HomeMy WebLinkAboutWQ0004910_Monitoring - 09-2016_20161017Environment 1, Inc_— P.O. Box 7085, 114 Oalcmont Dr. Greenville, NC 27858 Page 1 of environment 1 inc.com DISINFECTION Phone (252) 756-6208 a Fax (252) 756-0633 CHLORINE NEUTRALIZED AT COLLECTION Ij CHLORINE CHECK (LAB) CLIENT: 254 Week: 41 UV pH TOWN OF WOODLAND NONE Ll P P P P P P P P P P CONTAINER TYPE, P/G P.O. BOX 297 WOODLAND NC 27897 A A C C C A A C A A CHEMICAL PRESERVATION A -NONE D-NAOH cz E (252) 587-7161 z�° ui z w 'v cn LL, B - HNO3 E - HCL o o cr o ~ `= w Z a.��, � C - H SO F -ZINC ACETATE/NADH z a COLLECTION ¢ ujcc O LL °' o �j w �; w C o aC3 z s G NATE IIOSULFATE SAMPLE LOCATION DATE TIME o o W¢ Effluent ent Q 1 , �' CLA SSIFI CATION: LaE X WASTEWATER (NPDES) DRINKINGWATER DWO/GW i SOLID WASTE SECTION CHAIN OF CUSTODY (SEAL) MAINTAINED DURING SHI MENT/DELIVERY IN SAMPLES COLLECTED BY: (Please Print) SAMPLES RECEIVED IN LAB AT Q °C R QUISHED BY (SIG.) (SAMPLER) PATBTIME �y REC /E Y (SIG.) ATE/TIME COMMENTS: "a A)SAb10 RELINQUISHED BY (SIG.) DATEMME RECEIVED BY (SIG.) ATErTiME RELINQUISHED BY (SIG.) DATE/TIME RECEIVED BY (SIG.) DATErTIME PLEASE READ Instructions for completing this form on the reverse side. Sampler must place a "C"for composite sample or a "G"for - - FORM #5 Grab sample in the blocks above for each parameter requested. N_ 3 13379 SAMPLING INSTRUCTIONS AND FORM COMPLETION FAILURE TO PROPERLY CHILL, CHEMICA.I_,LY PRESERVE, COLLECT IN PROPER BOTTLE 'L'O'PES, MEET REQUIRED HOLDING TIMES, NEUTRALIZE CHLORINE IN CHLORINE SENSITIVE SAMPLES, AND SEAL COOLERS WITH TAPE WILL RESULT IN SAMPLES BEING � EJECTED BY THIS LABORATORY AS PER NORTH CAROLINA REGULATORY CODE. 1) Samples not falling within the required guidelines will need to be re -collected. The client will be contacted and informed of any t_<leviation and asked to collect another set of samples. The client may request the laboratory to proceed with the analyses of the current samples. Any samples analyzed outside of the required guidelines will be "qualified". This means that a note will be included on the sample result and "Chain of Custody" specifying the deviation. The laboratory is also required to send a letter to the State noting the deviations. 2) Sample Temperature. Samples for compliance monitoring must be chilled with wet ice to a temperature of 6C or less. Freezing is not permitted. Samples delivered to the lab shortly after collection may not have had enough time to be chilled below 6C. In this case the temperature at time of collection must be noted in the space provided. The samples will meet the requirements of the regulation if there is a temperature drop from the time of collection until received in the lab. Regardless, all samples should be packed in wet ice using as rnuch ice as will fit in the cooler. 3) Sample Chemical Preservation. Many samples require a chemical preservation such as Sulfuric Acid or Sodium Hydroxide. The laboratory will either provide the preservative in the sample bottle, or in the case of 40 ml. Volatiles Vials, provide a bottle of Acid with detailed descriptions on ]low to collect the sample. Never rinse sample bottles before collecting samples. Any residue or liquid in the bottle is required for proper chemical preservation. The lab must verify proper chemical preservation upon arrival in the lab and will note this information in the spaces provided on the front of this form. 4) Chlorine Neutralization. Some samples require that any Total Chlorine Residual be removed at the time of collection. The lab will provide the proper neutralizing agent in the sample bottle when technically possible. There are some samples (Total Kjeldahl Nitrogen and Ammonia Nitrogen) where this is not possible due to interferences between the required chemical