARED DRIVEWAY ENTRANCE NotToscale 2.08 TOWN of WAKE FOREST TV VALLEY GUTR RG91 sh7l October, 2013 3 of 3 )VARIES, MAXIMUM SLOPE 21 COMPACTED�-�' UNDISTURBED UNLESS SHOWN OTHERWISE SUBGRADE SUBGRADE SEE UDO 6.72 -, SIDEWALK WITH UTILITY STRIP NOTES 1. Provide', ' deep tooled:scme at 5'-0" O.C. 2: Expansion joints to be placed W -Q" O.C. longitudinally, adjacent to curbs, and when butting existing structures, concrete, or buildings 3. Concrete to be 3,000 P.S t. at 28 days, air -entrained. 4. Subgrade, should not contain organic matter or plastic clays. When 'f ounc , refer to specs or contact engineer for directions.. 5. Areas of fill are to be compacted to 95% standard proctor using NCDOT Class III borrow or better. Remove topsoil before placing borrow. 8. Concrete must come from a ready mix concrete truck to ensure mix meets air entrainment requirements. No site mix or sakrete mix allowed. 9. See Specification 02400, paragraph 2.1.3 & 21.4 for expansion joint &r joint sealer specs. TOWN` of WAKE FOREST, NC Manual of S +ecifications, Standards and Design J0 TYP SIDEWALK In Not To Scale z 1 TOWN of WAKE FOREST 1 CUT or FILL SECTIONS Ria z Of October, 2013 1 oi° 1 --jL�f� ` .�f °�� FINAL DRAWING - RELEASED FOR CONSTRUCTION 1111 Ill I COMMON 11 ROBINS OPEN I C0 o '-4 U �N 19 IDM o Z 08 z ifs U U? N h v ava A o N S . 29 0 - v0 '. 0 w Q E-4 CO aQ Z z-, O O W E-4 E -4a a a �21O A a � t� V z 0 NA 1 �4 ®z PROJECT No. JPM-15010 FH.ENAME: JPM15010-D1 DESIGNED BY: N D W DRAWN BY: DLP SCALE: N.T.S. DATE: 04-04-2016 SHEET No. -1 'J! McADAMS Details Provided by APPIAN Consultino Enaineers www.oDnionenaineers.com 03/27/2014 - 6:14:04 PM Details Provided by APPIAN Consulting Enaineers - www.annionennineers.com n3/97/9n14 A -til -on PAA tit tnfi, Prnviriar1 by APPIAN P'nnnttltinn FnninParc - to tutu nnninn rennin oro nnm 0-4 /07 10111A r.• 1Rr. G 7, DAA (ln tnCi.+ 0rnu,4e 4 h,, AODf AAI ('--I+!- itinn Gv+n!nti - vn.,­ - nA /77. 17(11 A - r, 1.r.• A R DkA Hrr1tA1N >„vnsulvny r_nylrifz�C/S - www:uppwrlcllygus 48' TYPICAL (FULL WIDTH OF CURB RAMP) /'7Al T1r'ti IEC 11. •'f '�Grt 1\t1'111 CT A /'^iwTr^ u//Ulm - o:If. :I/ rm. 4 - PENETRATOR 3.2," _ I 10.8' I l2' 12" Itl.$" I 1:2" ri CURB RAMP 2,35 NOM. SPACING 1/8' RAD. AT 0,375 L5" I PERIMETER Wk! m � _ c -• T o.4s a END SECTION) NOTES: 1. Detectable warning System Gast in place with Penetrator anchors. See pre -approved products list. _. 2. Other sizes available to meet site specific requixexnents, Verify with Town.. 3, Truncated domes in a detectable warning surface shall have a base diameter of 0.9 inch minimum to 1.4 inches maximum, a top diameter of 50% of the base diameter minimum to 65% of the base diameter maximum, and a height of 02 inches 4, Truncated domes in a detectable warning surface shall have a center -to -center spacing of 1.6 inches minimum and 2:4 inches maximum, and a base -to -base spacing of 0.65 inches minimum, measured between the most adjacent dames on square grid. 5. Detectable warning surfaces shall extend 24 inches minimum in the direction of travel and the full width of the curb ramp, landing, or blended transition. The edge nearest the curb line shall be a minimum of,6 inches and maximum of 8 inches from curb (ICC/ANSI;A117.1 Fig C406.13.2). See notes 21 &22. b. See note 23, sheet 5. 7. Any NCDOT street must conform to DOT standard/ADA Curb Ramp detail 84-&05 sheet 1-4. TOWN of WAKE FOREST, NC Manual of Specifications, Standards and Design scalc omai14-. STANDARD DETECTABLE Not To Scale 2.13 TOWN of lkv WAKEFORESTI WARNINGSYSTEM Octobctob "nom sti>of er, 2013 1 13 of 15 LO k uUuans r-rUVIUtS Uy /ArrlfiIN >,VMn ulutiy Lnylncgls - wrww.uppluil�rlytncar�:wrli //LU.I-+ O: i/:4U rIY STANDARD NOTES 1. North Carolina General Statute I36r441 requires that all street curbs being constructed or reconstructed for.. maintenance procedures, traffic operations, repairs; correction of utilities or altered for any reason after September 1, 1973 shall provide curb ramps for the physically disabled at all intersections where both curb and gutter and sidewalks are provided and at other points of pedestrian f low. In addition, section 228 of the 1973 Federal Aid Highway Safety Act requires provision of curb ramps on any curb construction afterJuly 1, 1976 whether a sidewalk is proposed initially or is planned fora future date. The Americans with Disability Act (ADA) of 1990 extends to individuals with disabilities. Comprehensive civil rights protections similar to those provided to persons on the basis of race, sex, national origin and religion under the Civil Rights Act of 1964. These curb ramps have been designed to comply with the current ADA standards (2010 ADA Standards for Accessible Design, dated September 15 2010 6r effective March 15 2012). 2- Curb ramps are required when streets are altered for resurfacing (spanning oneintersection to another and includes udes overlay of additional material to the road surface with or without milling), reconstructed, ted, rehabilitated or widened.. Maintenance activities on streets, such: as crack filling sealing, pavement markings, surface sealing and pavement patching, are not alterations. However, if there is no block -to -block resurfacing, but resurfacing is occurring ata crosswalk itself, partial resurfacing (curb -to -curb resurfacing of a crosswalk) requires the provision of curb ramps at that crosswalk. Curb ramps are not required in the absence of a pedestrian walkway with a prepared surface nor are curb ramps . required in the absence of curb, elevation or other barrier between the street and the walkway. (USDOJ July 8, 20131 a Curb ramps are required at all curb returns. 4. Detectable warning domes are required for curb ramps. S. Single curb ramp at the center of the returm n are not peritted 6. Dimensions assume 90' centerline intersection of streets. 7. Construct the ramp surface to be stable; firm: and slip resistant. Located and construct the curb ramp type as shown in these details. 8. Curb ramps shall be constructed perpendicular to the roadway travel lane. 9. Coordinate the curb ramp and pedestrian crosswalk markings so a 4x4' clear space at the base of the curb ramp will fall within the pedestrian crosswalk lines 10. Set back distance from inside corner of an intersection crosswalk marking; to nearest edge of travel lane is 4 fleet minimum. 11, Terminate parking a minimum of 20 feet back of a pedestrian crosswalk. 12. Construct a curb ramps a minimum of 4 feet wide. Width may exceed 48". 13. Construct the running slope of the ramp at a maximum of 833% (1.- 12). 14. Allowable cross slope on sidewalks and ramps to be a maximum of 296. 15. Construct the side flare slope to a maximum of 10% measured along the curb line„ 16. Construct the counter -slope of the gutter or street at the base of the curb ramp at a maximum of 5% and maintain a smooth transition.. 17. Construct landings for sidewalk at a minimum. of 4'x4' with a maximum slope of 2% in any direction. Construct landings for median islands a minimum of Yx5' with a maximum slope of 2% in any direction. 18 To use a median island as a pedestrian refuge area, median islands will be a minimum of 6 feet wide. Construct median islands to provide passage over or through the island. 19. Small channelization islands that cannot provide a VxY landing at the top of a curb ramp, will be cut through level with the surface of the street. 20. Curb ramps with returned side curbs may be used only where pedestrians would not normally walk across the ramp such as where there the adjacent surface is plantings, other non -walking surface, or the side approach is substantially obstructed. 21, The typical2'x4' truncated dome pad shall be placed with the short dimension perpendicular to the curb. See curb ramp typical details. Truncated dome pads shall abutt the back of the curb (ICG/ANSI A117.1 Fig C406.132). 22. Curved truncated dome pads are permitted when ramp width is greater than 4 feet, 23. Color contrast required only when detectable warning plates are employed (ADA Standards for Accessible Design, section 705, Latest Edition). Recommended Min. light reflectance contrast is 70%(American`National Standard ICC/ANSI A117.1- Standard & Commentary Section 705.3, Latest Edition). Painted surface will not be acceptable. (See note 4). 24. Place a 1/2 -inch expansion joint where the concrete curb ramp joins/abuts the curb. 25. Curb ramps through median islands, single ramps at dual crosswalks or limited right-of-way situations will be handled by special details. Consult with the Town Engineer. 26. When construction is on a NCDOT Right -of -Way, construction shall conform to the latest edition of the NCDOT Roadway Standard drawings. 27. Construction of curb ramps shall conform to the latest edition of the ICC/ANSI All7, Chapter 4 Accessible; Routes. TOWN of WAKE FOREST, NC Manual of Specifications, Standards and Design STANDARD NOTES FOR TO � `� _ Not To scale 2.13 TOWN of WAKE FOREST CURD RAMPS Occtobtob ret sheet +` October,20713 14 of IS Details Provided by APPIAN Consultinq Engineers - www,aDoianenaineers.com 7/2014 7/2014 - 6:18:00 PM STANDARD NOTES (continued): 28. Curb ramps shall be provided at locations as shown on these plans or as directed by the engineer. Curb ramps shall be located as indicated in these details; however, the location may be adjusted as directed by the engineer where existing light poles, fire hydrants, drop inlets, etc, Affect placement. At these locations, not less than 2 feet of full height curb shall be placed between adjacent ramps. 29. Use air entrained 3000 psi concrete with a sidewalk finish in order to obtain a rough non-skid type surface. 30. Crosswalk widths and configuration vary but must conform to traffic design standards. 3i_ Place the inside pedestrian crosswalk lines no closer in the intersection thea would be established by bisecting the intersection radii, with an allowance of a 4"x4` maneuvering space (2003 ICC/ANSIal17 Commentary, Fig. 0406.6 &x 406.10) in the vehicular travel way when one ramp is installed. 32. Place all pavement markings in accordance with the latest edition of the Manual of Uniform Traffic Control Devices (MUTCD )published by Federal Highway Administration and the North Carolina Supplement to the MUTCD. 33 a asphalt greenways transition greenway to concrete to enable truncated dome placement. 34, Concrete must come from a ready mix concrete truck to ensure mix meets air entrainment requirements. No site mix or sakrete mix allowed TOWN of WAKE FOREST, NC Manual of Specifications, Standards and Design A*SSTANDARD NOTES FOR Not To To °�`t� scale 2.13 TOWN ofgg� cc WAKE FOREST CURBRAMPS P RGo suer October, 2013 15 of 15 FINAL DRAWING - RELEASED FOR CONSTRUCTION rM 0 QQ8 N co �U U N O U c� z 0 O kYi�1t z ^ /r -t V Iii1 V d �8 V o �� 0 ti N >� 1111 JJ,IlI 11 %N ARp 4 0 v0 AN G. Z O co � Q aA a W LO Cfl l� Q w W E'� Z AO�� aw, Q O CC) O 0 hA 1 � 0 A w rV� V PROJECT No. JPM-15010 FILENAME: JPM15010-D1 DESIGNED BY: N D W DRAWN BY: DLP SCALE: N.T.S. DATE: 04-04-2016 SUET N0. - 2 '= McADAMs f MSN. CROSSWALK SEE NOTE 10 RADIUS ! C1Y EXPAN51ONJOINTWHERE ISOMETRIC 1( IE i'`Y NEWCONCABUTSEX / • �i CONCRETE (TYPICAL) " .. PAY LIMTTS FOR t i3R$ RAMP Ae�t i I iJII�IET'I IC VIES SI13EW A / PAY LIMI TS FOR CURB RAMP o SIDEWALK AR. . / • ( 4 Fe /ISI�ME 1 RIC VIE Y♦ r PAY LIMITS FOR CURB RAMP ! �. d, OSSTRt1CTED £3R '��ts - • AREA , s> ! 47x4' MIN. LANDING SEEVARIES `- � �• NOTE 3 (THiS SHEET) aoam ..:. "-•_ t,Nm ; , , ., ,.. ,,. ,, • _: _, ... ,. »::. '�. N A URFA ,. . _ NO W .LKS SCE � .. EXPAN`aIC)NJOINI WHERE. C�° i ,� �, .�hNEW NEWGCiIVGABUTSEX Nov . EXPANSIONJOINT WHERE J GONG AB EX. z CONGRL-T'ECURB ABUTS „; , w. ... ...FORfi I,_, CROSSING •,, �: �, �,. _ .. � .. . ..,.. _ n ,.T`�, ,. .< rem ArSr! 6x12 GONCRETECURB GONCR1rTECTYPIGALJ CONCRET'E{TYPICAL) .,. ,•. _. SIDEWALK ., -SIDEWALK , _:. .-.. _. - 1x12 . .:,. -..., .< / yyDETECTABLE R x5 LAND INTERSECTIONS CONCRETE `� �. WARNING SURFACE 1 l rB 2-0`)6 �, G U �� - WARNIN S RFAGE. �e SEE NATE .. . DETAILSHOWING.TYPICAL .•....CONCRETE STOP CURB. _,. _. . _ ,. SEE SHEET 13 15 . " ....,.... :,. .. _....� . ,'�, b xJ2 NCR RB CU � _..MAX." :.:. , .. +sm �� SEE SHEET 13 of 15 Ate* s � � CTHIS SHEET) �-»--•s . / � ! s Mnx - -BAR LOCATION OF I SINGLE R$ RAMPS, S N CU � ! � / r n t 'fir : PEDESTRIAN"CRQSSWALKSANI7STOP -, E CURB DROP CURB . _. _ ., ._ 'fit ..ti _ _ Ex. cURs .� : : ._ &1: GUTTER CURB , .. '� , e _ I E -C ABLE } �. _ _ SIDDE _ LK 5 EWALK _ W .. , . LI F RTE °INTE E I N � ... .. s . .:.. _v� , ,. ,, .. _ TRANSITION ., - -.. .. ... .. .. ... r _. _ ..,_ , . _ _. ._ _.: _ , . , , . , f _ _ � , . _ _ ,� .•. _ . ,. , 4 .-• WARNING `u�ux3 .. - CURB - . .. TRANSITION � '-: '- :""^:z. .•;, '� 12 MIN. T 13 of 15 CURB - 0 .. .. . , , , , `u,.?'► �� `� Ams _ :..:; .. ,�s-^" , _ _"',Y z, / cs '� •-, _:..:. .> TRANSITIC7 ate, " K� - > �! { SEE NATES ,.. 30,31, & 32 �' , � ..-�:a-=-•' -"� C; :• SEE NC3 30,31,&32 - S OP BAR 6' MIN. CROSSWALK SEE NOT 30, 31, &r 32 Y SEE NOTE 10 CURB DROP- CURB �iG EX CURB &GUTi'ER TRANSITION< Y -CURB TRANSITION - 24' TYP. GCIRB TRANSITTOAT 24' TYP. 10.0% MAX. RADIUS VARIES y� O -y, �T�^• >' EO � C ' 833% (12.1) MAX: za` . 10.0% MAX. 1 T MIN. CURB 4' MIN. DROP 12' MIN: AiLSSITtO �g� l�.�r.J�SI 1�1 �T ,.;, �:. . - .,. ;. -SIDEWALK INTERSECTIONS CURB B CURS TRANSITION CURB TRANSITION 4 MIN. DROP CUR 4' MIN. DROP CURB GC7RBTI2AIySiTIgN" GUK$,TRANSITiON 4 MIN. DROP GtIRB 1-G. EXPANSION VARIABLES11iE 5a EXPANSION VARIABLE- AR V zES JOIN SIDEWALK 6x12 CONCIt1-rE J Sht?P2?S .: Z dINT SIDEWALK 6"x12"C ONGRETE . SLC?PE5 1�T+C}T T'C) , 4 O' p DETAILSHOWING TYPICAL (TY) GRA STRIP BEYOND 6 Y WIDE MIN. CURB RAMP (GRA SS _ ) CUB dr G E t1T 7CD,1, ;N+'1'C?• ELF A CURB V T C2N EY 01 ... _ , ; „, ; ELEVATION >. C L7 S 411 _, GL3RB Ee LOCATION F DUAL R8 QC NO U CU .RAMPS _. _ - ......... ,..,, _ . '. ,.. - „" R EM VE 2: IDEVSIALK 2 O CURBS S 6.x1 GONG- -. ., >, .. ,. PEI3ESTRiANCRC7'§SWALKSANDSTOP r,; LINES FOR TEE'NTERSECT IONS SIDEWALK J ;.. s I?EWAL a' ELEVA.TI .. '�OTE3: ,, RB, PRO CURB TIE IN MVA ?:... , I -- EX. CURB Sx .: •.: ass;_. .. -. 8ss.^. $' _ ___BS �- -�----=------ EX. Gti12B DETECTABLE GUTTERLTNE � :': T4s ._.u,s. s;.nxs, . ..:...... EX. CURB DETECTABLE GUTTERLIh7E EX. GRASS = " = ., . .'` `- +'-I I) 10%MAx Cu7TErz AREA 1-I _ - St GUTTER WARNING DOMES CUR B ELE ATIC}N SY GUTTER WARN INC DOMES CURS ELENA TIOI>T ,., I 4. • a. b`X-IT* Qa °a a CONCRETE . ,. e . o , c < : . ' . - - - J D{ CURB DETECTABLE - y LANDING WARNTNCsEC SECTION ASA DOMES EX. EX. SIDEWALK RAMP"CVARIES) MAX. SLOPIE 121 GUTTER A•NEMENT ". RAMP' (VARIES) RAMP )VARIES): EX. CURB SIDEWALK MAX. SLOPE 8:33% 12:1 MAX. SLOPE 8,33%12:1 Sz GUTTER PAVEMENT i EANS1ONJd b' RAMPMAX 5Lt3PE;' EXPANSIONJOINT L SEE 6 MJN.CROSSWA K SEE NOTE 10 SEE SHEET 13 of 15' EXPANSION, : ' 6" 12 .CONC: , C i7EtB - - - - - - - - - - -'- JC)IN I "~' ' DROP EXPANSION :t 6"x1 " GC}NC ' CURB JOINT DROP VARIES _ _. RADIUS _ EX. EX _------ --- - CURB CURB FOI2. TEE SIDEWALK RAMP VARIES MAX.SLOPE121 5 MiN.LANDII�IGWIDTH; RAMP ARIESS MAX,SLOPE121. SIDEWALK -III- I <' ; < - A: 4. ' _ i �. :. ...4-... ." '., ..' '.:: , DBTE-C 3LE WA KING IDOMES EXPANSIONJOINT 4EESHEE]C 13 rf"15 'EXPANSIONJOINT ..t.. < _ . • •:: .. SIDEWALK r m . _ ,.5 INTERSECTIONS TERSECT ONS _ , - _-_ =- d 11_1 I- - _.III 111_ _ .. e. _I I l ,_ < . a' R -i -Q_ 'III-,.�,_ -I. ._ I- - - - - I- - - - <. .4 5D - O >> DETAIL SLOWING TYPICAL SEE NOTE is CURB RAMPS,PEUESTRIANCRQSSWALKS 6'x12' Carse. CURB - - ..:' e: . ::...._: :: :.,, >:.. . ; '.. ,i-I� . 4 � � - . - ;; • . -. , .. ,. :: ,- . ,.. w 4 .r - - 1 ' '-' <: DETECTABLE 4'x4' LANDING. MIN. 4`x-4' LANDING. WARNING SEE NOTE 17 r X s X1z coNc corns DETECTABLE-Vx4'LANDING. 5'XS' hAI�TDNG. WARRING SEE NOTE I7 ON AND STOP LINES FOR T E INTERSECTIONS E I E `" _ e _ _ e _ _ }_ _ I a - = _ I - - _ - ) I I L_I 4 . i (I_I I t- SEE NOTE 17 ON SHEET 14 of 15 SEC TI Old Ii DOMES ON SHEET 14 of 15 SEE NOTE 17 ON SHEET 14 of 15 DOMES SHEET 14 of 15 SECTION I3 -ii SEE SHEET �, -SIDEWALK • , ,; t `'.. , ::: ... A .> �-�- _ - - s=.. 5E1 SHEET 3 of 15 13 of 15 i SECTION B -B' NOTES: NOTES: NOTES: PROPOSED CURB RAMP L Maximum curb ramp slope 833% (12:1)' L Maximum curb ramp slope 833% 012:1) L Maximum curb ramp slope 6.33% CXZ1) 2, Maximum cross slope 2,00% 2. Maximum cross slope 2.00% 2- Maximum cross slope 2.00% a Curb ramps require a (4'-M minimum landing with a maximum cross slope and longitudinal slope of 2.00% where pedestrians 3. Curb ramps require a (4'-0') minimum landing with a maximum cross slope and longitudinal slope of 2.00% where pedestrians g Pe P 3i Curb ram require a (+031 minimum landing with a maximum cross slope and longitudinal slope of 2()O% where pedestrians It I>e in Pe -SIDEWALK- �' PROPOSED OR I�YTTLIAtE SIDEWALK orm turning maneuvers. SI to drain to curb. P -f• + perform turning maneuvers. Sl to drain to curb. p perform turning maneuvers- Si to drain to curb. p� o 4. Detectable warning domes will cover T-0• length and full width of the ramp floor as shown on sheet 13 of 15._ 4. Detectable warning domes will cover 2'-0' length and full width of the ram floor as shown on sheet 13 of 15• 4. Detectable warning domes will cover 2'-0• length and full width of the ram floor as shown on sheet 13 of 13. 5. Refer to sheet 14 Sa 15 of 15 for all ramp notes. Adapted from NCWT Alternate Curb Ramp Details• 5. Refer to sheet 14 15 of 15 for all ram notes. Adopted from NCDOT Alternate Curb Ram Details. P p P_ 5. Refer to sheet 14,&r 15of 15 for all ram notes. do ted from NCDOT Alternate Curb Ram Details. pP P TOWN of WAKE FOREST, STC Manual of S ecifications, Standards and Design � _g TOWN of WAKE FOREST NC Manual of Specifications, Standards and Design g TOWN of WAKE FOREST NC Manual of Specifications, Standards and Design � � g - TOWN of WAKE KE FO REST NC Manual of Specifications, icatiolns Standards and Design � g ' LMait+a STANDARD CURB RAMP T U Not To �.�� � scrae o;t# C'� ' RB RAMPS -DIRECTIONAL L7 Not To Scale Z,..�.� ra alt# C T 'p� a � - Rp 'gam '�7 p^ 4..�.J�� iiA10`1PS SHARED LA1�t��NIT Not To 2.13 Rg M R - C ,( g N �^q nar�tn CURB itA,LR'1PS J�tiRE� LAL�ILJ�N� Not To Scale �.1� TOWN of Y �~+ Revi4mr)rtc sl =*. PLACE EI�NT DETAIL TOWN of WAKE T R�visio- rtsxc shcec�: TYPE TOWN of Reviir�wntlatc sty; TYPE TOWN of Scale ' j' Revisionrsa= s1� PE WAKE FOREST Oetober,2013 1 of 15 REST ,l October, ZtJ13 8 of LS WADE FOREST TA October, 2013 10 of 15 WAKE FOREST + October, 2013 11 of 15 Hrr1tA1N >„vnsulvny r_nylrifz�C/S - www:uppwrlcllygus 48' TYPICAL (FULL WIDTH OF CURB RAMP) /'7Al T1r'ti IEC 11. •'f '�Grt 1\t1'111 CT A /'^iwTr^ u//Ulm - o:If. :I/ rm. 4 - PENETRATOR 3.2," _ I 10.8' I l2' 12" Itl.$" I 1:2" ri CURB RAMP 2,35 NOM. SPACING 1/8' RAD. AT 0,375 L5" I PERIMETER Wk! m � _ c -• T o.4s a END SECTION) NOTES: 1. Detectable warning System Gast in place with Penetrator anchors. See pre -approved products list. _. 2. Other sizes available to meet site specific requixexnents, Verify with Town.. 3, Truncated domes in a detectable warning surface shall have a base diameter of 0.9 inch minimum to 1.4 inches maximum, a top diameter of 50% of the base diameter minimum to 65% of the base diameter maximum, and a height of 02 inches 4, Truncated domes in a detectable warning surface shall have a center -to -center spacing of 1.6 inches minimum and 2:4 inches maximum, and a base -to -base spacing of 0.65 inches minimum, measured between the most adjacent dames on square grid. 5. Detectable warning surfaces shall extend 24 inches minimum in the direction of travel and the full width of the curb ramp, landing, or blended transition. The edge nearest the curb line shall be a minimum of,6 inches and maximum of 8 inches from curb (ICC/ANSI;A117.1 Fig C406.13.2). See notes 21 &22. b. See note 23, sheet 5. 