HomeMy WebLinkAboutNCG030212 DMR SW (21) Semi-annual Stormwater Discharge Monitoring Report
for North Carolina Division of Water Quality General Permit No. NCG030000
Date submitted 4/30/2016
CERTIFICATE OF COVERAGE N a r €G030 SAMPLE COLLECTION YEAR_2016
FACILITY NAME Prysmian Cables and Systems USA, LLC SAMPLE PERIOD ❑Jan-June ❑July-Dec
COUNTY Catawba or ® Monthlylalli (month)
PERSON COLLECTING SAMPLES_Rick Miller DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA
LABORATORY Prism Labs Lab Cert.# 402REGE ❑Zero-flow ['Water Supply OSA
Comments on sample collection or analysis: April Tier II Sampling �� � /IOther_NPDES
AUG 2 6 2016 PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 -�
CENTRAL FILES
Part A: Stormwater Benchmarks and Monitoring Results DWR SECTION
® No discharge this period?2
Non-Polar O&G/ Total Toxic
Date Sample 24-hour rainfall pH,
Outfall No. Collected1 amount, Total Suspended Solids Standard units Copper Lead Zinc Total Petroleum Organics
(mo/dd/yr) Inches3 Hydrocarbons
Benchmarks===> - - 100 mg/L or 50 mg/L4 6.0—9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L
SDO-001
SDO_002
SDO-002D
SDO-003A
SDO-005
1 Monthly sampling(instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall.
2 For sampling periods with no discharge at any single outfall,you must still submit this discharge monitoring report with a checkmark here.
3The total precipitation must be recorded using data from an on-site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement.
4 See General Permit,Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies.
5 Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture
electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA
Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor
manufacture use the definition as found in 40 CFR 469.12;for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray
tube manufacture use the definition found in 40 CFR 469.31).
Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012
Page 1 of 3
Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring
may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General
Permit. For those facilities electing to employ the TTO monitoring waiver,the discharger shall sign the following certification statement:
"Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics
(TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwatg „4, ,areas which are exposed to rainfall or
stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the
solvent management plan,included in the Stormwater Pollution Prevention Plan."
Rick Miller
Name(Print name)
HSE Manager
Title(Print title)
ter:4 . 1&'16•Z,"-- 6 .2- /
(Signature) Date)
Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL,<PQL, Non-detect, ND, or other similar non-numerical
format. When results are below the applicable limits,they must be reported in the format, "<XX mg/L",where XX is the numerical value of the detection
limit, reporting limit, etc. in mg/L.
Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text.
Part B: Vehicle Maintenance Area Monitoring Results:only for facilities averaging> 55 gal of new oil per month.
❑ No discharge this period?2
Date Sample 24-hour rainfall
Outfall No. Collected' amount, Non-polar O&G/TPH by
(mo/dd/yr) Inches3 EPA 1664(SGT-HEM) Total Suspended Solids pH
Benchmarks===> - - 15 mg/L 100 mg/L or 50 mg/L* 6.0—9.0 SU
Footnotes from Part A also apply to this Part B
*See General Permit text,Table 5,identifying the especially sensitive receiving water classifications where the more protective benchmark applies.
Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012
Page 2 of 3
Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text.
FOR PART A AND PART B MONITORING RESULTS:
• A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B.
• 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B.
• TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ❑ NO
IF YES,HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO❑ -
REGIONAL OFFICE CONTACT NAME:
Mail an original and one copy of this DMR, including all"No Discharge"reports, within 30 days of receipt of the lab results(or at end of monitoring period
in the case of"No Discharge"reports)to:
Division of Water Quality
Attn: DWQ Central Files
1617 Mail Service Center
Raleigh, North Carolina 27699-1617
YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED:
"I certify, under penalty of law,that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to
assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system,or
those persons directly responsible for gathering the information,the information submitted is,to the best of my knowledge and belief,true,accurate, and complete. I
am aware that there are significant penalties for submitting false information,including the possibility of fines and imprisonment for knowing violations."
,14.A.A.— i'lle.------*------- Ci2pc.
(Signature of Permittee) (Date)
Permit Date:11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012
Page 3 of 3
Prysmian PRYSMIAN
Group - Draka
August 21,2016
CERTIFIED MAIL RECEIVED
RETURN RECEIPT REQUESTED
7014 2120 0004 1838 9574 AUG 2 6 2016
NCDENIR—Division of Water Quality CENTRAL FILES
Attn:Central Files
1617 Mail Service Center DWR SECTION
Raleigh,North Carolina 27699-1617
Subject: General Permit No.NCG030000
Certificate of Coverage l CGO 02',
March 2016,April 2016,Ma 201 , une 016 and July 2015 Tier II Stormwater Sample Results
Prysmian Cables and Systems USA,LLC.
Claremont,North Carolina 28610
I have enclosed two(2)signed Discharge Monitoring Reports(DENR Form SWU-245-10/25/2012 revision)for the March,April,May and July reports
which are"No Discharge"reports.
I have also enclosed two(2)signed Discharge Monitoring Reports(DENR Form SWU-245-10/25/2012 revision)for June 29,2016. Prysmian received
the analytical results on July 22,2016. Accompanying the discharge monitoring reports are copies of:
• laboratory analytical reports
• stormwater data summary with flow calculations
• Site map documenting stormwater outfall locations,drainage areas and runoff factors.
The sample event satisfies analytical monitoring requirements in accordance with Part II,Section B of the General Permit effective 1 November 2012.
Results:June sampling results were all within permit threshold limits on all outfalls.
Prysmian's manufacturing activities do not fall in categones that required Total Toxic Organic(TTO)monitoring No TTO results are submitted.
The stormwater data summary sheet included with the enclosures summarizes flow and analytical results for all storms previously sampled at the
Prysmian Claremont site.
Please contact me if you have questions concerning this submittal.
Very truly yours—
Ve
Rick Miller
Environmental/Safety Manager
828-459-8668
rick miller@prysmiangroup corn
Prysmian Cables and Systems USA,LLC
PO Box 39,2512 Penny Road,Claremont,NC 28610
Tel (828)459-8668 Fax(828)459-8268