Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0034367_Monitoring - 10-2016_20161130 (2)
FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page of Permit No.: WQ0034367 Facility Name: Northwest Regional Water Reclamation Facility county: Onslow Month: October Year: 2016 PPI: 001 Flow Measuring Point: ❑ lnfluent E Effluent ❑ No Flow generated Parameter Monitoring Point: ❑ Influent 0 Effluent ❑ Groundwater Lowering ❑ Surface Water Parameter Code -► 50050 00310 00940 50060 31616 00610 00625 00620 00600 00400 00665 70300 00530 00076 0 a °' y 'C E r O H V W C WO �+ LL Ln D m d 9 C t V @ m C p '� .dt W U E O IL O U 0 C O E Q _ c t GI 00 Cn ~ =' Y Z df - Z c ( cm H& z = O. 2 L H N 0I a. y y D (- An U) p 0) 'O N t6 C O F NU) O 7 H 24 -hr hrs GPD mg/L mg/L mg/L #/100 mL mg/L mg/L mg/L mg/L su mg/L mg/L mg/L NTU 1 07:30 1.5 248,839 0.7 2 07:15 2 259,709 0.64 3 08:00 6.25 214,677 2.2 1.77 <1 <0.2 <1 26.9 26.9 6.86 1.72 11 0.73 4 08:00 5.5 212,235 2.7 4.4 <1 <0.2 3.94 28.6 32.5 7.03 2.99 12.3 0.85 5 07:30 5 648,163 2.4 1 1.68 <1 <0.2 1 <1 28.8 28.8 6.87 1.45 1 3.3 0.82 6 08:15 2.25 404,372 1.53 7.26 0.85 71 08:00 3.75 408,586 1.67 6.97 0.96 8 09:00 8 821,833 1.01 9 00:00 13 1,238,609 1 10 08:00 6.25 457,021 <2 0.41 1 <0.2 <1 19.2 19.2 6.68 1.58 15.6 1.05 11 08:00 6.25 330,571 <2 1 0.19 21.1 <0.2 <1 21 21 6.31 1.54 14.4 0.89 12 08:00 5.25 265,985 5.9 1.54 <1 <0.2 1.31 16.2 17.5 6.88 1.93 9 0.93 131 08:15 3.5 319,452 1.51 6.76 0.98 14 08:00 0.75 314,949 1.89 7.14 1.02 15 07:00 2.5 318,181 0.91 16 07:15 6 308,885 0.83 17 08:00 9 301,792 <2 1 8.8 <1 <0.2 <1 18.4 18.4 7.44 1.81 <2.5 0.77 18 07:45 9.75 310,253 5.7 0.33 <1 <0.2 <1 16.9 16.9 6.9 1.95 7.9 0.73 191 08:00 5.15 729,109 <2 0.38 <1 <0.2 1.6 16.3 17.9 7.56 1.69 5.4 0.68 !; 20 08:00 6.5 430,815 0.4 7.5 0.61 Lj a 21 07:30 5.5 269,853 1.13 7.19 0.6 22 08:15 1 272,822 0.62 o 23 07:15 1 256,621 1 0.62 - © += ca 24 08:15 6 299,844 <2 0.1 <1 <0.2 <1 15.6 15.6 7.07 1.96 2.9 0.63 e+� °da6C 251 08:00 2.5 254,872 6 0.11 <1 0.73 <1 17.4 17.4 6.95 1.95 4.1 0.65 26 0 207,153 4.2 0.14 <1 0.39 <1 16.1 16.1 6.59 2.15 4 0.66 27 08:00 5 445,838 1.33 7.24 0.67 28 08:00 5 72,325 1.64 7.24 0.69 p 29 07:30 1.25 555,187 0.7 1 30 07:45 1.75 79,338 0.71 31 08:00 6.45 438,785 3.6 0.03 <1 <0.2 <1 20.6 20.6 6.77 1.88 2.9 0.73 Average: 377,312 2.52 1.48 1.26 0.09 0.53 20.15 20.68 1.89 7.14 0.78 Daily Maximum: 1,238,609 6.00 8.80 21.10 0.73 3.94 28.80 32.50 7.56 2.99 15.60 1.05 Daily Minimum: 72,325 2.00 0.03 1.00 0.20 1 1.00 15.60 15.60 1 6.31 1.45 1 2.50 0.60 Sampling Type: Recorder Composite Composite I Grab Grab Composite Composite Composite Composite Grab Composite Composite Composite Recorder Monthly Avg. Limit: 1,272,973 10 14 4 10 7 3 5 Daily Limit: 15 25 6 6.0-9.0 10 10 Sample Frequency: Continuous 3 x Week 3 x Year 1 5 x Week 3 x Week 3 x Week 3 x Week 3 x Week 3 x Week 5 x Week 3 x Week 3 x Year 3 x Week lContinuousl FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page Z of Permit No.: W00034367 Facility Name: Northwest Regional Water Reclamation Facility County: Onslow Month: October Year: 2016 PPI: 002 Flow Measuring Point: ❑ Influent E Effluent ❑ No Flow generated Parameter Monitoring Point: ❑ Influent ❑ Effluent El Groundwater Lowering ❑ Surface Water Parameter Code 0 50050 00310 00680 00940 31616 00300 00610 00625 00620 00600 00400 00665 70300 `0 m E U F- Q O O O aO OU ?.' 2 d LL OU prn N x N O mcoe o E o O Mod c H Z L° ZF c O Z Q O Nc tG•y O a > OM v0 yO 24 -hr hrs GPD mg/L mg/L mg/L #/100 mL mg/L I mg/L mg/L mg/L I mg/L su mg/L mg1L 1 07:30 1.5 6,357 2 07:15 2 3,003 3 08:00 6.25 1,411 4 08:00 5.5 1,427 <2 435.2 0.99 <0.2 <1 <0.25 <1 5.91 0.74 5 07:30 5 1,387 61 08:15 2.25. 