7. Any NCDOT street must conform to DOT standard/ADA Curb Ramp detail 84-&05 sheet 1-4. TOWN of WAKE FOREST, NC Manual of Specifications, Standards and Design scalc omai14-. STANDARD DETECTABLE Not To Scale 2.13 TOWN of lkv WAKEFORESTI WARNINGSYSTEM Octobctob "nom sti>of er, 2013 1 13 of 15 LO k uUuans r-rUVIUtS Uy /ArrlfiIN >,VMn ulutiy Lnylncgls - wrww.uppluil�rlytncar�:wrli //LU.I-+ O: i/:4U rIY STANDARD NOTES 1. North Carolina General Statute I36r441 requires that all street curbs being constructed or reconstructed for.. maintenance procedures, traffic operations, repairs; correction of utilities or altered for any reason after September 1, 1973 shall provide curb ramps for the physically disabled at all intersections where both curb and gutter and sidewalks are provided and at other points of pedestrian f low. In addition, section 228 of the 1973 Federal Aid Highway Safety Act requires provision of curb ramps on any curb construction afterJuly 1, 1976 whether a sidewalk is proposed initially or is planned fora future date. The Americans with Disability Act (ADA) of 1990 extends to individuals with disabilities. Comprehensive civil rights protections similar to those provided to persons on the basis of race, sex, national origin and religion under the Civil Rights Act of 1964. These curb ramps have been designed to comply with the current ADA standards (2010 ADA Standards for Accessible Design, dated September 15 2010 6r effective March 15 2012). 2- Curb ramps are required when streets are altered for resurfacing (spanning oneintersection to another and includes udes overlay of additional material to the road surface with or without milling), reconstructed, ted, rehabilitated or widened.. Maintenance activities on streets, such: as crack filling sealing, pavement markings, surface sealing and pavement patching, are not alterations. However, if there is no block -to -block resurfacing, but resurfacing is occurring ata crosswalk itself, partial resurfacing (curb -to -curb resurfacing of a crosswalk) requires the provision of curb ramps at that crosswalk. Curb ramps are not required in the absence of a pedestrian walkway with a prepared surface nor are curb ramps . required in the absence of curb, elevation or other barrier between the street and the walkway. (USDOJ July 8, 20131 a Curb ramps are required at all curb returns. 4. Detectable warning domes are required for curb ramps. S. Single curb ramp at the center of the returm n are not peritted 6. Dimensions assume 90' centerline intersection of streets. 7. Construct the ramp surface to be stable; firm: and slip resistant. Located and construct the curb ramp type as shown in these details. 8. Curb ramps shall be constructed perpendicular to the roadway travel lane. 9. Coordinate the curb ramp and pedestrian crosswalk markings so a 4x4' clear space at the base of the curb ramp will fall within the pedestrian crosswalk lines 10. Set back distance from inside corner of an intersection crosswalk marking; to nearest edge of travel lane is 4 fleet minimum. 11, Terminate parking a minimum of 20 feet back of a pedestrian crosswalk. 12. Construct a curb ramps a minimum of 4 feet wide. Width may exceed 48". 13. Construct the running slope of the ramp at a maximum of 833% (1.- 12). 14. Allowable cross slope on sidewalks and ramps to be a maximum of 296. 15. Construct the side flare slope to a maximum of 10% measured along the curb line„ 16. Construct the counter -slope of the gutter or street at the base of the curb ramp at a maximum of 5% and maintain a smooth transition.. 17. Construct landings for sidewalk at a minimum. of 4'x4' with a maximum slope of 2% in any direction. Construct landings for median islands a minimum of Yx5' with a maximum slope of 2% in any direction. 18 To use a median island as a pedestrian refuge area, median islands will be a minimum of 6 feet wide. Construct median islands to provide passage over or through the island. 19. Small channelization islands that cannot provide a VxY landing at the top of a curb ramp, will be cut through level with the surface of the street. 20. Curb ramps with returned side curbs may be used only where pedestrians would not normally walk across the ramp such as where there the adjacent surface is plantings, other non -walking surface, or the side approach is substantially obstructed. 21, The typical2'x4' truncated dome pad shall be placed with the short dimension perpendicular to the curb. See curb ramp typical details. Truncated dome pads shall abutt the back of the curb (ICG/ANSI A117.1 Fig C406.132). 22. Curved truncated dome pads are permitted when ramp width is greater than 4 feet, 23. Color contrast required only when detectable warning plates are employed (ADA Standards for Accessible Design, section 705, Latest Edition). Recommended Min. light reflectance contrast is 70%(American`National Standard ICC/ANSI A117.1- Standard & Commentary Section 705.3, Latest Edition). Painted surface will not be acceptable. (See note 4). 24. Place a 1/2 -inch expansion joint where the concrete curb ramp joins/abuts the curb. 25. Curb ramps through median islands, single ramps at dual crosswalks or limited right-of-way situations will be handled by special details. Consult with the Town Engineer. 26. When construction is on a NCDOT Right -of -Way, construction shall conform to the latest edition of the NCDOT Roadway Standard drawings. 27. Construction of curb ramps shall conform to the latest edition of the ICC/ANSI All7, Chapter 4 Accessible; Routes. TOWN of WAKE FOREST, NC Manual of Specifications, Standards and Design STANDARD NOTES FOR TO � `� _ Not To scale 2.13 TOWN of WAKE FOREST CURD RAMPS Occtobtob ret sheet +` October,20713 14 of IS Details Provided by APPIAN Consultinq Engineers - www,aDoianenaineers.com 7/2014 7/2014 - 6:18:00 PM STANDARD NOTES (continued): 28. Curb ramps shall be provided at locations as shown on these plans or as directed by the engineer. Curb ramps shall be located as indicated in these details; however, the location may be adjusted as directed by the engineer where existing light poles, fire hydrants, drop inlets, etc, Affect placement. At these locations, not less than 2 feet of full height curb shall be placed between adjacent ramps. 29. Use air entrained 3000 psi concrete with a sidewalk finish in order to obtain a rough non-skid type surface. 30. Crosswalk widths and configuration vary but must conform to traffic design standards. 3i_ Place the inside pedestrian crosswalk lines no closer in the intersection thea would be established by bisecting the intersection radii, with an allowance of a 4"x4` maneuvering space (2003 ICC/ANSIal17 Commentary, Fig. 0406.6 &x 406.10) in the vehicular travel way when one ramp is installed. 32. Place all pavement markings in accordance with the latest edition of the Manual of Uniform Traffic Control Devices (MUTCD )published by Federal Highway Administration and the North Carolina Supplement to the MUTCD. 33 a asphalt greenways transition greenway to concrete to enable truncated dome placement. 34, Concrete must come from a ready mix concrete truck to ensure mix meets air entrainment requirements. No site mix or sakrete mix allowed TOWN of WAKE FOREST, NC Manual of Specifications, Standards and Design A*SSTANDARD NOTES FOR Not To To °�`t� scale 2.13 TOWN ofgg� cc WAKE FOREST CURBRAMPS P RGo suer October, 2013 15 of 15 FINAL DRAWING - RELEASED FOR CONSTRUCTION rM 0 QQ8 N co �U U N O U c� z 0 O kYi�1t z ^ /r -t V Iii1 V d �8 V o �� 0 ti N >� 1111 JJ,IlI 11 %N ARp 4 0 v0 AN G. Z O co � Q aA a W LO Cfl l� Q w W E'� Z AO�� aw, Q O CC) O 0 hA 1 � 0 A w rV� V PROJECT No. JPM-15010 FILENAME: JPM15010-D1 DESIGNED BY: N D W DRAWN BY: DLP SCALE: N.T.S. DATE: 04-04-2016 SUET N0. - 2 '= McADAMs 0 HI -VISIBILITY CROSSWALK CONTINUOUS LINES Z m 200 0 0 +1- z yu.�'0�,= EDGE LINE Z D H O � ->i YELLOW OR WHITE 3: -n HZ- LL 000� > LANE LINE ' D :......_; , 411/6", =0yym WHITE --1 cc UJ <<LL=: y =CO 0 -0 -n SIDEWALK 4` MIN. 6' MIN. o ' Z F..i r- • 0 o H C} �� Z� DETECTABLE WARNING DOMES Z PEDESTRIAN CROSSWALK CENTER LINE 4"J61, W 0i- � O J O O a) Q • YELLOW GORE LINE -AI 0 6"/12" 4' 4' MIN. EDGE OF TRAVEL tV CL WHITE M TO CROSSWALK LINE r Z DIAGONAL LINE H S 12" 45 MPH OR HIGHER H Z - , . . >.... R .. .T E YELLOW OR WHITE " � 8" LESS THAN 4_ MPH o°000°oo 0 0000 0 3C iez— < I i SIDEWALK C/) mi) q 0 CROSSWALK LINE 8" TRANSVERSE 24" LONGITUDINAL WHITE v0 24" WHITE O A - aao 00, RxR LINE -p CnnZ Z o;o , O 16" WHITE O' X m1rammail D�i I1 STOP OR TRANSVERSE BART 24" WHITE 10'-30'/SP SKIP LINE] -- UNLESS OTHERWISED SHOWN, USE 10'-30'/SP SKIPS FOR SKIP LANE LINES AND SKIP CENTER LINES. 10' 30' C— --j 41# /6" YELLOW OR WHITE T 3'-3'/SP MINI -SKIP -SKIP LINE I UNLESS OTHERWISED SHOWN, USE 3'-3'/SP MINI -SKIPS FOR THE WHITE EDGE LINE ENTENSIONS AT ROUNDABOUTS. 3' 3' 2" WHITE 2'-6'/SP MINI -SKIP LINE UNLESS OTHERWISED SHOWN, USE 2'-6'/SP MINI -SKIPS FOR LANE LINE EXTENSIONS THROUGH INTERSECTIONS, EDGE LINE EXTENSIONS THROUGH INTERSECTIONS AND MINI -SKIPS USED FOR BICYCLE LANE LINES. 2` 6' 0= � 411/6" YELLOW OR WHITE 3'-9'/SP MINI -SKIP LINE UNLESS OTHERWISED SHOWN, USE 3'-9'/SP MINI -SKIPS FOR MINI -SKIP LANE LINES AND LINE EXTENSIONS THROUGH TAPERS. 3' 9 �' —� 4 WHITE T GENERAL NOTES: 1- USE 6" LANE, EDGE, AND CENTER LINES ON ALL FULL CONTROL OF ACCESS FACILITIES AND OTHER ROUTES AS DIRECTED BY THE ENGINEER. 2- LANE LINES INDICATED AS "WIDE" ON THE ROADWAY STANDARD DRAWINGS SHALL BE LEAST TWICE THE WIDTH OF THE NORMAL LINE. 3- GORE LINES SHALL BE TWICE THE WIDTH OF THE NORMAL LINE. Details Provided by APPIAN Consultanq Engineers - 5` 20:44 PM O` 0 LL. 0 Z LLI H Z CA Q LL Wd co 0 Z a W c Uj Uj U < z H H J Z W 0 HI -VISIBILITY CROSSWALK STANDARD CROSSWALK Z m 0 0 D H O STOPBAR = U HZ- LL > 000-=Z 0 =0yym cc UJ <<LL=: y =CO 0 -0 -n SIDEWALK 4` MIN. 6' MIN. 8" WHITE Q U Fes- o Eoi ~ _ Z Z F..i r- • 0 o H C} �� Z� DETECTABLE WARNING DOMES TO CROSSWALK PEDESTRIAN CROSSWALK CROSSWALK LINES W 0i- � O J O O a) Q • Z--H� -AI 0 1 / 4' 4' MIN. EDGE OF TRAVEL tV CL 0 TO CROSSWALK LINE �" LU M Z 0000 0 CURB RAMP 000V000 000000 o°000°oo 0 0000 0 iez— I i SIDEWALK 24" WHITE M Z CLEAR SPACE CROSSWALK LINE - aao 00, 0 -p 24" GAP CURB RAMPS o;o , Cn M mC= Y H Z Q 04 X 4' cr_0 Cis H M D CLEAR SPACE c 0 O Z > 0 O3O 10' MIN. WIDTH < Cl) �1 Z H U CQ LU H >LU 0 /) Z G ; 1- THE MINIMUM WIDTH OF STANDARD CROSSWALKS IS 6 FEET. THE MINIMUM WIDTH OF HI -VISIBILITY CROSSWALKS IS 10 FEET. LEGEND _ w H pQw�� W f� a - O2- SET BACK DISTANCE FROM INSIDE CROSSWALK MARKING TO NEAREST EDGE OF TRAVEL IS 4 MIN. 41 DIRECTION OF -.,� C'3 _10 TRAFFIC FLOW Z 3- BEYOND THE CURB FACE, A CLEAR SPACE OF 4' X 4' FEET MINIMUM SHALL BE PROVIDED WITHIN THE WIDTH OF THE CROSSWALK. CURB RAMP WITH LLI DETECTABLE 4- PLACE STOP BARS A MINIMUM OF 4 FEET FROM NEAREST CROSSWALK LINE. STOP BARS AT SIGNALIZED INTERSECTIONS SHOULD WARNING DOMES BE COORDINATED WITH THE SIGNAL DESIGN SECTION OR AS DIRECTED BY THE ENGINEER. 5- CURB RAMPS SHALL BE CONSTRUCTED IN ACCORDANCE TO THE LATEST NCDOT ROADWAY STANDARD DRAWINGS. HEET 1 OF 1 SHEET 1 OF 1 1205.07 1205.071 uetaus rrowaea Dy HrriAtN consuiting tnglneers www.appionerigineers.com U5/2//2U19 - n: n1: Ub IJM 03/27/2014 - 5:52:22 PM ■ ktJ�I /rt w� 4 WAYSTREEZ' WITHOUTCURB S 1/27'WIt7E F.L A GE Ip ORGUTTER �'EDFESTRIAN SIGN SHC)WN -�- — (R7.8a) VAN-ACICE55tBLESIGN AREA itRN 14t 4 A SPACE'. CS a YG ACC SW t:7-8) c7 C I?S0 PROPERTY LINE. taiA�. SIGN CLri' 1S O poo ' �Tyx, RESERVED g PARKING- GREEN \ Z'-6" MIN. Ort rrt �t t f x � i. ri OTHERREGULATOR STREETSIGN t� � SPEED OTS: WMI E SYMBOLSIGNS LIMIT � *556 TRAFFIC SAFETY CO. R2-1 ON 0.080" ♦ J� � I S'E�BrkC;i i�c?L z 't WITHTYPICAL L Street name signs be a minimum of - - -^ "- - - - _ ti ALUMINUM POLE GAP 1 ALUM. BLANK '� �J' b 7 ur5r ? rwt v ; h BLADE 1ItiliDWARE }} VALLEY GL rrER extruded aluminum blades See sheet 2 `r MOUNTING ASSEMBLY 2 All rPflPrrivaciancahall hPmarlPnf PnainPPr-ina r . PENALTY $250. U A TOWN of WAKE FOREST, NC Matival of S ecif icatio s, Standards acid Desi ii R7- HANDICAP I\ci T _ 9.15 i �n 4eafc: i'(_) N ESI SIGN DETAILl� x: o WAKE i t ST Fet ,, ,2011 I r E I x -s- Nluv. LJ t � _ ti t 2`-6 MIN. ti t� t� ti L� Sale: DeTW11W Not To Scale 2.22. -Revisioaibtc Sheet.*. October, 2013 1 of 2 FACE OF CURB PLAN VIEW NOTES: L +' letters to be series "C" (FHWA) 2. 2" letters to be series °C° (FHW'A) All letters and background materials to be "Scotchlite" or an approved equal and meet LTE. Specifications on reflectivity. 3. Sign appearance shall be green background with white letters. 4. Fabricate sign as follows: Base sheeting Shall be 3-M 3930 Hi-lutensity Prismatic (or equal). Overlay letter mask using 3-M U77 -C translucent EC green film. (Note: 3-M DG3 material acceptable alternative) 5. Aluminum sign blank materials to be 0.080" thick with extruded aluminum blades. Kr—ILIU C ENUEIU INSTI. ]LUIN 1 Street name sign to be one -foot f rom property line if said lines were extended. 2. Sign blades not "to extend past back of curb into road. 3. Sign location to be placed on low side of block numbering. 4. Any exceptions shall be approved by the Town Engineer. 5. Developer responsible for installation of;alI street signs. RIGIED C 10' MIN. WENT. N )TING .D BY M IEW TOWN of `WA: E FOREST, NC Manual of Specifications, Standards and Design .Seale: omatio- _ RESIDENTIAL STREET NAME SIGNS Not TO Scale 1 2.22 TOof RcviaionDatc Sheet# WAKE FOREST 1 6 3/4" SIGN HEIGHT October, 2013 2 of 2 J -- FINAL DRAWING - RELEASED FOR CONSTRUCTION M p i Ld Cq U M eq 18 o'«�yM t -i C1 O av0 *lllttllrfrr,t .�`it A '% S• , L 2 680 :`02'•.!1/ k,, c V� ��rnntll 0 W a Q U Q wW Z W Lca W t-' C\2 WE-,o� Q 0 ~ W U) W a 0 C\2 A � � 0 z 0 A U � 1 O Z w z 0 W PROJECT NO. JPM-15010 FILENAME: JPM15010—D1 DESIGNED BY: N D 1 ji% DRAIN BY: DLP SCALE: N.T.S. DATE' 04-04-2016 SHEET N0. D-3 MCADAMS Details Provided by APPIAN Engineers - www.oppionengineerscom FRAME, COVER Sz HOOD (SEE APPROVED )PRODUCT LIST AND DETAIL 172) — PSI -PF STEPS BY MA. INDUSTRIES, SEE DETAIL 2 AND NOTE 5, DETAIL 2.37) - PRECAST— CONC. RECAST—COLNC BOX NOTE 3, DETAIL 2.57 03/27/2014 6..10, 9' PM E 2 Details Provided E; APPIAN Consulting Y g FILTER FABRIC AT' EACH WEEP HOLE X DIA.'PVC WEEP HOLES CSEE NOTE 10 ON DETAIL 2.57) 3,0W PSI CONC 28 BAYS Scala [?erail& Not To Scale 2.50 Re Sheet* Dctobm 2013 1 of 3 /27/2014 - 6:11:41 PM Hm The fill height measured `oerticalty at point along the pipe from the top of the pipe to the top of the embankment at that point. SIDD Do not operate heavy equipment over any pipe culvert until the pipe culvert has been property badOilied :and covered with at kb least 3 feet of approved material. r ; `I� s I P1� - Undisturbed earth material � ft �' Bedding (Middle and Outer): Loosely placed select backfill material meeting NCDOT Gass II Type I (washed or unwashed Wished stone screenings)or Class III, Type 1 (NCDOT 2S or 2MS fine aggregate). Leave section directly beneath pipe - NCDOT Class I11, Type 1(2S or 2MS), LL < 30, PI < 6. Sandy Silt uncom cted as i seating and backfill will accomplish compaction. i� pipe 9 P P o: Select Backfill (Below springline): Select backfill material meeting NCDOT Class 11, Types 1 or 2 or NCDOT Class III, Types with less than 20% 1or2. ,• r , , , - , Backfill: Approved suitable local compar..tabie malarial above springline of pipe meeting Town of Wake Forest specficatians. 71 Fleck Foundation or Unsuitable Material Foundation; Select material NCDCJT Class V (#;t78M stone) or NCDOT Paved Areas with Class VI (#57 stone) for foundation conditioning. Encapsulate with engineering fabric as directed by the Engineer, Type 4 soil Silty Clay CL, MH, GC SC Stabilization fabric (NCDOT Table 1456-1). Overlap all transverse and longitudinal joints in fabric at !east 18 inches. Maintain (CategoryIii) the pipe foundation to a dry condition. BACKFILL(OVERFILL SOiJ "0 dal SAW CUT EDGE OF PAVEMEN EXCAVATION LINE: -� AS REQUIRED SELECT BACKFu.t B2 r BEDDING THICKNESS (Bl) SEE TABLES 16T 2 AND NOTE 5 FULLY COMPACT HAUNCH ZONE OF i PIPE SELECT I . BACKFILL. OUTER BEDDING (Bl): MATERIALS AND COMPACTION " EACH SIDLE , SAME REQUIREMENTS AS HAUNCFL COMPACT AFTER PIPE IS PLACE] 6't PRIOR TO PLACEMENT OF FII: MIDDLE BEDDING TYPE 4 FABRIC (NCDOT SECT. 1056) TOWN of WAKE FOREST, NC Manual .of Specifications, Standards and Design �q ,q Scale Detail# STORMD�y,L AI1�!AT Not To Scale wA° FOREST PIPE INSTALLATION RcvLsionihtC Sheets WN of October, 2013 1 of 3' W • SEE DETAIL 2.72 AND PRE -APPROVED PRODUCT LIST: (NCDOT DETAIL 840.(53 - SHOWN WITH TYPE IF GRATE) HEAVY DUTY FRAME, COVER &s HOOD • BIKE -FRIENDLY GRATES ARE F REQUIRED AT BIKE/PEDESTRIAN CORRIDORS. TOWN Of AKE FOREST lils Provided by AP ineers:com w w 1~ DETAIL SHOWING TYPES OF GRATES TO BE USED ACCORDING TO WATER FLOW TOWN of WAKE FO] Manual of Specifications, Standar STIP. C& G INLET W/HOOT DETAIL onsuiting Engineers - www,oppionengineers:corn 4 6:10:43 PM Details Provided by APPIAN Consul T, NC Design Scala - Detail 41 Not To Scale 2.30 ReVl9iMDatc Sheen #: October, 2013 2 of 3 03/27/2014 6:11:51 Ptv Table I Equivalent USCS3 and AASHTO Soil Classifications for SlDDb Soil Designations SIDD W kb kb m SW, SP; GW, GP - NCDOT Class 11 -Type I (crushed stone screenings), LL< 30; PI <6. _ 14m a3 - NCDOT Class I11, Type 1(2S or 2MS), LL < 30, PI < 6. Sandy Silt rnl�, - NCDOT Class I I Type s (crushed stone screenings) and Class 11, Type 2 (AASWO M1,% for �,11n) with less than 20% A-2-4 with maximum Prof 6, A-4 wf max 45% passing No. 200 Sieve and a maximum PI of 6) Typell w w 1~ DETAIL SHOWING TYPES OF GRATES TO BE USED ACCORDING TO WATER FLOW TOWN of WAKE FO] Manual of Specifications, Standar STIP. C& G INLET W/HOOT DETAIL onsuiting Engineers - www,oppionengineers:corn 4 6:10:43 PM Details Provided by APPIAN Consul T, NC Design Scala - Detail 41 Not To Scale 2.30 ReVl9iMDatc Sheen #: October, 2013 2 of 3 03/27/2014 6:11:51 Ptv Table I Equivalent USCS3 and AASHTO Soil Classifications for SlDDb Soil Designations SIDD uses NCDOTIAASHTO Gravelly Sand SW, SP; GW, GP - NCDOT Class 11 -Type I (crushed stone screenings), LL< 30; PI <6. _ (Category {) Note 5 - NCDOT Class I11, Type 1(2S or 2MS), LL < 30, PI < 6. Sandy Silt GM, SNI, Also GC, SC - NCDOT Class I I Type s (crushed stone screenings) and Class 11, Type 2 (AASWO M1,% for (Category 11) with less than 20% A-2-4 with maximum Prof 6, A-4 wf max 45% passing No. 200 Sieve and a maximum PI of 6) Typell passing #204 sieve - NCDOT Class 111, Type 1 (2S or 2MS) or Class 111, Type 2 (AASHTO MM for soil classification Wlq Category 1, Paved Areas with A-1 or A-3) Silty Clay CL, MH, GC SC A5, Ali (CategoryIii) foundation, %"ift of'H', 12" minl24" max Ia Unified Soil Classification System b Standard Installations Direct Design Table Z Standard Installations Sails and Minimum Compaction Requirements Installation Bedding Thickness Outer Bedding (BI) Haunch Zone & Select location Type LOAD RATING Note 5 Backfill Area ASTM A 48ICL4SS 35B FINNH UNDIPPED (% compaction/Category), (% compaction/Category) Typell 81 = DV6 (6" min) 95% Category l Wlq Category 1, Paved Areas with B2 = If Rock foundation or over unsuitable 950A Category 11 2' or lose bury foundation, %"ift of'H', 12" minl24" max Type 2 B1 = DI16 (6' min) 80016 Category I 85% Category I, Paved Areas with B2 = If Rock foundation or over unsuitable 90% Category l l greater than 2' of foundation, % Ift of'H',12" min124' max bury Type B1 = D116 (6" min) 851/6 Category 1 85% Category 1, In RAW outside of B2 = if Rock foundation or over unsuitable 90% Category 11 90% Category 11, or 950A Pavement foundation, Y27ft of'H , 12" min/24' max CategoryIII TYRe 4 81 = Di/6,(6' min) No Compaction required, No Compaction required, Natural Areas B2 =If Rock foundation or over unsuitable except if Category 111, use except If Category Ill, use. foundation, %s"rft of'HI,12' mint24" max 85% Category I11 85% Category ill NOTES. 1. Compaction and soilsyrribols-i.e. "95%Categoryl" refers toCategorylsoil material with minimum standard Proctor compaction of 95%. Z Soil in the outer bedding, haunch, and lower side zones, except: under the middle 113 of the pipe, shall be compacted to at least the same compaction as the majority of thesoil In.'the overfi.Il (backfill) zone. 3. For trenches, the top elevation shall be no tower than 01H belowfsraishedgrude or, for roadways, its top shall be no lower than an elevation ofd foot below the bottom of the pavement base 'material. 