HomeMy WebLinkAbout20160685 Ver 1_401 Application_20160716COURTESY COPY A!�LMG 2'0 1 6' 0 6 8 5 LAND MANAGEMENT GROUP INC Environmental Consultants July 8, 2016 r TO: Mr. John Policarpo U.S. Army Corps of Engineers 69 Darlington Avenue Wilmington, NC 28403 R_9@[RL9W1 JUL 1 2 2016 DEQ -WATER RESOURCES 401 & BUFFER PERMITTING RE: NWP 12 Application; EF Middleton (SR 1105) Water Main Improvements St. James, NC (Brunswick County) Dear John: Enclosed is a NWP 12 application for your review. This application is submitted on behalf of Brunswick County for the installation of a waterline within a maintained NC DOT Right -of -Way along Middleton Blvd and Seafield Drive in St. James, NC. The project is needed to improve water pressure and fire flows within the St. James development. Temporary impacts to 1.11 acres of wetlands are needed to install the line. The impact areas will be returned to preconstruction grade and seeded once the installation is complete. The Pre -Construction Notification form, associated maps, and site plan are enclosed for your review. Please contact me if you have any questions. Thank you for your assistance with this project. Sincerely, Kim Williams Environmental Scientist Encl. Cc: Mr. John Nichols, Brunswick County Mr. Kevin Plemmons, McKim & Creed Mr. Chad Coburn, NC DWR — courtesy copy - Ms. Jennifer Burdette, NC DWR — courtesy copy www.lmgroup.net • info@lmgroup.net • Phone: 910.452.0001 • Fax: 910.452.0060 3805 Wrightsville Avenue, Suite 15 • Wilmington, NC 28403 oJaj�0'�_ \N AT�R�G Office Use Only: Corps action ID no. DWQ project no. Form Version 1 3 Dec 10 2008 Page 1 of 12 PCN Form — Version 1 3 December 10, 2008 Version Pre -Construction Notification (PCN) Form A. Applicant Information 1. Processing 1 a. Type(s) of approval sought from the Corps: ® Section 404 Permit E] Section 10 Permit 1 b Specify Nationwide Permit (NWP) number: 12 or General Permit (GP) number: 1 c Has the NWP or GP number been verified by the Corps? N Yes ❑ No 1 d Type(s) of approval sought from the DWQ (check all that apply). ❑ 401 Water Quality Certification — Regular ❑ Non -404 Jurisdictional General Permit ❑ 401 Water Quality Certification — Express ❑ Riparian Buffer Authorization 1 e. Is this notification solely for the record because written approval is not required? For the record only for DWQ 401 Certification: N Yes ❑ No For the record only for Corps Permit: ❑ Yes N No 1f. Is payment into a mitigation bank or in -lieu fee program proposed for mitigation of impacts? If so, attach the acceptance letter from mitigation bank or in -lieu fee program ❑ Yes N No 1g Is the project located in any of NC's twenty coastal counties. If yes, answer 1h below. N Yes ❑ No 1h Is the project located within a NC DCM Area of Environmental Concern (AEC)? ❑ Yes N No 2. Project Information 2a Name of project: Middleton Blvd Water Main Improvements 2b. County Brunswick County 2c. Nearest municipality / town: St. James 2d. Subdivision name: N/A 2e. 3. NCDOT only, T.I.P. or state N/A project no Owner Information 3a. Name(s) on Recorded Deed. Various NC DOT Rights -of -Way 1 2 2016 3b Deed Book and Page No IN, ER ES 3c. Responsible Party (for LLC if applicable): FER PERMITTING 3d Street address: 3e. City, state, zip - 3f Telephone no.: 3g Fax no 3h Email address - Page 1 of 12 PCN Form — Version 1 3 December 10, 2008 Version 4. Applicant Information (if different from owner): 4a Applicant is: ❑ Agent ® Other, specify: County obtaining encroachment agreement from NC DOT for water line. 4b. Name. Mr. John Nichols; Assistant Director of Public Utilities 4c Business name (if applicable): Brunswick County 4d. Street address. 30 Government Center Dr. 4e. City, state, zip: Bolivia, NC 28422 4f. Telephone no.: (910) 253-2016 4g. Fax no - (910) 253-2022 4h. Email address: 5. Agent/Consultant Information (if applicable) 5a Name. Kim Williams 5b. Business name (if applicable): Land Management Group, Inc. 5c. Street address: 3805 Wrightsville Avenue, Suite 15 5d City, state, zip: Wilmington, NC 28403 5e. Telephone no: (910) 452-0001 5f. Fax no.- (910) 452-0060 5g Email address: kwilliams@lmgroup.net Page 2 of 12 B. Project Information and Prior Project History 1. Property Identification 1a Property identification no. (tax PIN or parcel ID): Various NC DOT Rights-of-Way 1b. Site coordinates (in decimal degrees): Latitude: 33.967018 N Longitude. -78 134241 W DD DDDDDD-DD.DDDDDD 1c Property size: 4,100 LF of NC DOT ROW 2. Surface Waters 2a. Name of nearest body of water (stream, river, etc.) to River Swamp proposed project- 2b Water Quality Classification of nearest receiving water: C; SW 2c. River basin Lumber River Basin 3. Project Description 3a. Describe the existing conditions on the site and the general land use in the vicinity of the project at the time of this application: Project area consists of a maintained DOT right-of-way along Hwy 211 and Seafield Drive. 3b. List the total estimated acreage of all existing wetlands on the property: 1 acre 3c. List the total estimated linear feet of all existing streams (intermittent and perennial) on the property: N/A 3d. Explain the purpose of the proposed project: The purpose of this project is to improve water pressure and fire flows within the St. James development. The proposed water main will be 16" diameter along EF Middleton Blvd and 12" along Seafield Dr. The water main will be connecting to Brunswick County's existing water system at the intersection of EF Middleton Blvd and NC 211 as well as at the end of the existing main on Seafield Dr. 3e. Describe the overall project in detail, including the type of equipment to be used: The applicant will dig a trench along the road and install the waterline A 20' wide construction corridor will be used. The proposed water main will be 16" diameter along EF Middleton Blvd and 12" along Seafield Dr. Material removed from the trench will be stockpiled in adjacent upland areas within the ROW. Once the pipe is installed, the trench will then be returned to pre-construction grades. In wetland areas, organic material removed from the trench will be returned to the top 12" and the area will be seeded. Standard construction equipment will be used. 4. Jurisdictional Determinations 4a. Have jurisdictional wetland or stream determinations by the Corps or State been requested or obtained for this property / ® Yes ❑ No ❑ Unknown project (including all prior phases) in the past. Comments* 4b. If the Corps made the jurisdictional determination, what type ®Preliminary El Final of determination was made? 4c. If yes, who delineated the jurisdictional areas? Agency/Consultant Company: Name (if known): Corey Novak Other: LMG 4d. If yes, list the dates of the Corps jurisdictional determinations or State determinations and attach documentation. Part of the project area has a valid JD under an existing permit for the Reserve at St James (Action ID# 2002-00768) The other portions of the site were approved by John Policarpo of the USACE in the field on 4/26/16. 5. Project History 5a. Have permits or certifications been requested or obtained for ❑ Yes ® No ❑ Unknown this project (including all prior phases) in the past? 5b. If yes, explain in detail according to "help file" instructions. Page 3 of 12 PCN Form — Version 1 3 December 10, 2008 Version B. Project Information and Prior Project History 6. Future Project Plans 6a Is this a phased project? ❑ Yes ® No 6b. If yes, explain. Page 4 of 12 C. Proposed Impacts Inventory 1. Impacts Summary la Which sections were completed below for your project (check all that apply): ® Wetlands ❑ Streams - tributaries ❑ Buffers ❑ Open Waters ❑ Pond Construction 2. Wetland Impacts N/A If there are wetland impacts proposed on the site, then complete this question for each wetland area impacted. 