Loading...
HomeMy WebLinkAboutNC0024911_Authorization to Construct_20160712Water Resources ENVIRONMENTAL QUALITY PAT MCCRORY coremor DONALD R. VAN DER VAART Secretary S. JAY ZIMMERMAN Director July 12, 2016 Mr. Tom Hartye General Manager Metropolitan Sewerage District of Buncombe County 2028 Riverside Drive Asheville, North Carolina 28804 SUBJECT: Authorization to Construct A to C No. 02491 lA03 Metropolitan Sewerage District of Buncombe County French Broad River WRF Dear Mr. Hartye: A letter of request for an Authorization to Construct was received May 23, 2016, by the Division of Water Resources (Division), and final plans and specifications for the subject project have been reviewed and found to be satisfactory. Authorization is hereby granted for the construction of modifications to the existing 40 MGD French Broad River WRF, with discharge of treated wastewater into the French Broad River in the French Broad River Basin. This authorization results in no increase in design or permitted capacity and is awarded for the construction of the following specific modifications: Installation of new -fine screen system consisting of three (3) 40 MGD automated mechanical screens with VFD, sluicing trough, screens washer/compactors, piping, and controls; installation of new grit system consisting of two (2) 50 MGD:.vartex grit chambers with vacuum pumps, concentrators, water classifiers, piping, and controls; replacement of existing influent pumps screens with two (2) 40 MGD automated mechanical traveling rake screens with conveyor/compactors, piping, and controls; installation of new flow splitter box, piping, and controls; refurbishment of existing structure to new surge pump station including three (3) new 3,472 GPM at 60 ft TDH surge pumps with variable drive, piping, and controls; conversion of two surplus digesters to two (2) 2.1 MG surge tanks, piping, and controls; in conformity with the project plans, specifications, and other supporting data subsequently filed and approved by the Department of Environmental Quality. This Authorization to Construct is issued in accordance with Part I11, Paragraph A of NPDES Permit No. NCO024911 issued effective April 1, 2011, and shall be subject to revocation unless the wastewater treatment facilities are constructed in accordance with the conditions and limitations specified in Permit No. NCO024911. State of North Carolina I Environmental Quality I Water Resources 1617 Mail service Center I Raleigh, North Carolina 27699-1617 Location: 512 N. Salisbury St. Raleigh, North Carolina 27604, Archdale Building 9th Floor Phone: 919 807.6300 /Fax: 919 807 9489 Mr. Tom Hartye, General Manager July 12, 2016 Page 2 of 3 The sludge generated from these treatment facilities must be disposed of in accordance with G.S. 143-215.1 and in a manner approved by the Division. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by the Division, such as the construction of additional or replacement wastewater treatment or disposal facilities. The Asheville Regional Office, telephone number (828) 296 - 4500, shall be notified at least forty-eight (48) hours in advance of operation of the installed facilities so that an on site inspection can be made. Such notification to the regional supervisor shall be made during the normal office hours from 8:00 a.m. until 5:00 p.m. on Monday through Friday, excluding State Holidays. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with the NPDES Permit, this Authorization to Construct and the approved plans and specifications. Mail the Certification to: Division of Water Resources, WQ Permitting Section — NPDES, 1617 Mail Service Center, Raleigh, NC 27699-1617. Upon classification of the facility by the Certification Commission, the Permittee shall employ a certified wastewater treatment plant operator to be in responsible charge (ORC) of the wastewater treatment facilities. The operator must hold a certificate of the type and grade at least equivalent to or greater than the classification assigned to the wastewater treatment facilities by the Certification Commission. The Permittee must also employ a certified back-up operator of the appropriate type and grade to comply with the conditions of T15A:8G.0202. The ORC of the facility must visit each Class I facility at least.weekly and each Class II, III and IV facility at least daily, excluding weekends and holidays, must properly manage the facility, must document daily operation and maintenance of the facility, and must comply with all other conditions of T15A:8G.0202. A copy of the approved plans and specifications shall be maintained on file by the Permittee for the life of the facility. During the construction of the proposed additions/modifications, the permittee shall continue to properly maintain and operate the existing wastewater treatment facilities at all times, and in such a manner, as necessary to comply with the effluent limits specified in the NPDES Permit. You are'reminded that it is mandatory for the project to be constructed in accordance with the North Carolina Sedimentation Pollution Control Act, and when applicable, the North Carolina Dam Safety Act. In addition, the specifications must clearly state what the contractor's responsibilities shall be in complying with these Acts. Prior to entering into any contract(s) for construction, the recipient must have obtained all applicable permits from the State. Mr. Tom Hartye, General Manager July 12, 2016 Page 3 of 3 Failure to abide by the requirements contained in this Authorization to Construct may subject the Permittee to an enforcement action by the Division in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. The issuance of this Authorization to Construct does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. If you have any questions or need additional information, please contact Ron Berry at telephone number (919) 807-6396. Sincerely, S. Jay Zimmerman Director, Division of Water Resources cc: Brian Thorsvold, P.E. HDR Engineering, Inc. of the Carolinas 440 South Church Street Suite 1000 Charlotte, NC 28202 DWR/Asheville Regional Office, Water Quality Programs Central Files .NPDES File Without Engineer's Certificate attached: Buncombe County Health Department I Metropolitan Sewerage District of Buncombe County French Broad River WRF Authorization to Construct No. 024911A03 Issued July 12, 2016 Engineer's Certification I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically/weekly/full time) the construction of the modifications and improvements to the French Broad River Wastewater Reclaim Facility, located in Buncombe County, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the following construction: Installation of new fine screen system consisting of three (3) 40 MGD automated mechanical screens with VFD, sluicing trough, screens washer/compactors, piping, and controls; installation of new grit system consisting of two (2) 50 MGD vortex grit chambers with vacuum pumps, concentrators, water classifiers, piping, and controls; replacement of existing influent pumps screens with two (2) 40, MGD automated mechanical traveling rake screens with conveyor/compactors, piping, and controls; installation of new flow splitter box, piping, and controls; refurbishment of existing structure to new surge pump station including three (3) new 3,472 GPM at 60 ft TDH surge pumps with variable drive, piping, and controls; conversion of two surplus digesters to two (2) 2.1 MG surge tanks, piping, and controls; in conformity with the project plans, specifications, and other supporting data subsequently filed and approved by the Department of Environmental Quality. I certify that the construction of the above referenced project was observed to be built within substantial compliance, intent and in conformity with all applicable regulations and statutes and the project plans, specifications, and other supporting documentation comprising the Authorization to Construct Permit Application package. Signature Registration No. Date \ Mail this Certification to: Attn: Ron Berry Complex Permitting Unit DEQ/DWR/Water Quality Programs 1617 Mail Service Center Raleigh, NC 27699-1617