Loading...
HomeMy WebLinkAbout20070776 Ver 1_More Info Letter_20080310OF W A T~~ Michael F. Easley, Governor ~~~ ~G William G. Ross Jr., Secretary UJ 1~...- North Carolina Department of Environment and Natural Resources 7 0 ~ Coleen Sullins, Director Division of Water Quality ,, March 10, 2008 DWQ Project # 07-0776 Haywood County CERTIFIED MAIL: RETURN RECEIPT REQUESTED Waynesville Commons Retail Associates, LLC 1765 Meriman Road Akron, OH 44313 Subject Property: Waynesville Town Center Richland Creek [040305, 5-16-(1), B, TR] REQUEST FOR MORE INFORMATION: STORMWATER MANAGEMENT PLAN Dear Sir or Madam: On October 22,.2007, the Division of Water Quality (DWQ) issued a 401. Water Quality Certification to fill or otherwise impact 52 linear feet of perennial stream in order to construct the above. named project. In order to meet Condition 9 of the 401 Certification for this project, a stormwater management plan, dated February 11, 2008, was received by the DWQ. on February 13, 2008. The DWQ has determined that your stormwater management plan was incomplete as discussed below. Additional Information Requested: 1. For all BMPs: a. An up to date soils report that documents the soil infiltration rates and SHWT levels at each of the four BMP locations. b. Information on the pre-treatment system you are using for the two sand filters. c. Please show the limits of the proposed drainage easements for the BMPs on the plans. d. Please provide a construction sequence that shows that the BMPs will be protected from sediment during construction until the entire drainage area is stabilized. 2. For the proposed sand filters: a. Please provide clean-outs for the underdrain systems. b. Please provide a minimum slope of 0.5% on the underdrain systems. c. For infiltration basin A, it appears that there maybe two inlets entering this basin that do not pass through a flow splitting device. If this is the case, please correct this so that all flows enter the basin via a flow splitting device and a forebay. 401 Oversight/Express Review Permitting Unit 1650 Mail Service Center, Raleigh, North Carolina 27699-1650 2321 Crabtree Boulevard, Suite 250, Raleigh, North Carolina 27604 Phone: 919-733-1786 /FAX 919-733-6893 /Internet: htip_!h?c,enrstate,nc_us~.ncwellands No°e Carolina ~turallr~ An Equal Opportunity/Affirmative Action Employer - 50% Recycled/10% Post Consumer Paper Waynesville Commons Retail Associates, LLC Page 2 of 2 March 10, 2008 3. For the proposed infiltration basins: a. Please provide afour-inch sand layer on the bottom of each infiltration basin. b. On plan sheet 3.6, the bypass structure detail is incorrectly labeled - it also applies to manholes 31 a and 44. The DWQ will require the above additional information to finalize review of the stormwater management plan for the subject property. Please provide the following information so that we may continue to review your project. You are welcome to contact me at 919-715-3425 if you have questions or would like to set up a meeting. Sincerely, j ~~ ~"t~i_ Annette Lucas, Environmental Engineer III 401 Oversight/Express Review Permitting Unit AML/aml cc: Kevin Barnett, DWQ Asheville Regional Office USACE Asheville Regulatory Field Office File Copy Central Files Gary O'Nesti, Cedarwood Development, Inc., 1765 Meriman Road, Akron, OH 44313 Filename: 070776 WaynesvilleTownCenter(Haywood)_S W_Hold.doc