2a. 2b. 2c. 2d. 2e. 2f. Wetland impact Type of jurisdiction number — Type of impact Type of wetland Forested (Corps - 404, 10 Area of impact Permanent (P) or (if known) DWQ — non -404, other) (acres) Temporary WA ❑ P ®T Utility Line Installation Non -riparian El Yes ® No ® Corps ® DWQ 0.061 WB ❑ P ®T Utility Line Installation Non -riparian El Yes ® No ® Corps ® DWQ 0.059 WC ❑ P ®T Utility Line Installation Non -riparian El Yes ® No ® Corps ® DWQ 0.104 WD ❑ P ®T Utility Line Installation Non -riparian El Yes ® No ® Corps ® DWQ 0.009 WE ❑ P ®T Utility Line Installation Non -riparian El Yes ® No ® Corps ® DWQ 0.036 WF ❑ P ® T Utility Line Installation Non -riparian ❑ Yes ❑ No ® Corps ® DWQ 0.405 WG ❑ P ®T Utility Line Installation Non-nparian El Yes ® No ® Corps ® DWQ 0.407 WH [:I PMT Utility Line Installation Non -riparian No ® No ® Corps ® DWQ 0.034 2g. Total wetland impacts 1.11 ac 2h Comments: 3. Stream Impacts N/A If there are perennial or intermittent stream impacts (including temporary impacts) proposed on the site, then complete this question for all stream sites impacted. 3a. 3b 3c. 3d. 3e. 3f. 3g. Stream impact Type of impact Stream name Perennial Type of jurisdiction Average Impact number - (PER) or (Corps - 404, 10 stream length Permanent (P) or intermittent DWQ — non -404, width (linear Temporary (T) (INT)? other) (feet) feet) S1 ❑ P ❑ T ❑ PER ❑ Corps ❑ INT - ❑ DWQ S2 ❑ P ❑ T ❑ PER ❑ Corps ❑ INT ❑ DWQ S3 ❑ P ❑ T ❑ PER ❑ Corps ❑ INT ❑ DWQ 3h Total stream and tributary impacts 3i. Comments: Page 5 of 12 PCN Form — Version 1.3 December 10, 2008 Version 4. Open Water Impacts: N/A If there are proposed impacts to lakes, ponds, estuaries, tributaries, sounds, the Atlantic Ocean, or any other open water of the U.S then individually list all open water impacts below. 4a Open water impact number — Permanent (P) or Temporary 4b. Name of waterbody (if applicable) 4c. Type of impact 4d. Waterbody type 4e. Area of impact (acres) 01 []PEI T 02 ❑P❑T 03 ❑P❑T 04 ❑P❑T 4f. Total open water impacts 4g. Comments: 5. Pond or Lake Construction: NIA If pond or lake construction proposed, then complete the chart below. 5a. Pond ID number 5b. Proposed use or purpose of pond 5c. Wetland Impacts (acres) 5d. Stream Impacts (feet) 5e. Upland (acres) Flooded Filled Excavated Flooded Filled Excavated Flooded P1 Stormwater P2 5f. Total 5g Comments: 5h. Is a dam high hazard permit required? ❑ Yes ❑ No If yes, permit ID no: 5i. Expected pond surface area (acres): 5j Size of pond watershed (acres): 5k Method of construction. Page 6 of 12 6. Buffer Impacts (for DWQ): N/A If project will impact a protected riparian buffer, then complete the chart below. If yes, then individually list all buffer impacts below If any impacts require mitigation, then you MUST fill out Section D of this form. 6a. ❑ Neuse ❑ Tar -Pamlico ❑ Other: Project is in which protected basin? ❑ Catawba ❑ Randleman 6b. 6c. 6d. 6e. 6f. 6g. Buffer impact number - Reason Buffer Zone 1 impact Zone 2 impact Permanent (P) or for Stream name mitigation (square feet) (square feet) Temporary T impact 131 ❑P❑T -required? El Yes ❑ No B2 ❑P❑T ❑Yes ❑ No B3 ❑ P ❑ T ❑ Yes ❑ No 6h. Total buffer impacts 61. Comments: Page 7 of 12 D. Impact Justification and Mitigation 1. Avoidance and Minimization - 1 a Specifically describe measures taken to avoid or minimize the proposed impacts in designing project. The applicant has attempted to avoid and minimize impacts to jurisdictional areas as much as possible. All impacts will occur within a maintained DOT right-of-way and will be restored to pre-construction grade once the line is installed. 1 b. Specifically describe measures taken to avoid or minimize the proposed impacts through construction techniques. Silt fencing will be installed to prevent erosion into adjacent jurisdictional areas and wetland impact areas will be seeded. 2. Compensatory Mitigation for Impacts to Waters of the U.S. or Waters of the State 2a. Does the project require Compensatory Mitigation for impacts to Waters of the U.S. or Waters of the State? ❑ Yes ®No 2b If yes, mitigation is required by (check all that apply): ❑ DWQ ❑ Corps 2c. If yes, which mitigation option will be used for this project? ❑ Mitigation bank E] Payment to in-lieu fee program ❑ Permittee Responsible Mitigation 3. Complete if Using a Mitigation Bank: N/A 3a Name of Mitigation Bank: 3b Credits Purchased (attach receipt and letter) Type: Quantity. 3c. Comments: 4. Complete if Making a Payment to In-lieu Fee Program: N/A 4a. Approval letter from in-lieu fee program is attached. ❑ Yes 4b. Stream mitigation requested- N/A ' 4c. If using stream mitigation, stream temperature: ❑ warm ❑ cool ❑cold 4d Buffer mitigation requested (DWQ only): N/A square feet 4e. Riparian wetland mitigation requested: N/A acres 4f Non-riparian wetland mitigation requested N/A acres 4g. Coastal (tidal) wetland mitigation requested: N/A acres 4h Comments- 5. Complete if Using a Permittee Responsible Mitigation Plan: N/A 5a. If using a permittee responsible mitigation plan, provide a description of the proposed mitigation plan. Page 8 of 12 PCN Form — Version 1.3 December 10, 2008 Version 6. Buffer Mitigation (State Regulated Riparian Buffer Rules) — required by DWQ 6a Will the project result in an impact within a protected riparian buffer that requires ❑ Yes ® No buffer mitigation? 6b. If yes, then identify the square feet of impact to each zone of the riparian buffer that requires mitigation. Calculate the amount of mitigation required. NIA 6c. 6d. 6e. Zone Reason for impact Total impact Multiplier Required mitigation (square feet) (square feet) Zone 1 3 (2 for Catawba) Zone 2 1.5 6f. Total buffer mitigation required: 6g. If buffer mitigation is required, discuss what type of mitigation is proposed (e.g., payment to private mitigation bank, permittee responsible riparian buffer restoration, payment into an approved in -lieu fee fund). NIA 6h. Comments: NIA Page 9 of 12 E. Stormwater Management and Diffuse Flow Plan (required by DWQ) 1. Diffuse Flow Plan 1 a. Does the project include or is it adjacent to protected riparian buffers identified El Yes No within one of the NC Riparian Buffer Protection Rules? 1 b. If yes, then is a diffuse flow plan included? If no, explain why. ❑ Yes ❑ No Comments: 2. Stormwater Management Plan 2a What is the overall percent imperviousness of this project? None 2b. Does this project require a Stormwater Management Plan? ❑ Yes ® No 2c. If this project DOES NOT require a Stormwater Management Plan, explain why: No impervious cover is proposed with this project. 2d. If this project DOES require a Stormwater Management Plan, then provide a brief, narrative description of the plan: ❑ Certified Local Government 2e Who will be responsible for the review of the Stormwater Management Plan? ❑ DWQ Stormwater Program ❑ DWQ 401 Unit 3. Certified Local Government Stormwater Review: NIA 3a. In which local government's jurisdiction is this project? ❑ Phase II ❑ NSW 3b. Which of the following locally -implemented stormwater management programs ❑ USMP apply (check all that apply): ❑ Water Supply Watershed ❑ Other: 3c Has the approved Stormwater Management Plan with proof of approval been ❑ Yes ® No attached? 