4, For trenches, the width shalt be wider than shown if required for adequate space to attain the speci fted compaction in the haunch and beddingzones 5. Compact outer beddingafter pipe is placed and prior toplacement ofselectftfl. Middle bedding is uncompacted. 6. Overfill (Backfill) soils to be placed per standard specifT.cation02700Storm Drainagefor the applicable backfill type and bury limitations. 7. These two tables were excerpted from Design .Data 9 and modified togenerally conform to the NCDOT Standards as shown in Detail 300.01, Rigid Pipe in Trench Condition. Reference Sources: I ACPA Design Data 9 [April, 20091 (formerly Data 40). 2. 2012 NCDOT Standard Specif cations for Roads and Structures and NCDOT Standard Details 300AI, for Rigid Pipe, "Trench Condition." TOWN of WAKE FOREST, NC Manual of Specifications, Standards and Design STORM DRAIN De.53 Not To Scale 2.J� WAK FOREST FIFE INSTALLATIONRevisimnam Sheee October, 2013 2 of 3 eers — www_appionengineers.com 03/27/2014 6:11x18 PM Details Provided by APPIAN Consulting Engineers - www:oppionengir (2)11 DLA. HANDLING HOLE- TRANSITION FROM STD. Ilk STD. CURB St vsn nr 3W! GLITTER (SEE DETAIL 30" CURB and. GUTTED a ad 4i: loofa (w1 a� 22) a ih s o� 1/7EXPANSIONJOINT - 4 DEPRESS GUTTER 1G7 .. LINE TO MEET GRATA 30' VALLEY GUTTEP (SEE DETAIL2.2) — 112" EXPANSIONJOINT DEPRESS GUT'T'ER LINE TO MEET GRATE 4 a a r i 4 5:43:25 Pvi APPROVEDMODE S EASTJORDON V-4066-1, GRATE WEIGHT 218 Lbs, FRAME WEIGHT 215 Lbs, BACK WEIGHT 140 Lbs. LOAD RATING HEAVY DUTY MATERIAL ASTM A 48ICL4SS 35B FINNH UNDIPPED IN V 1 s EJ1W OR APPROVED EQUAL. SEE 1. Frame & Cover weight may not deviate by more than -5.OT& PRE -APPROVED PRODUCT LIST. 2. Iron casting to comply with AASHTO M30& TOWN of WAKE:FOR.EST, NTC Manual of Specifications, Standards and. Design STANDARD COMBINATION Detail Not To scale 22.72 TOWN Of XvVisionrutc Sheen+ WAKE FORE STI FRAME, HOOD & GRATE (NCDOT 840.03) Octobm201-3 1 of 1 GENERAL NOTES: 1. SEE NCDOT STANDARD 840.01 FOR DETAILS BASED ON PIPE SIZE PER CROSS SECTION. 2. CONSTRUCT TWO SINGLE BASINS PER NCDOT STANDARD WITH DOUBLE INTERIOR WALL. 3. ALL CONCRETE TO BE 3600 P.S.1 COMPRESSIVE STRENGTH. 4. RASE SLAB SHALL BE MONOLITHIC. S. PIPE SECTION D2 CONNECTING CATCH BASINS SHALL HAVE A MINIMUM DIAMETER SAME AS OF OUTLET PIPE D3. 6. ALL REINFORCING STEEL SHOWN ON NCDOT STANDARDS IS TO BE PROVIDED AS CONTINUOUS MEMBERS. (NO LAPS, USED AS A SINGLE CONTINUOUS BAR IN THE SLAB) 7. WEEP HOLES SHALL BE PLACED IN BACK WALL WITH FILTER FABRIC OR STONE ON BACK SIDE)—J AL mwz i 1_>Ci.I1V114 T—T 10 to LSF i SLAB TO BE MONOLITHIC AND REINFORCING TO BE CONTINUOUS AA anac m SECTION J -J 30" TO 36 PIPE BRICK DOUBLE CATCH BASIN 15" THRU 36" PIPE J -J NOT TO SCALE I FINAL DRAWING — REI EAS FOR CONSTRUCTION M �i • �'N U co o o 8 in i N ti A QM wiV ,,`���TunTrrrr CAR v � 80 N..G Z O W a aQ E-1 :::) LO w W T-4 cfl O O a .—i U FDo a w a a �w � O C) q a � A I W � o 0z W PROJECT NO. JPM-15010 FILENAME: JPM15010-D1 DESIGNED BY: NEW W DRAWN BY: DLP SCALE: N. T. S. DATE' 04-04-2016 SHEET N0. _ iJ MCADAMS c 0 E m a. X ENI) SECTION DIMENSIONS MSTJORDONIV-4867-2 DIA, A B C D E MY 15" 6" T -T Y -7.t}' 6=1° 2'-8: 24:1 18" V 2=3" Y-10' 6-1" 3-(r 2:41 24' 10' 3'-8" 2'-6* G-2" 4'-0" 2.3a 30' V-0" 4'-6" P-$" 6'-2 5!-0' 2.5:1 42' FOR 5' MH) WITH INTERIOR ALL JOTNTs TO BE T sz' G W/ ANGLES ASFDLLOWS PREFORMED BUTYL RUBBER (MASTIC) GASKET MEETING 9(7 OR GREATER N" ASTM. C-990, FED SPEC SS -S-00210 42" 1'-7 5-3° 2'-11° 8-2" 6 6 2.5'1 Details 'Provided by APPIAN Consulting Engineers - www.appionengineers.com 2x3 DROP INLET � SEE PRE -APPROVED PRODUCTS LIST ANDDETAIL2-71 FORGRATE AND Yas�ma �x b FRAME ASSEMBLY I MORTAR COLLAR W f 4 5:52:53 PM Details Provided by APPIAN Consulting Engineers - www.appionengineers.cam 11 NOTE 11 PSI -PF STEPS BY M.A. INDUSTRIES, SEE DETAIL 2.74 ANIS NOTE 5, DETAIL 2.57) — SEE NOTES ON DETAIL #257 NO'T'E 11 � . >�i o> � ` °� Q .0 � 24" d 4 aD V1 Q• 4.. Q " wwN 21314" i 14 'M.., d d . PRECAST BOX . r� U w z d i 014 - 5:44:04 PM -o .,a�,i APPROVEDMODRS MSTJORDONIV-4867-2 GRATE WEIGHT 190 Lbs. FRAMEWEIGHT 159Lbs, LOADRATING HEAVY DUTY MATERIAL A5TMA48CLA5S35B FINISH UNDTPPED FILTER ACH WEEP HO / N C� 1 3: * ETIW OR APPROVED EQUAL SEE 2' DIA: PVC WEEP HOLES I. Frame & Cover weight may not deviate by more than -50%. PRE -APPROVED PRODUCT LIST (SEE NOTE 10 ON DETAIL 237) 2. Iron. casting to comply with AASHTO M30fi FORMED INVERT 3. Net open area -390 Sri. In. 4. For a4'highframe,Use EjIWV-5660 or approved eauaL TOWN of WAKE FOREST NC TOWN of WAKE FOMENT, NC Manual of Specifications, Standards and Design Manual of S ecifications, Standards and Design J*, STIP. Y x VARIABLE LENGTH Not oScaled2.56 _ STANDAR.D CATCH BASIN Not OScale 71 TOWNof _ p �* gp ,{WAKE FOREST 1RECAS 1 Boli Y r 1 1 H G, X 31Cly T CH BASIN O~tober> 2073WAKE FOREST ASSEMBLY FRAME GRATE �O4"�r'a� st>� w October, 2013 1 of 1 ;toils Provided by APPIAN Consulting Engineers - www.appionengineers.corn 03/27/2014 - 6:20:03 PM Details Provided by APPIAN Consulting Engineers - www.appionengineers.corn 03/27/2014 5:43:42 Ph BOLT FRAME TO CASTING (4 RF -QT)) SECURE CASTING , W/MORTAR A WA M�Jia STANDARD MANHOLE CASTING. SEE DETAIL 270 AND PRE -APPROVED PRODUCT LIST I%qv`�'�� I' / EASTJORDON V-1384 4" OR 6• PRECAST GRADE RINGS - 2311/16`DIA. (NOTE 2) MAXIMUM OF THREE GRADE RINGS - PRECAST GRADE RINGS ARE TO 12' MAX ALLOWED. OTHERWISE BE USED WHEN POSSIBLE AND ADD RISER SECTION ADWSTED WITH BRICK FINISH MORTAR COURSE. FILLJOINTS N FLn-L WITH HIGH STRENGTH d a TYPE M MORTAR Sa STRIKE FLUSH INSIDE £St OUT 2515116 DIA. (NOTE 2) r� MANUFACTURE TO LOCATE STEPS ,., OVER OUTLET PIPE. STEPS BY M.A. J, USE AN APPROVED BITUMINOUS ED BITUMI -' INDUSTRIES, INC PSI -PF OR EQUAL 6r 'q BASESEALANT BASE SEALANT TOP ;".yF , SEE DETAIL 2.74. FRAME SECTION A -A 4 USE ECCENTRIC CONE ISOMETRICS THIS DETAIL APPLIES FOR LARGEST PIPES SHOWN BELOW (LE.- 30"FOR 4'MH 42' FOR 5' MH) WITH INTERIOR ALL JOTNTs TO BE T sz' G W/ ANGLES ASFDLLOWS PREFORMED BUTYL RUBBER (MASTIC) GASKET MEETING 9(7 OR GREATER N" ASTM. C-990, FED SPEC SS -S-00210 (210A) CONSULT WITH ENGINEER � ar4 _ IF ANGLES LESS THAN 90' ON PRECAST MAM--TOLE TO MEET TWO INTERSECTING PIPES .a :o REQUIREMENTS OF ASTM C47EI, AASHT( M-199 SEE DETAIL. 2.75. a± SLOPE OF CHANNEL THRU MANHOLE 6 0.08' FALL UNLESS SHOWN OTHERWISE ON PLANS.', PRECAST OPENING REQUIRED 2" DIA.. PVC WEEP HOLE W/ FORALL PIPES. PACK GROUT / 1 CF OF CLEAN STONE ONn a AROUND ALL ANNULAR NON -WOVEN FILTER FABRIC OPENINGS SEE PLANS FOR (NOTE 10, DETAIL #22-57) fit PIPE SIZES NOTE: USE 6" EXTENDED BASE WHEN TOTAL MH a^� HEIGHT EXCEEDS 12' SET MANHOLE ON I I :SEE SPECS FOR FOUNDATION � � i, �� i��`� CTO I.2' -#57 STONE. IMPROVEMENT WHEN NEET)ED TOWN of WAKE FOREST, NC Manual of Specifications, Standards and Design TOWN of WAKE FOREST CONCRETE 4� DI A. MH JB sclxl�1�PRECAS1 NotToScale 2.60 5bof I October, 20-13 of 1 (4) I" DIA. ANCHOR BOLT. HOLES EQUALLY SPACED. BOLT FRAME TO CONE SECTION WHEN ORDERED BY CITY ENGINEER OR WATER RESOURCES. 6 11/4" LE FLUSH (2) CLOS HOLES 2511/16" DIA, (NOTE 2) EASTJORDON V-1384 231/2° DIA.. (NOTE 2) 2311/16`DIA. (NOTE 2) FRAMEWEIGHT 153 Lbs. LOAD RATTNG HEAVY DUTY MATERIAL ASTM A 48 CLASS 35B FINISH 1 N 2515116 DIA. (NOTE 2) r� 331/4' DIA. {NOTE 2) FRAME SECTION A -A ISOMETRICS 13/$" 3l4 PICKHOLE N COVER FACE In APPROVED MODELS EASTJORDON V-1384 231/2° DIA.. (NOTE 2) N FRAMEWEIGHT 153 Lbs. LOAD RATTNG In APPROVED MODELS EASTJORDON V-1384 COVERWEIGHT 128 Lb,-- b,-FRAME FRAMEWEIGHT 153 Lbs. LOAD RATTNG HEAVY DUTY MATERIAL ASTM A 48 CLASS 35B FINISH UN COATED 21P _ I COVER SECTION B -B ']') Y /1- f-1% EJIW OR APPROVED EQUAL COVERBACK NOTES: SEE PRE -APPROVED PRODUCTS LIST I. Frame &+cover weight may not deviate by more than -50%. 2. iron castingto coMplywihAASHTOM3D6. TOWN of WAKE FOREST, NC Manual sof Specifications, Standards and Design. STANDARD MANHOLE CASTING Not oSScale la 70 TOwNaf aeosr STORM DRAINAGE STRUCTURES WAKE FC7REST October, 2073 1 of 1 --=�� 311 z FINAL DRAWING - RELEkSE FOR CONSTRUCTION M p It - C4 co U Cq d -dz o8 o "co N HHH � cy ao ,�� `I ► i„ill!!! CAR F SA 0 1- AN G. , 0 aQ Z� LO W W• --i z cfl 0 w 0 > w Q 0 r� 00 0-4 0.4 a �w :�i© A a � �S 0 A A N � � V �zo �C 0 z w Z 0 PROJECT NO. JPM-15010 FILENAME: JPM15010-Di DESIGNED BY: N D W DRAWN BY: DLP SCALE: N.T.S. DATE' 04-04-2016 SHEET N0. — 'J MCADAMS FINISHED GRADE ALL AREAS GIVEN iN"SQUARE FEET. \ � Q� lo VJ NIF °° V Q `L // O 2 VO` G" G,_ I G11 P-411 w p Q w. U' / > 5 3" / tu Q m ! i 3' MIN UNDISTURBED v O ,Q� Z UOR2Oz .O. SOIL BACKFILL 2,207 0. Z.& g O zUv 2 'd G X. 1 lL 1 O 450 j, 328 2 3 3 Q Z n a Q 5 M PROPERTY MINIMUM 30 HORIZONTAL CLEARANCE LINE FROM ANY OBJECT. tfYDKANI, PUMPER NOZZLE TO BE POINTED RDS FIRS TRUCK ACCESS. IC FLANGE BETWEEN 2" - G" E -GRADE EWALK CURB AND GUTTER PAVEMENT z . VALVE BOX G" GATE VALVE CONC, THRUST N COMPACTED BACKFILL BLOCK (TAMPED IN G" LIFTS) G" MIN. BRANCH PIPE _._ RESTRAINING GLANDS MA(N —I' -3"x P -3"x 4" THICK RESTRAINING GLANDS 7 CU. FT. CRUSHED STONE MIN. UNDISTURBED EARTH. NOTES: 1. FIRE HYDRANT SHALL 13E AS MANUFACTURED: MUELLER, AMERICAN DARLING, KENNEDY, M$H, WATEROUS, CLOW, EAST JORDAN IRON WORKS, OR U5 PIPE. 2, BRANCH PIPE SHALL BE DUCTILE IRON AWWA C 150-9G 3. G" GATE VALVE SHALL 13E AWWA C500 -8G OPEN LEFT' 4. STEEL RODS AND BOLTS SHALL BE a" HOT DIPPED GALVANIZED 5, FIRE HYDRANTS WILL BG INSTALLED IN TRUE VERTICAL POSITION RODS SHALL NOT BE COUPLED MORE THAN ONCE. IF THE LENGTH FROM THE VALVE TO THE HYDRANT EXCEEDS 20' THEN A MECHANICAL RESTRAINING GLAND WITH A REBAR CAGE SHALL BE INSTALLED NO MORE THAN I O' FROM HYDRANT AND POURED IN CONCRETE. FIRE HYDRANTS TO BE LOCATED IN ROW OR 2 FOOT EASEMENT ADJACENT TO ROW ANYfiME SITE WORK, CONSTRUCTION. ROAD WORK, OR ANY OTHER WORK CHANGESTHE GRADE OF THE FIRE CITY OF RALEIGH HYDRANT, THE PER9ON RESPONSIBLE FOR THE WORK 15 RESPONSIBLE POR DEPARTMENT OF PUBLIC UTILITIES ADJUSTING THE FIRE HYDRANT TO STAY WITHIN COMPLIANCE. STANDARD FIRE HYDRANT I1\15TALLATION DETAIL DWG: NO. 1 REVISIONS I DATE I REVISIONS 0 7 0 ry 191 AMA ADE W-4 DHL G ALL AREAS GIVEN iN"SQUARE FEET. \ � Q� lo VJ NIF °° V Q `L // O 2 VO` G" G,_ I G11 P-411 w p Q w. U' 0 .tu_ > W 3" \Q tu Q m ! i i tz v O ,Q� Z UOR2Oz 7/8" 22 1/20 2,207 0. Z.& g O zUv 2 'd G 0, ID 1 lL 1 O 450 j, 328 2 3 3 ADE W-4 DHL STANDARD THRUST BLOCKING VIEWS ^ A -rm I " VISIONS DATE p1RH 3-31-00 D;H, L. I G-18-08 I 5" STORZ NOZZLE 3211 r> 22 NOZZLES W/ NATIONAL STANDARD GROUND LINE 1 5f8:: THREADS et�'r 2— mr-1 NOTES: 1. RALEIGH PUBLIC HYDRANTS SHALL BE PAINTED SOLID RED, 2, KNIGHTDALE, * KOLE5VILLF PUBLIC HYDRANTS SHALL BE PAINTED RED W/SILVER OPERATING NUTS. 3. ZEBULON PUBLIC HYDRANTS SHALL BE PAINTED RED W1 SILVER. BONNETS AND OPERATING NUTS. 4. WAKE FOREST AND GARNER, AND WENDELL PUBLIC AND PRIVATE HYDRANTS TO BE PAINTED SAFETY YELLOW WJSILVER CAPS AND OPERATING NUTS. 5. OPERATING NUTS ON HYDRANTS CONNECTED TO PUBLIC MAINS LARGER THAN 12" SHALL BE PAINTED BLACK.. CITY OF RALEIGH DEPARTMENT OF PUBLIC UTILITIES RALEIGH, GARNER, KNIGHTDALE, ROLESVILLE, WAKE FOREST, WENDELL * ZEBULON STANDARD FIRE HYDRANT WITH 5" 5TORZ PUMPER NOZZLE DWG, NO. REVISIONS I DATE REVISIONS DATE ABB 7-21-05 W-5 RRH DHL 2-18-08 REACTION BEARING AREAS POR HORIZONTAL WATER PIPE BENDS BASED ON TEST PRESSUREOf 200 P.S.I. G ALL AREAS GIVEN iN"SQUARE FEET. \ � Q� lo VJ NIF °° V Q `L // O 2 VO` G" G,_ I G11 P-411 w p Q w. U' 0 .tu_ > 1'-7" 3" . uj5��LLJ 1 I 1140 Q m ! i i tz v O ,Q� Z UOR2Oz 7/8" 22 1/20 2,207 0. Z.& g O zUv 2 � L' 0, ID 1 lL 1 O 450 j, 328 2 3 3 Q Z Q W C)'o/ 2 5 1 <<tQr 7,996 2 4 (s)t=s d'c= I ( 2 8 tu wzw.0atw PLUG 5,455 2 o!Q= U Uzz t=zya/ c" u —_tpz; I I 2 G 1 Bir CITY OF RALEIGH 1 1 1/4a 1,970 DEPARTMENT OF PUBLIC UTILITIES STANDARD THRUST BLOCKING VIEWS ^ A -rm I " VISIONS DATE p1RH 3-31-00 D;H, L. I G-18-08 I 5" STORZ NOZZLE 3211 r> 22 NOZZLES W/ NATIONAL STANDARD GROUND LINE 1 5f8:: THREADS et�'r 2— mr-1 NOTES: 1. RALEIGH PUBLIC HYDRANTS SHALL BE PAINTED SOLID RED, 2, KNIGHTDALE, * KOLE5VILLF PUBLIC HYDRANTS SHALL BE PAINTED RED W/SILVER OPERATING NUTS. 3. ZEBULON PUBLIC HYDRANTS SHALL BE PAINTED RED W1 SILVER. BONNETS AND OPERATING NUTS. 4. WAKE FOREST AND GARNER, AND WENDELL PUBLIC AND PRIVATE HYDRANTS TO BE PAINTED SAFETY YELLOW WJSILVER CAPS AND OPERATING NUTS. 5. OPERATING NUTS ON HYDRANTS CONNECTED TO PUBLIC MAINS LARGER THAN 12" SHALL BE PAINTED BLACK.. CITY OF RALEIGH DEPARTMENT OF PUBLIC UTILITIES RALEIGH, GARNER, KNIGHTDALE, ROLESVILLE, WAKE FOREST, WENDELL * ZEBULON STANDARD FIRE HYDRANT WITH 5" 5TORZ PUMPER NOZZLE DWG, NO. REVISIONS I DATE REVISIONS DATE ABB 7-21-05 W-5 RRH DHL 2-18-08 REACTION BEARING AREAS POR HORIZONTAL WATER PIPE BENDS BASED ON TEST PRESSUREOf 200 P.S.I. "A" ALL AREAS GIVEN iN"SQUARE FEET. \ � Q� lo VJ NIF °° V Q `L // O 2 VO` G" G,_ I G11 P-411 P-71 2" 3/8" 20; - 24" I`-4" 1'-7" 3" 112" 1 I 1140 1,105 i ! i i 1 I 2 7/8" 22 1/20 2,207 1 2 2 1 1 1 3 1 O 450 j, 328 2 3 3 1 1 2 5 1 900 7,996 2 4 5 I ( 2 8 1 PLUG 5,455 2 3 4 I I 2 G 1 Bir 1 1 1/4a 1,970 1 1 2 1 1 1 2 1 22 1120 3,922 1' 2 3 1 1' 1 4 1 c)" 450 7,G94 2 4 5 I I: 2 8 1 900 14,215 4 8 9: 2 2 4 15 2 di PLUG 10,053 3 5 G 2 2 3 10 1 1211 C) 11 1/40 4,433 2 3 3 1 1 2 5 1 22 1,12-- 8,826 3, 5 G 2 2 3 9 1 u� 450 17,312 5 9 1 1 3 3 5 18 2. 900 31,053 8 1 G 19 4 4 8 32 4 PLUG 22,G 19 G 1 12 14 3 3 G 23 3 Gil 11 1140 7;681 2' 4 5 1 1 2 8 1 22 1/2" 1 5,491 4 8 I O 2 2 4 1 G 2; 450 30,779 8 1 G 19 4, 4' 8 3,1 4 901) 56,54 1 15 29 35' 8' t3 15 57 G PLUG 40,2131 10 21 25 5 5 10 1 41 5 REACTION BEARING AREAS ARE IN SQUARE FEET MEASURED IN A VERTICAL PLANE IN THE TRENCH SIDE AT AN ANGLE OF 900 TO THE THRUST VECTOR. USE 0'- 90 BEND VALUE FOR DWG, NO. HYDRANTS FOR ADDITIONAL SAFETY FACTOR. W- 1 O`. CITY OF RALEIGH DEPARTMENT,OF PUBLIC UTILITIES THRUST BLOCKING Df -SIGN QUANTITY TABLE 'REVISIONS DATE REVISIONS DATE W C 6-23-99 3" MIN. CLEARANCE THRUST COIL" Y1 REINFORCING REQUIREMENT'5 I.D. PIPE UBAR SIZE "X' BAK LENGTH "X' BAR WEIGHT `'i^' BAK LENGTH '"P' BAK WEIGHT NO, REQUIRED G" 30 #5: 21-211+ O.D. PIPE 1 .043 L35/I T I'-1" I. I 1-135. EACH X-24, v- 12 48" * greater I #G 3'-011+ O.D. PIPE' 1 .502 1-135/FT 1'-3" I a L55. EACH X-24, Y- 12 THRUST COLLAR AND THRUST SCHEDULE I.D, PIPE "A" "B" "C" "D' G,_ I G11 P-411 P-71 2" 3/8" 20; - 24" I`-4" 1'-7" 3" 112" 30 3G" P-4" " 1 '_71' 4 5/8" 48" $ cyeaLer I'-8" I'-9" 6" 7/8" NOTES I , SEE STANDARD DETAIL W-9 FOR THRUST BLOCK LOCATIONS. 2. CONCRETE SHALL BE 3000 PSI AND TRANSIT MIXED. 3. REINFORCING BARS SHALL BE DEFORMED AND TIED TOGETHER, 4. TRENCH BOTTOM WIDTH IN VICINITY OF THRUST BLOCK INSTALLATION SHALL BE THE MINIMUM WIDTH A5 SHOWN ON STANDARD DETAIL VV -3. 5, BACKFILL TAMPED IN G" LIFTS PER STANDARD DETAIL W-3, CITY C G. THRUST COLLAR MUST BE FACTORY DEPARTMENT C WELDED ON BOTH 51DES ALONG BOTH EDGES OF COLLAR AROUND THRUST BLOCKI CIRCUMFERENCE. FCR tA/ATFR VIAI z o � � cS) Q C) < _00 LL3z C) a q. • FINAL DRAWING - RELEASED FOR CONSTRUCTION CS us O 0 oma,\TNra,QO 0 z c)" CV di CV a m C) L u� u- 0 Rr t9 0.i 0 z 0 C) v : 0) N Q;2 Q > ul a-/ tLj E2 Q (0 Q s a Q C) Lu pj,_jus7_z 1 ��wO 0 C) p. rLu _ 0) CD z. mvl4 lu I Q Q � ZI< IQ z�� �Oo UO� �Ozc�� CD Z a;' a�> In Q7d:�UjOU tu p 0 C) w`- Lu z2L,? � __j oz �. Q�U I -- -Z v � � z IT, - �o zr Oout: 1u (o u _ (\j c() 'T if) ,de . p a! CITY OF RALEIGH 9 Q: DEPARTMENT OF PUBLIC UTILITIES STANDARD VERTICAL BEND DWG. NO REVISIONS DATE REVISIONS DATE W- 1 2ABB 4-G-04 J,P.S. I D. . L. G-1 6-08 M a v co . �N U �4 � 0 ZE c Q V VJ i,,llttltl///�' CAR 4680 :vO qN G• '��111/1i11 O � Q �w E -4 WLo owo� C) E--4 E l� P-4 0w 0 0 V� �r Psi Q U O WQz A w a w W z 0 V PROJECT NO. JPM-15010 FILENAME: JPM15010-D1 DESIGNED BY: N D W DRAWN BY: DLP SCALE: N.T.S. DATE: 04-04-2016 SHEET N0. _ °J MCADAMS q. • FINAL DRAWING - RELEASED FOR CONSTRUCTION M a v co . �N U �4 � 0 ZE c Q V VJ i,,llttltl///�' CAR 4680 :vO qN G• '��111/1i11 O � Q �w E -4 WLo owo� C) E--4 E l� P-4 0w 0 0 V� �r Psi Q U O WQz A w a w W z 0 V PROJECT NO. JPM-15010 FILENAME: JPM15010-D1 DESIGNED BY: N D W DRAWN BY: DLP SCALE: N.T.S. DATE: 04-04-2016 SHEET N0. _ °J MCADAMS U z 0 0 E 0 a 0 M X �Q0 �IN 9/ I G" OPERATION NUT I L2,500" 2 '1 /2" NATIONAL STANDARD OUTLET THREADS CITY OF RALEIGH DEPARTMENT OF PUBLIC UTILITIES HYDRANT 'OPERATING NUT AND 2 112" OUTLET TH READ5 DWG, NO, REVISIONS DATE REVISIONS I DATE vv- (.- RRH 3-31-00 DHL 2-18-08 A:B,B 14-13-041 J.P.S 1 1-1-1 O AND W I FOR, REACTION BLOCKING CONCRETE AREA. 3!4" ALL-TI1 READ STEEL ROC]. (CUT TO LENGTH) i',Q" M.J.- NIPPLE WITH GLANDS: (MIN;) GATE VALVE VALVE MAY BE BOLTED DIRECTLY TO, TEE.:. 24" 6' 30" 8 36" 8 NOTES. 1. STEEL RODS AND BOLTS SHALL BE 314' I -10T DIPPED GALVANIZED.. 2, SEE STANDARD THRU`aT BLOCK. TABLES W-10 AND W-1 .I FOR CONCR>rJ'E.. 3. CONCRETE SMALL NOT CONTACT ALTS OR ENDS OF MECHANICAL FITTINGS. 4, THIS RODDING REQUIREMENT DOES- NOT APPLY TO FIRE HYDRANTS, flap 4 1� .•( v 4 • .� d !a 3000 PSI SOLID CONCRETE SHALL BE USED AS FOOTING` FOR DUCTILE IRON PIPE: b � p ,G7 d TAPPINGSCEEVE" APPROVED METHOD FOR EXTENSION OF VALVE BOX NOT[: 2'x 2k 6" CONCRETE PAD REQUIRED ON ALL FLANGE GATE /TAPPING VALVE TOP` VIEW VALVE. M.J. VIEW NOTES: i .CONCRETE_ SHALL NOT CONTACT BOLTS- OR ENDS 0"r MECHANICAL JOINT FITTINGS. 2. SEE. STANDARD REACTION BLOCK TABLES, W- 10 AND Vi/- I I FOR AREA OF CONCRETE REQUIRED. _FITTING !2"-5 Slb"dam 6 m. 7 5!8 VALVES. NO PRECAST CONCRETE DOUGHNUT �gyz� ALLOWED. 6" s° 5 1 "-8 112" SEE STANDARD W- 15 °103 2' FOR COVER DETAILS. Cq It, STANDARD VALVE BOX TOP SECTION TO 1-1 2' 1110- DOMESTIC' BE SLIDE SECTION CASTING FINAL PAVEMENT COURSE • d` @' VALVE BOX a•Q a DOVER CONCRETE - • PAD - VALVE ' BOX USE 5° 501E PIPE :FOR EXTENSIONS TAMPED ,CA BACKFILL - - WATER VALVEG. MAI N STAB -IN C.I. OR D.I. . PIPE GASKET TAMPED _ - BACKFILL • NOTES: I) VALVE BOXNOT TO CONTACT WATER MAIN r+ll 2) ALL 7RAPPICCASTINGS MUST 6E CLA95 35' OR GREATER. 3) FOR ANY VALVES OVER 101 DEEP, A VALVE STEM EXTENSION MUST BE USED TO BRING TO A DEPTH Of NO MORE THAN 5', EXTENSION MUST BE A MINIMUM Of I" SOIJD STOCr, STANDARD VALVE BOX 4) TOTAL VALVE BOX WEIGHT; MINIMUM OF 85 LBS. BOTTOM SECTION NOTE I - "WATER" LETTERING .MUST BE I" RAISED RECESSED FLUSH SECTION VIEW (. ) NOTE 2 -VALVE COVER SHALL BE DOMESTICALLY CAST, NOTE 3 - COVER MUST HAVE.A MINIMUM WEIGHT OF 25 POUNDS:. -NOTE 4 - COVER MUST BE GLASS 35 OR GREATER. (VOTE 5 -COVER MUST MEET OR EXCEED AASHTO'H-20 LOAD REQUIREMENTS. CITY OF RALEIGH DEPARTMENT OF PUBLIC UTILITIES 5 114" VALVE -`BOX DROP LTD WITH, WATER METER 1 SECTION C m 0 r-, CITY SEAL J f111_ o z N A Y to vi z. U.S)- tom-. zQ W Q 'o z� o i .8":CPRE-DRILLED HOL;r. � o to U COs CO d � o �c Q tL �O m z0�cv.sQ. o o O 0 0� _ tt, ,o z f- a, x � U j (� Q ! lu ' 3 o O �G w w: Q uUr O -�-+ Q L Q Q U Q- .r' z usQ� O w Q Q zw� T- d=U > o�G w � Q �O� LL z (s) w� - aa10 n 3" f- z 0 o o LLMC, ' 18" d tu Z LU Q 2q„ t� Iu CL - 0 z=C tu Lu o w >mw �(V tL- Q O CITY OF RALEIGH r 0 1- DEPARTMENT OF PUBLIC UTILITIES ONE OR TWO FAMILY DWELLINGS 15ACKFLOW PREVENTION/ METER ASSEMBLY INSTALLATION, DVVG. NO. REVISIONS DATE REV15IONS DATE'< :W-24 Y C,A. 12-31-91 D.H L, A.B.B. 4-7-04 J.f':5, 1 I/4110 AND W I FOR, REACTION BLOCKING CONCRETE AREA. 3!4" ALL-TI1 READ STEEL ROC]. (CUT TO LENGTH) i',Q" M.J.- NIPPLE WITH GLANDS: (MIN;) GATE VALVE VALVE MAY BE BOLTED DIRECTLY TO, TEE.:. 24" 6' 30" 8 36" 8 NOTES. 1. STEEL RODS AND BOLTS SHALL BE 314' I -10T DIPPED GALVANIZED.. 2, SEE STANDARD THRU`aT BLOCK. TABLES W-10 AND W-1 .I FOR CONCR>rJ'E.. 3. CONCRETE SMALL NOT CONTACT ALTS OR ENDS OF MECHANICAL FITTINGS. 4, THIS RODDING REQUIREMENT DOES- NOT APPLY TO FIRE HYDRANTS, flap 4 1� .•( v 4 • .� d !a 3000 PSI SOLID CONCRETE SHALL BE USED AS FOOTING` FOR DUCTILE IRON PIPE: b � p ,G7 d TAPPINGSCEEVE" APPROVED METHOD FOR EXTENSION OF VALVE BOX NOT[: 2'x 2k 6" CONCRETE PAD REQUIRED ON ALL FLANGE GATE /TAPPING VALVE TOP` VIEW VALVE. M.J. VIEW NOTES: i .CONCRETE_ SHALL NOT CONTACT BOLTS- OR ENDS 0"r MECHANICAL JOINT FITTINGS. 