Loading...
HomeMy WebLinkAboutWQ0023693_Monitoring - 08-2016_20161019FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT(NDMR) A+^6 e�(Sce eaw. IC) Page_ of_ Permit No.: W00023693 Facility Name: West Brunswick Regional WWTP (Plant) county: Brunswick Month: August Year: 2016 PPI: Flow Measuring Point: Qlnfl ent ❑Emuent ❑no now generated Parameter Monitoring Point: ❑Innuent ❑Emuent ❑Groundwater Lowering ❑surface water Parameter Code . 50050 00400 00310 f,'! 001IM 00530 31616 00076 00620 00600 00665 00940 1 70295 1 71 c in 0 24 -hr hrs GPD su mg/L O mg/L E mglL ao mg/L ® 9/100 mL a NTU = mg/L ° mg/L °ME: ° 0 m3/L v° mg/L °f y> Nv mg/L ;y. . _ 1 07:00 8 3,709,119 7.4 1.08 0.982 2 07:00 8 3,680,748 7.3 1.13 5 <0.50 <2.5 1 1.042 <0.10 4 093 _ 3 07:00 8 3,583,134 7 1 3 0.93 <2.5 <1 1.118 <0.10 4.69 085 4 07:00 6 4,784,079 7.6 0.99 12 0.98 <2.5 <1 1.226 40.10 6.28 0.61 5 07:00 8 4,339,698 7.4 1.255 1.136 6 4,185,050 0.883 7 4,285.795 0.665 6 07:00 8 4,141,751 7.6 0.99 0.873 9 07:00 8 3,974,616 7.4 1.225 5 <0.50 6.1 <1 1.073 <0.10 4.31 1 10 07:00 8 3,871,424 7.1 1.135 3 0.84 42.5 <1 1.046 <0.10 4.15 104 11 07:00 8 .3,720,421 7.7 1.06 3 0.87 <2.5 <1 1.056 <0.10 4.25 166 12 07:00 6 3,605,760 7.5 0.9 1.056 " 13 3,795,851 1.171 t 14 3,689,907 0.953`\C 15 07:00 8 3,655,821 7.5 1.055 0.947 F.. 16 07:00 8 3,482,614 7.4 1.07 5 40.50 <2.5 <i 0.983 <0.10 6.66 084 17 07:00 8 3,377,929 7.3 0.89 4 0.54 42.5 <1 0.896 1.77 8.4 128 18 07:00 8 3,313,644 7.6 0.94 <2 0.78 <2.5 <1 0.979 0.32 5.72 018 19 07:00 7 3,348,063 7.3 0.935 1.025 201 1 3,557,796 1.162 21 3,470,384 1.09 22 07:00 8 3,313,441 7.4 1.01 1.05 23 07:00 8 ,3,252,519 7.3 1.19 4 <0.50 <2.5 <1 1.18 <0.10 1.4 018 24 07:00 8 '1,054,455 7.3 0.97 <2 0.51 <2.5 <1 1.073 40.10 2.95 015 25 07:00 8 2,879,930 7.6 1.06 <2 0.55 <2.5 <1 1.263 <0.10 3.88 017 26 07:00 8 2,704,059 7.4 0.875 0.983 27 2,854,520 1.001 - 28 2,787,016 1.072 29 07:00 8 2,763,182 7 0.89 1.288 30 07:00 8 2,831,285 7.5 1.03 2 <0.50 <2.5 <1 1.274 2.21 6.86 (,.2 31 07:00 8 2,730,905 7.6 1.03 Q <0.50 <2.5 <1 1.215 1.43 8.63 017 Average: 3,507,901 1.03 2.43 0.43 0.44 1.00 1.06 0.41 5.16 066 Daily Maximum: 4,784,079 7.70 1.26 5.00 0.98 6.10 <1.00 1.29 2.21 8.63 166 Daily Minimum: 2,704,059 7.00 0.88 42.00 40.50 <2.50 01.00 0.67 40.10 1.40 0.15 Sampling Type:posite Recorder Grab Grab Composite Composite Composite Grab Recorder Composite Composite Com Grab Grab Monthly Avg. Limit: 10 4 5 14 7 3 Daily Limit: Sample Frequency: 6.0 MGU 6-9 daily 15 1 6 2x ;;;it 10 10 Continous IkL - 3 x Year 3 x Year FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page _ of Sampling Persons) 11 Certified Laboratories Name: Plant OperatorsI Name: Brunswick County Laboratory Name: Name: Environmental Chemist Laboratory Does all monitoring data and sampling frequencies meet the requirements in Attachment A of your permit? [ACompliant ❑Non -Compliant If the facility is non-compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the noncompliance and describe the corrective action(s) taken. Attach additional sheets 9 necessary. Operator in Responsible Charge (ORC) Certification Permittee Certification ORC: Dixon Medlin Permittee: County of Brunswick Certification No.: 988652 Signing Official: Jerry Pierce Grade: 4 Phone Number: 910-755-7921 Signing Officials Title: Director of Utilities Has the ORC changed since the previous NDMR? ❑res ❑� No Phone Number: (910) 253-2657 Permit Expiration: Sept. 30,2017 I -13t(.- L vV_/3-A Signature Date ign ure I Date By this signature, I certify that this report Is accurate and complete to the best of my knowledge. I certity, under penalty of law, tit t this lilomment and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel property gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submMed is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false infornation, including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Quality Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617