Loading...
HomeMy WebLinkAboutNCS000040 DMR SW (12) URS • _ June 23, 2016 Ms. Jennifer Pappalardo RECEIVED Charlotte Pipe and Foundry JUN 3 0 2016 1335 South Clarkson Street Charlotte,North Carolina 28203 CENTRAL FILES DWR SECTION Re: Stormwater Discharge Monitoring Reports Charlotte Pipe and Foundry 1335 South Clarkson Street Charlotte,North Carolina URS Project No. 38941506 Dear Ms. Pappalardo: URS Corporation — North Carolina (URS) is pleased to submit the attached Stormwater Discharge Monitoring Reports (DMRs) and Qualitative Monitoring Reports (QMRs) to Charlotte Pipe and Foundry for stormwater samples collected on May 20, 2016. The DMRs summarize the laboratory analytical and storm parameters in accordance with storm water discharge permit number `�C!``OR(9340. Please sign the attached documents and mail the original and one additional copy to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh,NC 27699-1617 URS appreciates the opportunity to provide environmental services to Charlotte Pipe and Foundry. If you have any questions or need additional information, please do not hesitate to contact us. Sincerely, URS CORPORATION-NORTH CAROLINA 7/// Christopher M.Rocco Project Manager URS Corporation—North Carolina 6000 Fairview Road Suite 200 Charlotte, North Carolina 28210 (704) 522-0330 Phone (704) 522-0063 Fax STORMWATER DISCHARGE OUTFALL (SDO) ANNUAL SUMMARY DATA MONITORING REPORT (DMR) Calendar Year 2016 Individual NPDES Permit No. * :O 00.040 or Certificate of Coverage (COC) No. NCG This monitoring report summary of the calendar year is due to the DWQ Regional Office no later than March 1st of the following year. Facility Name: CHARLOTTE PIPE AND FOUNDRY County: MECKLENBURG Phone Number: (704) 332-2647 Total no. of SDOs monitored: 1 Outfall No. : SW-004 1/4/8 D - Is this outfall currently in Tier 2 (monitored monthly)? Yes ® No ❑ pg4T Was this outfall ever in Tier 2 (monitored monthly) during the past year? Yes 111 No ® �1 ��� � If this outfall was in Tier 2 last year, why was monthly monitoring discontinued? /0,4 Enough consecutive samples below benchmarks to decrease frequency ❑ Received approval from DWQ to reduce monitoring frequency Other ❑ Was this SDO monitored because of vehicle maintenance activities? Yes ❑ No Parameter, (units) Total Oil and Total ' Total ' Chemical Rainfall, Grease Chromium Kjeldahl Copper Lead Nickel Zinc Phenol Suspended pH ' Oxygen inches (mg/L) (ug/L) Nitrogen (ug/L) (ugIL) (ug/L) (ug/L) : (mg/L) Solids(TSS) (s.u:) Demand, (mg/L) (mg/L) (mg/L) -)S� h_m.ai 4 "4AP"�: ,40,�� �,1OO1 �. <.: 3q6;-;�i .60A et� k Date Sample � r 1N2f=I:i an.'#r. .#., `.�, ,*�s.e^'k �•ti?, x c.4Yr�aty . , .'. fg 5 •; mm/dd/yy � ;, � � i � - ° � � � � f,,� : � ,,'-�,� • - �. .� .,, •a�Aac :`_'�.+a `�:r�*'�s'i°� �,.. � a "� # :-"::b. .a$s �i". 5/20/2016 0.74 5.78 ND 0.59 5.9* 9.0 ND 94.5* ND 43.7 6.9 ND • *= Values for copper and zinc are net deductions from sample analytical results from upgradient outfall SW-003. SW U-264-Generic-25 May2010 Additional Outfall Attachment Outfall No.: SW-006 Is this outfall currently in Tier 2 (monitored monthly)? Yes ❑ No IZ Was this outfall ever in Tier 2 (monitored monthly) during the past year? Yes ❑ No If this outfall was in Tier 2 last year, why was monthly monitoring discontinued? Enough consecutive samples below benchmarks to decrease frequency Received approval from DWQ to reduce monitoring frequency ❑ Other Was this SDO monitored because of vehicle maintenance activities? Yes ❑ No El Parameter, (units) Total Oil and Total - Total Chemical- Rainfall, Grease Chromium Kjeldahl Copper Lead Nickel Zinc Phenol Suspended pH Oxygen inches (mg/L') (ug/L), Nitrogen (ug/L) (ug/L) , (ug/L) OWL) (mg/L) Solids(TSS) (s:u.) Demand (mg/L). (mg/L) (mg/L) Benchmark4 ,PI/A 'x're30. _. x1000 ,20 7 -, 30 200 ":t67.t'! 4,5' 100, 6-9, ::,-±1.20,0 Date Sample1r^�,,1pa ' - R_ W�1kl._� - .. S,a vx� __ -�-sa`' (;`:a-ce�- f r2t�..•.r„x,E n Ki g,s_,-=-�n".`%�'rTi"_tea-+s'"-�?:.'a'__ _433"'471 a, ` :47--;;;;75: �r1 " t O aa r Collected,uk mm/dd/YY � .� , � a= .Aka 5/20/2016 0.74 2.53 ND ND ND* 5.6 ND 44.3* ND 8.1 6.4 ND • * =Values for copper and zinc are net deductions from sample analytical results from upgradient outfall SW-003 SWU-264-Generic-25May2010 "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." ✓t Signature Date 6/28/2016 Mail Annual DMR Summary Reports to: DWQ Regional Office Contact Information: ti,"±----41.p..ii.:.7M_ ' ,...,,; ,..,:.,4s.i,,,,,,.-ig, _.., ,,,,,-.4-fi,_ ,-. . - -:--,- .77:_...) . ,:i.- s - ,4.--'„-- - 4 , 4-7 vv. --,, c: --'„ ,I A ‘. 441-tC , -oi..p t% y l Il 23,i g,. A�. ,Ail r.�,•a�,-(t—J zlzke i 7 L A vi.. _ ' ;B� � `C -'' e7 tiL ' l�n Fon ASHEVILLE REGIONAL OFFICE FAYETTEVILLE REGIONAL OFFICE I MOORESVILLE REGIONAL OFFICE 2090 US Highway 70 225 Green Street 610 East Center Avenue/Suite 301 Swannanoa,NC 28778 Systel Building Suite 714 Mooresville,NC 28115 (828) 296-4500 Fayetteville,NC 28301-5043 (704) 663-1699 (910) 433-3300 RALEIGH REGIONAL OFFICE WASHINGTON REGIONAL OFFICE WILMINGTON REGIONAL OFFICE 3800 Barrett Drive 943 Washington Square Mall 127 Cardinal Drive Extension Raleigh,NC 27609 Washington,NC 27889 Wilmington,NC 28405-2845 (919) 791-4200 (252) 946-6481 (910) 796-7215 WIlNS_T ON-SALEM REGIONAL OFFICE CENTRAL OFFICE 585 Waughtown Street 1617 Mail Service Center ; --, "To oseserve protect Winston-Salem,NC 27107 Raleigh,NC 27699-1617 O and enhance. (336) 771-5000 (919) 807-6300 Alprili Carolinas wafer..." SWU-264-Generic-25May2010