2. SEE. STANDARD REACTION BLOCK TABLES, W- 10 AND Vi/- I I FOR AREA OF CONCRETE REQUIRED. _FITTING !2"-5 Slb"dam 6 m. 7 5!8 VALVES. NO PRECAST CONCRETE DOUGHNUT �gyz� ALLOWED. 6" s° 5 1 "-8 112" SEE STANDARD W- 15 °103 2' FOR COVER DETAILS. Cq It, STANDARD VALVE BOX TOP SECTION TO 1-1 2' 1110- DOMESTIC' BE SLIDE SECTION CASTING FINAL PAVEMENT COURSE • d` @' VALVE BOX a•Q a DOVER CONCRETE - • PAD - VALVE ' BOX USE 5° 501E PIPE :FOR EXTENSIONS TAMPED ,CA BACKFILL - - WATER VALVEG. MAI N STAB -IN C.I. OR D.I. . PIPE GASKET TAMPED _ - BACKFILL • NOTES: I) VALVE BOXNOT TO CONTACT WATER MAIN r+ll 2) ALL 7RAPPICCASTINGS MUST 6E CLA95 35' OR GREATER. 3) FOR ANY VALVES OVER 101 DEEP, A VALVE STEM EXTENSION MUST BE USED TO BRING TO A DEPTH Of NO MORE THAN 5', EXTENSION MUST BE A MINIMUM Of I" SOIJD STOCr, STANDARD VALVE BOX 4) TOTAL VALVE BOX WEIGHT; MINIMUM OF 85 LBS. BOTTOM SECTION NOTE I - "WATER" LETTERING .MUST BE I" RAISED RECESSED FLUSH SECTION VIEW (. ) NOTE 2 -VALVE COVER SHALL BE DOMESTICALLY CAST, NOTE 3 - COVER MUST HAVE.A MINIMUM WEIGHT OF 25 POUNDS:. -NOTE 4 - COVER MUST BE GLASS 35 OR GREATER. (VOTE 5 -COVER MUST MEET OR EXCEED AASHTO'H-20 LOAD REQUIREMENTS. CITY OF RALEIGH DEPARTMENT OF PUBLIC UTILITIES 5 114" VALVE -`BOX DROP LTD WITH, WATER METER 1 SECTION C m 0 r-, CITY SEAL J J z A vi W Q i .8":CPRE-DRILLED HOL;r. CO d Q tL �O o O � _ tt, ,o AND W I FOR, REACTION BLOCKING CONCRETE AREA. 3!4" ALL-TI1 READ STEEL ROC]. (CUT TO LENGTH) i',Q" M.J.- NIPPLE WITH GLANDS: (MIN;) GATE VALVE VALVE MAY BE BOLTED DIRECTLY TO, TEE.:. 24" 6' 30" 8 36" 8 NOTES. 1. STEEL RODS AND BOLTS SHALL BE 314' I -10T DIPPED GALVANIZED.. 2, SEE STANDARD THRU`aT BLOCK. TABLES W-10 AND W-1 .I FOR CONCR>rJ'E.. 3. CONCRETE SMALL NOT CONTACT ALTS OR ENDS OF MECHANICAL FITTINGS. 4, THIS RODDING REQUIREMENT DOES- NOT APPLY TO FIRE HYDRANTS, flap 4 1� .•( v 4 • .� d !a 3000 PSI SOLID CONCRETE SHALL BE USED AS FOOTING` FOR DUCTILE IRON PIPE: b � p ,G7 d TAPPINGSCEEVE" APPROVED METHOD FOR EXTENSION OF VALVE BOX NOT[: 2'x 2k 6" CONCRETE PAD REQUIRED ON ALL FLANGE GATE /TAPPING VALVE TOP` VIEW VALVE. M.J. VIEW NOTES: i .CONCRETE_ SHALL NOT CONTACT BOLTS- OR ENDS 0"r MECHANICAL JOINT FITTINGS. 2. SEE. STANDARD REACTION BLOCK TABLES, W- 10 AND Vi/- I I FOR AREA OF CONCRETE REQUIRED. _FITTING !2"-5 Slb"dam 6 m. 7 5!8 VALVES. NO PRECAST CONCRETE DOUGHNUT �gyz� ALLOWED. 6" s° 5 1 "-8 112" SEE STANDARD W- 15 °103 2' FOR COVER DETAILS. Cq It, STANDARD VALVE BOX TOP SECTION TO 1-1 2' 1110- DOMESTIC' BE SLIDE SECTION CASTING FINAL PAVEMENT COURSE • d` @' VALVE BOX a•Q a DOVER CONCRETE - • PAD - VALVE ' BOX USE 5° 501E PIPE :FOR EXTENSIONS TAMPED ,CA BACKFILL - - WATER VALVEG. MAI N STAB -IN C.I. OR D.I. . PIPE GASKET TAMPED _ - BACKFILL • NOTES: I) VALVE BOXNOT TO CONTACT WATER MAIN r+ll 2) ALL 7RAPPICCASTINGS MUST 6E CLA95 35' OR GREATER. 3) FOR ANY VALVES OVER 101 DEEP, A VALVE STEM EXTENSION MUST BE USED TO BRING TO A DEPTH Of NO MORE THAN 5', EXTENSION MUST BE A MINIMUM Of I" SOIJD STOCr, STANDARD VALVE BOX 4) TOTAL VALVE BOX WEIGHT; MINIMUM OF 85 LBS. BOTTOM SECTION NOTE I - "WATER" LETTERING .MUST BE I" RAISED RECESSED FLUSH SECTION VIEW (. ) NOTE 2 -VALVE COVER SHALL BE DOMESTICALLY CAST, NOTE 3 - COVER MUST HAVE.A MINIMUM WEIGHT OF 25 POUNDS:. -NOTE 4 - COVER MUST BE GLASS 35 OR GREATER. (VOTE 5 -COVER MUST MEET OR EXCEED AASHTO'H-20 LOAD REQUIREMENTS. CITY OF RALEIGH DEPARTMENT OF PUBLIC UTILITIES 5 114" VALVE -`BOX DROP LTD WITH, WATER METER 1 SECTION C m 0 r-, CITY SEAL J J z A vi W Q i .8":CPRE-DRILLED HOL;r. -z 1.75° :METER 19 1f4"— 4" SKIRT co co T—T fJ� QJ SECTION E3 -E3 -C NOTES; I .COVER WEIGHT;. 13 -LBS +1-- 5% 2. LIDS TO BE COATED WITH BITUMINOUS COAL TAR COATING 3. BOXES AND LIDS MUSTBE MANUFACTURED: FROM SAME DOMESTIC FOUNDRY. 1y FINAL DRAW ING - RELEASED FOR CONSTRUCTION co p M O '4z® VJ L - - 680 = /llilllf►%� z 0 to a Q aQ a� w lC� � W co co z CIO 0-4 E--4 a a Ow � O V J V Q N A 1 O Waz A w W Q V PROJECT No. JPM-15010 Fn.ENAmE: JPM15010-D1 DESIGNED BY: N D W DRAWN BY: DLP scaLE: N.T.S. DATE: 04-04-2016 SHEET No. ,= McAD AIVss U z c °m E `3 0- 00 00 00 R 0 i 0 0 to CL FINISHED GRADE j FINAL UNDISTURBED SOIL BACKFILL INITIAL BACKFILL ° o MINI 51D, E 1NNWHEN7ROCKNB//,/,I C" O;D. OF PIPE G" ~ MUM CLEARANCE ENCOUNTERED I2" 10 D. OF PIPE 1 '-.q-.__MAXIMUM SIDE CLEARANCE NOTES: 1 TRENCHES REQUIRING SHORING AND BRACING'; DIMEN51ON5 SHALL 15E TAKEN FROM THETNSIDF FACE OF THE SHORING AND BRACING 2. NO ROCKS OR BOULDERS 4" OR LARGER TO BE USED IN INITIAL BACKFILL. 3. ALL BACKFILL MATERIAL SHALL BE SUITABLE NATIVE MATERIAL. r 4• BACKFILL SMALL BE PED IN LIFTS I': TRAFFIC AREAS, 1 N NON -TRAFFIC AREAS. K t-( M 6 N R R . 2 1 5. ACHIEVE 80% COMPACTION IN NON -TRAFFIC AREAS,, AND 957. COMPACTION INT � F_FIC AREAS. G. IF IN EASEMENT 4 TOPSOIL, AND i2 CLEPN-5ELECT FILL MAYBE REQUIRED; 7. NO BOULDER5 8" IN DIAMETER. OK'GREATER ALLOWED IN FINAL BACKFILL. CITY OF RALEIGH DEPARTMENT OF PUBLIC UTILITIES TRENCH BOTTOM DIMENSIONS .$ BACKFILLING REQUIREMENTS FOR DUCTILE IRON DWG- NO. REVISIONS DATE REVISIONS DATE D.W.C. 9-3-99 5-4 RRH 3 30-00 COVER 120 L55. MINIMUM MANHOLE FRAME AND COVER P, O N F N yF lC 1 y A F R MI T R D � C'E d 23 112" 2 1' 0 f 5z� o ll S�'ACEQ O 2 3/4" I " VENT HOLE 25 I/1 G" 23.1 1116" I, 7 J/2" 1 22 BUTYL-NEK OR APPROVED SEALANT BETWEEN FRAME AND COVER I 25 15/1 G" 33 1 !4" NOTES: 5/8"X3" LAGSHIELD IN HOLE 1) ALL MANHOLE FRAMES SHALL BE DRILLED INTO CONE OR DOMESTICALLY CAST. RING WITH ANCHOR SUNK TO 2) FRAME SHALL BE A MINIMUM WEIGHT OF DESIGN DEPTH, AND 3fi5"X3" 182 LES. 100THIN PUBLIC ROLA" fiND 1 60 L35. HOT DIPPED GALVANIZED WITHIN EASEMENTS. LAG BOLT AND WASHER. 3) COVER SHALL WEIGH A MIN. OF 120 LBS. 4) ALL MANHOLE FPAME5 OUTSIDE OF PAVED 5URFACES SHALL BE BOLTED TO THE CONE CITY OF RALEIGH SECTION OK KING WI1 H AMINIMUM OF 4 DEPARTMENT OF PUBLIC UTILITIES BOLTS PER FPAME. FINISHED GRADE FINAL BACKFILL f ND(STURBED SOIL TYPICAL TUNCH BOTTOM DIMEN51ON5 fOR SDh 35 PVC GRAVITY PIPE NOTES I .FORTRENCH E5 REQU,I RING SHOKINGAND BRACING, DIMENSIONSSHALL BETALKENFROM' TH E c �- INSIDE PACE OF THE SHORING AND BRACING. 50 BOULDERS 2 NO ROCK R BOU ER OR:ELARGER :4 BE USED ED W WTAL BAC F ILL 3 ALL BACKFILL MATERIAL SHALL BSUITABLE NATIVE MATERIAL. 4, BACKFILL SHALL BE TAMPED IN G" LIFTS IN TRAFFIC AREAS, 1 2" 'IN NON -TRAFFIC. AREAS. 4 e � 41 T © SAgCE Qp pp 2'-0" b Q v Q 3000 P.5.I. CONCRETE ENCASEMENT 4.' ADJUST FLUSH PLAN WITH FINAL GRADE STANDARD MANHOLE FRAME AND COVER •d A•-• •d': Dp�a:�Q p ••.t - e. Q Q' - r A_ B.C. STANDARD ' MANHOLE COMPACTED BACKF1 LL / TOTAL / CHIMNEY NOT TO EXCEED I P, 5ECTION PRECAST CONCRETE SPACER (DONUT RINGS) IN TRAFFIC AREAS ONLY, DONUT RINGS- NOT ALLOWED IN EASEMENTS. 5EE C.O.R. 5TANDARD 5-25 FOR MANHOLE FRAME AND COVER- *: NEW MANHOLES U5E A BUTYL 5EALANT BETWEEN FRAME AND MANHOLE TOP 5ECTION WHEN 5ECURING FRAME TO MANHOLE TO ROVIDE A WATER TIGHT 5EAL. 2'-O" ► • ` 24" MAX n Q, A P , ° ECCENTRIC M.H. CONE Q ► . MAY BE U5ED ON 8" , 10" AND 12" 5EWER MAIN 5- 7 .' MANHOLE CONE AND BARREL 5ECTION5.5HALL * BE A5 PER ASTM. 5TANDARD5 •.A 4' -G' -DIA. A5 � -P 't4 REQUIRED p: s. Lu *� �• o "O"IRING SEAL 4 ` } OR RAM -NECK I All SHELF �. 9 ; � RUBBER 1300T SLOPE p,a •Q = °�,. LATERAL INVERT 5HALL NOT BE GO, " 'P ' '° ' Q . LOWER THAN MAIN SPRING - Q ''> :} 4 , Q LINE. MANHOLE SHALL BE 2' `:� • : e � �, 4 � • G., ABOVE 100 YEAR FLOOD PLAIN r OR SEALED AND VENT TO BE 2' ABOVE 100 YEAR FLOOD 9, PLAIN. WHEN MANHOLE TOPS )O ARE IN EXCE55 OF 3' ABOVE GRADE. OUT5IDE 5TEP5 MUST BE PROVIDED. SEE 5TANDARD 5-28 FOR:5TEP DETAIL. IN NON TRAFFIC AREA5, TOP OF FRAME AND COVER.5HALL 6E IN5TALLED A MIN. OF I' ABO E V A FINISHED GROUND SURFACE 5EE 1 _' N. 5 EWER DE G 5. SECTION MIN, 9" COMPACTED #G7 5TONE BA5E TO BE IN5TALLED UNDER NEW MANHOLE. CITY OF RALEIGH DEPARTMENT OF PUBLIC UTILITIE5 5TANDARD PRECAST 5ANITARY 5EWER MANHOLE Y,C_A. \\ � � Cid a% _ INITIAL BACKFILL z '�L0 tOm. no'? " SPRING LINE fi \\,;. Ed UO d=W —i "Il� z n1 #G7 STONE Z W Q U op a t1AUNCHING o °� ° ° C) u� ° o ° o ° ° PIPE GRADE L, d o ° o O a 0 0 O °oAI,D° 00, 4.. BEDDING 0- LL4 djU Q t w IL j ? z :Lu Q U %` O tf i MINIMUM SIDE TAMP WELL UNDER G� - 6" O.D. OF PIPE -'�"'� CLEARANCE C BOTTOM HALF OF PIPE o�,��z s� y �, O O TYPICAL TUNCH BOTTOM DIMEN51ON5 fOR SDh 35 PVC GRAVITY PIPE NOTES I .FORTRENCH E5 REQU,I RING SHOKINGAND BRACING, DIMENSIONSSHALL BETALKENFROM' TH E c �- INSIDE PACE OF THE SHORING AND BRACING. 50 BOULDERS 2 NO ROCK R BOU ER OR:ELARGER :4 BE USED ED W WTAL BAC F ILL 3 ALL BACKFILL MATERIAL SHALL BSUITABLE NATIVE MATERIAL. 4, BACKFILL SHALL BE TAMPED IN G" LIFTS IN TRAFFIC AREAS, 1 2" 'IN NON -TRAFFIC. AREAS. 4 e � 41 T © SAgCE Qp pp 2'-0" b Q v Q 3000 P.5.I. CONCRETE ENCASEMENT 4.' ADJUST FLUSH PLAN WITH FINAL GRADE STANDARD MANHOLE FRAME AND COVER •d A•-• •d': Dp�a:�Q p ••.t - e. Q Q' - r A_ B.C. STANDARD ' MANHOLE COMPACTED BACKF1 LL / TOTAL / CHIMNEY NOT TO EXCEED I P, 5ECTION PRECAST CONCRETE SPACER (DONUT RINGS) IN TRAFFIC AREAS ONLY, DONUT RINGS- NOT ALLOWED IN EASEMENTS. 5EE C.O.R. 5TANDARD 5-25 FOR MANHOLE FRAME AND COVER- *: NEW MANHOLES U5E A BUTYL 5EALANT BETWEEN FRAME AND MANHOLE TOP 5ECTION WHEN 5ECURING FRAME TO MANHOLE TO ROVIDE A WATER TIGHT 5EAL. 2'-O" ► • ` 24" MAX n Q, A P , ° ECCENTRIC M.H. CONE Q ► . MAY BE U5ED ON 8" , 10" AND 12" 5EWER MAIN 5- 7 .' MANHOLE CONE AND BARREL 5ECTION5.5HALL * BE A5 PER ASTM. 5TANDARD5 •.A 4' -G' -DIA. A5 � -P 't4 REQUIRED p: s. Lu *� �• o "O"IRING SEAL 4 ` } OR RAM -NECK I All SHELF �. 9 ; � RUBBER 1300T SLOPE p,a •Q = °�,. LATERAL INVERT 5HALL NOT BE GO, " 'P ' '° ' Q . LOWER THAN MAIN SPRING - Q ''> :} 4 , Q LINE. MANHOLE SHALL BE 2' `:� • : e � �, 4 � • G., ABOVE 100 YEAR FLOOD PLAIN r OR SEALED AND VENT TO BE 2' ABOVE 100 YEAR FLOOD 9, PLAIN. WHEN MANHOLE TOPS )O ARE IN EXCE55 OF 3' ABOVE GRADE. OUT5IDE 5TEP5 MUST BE PROVIDED. SEE 5TANDARD 5-28 FOR:5TEP DETAIL. IN NON TRAFFIC AREA5, TOP OF FRAME AND COVER.5HALL 6E IN5TALLED A MIN. OF I' ABO E V A FINISHED GROUND SURFACE 5EE 1 _' N. 5 EWER DE G 5. SECTION MIN, 9" COMPACTED #G7 5TONE BA5E TO BE IN5TALLED UNDER NEW MANHOLE. CITY OF RALEIGH DEPARTMENT OF PUBLIC UTILITIE5 5TANDARD PRECAST 5ANITARY 5EWER MANHOLE Y,C_A. z' O D- o i - z ti_.I tu Q U .o: z � LLI ts�s,c-' v� O>nQ d� z o cr dw�z U� ➢4.vn LL ,s O ,u�<(d zz O a "i Lu Uuaz (sy - I- U S7 ^+ tLt u z ttl d d CD_, ddz O wZ �/" <t -wd w Q F- (n us Z U t`s > x Q� Q = � = 's c5 s LQ �Q�� rU- v Quote �o a - U na� 61O Fd sty d. N � Z Eil" Z ~ �- d [Y- t- f- oma] !2" Lu z> Z _ LE G C) U-1 ngn OOU LL-- Qz t -Q "---" Z z LL- u n U ; Q = Z ups aa-- LL'cn E C� m Ci p w Q < z' LL- LU LU C = z Q a7 Q _ - � q,' L-1 m t� a, :2 Q_zED wcsl a!O 2 0 < 0 L I -- w U i- F CLL¢ :20n Lu w O Lu fiC O v Q CITY OF RALEIGH DEPARTMENT OF PUBLIC. UTILITIES w u TYPICAL 5ANITARY 5EWEP, Q Q LATERAL CONNECTION n is DING- NO. REVI5ION5 DATE REV1510N5 DATE N O �_3� Y:C.A. G-92_ A.B.B. 4 -0 RRH 3=30-00 D,H.L, I G -18 -08 - PLASTIC 8-08 PLASTIC GREEN MANHOLE MIARKER-LABELED SEWER MANHOLE, SEE NOTES TEST -STATION OR TEST "PORT - IFSTANDARD H2O TRAFFIC LOAD RATED VALVE BOX WITH LID LABELED "T5" AND: PAINTED GREEN, PLACED ABOVE LOOP 3 FT (MIN) DOWNSTREAM SEWER OF WIRE INTO TEST STATION - - EXISIING GRADE STANDARD.INDUSTRIAL (SIMILAR META), TYP I� I2 HOLE \� FILLED WTH Q NO. 12 GAUGE I ( ( r 'z SOLID BARD ( ( I' CONCRETE Hu COPPER TRACER W1 RE, TYP 1 ( SEWERtu 1 E/ WRAP TRACER I ( LATERAL WIRE AROUND I I I) SEE CIRCUMFERENCE OF 1 I I 1 NOTE 2 I MAN SPLIC HOLE AND E i SEWER TO TRACER WIRE FOR 1 I ( I SADDLE DOWNSTREAM SEWER 1 I I ) TAP MAIN 1 ------r -- { l FLOW ( I L I IF - -II l /Y ( I I I 0 A `---- -i 1-----------t-1-- - L — — — — J SEWER. NOTES: MAIN I . THE TRACER WIRE SHALL BE CONTINUOUS TO THE GREATE5T EXTENT POSSIBLE. FOR GRAVITY MAIN AND OR LATERA INSTALLATIONS LESS THAN 8 FT, THE TRACING WIRE SHALL DE ATTACHED TO THE PIPE, TRACER WIRE SHALL BE LAID FLAT AND SECURELY AFFIXED TO THE PIPE AT 10 FOOT INTERVALS. FOR GRAVITY MAIN AND ORLATERAL INSTALLATION DEEPER'THAN 8.FT 'rHE TRACING WIRE SHALL BE INSTALLED AT A DEPTH OF 7-8 FT."THE WIRE SHALL BE PROTECTED FROM DAMAGE DURING THE MCUTION OF THE WORK. NOBREAKS OF CUTS IN THE TRACER WIRE SHALL BE PERMITTED. 2, WHERE LATERAL TAPS ARE MADE BY`SERVICE SADDLES, THE TRACER WIRE SHALL NOT BE ALLOWED TO TO BE PLACED BETWEEN THE SADDLE AND MAIN. 3 MANHOLE MARKERS SHALL BE PLACED ADJACENT TO MANHOLES AT THE DISCRETION OF OWNER OR OWNER'S REPRESENTATIVE. _ _ \\ � � Cid a% z '�L0 tOm. fi \\,;. Ed UO d=W —i "Il� z n1 Z W Q U a �a u1 rC3z.U- �, C) u� z F- 1.\� Oz=�,- d� t Ot`{ i�U' - L, d d su CL/ 0�. 0- LL4 djU Q t w IL j ? z :Lu Q U %` O tf i = Cy �' F- u o�,��z s� y �, O O _ - a O U d i ryQM Nil Lu 41 �" • IQ W\�) - 111\x\\\ ,_ Q Lu > Q to d O u., LL- till �° CL Q a1I\\�� b�°n O W G� a cS) Q p 4 0Utu U -j > T7 w CIN u4 O� z z' O D- o i - z ti_.I tu Q U .o: z � LLI ts�s,c-' v� O>nQ d� z o cr dw�z U� ➢4.vn LL ,s O ,u�<(d zz O a "i Lu Uuaz (sy - I- U S7 ^+ tLt u z ttl d d CD_, ddz O wZ �/" <t -wd w Q F- (n us Z U t`s > x Q� Q = � = 's c5 s LQ �Q�� rU- v Quote �o a - U na� 61O Fd sty d. N � Z Eil" Z ~ �- d [Y- t- f- oma] !2" Lu z> Z _ LE G C) U-1 ngn OOU LL-- Qz t -Q "---" Z z LL- u n U ; Q = Z ups aa-- LL'cn E C� m Ci p w Q < z' LL- LU LU C = z Q a7 Q _ - � q,' L-1 m t� a, :2 Q_zED wcsl a!O 2 0 < 0 L I -- w U i- F CLL¢ :20n Lu w O Lu fiC O v Q CITY OF RALEIGH DEPARTMENT OF PUBLIC. UTILITIES w u TYPICAL 5ANITARY 5EWEP, Q Q LATERAL CONNECTION n is DING- NO. REVI5ION5 DATE REV1510N5 DATE N O �_3� Y:C.A. G-92_ A.B.B. 4 -0 RRH 3=30-00 D,H.L, I G -18 -08 - PLASTIC 8-08 PLASTIC GREEN MANHOLE MIARKER-LABELED SEWER MANHOLE, SEE NOTES TEST -STATION OR TEST "PORT - IFSTANDARD H2O TRAFFIC LOAD RATED VALVE BOX WITH LID LABELED "T5" AND: PAINTED GREEN, PLACED ABOVE LOOP 3 FT (MIN) DOWNSTREAM SEWER OF WIRE INTO TEST STATION - - EXISIING GRADE STANDARD.INDUSTRIAL (SIMILAR META), TYP I� I2 HOLE \� FILLED WTH Q NO. 12 GAUGE I ( ( r 'z SOLID BARD ( ( I' CONCRETE Hu COPPER TRACER W1 RE, TYP 1 ( SEWERtu 1 E/ WRAP TRACER I ( LATERAL WIRE AROUND I I I) SEE CIRCUMFERENCE OF 1 I I 1 NOTE 2 I MAN SPLIC HOLE AND E i SEWER TO TRACER WIRE FOR 1 I ( I SADDLE DOWNSTREAM SEWER 1 I I ) TAP MAIN 1 ------r -- { l FLOW ( I L I IF - -II l /Y ( I I I 0 A `---- -i 1-----------t-1-- - L — — — — J SEWER. NOTES: MAIN I . THE TRACER WIRE SHALL BE CONTINUOUS TO THE GREATE5T EXTENT POSSIBLE. FOR GRAVITY MAIN AND OR LATERA INSTALLATIONS LESS THAN 8 FT, THE TRACING WIRE SHALL DE ATTACHED TO THE PIPE, TRACER WIRE SHALL BE LAID FLAT AND SECURELY AFFIXED TO THE PIPE AT 10 FOOT INTERVALS. FOR GRAVITY MAIN AND ORLATERAL INSTALLATION DEEPER'THAN 8.FT 'rHE TRACING WIRE SHALL BE INSTALLED AT A DEPTH OF 7-8 FT."THE WIRE SHALL BE PROTECTED FROM DAMAGE DURING THE MCUTION OF THE WORK. NOBREAKS OF CUTS IN THE TRACER WIRE SHALL BE PERMITTED. 2, WHERE LATERAL TAPS ARE MADE BY`SERVICE SADDLES, THE TRACER WIRE SHALL NOT BE ALLOWED TO TO BE PLACED BETWEEN THE SADDLE AND MAIN. 3 MANHOLE MARKERS SHALL BE PLACED ADJACENT TO MANHOLES AT THE DISCRETION OF OWNER OR OWNER'S REPRESENTATIVE. _ _ �.. /-3 S/1?-tc,, FINAL DRAWING - RELEASED FOR CONSTRUCTION M �C4 co U � A 0 � w a �� z p Xz� c h Mona 0.111111111 1#'t CSR Z) .2 S "9 6 0 v O rn W Q aQ w t� Z LO w FM z 0 wE-4�Z Aon 0-4 E--4 AW, 0 W o yv1 cq A F� F-1 W V z w Vi F-1 �► 0 u PROJECT NO. JPM-15010 FII.ENAME: JPM15010-D1 DESIGNED BY: N D W DRAWN BY: DLP SCALE: N.T.S. DATE: 04-04-2016 SHEET NO. _ MJ MCADAMS �; II O 2. 4L:& _ \ Q is o `qy" ,0 9NI1Lu 41 �" IQ � �U. a >� Qo\411\� IoW IQ UOQ �1\�41\ - CD v Q Q a1I\\�� b�°n O G� a cS) Q p 4 0Utu Lu 0J y� lu t U o p --+ U O� z O w a� I ' usrv.. m� r- y us z CD o4. tu 90 CL/ .CO ' d O (n Com,) l0- tf)C-/ 4 Q 0- 9- CEz- <u ' iOs O usd:f C > w usD OO z U z z Id -d us D - s :ua '�luLLJ uj �_ X'D =0,2�0a t'' A-/ usuus z C7 u�ytu U �, ztu U3.cn � '[ � Q. oC to 0) �0 U u -j t° Um U d t O. .=Q WQ"pf wflw nC0�/ >iS U w rJ t � O us U-4 tZ �-luQ - o° oz ul tnus2 ` amus p fit= (3 QO a szz c �y ZU-3 mu and �z �- o.Q� oU,� ��X lu <,, - (3) lu(3)�Fr:��'_ z' 1E ) Vo u�Q�UQ (slu usUusz =z �� 0 < Q0 021 QFL/d uUsd��waC lu us z Ir s- Ch z 'z CITY OF RALEIGH 'z us i-- us D t- us us 0 w O = ° Q Ov Q t9 O cSi DEPARTMENT OF PUBLIC UTILITIES u c� Q°au��0Dus0 lu TYPICAL SANITAF:YSEWER ususoOus0Zn QQ—/0(D -r=oma=0zlun-0Z LATERAL TRACER WIRE z r a¢ m to a u d us DWG. NO. REVISIONS DATE REVISIONS- DATE (V th CJ -SQA WKD 9- 14 �.. /-3 S/1?-tc,, FINAL DRAWING - RELEASED FOR CONSTRUCTION M �C4 co U � A 0 � w a �� z p Xz� c h Mona 0.111111111 1#'t CSR Z) .2 S "9 6 0 v O rn W Q aQ w t� Z LO w FM z 0 wE-4�Z Aon 0-4 E--4 AW, 0 W o yv1 cq A F� F-1 W V z w Vi F-1 �► 0 u PROJECT NO. JPM-15010 FII.ENAME: JPM15010-D1 DESIGNED BY: N D W DRAWN BY: DLP SCALE: N.T.S. DATE: 04-04-2016 SHEET NO. _ MJ MCADAMS w FVC, TO P-1; ,PIPE ADAFTEK USE IFERNCQ COUPLING 445-40POR APPROVED EQUAL TO SEAL. 45' PVC SADDLE PIPE CROWN� BACKFILL UNDER PVC SADDLE, ADAPTOR, AND CAST IRON BEND WITH#G7 STONE, AS SHOWN ON 5-4. SADDLE INSTALLATION LIMITS Odd SPRINGLINE =1 4.00" STANDARD 4" BRONZE CLEANOUT "PLUG CLEANOUT FERRULE WITH PLUG STYLES ACCEPTED,: INVERTED NUT RAISED NUT CITY OF: RALEIGH --DEPAUMENTIO,f PUBLIC UTILITIES 4",CLEANOUT PLUG D\/VG. NO., REVISIONS DATE REVISIONS DAT RRH 3-30-00 5-34 1 1 U.W.C. /-&t5l A o Q < Nr o z 0, lz IL oc� Q to q od, oC Z 0 ED a Lu wid Z' lu < 0 lu, 0 �10 CY u. 0: c� bTY OF RALEIGH T) z I— DEFAKTMENT OF PUBLIC UTILITIES, lu 2 o< z 0 LATERAL SADDLE IN5TALLATION, DETAIL < MR VCP AND'DUCTILE -IRON PIPE DING, NO,, REVISIONS DATE, 1, REVISIONS DATE ,5-3:2 3-1-57 3-1-57 RRH, 3-30-001 PLAN 5ECTION A - A #3 OR, #4 REBAR CORROSION RESISTANT MATERIAL RUBBER, PLASTIC - 46 cl SIDE ELEVATION TYPICALSANITAKY SEWER ,SERVICE .BACKWATER VALVE STYLES: FLAPPER VALVE TYPICAL BACKWATER VALVE INSTALLATIONS: 4- 1 " DIA HOLE5 @ I MINIMUM AIG 4VEIG11T FRAME 152 COVER I GO TOTAL 342 (2) LIFTING 13AR5 0 0 I "w 0 0 III LETTERING RECESSED FLUSH PLAN 25 1/41' 2G 1/4" 17! --T 7 112" GASKET IN I VERTICAL 22" PAGE F COVER KING MUST BE - 28" ANCHORED IN — 34" ACCORDANCE MTH S-25 5/6" o/ —STAINLESS STEEL ROD TYPICAL LIFTING DEVICE SECTION A CITY OF RALEIGH DEPARTMENT _OF PUBLIC UTILITIES MANHOLE FRAME AND WATERTIGHT COVER DWG. NO. >REVISIONS -DATE REVISIONS DATE 5-2G 3-1-67 18-1-57 ADD 5-29-051 P\kH 13-30-001 D, H. L. 61 1810"8 1 BUILDING WITH NEXT UPSTREAM MANHOLE HIGHER THAN, THE LOWEST DRAIN AND BLOCKAGE.IN SEWER MAIN BACKWATER CONDITION INTO BUILDING WITHOUT BACKWATER VALVE UF5TREAM MANHOLE 5TPEE, -i- BACKWATER. 5:wrP 5E1VIC I MIMI ���BAG K VVA�CONDITION PREVENTED BY BLOCKAGE' 3A rVVATERVALVE NOTE: WHEN WATERTIGHT NOT SPECIFIED, TOP SHALL SHALL HAVE, ONE ],'I VENT HOLE. 27 1/2" 2G,114�' 24, 111 G' -------------------- 24 112" 7 112" 26 3/ I Gf' FRAME 5ECTIOR (2) SS'ROLL PINS (2) CAM LOCKS I 12",DIA x 1 3/4" 3 7/Y 51ic- 5/5" 20 1 5/45" —E — - 1 2 716' I WIPER CA5rETT 3/4" 5/811 5. TyjICALt CAM LOCK MANHOLE FINNED GASKET IN VERTICAL FACE OF"COVER TO MAKE WATERTIGHT. 11/4" COVER BOTTOM OF FKAME, YAKP/VAULTIN5TALLATION FOR HOUSE' BUILDINGS BUILT ON SLAB AND OC OTHER LOCATIONS "ERE VALVE CANNOT BE INSTALLED IN BASEMENT OR CRAWL SPACE. C1350 4 METER BOX LOR : SIMILAR BOX/VAU LT 1 OF APPROPRIATE SIZE TO ALLOW REGU LAP, MAINTENANCE NOTES - 1. INSTALLATIONS OF GREATER THAN 4' IN DEPTH MAY KE -QUIRE MANHOLE. 2, VALVES MUST BE INSTALLED INA LOCATION AT WHICH THEY CAN BE CLEANED AND SERVICED REGULARLY. 4- 1 " DIA HOLE5 @ I MINIMUM AIG 4VEIG11T FRAME 152 COVER I GO TOTAL 342 (2) LIFTING 13AR5 0 0 I "w 0 0 III LETTERING RECESSED FLUSH PLAN 25 1/41' 2G 1/4" 17! --T 7 112" GASKET IN I VERTICAL 22" PAGE F COVER KING MUST BE - 28" ANCHORED IN — 34" ACCORDANCE MTH S-25 5/6" o/ —STAINLESS STEEL ROD TYPICAL LIFTING DEVICE SECTION A CITY OF RALEIGH DEPARTMENT _OF PUBLIC UTILITIES MANHOLE FRAME AND WATERTIGHT COVER DWG. NO. >REVISIONS -DATE REVISIONS DATE 5-2G 3-1-67 18-1-57 ADD 5-29-051 P\kH 13-30-001 D, H. L. 61 1810"8 1 BUILDING WITH NEXT UPSTREAM MANHOLE HIGHER THAN, THE LOWEST DRAIN AND BLOCKAGE.IN SEWER MAIN BACKWATER CONDITION INTO BUILDING WITHOUT BACKWATER VALVE UF5TREAM MANHOLE 5TPEE, -i- BACKWATER. 