HomeMy WebLinkAbout20161043 Ver 1_B5928 Permit Drawings_20161028�
�
See Sheet 9 A For Index of Sheets
CLEARING ON THIS PROJECT SHALL BE PERFORMED TO
LIMITS ESTABLISHED BY METHOD III.
GRAPHIC SCALES DESIGN DATA
ADT 2012 = 1100
50 25 0 50 100 ADT =
PLANS K = %
D = %
50 25 0 50 100 T= 6 %*
V - 60 MPH
PROFILE (HORIZONTAL) * TTST - DUAL
�0 5 0 �0 2o FUNC CLASS =
MINOR COLLECTOR
PRc�FILE NERTICAu SUBREGIONAL TIER
i
�
;
i
����� �ll �����J� `�/���JI A���
�������� �� ��������
RA11lDOLPH C4 U11lTY
LOCATION: BRIDGE 1V0. 750175 ON SR 2614 (GRA11lTVILLE LANE)
OVER MILL CREEK
TYPE OF WORK GRADI11lG, DRAI11lAGE, PAVING AND BOX CULVERT
AT6 9TAT6 PROJBCT RBP6R8NC6 NO.
��� B-5928
PROl.N0. .A.PROI.NO.
46371.1.1
WETLAND AND SURFACE WATER IMPACTS PERMIT
PROJECT LENGTH
LENGTH ROADWAY PROJECT B-5928
LENGTH STRUCTURE PROJECT B-5928
TOTAL LENGTH OF PROJECT B-5928
I'LANJ YKtiYAKtiU UY: ['LANJ YKtiYAKtiU FVK:
C ENGINEERING DIVISION OF HIGHWAYS
� DIVISION 8
ilY�i(;L[:\'llfl}'��I.ItI).R:\I.CIGII„\("Yl;ll 902 N Saadhi!(s Blvd
"I'I�:LI:`�I'J.itlHtiLY-I I�.-1.\ 41'J.]rits.til�lY Aberdeen, NC 283/S
= 0.128 mi �����.���r.tir,,��,��x,
20I2 STANDARD SPECIFICATIONS
= 0.010 mi
RIGHT OF WAY DATE: BRIAN A. WILES. PE
JULY 15, 2016 PROJECT ENG7NEER
= 0.138 mi
LETTING DATE:
DECEMBER 2016 TIM WELCH, PE
NCDOT CONTACT
DIV 8 BWDGE PROGRAM MANAGER
HYDRAULICS ENGINEER
ROADWAY DESIGN
ENGINEER
P.E.
�
DPPCRlPT
P.E.
0
-L- POC Sta. 12+45.00 �
BEGIN CONSTRUCTION
DETAIL B
TOE PROSECTION
�No�fo cale�
�� u
tiStcE� s�ove
GaoUNo d F
d= 2.OFt. c[ore�ae
Type of Liner= CL B Rip-Rap
FROM STA.14+00 TO STA. 15+70 -L- LT
FROM STA.17+00 TO STA.17+00 TO 17-50 -L- LT
Pl $�0 /2+04.6/
� _ l0' 26' 55.2' !LT!
D = 3' 3d 00.0'
L = 29853'
T = /49.68'
R = 1b37A2'
��i= _____ \
FIELD �� �
�
DARRELL 6 SNEILA WRIGNT
OB 2M� PC 50i
PB �9 PG �
50' 0' 50'
GRAPHIC SCALE
P/ S�o i7+69.56
0 = 0'37'345'lLT1
D = l' 00' OOA'
L = 62.63'
T = 3/3l'
R = 572958'
mIW �
DETAIL A
LATERAL Ba SE DITCH
I no� s�am�
No� ,ol b
Gr und :) p �.,��.
d
�DENOTES IMPACTS W ceorexme e nUn. D- 2.oF�.
SURFACE WATER
Max. d - 1.OF1.
•WFen 8 is : 60' B- 3.OFt.
Type of Liner= CL B Ri�rRop 6= 3.OF.
�DENOTES TEMPORARY
IMPACTS IN SURFACE WATER FROM STA.15+25 TO STA. 16+45 -L- RT
C PROJECT REFERENCE NO. SHEET NO.
ENGINEERING R-5928 4
_ RNJ SHEET NO.