4. DWQ Stormwater Program Review: N/A ❑ Coastal counties ❑ HQW 4a. Which of the following state -implemented stormwater management programs apply ❑ ORW (check all that apply): ❑ Session Law 2006-246 ❑ Other: 4b. Has the approved Stormwater Management Plan with proof of approval been ❑ Yes ❑ No attached? 5. DWQ 401 Unit Stormwater Review: N/A 5a Does the Stormwater Management Plan meet the appropriate requirements? ❑ Yes ❑ No 5b Have all of the 401 Unit submittal requirements been met? ❑ Yes ❑ No Page 10 of 12 PCN Form — Version 1.3 December 10, 2008 Version F. Supplementary Information 1. Environmental Documentation (DWQ Requirement) la Does the project involve an expenditure of public (federal/state/local) funds or the ® Yes ❑ No use of public (federal/state) land? 1 b. If you answered "yes" to the above, does the project require preparation of an environmental document pursuant to the requirements of the National or State ❑ Yes ® No (North Carolina) Environmental Policy Act (NEPA/SEPA)? 1 c. If you answered "yes" to the above, has the document review been finalized by the State Clearing House? (If so, attach a copy of the NEPA or SEPA final approval ❑ Yes ❑ No letter.) Comments, 2. Violations (DWQ Requirement) 2a. Is the site in violation of DWQ Wetland Rules (15A NCAC 2H .0500), Isolated Wetland Rules (15A NCAC 2H .1300), DWQ Surface Water or Wetland Standards, ❑ Yes ® No or Riparian Buffer Rules (15A NCAC 2B .0200)? 2b. Is this an after -the -fact permit application? ❑ Yes ® No 2c. If you answered "yes" to one or both of the above questions, provide an explanation of the violation(s): 3. Cumulative Impacts (DWQ Requirement) 3a. Will this project (based on past and reasonably anticipated future impacts) result in ❑ Yes ® No additional development, which could impact nearby downstream water quality? 3b. If you answered "yes" to the above, submit a qualitative or quantitative cumulative impact analysis in accordance with the most recent DWQ policy. If you answered "no," provide a short narrative description. Water line providing water service to areas already developed and is needed to improve water pressure. 4. Sewage Disposal (DWQ Requirement) 4a. Clearly detail the ultimate treatment methods and disposition (non -discharge or discharge) of wastewater generated from the proposed project, or available capacity of the subject facility. Project will provide water to the community. No wastewater will be generated by project. Page 11 of 12 PCN Form — Version 1.3 December 10, 2008 Version 5. Endangered Species and Designated Critical Habitat (Corps Requirement) 5a. Will this project occur in or near an area with federally protected species or, ® Yes ❑ No habitat? 5b. Have you checked with the USFWS concerning Endangered Species Act ❑ Yes ® No impacts? E] Raleigh 5c. If yes, indicate the USFWS Field Office you have contacted. ❑ Asheville 5d. What data sources did you use to determine whether your site would impact Endangered Species or Designated Critical Habitat? The NC Natural Heritage Program GIS layer was used to determine the presence of federally listed species No federally protected species are known to occur within the project area. There is a NCDOT mitigation site and the BSL Wetland Complex near the project area. The line will be installed within a maintained DOT ROW, which is outside of their mitigation site (which includes wetlands on either side). 6. Essential Fish Habitat (Corps Requirement) 6a. Will this project occur in or near an area designated as essential fish habitat? ❑ Yes ® No 6b. What data sources did you use to determine whether your site would impact Essential Fish Habitat? The NOAA Fisheries Essential Fish Habitat Mapper GIS program was used to determine the presence of Essential Fish Habitat. No EFH was noted within the project area. 7. Historic or Prehistoric Cultural Resources (Corps Requirement) 7a. Will this project occur in or near an area that the state, federal or tribal governments have designated as having historic or cultural preservation ❑ Yes ® No status (e g., National Historic Trust designation or properties significant in North Carolina history and archaeology)? 7b What data sources did you use to determine whether your site would impact historic or archeological resources? The NC State Historic Preservation Office HPOWEB GIS mapping resource was used to determine the presence of cultural or historic resources. No cultural or historical resources were noted within or adjacent to the site. 8. Flood Zone Designation (Corps Requirement) 8a Will this project occur in a FEMA -designated 100 -year floodplain? ❑ Yes ® No 8b. If yes, explain how project meets FEMA requirements: - 8c What source(s) did you use to make the floodplain determination? The NC Floodplain Mapping Information System website was used to determine the boundaries of the 100 -year floodplain. I � Kim Williams 7/8/2016 Applicant/Agent's Printed Name Date Applicant/Agent's Signature (Agent's signature is valid only if an authorization letter from the applicant is provided ) Page 12 of 12 AGENT AUTHORIZATION FORM TO WHOM IT MAY CONCERN: I/we, the undersigned, hereby authorize Land Management Group, Inc. to act as our agent in the preparation and representation of information related to the Section 404/401 permit application for Middleton Blvd Water Main Improvements project. All questions in regards to this project should be directed to Land Management Group, Inc. Sincerely, a/a/ Applicant Print Name Date ProjectR. m� AreaJ", O„ 1110 Sources: Esri, HERE, DeLorme, USGS, Intermap, increment P Corp., NRCAN, Esri Japan, METI, Esri China (Hong Kong), Esri (Thailand), TomTom, Mapmylndia, © OpenStreetMap contributors, and the GIS User Community 3oundaries are approxin ire not meant to be absolute. Map Source: ArcGIS World Street Map SCALE 1" = 1 mile Middleton Blvd LMG Water Main Improvements Figure 1 Brunswick County, NC :1 www.lmgroup.net Vicinity Map 3805 Wrightsville Avenue July 2016 Wilmington, NC 28403 LMG # 40-16-074 Phone: 910.452.0001 Fax: 910.452.0060 i S J V `f d tD ` f MidtCr aart I r ,• _ orn x� Project Area a jj} Ir - X J _ a wa, y _ _ r 4 'y g• . - ::---3"' �.+.�.....`� _ ._ _. � l\ •Ma \ �+ -jam+ .�� ...tb • - ,' A" �y � It 4 h , r. -rte _ 1. \ •^-.., w u _ itkk f �.. a I Boundaries are approximate and are not meant to be absolute. Map Source: USGS Brunswick County Mosaic Middleton Blvd Water Main Improvements Brunswick County, NC July 2016 LMG # 40-16-074 LMG v" „IArtq 1111,I ;' www.lmgroup.net 3805 Wrightsville Avenue Wilmington, NC 28403 Phone: 910.452.0001 Fax: 910.452.0060 SCALE 1" = 2000' Figure 2 USGS Topographic Map Legend Gt: Grifton fine sandy loam Lo: Leon fine sand Ma: Mandarin fine sand Mu: Murville mucky fine sand 3oundanes are approximate and are not meant to be absolute. Map Source: NRCS Soil Survey SCALE 1" =1000' Middleton Blvd LMG Water Main Improvements Figure 3 Brunswick County, NC www.lmgroup.net Soils Map 3805 Wrightsville Avenue July 2016 Wilmington, NC 28403 LMG # 40-16-074 Phone: 910.452.0001 Fax: 910.452.0060 Source: Esri,i DS, USDA, U the GIS User Boundaries are approximate and are not meant to be absolute. Map Source: 2014 GIS World Imagery Aerial Photography M ommomi SCALE 1" =1000' Middleton Blvd LMG Water Main Improvements `'`"` Figure 4 Brunswick County, NC www.lmgroup.net Aerial Photograph 3805 Wrightsville Avenue July 2016 Wilmington, NC 28403 LMG # 40-16-074 Phone: 910.452.0001 Fax: 910.452.0060 NOTE_ This is not a survey. All boundaries and distances are considered approximate. This represents a preliminary sketch prepared from field notes. A survey of delineated P :` areas and review and approval by the US Army Corps of Engineers is recommended prior to specific site planning. ' _r1wNC 2 -� x ¢ . ,e� 3 �Y 7 { H:W e+ `z A 7�� 00000. 