5:wrP 5E1VIC I MIMI ���BAG K VVA�CONDITION PREVENTED BY BLOCKAGE' 3A rVVATERVALVE NOTE: WHEN WATERTIGHT NOT SPECIFIED, TOP SHALL SHALL HAVE, ONE ],'I VENT HOLE. 27 1/2" 2G,114�' 24, 111 G' -------------------- 24 112" 7 112" 26 3/ I Gf' FRAME 5ECTIOR (2) SS'ROLL PINS (2) CAM LOCKS I 12",DIA x 1 3/4" 3 7/Y 51ic- 5/5" 20 1 5/45" —E — - 1 2 716' I WIPER CA5rETT 3/4" 5/811 5. TyjICALt CAM LOCK MANHOLE FINNED GASKET IN VERTICAL FACE OF"COVER TO MAKE WATERTIGHT. 11/4" COVER BOTTOM OF FKAME, OPEN OC POSITION BOTTOM OF COVER CLOSED VLOCKING DEVICE POSITION (4� FRAME STANDARD - PENTAGON HEAD S.S. BOTTOM OPTIONAL HEX HEAD BOLT OF FRAME TYPICAL LOCKING DEVICE CITY Of RALEIGH DEPARTMENT'Of PUBLIC UTILITIES RING MUST BE ANCHORED WATER -TIGHT MANHOLE FRAME IN ACCORDANCE WITH 5-25 WITH CAM LOCK COVER DWG, NO. REVISIONS DATE REVISIONS DATE 5-27 1 RRH 13-30-00 1 DH L C-18-0€5; FINAL DRAWING RELEASED FOR CONSTRUCTION co o 0 C" ci cri vgz 00 00 :%,z 1,3 r.) to- I M IIIc" 00, CA 4 80 Z /V G. z 0 � W � C) MWM E--4 0 14 co pq Cf VJ Z cq z 0 Z AdMIN& P4 z 0 u PROJECT NO- JPM-15010 FILENAME: JPM15010— 1 DESIGNED BY: NIDW DRAWN BY: DLP SCALE: N.T.S. DATE: 04-04-2016 SHEET NO. D-9 1111MC ADAMS ADAms II TEMPORARY DIVERSION DITCH DESIGN TABLE A, TEMPORARY TEMPORARY DIVERSION ID TD-1 TD -2 TD -3 MINIMUM DEPTH FT 1.01 1.59 1.01 CALCULATED VELOCITY 2.48 3.73 2.57 ALLOWABLE VELOCITY 6.00 6.00 6.00 CALCULATED SHEAR STRESS 0.95 0.99 1.26 ALLOWABLE SHEAR STRESS 1.75 1.75 1.75 TEMPORARY LINER SPECIFICATION* ERONET DS150 ERONET DS150 ERONET DS150 \ \ S`' ~\� \ w$ 9 �o \ * ALL SPECIFICATIONS ARE NORTH AMERICAN GREEN ROLLMAX PRODUCTS OR EQUAL.. / �� / (STING ;CURB D s Hl� / UTTER 0 BE v�v �v �� D sD_z REMO(SEE( �� �\� '''�-sow_ -------------------------- EP C-2)/ �A\ so --- SHE-� !. \� ti SD _ _ i-- SD SD SD SD SD SD tt SD SD SD Ili T/ f ^ r TYPE/111 / LIMITS OF BARRICADE/ DISTURBANCE�A� �� A _ T - I / 1 V Iry LIMITS OF /,/� ,�� � � ��D / DISTURBANE55 �[ J I / \\ \\ "('" �< <o =---_---�_---\ -----\ -- -- 1 .� / \ .,..,.,,� --� c- - 50 / �,� / �� ( �� !� v\ v�VA -- _ ---asp ___---� ��TEMpORARY I% T - sem- -(--1� CLEAN WATER C v - - - - - - - � *I / \\ VA\ - ago-� DIVERSION DITCH (TY!,?,, -- y sF CiNSTRUCTIONNA� / v BEGINNING OF TEMPORARY ENT1;tANCE / f V A� \� ^ \ \ DIVERSION DITCH TD -1. \ V v� �v a.vv, A MIN 10' OF SEPARATION FROM ADJACENT CLEANA \� STOG�KPILE v / v WATER DIVERSION DITCH/ V / / �� / / A A \ \ \ v I \ \\ / // / / / \ \ / / / `'/ SILT F NCE �QUTLi I �� \\�� \\ / \ \ , A ALL LbW SOTS /(TT11, ` I ► , I t i v v v SILT FENCE OUTLET IN / \ \ v BALL LOW SPOTS (TYP.)/ js ICHECI�,J�AM \\ ` ✓ / I I I I J v, l�� .. \-- ECK DAM SILT FENCE (NP.) CQNSTRUCTION SEQUENCE - STAGE 1: 1 1 ) 1 TOWN OF WAKE FOREST EROSION CONTROL NOTES), THE CONTRACTOR CAN 1 INSTALL INITIAL EROSION CONTROL MEASURES ONLY. THIS INCLUDES BUT IS Disturbed Area (AC.) NOT LIMITED TO CONSTRUCTION ENTRANCE, SILT FENCE, PERIMETER 9.68 DIVERSION DITCHES, CHECK DAMS (ROCK OR WADDLE TYPE), TREE 9.75 PROTECTION FENCE, EXISTING INLET PROTECTION, SEDIMENT BASINS, AND Bottom Elevation (FT) SKIMMER BASINS. CLEAR ONLY AS NECESSARY TO INSTALL THESE \� MEASURES. V .1 \ 2. CONTRACTOR IS RESPONSIBLE FOR E&SC WEEKLY INSTALLATION AND A 2.00 V / COVER. A RAIN GAGE, COPY OF TOWN SIGNED PLANS, REVISED SIGNED 1 PLANS, NPDES LOG, AND CONSTRUCTION BOX MUST BE PRESENT AND j EASILY ACCESSIBLE ONSITE. 3.OH:1 V 3.OH:1 V \ \ S`' ~\� \ w$ 9 �o \ * ALL SPECIFICATIONS ARE NORTH AMERICAN GREEN ROLLMAX PRODUCTS OR EQUAL.. / �� / (STING ;CURB D s Hl� / UTTER 0 BE v�v �v �� D sD_z REMO(SEE( �� �\� '''�-sow_ -------------------------- EP C-2)/ �A\ so --- SHE-� !. \� ti SD _ _ i-- SD SD SD SD SD SD tt SD SD SD Ili T/ f ^ r TYPE/111 / LIMITS OF BARRICADE/ DISTURBANCE�A� �� A _ T - I / 1 V Iry LIMITS OF /,/� ,�� � � ��D / DISTURBANE55 �[ J I / \\ \\ "('" �< <o =---_---�_---\ -----\ -- -- 1 .� / \ .,..,.,,� --� c- - 50 / �,� / �� ( �� !� v\ v�VA -- _ ---asp ___---� ��TEMpORARY I% T - sem- -(--1� CLEAN WATER C v - - - - - - - � *I / \\ VA\ - ago-� DIVERSION DITCH (TY!,?,, -- y sF CiNSTRUCTIONNA� / v BEGINNING OF TEMPORARY ENT1;tANCE / f V A� \� ^ \ \ DIVERSION DITCH TD -1. \ V v� �v a.vv, A MIN 10' OF SEPARATION FROM ADJACENT CLEANA \� STOG�KPILE v / v WATER DIVERSION DITCH/ V / / �� / / A A \ \ \ v I \ \\ / // / / / \ \ / / / `'/ SILT F NCE �QUTLi I �� \\�� \\ / \ \ , A ALL LbW SOTS /(TT11, ` I ► , I t i v v v SILT FENCE OUTLET IN / \ \ v BALL LOW SPOTS (TYP.)/ js ICHECI�,J�AM \\ ` ✓ / I I I I J v, l�� .. \-- ECK DAM SILT FENCE (NP.) /U 1 1 �L_ -1 1 IN" 1 1 . A \ A�-NI A ! / /"X _ 22\ \ \ Y\AV1� i ' snob QAmOc b,W_- ♦ /9 l/ SEDIMENT BASIN/SKIMMER BASIN DESIGN TABLE CQNSTRUCTION SEQUENCE - STAGE 1: 1 1. AFTER THE PRECONSTRUCITON MEETING IS HELD (SEE NOTE 6 BELOW, IN 1 TOWN OF WAKE FOREST EROSION CONTROL NOTES), THE CONTRACTOR CAN 1 INSTALL INITIAL EROSION CONTROL MEASURES ONLY. THIS INCLUDES BUT IS Disturbed Area (AC.) NOT LIMITED TO CONSTRUCTION ENTRANCE, SILT FENCE, PERIMETER 9.68 DIVERSION DITCHES, CHECK DAMS (ROCK OR WADDLE TYPE), TREE 9.75 PROTECTION FENCE, EXISTING INLET PROTECTION, SEDIMENT BASINS, AND Bottom Elevation (FT) SKIMMER BASINS. CLEAR ONLY AS NECESSARY TO INSTALL THESE \� MEASURES. 2.00 2.00 \ 2. CONTRACTOR IS RESPONSIBLE FOR E&SC WEEKLY INSTALLATION AND A 2.00 MAINTENANCE LOG INCLUDING DATES OF TEMPORARY/PERMANENT GROUND / COVER. A RAIN GAGE, COPY OF TOWN SIGNED PLANS, REVISED SIGNED 1 PLANS, NPDES LOG, AND CONSTRUCTION BOX MUST BE PRESENT AND j EASILY ACCESSIBLE ONSITE. 3.OH:1 V 3.OH:1 V Spillway Length (FT) 3. ONCE MEASURES ARE INSTALLED, CONTRACTOR/FINANCIALLY RESPONSIBLE 30.0 OWNER (FRO) TO CALL TOWN FOR AN INITIAL INSPECTION. IF SITE PASSES 4.00 INSPECTION, A CERTIFICATE OF COMPLIANCE WILL BE ISSUED. CONTRACTOR CAN NOW BEGIN CLEARING, GRUBBING, AND GRADING WITHIN THE LIMITS Top of Trap Length (FT) 124 184 SHOWN. 54 98 Storage Volume Required (FT') 4. THE PROJECT HAS BEEN PHASED TO LEAVE AS LITTLE CONTIGUOUS GROUND 17424 OPEN AS POSSIBLE. 7,640 26,460 Sediment Surface Area Req'd (FTS) 5. TEMPORARILY SEED, STRAW AND TACK OR HYDROSEED WITHIN 14 DAYS OF 12,580 ANY PHASE OF GRADING, INCLUDING SLOPES. SEED BASINS AND DITCHES 4,700 IMMEDIATELY AFTER CONSTRUCTION. Number of Skimmers 6. PRIOR TO REMOVAL OF TEMPORARY MEASURES OR REDUCTION OF SKIMMER so BASINS, TOWN MUST APPROVE REMOVAL. ALL AREAS ABOVE TEMPORARY 2.00 MEASURE MUST HAVE 85% GROUND COVER. Skimmer Orifice Size (IN) 1.50 \\ 7. THE TOWN OF WAKE FOREST EROSION CONTROL INSPECTOR WILL EVALUATE \� THE SITE AT LEAST ONCE A MONTH. A COPY OF THE INSPECTION FORM \ WILL BE EMAILED TO THE FRO. THE WEEKLY EROSION LOG AND NPDES LOG N/A MUST BE ONSITE AND AVAILABLE FOR REVIEW. 71 �� \ N/A Notes: 8. IF THE SITE IS FOUND OUT OF COMPLIANCE A NOTICE OF VIOLATION WILL 1. See details on silt fence baffle spacing. BE ISSUED GIVING THE CONTRACTOR/FRO 7 WORKING DAYS TO REMEDY THE "- PROBLEM. IF THE SITUATION IS NOT RESOLVED WITHIN THE TIME PERIOD A �. FINE MAY BE ISSUED. t ` 9. IF SEDIMENT LEAVES THE SITE A FINE MAY BE ISSUED UP TO $5,000 PER DAY PER VIOLATION. IF SEDIMENT ENTERS A BUFFER, STREAM, OR WETLAND NCDWQ WILL BE NOTIFIED. THEY MAY ISSUE FINES UP TO $25,000 PER DAY PER VIOLATION. \ 10. MOVE TO STAGE 2 EROSION CONTROL PLAN. TOWN OF WAKE FOREST EROSION CONTROL NOTES: 1. A LAND DISTURBING (E&SC) PERMIT IS REQUIRED FOR PROJECTS OVER t l 0.50 ACRE. IF MULTIPLE LOTS WITH LAND DISTURBANCE OVER 0.50 ACRE TOTAL ARE EITHER CONTIGUOUS OR NON-CONTIGUOUS IN THE SAME SUBDIVISION, BEING TAKEN DOWN BY THE SAME BUILDER/OWNER, A LAND DISTURBING PERMIT IS REQUIRED. THE COST OF THE PLAN REVIEW AND i PERMIT IS $400/ACRE ROUNDED UP (1.1 ACRES = 2 ACRES $400/ACRE = $800). THE FEE IS DUE AT TIME OF PLAN SUBMITTAL. / DEVELOPER IS RESPONSIBLE FOR INFORMING BUILDER OF E&SC PERMIT ! t REQUIREMENTS ON INDIVIDUAL LOTS. DISCLAIMER: TOWN OF WAKE FOREST r�Jr^: FEES AND CHARGES ARE SUBJECT TO CHANGE WITHOUT NOTICE. PLEASE / CALL 919-435-9443 TO CONFIRM CURRENT FEES AND CHARGES. 2. IF ADDITIONAL ACREAGE IS ADDED TO AN EXISTING PERMIT, REVISED FORMS, PLANS, AND ANY ADDITIONAL FEESMUST BE SUBMITTED. 3. IF OWNERSHIP OF A PROPERTY HAS CHANGED A REVISED FINANCIAL RESPONSIBILITY/OWNERSHIP (F.R.O.) FORM MUST BE SUBMITTED. 4. IF A PROPERTY IS TAKEN OVER BY THE BANK, THE BANK SHALL CONTACT THE TOWN EROSION AND REPAIR ALL CONTROL MEASURES TO 1 / TOWN/NCDENR STANDARDS. THEY SHALL ALSO SUBMIT A NEW F.R.O. FORM. 5. IF A PROJECT IS NOT COMPLETE WITHIN TWO YEARS, THE PLANS MUST BE RENEWED AT $250/ACRE. A REVISED SET OF PLANS MAY BE SUBMITTED IF i ACREAGE HAS ALREADY BEEN DEVELOPED AND A CERTIFICATE OF OCCUPANCY HAS BEEN ISSUED. J t 6. AN EROSION PRECONSTRUCTION MEETING MUST BE HELD WITH THE TOWN OF WAKE FOREST PRIOR TO START OF ANY WORK, INCLUDING INSTALLATION OF EROSION CONTROL MEASURES, DEMOLITION, CUTTING TREES, AND GRUBBING. CALL ENGINEERING AT (919) 435-9443 TO SET UP A MEETING. ALL PLANS MUST BE SIGNED AND COPIES RETURNED BACK TO THE TOWN 1 WEEK PRIOR TO PRECONSTRUCTION MEETING. 7. THE OWNER, GENERAL CONTRACTOR, GRADING COMPANY, AND EROSION `.: CONTROL INSTALLER MUST BE PRESENT AT THE PRECONSTRUCITON MEETING. .-^.-...�^� . 8. THE E&SC PERMIT AND NPDES GENERAL STORMWATER PERMIT WILL BE �^- GIVEN OUT AT THIS MEETING 9. ALL SILT FENCE MUST BE TRENCHED AT A MINIMUM DEPTH OF 6 INCHES. EROSION CONTROL LEGEND /U 1 1 �L_ -1 1 IN" 1 1 . A \ A�-NI A ! / /"X _ 22\ \ \ Y\AV1� i ' snob QAmOc b,W_- ♦ /9 l/ SEDIMENT BASIN/SKIMMER BASIN DESIGN TABLE As SEDIMENT TRAP ID ST -1 SEDIMENT TRAP ST -2 SEDIMENT TRAP Drainage Area (AC.) 2.25 9.68 Disturbed Area (AC.) 2.25 9.68 Flow Q10 (CFS) 9.75 38.34 Bottom Elevation (FT) 342.0 322.0 Sediment Depth (FT) 2.00 2.00 Freeboard (from Sediment Depth) 2.00 2.00 Depth to Crest of Riser (FT) 2.00 2.00 Depth to Crest of Emergency Spillway (FT) 2.50 2.50 Side Slopes 3.OH:1 V 3.OH:1 V Spillway Length (FT) 2010 30.0 Height of Berm (FT) 4.00 4.00 Top of Trap Length (FT) 124 184 Top of Trap Width (FT) 54 98 Storage Volume Required (FT') 4,050 17424 Storage Volume ProVd. (FTS 7,640 26,460 Sediment Surface Area Req'd (FTS) 3,060 12,580 Sediment Surface Area ProVd (FT°) 4,700 14,730 Number of Skimmers 1 1 Skimmer Size (IN) 2.00 2.50 Skimmer Orifice Size (IN) 1.50 2.50 Anti -Flotation Block N/A N/A Riser Diameter (IN) N/A N/A Barrel Diameter (IN) N/A N/A Notes: 1. See details on silt fence baffle spacing. AINTENANCE PLAN: 1. ALL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE CHECKED BY THE CONTRACTOR FOR STABILITY AND OPERATION FOLLOWING EVERY RUNOFF -PRODUCING RAINFALL BUT IN NO CASE LESS THAN ONCE EVERY WEEK. ANY NEEDED REPAIRS SHALL BE MADE IMMEDIATELY TO MAINTAIN ALL MEASURES AS DESIGNED. 2. SEDIMENT BASINS SHALL BE INSPECTED REGULARLY DURING LAND DISTURBING ACTIVITIES AND AFTER EACH RUNOFF -PRODUCING RAINFALL. SEDIMENT SHALL BE REMOVED AND THE BASIN RESTORED TO ITS ORIGINAL DIMENSIONS WHEN SEDIMENT HAS ACCUMULATED TO ONE-HALF THE DESIGN DEPTH OF EACH BASIN. 3. SEDIMENT FENCES SHALL BE INSPECTED AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. REPAIRS SHALL BE MADE IMMEDIATELY. SEDIMENT DEPOSITS SHALL BE REMOVED AS NEEDED TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAINFALL EVENT, AND TO REDUCE PRESSURE ON THE FENCE. FENCING MATERIALS AND SEDIMENT DEPOSITS SHALL BE REMOVED, AND THE AREA BROUGHT TO GRADE FOLLOWING STABILIZATION OF UPGRADIENT DISTURBED AREAS. 4. DIVERSION DITCHES MUST REMAIN IN PLACE UNTIL PROJECT IS STABILIZED. 5. MUD AND DEBRIS MUST BE KEPT OFF OF EXISTING PORTIONS OF ANY EXISTING PAVED ROAD AND/OR PRIVATE DRIVEWAY AT ALL TIMES. IF MUD AND DEBRIS IS TRACKED FROM THE SITE, IT MUST BE REMOVED IMMEDIATELY. FAILURE TO FOLLOW THIS PROCEDURE MAY RESULT IN PUNITIVE ACTION BEING TAKEN, INCLUDING A STOP WORK ORDER, FINES AND/OR REVOKING THE GRADING PERMIT. 6. GRADED SLOPES AND FILLS ARE TO BE PLANTED OR PROVIDED WITH PROTECTIVE COVER SUFFICIENT TO RESTRAIN EROSION AFTER THE COMPLETION OF ANY PHASE OF GRADING. ALL AREAS UPON WHICH NO FURTHER LAND DISTURBING ACTIVITY WILL BE UNDERTAKEN ARE TO BE PLANTED OR PROVIDED WITH PROTECTIVE COVER WITHIN THE TIME FRAMES SHOWN IN THE GROUND STABILIZATION TABLE. SILT FENCE OUTLET CHECK DAM -SF SF SF - SILT FENCE SITE AREA STABILIZATION STABILIZATION TIME DESCRIPTION TIME FRAME FRAME EXCEPTIONS -T' TP TP - TREE PROTECTION FENCE PERIMETER DIKES, LD LD LIMITS OF DISTURBANCE SWALES, DITCHES 7 DAYS NONE AND SLOPES HIGH QUALITY WATER 7 DAYS NONE WOODED AREA (HQW) ZONES �i�►�i/�►� DIVERSION DITCH IF SLOPES ARE 10' SLOPES STEEPER OR LESS IN LENGTH °p0 yc� 7 DAYS AND ARE NOT STEEPER THAN 3:1 ( o i° / / THAN 2:1, 14 DAYS o °� o CONSTRUCTION ENTRANCE EXIT ARE ALLOWED / t ,p �. \ \ 7 -DAYS FOR SLOPES V SKIMMER % \ SLOPES 3:1 OR ( A \ \ ASSEMBLY / % % / 14 DAYS GREATER THAN 50 O-° \ , "� FLATTER FEET IN LENGTH ;,. 1 ALL OTHER AREAS NONE (EXCEPT FOR (t ( A \V° WITH SLOPES 14 DAYS PERIMETERS AND HOW ! F I 1 \ FLATTER THAN 4:1 ZONES) THESE PLANS HAVE BEEN APPROVED FOR CONSTRUCTION BY THE TOWN OF WAKE FOREST -0,5 Al En ee n De artment _ ate 71L� Public Works Department Date Er o & Sediment Control Date Vluau City of Raleigh Public Utilitiesl Department ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH TOWN OF WAKE FOREST, CITY OF RALEIGH & NCDOT (WHERE APPLICABLE) STANDARDS, SPECIFICATIONS, AND DETAILS. HORIZONTAL DATUM: NAD83 VERTICAL DATUM: NGVD29 Date As Date y Date Date Date GRAPHIC SCALE 60 0 30 60 120 1 inch = 60 ft. FINAL DRAWING - RELEASED FOR CONSTRUCTION M p • �N U M I (Cal d UZ V5 074 Z 48 M M h N O_ o Q�0 VJ �N CA 0 80 %���,9T INE, .•o ,��� N tj„il il, � O W atx ►� Q a� Z O W O C\2 W E4 Z E' a � ©w ::� c V r -i VJ C} Cq a wO o OZ w 0 Z U w PROJECT N0. JPM-15010 FILENAME: JPM15010-EC1 DESIGNED BY: N D W DRAWN BY: DLP SCALE: 1„ = 60' DATE: 04-04-2016 SHEET N0. C-1 !!11 MCADAMS D�n k (TYP TYPE III - BARRICADE L1 i,11J 111 \ l., TRADITIONS RIDGE DRIVE 60' PUBLIC R/W SEDIMENT BASIN/SKIMMER BASIN DESIGN TABLE SITE AREA SEDIMENT TRAP ID ST -1 SEDIMENT TRAP ST -2 SEDIMENT TRAP Drainage Area (AC.) 3.02 6.95 Disturbed Area (AC.) 3.02 6.95 Flow Q10 (CFS) 12.66 18.61 Bottom Elevation (FT) 342.0 322.0 Sediment Depth (FT) 2.00 2.00 Freeboard (from Sediment Depth) 2.00 2.00 Depth to Crest of Riser (FT) 2.00 2.00 Depth to Crest of Emergency Spillway (FT) 2.50 2.50 Side Slopes 3.OH:1 V 3.OH:1 V Spillway Length (FT) 10.0 10.0 Height of Berm (FT) 4.00 4.00 Top of Trap Length (FT) 124 160 Top of Trap Width (FT) 54 74 Storage Volume Required (FT') 5,436 12510 Storage Volume Prov d. (FT') 7,640 24,460 Sediment Surface Area Req'd (FTs) 4,250 9,790 Sediment Surface Area ProVd (FT2) 4,700 14,730 Number of Skimmers 1 1 Skimmer Size (IN) 2.00 2.50 Skimmer Orifice Size (IN) 1.50 2.50 Anti -Flotation Block N/A N/A Riser Diameter (IN) N/A N/A Barrel Diameter (IN) N/A N/A Notes: 1. See details on silt fence baffle spacing. EXISTING CITY OF RALEIGH 301• SANITARY SEWER EASEMENT T T.11111�' 1 ' 1. ALL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE CHECKED BY THE CONTRACTOR FOR STABILITY AND OPERATION FOLLOWING EVERY RUNOFF -PRODUCING RAINFALL BUT IN NO CASE LESS THAN ONCE EVERY WEEK. ANY NEEDED REPAIRS SHALL BE MADE IMMEDIATELY TO MAINTAIN ALL MEASURES AS DESIGNED. 2. SEDIMENT BASINS SHALL BE INSPECTED REGULARLY DURING LAND DISTURBING ACTIVITIES AND AFTER EACH RUNOFF -PRODUCING RAINFALL. SEDIMENT SHALL BE REMOVED AND THE BASIN RESTORED TO ITS ORIGINAL DIMENSIONS WHEN SEDIMENT HAS ACCUMULATED TO ONE-HALF THE DESIGN DEPTH OF EACH BASIN. 3. SEDIMENT FENCES SHALL BE INSPECTED AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. REPAIRS SHALL BE MADE IMMEDIATELY. SEDIMENT DEPOSITS SHALL BE REMOVED AS NEEDED TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAINFALL EVENT, AND TO REDUCE PRESSURE ON THE FENCE. FENCING MATERIALS AND SEDIMENT DEPOSITS SHALL BE REMOVED, AND THE AREA BROUGHT TO GRADE FOLLOWING STABILIZATION OF UPGRADIENT DISTURBED AREAS. 4. DIVERSION DITCHES MUST REMAIN IN PLACE UNTIL PROJECT IS STABILIZED, 5. MUD AND DEBRIS MUST BE KEPT OFF OF EXISTING PORTIONS OF ANY EXISTING PAVED ROAD AND/OR PRIVATE DRIVEWAY AT ALL TIMES. IF MUD AND DEBRIS IS TRACKED FROM THE SITE, IT MUST BE REMOVED IMMEDIATELY. FAILURE TO FOLLOW THIS PROCEDURE MAY RESULT IN PUNITIVE ACTION BEING TAKEN, INCLUDING A STOP WORK ORDER, FINES AND/OR REVOKING THE GRADING PERMIT. 6. GRADED SLOPES AND FILLS ARE TO BE PLANTED OR PROVIDED WITH PROTECTIVE COVER SUFFICIENT TO RESTRAIN EROSION AFTER THE COMPLETION OF ANY PHASE OF GRADING. ALL AREAS UPON WHICH NO FURTHER LAND DISTURBING ACTIVITY WILL BE UNDERTAKEN ARE TO BE PLANTED OR PROVIDED WITH PROTECTIVE COVER WITHIN THE TIME FRAMES SHOWN IN THE GROUND STABILIZATION TABLE. 7 1. THE CONTRACTOR SHALL INSTALL STORM DRAINAGE WITH INLET PROTECTION. 2. THE PROJECT HAS BEEN PHASED TO LEAVE AS LITTLE CONTIGUOUS GROUND OPEN AS POSSIBLE. 3. ADJUST BAFFLES FOR ST -1 AS SHOWN. 4. CONTRACTOR IS TO INSTALL TEMPORARY OUTLET PIPES FOR SD 100 AND SD 200 STORM DRAINAGE SYSTEMS AS INDICATED ON THE PLAN. THEIR STARTING INVERTS SHALL MATCH THE INVERTS OF THE PERMANENT PIPES SHOWN ON SHEET C-7. THESE TEMPORARY PIPES ARE TO REMAIN IN PLACE UNTIL THE END OF THE EROSION CONTROL SEQUENCE. ONCE STORM DRAINAGE AND INLET PROTECTION ARE IN PLACE, ROADS AND LOTS SHALL BE BUILT UP TO GRADE. ST -1 & ST -2 SHALL CONTINUE TO FUNCTION AS SEDIMENT BASINS UNTIL LEVEL SPREADERS ARE INSTALLED. 5. TEMPORARILY SEED, STRAW AND TACK OR HYDROSEED WITHIN 14 DAYS OF ANY PHASE OF GRADING, INCLUDING SLOPES. SEED BASINS AND DITCHES IMMEDIATELY AFTER CONSTRUCTION. SEED "BORROW" SITES WITHIN 14 DAYS OF INACTIVITY. 6. PRIOR TO REMOVAL OF TEMPORARY MEASURES, TOWN MUST APPROVE REMOVAL. ALL AREAS ABOVE TEMPORARY MEASURE MUST HAVE 85% GROUND COVER. 7. THE TOWN OF WAKE FOREST EROSION CONTROL INSPECTOR WILL EVALUATE THE SITE AT LEAST ONCE A MONTH. A COPY OF THE INSPECTION FORM WILL BE EMAILED TO THE FRO. THE WEEKLY EROSION LOG AND NPDES LOG MUST BE ONSITE AND AVAILABLE FOR REVIEW. 8. IF THE SITE IS FOUND OUT OF COMPLIANCE A NOTICE OF VIOLATION WILL BE ISSUED GIVING THE CONTRACTOR/FRO 7 WORKING DAYS TO REMEDY THE PROBLEM. IF THE SITUATION IS NOT RESOLVED WITHIN THE TIME PERIOD A FINE MAY BE ISSUED. 9. IF SEDIMENT LEAVES THE SITE A FINE MAY BE ISSUED UP TO $5,000 PER DAY PER VIOLATION. IF SEDIMENT ENTERS A BUFFER, STREAM, OR WETLAND NCDWQ WILL BE NOTIFIED. THEY MAY ISSUE FINES UP TO $25,000 PER DAY PER VIOLATION. 10. CALL THE TOWN UPON COMPLETION FOR A FINAL EROSION INSPECTION. A PUNCHLIST MAY BE GENERATED ADDRESSING ANY REMAINING ITEMS. THERE MUST BE 85% GROUNDCOVER ON THE ENTIRE SITE PRIOR TO A CERTIFICATE OF OCCUPANCY. IF THE SITE IS FOUND TO BE IN COMPLIANCE AN EROSION CERTIFICATE OF COMPLETION WILL BE ISSUED. 11. CONTRACTOR SHALL REMOVE ALL EROSION CONTROL MEASURES, AS PERMITTED BY EROSION CONTROL INSPECTIONS DEPARTMENT. CONTRACTOR SHALL REPLACE TEMPORARY PIPE (REFER TO NOTE #3) WITH PERMANENT STORM DRAINAGE PIPES AND STRUCTURES AS SHOWN ON SHEET C-7. TOWN OF WAKE FOREST EROSION CONTROL NOTES: 1. A LAND DISTURBING (E&SC) PERMIT IS REQUIRED FOR PROJECTS OVER 0.50 ACRE. IF MULTIPLE LOTS WITH LAND DISTURBANCE OVER 0.50 ACRE TOTAL ARE EITHER CONTIGUOUS OR NON-CONTIGUOUS IN THE SAME SUBDIVISION, BEING TAKEN DOWN BY THE SAME BUILDER/OWNER, A LAND DISTURBING PERMIT IS REQUIRED. THE COST OF THE PLAN REVIEW AND PERMIT IS $400/ACRE ROUNDED UP (1.1 ACRES = 2 ACRES $400/ACRE = $800). THE FEE IS DUE AT TIME OF PLAN SUBMITTAL. DEVELOPER IS RESPONSIBLE FOR INFORMING BUILDER OF E&SC PERMIT REQUIREMENTS ON INDIVIDUAL LOTS. DISCLAIMER: TOWN OF WAKE FOREST FEES AND CHARGES ARE SUBJECT TO CHANGE WITHOUT NOTICE. PLEASE CALL 919-435-9443 TO CONFIRM CURRENT FEES AND CHARGES. 2. IF ADDITIONAL ACREAGE IS ADDED TO AN EXISTING PERMIT, REVISED FORMS, PLANS, AND ANY ADDITIONAL FEES MUST BE SUBMITTED. 3. IF OWNERSHIP OF A PROPERTY HAS CHANGED A REVISED FINANCIAL RESPONSIBILITY/OWNERSHIP (F.R.O.) FORM MUST BE SUBMITTED. 