ROADWAY DESIGN HYDRAULICS
3ZZO GLEN ROYAL RD. RALEIGH, NC 2%617 ENGINEER ENGINEER
TEI_E 919.788.0224 FAX 919.788.0232
NC LICENSE xp.p189
MI ENGINEERING INC�Ivg]�]LE ]E PL.�NS
C�1 DO NOT USF, FOR W ACQUISiTION
1011 SCHAUB DRIVE, SUITE 100
RALEIGH, NC 27606
(9'I9)851-6606
FIRM PE NUMBER : P-0671
/ � _ c�i
-L- POT Sta. 19 + 75.00
IS BRK p � i GAR4GE
a `
�
l � �� � �
�W �
� ia�
i�i
�a �
I�I
� .
�
n
CO
FOR PROFILE, SEE SHEET 5
0
-L- POC Sta. 12+45.00 �
BEGIN CONSTRUCTION
� �
�� ��
FIELD
DETAIL B
TOE PROSECTION
�No�fo cale�
�� u
tiStcE� s�ove
GaoUNo d F
d= 2.OFt. c[ore�ae
Type of Liner= CL B Rip-Rap
FROM STA.14+00 TO STA. 15+70 -L- LT
FROM STA.17+00 TO STA.17+00 TO 17-50 -L- LT
Pl $�0 /2+04.6/
� _ l0' 26' 55.2' !LT!
D = 3' 3d 00.0'
L = 29853'
T = /49.68'
R = 1b37A2'
�
DARRELL 6 SNEILA WRIGNT
OB 2M� PC 50i
PB �9 PG �
50' 0' 50'
GRAPHIC SCALE
P/ S�o i7+69.56
0 = 0'37'345'lLT1
D = l' 00' OOA'
L = 62.63'
T = 3/3l'
R = 572958'
� �DENOTES IMPACTS W ceorexme� nUn. D- 2.oF�.
SURFACE WATER
Max. d - 1.OF1.
•WFen 8 is : 60' B- 3.OFt.
Type of Liner= CL B Ri�rRop 6= 3.OF.
�DENOTES TEMPORARY
IMPACTS IN SURFACE WATER FROM STA.15+25 TO STA. 16+45 -L- RT
C PROJECT REFERENCE NO. SHEET NO.
ENGINEERING R-5928 4
_ RNJ SHEET NO.
ROADWAY DESIGN HYDRAULICS
3ZZO GLEN ROYAL RD. RALEIGH, NC 2%617 ENGINEER ENGINEER
TEI_E 919.788.0224 FAX 919.788.0232
NC LICENSE xp.p189
MI ENGINEERING INC�Ivg]�]LE ]E PL.�NS
C�1 DO NOT USF, FOR W ACQUISiTION
1011 SCHAUB DRIVE, SUITE 100
RALEIGH, NC 27606
(9'I9)851-6606
FIRM PE NUMBER : P-0671
/ � _ c�i
-L- POT Sta. 19 + 75.00
IS BRK p � i GAR4GE
a `
�
l � �� � �
�W �
� ia�
i�i
�a �
I�I
� .
� _.
� � . ��.�� �:.� �
��—
n
CO
FOR PROFILE, SEE SHEET 5
� ENGINEERING PROJECT REFERENCE NO. SHEET NO.
L, � B-5928 5
_ ROADWAY DESIGN HYDRAULICS
ENGINEER ENGINEER
3220 CLEN ROYAL RD. RALE[GH, NC 27617
TELE 919.788.0224 FAX 919.758.0232
NC LICENSE �P-OlS9
BM l ELEV = 54023'
N 7/2,366 E /,795.460
-L- STA /2+75 74'LEFT
RR SP/KE �N BASE OF H-FRAME PP
L- TA l +45
L - A +75
L = 525
� � P/ _ /6 Oi0
V= 0'
K = 8
/
� f'� �
- -- -- -- T- -
Y� I Yr (+ 2 �
I I -
I I 6�
f-0 % � � • �� .
