HomeMy WebLinkAbout20071658 Ver 2_Staff Comments_2008031007-1658 Taft Woods East Subject: 07-1658 Taft Woods East From: Annette Lucas <Annette.Lucas@NCMail.net> Date: Mon, 10 Mar 2008 13:33:36 -0400 To: Amy Chapman <amy.chapman@ncmail.net> CC: Annette Lucas <Annette. Lucas@NCMail. net> Amy, I have reviewed this project and these are some of the best level spreader designs I have seen on the first go-around. The only comments I have are: According to plan sheet 10 of 16, the filter strip downslope of level spreader 6 appears to have greater than 8 percent slope. Please relocate this level spreader to a location with appropriate slopes or provide a properly designed BMP that removes 85 percent of TSS and 30 percent of Total Nitrogen and Total Phosphorous. If you choose to provide a BMP, please submit the appropriate BMP Supplement Form with all required items attached. The plans should be the final construction drawings and these plans are labeled "Preliminary - Not for Construction." That's all, Annette 1 of 1 3/10/2008 1:34 PM