4. IF A PROPERTY IS TAKEN OVER BY THE BANK, THE BANK SHALL CONTACT THE TOWN AND REPAIR ALL EROSION CONTROL MEASURES TO TOWN/NCDENR STANDARDS. THEY SHALL ALSO SUBMIT A NEW F.R.O. FORM. 5. IF A PROJECT IS NOT COMPLETE WITHIN TWO YEARS, THE PLANS MUST BE RENEWED AT $250/ACRE. A REVISED SET OF PLANS MAY BE SUBMITTED IF ACREAGE HAS ALREADY BEEN DEVELOPED AND A CERTIFICATE OF OCCUPANCY HAS BEEN ISSUED. 6. AN EROSION PRECONSTRUCTION MEETING MUST BE HELD WITH THE TOWN OF WAKE FOREST PRIOR TO START OF ANY WORK, INCLUDING INSTALLATION OF EROSION CONTROL MEASURES, DEMOLITION, CUTTING TREES, AND GRUBBING. CALL ENGINEERING AT (919) 435-9443 TO SET UP A MEETING. ALL PLANS MUST BE SIGNED AND COPIES RETURNED BACK TO THE TOWN 1 WEEK PRIOR TO PRECONSTRUCTION MEETING. 7. THE OWNER, GENERAL CONTRACTOR, GRADING COMPANY, AND EROSION CONTROL INSTALLER MUST BE PRESENT AT THE PRECONSTRUCITQN MEETING. 8. THE E&SC PERMIT AND NPDES GENERAL STORMWATER PERMIT WILL BE GIVEN OUT AT THIS MEETING 9. ALL SILT FENCE MUST BE TRENCHED AT A MINIMUM DEPTH OF 6 INCHES. EROSION CONTROL LEGEND TOTAL DISTURBED AREA- 15.81 AC. GROUND STABILIZATION SITE AREA STABILIZATION STABILIZATION TIME DESCRIPTION TIME FRAME FRAME EXCEPTIONS \ SWALES, DITCHES 7 DAYS 1. THE CONTRACTOR SHALL INSTALL STORM DRAINAGE WITH INLET PROTECTION. 2. THE PROJECT HAS BEEN PHASED TO LEAVE AS LITTLE CONTIGUOUS GROUND OPEN AS POSSIBLE. 3. ADJUST BAFFLES FOR ST -1 AS SHOWN. 4. CONTRACTOR IS TO INSTALL TEMPORARY OUTLET PIPES FOR SD 100 AND SD 200 STORM DRAINAGE SYSTEMS AS INDICATED ON THE PLAN. THEIR STARTING INVERTS SHALL MATCH THE INVERTS OF THE PERMANENT PIPES SHOWN ON SHEET C-7. THESE TEMPORARY PIPES ARE TO REMAIN IN PLACE UNTIL THE END OF THE EROSION CONTROL SEQUENCE. ONCE STORM DRAINAGE AND INLET PROTECTION ARE IN PLACE, ROADS AND LOTS SHALL BE BUILT UP TO GRADE. ST -1 & ST -2 SHALL CONTINUE TO FUNCTION AS SEDIMENT BASINS UNTIL LEVEL SPREADERS ARE INSTALLED. 5. TEMPORARILY SEED, STRAW AND TACK OR HYDROSEED WITHIN 14 DAYS OF ANY PHASE OF GRADING, INCLUDING SLOPES. SEED BASINS AND DITCHES IMMEDIATELY AFTER CONSTRUCTION. SEED "BORROW" SITES WITHIN 14 DAYS OF INACTIVITY. 6. PRIOR TO REMOVAL OF TEMPORARY MEASURES, TOWN MUST APPROVE REMOVAL. ALL AREAS ABOVE TEMPORARY MEASURE MUST HAVE 85% GROUND COVER. 7. THE TOWN OF WAKE FOREST EROSION CONTROL INSPECTOR WILL EVALUATE THE SITE AT LEAST ONCE A MONTH. A COPY OF THE INSPECTION FORM WILL BE EMAILED TO THE FRO. THE WEEKLY EROSION LOG AND NPDES LOG MUST BE ONSITE AND AVAILABLE FOR REVIEW. 8. IF THE SITE IS FOUND OUT OF COMPLIANCE A NOTICE OF VIOLATION WILL BE ISSUED GIVING THE CONTRACTOR/FRO 7 WORKING DAYS TO REMEDY THE PROBLEM. IF THE SITUATION IS NOT RESOLVED WITHIN THE TIME PERIOD A FINE MAY BE ISSUED. 9. IF SEDIMENT LEAVES THE SITE A FINE MAY BE ISSUED UP TO $5,000 PER DAY PER VIOLATION. IF SEDIMENT ENTERS A BUFFER, STREAM, OR WETLAND NCDWQ WILL BE NOTIFIED. THEY MAY ISSUE FINES UP TO $25,000 PER DAY PER VIOLATION. 10. CALL THE TOWN UPON COMPLETION FOR A FINAL EROSION INSPECTION. A PUNCHLIST MAY BE GENERATED ADDRESSING ANY REMAINING ITEMS. THERE MUST BE 85% GROUNDCOVER ON THE ENTIRE SITE PRIOR TO A CERTIFICATE OF OCCUPANCY. IF THE SITE IS FOUND TO BE IN COMPLIANCE AN EROSION CERTIFICATE OF COMPLETION WILL BE ISSUED. 11. CONTRACTOR SHALL REMOVE ALL EROSION CONTROL MEASURES, AS PERMITTED BY EROSION CONTROL INSPECTIONS DEPARTMENT. CONTRACTOR SHALL REPLACE TEMPORARY PIPE (REFER TO NOTE #3) WITH PERMANENT STORM DRAINAGE PIPES AND STRUCTURES AS SHOWN ON SHEET C-7. TOWN OF WAKE FOREST EROSION CONTROL NOTES: 1. A LAND DISTURBING (E&SC) PERMIT IS REQUIRED FOR PROJECTS OVER 0.50 ACRE. IF MULTIPLE LOTS WITH LAND DISTURBANCE OVER 0.50 ACRE TOTAL ARE EITHER CONTIGUOUS OR NON-CONTIGUOUS IN THE SAME SUBDIVISION, BEING TAKEN DOWN BY THE SAME BUILDER/OWNER, A LAND DISTURBING PERMIT IS REQUIRED. THE COST OF THE PLAN REVIEW AND PERMIT IS $400/ACRE ROUNDED UP (1.1 ACRES = 2 ACRES $400/ACRE = $800). THE FEE IS DUE AT TIME OF PLAN SUBMITTAL. DEVELOPER IS RESPONSIBLE FOR INFORMING BUILDER OF E&SC PERMIT REQUIREMENTS ON INDIVIDUAL LOTS. DISCLAIMER: TOWN OF WAKE FOREST FEES AND CHARGES ARE SUBJECT TO CHANGE WITHOUT NOTICE. PLEASE CALL 919-435-9443 TO CONFIRM CURRENT FEES AND CHARGES. 2. IF ADDITIONAL ACREAGE IS ADDED TO AN EXISTING PERMIT, REVISED FORMS, PLANS, AND ANY ADDITIONAL FEES MUST BE SUBMITTED. 3. IF OWNERSHIP OF A PROPERTY HAS CHANGED A REVISED FINANCIAL RESPONSIBILITY/OWNERSHIP (F.R.O.) FORM MUST BE SUBMITTED. 4. IF A PROPERTY IS TAKEN OVER BY THE BANK, THE BANK SHALL CONTACT THE TOWN AND REPAIR ALL EROSION CONTROL MEASURES TO TOWN/NCDENR STANDARDS. THEY SHALL ALSO SUBMIT A NEW F.R.O. FORM. 5. IF A PROJECT IS NOT COMPLETE WITHIN TWO YEARS, THE PLANS MUST BE RENEWED AT $250/ACRE. A REVISED SET OF PLANS MAY BE SUBMITTED IF ACREAGE HAS ALREADY BEEN DEVELOPED AND A CERTIFICATE OF OCCUPANCY HAS BEEN ISSUED. 6. AN EROSION PRECONSTRUCTION MEETING MUST BE HELD WITH THE TOWN OF WAKE FOREST PRIOR TO START OF ANY WORK, INCLUDING INSTALLATION OF EROSION CONTROL MEASURES, DEMOLITION, CUTTING TREES, AND GRUBBING. CALL ENGINEERING AT (919) 435-9443 TO SET UP A MEETING. ALL PLANS MUST BE SIGNED AND COPIES RETURNED BACK TO THE TOWN 1 WEEK PRIOR TO PRECONSTRUCTION MEETING. 7. THE OWNER, GENERAL CONTRACTOR, GRADING COMPANY, AND EROSION CONTROL INSTALLER MUST BE PRESENT AT THE PRECONSTRUCITQN MEETING. 8. THE E&SC PERMIT AND NPDES GENERAL STORMWATER PERMIT WILL BE GIVEN OUT AT THIS MEETING 9. ALL SILT FENCE MUST BE TRENCHED AT A MINIMUM DEPTH OF 6 INCHES. EROSION CONTROL LEGEND TOTAL DISTURBED AREA- 15.81 AC. GROUND STABILIZATION SITE AREA STABILIZATION STABILIZATION TIME DESCRIPTION TIME FRAME FRAME EXCEPTIONS PERIMETER DIKES, SWALES, DITCHES 7 DAYS NONE AND SLOPES HIGH QUALITY WATER (HQW) ZONES 7 DAYS NONE IF SLOPES ARE 10' SLOPES STEEPER OR LESS IN LENGTH THAN 3:1 7 DAYS AND ARE NOT STEEPER THAN 2:1, 14 DAYS ARE ALLOWED SLOPES 3:1 OR 7 -DAYS FOR SLOPES FLATTER 14 DAYS GREATER THAN 50 FEET IN LENGTH ALL OTHER AREAS NONE (EXCEPT FOR WITH SLOPES 14 DAYS PERIMETERS AND HQW FLATTER THAN 4:1 ZONES) •�ilHi(u� -SF SF SF - -TP TP TP - LD LD THESE PLANS HAVE BEEN APPROVED FOR CONSTRUCTION BY THE TOWN OF WAKE FOREST '3 Engineer' g De artment ate t(/�V/i� S ( f k Public Wqrks Department Date Er s o & Sediment Control Date SILT FENCE OUTLET INLET PROTECTION CHECK DAM SILT FENCE TREE PROTECTION LIMITS OF DISTURBANCE WOODED AREA CONSTRUCTION ENTRANCE/EXIT Fire Prev on Date xj W,4 Acces it Date ffnaing Dep ment Date b Urban Forestry Date City of Raleigh Pu lic Utilities Department Date GRAPHIC SCALE 60 0 30 60 120 1 inch = 60 ft. FINAL DRAWING - RELEASED FOR CONSTRUCTION CO p v r_4 tl �N U co Yt UZ 0:438 in -�� O P4 co N h CD A `, yiyiill itttl,I •�. L = 24680 �v�y �Gtkit:-x 4 N G - 'tltfiliiiiy ZO W tx Q aA a� .W E-4 W !(a Z oWoC\2 a`rrip-+44 U � E W Z 000-4 154 O 00 C\2 W ZZ 0 t 0 A � A QI 0 Z 0 a (p z o w "i W Z 0 0 tid w PROJECT No. JPM-15010 FH.SNAME: JPM15010-EC2 DESIGNED BY: N D W DRAWN BY: DLP SCALE: 1" = 60' DATE: 04-04-2016 SHEET N0. C-2 J MCADAMS 0 0) E 3: J X Table 6.10a Temporary Seeding Recommendations, for Late Winter and Early Spring Seeding mixture Species Rate(11 b/lacirel Cl Rye'(grain ) 4-29- use 110 Seeding dates Mountains --Above 2500 feet: 'Feb. 15 - May 1,5 Below 2500 feet: Feb. 1- M ay'l Piedmont -Jan. I - May 1 Coastal Plain -Dec, 1 -Apr 15 Soil amendments Follow recommendations of soil tests or apply 2,0010 lb/acre.grounricultural limestone d -7 and It 50 lb/acre 10-10-10 fertilizer. Mulch Apply 4,000 Iblacre straw. Anchor straw bytacking with asphalt, netting, or a mulch anchoring tool. A disk with blades set nearly straight can be used as a mulch anchoring tool Maintenance Refertjlizo, if growth is not full d at . �R ed, rtil ze , nd ul h y a equ e ese fefe� i a m immediately following erosion: or other damage. Table 6.10b Temporary Seeding Recommendations for Summer Seeding mixture Species Rate, (Ib/acre) German millet 40 In the Piedmont and Mountains, a small -stemmed Sudangrass may be substituted at a rate of 50 lb/acre. Seeding dates Mountains -May 15 - Aug� 15 edmont-May Coastal PlaAug. I - Soil amendments Follow recommendations of soil tests or apply 2,000 lb/acre ground agricultural limestone and 750 Ib/acre 10-10-10 fertilizer. Mulch Apply 4,000 Iblacre straw. Anchor straw,by tacking with asphalt, netting, or a mulch anchoring tool. Ndisk with blades set nearly straight can be used as a mulch anchoring tool. Maintenance Refertilize if growth is not fully adequate. Reseed, refertilize and mulch immediately following erosion or other damage. Table 6.1 Oc Temporary Seeding Recommendations for Fall Seeding mixture Species Rate (1b/acre) Rye (grain) 120 Seeding dates Mountains -Aug. 15 - Dec. 15 Coastal Plain and Piedmont -Aug. 15 - Dec. 30 Soil amendments Follow soil tests orapply 2,000 lb/acre ground agricultural limestone and 1,000 lb/acre 10-10-10 fertilizer. Mulch Apply 4,000 lb/acre straw. Anchor straw b y, tacking with asphalt, netting; or a mulch anchoringtool. A diskWith blades set nearly straight can be used as a mulch anchoring tool. Maintenance Repair and refertilize damaged areas immediately. TO dress with 50 lb/acre of nitrogen in March, If it is necessary to extent temporary cover beyond June 15, orseed with 50 lb/acre Kobe (Piedmont and Coastal Plain) or Korean (Mountains) lespedeza in late February or early March. TEMPORARY SEEDING PER NCDENR EROSION & SEDIMENT CONTROL PLANNING AND DESIGN MANUAL SECTION 6.10 HERBACEOUS PLANTS -Seeding recommendations for immediate stabilizationinurse Cr 0 to 6 weeks for devviopment-, effectWonalso 9*4:, 6 months to 9,y ear stabilization) NURSE CROP SPECIES - Table 6. 11.a _ Planting Dates Opfiinal Pfartino Dates get,- j sewing Few &MAoine cosw SuntShade Conrim Name Botanical Nam Lnt!aduced ftloom thimlecte mciurdans Pleomra piatu tollararit Walands mwan Buffers linveave installation Maintenance yes or JLo Considerations Other information, cominerdw Grain Socate cereals 1 40 The soil lost 1111 - 4i3a Bfl 5 4115 8115 - 4115 Sun Yes Yes No Must to mown b reduce Fertilizationt' linrestone Itislaore Mountans Ptcarrim co dueness with Sunt'Shade tolerant VIe.;avds Riparian Butfe;s or term 1 staliation 1 n Maintenance, considerationi; .0therinformation- corrMi2nary ras, Ivelletation N 'A, ev suit test 1211-4/15 NR wheat, TdOcum 1 30 itis By vA test 1111 4130 8M 6 - &I a ell 6 - 4ri 5 sun yea Yes No Must be mom to reduce Not water tolerant kilay be used No Pesreords "(ell 16 compettiverie3s with in wistiands that we not Cave-in-Rcck parmanerd or ImV term CQ llnlw saturated aontrrliedWMs �.4 X '4Bch vegetation onlv controlled burns, Mix with CWrommillet sawaiwim -4 101ba 18yaoiltast sun, yes yes; No'' 0(op should be cut I diso' Not water tolerant May be used 'hv, 5de'd V, - I .3 10 " (.it Irietles lixicir to plardiry primary or in wallands that we not �pll term vegetation octdinuoiisly saturated. 3 to 5 other seedvariettes Bralwintop Millet Uiroichkaramosa 1 10 lbs scil test 5111'-9120 SM5-811 15-811 Sun Yes yes No Cr22 should be clut / disc Not water tolerant. May be used grior to,i2j.erima ty or inwetlands -that eronot long term vegetation ocintinuomlysaturated. that have ;jfrdlar soil cVainage.adaptations, Sudan glissaftbLftjtS�hum sacMaWum. I 151ba By sollbog NR NR 4/15-8115 Sun No No Yoe Crop should be cut I Men Um only whsle plants and sad bico1crssA0ru:nmonciV prior to Yanting pftM or can be contained and contrdlod. LcM term vegetation irainage adaptaltioh,, IndiaiicraassCK1M5""VX&"1 "rM.V"X&1W8a Kobe LAVadezit iKummarowle sirlato x kobe 1 10 it BY so test 5/1 _'911 511""-911 511-811 Sun :No No No consultLualffm Use in 0castal Plain 1211-611 .911 -511 horticulluraft orextanslon NR: '01011 No agerd for ow -seedling Only Indiaricirass: aclaritab! to �yyitchgrass Paincuin- virclatun with pftw cover A Disoi! test 12/1-4/15 12/1-4,11 12/1-4,111 Korean L2NnLm KuiinmeAna sboalam 1 10 Itis 511.- 911 511-911 -Suri No. y3olltest, 511 9/1 No, Not Consult qualffled Use in Pledmont and Pespokids v4eii to Eastern coastal piain (Zone 91) hortioulltur" or extension Mourdalm MaVbeocime. N N2Ld for over-swoky irviiast" sit (-,irunarjejdapt hons Al, with prinuw cover A I on,v '10 .2 R-ce Cu[ -sass Loambcordd* Nee 6yscil test 1211-4115 1211'- 411 1`211 -Ail NOTES: 1. Seeding ratiors am for Wiled ased unless otherwise noted. 2. Forliltmr& Limestone - rates to be applied iritosense of soils tests. ReoulffmwrdadapplicaUmrate assumes sign 'Acan#y .dlsfurhad alta sobs with IidJe or;no residual value: 3, NR means Species not recommended for this region or application area. 4, invasive .designation as detemllned by the N.C. Ewft Past Pont Council and N.C. Nattvo Plant Sod*. 5, Spirfoging is not recommended farlimmadiate stabilization untwa terrain Is flat heavy mulch to applied and no other hmadiate stabilization method is practicall., 3 to < artier sect ~anotias HERBACEOUS PLANTS -Seeding reconu,nendations, for primary stabilization HERBACEOUS PLANTS -Seeding recommendations for primary stabilization Successfull development depends on, planting date (effectiveness goal: 6 L mo. - 3 yirs. without an ongoing maintenance program) NATIVE SPECIES 'Table 61,11„c Opfiinal Pfartino Dates Co-mmon Narne ;-_1,at1nPa�f.lA71Wr Botanical Name Cu War -.See Tabte "id for hjaWe Introduwd scedhngiates Fertilizationt' linrestone Itislaore Mountans Ptcarrim Cossial Pairs Sunt'Shade tolerant VIe.;avds Riparian Butfe;s Invasive Xes or No 1 staliation 1 n Maintenance, considerationi; .0therinformation- corrMi2nary ras, ylfgatum N 'A, ev suit test 1211-4/15 NR NP Sir, NP Vell dratne( No Pesreords "(ell 16 'Western mastal Plain only Cave-in-Rcck drained aontrrliedWMs �.4 X '4Bch onlv controlled burns, Mix with 'hv, 5de'd V, - I .3 10 " (.it Irietles 3 to 5 other seedvariettes that 'have similar soil that have ;jfrdlar soil cVainage.adaptations, irainage adaptaltioh,, IndiaiicraassCK1M5""VX&"1 "rM.V"X&1W8a N B By sotl test, NI, 1211-611 .911 -511 Sur, NR: '01011 No Resooniswell to Only Indiaricirass: aclaritab! to �yyitchgrass Paincuin- virclatun A Disoi! test 12/1-4/15 12/1-4,11 12/1-4,111 Sun NR Nall drainet No Pespokids v4eii to Eastern coastal piain (Zone 91) N sit (-,irunarjejdapt hons Al, A I on,v '10 .2 R-ce Cu[ -sass Loambcordd* Nee 6yscil test 1211-4115 1211'- 411 1`211 -Ail Sun 3 to < artier sect ~anotias P2S�L No Nixtivith 3 to 5 othel ��cl Warm season eras s- 5 U) 40� drained that have .,;miler soil Lanelies- ' that have snilar sal drainage adaptations di aina2e adaptation: Deertonque Diklier*iAm N C, to 511-411:" Si 1.- 411 1 0 S6r! Yes U� Net Re�.Drindswall to N Switch( 2rass: in - C4 A By soil test to 12,11-411 1211-4/1 Suri NR Vell draine, to Responds woi!rto Stolf'r dtain,'d "moties that have 4rrulpr me T- onlv Itt V seal dramaga '%clarations V_ 0 Vi Q111 a W Rye 46- !t!ko�_ N i By soil Ie5( 3/1 - 5116 �115 - 4,11 2115-3/20 Sun & N1 R weft that have sm)llar Mix voth 3 to5 other seed Cnoii season arass flS - 100 '911 '1nod 3, 11 r.Shade drained varietiesthal: have sirrolar -drains e adaptations, Big Blu-stam, f N D By soil test 1211-411 Qjl - 471 > to NR Well[ No, Respondsvitall to Warrn season crass '3witch2rass Parxurn wirciatur" I N A Ev $oil test 1211-4115 1211-4f1 1 i.4t1 Sun Yes Yes No Res 2onds wc!l to l3n -,)!15 2115 - 4.11 1 :NR Sun & Carthage loid, I NO Mix with 3 to 5 otner,sesd Cool seeaBon g I rass Grass 1,116-8115 dict -'1x3713 controlled bums. Mix with diained varieties that have 5irrjlar 3 to other seed varieties scNI drainag,-) sdal:itations thai have 5Ihi;lar soj! Soft Push Jcaras Nr K By sell test 12 11 - 5115 1211 -5/1 1211-4/15 Sur: Yes Poorly No Mx with 3 fo 5 01her seed dramage adaptations Pig slunisloll) 0 N D By sal test 7211-4175 12M - 40 NR 'Sur! NR '010111 No FK,,,W;,,n swell to War1r, season grass Switcrigrass fe.act...rp virgaturril 14 A E 3y=:test 12/1-,/15 12/1 - 411 1211-411, Sun No Poorly No Responds well to 1(anlow Shalloriv Sea te OmmkAch N L drained '2,", -5115 12/1 - 5!l 12,11.41'15, 5.% r- 2 ye,� poo�ly No h 1A xtviih '� ro 5 of. or, �-_-ed gil- 11/1 1 to 5�othir soed varieties varlefies thw have similar A:3 that have sirriila'soil E drainage adaptations Siq Blueaern &AM=gymal: N D B.salted. 1211-4115 1211 -bit 0 tvix vvith 3 to 5 other seed NR C! No Respondswell to Warm eason grass S,vitc hgrass Parcum virgat'ufr/ Q A %-soiltest 0 1211 - ,/I v-s'l Q03 No P000y No Ros tionds wall t Alamo H,.arli adaptations V U) q Cf) dr1ined (6 td C6 (o C14 3 to 5 otherseed v arjet,os vi 04 - to, N cv that have �,iirlllar Soll N�0 0 drainage adaptaltions. E By _,6,1 test 1211415 ?1R_ NR Sun, NP Well! 1lo P.e,pondstwell to W2rrn season grrvss Indiangrass 36,,qti�st,,ujn.nUtars N 6 Bv soil test 1211-Ail5_ 1211 _4/11 121 "ll $un NR ell No Restiondsvielit to Vvcsteln' oastal elan only Lo 0 C CL ii t3' • -h drin,,d controlledbums. Mix with to 5 other seed varieties 0 0 drainacieadaptatians. Little Bluestein N E_ �,sal tori 12/1416 1211 - 411 NR Sunz NR Well! No Resrioniswall to Warn season oress Indiangrass nulauls M B By soil test 1211-4JI5 1211-41,1 12/1-4/1 Zo NR Well No,Respond5well to 'Arn1pstacoastal plain only osa9c drained . . . . ...... conteoilQdburns Miywith 3 to,5 other seed varieties �5 QQ Z '0_0 W 0 Z that have similer soil draina2e adaptations: o J% E r 1.7 q LQ q 111 q U) U) CL _IMD 'C' r C,> co r1_ "i- C4 N (D C�l M I I I 0 of 0), Z tD Call 0 E Q 0) Ea) a) o a) o > L_ 'a 0 CO L E E_ 0 Z (D 0 :3 > LU T_ 5, > 'm L* 4 N :13E CiJ3 ID (D > .- 0 1>1 2A E J.D. O 0 3:, IR 1 .1 L a :P 0'- V 0 0 0) :3 E tw 1,D 0 a U to ca jof (CDL M 5 vi chZ 0 -0 0) 0 _j HERBACEOUS PLANTS -Seeding recommendations for primary stabilization Successfull development depends on, planting date (effectiveness goal: 6 L mo. - 3 yirs. without an ongoing maintenance program) NATIVE SPECIES 'Table 61,11„c HERBACEOUS, PLANTS -Seeding recomrnendations for primary, stabilization Successfull development depends on planting date (effectiveness goal* 6 mio. - 3 -yrs. without an,ongoing maintenance program) NATINIF _(;PF(`IF_1; Table 6.11'.1 (con't). I Opfiinal Pfartino Dates Co-mmon Narne ;-_1,at1nPa�f.lA71Wr Botanical Name Cu War -.See Tabte "id for hjaWe Introduwd scedhngiates Fertilizationt' linrestone Itislaore Mountans Ptcarrim Cossial Pairs Sunt'Shade tolerant VIe.;avds Riparian Butfe;s Invasive Xes or No 1 staliation 1 n Maintenance, considerationi; .0therinformation- corrMi2nary ras, ylfgatum N 'A, ev suit test 1211-4/15 NR NP Sir, NP Vell dratne( No Pesreords "(ell 16 'Western mastal Plain only Cave-in-Rcck drained aontrrliedWMs �.4 X '4Bch onlv controlled burns, Mix with 'hv, 5de'd V, - I .3 10 " (.it Irietles 3 to 5 other seedvariettes that 'have similar soil that have ;jfrdlar soil cVainage.adaptations, irainage adaptaltioh,, IndiaiicraassCK1M5""VX&"1 "rM.V"X&1W8a N B By sotl test, NI, 1211-611 .911 -511 Sur, NR: '01011 No Resooniswell to Only Indiaricirass: aclaritab! to �yyitchgrass Paincuin- virclatun A Disoi! test 12/1-4/15 12/1-4,11 12/1-4,111 Sun NR Nall drainet No Pespokids v4eii to Eastern coastal piain (Zone 91) N sit (-,irunarjejdapt hons I on,v lcontrolledbUrnsr t1IIXWjth R-ce Cu[ -sass Loambcordd* Nee 6yscil test 1211-4115 1211'- 411 1`211 -Ail Sun 3 to < artier sect ~anotias P2S�L No Nixtivith 3 to 5 othel ��cl Warm season eras s- drained that have .,;miler soil Lanelies- ' that have snilar sal drainage adaptations di aina2e adaptation: Deertonque Diklier*iAm N C, By soil test 511-411:" Si 1.