o siu nr
(032E� 0165.8 ' �
ti
� 1 11 1 1 1 1 1 W' 1 1 1 20 1
� �� m
� ,
�
� � �� J N
� m V�' M �
Q
w�,� J � � ) J
�»
�`� "Q � � W FOR PLAN, SEE SHEET 4
4.,�, iu �
��,
��
���
��
���
�
�� 10 11 12 13 14 15 16 17 18 19 20 21
530
520
GL STA 15 + 73 -L-
3@12'X14' RCBC, BURIED 1.0'
W/4.0' SILLS IN EASTERN MOST BARREL
& 1.0' SILLS IN REMAINING BARRELS
SKEW = 45
GP ELEV = 524.34'
TB LT
(LOOKING DiS)
510—�`�--�—�_--���-
�r�r�.�,�c�.���-,�,� � .�c��
PROP. C/L �
5OO EXISTING STREAMBED ELEV-504.00'
S = o. oo��o
2 00' 150' 100' 50' 0
�������
TB RT
(LOOKING DiS)
� � � -�.� _- ._ - - -
�� �' � � -
�' NWSEL=505.84'
� (0322/2016)
�---
z�,����,�c�,��,��.�
50'
100' 150' 2 00'
1�T����
DIVISION OF HIGHWAYS
RANDOLPH COUNTY
WBS NO.: �6371.1.1 (B-5928)
REPLACE BRIDGE N0.175
OVER MILL CREEK
ON SR261� (GRANTVILLE RD)
SHEET OF xx � xx./' xx
520
CL II RIP RAP
510 �'
NG.
500
PROPOSED
CL II RIP RAP
4.0' SILL J � 1.0' SILL
CULVERT INLET
TYPICAL CHANNEL SECTION
(LT TO RT LOOKING DOWNSTREAM)
5 0' 0
50'
-�:Zilli�'1���
520
- CL II RIP RAP/ �
� �
�-/
NG. J
CL II RIP RAP
4.0' SILL � 1.0' SILL
CULVERT OUTLET
TYPICAL CHANNEL SECTION
(LT TO RT LOOKING DOWNSTREAM)
������� ������ ������
50'
0 50'
510
I�T����
DIVISION OF HIGHWAYS
RANDOLPH COUNTY
WBS NO.: %6371.1.1 (B-5928)
REPLACE BRIDGE N0.175
OVER MILL CREEK
ON SR 261� <GRANTVILLE RD)
� ��
SHEET OF :x ,/� xx f :x
WETLAND PERMIT IMPACT SUMMARY
Hand Existing Existing
Permanent Temp. Excavation Mechanized Clearing Permanent Temp. Channel Channel Natural
Site Station Structure Fillln Fillln in Clearing in SW SW Impacts Impacts Stream
No. (From/To) Size / Type Wetlands Wetlands Wetlands in Wetlands Wetlands impacts impacts Permanent Temp. Design
ac) (ac) (ac) (ac) (ac) (ac) (ac) (ft) ft) (ft)
1 15+73 -L- 3 12'x14' RCBC 0.08 0.01 83 30
1 15+73 -L- Lt Bank Stabilization 50
1 15+73 -L- Lt Bank Stabilization 48
TOTALS*: 0.08 0.01 181 30 0
*Rounded totals are sum of actual impacts
NOTES:
2073 70 24
1 li�;tl�v 3�' North Carolina Department of Transportation �` �
6t01111bv2itf T Highway Stormwater Program
�.'I
STORMWATER MANAGEMENT PLAN --
(Version 2.04; Released November 2015) FOR NCDOT PROJECTS
WBS Element: 46371.1.1 TIP No.: B-5928 County ies): Randolph Page 1 of 2
General Project Information
WBS Element: 46371.1.1 TIP Number: B-5928 Pro'ect T pe: Brid e Replacement Date: 4/14/2016
NCDOT Contact: Art C. King Contractor I Designer. Karen Hefner, PE
Address: g02 N Sandhills Blvd. Address: 1011 Schaub Drive, Suite 100
Aberdeen, 28315 Raleigh, NC 27606
Phone: 910-944-2344 P hone: 919-851-6606
Email: ackin ncdot. ov Email: khefner mi-en ineers.com
City/Town: Randolph County County(ies): Randolph
River Basin s: Cape Fear CAMA County? No
Wetlands within Project Limits? No
Pro'ect Descri tion
Pro'ect Length lin. miles or feet : 0.138 mi. Surroundin Land Use: Rural
Pro osed Pro'ect Existin Site
Pro'ect Built-Upon Area ac. 0.5 ac. 0.4 ac.
Typical Cross Section Description: 2 lane undivided highway with 11' lanes crown. 2 lane undivided highway with 10' lanes crown.
Annual Avg Daily Traffic (vehlhrlday): Desi n/Future: Year: Existin : 1100 Year: 2012
General Project Narrative: Existing 105' (1@17.5, 1@17.1', 1@28.8', 1@16.5', 1@12.1', and 1@11') bridge timber deck on I-beams with timber caps & piles, timber bulkheads at end bents and interior
(Description of Minimization of Water bents on SR 2614 (Grantville Road) spans Mill Creek. Existing bridge will be replaced while the road is closed (no detour bridge). The replacement structure is a 3@12'x14'
Quality Impacts) Reinforced Concrete Box Culvert. There are no direct discharges into the stream. Roadway drainage is discharged onto the proposed shoulders and fill slopes, there are no other
structures.