'Legend Project area with no current JD Project area with current JD Flagged wetland lines Current JD wetlands and boundary • Data points "Boundaries are approximate and are not meant to be absolute. Map Source 2012 NC OneMap Aerial Photography C ne, W � Y � %i w�J � • i SCALE 1" = 600' (when printed at 11"x17") St. James Water Line LMG Brunswick County, NC _ '; k'1 Preliminary www.In,group,net Upland/Wetland Sketch April 2016 3805 Wrightsville Avenue Overview LMG # 40-16-074 Wilmington, NC 28403 Phone: 910.452.0001 Fax: 910.452.0060 NOTE: This is not a survey. All boundaries and distances are considered approximate. This represents a preliminary sketch prepared from field notes. A survey of delineated areas and review and approval by the US Army Corps of Engineers is recommended prior .. to specific site planning."' NC 211 aT r P , ,p s i TSPS'.: J i i ;.Y' •�. �r ,M 53 � � : � t � { , y ,� T•'i"'- _ _'S. ..Aye .� a`.. _ i.ri.` '�'✓i� ,gip'. i r fi i x r. y 1. t J��[ �w%?'..Y� of a u I i �- a I 11 'fig' � •+ yP,� �: �.-,'" ,�:'.e�' y e _ _, Ays Al`:., �,r"r .,•..� sty i47` , I r:a r"t,. M+��y.,�,y �r .ua.��' *�. t• 'x Y" rr 4, Q"„y.�[y w'r� Rr” I x` 1 itl'f`:f�"''a'rrM' „fin., A� S ,.t t`rY,• ice* .?• r a - " Mi . , • '+""f �1} t� �, #r►'J`- +; ' A '=» r*• a P Legend Project area with no current JD Project area with current JD Flagged wetland lines Current JD wetlands and boundary Data points Wetlands *Boundaries are approximate and are not meant to be absolute. SCALE 1" = 200' Map Source: 2012 NC OneMap Aerial Photography (when printed at 11"x17") St. James Water Line LMG Brunswick County, NC _ Preliminary www.1n,grOL1P.1et Upland/Wetland Sketch April 2016 3805 Wrightsville Avenue Inset 1 LMG # 40-16-074 Wilmington, NC 28403 Phone: 910.452.0001 Fax: 910.452.0060 NOTE. This is not a survey. All boundaries and distances are considered approximate. This represents a preliminary sketch prepared from field notes. A survey of delineated areas and review and approval by the US Army Corps of Engineers is recommended prior to specific site planning. 13 ApMr` i '0., �►."- {�.• ^#� ,'�� y � x. `fir ,.d v l :�["'r:' : yry�}�,��. {* KY7, Y Mir' t '�'�'.. 'I R•!' �►y.� s� •; x�i` ` 1 jlliL '�k � �' � � • ",rft i j� hd� •at �' .<,,, +15 rn� ��" �;: �� '� �' � ja,� #."M".� a`� • e, z °� '"i`"""' :'ex`s 1 .� "6 4 _ �# ,, ' s°{, t. ✓ z' *' y r �$ 4 44 XA 41 »*,f*' . � -§^ i' .. r't` �� : a a } P iv,..�� �-,+�li�, �ytuF .L ♦ :� iFi��Y do '- * y .rt y by°'• � ..� '� Jw 4� 'iF� rt +pry` `" `�i",,�y;�':,` �,Y ii� { ., t ,. . %A �h7' v a �♦ , � tr '°`yNrn' j�.s�,.+ .�r� ^iq+.� « � • n"",->' a: �,t, do-. a i.. "« , a , i t �• ' to be absolute. Map Source: 2012 NIC OneMap Aerial Photography At : Wetlands: a OF&SAM R. S.j { 1, k y , � r. X'4� �..�• h� Project area with current JD Flagged wetland lines Current JD wetlands and boundary r Data points SCALE 1" = 200' (when printed at 11"x17") St. James Water Line LMG Brunswick County, NC _ ""�`"''�' Preliminary WWW n,grOLIp.net Upland/Wetland Sketch April 2016 3805 Wrightsville Avenue Inset 2 LMG # 40-16-074 Wilmington, NC 28403 Phone: 910.452.0001 Fax: 910.452.0060 v ao rn co 0cCD 00C D M0 00 r� D� u 0 + + 0 N O O D D -n rl OZ� DO 0 ZD z� o0 RZ Mcn >OK > MrZ N ?ITl �O R o -f - Z (Jl O O 0 o 0 O O N + ° S N O o �m yl f A � O F Q n E 9 f'r o ZZ 9°p Q C) _ F o m ; 8 Q' n ' b 4 1.2 N k+ rt N O a O O o_ w O A O O O 0 2p�2 m �> } �F I Z> O 9 I j I x m 1> m0:5 Ln W g p s z i n z I i ~ Fv-z y� I I o ;zo I 'I i 1 I o` f I I I �I I ;Nq�c I I I c 61 r ; MO { I ' r I 1 r I NY I I -7 -1 =RH4 b En I i I I I I I li I, I I r r , j I ' I j ' j � r I I I i i i i n 1 I I 1 I I j zz i I I r II -- I' >- mx 1 co =I I r ;o ..�_;�___- Z _ __ _ - ____ _ __ O 1 , 0 I I I T cil I --_i jjI I I I I I i I I I i I I j r _ I I r I I S j j I I f I i I i I I I g O A O O O O^» Z MM m 0 2p�2 m �> } �F I Z> O 9 Tm Z y _ ^fin Z m0:5 Ln W g p s z i n z I r— ~ Fv-z y� I I o ;zo I. II 'I i Inn >mx o` I E I �I I ;Nq�c I I I c O^» Z MM m 0 2p�2 m �> tI I� �I �F I Z> O � F IV t i I > -0F LAC >f+l>Z ~ Fv-z m ` o ;zo I. II m Inn >mx o` >z_ I �I 61 Drj �NY ; MO NY aOV -7 -1 =RH4 b En I I I I I � I _ m � — I I I I I I I I I I I / I / I / / I I I I I I I I I I I I .I I I I I I I I I I N I I I I i 1 � I I 1 i IVVY E Q3o' � o ^ woo n AZA j S 3 Oo„ MM A o >t ol eo 0 m N W N 0 N J O N 0 w 0 4 0 MATCHLINE STA 24+00 SEE SHEET C-1 � 1 m ny I 2 v�s � n I a mm Z�jYZ jA ym z P I.1X07 I O mw I / 11�� a � r/vlare• Ig I n' /I 1 ,I i I 1 � I \ <� f � G z�IDi7� I � mr1i y < s 0 Z �+ I cw Iso' R 1 t, D� D MK o N�� Oz. DD ZD o Z O 'Z N G O pbT + �/�TN V / TV TR y M NT " O K �mD o m �� F O wrZ cpm �O ; + Z� CL o 0 O O I 0 1 pAA m y >s iii yy� L i t I N m, <pl 2 � I 2 n n II N 0 MATCHLINE STA 24+00 SEE SHEET C-1 � 1 m ny I 2 v�s � n I a mm Z�jYZ jA ym z P I.1X07 I O mw I / 11�� a � r/vlare• Ig I n' /I 1 ,I i I 1 � I \ <� f � G z�IDi7� I � mr1i y < s 0 Z �+ I cw Iso' R 1 t, I V I I I I j I I I i t I N m, <pl f i l I i 1 I I 1 , � I I � , i I ' I I I i I I Ii I i I I I I I I —F -FT I 1 I I I !0 I I I I 11 I j I rm z i I I 0 I I I I I I ! I I jl I i { I �0 t Dmi I II _ I I I I I I I I I i I I I — r— -' I 1 I I I � I o ;f' I I 1 I � 1 I I I it - I III, i f 1 j i I 1 , t , I i I I I I MATCHLINE STA 24+00 SEE SHEET C-1 � 1 m ny I 2 v�s � n I a mm Z�jYZ jA ym z P I.1X07 I O mw I / 11�� a � r/vlare• Ig I n' /I 1 ,I i I 1 � I \ <� f � G z�IDi7� I � mr1i y < s 0 Z �+ I cw Iso' R 1 t, A O b O 0 gm 0 D p F rrirrrrrrr.r. �� N , D E5 O cn ADD zm ooh EZ , o � T Ir NK v N N C N 0A ' J, N Oo /D ' VZ 1^ Ulm � o O O n +3� 0 N o � N o 3 0o Awn N O+ o+ 0 m^ � m o � + >< N m b O 0 N O O m N m N V 0 0 A O b O 0 J O � gm D cWDD �� N , D E5 O cn ADD zm ooh EZ , o � T Ir NK v N N o D 0A ' J, N Oo /D ' VZ 1^ Ulm �+ moN O O 0 N o N O+ o+ 0 0 N � bbd o N n }op( rrD O > > '�<G Qy ! N A + QB p ^ N O T C N n 0 Z sx j i I J O � I � ' I i sx j i I I I I I I � j I I I I i i I I i I I 1 I I I I I I , , I l i I I I I I I i I 1 I 00 -m A rI i N I rj + i I I � ' I I ' , I I I , , I , I I I i r t la �a 1 , I I I I i I II I I I I I I I I I i , MATCHLINE STA 39+50 SEE SHEET C-2 I I I I �Iwra,» I I I I i 1 L� 0 m 0 a w 0 g o 0 o MATCHLINE STA 55+00 SEE SHEET C-3 0 � 1 tlunmq„ I f 1(t• '1 :moo �� uuunt•`I'""` 1 m 0 a w 0 g o 0 o MATCHLINE STA 55+00 SEE SHEET C-3 � I � 1 ; I 1(t• '1 1 I INS 1 t ` � 2 f N Ott I, i 1 m a 1 • 1 I 1 T 1 ' C) rII • A q r IN11: , 1 I _ I I I I r I i i I I Z N'(n .T�1 !••I I - In m m t- - - r- --- i —I I I I I I I I I I I' I I ' I - ' --_- • - i I �NA I I ED O i I i I Im� I I I i I j I I i i +jy I z O . I I f r i r I 11I O I I I f i I I I nim II11 II � aOx on 2� zC-) Z N D ' m = C N I ml rl! D AZ �i m m I + iI 1 i Div Z " I I � I I I A m I I+I I I N MI M, • m E i I I I =I MK m I 1 11it <O irlll V I � � � 1 1(t• '1 1 INS 1 t ` � 2 f N Ott I, i 1 m 1 • 1 I C) rII • A q r IN11: I •I,� I fE 1 I •L I •I,.I I Z N'(n .T�1 !••I I - In m m ED O i I I UI O . I I 11I O zC-) Z N D m = C N I rl! D AZ �i I m + I m I M • m E i io„0 11it <O irlll V rz r 1 ��I 0 . + O O °u c i c c 0 0 m O O 0 V N O V 4 0 N m V m 0 0 �o m Oom Kzm Z O �'� m OmN N z z £ r.