Loading...
HomeMy WebLinkAbout20160785 Ver 1_More Info Received_20161018 fes . BioD-Matl 90 Semi-Permanent Woven Brown Bristle Coir Mat ' Sri Lanka patent # 11159 Completely Wildlife Safe! The Highest Quality Woven Coir Mat on the Market! Description The BioD-Mat' 90 blanket is woven from machine twisted bristle coir twines, the best quality coir fiber. This 100% biodegradable, strong and durable blanket provide higher erosion resis- tance while supporting growth and development of vegetation. These semi-permanent mats have functional field longevity of 4-6 years. If the vegetation fails to establish,the open weave in the mat allows seeding over the mat. BioD-Mat°90 blankets are manufactured to conform to the following physical properties. Specifications Property Test Method BioD-Mat°90 Weight ASTM D 3776 29 oz/SY (980 g/m2) Wide width tensile strength Wet ASTM D 4595 Machine direction 1776 lbs/ft(26 kN/m) Cross direction 936 lbs/ft (13.7 kN/m) Wide width tensile strength Dry ASTM D 4595 Machine direction 2024 lbs/ft(29.6 kN/m) Cross direction 1160 lbs/ft(17 kN/m) Elongation at failure Wet ASTM D 4595 Machine direction 52% Cross direction 24% Open area Calculated 38% Thickness ASTM D 1777 0.35 inch (9 mm) Recommended shear stress 5 lbs./sq.ft. (240 N/sq.m.) Recommended flow 16 fps (4.9 m/s) Recommend slope >1:1 Minimum twine count per foot MDxCD 39x 18 BioD-Mat® 90 is available in following roll sizes: 3.28ft x 83ft (30SY) = 1m x 25m (25 sq. m) 6.5ft x 166ft (120SY) = 2m x 50m (100 sq. m) 9.8ft x 166ft (180SY) = 3m x 50m (150 sq. m) 13.1ft x 83ft (120SY) = 4m x 25m (100 sq. m) RoLanka 1 800 760 3215 Tel: 770 506 8211 Fax: 770 506 0391 Interwa f Tonal Inc. E-mail: rolanka@rolanka.com Web: www.rolanka.com SBA's 8(a) &SDB and DOT DBE Certified 155 Andrew Drive, Stockbridge,GA 30281 Strickland, Bev From:Thomas Kelley <tkelley@cdcgo.com> Sent:Tuesday, October 18, 2016 1:34 PM To:Price, Zan (George) Cc:William Elliott (William.A.Elliott@usace.army.mil); Leslie, Andrea J Subject:11443 - Hawthorne South Slope Repair - Buncombe County DWR 16-0785 Attachments:spec-mat90.pdf Zan, Based upon our most recent phone conversation, you were agreeable to our revisions for the slope repair with the exception of the use of SC250 vegetated liner. We are proposing to change the use of SC250 and will now proposed to used Rolanka BioD-Mat 90 (see attachment to this email). This matting has a comparable shear stress rating without the potential to harm wildlife. I hope this change will result in approval of our permit request. Sincerely, Thomas Kelley, PE | Office Locations: 168 Patton Avenue, Asheville, NC 28801 52 Walnut Street, Suite 9, Waynesville, NC 28786 Mailing Address: P.O. Box 5432, Asheville, NC 28813 Work Phone: (828) 252-5388 Ext. 121 Fax Number: (828) 252-5365 Email Address: tkelley@cdcgo.com Website: www.cdcgo.com Privileged and Confidential: The information contained in this email message and any attachments is confidential information intended only for the use of individuals or entities named above. If the reader of this message is not the intended recipient you are hereby notified that any dissemination, distribution or copying of this communication is strictly prohibited. If you have received this email in error, please notify us immediately by email at the originating address. 1