Waterbod Information
Surface Water Body (1): Mill Creek NCDWR Stream Index No.: 17-18
NCDWR Surface Water Classification for Water Body Primar Classification: Class C
Su lemental Classification: None
Other Stream Classification: None
Im airments: None
Aquatic T&E Species? No Comments:
NRTR Stream ID: Buffer Rules in Effect: N/A
Pro'ect Includes Brid e Spannin Water Bod ? No Deck Drains Dischar e Over Buffer? No Dissipator Pads Provided in Buffer? N/A
Deck Drains Dischar e Over Water Bod ? No (If yes, provide justification in the General Project Narrative) (If yes, describe in the General Project Narrative; if no, justify in the
(If yes, provide justification in the General Project Narrative) General Project Narrative)
Hl�h\ti'il1' North Carolina Department of Transportation �
SI(lY[]l4b`dtE'C 1
� -,. � Highway Stormwater Program (��:';/
STORMWATER MANAGEMENT PLAN —
(Version 2.04; Released November 2015) FOR NCDOT PROJECTS
WBS Element: 46371.1.1 TIP No.: B-5928 County(ies): Randolph Page 2 of 2
Bridge to Culvert Avoidance and Minimization
Proposed Structure Summa
Sheet No. & Station Sheet No.: 4 Station: 15+73 -L- Number of Barrels: 3
Drainage Area (ac or sq mi : 9.1 sqmi Barrel Width/Diameter (ft : 12
Surface Water Bod : 1 Mill Creek Barrel Hei ht (ft : 14
Culvert T e: Reinforced Concrete Box Culvert Culvert Len th (ft 82
Avoidance and Minimization Efforts: Culvert has been designed to match existing stream channel as close as practicable and provides floodplain bench to avoid overwidening of
(Bridge to Culvert) stream. Culvert will be buried 1 ft and 1' high sills will be used at the inlet and outlet of the low flow culvert barrels to retain native stream bed
material. High flow barrel will have sills at floodplain bench elevation and will be backfilled with native material and provide animal passage.
Culvert has been made taller to help minimize culvert length.
Stream Slope Fish and/or Aquatic Life Passa e
Existing Average Stream Slope (%): 0.30 °/o Existing Low Flow Channel Dimensions 20ft to 24ft.
Proposed Culvert Slope %: 0.00 % in the Stream:
Culvert Burial
Proposed Culvert Burial Depth ft : 1.Oft
Existing Streambed Material: Sand, Cobbles, Gravel Proposed Low Flow Dimensions 24ft
Through the Culvert:
Proposed Sills/Baffles: 4.0' high sill in Eastern most barrel and 1.0' high sill in
the remaining 2 barrels. Existing Low Flow Velocities in the
Stream ft/s : 1.49ft/s
Proposed Low Flow Velocities Through
the Culvert ft/s : 1.5ft/s
Alternating Low Flow Sills/Baffles: N/A
Culvert/Stream Ali nment
Stream Patterns Upstream and Proposed culvert fits existing stream alignment up and downstream and will not require stream realignment. Culvert is located in a straight reach
Downstream of the Culvert that Could of the stream. Downstream channel has straight channel alignment.
Affect Fish Passage and Bank Stability:
Bed Forms Impacted by Culvert (riffles, Glide
pools, glides, etc.):
Low Flow Floodplain Bench Required? Yes
(provide justification)
Sharp Bends at Inlet/Outlet? No
(describe culvert alignment with stream)
Stream Realignment Necessary? (provide No
justification)
Bank Stabilization: Class I Rip Rap on banks only up and downstream.
Outlet Velocities
Natural Stream Channel 2-yr Velocity ft/s): 4.7 Natural Stream Channel 10-yr Velocity (ft/s): 6.1
Proposed Culvert 2-yr Outlet Velocity (ft/s): 5 Proposed Culvert 10-yr Outlet Velocity (ft/s): 6.8
Roadway Geometric Considerations
Evaluate/Describe Roadway Geometric Constraints:
High powered transmission lines cross just west of the beginning of bridge and will pose a safety hazard for construction of bridge. Use of crane to set bridge girders will be safety hazard. To
relocate lines would be very expensive and take a significant amount of time.