+ 0 sy � m > C S.l�7A Z D Z D O av I IArI . I I I I I I I I I ft IN 07 —BO ' ti I I I I �S I I f I �k 2 � _ vin�. am Pna r �o �o z 2nz m V i I I! I li I cn III I;I o^D� =rh. mm N r � I A xrc e. 7r,0 D fin'" + N m A OF �1 , DZ� cn �o m zo—.m Z ormo m N cn i I m I ?,�vrrin � —I Im 1 o'if Jm D I I I I I �I uo m l I I `j cn_ — i---F--- S r m x 0 0 I II r;h r I I I - 'r7ui i I i 1 1 i I I in m I I IIS J-- I � n Z— I I Ow I I I r+« j0+ri I I f I i C �a I F� { I i a n •N f Fm0 o ' I I ' I I I I I j vii m m � � I 11 I I i r ' RS 1 I I I� I l i i I I ( I I I I I I I 1 I I f I I — I I 2S I I I I I I o� , I I I I I I i t I I I , I I 1 I � { I _I I l 1 1 0 0 �o m Oom Kzm Z O �'� m OmN N z z £ r.+ 0 sy � m > C S.l�7A Z D Z D O av I IArI . I I I I I I I I I ft IN N m ak aZ < O m D m 6 0 2 N a) C 0 4 z y Z,0 c N 07 —BO ' ti I, vo 22 �S �k 2 � _ vin�. am Pna r �o �o z 2nz m V i I I! I li I cn III I;I o^D� =rh. mm N r � I A xrc e. 7r,0 D fin'" + N m A OF �1 , DZ� cn �o m zo—.m Z ormo m N cn i ,n9f ev mmZoN m I ?,�vrrin � —I A O N m ak aZ < O m D m 6 0 2 N a) C 0 4 z y Z,0 c N I, vo 22 I,I V i I I! I li I III I;I o^D� =rh. mm N !�I Mmrn r mmm.=.tt < m rp D I N } OF �1 , I I�� i N m ak aZ < O m D m 6 0 2 N a) C 0 4 z y Z,0 c N WETLAND IMPACT 'B' 2,561 SF g$4 & FKM4 EF MIDDLETON SR 1105 WATER MAIN IMPROVEMENTS WETLAND IMPACT AEA kND IMPACT 'A' 1,570 SF 2,652 SF WETLAND IMPACT 'D' 379 SF - WETLAND IMPACT 'C' 4,538 SF PULL BACK AREA HORIZONTAL WETLAND IMPACT 'H' DIRECTIONAL 1,467 SF DRILL tYS 7lAT��LIt G�-.d-`Ii®i► ��.! ®& ®f7i�11`�y�,��, T® 'Sitla��i�7lG '..MARMUM ` ®E D t • 1 — IVA t1V���rt1�1� PERMANENT SQUARE WETLAND FEET IMPACT AREA 2,561 FIRE HYDRANT 1 TOTAL 1 IMPACT 1,570 TEMPORARY WETLAND IMPACT AREA SQUARE FEET 'A' 2,652 'B' 2,561 'C' 4,538 'D' 379 'E' 1,570 'H' 1,467 TOTAL IMPACT 13,167 TEMPORARY WETLAND IMPACT AREAS SITE MAP 1 -w / J I 20' IMPACT - CORRIDOR WETLAND IMPACT "An (TYP) /r 2,652 SF t - EF - D / V -T- y IN �w �� - _ -w WETLAND IMPACT "Bn 2,561 SF v N�TQM�CREED v EF MIDDLETON SR 1105 WATER MAIN IMPROVEMENTS WETLAND 4,53 PULL BACK AREA PERMANENT SQUARE WETLAND FEET IMPACT AREA 2,561 FIRE HYDRANT 1 TOTAL 1 IMPACT 1,570 •• 0 100' 2091 TEMPORARY WETLAND IMPACT AREA SQUARE FEET W 2,652 "B" 2,561 °C' 4,538 "D" 379 "En 1,570 "H" 1,467 TOTAL IMPACT 13,167 TEMPORARY WETLAND IMPACT AREAS SITE MAP 2 20' IMPACT CORRIDOR (TYP) -W►+-WWW WETLAND IMPACT "E" 1,570 SF PULL BACK AREA PERMANENT SQUARE WETLAND FEET IMPACT AREA 2,561 FIRE HYDRANT 1 TOTAL 1 IMPACT 1,570 TEMPORARY WETLAND IMPACT AREA SQUARE FEET "A" 2,652 "B" 2,561 "C" 4,538 TDA 379 "E" 1,570 "Hn 1,467 TOTAL IMPACT 13,167 •• 0 100'•• v N K M&CREED v EF MIDDLETON SR 1105 WATER MAIN IMPROVEMENTS TEMPORARY WETLAND IMPACT AREAS SITE MAP 3 20' IMPACT CORRIDOR (TYP) / HORIZONTAL \ DIRECTIONAL \ DRILL HORIZONTAL DIRECTIONAL DRILL v MzK M&CREED v EF MIDDLETON SR 1105 WATER MAIN IMPROVEMENTS Y:. Proposed Fire Hydrant' WETLAND IMPACT "H' \ N`x`E�� `.t. t, 1,467 SF Poo{iosed ,Fire Hydrant • . (1 sf of permanent impact) PERMANENT SQUARE WETLAND FEET IMPACT AREA 2,561 FIRE HYDRANT 1 TOTAL 1 IMPACT 1,570 •• • •• ff-wt t i A ■ PULL BACK AREA TEMPORARY WETLAND IMPACT AREA SQUARE FEET W 2,652 "B" 2,561 "C" 4,538 "D" 379 "E" 1,570 'H" 1,467 TOTAL IMPACT 13,167 TEMPORARY WETLAND IMPACT AREAS SITE MAP 4 COUNTY Ut BKUNSV-T T T T OWNER Project Manager: John Nichols, PE EF MIDDLETON SR 1105 Brunswick County 250 Grey Water Rd NE Supply, NC 28462 Phone: 910-252-2860WATER MAIN IMPROVEMENTS SURVEYOR McKim & Creed, Inc. 243 North Front Street Wilmington, North Carolina 28401 Phone: 910-343-1048 Fax: 910-251-8282 TBoahn@mckimcreed.com Firm License F-1222 DESIGNER Tony Boahn, PE McKim & Creed, Inc. 243 North Front Street Wilmington, North Carolina 28401 Phone: 910-343-1048 Fax: 910-251-8282 TBoahn@mckimcreed.com Firm License F-1222 TYPE OF WORK: WATER TRANSMISSION MAIN CONSISTING OF 5,482 LF OF 16" C-905 PVC AND 1,165 LF OF 12" C-900 PVC i �W- A rte• °�L Ili. •, J DATE: 06/2016 SUBMITTAL: Permit Review U U 0 a ty b o � U U zz'- H O w U F" w Z 0 U � En a O A INDEX OF SHEETS 1 COVER G-1 GENERAL NOTES C-1 16" WATER MAIN PLAN AND PROFILE STA 10+00 TO STA 24+00 C-2 16" WATER MAIN PLAN AND PROFILE STA 24+00 TO STA 39+50 C-3 16" WATER MAIN PLAN AND PROFILE STA 39+50 TO STA 55+00 add discipline C-4 16" WATER MAIN PLAN AND PROFILE STA 55+00 TO STA 64+62 C-5 12" WATER MAIN PLAN AND PROFILE STA 64+62 TO 76+27 C-6 NC 211 CONNECTION DETAILS D-1 EROSION CONTROL DETAILS 1 of 5 GENERAL WATER DETAILS add discipline 2 of 5 GENERAL WATER DETAILS 3 of 5 GENERAL WATER DETAILS 4 of 5 GENERAL WATER DETAILS 5 of 5 GENERAL WATER DETAILS 1 of 7 GENERAL WATER & SEWER DETAILS add discipline 'MCH : (JPV 2 of 7 GENERAL WATER & SEWER DETAILS 3 of 7 GENERAL WATER & SEWER DETAILS DES: (AWB) 4 of 7 GENERAL WATER & SEWER DETAILS 5 of 7 GENERAL WATER & SEWER DETAILS CHK: (AWB) PROJECT NO. 6 of 7 GENERAL WATER & SEWER DETAILS 7 of 7 GENERAL WATER & SEWER DETAILS 00069-0043 SHEET NO. 1 GENERAL NOTES: 1. IMPROVEMENTS ARE TO BE CONSTRUCTED IN GENERAL ACCORDANCE WITH ALL BRUNSWICK COUNTY AND NCDEQ REGULATIONS, REFERENCE BRUNSWICK COUNTY SPECIFICATIONS FOR WASTEWATER/SEWER CONSTRUCTION AND PROJECT SPECIFICATIONS. 2. CONSTRUCTION ON THIS SITE IS AUTHORIZED BY PERMITS ISSUED BY THE NORTH CAROUNA DEPARTMENT OF ENVIRONMENTAL QUAUTY (NCDEQ). THE WORK IS SUBJECT TO INSPECTION AT ALL TIMES BY REPRESENTATIVES OF NCDEQ, BRUNSWICK COUNTY AND THE ENGINEER OF RECORD. THE PERMITS REQUIRE CERTIFICATION OF COMPLETION BY THE ENGINEER OF THE SYSTEMS PRIOR TO THE ISSUANCE OF FINAL OPERATIONAL APPROVAL BY NCDEQ. 3. CONTRACTOR SHALL VERIFY THE ACTUAL LOCATION AND ELEVATION FOR ALL UTILITIES, DRAINAGE, AND OTHER UNDERGROUND FACILITIES WHETHER SHOWN ON THE PLANS OR NOT, AND SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCIES OR CONFLICTS PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL VERIFY DEPTH & LOCATION OF UNDERGROUND UTILITIES AHEAD OF PIPE LAYING OPERATIONS. COORDINATION WITH THE ENGINEER IS REQUIRED TO ADJUST THE PIPE ALIGNMENT TO AVOID INSTALLATION OF BENDS AND UTILITY CONFLICTS WHERE POSSIBLE. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR THE COST OF LOCATING AND MARKING ALL EXISTING UNDERGROUND UTILITIES. 5. CONTRACTOR SHALL SUBMIT FIVE (5) COPIES OF SHOP DRAWINGS FOR ALL MATERIALS TO ENGINEER OF RECORD FOR APPROVAL PRIOR TO CONSTRUCTION. 6. CONTRACTOR SHALL CONDUCT OR ATTEND A PRE—CONSTRUCTION CONFERENCE ON SITE WITH THE ENGINEER OF RECORD, NCDEQ. NCDOT, AND OTHER INTERESTED PARTIES PRIOR TO CONSTRUCTION. 7. CONNECTION TO ANY EXISTING LINES SHALL BE BY THE CONTRACTOR IN THE PRESENCE OF BRUNSWICK COUNTY INSPECTION PERSONNEL. PLUG NEW CONNECTION THROUGHOUT CONSTRUCTION AND SUCCESSFUL COMPLETION OF TESTING, INSPECTION BY THE ENGINEER OF RECORD AND BRUNSWICK COUNTY, AND FINAL CONNECTION IS AUTHORIZED. B. MAINTAIN A MINIMUM OF 24 INCH VERTICAL SEPARATION BETWEEN STORM AND SANITARY SEWER OR INSTALL DUCTILE IRON PIPE ON SANITARY SEWER WITHIN 10 FEET EACH SIDE OF CROSSING. 9. UTILITY SERVICES SHALL NOT BE LOCATED UNDER DRIVEWAYS 10. BRUNSWICK COUNTY SHALL OWN AND MAINTAIN THE PROPOSED WATER MAIN UPON COMPLETION, INSPECTION, APPROVAL, AND ACCEPTANCE. 11. WATER MAINS, WITHIN OR PARALLEL TO ROAD RIGHTS OF WAY, MUST HAVE A MINIMUM OF 36" COVER, UNLESS OTHERWISE NOTED, MEASURED FROM THE ROAD EDGE OF PAVEMENT ELEVATION. CONTRACTOR SHALL MAINTAIN 1:1 SLOPE FROM EDGE OF PAVEMENT SO AS NOT TO COMPROMISE ROAD STRUCTURE IN ALL LOCATIONS EXCEPT PLANNED WORK WITHIN THE ROADWAY. 12. PRIOR TO ROAD CLOSURES, CONTRACTOR SHALL NOTIFY 911 EMERGENCY SERVICES OF LOCATION AND TIMES OF CLOSURE. 