- 411 1 NR S6r! Yes Pooriv Net Re�.Drindswall to N Switch( 2rass: Pancum VnIc"atum N A By soil test 12/1-4115 12,11-411 1211-4/1 Suri NR Vell draine, No Responds woi!rto Stolf'r dtain,'d "moties that have 4rrulpr onlv convo!'ed bum., -.I -Ax rich" seal dramaga '%clarations 3t 6 -therseed varieli o ol Vi Q111 a W Rye 46- !t!ko�_ N i By soil Ie5( 3/1 - 5116 �115 - 4,11 2115-3/20 Sun & N1 R weft that have sm)llar Mix voth 3 to5 other seed Cnoii season arass flS - 100 '911 '1nod 3, 11 r.Shade drained varietiesthal: have sirrolar -drains e adaptations, Big Blu-stam, f N D By soil test 1211-411 Qjl - 471 NR S.. NR Well[ No, Respondsvitall to Warrn season crass '3witch2rass Parxurn wirciatur" I N A Ev $oil test 1211-4115 1211-4f1 1 i.4t1 Sun Yes Yes No Res 2onds wc!l to l3n -,)!15 2115 - 4.11 1 :NR Sun & Carthage loid, I NO Mix with 3 to 5 otner,sesd Cool seeaBon g I rass Grass 1,116-8115 dict -'1x3713 controlled bums. Mix with diained varieties that have 5irrjlar 3 to other seed varieties scNI drainag,-) sdal:itations thai have 5Ihi;lar soj! Soft Push Jcaras Nr K By sell test 12 11 - 5115 1211 -5/1 1211-4/15 Sur: Yes Poorly No Mx with 3 fo 5 01her seed dramage adaptations Pig slunisloll) Amk� �_q-tffl N D By sal test 7211-4175 12M - 40 NR 'Sur! NR '010111 No FK,,,W;,,n swell to War1r, season grass Switcrigrass fe.act...rp virgaturril 14 A E 3y=:test 12/1-,/15 12/1 - 411 1211-411, Sun No Poorly No Responds well to 1(anlow Shalloriv Sea te OmmkAch N L drained '2,", -5115 12/1 - 5!l 12,11.41'15, controlled bums Mix with ye,� poo�ly No h 1A xtviih '� ro 5 of. or, �-_-ed gil- 11/1 1 to 5�othir soed varieties varlefies thw have similar that have sirriila'soil drainage adaptations Siq Blueaern &AM=gymal: N D B.salted. 1211-4115 1211 -bit 1211 -C,11Sun. tvix vvith 3 to 5 other seed NR wol No Respondswell to Warm eason grass S,vitc hgrass Parcum virgat'ufr/ N A %-soiltest NR 1211 - ,/I v-s'l Skin: No P000y No Ros tionds wall t Alamo H,.arli adaptations dr1ined controlieribums . Miik, wish 3 to 5 otherseed v arjet,os - `drama that have �,iirlllar Soll drainage adaptaltions. E By _,6,1 test 1211415 ?1R_ NR Sun, NP Well! 1lo P.e,pondstwell to W2rrn season grrvss Indiangrass 36,,qti�st,,ujn.nUtars N 6 Bv soil test 1211-Ail5_ 1211 _4/11 121 "ll $un NR ell No Restiondsvielit to Vvcsteln' oastal elan only • -h drin,,d controlledbums. Mix with to 5 other seed varieties that have similar soil drainacieadaptatians. Little Bluestein N E_ �,sal tori 12/1416 1211 - 411 NR Sunz NR Well! No Resrioniswall to Warn season oress Indiangrass nulauls M B By soil test 1211-4JI5 1211-41,1 12/1-4/1 Sun NR Well No,Respond5well to 'Arn1pstacoastal plain only osa9c drained . . . . ...... conteoilQdburns Miywith 3 to,5 other seed varieties that have similer soil draina2e adaptations: HERBACEOUS, PLANTS -Seeding recomrnendations for primary, stabilization Successfull development depends on planting date (effectiveness goal* 6 mio. - 3 -yrs. without an,ongoing maintenance program) NATINIF _(;PF(`IF_1; Table 6.11'.1 (con't). I HERBACEOUS PLANTS -Seeding recommendation's for primary stabilization Successfull development depends on planting date (effectiveness goal: 6 mo. - 3 yrs. without an ongoing maintenance program) NATIVE SPECIES Table 6.11r.C(con't) 0,tiroai Planlinq Dates Corm -non Name Sotarin>j! Name f 1 CUltivar See T.bl- Naive/ 6.11.d for ,,,j,_,y introcluced .(ttinq ratds Fertilizatiort' lira --stone lbsiacfa tw tain> P:,,d­t CO3sW P11- Surd5hade to;Arant Wetlands kpnnan Butters Invasive Yes or NoConsiderations it iWintenarice, Otherlilli0fri-13111r, CO m2nla y' rt Indiailloss 5CF1­105*11'rexAval N B 2,� soi, test 12/1-4/15, 1211 .41l 1211-4!1 Sun NRvvell No Re>Dondswell to controlled 'Western mastal Plain only drained aontrrliedWMs �.4 X '4Bch cmillp"I burns. Mixwith1to, 6 other seed 'hv, 5de'd V, - I .3 10 " (.it Irietles v*mehos that have, sinvar soil that 'have similar soil drainage adaptations. cVainage.adaptations, IndiaiicraassCK1M5""VX&"1 "rM.V"X&1W8a N B By sotl test, NI, 1211-611 .911 -511 Sur, NR: '01011 No Resooniswell to Only Indiaricirass: aclaritab! to mA. Shade well dmined vats Le t la,t have sirnilar dtained I ,)ntroiled burns. Mixmith Eastern coastal piain (Zone 91) sit (-,irunarjejdapt hons 3 to 6 other sced,variefies, R-ce Cu[ -sass Loambcordd* Nee 6yscil test 1211-4115 1211'- 411 1`211 -Ail Sun that have similar sell P2S�L No Nixtivith 3 to 5 othel ��cl Warm season eras s- drained drainageach tations. Lanelies- ' that have snilar sal drainage adaptations Deertonque Diklier*iAm N C, By soil test 511-411:" Si 1.- 411 1 NR S6r! Yes Pooriv Net Re�.Drindswall to N H By Soil t, 'Sl ��115 2" 1.5 4,11 14 1 t,- V Sun & NJR Shad- dral.led to loonLrolled bums., Mix with --st)-ade dtain,'d "moties that have 4rrulpr diou2nt 3 t 6 other seed varieties seal dramaga '%clarations that have similar soil Vi Q111 a W Rye 46- !t!ko�_ N i By soil Ie5( 3/1 - 5116 �115 - 4,11 2115-3/20 Sun & N1 R weft dr8inacpe adaptations. Mix voth 3 to5 other seed Cnoii season arass flS - 100 '911 '1nod 3, 11 r.Shade drained varietiesthal: have sirrolar Big Blu-stam, f N D By soil test 1211-411 Qjl - 471 NR S.. NR Well[ No, Respondsvitall to Warrn season crass EasterBcittjebrusll g 1 r a i ri. ed i controlled VIMG, M; ,XVAth l3n -,)!15 2115 - 4.11 1 :NR Sun & NR loid, I NO Mix with 3 to 5 otner,sesd Cool seeaBon g I rass Grass 1,116-8115 dict -'1x3713 ' 'to 6 other seed varieli . es diained varieties that have 5irrjlar that scNI drainag,-) sdal:itations drain gsada ptationo, Soft Push Jcaras Nr K By sell test 12 11 - 5115 1211 -5/1 1211-4/15 Sur: Yes Poorly No Mx with 3 fo 5 01her seed Pig slunisloll) Amk� �_q-tffl N D By sal test 7211-4175 12M - 40 NR 'Sur! NR '010111 No FK,,,W;,,n swell to War1r, season grass X3111i, soil drainage adaEalions drainod conliolled burns, Mix with Shalloriv Sea te OmmkAch N L By soil tesi. '2,", -5115 12/1 - 5!l 12,11.41'15, 6 other sped vwietie5 ye,� poo�ly No h 1A xtviih '� ro 5 of. or, �-_-ed gil- 11/1 1 that have Similar soil varlefies thw have similar drama ada0stions. Fox Sedge Siq Blueaern &AM=gymal: N D B.salted. 1211-4115 1211 -bit 1211 -C,11Sun. tvix vvith 3 to 5 other seed NR wol No Respondswell to Warm eason grass E.0 Itainedelie- that have. sunilat drained, Corirttledtisrr5. Mix witill H,.arli adaptations o other" seed varielies that nave similar soil - `drama nada nations. E By _,6,1 test 1211415 ?1R_ NR Sun, NP Well! 1lo P.e,pondstwell to W2rrn season grrvss drained Controlled burns, Mix,writh to 5 othei seed varieties that have similar soil drama adaptations. Little Bluestein N E_ �,sal tori 12/1416 1211 - 411 NR Sunz NR Well! No Resrioniswall to Warn season oress drained controlledburns. Mix with 3 to 5' otherseed varieties that nave Similar Soil Crainage adabtations. HERBACEOUS PLANTS -Seeding recommendation's for primary stabilization Successfull development depends on planting date (effectiveness goal: 6 mo. - 3 yrs. without an ongoing maintenance program) NATIVE SPECIES Table 6.11r.C(con't) NOTE: 1. Seeding rates are for hulled seed unless otherwise ncted,, 2. Fertilizer �& Limestcna: � rates t,,, be aj-,Wled un atnense of soils test-. rate assurries signficantiy distuibed site vah litIle or no iesiduai I value. 1 NR means Species not tecornmencied for this region applica•tion arasi, 4;Aalive, vlarm seas n gmss I osre, I quire six or inae, inonthsto germirtate under optirnum conditions. .1 they are planted in the surrimer, Ulan a vinoley ear.'will haveto pass b,�rcralhe'y gerrninate. C' the N.C. Exclic Pest Parit Council and N.C_ Native Plan', Society, 6. Sprigging is notrrcommenclod forimmodiato ctabilization unlessterfain isliat, heavyrrivich is applied and no other in-Innecliate stabilization 7, Sodding for i mpdtate,stalbilaalion - primary stabilizatic'n charts (other information column) and �W;cx,. 6.12 'in see P. Lon, lizwon.can only be iv.I term stabi acoomplishecl titrith an adequate� irnmediate, and primary stabilization proqtam; To achi&vt- Icnq tetail pr,Dlect cover With ffiespecieB listed in PERMANENT SEEDING PER NCDENR EROSION & SEDIMENT CONTROL PLANNING AND DESIGN MANUAL VERSION 6/06 (REVISED 3/09), SECTION 6.11 1. CHISEL COMPACTED AREAS AND SPREAD TOPSOIL 3 INCHES DEEP OVER ADVERSE SOIL CONDITIONS. IF AVAILABLE. 2. RIP THE ENTIRE AREA TO 6 INCHES DEPTH. 3. REMOVE ALL LOOSE ROCK, ROOTS, AND OTHER OBSTRUCTIONS LEAVING THE SURFACE REASONABLY SMOOTH AND UNIFORM. 4. APPLY AGRICULTURAL LIME, FERTILIZER AND SUPER PHOSPHATE UNIFORMLY AND MIX WITH SOIL. APPLY: AGRICULTURAL LIMESTONE - 2 TONS/ACRE (3 TONS/ACRE IN CLAY SOILS FERTILIZER - 1,000 LBS./ACRE - 10-10-10 SUPER PHOSPHATE - 500 LBS./ACRE - 20% ANALYSIS 5. CONTINUE TILLAGE UNTIL A WELL -PULVERIZED, FIRM, REASONABLY UNIFORM SEEDBED IS PREPARED 4 TO 6 INCHES DEEP. 6. SEED ON A FRESHLY PREPARED SEEDBED AND COVER SEED LIGHTLY WITH SEEDING EQUIPMENT CULTIPACK AFTER SEEDING. 7. MULCH IMMEDIATELY AFTER SEEDING AND ANCHOR MULCH WITH ASPHALT TACK. APPLY: MULCH - 2 TONS/ACRE - SMALL GRAIN STRAW ANCHOR - ASPHALT EMULSION @ 300 GALS./ACRE 8. INSPECT ALL SEEDED AREAS AND MAKE NECESSARY REPAIRS OR RESEEDINGS WITHIN THE PLANTING SEASON, IF POSSIBLE, IF STAND SHOULD BE OVER 60% DAMAGED, REESTABLISH FOLLOWING ORIGINAL LIME, FERTILIZER AND SEEDING RATES. 9. CONSULT CONSERVATION INSPECTOR ON MAINTENANCE TREATMENT AND FERTILIZATION AFTER PERMANENT COVER IS ESTABLISHED. FINAL DRAWING - RELEASED FOR CONSTRUCTION CO �4 0 Cq C0 Cj Coll 0 CCC' 1444 0 0 0 fr Z '48 M 18. co C4ti V, A% Wj �-4 oqCAR 2 0 X INS: N G. Z 0 aQ E-4 Z P.4 C) W E-4 Z > E-4 "'j C co 0 W Z '0 0 9 9 C4 1:1 Z 0 Z0 0 U 0 0-4 cri PROJECT NO. JPM-15010 FILENAME: JPM15010-EC3 DESIGNED BY: N D W DRAWN BY: DLP SCAM: N.T.S. DATE: 04-04-2016 SHEET NO. EC -3 !!JIMCADAMS CIpurnal Plantino, Dates Common Name 8otiN.,;9l Narne I Cultivw See"rable '631.d for liative, variety Intr!_ _�CluCed Se"irl Fenilizatonti. Westcoe IbSfZ�e ccsiai i4oun�,,i- P,,,,*ront Phiris Sun/Snade tcler3nt. �Netlarlds Riparian Buffers invastve je,,� of Na ln'T�:811ation I k/birneriance, Considerations 01h�* infUrnat'On. Little Bities,,erri 5dikactairkm N I By Foil test N. F% N R 1211 -All sun I N I', 1,Pj011 I N j Responds well to warm season cifass drained aontrrliedWMs �.4 X '4Bch 'hv, 5de'd V, - I .3 10 " (.it Irietles that 'have similar soil cVainage.adaptations, Sweet Woodreed "rM.V"X&1W8a N F By soll test 12,1-4115 1_.1:-.4!1 1:11-411 Sun & Yes Pool.. to r4 Mix rat 3 -to 5 other se -6d ,rand-: season grass mA. Shade well dmined vats Le t la,t have sirnilar sit (-,irunarjejdapt hons R-ce Cu[ -sass Loambcordd* Nee 6yscil test 1211-4115 1211'- 411 1`211 -Ail Sun N'eS P2S�L No Nixtivith 3 to 5 othel ��cl Warm season eras s- drained Lanelies- ' that have snilar sal drainage adaptations Indian Woodoats 41�� N H By Soil t, 'Sl ��115 2" 1.5 4,11 14 1 t,- V Sun & NJR --st)-ade dtain,'d "moties that have 4rrulpr seal dramaga '%clarations Vi Q111 a W Rye 46- !t!ko�_ N i By soil Ie5( 3/1 - 5116 �115 - 4,11 2115-3/20 Sun & N1 R weft No Mix voth 3 to5 other seed Cnoii season arass flS - 100 '911 '1nod 3, 11 r.Shade drained varietiesthal: have sirrolar SA I I orain;cie adaptations EasterBcittjebrusll g N i By soil test l3n -,)!15 2115 - 4.11 1 :NR Sun & NR loid, I NO Mix with 3 to 5 otner,sesd Cool seeaBon g I rass Grass 1,116-8115 dict -'1x3713 in Shade diained varieties that have 5irrjlar scNI drainag,-) sdal:itations Soft Push Jcaras Nr K By sell test 12 11 - 5115 1211 -5/1 1211-4/15 Sur: Yes Poorly No Mx with 3 fo 5 01her seed 8115_10115 °S7-1111 drained varieties thathaivesinnibr soil drainage adaEalions Shalloriv Sea te OmmkAch N L By soil tesi. '2,", -5115 12/1 - 5!l 12,11.41'15, Sun ye,� poo�ly No h 1A xtviih '� ro 5 of. or, �-_-ed gil- 11/1 1 drained varlefies thw have similar sol! .d,bin@9a adaptations Fox Sedge N L By sil test 1211 - 5115 12/1.'511 12/1-4/15 Sun Yes Poul y No tvix vvith 3 to 5 other seed a1I5_lQfl5 9111 , 111 Itainedelie- that have. sunilat H,.arli adaptations NOTE: 1. Seeding rates are for hulled seed unless otherwise ncted,, 2. Fertilizer �& Limestcna: � rates t,,, be aj-,Wled un atnense of soils test-. rate assurries signficantiy distuibed site vah litIle or no iesiduai I value. 1 NR means Species not tecornmencied for this region applica•tion arasi, 4;Aalive, vlarm seas n gmss I osre, I quire six or inae, inonthsto germirtate under optirnum conditions. .1 they are planted in the surrimer, Ulan a vinoley ear.'will haveto pass b,�rcralhe'y gerrninate. C' the N.C. Exclic Pest Parit Council and N.C_ Native Plan', Society, 6. Sprigging is notrrcommenclod forimmodiato ctabilization unlessterfain isliat, heavyrrivich is applied and no other in-Innecliate stabilization 7, Sodding for i mpdtate,stalbilaalion - primary stabilizatic'n charts (other information column) and �W;cx,. 6.12 'in see P. Lon, lizwon.can only be iv.I term stabi acoomplishecl titrith an adequate� irnmediate, and primary stabilization proqtam; To achi&vt- Icnq tetail pr,Dlect cover With ffiespecieB listed in PERMANENT SEEDING PER NCDENR EROSION & SEDIMENT CONTROL PLANNING AND DESIGN MANUAL VERSION 6/06 (REVISED 3/09), SECTION 6.11 1. CHISEL COMPACTED AREAS AND SPREAD TOPSOIL 3 INCHES DEEP OVER ADVERSE SOIL CONDITIONS. IF AVAILABLE. 2. RIP THE ENTIRE AREA TO 6 INCHES DEPTH. 3. REMOVE ALL LOOSE ROCK, ROOTS, AND OTHER OBSTRUCTIONS LEAVING THE SURFACE REASONABLY SMOOTH AND UNIFORM. 4. APPLY AGRICULTURAL LIME, FERTILIZER AND SUPER PHOSPHATE UNIFORMLY AND MIX WITH SOIL. APPLY: AGRICULTURAL LIMESTONE - 2 TONS/ACRE (3 TONS/ACRE IN CLAY SOILS FERTILIZER - 1,000 LBS./ACRE - 10-10-10 SUPER PHOSPHATE - 500 LBS./ACRE - 20% ANALYSIS 5. CONTINUE TILLAGE UNTIL A WELL -PULVERIZED, FIRM, REASONABLY UNIFORM SEEDBED IS PREPARED 4 TO 6 INCHES DEEP. 6. SEED ON A FRESHLY PREPARED SEEDBED AND COVER SEED LIGHTLY WITH SEEDING EQUIPMENT CULTIPACK AFTER SEEDING. 7. MULCH IMMEDIATELY AFTER SEEDING AND ANCHOR MULCH WITH ASPHALT TACK. APPLY: MULCH - 2 TONS/ACRE - SMALL GRAIN STRAW ANCHOR - ASPHALT EMULSION @ 300 GALS./ACRE 8. INSPECT ALL SEEDED AREAS AND MAKE NECESSARY REPAIRS OR RESEEDINGS WITHIN THE PLANTING SEASON, IF POSSIBLE, IF STAND SHOULD BE OVER 60% DAMAGED, REESTABLISH FOLLOWING ORIGINAL LIME, FERTILIZER AND SEEDING RATES. 9. CONSULT CONSERVATION INSPECTOR ON MAINTENANCE TREATMENT AND FERTILIZATION AFTER PERMANENT COVER IS ESTABLISHED. FINAL DRAWING - RELEASED FOR CONSTRUCTION CO �4 0 Cq C0 Cj Coll 0 CCC' 1444 0 0 0 fr Z '48 M 18. co C4ti V, A% Wj �-4 oqCAR 2 0 X INS: N G. Z 0 aQ E-4 Z P.4 C) W E-4 Z > E-4 "'j C co 0 W Z '0 0 9 9 C4 1:1 Z 0 Z0 0 U 0 0-4 cri PROJECT NO. JPM-15010 FILENAME: JPM15010-EC3 DESIGNED BY: N D W DRAWN BY: DLP SCAM: N.T.S. DATE: 04-04-2016 SHEET NO. EC -3 !!JIMCADAMS C E m Q m IR 0 N r` iJ O LO X iTANDARD METAL POSTS ?'-0" IN GROUND 3ALVANIZED HARDWARE WIRE _XTENDS TO TOP OF BOX NOTES: 1. TO BE USED AROUND YARD INLETS ------- ----------------------- -ACED _._._ -.ACED TO A HEIGHT OF 12"-18" MINIMUM ABOVE TOP OF BOX HARDWARE CLOTH & GRAVEL INLET PROTECTION EXISTING 6" MIN. ,.—STEEL P(W ,,--W6VEN WIRE FABRIC /WARNING MIN. 10 GRANGE, W RESISTANT UNE WIRES ' HIGH — TENSILE STRENGTH x POLY 1101I ME FABRIC (1YPiCW 50' NOTES: ML .� .,�:.. t. TREE PROTECTION AREA 1. PUT SILT FENCE OR TREE - PROTECTION FENCE UP TO IMMEDIATELY WITH TEMPORARY SEEDING ? ENSURE CONSTRUCTION COVER. INSTALL EROSION CONTROL 7, 4741 ENTRANCE IS USED. EXISTING No 2. IF CONSTRUCTION ON THE ROADWAY 2'-3STONE TO BE USED 20' SITES ARE SUCH THAT THE MUD 4` r a; IS NOT REMOVED BY THE 3, ' VEHICLE TRAVELING OVER THE ' HIGH — TENSILE STRENGTH , STONE, THEN THE TIRES OF THE POLY BARRICADE FABRIC (TYPICAL) VEHICLES MUST BE WASHED BEFORE ENTERING THE PUBLIC ROAD. PLAN VIEW SIDE VIEW NOTES: 35' MIN. 20 LB TENSILE STRENGTH FABRIC UNDER STONE CROSS SECTION 15' MIN. STANDARD CONSTRUCTION ENTRANCE B' MAX. VARIARI F AS nlPFCTEO RY THF FNGINFFR ao a DO NOT ENTER M TREE PROTECTION AREA WARNING SIGN DETAIL FRONT VIEW AREA PARA PROTECCION DE LOS ARBOLES PROHIBIDO ENTRAR 1. WARNING SIGNS TO BE MADE OF DURABLE, WEATHERPROOF MATERIAL. 2. LETTERS TO BE 3` HIGH MINIMUM, CLEARLY LEGIBLE AND SPACED AS DETAILED. 3. PLACE A SIGN AT EACH END OF LINEAR TREE PROTECTION AND 50' ON CENTER THEREAFTER. 4. FOR TREE PROTECTION AREAS LESS THAN 200' IN PERIMETER, PROVIDE NO LESS THAN ONE SIGN PER PROTECTION AREA. 5. ATTACH SIGNS SECURELY TO FENCE POSTS AND FABRIC. 6. MAINTAIN TREE PROTECTION FENCE THROUGHOUT DURATION OF PROJECT. 7. ADDITIONAL SIGNS MAY BE REQUIRED BY CITY OF RALEIGH BASED ON ACTUAL FIELD CONDITIONS. 6. SIGN SHALL BE IN BOTH ENGLISH AND SPANISH. TREE PROTECTION DETAIL NEW CONSTRUCTION NOTE: MINIMUM 10 GAUGE LINE 8'-0" MAXIMUM 1. USE SILT FENCE ONLY WHEN DRAINAGE AREA DOES NOT EXCEED 1/4 ACRE AND NEVER IN 12" MIN. AREAS OF CONCENTRATED FLOW. 2. REMOVE SEDIMENT DEPOSITED AS NEEDED TO PROVIDE STORAGE VOLUME FOR THE NEXT RAIN AND TO REMOVE PRESSURE ON THE SILT FENCE. 3. ALL SILT FENCE REQUIRED TO BE TRENCHED AT 6" MINIMUM. FRONT VIEW STEEL POST WOVEN WIRE FABRIC SILT FENCE FABRIC 3'-0 " F?u FILL SLOPE 26" � N GRADE Z 3m3'µ"i., ?xx ;x 6" MINIMUM COVER OVER SKIRT 2'-0 `ANCHOR SKIRT AS DIRECTED BY ENGINEER * SIDE VIEW STANDARD TEMPORARY SILT FENCE WIRE TIES ,._.� _ TOP ELEVATION OF STORMWATER ---'- '"""�---.�_ #57 WASHED STONE— MIN. 12-1/2 GA.? INTERMEDIATE EXISTING SLOPE.. WIRES RADE Figure 6.54a € ock doughnut inlet protection plan View and cross-section View_ ROCK DOUGHNUT INLET PROTECTION VG SLOPES ARIES— IES FRONT VIEW 1 RIP -RAP Q ,_i ) IES -FILTER FABRIC -VARIES- SIDE VIEW NOTE: 1. HEIGHT & WIDTH DETERMINED BY EXISTING TOPOGRAPHY AND SEDIMENT STORAGE REQUIRED. 2. KEY RIP RAP INTO THE DAM FOR STABILIZATION. -----KEYED RIP RAP 7 WASHED STONE EXISTING SLOPE STEP SEQUENCE CHECK DAM o CLASS 1 RIP RAP (SEE SECTION THRU BASIN BELOW) 3 � v a Yr INVEi�T�— RIP RAP HEADWALL WASHED STONE. 1'-0" THICK x 3'-0" HIGH if _ d ` MINIMUM F NOTES: PERSPECTIVE VIEW 1. GRAVEL & RIP RAP FILTER BERM BASIN NO SCALE DETAIL IS DESIGNED TO PROTECT EXISTING PIPE INVERTS THAT DRAIN 10 ACRES OR LESS. 2. DIMENSIONS ARE MINIMUM ACCEPTABLE Plea View AREAS TO BE DISTURBED SEDIMENT STORAGE UNLESS OTHERWISE NOTED. FLOOD STORAGE ZONE RIP RAP (CUT, FILL, ETC. HEADWALL 1 1 I PIPE O INVERT \� 1.5 3' I. 1.5 tl� CLASS 1 RIP -RAP MAXIMUM SEDIMENT DEPT (CLEAN OUT POINT) #5 WASHED STONE SECTION THRU BASIN FILTER AND CULVERT PIPE NO SCALE ROCK PIPE INLET PROTECTION NATURAL GROUND FLOW --r- TOP OF SILT FENCE MUST BE AT LEAST 1' ABOVE TH THE WASE IMUM 12-1/2 GAUGE _RMEDIATE WIRES GRADE STEEP CUT OR FILL NOTE: SILT FENCE OUTLETS TO BE INSTALLED EVERY 100 LF ALONG STEEL FENCE POST SILT FENCE WHEN SLOPES ARE7 DRAINING TOWARDS THE FENCE. SET MAX 2' APART MIN. 18" INTO SOLID GROUND STEEL FENCE POST WIRE FENCE HARDWARE CLOTH FILTER OF #57 \ WASHED STONE 3' FILTER FABRIC ON GROUND FENCE, RIC, Aiw mAKuWARE CLOTH IN TRENCH BURY WIRE FENCE AND HARDWARE CLOTH BURY 6" OF UPPER EDGE OF FILTER FABRIC IN TRENCH SECTION VIEW STANDARD SILT FENCE OUTLET 2' MIN. 3' tMIN. BOT WIDTH ARNING SIGN ML .� .,�:.. t. TREE PROTECTION AREA - IMMEDIATELY WITH TEMPORARY SEEDING ? DO NOT ENTER COVER. INSTALL EROSION CONTROL 7, 4741 MAT WHERE SHOWN ON PLANS. UPSLOPE TO No d f 2' MINIMUM SIDE SLOPE 2 1 (MAX IMUM)°� r a; 3, ' ORANGE, L1V RESISTANT ' HIGH — TENSILE STRENGTH , POLY BARRICADE FABRIC (TYPICAL) ao a DO NOT ENTER M TREE PROTECTION AREA WARNING SIGN DETAIL FRONT VIEW AREA PARA PROTECCION DE LOS ARBOLES PROHIBIDO ENTRAR 1. WARNING SIGNS TO BE MADE OF DURABLE, WEATHERPROOF MATERIAL. 2. LETTERS TO BE 3` HIGH MINIMUM, CLEARLY LEGIBLE AND SPACED AS DETAILED. 3. PLACE A SIGN AT EACH END OF LINEAR TREE PROTECTION AND 50' ON CENTER THEREAFTER. 4. FOR TREE PROTECTION AREAS LESS THAN 200' IN PERIMETER, PROVIDE NO LESS THAN ONE SIGN PER PROTECTION AREA. 5. ATTACH SIGNS SECURELY TO FENCE POSTS AND FABRIC. 6. MAINTAIN TREE PROTECTION FENCE THROUGHOUT DURATION OF PROJECT. 7. ADDITIONAL SIGNS MAY BE REQUIRED BY CITY OF RALEIGH BASED ON ACTUAL FIELD CONDITIONS. 6. SIGN SHALL BE IN BOTH ENGLISH AND SPANISH. TREE PROTECTION DETAIL NEW CONSTRUCTION NOTE: MINIMUM 10 GAUGE LINE 8'-0" MAXIMUM 1. USE SILT FENCE ONLY WHEN DRAINAGE AREA DOES NOT EXCEED 1/4 ACRE AND NEVER IN 12" MIN. AREAS OF CONCENTRATED FLOW. 2. REMOVE SEDIMENT DEPOSITED AS NEEDED TO PROVIDE STORAGE VOLUME FOR THE NEXT RAIN AND TO REMOVE PRESSURE ON THE SILT FENCE. 3. ALL SILT FENCE REQUIRED TO BE TRENCHED AT 6" MINIMUM. FRONT VIEW STEEL POST WOVEN WIRE FABRIC SILT FENCE FABRIC 3'-0 " F?u FILL SLOPE 26" � N GRADE Z 3m3'µ"i., ?xx ;x 6" MINIMUM COVER OVER SKIRT 2'-0 `ANCHOR SKIRT AS DIRECTED BY ENGINEER * SIDE VIEW STANDARD TEMPORARY SILT FENCE WIRE TIES ,._.� _ TOP ELEVATION OF STORMWATER ---'- '"""�---.