preservation (Acid) and the dechlorinating agent. Therefore, these samples must be de -chlorinated at the time of collection before being placed in our sample bottles. Sodium Thiosulfate is the chemical of choice to neutralize chlorine. It must be added to your sample and then the sample checked for Total Chlorine before the sample is poured in our bottle. Facilities using chlorine for disinfection should have a means of measuring Total Chlorine. Non -chlorinated sample sources will not need to be checked. The person neutralizing the chlorine must put his initials in the "Chlorine Neutralized at Collection" row on the front of this form above the proper parameter. Samples such as Coliforms (which have Thiosulfate in the bottles shipped from the lab) will be checked for proper neutralization upon arrival in the lab. It is also required that you note the "Total Chlorine at Collection" on the front of this form for any sample locations applicable. This value would be before any neutralization is performed. 5) A "C" for Composite Sample or a "O" for Crab Sample should be placed in the box for all requested parameters. Crab temperatures as well as Composite start dates and times can be recorded in the "comments" section. 6) Other information required to he completed by the client are: Collection Date and Collection Time for each sample location Temperature at Time of Collection Printed name of person or persons collecting samples Signature, Date, and Time samples are relinquished Other added sample locations and analyses required Type Of Disinfection Deletion on the form for any samples which are not needed (example: dry upstream location) Any other information felt to be pertinent should be included in the "Cotnments" section CONSIDERATIONS: Coliform and Enterococci samples have a holding time of 6 hours from time ofcollection to time of analysis. Therefore, samples should be collected as late in the day as possible to allow enough time for transportation, checking in at the lab and analysis. BOD, Nitrate, Ortho Phosphorus, Settleable Matter. Turbidity, Color, and MBAS samples have a 48 hour holding time. The lab reserves the right to establish required sample collection and delivery dates in order to meet the required holding times. CAUTION Sample bottles may contain acids or other corrosive and potentially harmful chemicals. Laboratories are required to add these chemicals for certain analyses in order to comply with EPA preservation requirements. Use extreme care when opening and handling the shipping container and bottles. If any chemical should get into your eyes, on your skin or on your clothes, hush liberally with water and seek medical attention. Material Safety Data Sheets (MSDS) are available upon request which specify proper handling and personal protection. vw'nimnbm� Flo hmpumUd TOWN OF WOODLAND P.O. BOX 297 WOODLAND ,NC 27897 ID#: 254 DATE COLLECTED: 09/08/16 DATE REPORTED : 09/21/16 / y REVIEWED BY: 1✓ \ Effluent Analysis Method PARAMETERS Date Analyst Code BOD, mg/l 29 09/08/16 KKM 521OB-01 Fecal Coliform (MF), /100 Mls 370 09/08/16 KNF 9222D-97 Total Suspended Residue, mg/l 28 09/09/16 KDS 2540D-97 Ammonia Nitrogen as N, mg/l 8.60 09/16/16 AKS 350.1 R2-93 Total Kjeldahl Nitrogen as N,mg/l 14.69 09/15/16 AKS 351.2 R2-93 Nitrate -Nitrite as N, mg/l (calc) < 0.04 353.2 R2-93 Nitrate Nitrogen as N, mg/l < 0.04 09/14/16 RAJ 353.2 R2-93 Nitrite Nitrogen as N, mg/l <0.02 09/09/16 MF 353.2 R2-93 Total Phosphorus as P, mg/l 2.23 09/15/16 MF 365.4-74 Calcium, ug/l 16944 09/16/16 LFJ EPA200.7 Magnesium, ug/l 2124 09/16/16 LFJ EPA200.7 Sodium, ug/l 507750 09/19/16 JMN 311113-99 Sodium Adsorption Ratio (calc) 30.8 Total Nitrogen, mg/l (calc) 14.69 ID#: 254 DATE COLLECTED: 09/08/16 DATE REPORTED : 09/21/16 / y REVIEWED BY: 1✓ \