13. TEMPORARY CONCRETE WASHOUT FACILITIES SHALL BE LOCATED A MINIMUM OF 50 FEET FROM STORM DRAIN INLETS, OPEN DRAINAGE FACILITIES, AND WATERCOURSES, UNLESS DETERMINED NOT FEASIBLE BY THE ENGINEER. CONTRACTOR MAY USE THE EXCAVATED TRENCH FOR CONCRETE WASHOUT AS AN ALTERNATIVE TO DESIGNATING A SPECIFIED WASHOUT AREA. TESTING/INSPECTION: 1. NOTIFY THE ENGINEER AND BRUNSWICK COUNTY AT LEAST ONE (1) WEEK BEFORE STARTING CONSTRUCTION OF WATER FACILITIES. THE ENGINEER AND BRUNSWICK COUNTY SHALL WITNESS PRESSURE TESTING OF THE WATER SYSTEM. THE CONTRACTOR SHALL FURNISH, SECURE, AND PROVIDE ALL NECESSARY TESTING MATERIALS, EQUIPMENT, PROCEDURES AND CERTIFIED LABORATORY TEST RESULTS FOR USE WITH ENGINEERS FINAL CERTIFICATION OF COMPLETION. CONNECTIONS TO EXISTING INFRASTRUCTURE SHALL BE COORDINATED WITH BRUNSWICK COUNTY ONE WEEK IN ADVANCE. PLEASE CONTACT DON WILLIAMS 2. MAINS MUST BE HYDROSTATICALLY TESTED PER BRUNSWICK COUNTY SPECIFICATIONS AND CONTRACT DOCUMENTS AND UNDER THE SUPERVISION OF A BRUNSWICK COUNTY INSPECTOR AND THE ENGINEER. 3. SECURE FINAL OPERATIONAL APPROVAL FROM BRUNSWICK COUNTY AND NCDEQ PRIOR TO ACTIVATION OF THE SYSTEM. 4. TRENCH BACKFILL AND COMPACTION TESTING SHALL BE PERFORMED BY A CERTIFIED SOILS LABORATORY UNDER ALL PAVED AREAS. BACKFILL MATERIAL FROM THE BOTTOM OF TRENCH TO WITHIN SIX (6) INCHES OF THE SUBGRADE SHALL HAVE A MINIMUM DRY DENSITY OF 95% AS DEFINED BY THE STANDARD PROCTOR TEST. 5. THE CONTRACTOR SHALL SUPPLY THE ENGINEER WATER MAIN MEASUREMENTS INCLUDING STATIONS AND DEPTHS OF ALL FITTINGS, VALVES, ETC. SUITABLE FOR PREPARATION OF FINAL RECORD DRAWINGS. DEPTHS SHALL BE MEASURED TO NEAREST 0.1 FOOT. STANDARD EROSION CONTROL NOTES' 1. IF NECESSARY, SLOPES WHICH EXCEED EIGHT (8) VERTICAL FEET SHOULD BE STABILIZED WITH SYNTHETIC OR VEGETATIVE MATS, IN ADDITION TO HYDROSEEDING. IT MAY BE NECESSARY TO INSTALL TEMPORARY SLOPE DRAINS DURING CONSTRUCTION. TEMPORARY BERMS MAY BE REQUIRED UNTIL THE SLOPE IS BROUGHT TO GRADE. 2. STABILIZATION MEASURES SHALL BE INITIATED AS SOON AS PRACTICABLE IN PORTIONS OF THE SITE WHERE CONSTRUCTION ACTIVITIES HAVE TEMPORARILY OR PERMANENTLY CEASED, BUT IN NO CASE MORE THAN FOURTEEN (14) DAYS AFTER WORK HAS CEASED, EXCEPT AS FOLLOWS: WHERE STABILIZATION BY THE 14TH DAY IS PRECLUDED BY SNOW COVER OR FROZEN GROUND CONDITIONS STABILIZATION MEASURES MUST BE INITIATED AS SOON AS PRACTICABLE. WHERE CONSTRUCTION ACTIVITY ON A PORTION OF THE SITE IS TEMPORARILY CEASED, AND EARTH—DISTURBING ACTIVITIES WILL BE RESUMED WITHIN 14 DAYS, TEMPORARY STABILIZATION MEASURES DO NOT HAVE TO BE INITIATED ON THAT PORTION OF THE SITE. 3. ALL SEDIMENT AND EROSION CONTROL DEVICES SHALL BE INSPECTED AT LEAST ONCE EVERY SEVEN (7) CALENDAR DAYS. IF SITE INSPECTIONS IDENTIFY DEVICES THAT ARE DAMAGED OR ARE NOT OPERATING EFFECTIVELY, MAINTENANCE MUST BE PERFORMED AS SOON AS PRACTICAL OR AS REASONABLY POSSIBLE AND BEFORE THE NEXT RAINFALL EVENT WHENEVER PRACTICABLE. 4. PROVIDE SILT FENCE AND/OR OTHER CONTROL DEVICES, AS REQUIRED, TO CONTROL SOIL EROSION DURING UTILITY CONSTRUCTION. ALL DISTURBED AREAS SHALL BE CLEANED, GRADED, AND STABILIZED WITH GRASSING IMMEDIATELY AFTER THE UTIUTY INSTALLATION. FILL, COVER, AND TEMPORARY SEEDING AT THE END OF EACH DAY ARE REQUIRED. IF WATER IS ENCOUNTERED WHILE TRENCHING, THE WATER SHOULD BE FILTERED TO REMOVE ANY SEDIMENTS BEFORE BEING PUMPED BACK INTO ANY WATERS OF THE STATE(WOS). 5. ALL EROSION CONTROL DEVICES SHALL BE PROPERLY MAINTAINED DURING ALL PHASES OF CONSTRUCTION UNTIL THE COMPLETION OF ALL CONSTRUCTION ACTIVITIES AND ALL DISTURBED AREAS HAVE BEEN STABILIZED. ALL MEASURES SHOWN ON PLANS SHALL BE INSTALLED UNLESS DIRECTED OTHERWISE. ADDITIONAL CONTROL DEVICES MAY BE REQUIRED DURING CONSTRUCTION IN ORDER TO CONTROL EROSION AND/OR OFFSITE SEDIMENTATION. ALL TEMPORARY CONTROL DEVICES SHALL BE REMOVED ONCE CONSTRUCTION IS COMPLETE AND THE SITE IS STABILIZED. 6. THE CONTRACTOR MUST TAKE NECESSARY ACTION TO MINIMIZE THE TRACKING OF MUD ONTO PAVED ROADWAY(S) FROM CONSTRUCTION AREAS AND THE GENERATION OF DUST. THE CONTRACTOR SHALL DAILY REMOVE MUD/SOIL FROM PAVEMENT, AS MAY BE REQUIRED. 7. TEMPORARY DIVERSION BERMS AND/OR DITCHES WILL BE PROVIDED AS NEEDED DURING CONSTRUCTION TO PROTECT WORK AREAS FROM UPSLOPE RUNOFF AND/OR TO DIVERT SEDIMENT—LADEN WATER TO APPROPRIATE TRAPS OR STABLE OUTLETS. B. ALL WOS, INCLUDING WETLANDS, ARE TO BE FLAGGED OR OTHERWISE CLEARLY MARKED IN THE FIELD. A DOUBLE ROW OF SILT FENCE IS TO BE INSTALLED IN ALL AREAS WHERE A 50—FOOT BUFFER CAN'T BE MAINTAINED BETWEEN THE DISTURBED AREA AND ALL WOS. A 10—FOOT BUFFER SHOULD BE MAINTAINED BETWEEN THE LAST ROW OF SILT FENCE AND ALL WOS. 9. LITTER, CONSTRUCTION DEBRIS, OILS, FUELS, AND BUILDING PRODUCTS WITH SIGNIFICANT POTENTIAL FOR IMPACT (SUCH AS STOCKPILES OF FRESHLY TREATED LUMBER) AND CONSTRUCTION CHEMICALS THAT COULD BE EXPOSED TO STORM WATER MUST BE PREVENTED FROM BECOMING A POLLUTANT SOURCE IN STORM WATER DISCHARGES. .e❑ —W_ —DHE C- -X— LEGEND MAILBOX POWER POLE —LOC— TV PEDESTAL EX. WATER LINE OVERHEAD ELECTRIC GAS LINE FENCE UNE RIGHT OF WAY CL CREEK SILT FENCE LIMITS OF CLEARING gx sx ♦ Mk DATE: JUNE 2D43 SCALE •`� ,cG¢T--•`S v MCI�/j ( D EF MIDDLETON SR 1105 MCE PROD. of 00069-0043 2.cif`^ DRAWN JPy HORIZONTAL N/A SEAL; = . �% BRUNSWICK COUNTY WATER MAIN IMPROVEMENTS DESIGNED CHECKED AW�9 VERTICAL: Cj-1 e Wil North Front Street NORTH CAROLINA Wilmington, North Carolina : (91 PROJ. MGR. AWB N/A Phone: (910)343-1048, Fax: (910)251-8282 �/Alrywy.}� U� F-1222 D GENERAL NOTES STAnS: ISSUED FOR PERMITTING 16V.ND. OESCNPTIpKDAIF Q}L," G -V www.mckim creed. com I I � I '�. .➢ I II II � \ Z EOP s. FT �17 P ��, — -- —� fs % OR \' / 1105 WA PLEA Y - - _- - __ -_ " �/ Rl�, 0 11t L12+00 LOC LOC 13+00 _ LOOS—�700..�� ayLO_ `_ (\ ( HA - �\ \_ _ + LOC -may-YM} •r --M L w -+—_- u N P{ I LOC .... .® _ ..... �.:c. - . . -^�'-- _ LOQ._.._. _LOC LOC _.. . 10Cr 10C..+�C_.. ... LOC _ 'R/WFr w > FT .. 1 -_.. LOti.—L _..LOS''. _. ._'fig♦ .._ - - - SILT FENCE SIDE -, r - -.> � NETLAND� R/'N TEMPORARY _ _ BEGIN PROPOSED 16" TEMPORARY _ - - - TEMPORARY TEMPORARY s wnrnE_ _ :, WATTLE - - SILT FENCE PVC C-905 _ I+�RANDS " r.A' 'I �- - - SILT FENCE WATER MAIN — � — £xisnNc R/w I STA FF 10+00 FIRE HYDRANT (TYP) I I SEE NC 211 CONNECTION PROPOSED 16" PVC ASSEMBLY MAINTAIN 10' HORIZONTAL PLAN VIEW I (SEE DETAIL OF SEPARATION BETWEEN E S77 i SHEET C-6 I C-905 WATER MAIN ON SHEET 1 OF 5) POWER POLES AND WATER MAIN ( WATER I II AT ALL TIMES (TYP) —20' PERMANENT EASEMENT 10+00 11+00 12+00 13+00 14+00 15+00 16+00 17+00 18+00 19+00 sEAt � v Mq BI& CREED eJ45wlcx SEA 243 North Front Street BRUNSWICK COUNTY '{ Wilmington, North Carolina 28401 NORTH CAROLINA Phone: (910)343-1048, Fax: (910)251-8282 r WM1.