�_ #57 WASHED STONE— MIN. 12-1/2 GA.? INTERMEDIATE EXISTING SLOPE.. WIRES RADE Figure 6.54a € ock doughnut inlet protection plan View and cross-section View_ ROCK DOUGHNUT INLET PROTECTION VG SLOPES ARIES— IES FRONT VIEW 1 RIP -RAP Q ,_i ) IES -FILTER FABRIC -VARIES- SIDE VIEW NOTE: 1. HEIGHT & WIDTH DETERMINED BY EXISTING TOPOGRAPHY AND SEDIMENT STORAGE REQUIRED. 2. KEY RIP RAP INTO THE DAM FOR STABILIZATION. -----KEYED RIP RAP 7 WASHED STONE EXISTING SLOPE STEP SEQUENCE CHECK DAM o CLASS 1 RIP RAP (SEE SECTION THRU BASIN BELOW) 3 � v a Yr INVEi�T�— RIP RAP HEADWALL WASHED STONE. 1'-0" THICK x 3'-0" HIGH if _ d ` MINIMUM F NOTES: PERSPECTIVE VIEW 1. GRAVEL & RIP RAP FILTER BERM BASIN NO SCALE DETAIL IS DESIGNED TO PROTECT EXISTING PIPE INVERTS THAT DRAIN 10 ACRES OR LESS. 2. DIMENSIONS ARE MINIMUM ACCEPTABLE Plea View AREAS TO BE DISTURBED SEDIMENT STORAGE UNLESS OTHERWISE NOTED. FLOOD STORAGE ZONE RIP RAP (CUT, FILL, ETC. HEADWALL 1 1 I PIPE O INVERT \� 1.5 3' I. 1.5 tl� CLASS 1 RIP -RAP MAXIMUM SEDIMENT DEPT (CLEAN OUT POINT) #5 WASHED STONE SECTION THRU BASIN FILTER AND CULVERT PIPE NO SCALE ROCK PIPE INLET PROTECTION NATURAL GROUND FLOW --r- TOP OF SILT FENCE MUST BE AT LEAST 1' ABOVE TH THE WASE IMUM 12-1/2 GAUGE _RMEDIATE WIRES GRADE STEEP CUT OR FILL NOTE: SILT FENCE OUTLETS TO BE INSTALLED EVERY 100 LF ALONG STEEL FENCE POST SILT FENCE WHEN SLOPES ARE7 DRAINING TOWARDS THE FENCE. SET MAX 2' APART MIN. 18" INTO SOLID GROUND STEEL FENCE POST WIRE FENCE HARDWARE CLOTH FILTER OF #57 \ WASHED STONE 3' FILTER FABRIC ON GROUND FENCE, RIC, Aiw mAKuWARE CLOTH IN TRENCH BURY WIRE FENCE AND HARDWARE CLOTH BURY 6" OF UPPER EDGE OF FILTER FABRIC IN TRENCH SECTION VIEW STANDARD SILT FENCE OUTLET 2' MIN. 3' tMIN. BOT WIDTH STANDARD DIVERSION DITCH l NOTES: 1. L = THE LENGTH OF THE RIPRAP APRON. 2. d = 1.5 TIMES THE MAXIMUM STONE DIAMETER BUT NOT LESS THAN 6" (inches). 3. IN A WELL-DEFINED CHANNEL EXTEND THE APRON UP THE CHANNEL BANKS TO AN ELEVATION OF 6" (inches) ABOVE THE MAXIMUM TAILWATER DEPTH OR TO THE TOP OF THE BANK, WHICHEVER IS LESS. A FILTER BLANKET OR FILTER FABRIC SHOULD BE PALLED BETWEEN THE RIPRAP AND SOIL FOUNDATION. SECTION 'A -A' FABRIC PIPE OUTLET TO WELL-DEFINED CHANNEL FINAL DRAIM1TTNG = RELE D � 0 T ,SSE R CONSTRUCTION M � QQ INd • D'N V M criC Z z10 O8 in p w BUS co i 04 S a A .`�% C _ L 2 80 qN G f H W a� a� E'+ �D LO W w r-4 0 0 W�, E­4 1��► > r, i Ha a 0 0 A a V1 CqO A v A A O ��0 ® z+ldgmmh� U) h V Q to PG•i �s w TQ V PROJECT NO. JPM-15010 FILENAME: JPM15010-EC3 DESIGNED BY: N D W DRAWN BY: DLP SCALE: N.T.S. DATE: 04-04-2016 SHEET NO. EC -4 'J MCA.DAM.S CROSS SECTION STABILIZE DIVERSION DITCH IMMEDIATELY WITH TEMPORARY SEEDING COVER. INSTALL EROSION CONTROL MAT WHERE SHOWN ON PLANS. UPSLOPE TO No d f 2' MINIMUM SIDE SLOPE 2 1 (MAX IMUM)°� STEEP CUT OR FILL SLOPE STANDARD DIVERSION DITCH l NOTES: 1. L = THE LENGTH OF THE RIPRAP APRON. 2. d = 1.5 TIMES THE MAXIMUM STONE DIAMETER BUT NOT LESS THAN 6" (inches). 3. IN A WELL-DEFINED CHANNEL EXTEND THE APRON UP THE CHANNEL BANKS TO AN ELEVATION OF 6" (inches) ABOVE THE MAXIMUM TAILWATER DEPTH OR TO THE TOP OF THE BANK, WHICHEVER IS LESS. A FILTER BLANKET OR FILTER FABRIC SHOULD BE PALLED BETWEEN THE RIPRAP AND SOIL FOUNDATION. SECTION 'A -A' FABRIC PIPE OUTLET TO WELL-DEFINED CHANNEL FINAL DRAIM1TTNG = RELE D � 0 T ,SSE R CONSTRUCTION M � QQ INd • D'N V M criC Z z10 O8 in p w BUS co i 04 S a A .`�% C _ L 2 80 qN G f H W a� a� E'+ �D LO W w r-4 0 0 W�, E­4 1��► > r, i Ha a 0 0 A a V1 CqO A v A A O ��0 ® z+ldgmmh� U) h V Q to PG•i �s w TQ V PROJECT NO. JPM-15010 FILENAME: JPM15010-EC3 DESIGNED BY: N D W DRAWN BY: DLP SCALE: N.T.S. DATE: 04-04-2016 SHEET NO. EC -4 'J MCA.DAM.S UNUKOIN UP FLEA u •' �2 SKIMMER SEDIMENT BASIN BAFFLES WITH METAL POSTS, - WOVEN WIRE FABRIC BACKING, AND COIR FIBER -RETRIEVAL NETTING 18"PE SKIMMER 15' PROVIDE HIGH STRENGTH _-CMMIN IN SPOUT HIGH STRENGTH STRAPPING FOR HOLDING HOSE IN PLACE WATER FLOW FROM PUMP OPENING TO ACCOMMODATE UP TO 4" DISCHARGE HOSE (3"THICK �NCDOT NO. •57 STONE) NOTES: 1. THE DEWATERING BAG SHALL BE MADE OF NON -WOVEN GEOTEXTILE WITH A MIN. SURFACE AREA OF 225 SQUARE FEET PER SIDE. 2. ALL STRUCTURAL SEAMS SHALL BE SEWN WITH A DOUBLE STITCH USING A DOUBLE NEEDLE MACHINE WITH HIGH STRENGTH THREAD. 3. THE SEAM STRENGTH SHALL WITHSTAND 100 LB/IN USING ASTM D-4884 TEST METHOD. 4. THE GEOTEXTILE FABRIC SHALL BE 10 OZ NON -WOVEN FABRIC 5. DISCHARGE FROM THE DEWATERING BAG SHALL BE DIRECTED SUCH THAT PRE -DISTURBANCE HYDROLOGY IS NOT CHANGED. DIRT BAG DETAIL ( PROTECT WEIR F 25% NOTE: HORIZONTAL STAPLE SPACING SHOULD BE ALTERED IF NECESSARY TO ALLOW STAPLES TO SECURE THE CRITICAL POINTS ALONG THE CHANNEL SURFACE. CRITICAL POINTS WITH FILTER FILTER , 25% REFER TO GENERAL STAPLE PATTERN GUIDE FOR a OVERLAPS AND SEAMS FABRIC POSTS F �o�, CORRECT STAPLE RECOMMENDATIONS FOR CHANNELS. B. PROUECTED WATER LINE FABRIC &RIP D E TH 15% C. CHANNEL BOTTOM/SIDE "C" _ INSTALL USING STAPLE PATTERN SLOPE VERTICES RAP 4" OR 6" PVC ' PER MANUFACTURER 5'x3'x18" 6" STONE APRON ENGT SKIMMER BASIN CROSS SECTION NOTES: 1. USE FOR DRAINAGE AREAS NOT EXCEEDING 10 ACRES. 2. EARTH BERM SHALL BE STABILIZED WITH VEGETATION ACCORDING TO TOWN SPECIFICATIONS. 3. INSPECT TEMPORARY SEDIMENT BASINS AND EMPTY SKIMMER OF ALL DEBRIS AFTER EACH PERIOD OF SIGNIFICANT RAINFALL. REMOVE SEDIMENT AND RESTORE BASIN TO ITS ORIGINAL DIMENSIONS WHEN THE SEDIMENT HAS ACCUMULATED TO ONE-HALF THE DESIGN DEPTH OF THE BASIN. PLACE THE SEDIMENT THAT HAS BEEN REMOVED IN A DESIGNATED DISPOSAL AREA. REPAIR AND/OR REPLACE BAFFLES. 4. CHECK THE STRUCTURE FOR DAMAGE FROM EROSION OR PIPING. PERIODICALLY CHECK THE DEPTH OF THE SPILLWAY TO ENSURE IT IS A MINIMUM OF 1.5 FEET BELOW THE LOW POINT OF THE EMBANKMENT. IMMEDIATELY FILL ANY SETTLEMENT OF THE EMBANKMENT TO SLIGHTLY ABOVE DESIGN GRADE. ANY RIP RAP DISPLACED FROM THE SPILLWAY MUST BE REPLACED IMMEDIATELY. 5. STABILIZE THE EMBANKMENT AND ALL DISTURBED AREAS ABOVE THE SEDIMENT POOL AND DOWNSTREAM FROM THE TRAP IMMEDIATELY AFTER CONSTRUCTION WITH SEEDING. 6. FLOW ENTERING THE BASIN MUST BE DIRECTED TO AVOID EROSION ALONG THE SLOPE AND SCOUR IN THE BASIN. APPROPRIATELY SIZED SLOPE DRAINS, PER THE STANDARD DETAIL, ARE RECOMMENDED. SKIMMER SEDIMENT BASIN CONCRETE BMP RISER. SEE DETAIL SHEET FOR DIMENSIONS. WATER LEVEL SKIMMER DURING STORM SEDIMENY „STORAGE ORIFICE ANTI -FLOATATION DEVICE ANTI -SEEP COLLAR CROSS SECTION w EMERGENCY SPILLWAY CONSTRUCTED OVER UNDISTURBED GROUND AND ARMORED WITH RIP RAP= - 1'-0" MINIMUM EARTH RCP OUTLET PIPE 1�I.1�lL9h1�i9 TOP OF DAM EMERGENCY SPILLWAY ELEVATION 7 MINIMUM SLOPES 2-1/2 : 1 DISSIPATER PAD RIP RAP EARTH DAM DISSIPATER PAD RIP RAP STANDARD RISER -BARREL SEDIMENT BASIN (WITH SKIMMER) xl PERSPECTIVE VIEW NTS CONSTRUCTION SPECIFICATION 1. GRADE THE BASIN SO THAT THE BOTTOM IS LEVEL FRONT TO BACK AND SIDE TO SIDE. 2. INSTALL POSTS OR SAW HORSES ACROSS THE WIDTH OF THE SEDIMENT TRAP. 3. STEEL POSTS SHOULD BE DRIVEN TO A DEPTH OF 24 INCHES, SPACED AT A MAXIMUM OF 4 FEET APART, AND INSTALLED UP THE SIDES OF THE BASIN AS WELL. THE TOP OF THE FABRIC SHOULD BE 6 INCHES HIGHER THAN THE INVERT OF THE SPILLWAY. TOPS OF BAFFLES SHOULD BE 2 INCHES LOWER THAN THE TOP OF THE BERM. 4. INSTALL AT LEAST THREE ROWS OF BAFFLES BETWEEN THE INLET AND OUTLET DISCHARGE POINT. 5. WHEN USING POSTS, ADD A SUPPORT WIRE OR ROPE ACROSS THE TOP OF THE MEASURE TO PREVENT SAGGING. 6. WRAP POROUS MATERIAL, LIKE JUTE BACKED BY COIR MATERIAL, OVER A SAWHORSE OR THE TOP WIRE. HAMMER REBAR INTO THE SAWHORSE LEGS FOR ANCHORING. THE FABRIC SHOULD HAVE FIVE TO TEN PERCENT OPENINGS IN THE WEAVE. ATTACH FABRIC TO A ROPE AND A SUPPORT STRUCTURE WITH SIP TIES, WIRE, OR STAPLES. 7. THE BOTTOM AND SIDES OF THE FABRIC SHOULD BE ANCHORED IN A TRENCH OR PINNED WITH 8 INCH EROSION CONTROL MATTING STAPLES. 8. DO NOT SPLICE THE FABRIC, BUT USE A CONTINUOUS PIECE ACROSS THE BASIN. OUTLET END: CONNECTION TO OUTLET PIPE OR RISER POROUS BAFFLE INSTALLATION DETAIL Yal Y7zY�7aY>DJ' 4 1. PREPARE SOIL BEFORE INSTALLING BLANKETS, INCLUDING APPLICATION OF LIME, FERTILIZER, AND SEED. 2. BEGIN AT THE TOP OF THE CHANNEL BY ANCHORING THE BLANKET IN A 6" DEEP X 6" WIDE TRENCH. BACKFILL AND COMPACT THE TRENCH AFTER STAPLING. 3. ROLL CENTER BLANKET IN DIRECTION OF WATER FLOW ON BOTTOM OF CHANNEL. 4. PLACE BLANKETS END OVER END (SHINGLE STYLE) WITH A 6" OVERLAP. USE A DOUBLE ROW Or STAGGERED STAPLES 4" APART TO SECURE BLANKETS. 5. FULL LENGTH EDGE OF BLANKETS AT TOP OF SIDE SLOPES MUST BE ANCHORED IN 6" DEEP X 6" WIDE TRENCH. BACKFILL AND COMPACT THE TRENCH AFTER STAPLING. 6. BLANKETS ON SIDE SLOPES MUST BE OVERLAPPED 4" OVER THE CENTER BLANKET AND STAPLED (2" FOR C350 MATTING). 7. IN HIGH FLOW CHANNEL APPLICATIONS, A STAPLE CHECK SLOT IS RECOMMENDED AT 30 TO 40 FOOT INTERVALS. USE A ROW OF STAPLES 4" APART OVER ENTIRE WIDTH OF THE CHANNEL. PLACE A SECOND ROW 4" BELOW THE FIRST ROW IN A STAGGERED PATTERN. 8. THE TERMINAL END OF THE BLANKETS MUST BE ANCHORED IN A 6" DEEP X 6" WIDE TRENCH. BACKFILL AND COMPACT THE TRENCH AFTER STAPLING. FOR PRODUCT INSTALLATION & INFORMATION QUESTIONS CONTACT MANUFACTURER AT: NORTH AMERICAN GREEN 14649 HIGHWAY 41 NORTH, EVANSVILLE, INDIANA 47711 USA 2-2040 CANADA 1-800-448-2040 INSMIAMON OF NORM -77At MMICAN GREEN CHADML INNER DIVERSION DIKE 4' MIN ;ISLAND OVER INLET DOR ".::.•.•� :;Ja,;�;o: ;:.;ti^.. 1.5' MIN HOLD-DOWN STAKES UNLET (I I -ILII kT PLASTIC CORRUGATED PIPE ( p TOP OF HAND -COMPACTED ff -) I FILL (ISLAND) STABILIZE I 4' min 0.5' min " OUTLET e t II I D� ERSIN 1 3 NATURAL GROUND 1 MI . III _III- 1.5' MIN. 3:1 { 3' I 4' MIN 1 Lp DIVERSION CHANNEL �� nen CC/�TI/1At TEMPORARY SLOPE DRAIN FINAL DRAWING - RELEASED FOR CONSTRUCTION co o ✓iNMV Ci Lo N d z 01-1 0 2z 22 b o -819 A � V V N A ' i 2 80 - qN G• 'JlJtilitti t 0 �q aQ a� Ea Lo W W .-a z cU owoC\2 � Cc F100 a w � O A a �- 0 z z0 0 cq � Q A W 0z w A V to w a� V PROJECT NO- JPM-15010 FILENAME: JPM15010-EC3 DESIGNED BY: N D W DRAWN BY: DLP SCALE: N.T.S. DATE: 04-04-2016 SHEET N0. E Co%; 5 '.P MCADAMS � - CLEAR SPAN LEVEL VP'WE9:ADER STRUCTURE (SEE- BLIND �.�.. .°�. �. � GRAVEL �rvir m°m/pvmm�� mnu � &CCE3S EASEMENT ~ ENGINEERED FILTER SMP . \ SEE DETAIL 1/SW1—B1 BL = 326.00 co 04 327 .329 PIPE 0 1.16% 332 334 EL. 325.00 r \ � ` 235 LFNCD0TCLASS 8 —�\ `` `r \ \ \ mp�^p nv�^�� ru^mm,` \ `~~--~~~ ~` GENERAL NQIE�j: 1. THE LEVEL SPREADER STRUCTURE SHALL BEINSTALLED 0NA ZERO PERCENT GRADE. 2. THE FIBERGLASS ANGLE SHALL BE INSTALLED (BOLTED TO THE CONCRETE LEVEL SPREADER STRUCTURE) ONLY AFTER A PRELIMINARY AS—BUILT (BASED ON A FIELD SURVEY OF THE CONSTRUCTED CONDITION OF THE LEVEL SPREADER STRUCTURE) HAS BEEN PREPARED AND SPECIFIC DIRECTION FROM THE DESIGN ENGINEER CONCERNING THE INSTALLATION OF THIS ELEMENT HAS BEEN PROVIDED. THE FIBERGLASS ANGLE SHALL BE SAWED—OFF TO THE LENGTHS SPECIFIED IN THE PLANS AND SHALL BE INSTALLED PERFECTLY LEVEL AT THE ELEVATIONS SPECIFIED IN THE PLANS (OR AT THE ADJUSTED ELEVATIONS SPECIFIED BY THE DESIGN [NC|W[ER). I UNLESS DIRECTED BY THE ONSITE GEOTECHNICAL ENGINEER, THE CONCRETE LEVEL SPREADER STRUCTURE SHAH L BE CONSTRUCTED ON UNDISTURBED SO|L, AND NOT ON FILL. 4. THE TRIANGULAR BUND SWALE SHALL BE CONSTRUCTED ON A ZERO PERCENT GRADE. 5. THE BLIND SWALE SHALL BE PLANTED NTH PICKEREL WEED. 0. THE 3—INCH LAYER OF #57 STONE SHALL BE UNDERLAIN WITH M|RAR RLTERWEAV[ 400 OR ENGINEER APPROVED EQUIVALENT. 7. 30' SODDED (NON ENGINEERED FILTER STRIP. SOD TO BE INSTALLED OVER O~ (MIM) LAYER OF TOPSOIL B. ENGINEERED FILTER STRIP SHALL BE INSTALLED NTH A O% CROSS—SLOPE AND A MAXIMUM 8YJSLOPE IN THE DIRECTION OF FLOW. FINAL DRAWING — NOT RELEASED FOR CONSTRUCTION NCDOT CLASS "B" RIPRAP NCDOT CLASS "B" RIPRAP TOP OF MARINE PLYWOOD WEIR = EL. 331.00 0 J LL- T /\—r / i\I�JJVf\L PLAN VIEW TREATED POSTS (TYP.) 12'-6" DOUBLE LAYER OF Y2" MARINE GRADE PLYWOOD h' 3t U�>�:;= Q V/z CREST OF MARINE PLYWOOD WEIR EL. 330.00 <'�: t 'Q''�•• ti - I I ..°� c,5_ ••cam c� � �;,-,l"�°�:,�`.::'kd � ~`� �' ��'.`.�,i''• •-`'..�a :�,i`. "�,C'- . t> {.. c� : • ____-_ I •. •' ..: ... ''. ::' .•. : •:�• •' •. •. ••' • tet- .. .. 'i .. t -.. .. _ S I I I I I I s .. .. •' , .t . ' : .t •-•• • •:•--•ti � •••� I I_m-.•_ •• y. t • .s, •. ... •� •• _ F ITT PIPE T S E .329.00 ____ _.� :. - .. ..:•.. ..• ... , ..�`::.: •-t = -• •. INV. OF 8 LOW SPLITTER E O L L I I I I I • •' i� ,t tII y t I—•--- I I _ - . •.. 111---I I 'i.• .. lil�-..III .. I .. .., . 5;. .. t' • `I i I I I I I-II I it 11111 III =1 I ISI I ISI I ISI E 1=I i I III I� i- I I ISI I ISI I ISI 1 1. 1 1 1 1 III=1 I ISE 11= ! I I =1 I I I=` 1 I ISI I ISI I I ISI 11=1 I ISI I 1=III -1 I I.'_►1 I-1 I I ISI =� � � �-� � �-� ► � �I ! I -11 I�I 11=11 I�1 III= BOTTOM OF PRESSURE TREATED 4"X4" POSTS = EL. 327.00 ^Iii=1 I— 1-- I I I-1 11-1 } I �,--I I®I 1-1 I I --1 11-1 I I II I I t 111— I� I Iv 4"X4" PRESSURE _ —I I I I_�-._.I I I -I 11�-1 I II I ISI 111 11-� E ISI _ I TREATED POSTS (TYP.)_ -- -911=1 I i=I 11-1 I I -III --I I I T-1 11=! ! 1=1 I I= I ISI 11=1 I I =1 11= 11 I I� FRONT VIEW' _hiC�Il�i A FILTER BLANKET IS TO BE INSTALLED BETWEEN THE RIPRAP AND SOIL FOUNDATION. THE FILTER BLANKET WILL CONSIST OF A MINIMUM 4" THICK LAYER OF STONE (NCDOT #57) UNDERLAIN WITH MIRAFI FILTER WEAVE 700 OR APPROVED EQUIVALENT EXISTING GROUND 1:1 SIDE SLOPE (TYP) (III N o = 6)) (MIN.) 'II � III=11 o {III 1= i I o III' I- MIRAFI FILTER 16 THICK NCDOT WEAVE 700 OR . � I — — — I i I � I ►— CLASS B RIP RAP APPROVED 6' MIN BOTTOM WIDTH EQUIVALENT FILTER BLANKET (SEE NOTE) 5 IX*ZD IS BYPAW CHANNEL S W1 — C N.T.S. 3 PL / U . -C 1 "=1' NOTES; PN�ineG^.t�No!e ^ n*«maax w u• creno: nscn"n:ov mwr�sa P w.ic Standard may rot eo irorvSmBtce .epmeucW veAtwN oxp:ess, wrt:m .r.. <-.,e.... u. 1. REINFORCEMENT: - GRADE 60 ASTM A-615 2676 US 1 HWY CY tet' .... 2. CONCRETE: P Box N ,�,•:,,.. 4' Level S rra(919)4.Nc = Spreader j - 4000 PSI @ 28 DAYS 3. DIMENSIONAL TOLERANCE +1" 4. CONTRACTOR RESPONSIBLE FOR LOCATING, LEVELING Fax (919) 49h-7616 & ASSEMBLING COMPONENTS 5. CONTRACTOR TO FILL LIFTING & ASSEMBLY POCKETS WITH GROUT AND SAND IF REQUIRED � 6. WEIGHTS AS FOLLOWED: - LEVEL SPREADER: 1,500 LBS. I 9. 12.5°1 4'-4" 4" — - 3'-10" — 1 , NCDOT STANDARD 838.80 - CONCRETE ENDWALL FOR 12" DIA PIPES EL. = 329.00 —1 111-111-1 ill -1 11.=11 I-1 11 LF OF 8" DIA DIP 04.54% EL. = 328.50 (74 = SW1—C N.T.S. DOUBLE LAYER OF Y2" MARINE GRADE PLYWOOD (BOLTED TO 4"X4" POSTS WITH Y4"X6" CARRIAGE HEAD BOLTS [3 EA PER POST]) NCDOT CLASS "B" RIPRAP 91 2,_0„ 6 2,-0„ f ---- 3'-8" 6" — _ _ t ---6" �— 41.4„ , Type „A„ Filename: SAO 1-Engineering\01-Stock Production\12-Level Spreader\Level Spreader --- 4'-2" _f 3'-8" 6" Type "B" LEM 1:03 PN�ineG^.t�No!e ^ n*«maax w u• creno: nscn"n:ov mwr�sa P w.ic Standard may rot eo irorvSmBtce .epmeucW veAtwN oxp:ess, wrt:m .r.. <-.,e.... u. QTY 2676 US 1 HWY CY tet' .... P Box N ,�,•:,,.. 4' Level S rra(919)4.Nc = Spreader k . amzola Phone(919)4947660 - �L 4 Fax (919) 49h-7616 GENERAL NOTES: 1. CONTRACTOR TO CONNECT BOTH 4—FT AND 8—FT LEVEL SPREADER TOGETHER PER LINDSAY PRECAST RECOMMENDATION 2. CONTRACTOR TO ENSURE THAT THE PRE—CAST LEVEL SPREADER SECTIONS ARE INSTALLED SUCH THAT THE ENTIRE LEVEL SPREADER IS LEVEL. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE THAT t 4"X4" PRESSURE TREATED POSTS (TYP.) FLOW N/A Q Q �Q Q ' ,--� � I--11►�I I ,�� � I�� I E , I C I �-�I I I ;III , ; . � I ;�I I �vl I !�- � I I- I -1 =,1 I I-- �1i1 =1il�I I l E — SECTION VIEW 24" 9„ 2" 0 9" 6" -1 -1 1--4" 42" 6" 6" 6" (-- 6„ 4 —24"- 24" --24" THE ENTIRE LEVEL SPREADER HAS A ZERO PERCENT GRADE AND THAT ANY PRE—CAST SECTIONS ARE WATERTIGHT WITH NO GAPS. 6WiDSAY PRECAST LEVEL SPREADER S W1- C N.T.S. — 96" REINFORCEMENT: 4 x 4 WIRE MESH W4 x W4 CENTERED BASE & WALL 15" 0P {NV \ OUT =322.0O NCD LASS B AP FOREBAY FILTER SMP- --- STREAM BUFFER ' 5'DIAMETER FLOW SPLITTER (SEE DETAIL 3/3W2�-C 30^ RCP INV IN = 323'30 15" 0P INV OUT = 323.25 30^ BYPASS RCP INV OUT = 324.00 \ '/ f6.00.08LF- 15r 0P 0 4.817. 328 / 3,0 / 0 . ' / -'- 18 LF_ 30^ " 0 3`12% MAINTENANCE' AND . ACCESS EASErT DIAMETER MANHOLE .�' " '~~ 15DIP INV UV = 321.50 ^ 30- RCP INV OUT 321.40 30" RCP INV OUT 320.00 J / � / 66 LF NCDOT CLASS 8 --^ RIPRAP BYPASS CHANNEL (SEE DETAIL 5/SW2-Cl / ' / . / ` \ \ \ \ . \ GENERAL NOTES: 1. THE LEVEL SPREADER STRUCTURESHALL BEINSTALLED 0NA ZERO PERCENT GRADE. 2. THE FIBERGLASS ANGLE SHALL BE INSTALLED (BOLTED TO THE CONCRETE L[VEL SPREADER STRUCTURE) ONLY AFTER A PRELIMINARY AS -BUILT (BASED ON A FIELD SURVEY OF THE CONSTRUCTED CONDITION OF THE LEVEL SPREADER STRUCTURE) HAS BEEN PREPARED AND SPECIFIC DIRECTION FROM THE DESIGN ENGINEER CONCERNING THE |NSTALLA11ON OF THIS ELEMENT HAS BEEN PRONDED, THE FIBERGLASS ANGLE SHALL BE SAWED-OFF TO THE LENGTHS SPECIFIED IN THE PLANS AND SHALL BE INSTALLED PERFECTLY LEVEL AT THE ELEVATIONS SPECIFIED IN THE PLANS (OR AT THE ADJUSTED ELEVATIONS SPECIFIED BY THE DESIGN ENGINEER). J. UNLESS DIRECTED BY THE ONSITE GEOTECHNICAL ENGINEER, THE CONCRETE LEVEL SPREADER STRUCTURE SHALL BE CONSTRUCTED ON UNDISTURBED SOIL, AND NOT ON RLL 4` THE TRIANGULAR BLIND SWALE SHALL BE CONSTRUCTED ON A ZERO PERCENT GRADE. 5. THE BLIND SVWALE SHALL BE PLANTED WITH PICKEREL WEED. 6. THE 3 -INCH LAYER OF #57 STONE SHALL BE UNDERLAIN NTH M|RAR RLTERWEAVE 400 OR ENGINEER APPROVED EQUIVALENT. 7. JO' SODDED (NON -CLAYEY) ENGINEERED FILTER STRIP. SOD TO BE INSTALLED OVER 8~ (MIM) LAYER OF TOPSOIL 8, ENGINEERED FILTER STRIP SHALL BE INSTALLED WITH A 0% CROSS -SLOPE AND A 2% SLOPE IN THE DIRECTION OF FLOW. FINAL DRAWING - NOT RELEASED FOR CONSTRUCTION 5'0 (INSIDE DIMME" '^"% CONCRETE JUNCTI MANHOLE RING AND COVER ACCESS 12.0 DIP (TO SAND FILTE INV. OUT = 332.50 5'0 (INSIDE DIMMENSION) CONCRETE JUNCTION BOX 15.0 DIP (TO LEVEL SPREADER) INV. OUT = 322.25 30"0 RCP INV. OUT = 321.40 30"0 RCP INV. IN = 331.50 RCP INV. = 321.40 MANHOLE RING AND COVER (T/C TO BE SET BY CONTRACTOR) CONTRACTOR SHALL PROVIDE STEPS IN ACCORDANCE WITH NCDOT STD. 840.66 (SEE DETAIL). STEPS SHALL BE PLACED AT 16" O.0 (TYP.) 5' 16" THICK NCDOT CLASS "B" RIP RAP FILTER BLANKET (SEE NOTE) NOTE: A FILTER BLANKET IS TO BE INSTALLED BETWEEN THE RIPRAP AND SOIL FOUNDATION. THE FILTER BLANKET WILL CONSIST OF A MINIMUM 4" THICK LAYER OF STONE (NCDOT #57) UNDERLAIN WITH MIRAFI FILTER WEAVE 700 OR APPROVED EQUIVALENT EXISTING GROUND 6" (MIN. 1:1 SIDE SLOPE (TYP) I- 6' MIN BOTTOM WIDTH . ry .. I 1 0 l f- ( -f) (I- 6" (MIN.) -) I -I' MIRAFI FILTER WEAVE 700 OR APPROVED EQUIVALENT NOTES: 1. REINFORCEMENT: - GRADE 60 ASTM A-615 2. CONCRETE: - 4000 PSI @ 28 DAYS 3. DIMENSIONAL TOLERANCE t1" 4. CONTRACTOR RESPONSIBLE FOR LOCATING, LEVELING & ASSEMBLING COMPONENTS 5. CONTRACTOR TO FILL LIFTING & ASSEMBLY POCKETS WITH GROUT AND SAND IF REQUIRED 6. WEIGHTS AS FOLLOWED: 1 - LEVEL SPREADER: 1,500 LBS. -- 91, 1- 4" 3'-6" 3 i i 1 6'' L -! 6"- 12.5° 2" i_ 6" 2'-0" I I� i I 4'-4" -I !_____3'-10" jyRe„A” Filename: S:\01-Engineering\01-Stock Production\12-Level Spreader\level Spreader 6" t _ 9„ �T F ` i 66" 2'-0„ ! � T 3'-8" 6" -- 3'-8"--- 6°I-- TYEE� „B" ME) Tboinlo li. Wnta's,ed Nrem,s tho P.a. ty«UWM yP�c:as,. `I Standard maY noS tto tronsmtied or rePfnduWd wltroui exWes�. wrY.(m x„,���� QTY o.c p¢rmFs6n. 2675 US t Km mVCY .•. ��-.na,» FPL.. 8” 580 P.O. ml.530 '_.,....... ~,.. me 4' Level Spreader 382074 Phona(g74)4N-600 'LS4 `. Fax(9t9)494-9816 •,. GENERAL NOTES: 1. CONTRACTOR TO CONNECT BOTH 4—FT AND 8—FT LEVEL SPREADER TOGETHER PER LINDSAY PRECAST RECOMMENDATION 2. CONTRACTOR TO ENSURE THAT THE PRE—CAST LEVEL SPREADER SECTIONS ARE INSTALLED SUCH THAT THE ENTIRE LEVEL SPREADER IS LEVEL. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO ENSURE THAT THE ENTIRE LEVEL SPREADER HAS A ZERO PERCENT GRADE AND THAT ANY PRE—CAST SECTIONS ARE WATERTIGHT WITH NO GAPS. Pnt V Con—to Products Since 1937 .vww.xWyAght.com CUSTOMER: QUANTITY: OF JOB WEIGHT: 2,700 LBS. LOCATION: SECTION: SIZE: Tx 8' LEVEL SPREADER DRAWN BY: 2W 9/18/08 PROJECT MGR: 7/zl9 * DO NOT FLIP WORKUP OVER * MAKE SURE JOINT IS CORRECT r. 9, �4„ —J 9" 2" 96" 6"- File -a SACADVAIso D,aMllgskLEVEL SPREADER 6" 96" --'16" REINFORCEMENT: 4 x 4 WIRE MESH W4 x W4 CENTERED BASE & WALL ljMSAY PRECAST LEVEL SPREADER DETAILS SW2- C N.T.S. 4„ 42"