HomeMy WebLinkAboutWQ0004059_Monitoring - 10-2016_20161219NON DISCHARGE APPLICATION REPORT r HIGH RATE INFILTRATION SITE(S) THERE ARE THREE SITES PER PAGE. USE ADDITIONAL PAGES AS NEEDED. PERMIT NUMBER WQO 004059 COUNTY: FACILITY NAME: Atlantic Station CLASS: III MONTH: Formulas: nnil,. no.iinn rnollnnc/cnnorc fnni\-Vnlnmc 4nnlinri/n�llnnc\lCifc Ar /cn . f..A Page 2 of 2 Carteret OCT YEAR 2016 OPERATOR IN RESPONSIBLE CHARGE (ORC ORC Certification Number: Mail ORIGINAL and TWO COPIES to: ATTN: Non -Discharge Compliance Unit DENR Division of Water Quality 1617 Mail Service Center RALEIGH, NC 27699-1617 Joe Lawrence GRADE: III PHONE: (252) 393-8720 CHECK BOX IF ORC HAS CHANGED x 6§16NATURRE OF OPERATOR IN RESPONSIBLE CHARGE) BY THIS SIGNATURE, I CERTIFY THAT THIS REPORT IS ACCURATE AND COMPLETE TO THE BEST OF MY KNOWLEDGE. DENR FORM NDAR-2(5/2003) v V SITE NUMBER Zone 1 SITE NUMBER Zone 2 SITE NUMBER SITE AREA (sq. ft.): 7,850 SITE AREA (sq. ft.): 7,850 SITE AREA (sq. ft.): WEATHER CONDTIONS PERMITTED RATE (gpd/sp.ft.): 10 PERMITTED RATE (gpd/sp.ft.): 10 PERMITTED RATE (gpd/sp.ft.): D TCode E Weather Temp. Precip ` (•F) talion Volume Applied Time Irrigated Daily Loading Volume Volume Applied Time Irrigated Daily Loading Applied Time Irrigated Daily Loading inches gallons minutes gallons/sq. ft. gallons minutes gallons/sq. ft. gallons minutes gallons/sq. ft. 1 120989 103 15.4126115 10102 86 1.28687898 2 21534 185 2.74318471 13365 132 1.70254777 3 13469 117 1.71579618 10131 88 1.29057325 41 1 11587 100 1.476050961 10313 89 1.31375796 5 8946 770 1.13961783 6854 59 0.87312102 6 9927 80 1.26458599 7073 57 0.90101911 7 12195 101 1.55350318 10505 87 1.33821656 8 7445 63 0.94840764 6854 58 0.87312102 9 11296 102 1.43898089 8305 75 1.05796178 10 800 0 0.10191083 0 0 0 11 11435 95 1.4566879 8065 67 1.02738854 12 9414 83 1.19923567 7486 66 0.95363057 13 10897 97 1.38815287 7303 65 0.93031847 14 11843 97 1.50866242 8058 66 1.02649682 15 6611 60 0.84216561 5289 48 0.67375796 16 11111 95 1.41541401 8889 76 1.13235669 17 12655 109 1.61210191 11145 96 1.41974522 18 10207 83 1.30025478 7993 65 1.01821656 19 11234 98 1.4310828 7566 66 0.96382166 20 8831 72 1.12496815 6869 56 0.87503185 21 9726 88 1.23898089 7074 64 0.9011465 22 12378 108 1.57681529 11921 104 1.51859873 23 11039 98 1.40624204 8561 76 1.09057325 24 10524 95 1.34063694 7976 72 1.01605096 25 10581 93 1.34789809 8419 74 1.07248408 26 5751 47 0.73261146 4649 38 0.5922293 27 11435 101 1.4566879 8265 73 1.05286624 28 5606 47 0.71414013 4294 36 0.54700637 29 11889 105 1.51452229 9511 84 1.21159236 30 10678 93 1.36025478 7922 69 1.00917197 311 1 1 1 14583 130 1.85770701 112171 100 1.4289172 Monthly Loading (gallons/sq.ft.)55.6198726 32.0985987 Year -To -Date Loading (gallons/sq.ft.) 506.73 302.38 ` Weather Codes: S - sunnv. PC - Dartly cloudv. Cl - cloudv. R - rain. Sri - snow. SI - sleet OPERATOR IN RESPONSIBLE CHARGE (ORC ORC Certification Number: Mail ORIGINAL and TWO COPIES to: ATTN: Non -Discharge Compliance Unit DENR Division of Water Quality 1617 Mail Service Center RALEIGH, NC 27699-1617 Joe Lawrence GRADE: III PHONE: (252) 393-8720 CHECK BOX IF ORC HAS CHANGED x 6§16NATURRE OF OPERATOR IN RESPONSIBLE CHARGE) BY THIS SIGNATURE, I CERTIFY THAT THIS REPORT IS ACCURATE AND COMPLETE TO THE BEST OF MY KNOWLEDGE. DENR FORM NDAR-2(5/2003) NON -DISCHARGE APPLICATION REPORT HIGH RATE INFILTRATION SITE(S) FACILITY STATUS: the following permit requirements: (Note: If a requirement does not apply to your facility put "Win the compliant box. __ ..._. Compliant (Y,N) 1. The application rate(s).did riot exceed the limit(s) specified in the permit. 2. The site was kept free of vegetation and raked at intervals specified in the permit. 3. The Automatically Activated Standby power source is on site and operational.' - If the facility is non-compliant, please explain in the space below the reason(s) the facility was not in compliance with its permit. Provide in your explanation the date(s) of the noncompliance and describe the corrective action(s) taken. Attach additional sheets if necessary. I"certify, under penalty of law, that this document and all attachments were prepared under -my direction or" __ supervision in accordance with a system designed to assure that qualified personnel properly gathered -and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." 01g,_naturvof Permittee * Date Sugarloaf Utilities, Inc. . Centre Group Permittee - Please print or type 514 Daniels Street, Suite 414 Raleigh, N(C 27605-1317 Permittee Address Joe Lawrence (Name of Signing Official -Please print or type) Operator Responsible in Charge (Position or Title) 252-393-8720 12/31 /2017 -(Phone Number)- (Permit Exp. Date) ' If signed by other than the permittee, delegation of signatory authority must be on file with the state per 15A NCAC 213.0506 (b) (2) (D). DENR FORM NDAAR-2(5/2003)