}!0 `y Lic— F-1222 TN C Ma��tx IICV.NG DE VISI ONSG✓'i, t. www.mckimcreed.com 60 40 30 20 20+00 21+00 22+00 23+00 24+00 50' 0 50' 100' 5' 0 5' 10' SCALE: 1"=50' (Horiz.) SCALE: 1"=5' (Vert.) DATE JUNE 2016 SCALE "� NA1Bw EF MIDDLETON SR 1105 MCE PROJ.I 00069 OOPS DRAWN yy HORIZONTAL• oy,,,K rAew WATER MAIN IMPROVEMENTS DESIGNED AWB ..,a. CHECKED AWB %ERTICAL Cj-1 16" WATER MAIN PROJ. MGR. AMB -5 PLAN AND PROFILE sTwTus: ISSUED FOR PFRMITMG « STA 10+00 TO STA 24+00 U — --� LLICZT — - wLLJ— __ o MAINTAIN �' H r p _—J�l--SfPAR-AION"BEIWEA i i �L + — = �\ POWER POLES AND ATER, '_ 29+� LOO— AT 5 jdNAT ALL TIM &+YI - - -- LOC N 2 LLO. " cry..... ._ - r, +. w wF - FIRE HYDRANT _C IO 00 LO _. -. _. ' --+- ASSEMBLY W _ ; z (SEE DETAIL W-1 ON SHEET 1 OF 5) J TEMPORARY WETLANDS D WATTLE - WETLANDS 5' INSIDE SILT FENCE Q RAW FIRE HYDRANT Z ASSEMBLY M 16"x6" TEE D 3 LIMITS 1+LDC L00 --LDC' Oc OD DO L 36 SILT FENCE ~ts y ED OC WLP+�� LQC ^LOC w EXIS77NG R/W 5' INSIDE PROPOSED 16" PVC �� RAW 16" BUTTERFLY C-905 WATER MAIN / VALVE / FIRE HYDRANT / ASSEMBLY (SEE DETAIL W-1 / ON SHEET 1 OF 5) 24+00 25+00 26+00 27+00 28+DO 29+00 30+00 31+00 32+00 33+00 34+00 sLL � v NnQM&CREED x SEAt`� OeJBRUNSWICK COUNTY 243 North Front Street }� _ Wilmington, North Carolina 28401 NORTH CAROLINA '' Il cf�'OP� Phone: (910)343-1048, Fax: (910)251-8282 N, ~ T y� LIcww F-1222 CPR B N 'N0t °E1pMS °Ah l www.mckimcreed.com REVISCINS n W 70 1 60 1 50 1 40 1 30 35+00 36+00 37+00 38+00 39+00 39+50 50' 0 50' 100' 5' 0 5' 10' SCALE: 1"=50' (Horiz.) SCALE: 1"=5' (Vert.) DATE JUNE 2016 SCALE we xlAeEv EF MIDDLETON SR 1105 MCEPRO., °°°69 Dom" HORIZONTAL' DRAWB JPy �� •x� WATER MAIN IMPROVEMENTS DESIGNED AWB I' -s' CHECKED AWS VERTICAL: C-2 16" WATER MAIN PROJ. MGR. AWB 1'-5' PLAN AND PROFILE STATUS STA 24+00 TO STA 39+50 ISSUED FOR PERMITTING ""N D - n r Z M D _ W O 00 U) LOC m _ m _ cf) m WETLANDS m T FENCE -i n W 70 1 60 1 50 1 40 1 30 35+00 36+00 37+00 38+00 39+00 39+50 50' 0 50' 100' 5' 0 5' 10' SCALE: 1"=50' (Horiz.) SCALE: 1"=5' (Vert.) DATE JUNE 2016 SCALE we xlAeEv EF MIDDLETON SR 1105 MCEPRO., °°°69 Dom" HORIZONTAL' DRAWB JPy �� •x� WATER MAIN IMPROVEMENTS DESIGNED AWB I' -s' CHECKED AWS VERTICAL: C-2 16" WATER MAIN PROJ. MGR. AWB 1'-5' PLAN AND PROFILE STATUS STA 24+00 TO STA 39+50 ISSUED FOR PERMITTING ""N N U w w (n w w (n CD rn M Q w z_ J U I- Q In 12" -90( FALLED BY 40+00 41+00 42+00 43+00 44+DO 45+00 46+00 47+00 48+00 49+00 MIOMV � p5M1tM c,, - -� BRUNSWICK COUNTY 243 Horth Front Street �c111rr Wilmington, on, North Carolina : (91 NORTH CAROLINA ?r ,� Phone: (910)343-1048, Fax: (910)251-8282 r W. Lkmx F -1z22 AEr.KG °EscRv°°"5 _ -- _ _ www.mckimereed.com REV D C7 r_ z M D cn cn CD CD in M M M M n a 70 l 60 1 SO 1 40 1 30 50+00 51+00 52+00 53+00 54+00 55+00 50' 0 50' 100' 5' 0 5' 10' SCALE: 1'=50' (Horiz.) SCALE: 1"=5' (Vert.) DATE JUNE 2018 SCALE wtru xlAeu EF MIDDLETON SR 1105 MCARRO. DRANK °°°6� DI" yy HORIZONTAL WATER MAIN IMPROVEMENTS DESIGNED ANS 1.'50. VERTICAL: C-3 16" WATER MAIN CHECKED ANS PRDJ. NIGR. Awa I. -S. PLAN AND PROFILE STA 39+50 TO STA 55+00 STATUS ISSUED FOR PERMInw LAI C) �^ 1 , EOP�� i LLJ LLJ A P (n LLJ W OCD -- - _ Lo Lo f— �•L.r • WL7LANDS U) W ExisnNc z 5' INSIDE GUARDRAIL R/W FIRE HYDRANT , = 1,996 LF 12" C-900 ASSEMBLY C-) FPVC INSTALLED BY (SEE DETAIL W-1 Y � DIRECTIONAL DRILL ON SHEET 1 OF 5) Q (SEE DETAIL WS -4 WETLAND ON SHEET 2 of 7)�,�• 5' OPF 10. 0FP RE-T4/A1/NC ALUMINUM — RETAINING WALL EXIS77NG R/W FENCE (TYP) \ wv R nEy ti / Sr ENO ALUMINUM RETAINING WALL \ \\`KE 7LANDS ` 5' INSIDE / R/W _ V GATE "ROPOSED 16" PVC -- - __ 640 LF -�FPVC INSTALLED BYTEMPO VALVE 5' .. AR--\ IRECTIO-A "\ �. WATTLE WATTLE � \\\\� � ..s� VALVE p OFF EOP 2" AUTOMATIC - DO­_—Z.LOc- - _` FLUSHING DEVICE (SEE DETAIL W-2 SHEET 1 OF 5) R nEy ti / Sr ENO ALUMINUM RETAINING WALL \ \\`KE 7LANDS ` M 55+00 56+00 57+00 58+00 59+00 60+00 61+00 62+00 63+00 64+00 60 50 40 —1 30 65+00 ` vNI�IQM£�CREED °+Sw1Cx BRUNSWICK COUNTY 243 North Front Street 1 Wilmington, North Carolina 26401 NORTH CAROLINA Phone: (910)343-1048, Fax: (910)251-8282 �'"'o,��NIY W•8y.t'O�` Elcmae: F-1222 ArNC Wad\ arra mw_DANREVISIONS v www.mckimcreed.com 50' 0 50' 100' 5' 0 5' 10' SCALE: 1"=50' (Horiz.) SCALE: 1'=5' (Vert.) EF MIDDLETON SR 1105 DATE: JUNE 2016 SCALE AND SEAFIELD DR MCE PROD. / D0069 aD43 DRAWN J" HORIZONTAL WATER MAIN IMPROVEMENTS DESIGNED AWB 1"-50• CHECKED AWB %'ERTICAL: C-4 PROJ. MCR. AWB 1'-5' 16" WATER MAIN PLAN AND PROFILE STATUS: ISSUED FOR PERMITT1Nc STA 55+00 TO STA 64+62 5' INSIDE / R/W _ V GATE "ROPOSED 16" PVC SILT FENCE VALVE 5' C-905 WATER MAIN EPIT MATCHLINE STA 64+62 SEE SHEET C-5 , • ' ; ; ,16" , , MJy PLUG ' W/2"TAP 16"x12" MJ TEE 16" BUTTERFLY VALVE • ' FIRE , ' ' , • ' ' ' , , ' HYDRANT , WE'RAND' 'ASSEMBLY ' • ' ' ' , • ' ' y , -(SEE DETAIL W-1 ' ' ' ' , , • ' i ON SHEET 1 OF 5) 70 M 55+00 56+00 57+00 58+00 59+00 60+00 61+00 62+00 63+00 64+00 60 50 40 —1 30 65+00 ` vNI�IQM£�CREED °+Sw1Cx BRUNSWICK COUNTY 243 North Front Street 1 Wilmington, North Carolina 26401 NORTH CAROLINA Phone: (910)343-1048, Fax: (910)251-8282 �'"'o,��NIY W•8y.t'O�` Elcmae: F-1222 ArNC Wad\ arra mw_DANREVISIONS v www.mckimcreed.com 50' 0 50' 100' 5' 0 5' 10' SCALE: 1"=50' (Horiz.) SCALE: 1'=5' (Vert.) EF MIDDLETON SR 1105 DATE: JUNE 2016 SCALE AND SEAFIELD DR MCE PROD. / D0069 aD43 DRAWN J" HORIZONTAL WATER MAIN IMPROVEMENTS DESIGNED AWB 1"-50• CHECKED AWB %'ERTICAL: C-4 PROJ. MCR. AWB 1'-5' 16" WATER MAIN PLAN AND PROFILE STATUS: ISSUED FOR PERMITT1Nc STA 55+00 TO STA 64+62 WATER t. STA 76 - PROPOSED 12" PVC C-900 WATER MAIN ► EXIS77NG FIRE ' HYDRANT I EXIS77NG 12 - WA TER 2"WATER MAIN TE SILT FENCE 5' INSIDEVALVE 78+00 R/W 75+00- - 74+00 - W_ — 72+00 _---- _ G 12" LOO . , LOC - LOC -LOC c _ - - - - - - VAL NSE HYDRANT LIMITS OF CLEARING ASSEMBLY _ - -_(SEE DETAIL W-1 _ ON SHEET 1 OF 5) REMOVE EXISTING PLUG/CAP I (OR BLOW -OFF ASSEMBLY) AND CONNECT NEW 12" WATER MAIN TO EXISTING 12" WATER MAIN I 30 I � BO __......._..... ....._I.._ ..... .._... L ..........................._ i 1 MATCHLINE STA 64+62 SEE SHEET C-4 I IALUMINUM ._... ........... CONSERVATION RETAINING WALL •I' EASEMENT END ALUMINUM 1 j AREA EXISTING R/W I RETAINING WALL ` . FENCE (TYP) 643 LF 12" C-900 . END ALUMINUMFPVC INSTALLED BY ;_I,.; DIRECTIONAL DRILL RETAINING WALLjw: (SEE DETAIL WS -4 1 " f c',IiI 5' OFF ON SHEET 2 of 7) .•""�� 1:, +.15'x15' -� RETAIWALL BORE PIT67+001 I F MATCHLI -�-- E STA 64+62 S Ei ECIP 77/ / VALVE $ (ASPHALT) WMANDS fo — i w I / CONSERVATIONS I " �.• ( EASEMENT � AREA I H RIZ TAL DIRECTIONAL DRILL (EE DETAIL 1 WATER t. STA 76 - PROPOSED 12" PVC C-900 WATER MAIN ► EXIS77NG FIRE ' HYDRANT I EXIS77NG 12 - WA TER 2"WATER MAIN TE SILT FENCE 5' INSIDEVALVE 78+00 R/W 75+00- - 74+00 - W_ — 72+00 _---- _ G 12" LOO . , LOC - LOC -LOC c _ - - - - - - VAL NSE HYDRANT LIMITS OF CLEARING ASSEMBLY _ - -_(SEE DETAIL W-1 _ ON SHEET 1 OF 5) REMOVE EXISTING PLUG/CAP I (OR BLOW -OFF ASSEMBLY) AND CONNECT NEW 12" WATER MAIN TO EXISTING 12" WATER MAIN I 30 BO __......._..... ....._I.._ ..... .._... L ..........................._ .__.......:_..—___.._._.. __._-._ _.—.__._......__... .....:......... ... ........ .._. — _... ....... ._. ..._. __ .__. ...... .... ._... ........... i ....... .. 1 : . I I ...............I. i I MATCHLI -�-- E STA 64+62 S Ei HEET C fo — i w I I I70 H RIZ TAL DIRECTIONAL DRILL (EE DETAIL -4 ON SHEET 2 V 7)I I fiEF M DLETON BLVDX157/ G E 571N I 1 IS71NG ' ll SR 1 OS A HAL 57/N 2" P E I EXISTING CM ; EXl57WG (PROC7ED ' GIPpI/ND 42' CMP 41" C;MP -- iARI i — ..i .. . �. i so y - MIN I _ so ---..__._.. 1.....__.._.. _._._ ._._..........._. _..........._._.................. ....__.._.__.......... _ } _ i __.. .. ..._. ..._—..�__. ............._....._ I ._.......... THEOREMCALI 1:1 i _. _....1._.. _._..__ ._ .._._. I ..._........... ........._.......__.__.._ " i ._...__. ._._.._._ .._.......... -- .... _.... i 50' MW ......... 0" M O.YE. ..... ._....-- -- ....... ._.. -COVER i :OVER i ... ........ .- -..._ ...... __.. ...... _...— - --- i .. ...... . - ...... ......- --- ...--- -......-------- ..:.... ---------- ---- --- - .... -- .�... ---------__i_.--h---- ...... .. I ; I COVE I i I 1 I I I i 1 .... - - ...._ —_•.._.VALVE - '-- - --'- I I i 50 50 i ASSEMBLY I 643 LF 12" C-900 I ! FPVC INSTALLED BY _ DIRECTIONAL DRILL i I 4040 ! I 64+00 65+013 66+DO 67+00 68+00 69+00 70+00 71+00 72+00 73+DO sru s.