1,508 7 08:00 3.75 1,398 8 09:00 8 35,926 9 00:00 13 0 10 08:00 6.25 0 11 08:00 6.25 312,941 121 08:00 5.25 167,150 13 08:15 3.5 82,168 14 08:00 0.75 43,803 15 07:00 2.5 28,347 16 07:15 6 17,433 17 08:00 9 9,888 181 07:45 9.75 7,642 <2 <1 3.7 <0.2 <1 0.29 0.31 7.04 0.09 19 08:00 5.15 9,027 20 08:00 6.5 10,408 21 07:30 5.5 8,905 22 08:15 1 5,282 23 07:15 1 2,374 241 08:15 6 763 25 08:00 2.5 833 26 0 864 27 08:00 5 797 28 08:00 1 5 923 29 07:30 1.25 1,006 301 07:45 1.75 784 31F08:00 6.75 886 Average: 24,666 0.00 20.86 2.35 0.00 0.00 0.15 0.16 0.42 Daily Maximum: 312,941 2.00 435.20 3.70 0.20 1.00 0.29 1 1.00 7.04 0.74 Daily Minimum: 0 2.00 1.00 0.99 0.20 1.00 0.25 0.31 5.91 0.09 Sampling Type: Recorder Grab Grab Grab Grab Grab Grab Grab Grab Grab Grab Grab Grab Monthly Avg. Limit: 250 1.5 10 500 Daily Limit: 482,632 6.5-8.5 Sample Frequency:1 Continuous 2 x Month 3 x Year 3 x Year 2 x Month 2 x Month 2 x Month 2 x Month 2 x Month 2 x Month 2 x Month 2 x Month 3 x Year FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page 7 of Permit No.: •00 -367 Facility Name: Northwest Regional - - • October I M. Flow Measuring Point: 0 Influent El Effluent 0 No flow generated Parameter Monitoring Point: 0 influent (:1 Effluent El Groundwater Lowedng 121 Surface -Water mom mI : � f ® ' ' ®®-®-®-®-®-®-®-�- FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page " 1 of Permit No.: WQ0034367 Facility Name: Northwest Regional Water Reclamation Facility County: onslow Month: October Flow Measuring Point: 0 Influent 0 Effluent El No flow generated B;FTF =0 7VI M-ir-limil; M., e L c v • o o ®KIM701A® ER �■ Monthly Avg- Limit- FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page (of & Permit No.: WQ0034367 Facility Name: Northwest. Regional Water Raclarnation Facility County: Onslow Month: October Flow Measuring -. ■ influent ■ Effluent v ■Influent El Effluent ■ Groundwater Lowering El Surface Water Avg- Limit. DailyMonthly -®--®- FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page IR of U Sampling Person(s) Certified Laboratories Name: Mark Young Name: ONWASA Laboratory Cert. # 539 Name: Johnathon Witte, Josh Meadows, Jon Welty Name: Envirochem Cert. # 94 Does all monitoring data and sampling frequencies meet the requirements in Attachment A of your permit? ❑ Compliant 21 Non -Compliant If the facility is non-compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective action(s) taken. Attach additional sheets if necessary. plant exceeded the permitted limits for TSS, NO3, and Total N. Plant staff has been working with Evoqua and Design Engineers on specific adjustments to the SBR's to restore the plant's ability to denitr have also been working with and reporting to Tom Tharrington at the Wilmington Regional office on the exceedances and the efforts to correct any violations. NO3 and Total N exceedance is for Monthly -age, the plant does not have a maximum daily limit. TSS exceedance occured on Oct. 3, 4, 10, and 11th. Operator in Responsible Charge (ORC) Certification Permittee Certification ORC: Mark Young Permittee: Onslow Water and Sewer Authority Certification No.: 1001105 Signing Official: Eddie Caron Grade: 4 Phone Number: 910-937-7570 Signing Official's Title: Planning and Utilities Superintendent Has the ORC changed since the previous NDMR? ❑ Yes p No Phone Number: 910 937-7523 Permit Expiration: 12/31/2016 nature Date Signat a Date By this sig I certify that this report is accumate and complete to the best of my knowledge. I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617