� 46 Nfj<VI� &CREED �� V - 243 North Front Street BRUNSWICK COUNTY Wilmington, North Carolina 26401 NORTH CAROLINA Phone: (910)343-1048. Fax: (910)251-8282 W.a i Lk-- F-1722 fNC pa Rrv.xo. ocxAPnws �ly tib www.mckimcreed.com R REMOVE EXISTING PLUG/CAP (OR BLOW -OFF ASSEMBLY) AND CONNECT NEW 12" WATER MAIN TO EXISTING 12" WATER MAIN 50' 0 50' 100' 5' 0 5' 10' SCALE: 1"=50' (Horiz.) SCALE: 1"=5' (Vert.) EF MIDDLETON SR 1105 DATE .TUNE 2016 SCALE PR AND SEAFIELD DR MCA OD °°°6� °°' DRAWN .PV HORIZONTAL .,,� •ueEn WATER MAIN IMPROVEMENTS DESIGNED AN9 1""50. CHECKED AWB VERTICAL: C-5 PROD. MGR. 12" WATER MAIN PLAN AND PROFILE 64+62 TO 76+27 sTATus: ISSUED FOR PERMITTING EXISTING 16"---� EXISTING 16" VALVE _ VALVE EXISTING 16 I EXISTING WATER MAIN I 16x12" REDUCER . — I � (SEE NOTE 1) �G\ I tI EXIS77NG 6" VALVE / EXISTING 12" VALVE / (SEE NOTE 7) / / NOTES: / 1. FITTINGS AND VALVES REMOVED AS PART OF THIS PROJECT SHALL BE RETURNED TO BRUNSWICK COUNTY P 4, EXISTING FIRE HYDRANT EXISTING CONDrI1ONS NC 2tI CONNECTION PLAN VIEW I"= 10' 3' MIN COVER NEW 16" BUTTERFLY VALVE NEW 20 LF 16" DI NEW 16"x16" MJ DI TEE NOTES: AT HIS DISCRETION, CONTRACTOR MAY UTILIZE FOSTER ADAPTERS (OR APPROVED EOUAL) FOR THIS CONNECTION TO MINIMIZE LAY LENGTH AND WORK AREA J m LL NEW 16"x12" MJ REDUCER EXISTING 16" WATER MAIN I 3'I�MAXIMUM LIMIT I OF CONSTRUCTION SEE NOTE 1 PROPOSED IMPROVEMENTS NC 01 CONNECTION PLAN VIEW I" = 10 EXISTING ASPHALT NC 211/EF MIDDLETON TURN RADIUS 3' MIN COVER I THEORETICAL I SLOPE -------------- -------- --1 -------- f ------------ -----------v EXIS77NG 12" NEW 12" GATE VALVE WATER MAIN NC 211 CONNECTION SECTION I" - 20 N ........ tN �ssl `v%NFQM&CREED EF IDDi ETON SR 1105 t CBRUNSWICK COUNTY WATER N IMPROVEMENTS 1 243 North Front Street Wilmington, North Carolina 28401 NORTH CAROLINA (ji, `�flltii� p° Phone: (910)343-1048, Fax: (910)251-8282 - NC 211 CONNECTION DETAILS 'y 1 W; °� License: F-1222 "rx c W0�`' REv wO OE REVISIONS S www. mckim creed. com 1 NOTES, 1. CONTRACTOR SHALL MAINTAIN LIMIT OF EXCAVATION TO MAXIMUM 5'OFF EDGE OF PAVEMENT AND OUTSIDE OF A 1:1 SLOPE FROM EDGE OF PAVEMENT SEE DETAILS THIS SHEET DATE: JUNE 2016 SCALE �� nlE xuua RICE PROJ. p 00069-0043 DRAWN NEW 16"x12" MJ REDUCER EXISTING 16" WATER MAIN I 3'I�MAXIMUM LIMIT I OF CONSTRUCTION SEE NOTE 1 PROPOSED IMPROVEMENTS NC 01 CONNECTION PLAN VIEW I" = 10 EXISTING ASPHALT NC 211/EF MIDDLETON TURN RADIUS 3' MIN COVER I THEORETICAL I SLOPE -------------- -------- --1 -------- f ------------ -----------v EXIS77NG 12" NEW 12" GATE VALVE WATER MAIN NC 211 CONNECTION SECTION I" - 20 N ........ tN �ssl `v%NFQM&CREED EF IDDi ETON SR 1105 t CBRUNSWICK COUNTY WATER N IMPROVEMENTS 1 243 North Front Street Wilmington, North Carolina 28401 NORTH CAROLINA (ji, `�flltii� p° Phone: (910)343-1048, Fax: (910)251-8282 - NC 211 CONNECTION DETAILS 'y 1 W; °� License: F-1222 "rx c W0�`' REv wO OE REVISIONS S www. mckim creed. com 1 NOTES, 1. CONTRACTOR SHALL MAINTAIN LIMIT OF EXCAVATION TO MAXIMUM 5'OFF EDGE OF PAVEMENT AND OUTSIDE OF A 1:1 SLOPE FROM EDGE OF PAVEMENT SEE DETAILS THIS SHEET DATE: JUNE 2016 SCALE �� nlE xuua RICE PROJ. p 00069-0043 DRAWN JPV HORIZONTAL pn.�wxc xuuav DESIGNED AWB AS SHOWN CHECKED AWB VERTICAL. C-6 PROD. MGR. AWB NA sTATus: ISSUED FOR PERMITTING A. BURY THE TOP END OF THE UNER STRIPS IN A TRENCH 4 INCHES OR MORE IN DEPTH. B. TAMP THE TRENCH FULL OF SOIL. TAMPED BACKFILL SECURE WITH A ROW OF STAPLES, 10 INCH SPACING, 41NCHES DEWATERING DOWN FROM TRENCH I TALL FESCUE C. OVERLAP - BURY UPPER END OF LOWER "B". 2:1 SLOPE. GRAVEL FILTER STRIP AS IN A" AND OVERLAP END OF TOP STRIP 4 INCHES AND STAPLE. , \ TAMPED BACKFILL _-_=_-_-_-=__=- D. EROSION STOP - FOLD OF LINER BURIED IN DOUBLE ROW SILT TRENCH AND OF STAPLES TAMPED. DOUBLE ROW OF STAPLES. NOTE: INSTALL TACKED MULCH IN EXISTING DITCHES AT AREAS -WHERE DITCH IS DISTURBED UNLESS OTHERWISE NOTED. TBuPORARY LNERS NOT TO SCALE JUTE NET OR STRAW WITH NET 2 INCH OVERLAP OF LINER STRIPS WERE TWO OR MORE STRIP WIDTHS ARE REQUIRED. STAPLES ON 3' TO 4' CENTERS. PLACE STAPLES 4 TO 10 FEET APART. TYPICAL STAPLES NO. 8 GAUGE WIRE NOTES -WARNING SIGNS TO BE MADE OF DURABLE. WEATHERPROOF MATERIAL -LETTERS TO BE 3" HT. MIN., CLEARLY LEGIBLE AND SPACED AS DETAILED. -ATTACH SIGNS SECURELY TO FENCE POSTS AND FABRIC. ii'• PAIII 1A I i=I A =1 k a NOT TO SCALECONCRETE BLOCK TYPE DEWATERING AUG. 15 - NOV. 1 TALL FESCUE 300 LBS/ACRE 2:1 SLOPE. GRAVEL FILTER CONSTRUCTION SPECIFICATIONS f� (MAR. JUN. 30)OR h ABRUZZI RYE 25 LBS/ACRE MAR. 1 - APR. 15 TALL FESCUE 300 LBS/ACRE APR. 15 - JUN. 30 1. LAY ONE BLOCK S EACH SIDE OF THE ON ITS SIDE ON THE ROW TO _ .AIL. 1 - AUG. 15 DATION ALLOW PO ALLOW POOL DRAINAGE. THE FOUNDATION SHOULD 120 LBS/ACRE SEP. 1 - MAR. 1 BE EXCAVATED AT LEAST 2 INCH BELOW THE 35 LBS/ACRE CREST OF THE STORM DRAIN. PLACE THE BOTTOM D(I5TINC CURB EXISTING CURB ROW OF THE BLOCK AGAINST THE EDGE OF THE 25 LBS/ACRE INLET AND GRATE STORM DRAIN FOR LATERAL SUPPORT AND TO AVOID WASHOUTS WHEN OVERFLOW OCCURS. IF NEEDED, GIVE LATERAL SUPPORT TO SUBSEQUENT WIRE SCREEN ROWS BY PLACING 2,4 WOOD SUDS THROUGH TEMPORARY BLOCK OPENINGS. SEDIMENT POOL DEWATERING 2. CAREFULLY FITI HARDWARE CLOTH COMPARABLE W WIRE MESH ml 1/2 -INCH OPENING OVER ALL _ _ BLOCK OPENING TO HOLD GRAVEL IN PUCE. 1' MIN. 16 3. USE CLEAN GRAVEL 3/4 -TO 1/2 -INCH IN 2 MAX. DIAMETER, PLACED 2 INCHES BELOW THE TOP OF THE BLOCK ON A 2:1 SLOPE OR FLATTER AND SMOOTH IT TO AN EVEN GRADE DOT /57 WASHED STONE IS RECOMMENDED SEDIMENT GRAVM FILTER UJ7= PROTECTION NOT TO SCALE SEEDING SCHEDULE FOR STABILIZATION GRASS SHOULDERS, SIDE DITCHES, SLOPES (MAX. 3:1 DATE TYPE PLANTING RATE AUG. 15 - NOV. 1 TALL FESCUE 300 LBS/ACRE NOV. 1 - MAR. 1 TALL FESCUE 300 LBS/ACRE (MAR. JUN. 30)OR h ABRUZZI RYE 25 LBS/ACRE MAR. 1 - APR. 15 TALL FESCUE 300 LBS/ACRE APR. 15 - JUN. 30 HULLED COMMON BERMUDA GRASS 25 LBS/ACRE .AIL. 1 - AUG. 15 TALL FESCUE AND 120 LBS/ACRE SEP. 1 - MAR. 1 •' BROWNTOP MILLET 35 LBS/ACRE ••• OR SORGHUM - SUDAN HYBRIDS 30 LBS/ACRE SHOULDERS, SIDE DITCHES, SLOPES (3:1 TO 2:1) MAR. 1 - JUN. 1 SERICEA LESPEDEZA (SCARIFIED) 50 LBS/ACRE (MAR. 1 - APR. 15) ADD TALL FESCUE 120 LBS/ACRE (MAR. 1 - JUN. 30 OR ADD WEEPING LOVERGRASS 10 LBS/ACRE (MAR. JUN. 30)OR ADD HULLED COMMON BERMUDA GRASS 25 LBS/ACRE JUN. 1 - SEP. 1 •r• TALL FESCUE AND 120 LBS/ACRE ••• BROWNTOP MILLET 35 LBS/ACRE ••• OR SORGHUM - SUDAN HYBRIDS 30 LBS/ACRE SEP. 1 - MAR. 1 SERICEA LESPEDEZA (UNHULLED - UNSCARIFIED) 70 LBS/ACRE AND TALL FESCUE 120 LBS/ACRE NOV. i - MAR. 1 ADD ABRUZZI RYE 25 LBS/ACRE CONSULT CONSERVATION ENGINEER OR SOIL CONSERVATION SERVICE FOR ADDITIONAL IN- FORMATION CONCERNING OTHER ALTERNATIVES FOR VEGETATION OF DENUDED AREAS. THE ABOVE VEGETATION RATES ARE THOSE WHICH DO WELL UNDER LOCAL CONDITIONS, OTHER SEEDING RATE COMBINATIONS ARE POSSIBLE. • TEMPORARY -- RESEED ACCORDING TO OPTIMUM SEASON FOR DESIRED PERMANENT VEGETATION. DO NOT ALLOW TEMPORARY COVER TO GROW OVER 12" IN HEIGHT BEFORE MOWING,OTHERWISE FESCUE MAY BE SHADED OUT. 1. CHISEL COMPACTED AREAS AND SPREAD TOPSOIL 3 INCHES DEEP OVER ADVERSE SOIL CONDITIONS, IF AVAILABLE. 2. RIP THE ENTRE AREA TO 6 INCHES DEPTH. 3. REMOVE ALL LOOSE ROCK, ROOTS, AND OTHER OBSTRUCTIONS LEAVING SURFACE REASONABLY SMOOTH AND UNIFORM. 4. APPLY AGRICULTURAL UME, FERTILIZER, AND SUPERPHOSPHATE UNIFORMLY AND MIX WITH SOIL (SEE BELOW). 5. CONTINUE TILLAGE UNTIL A WELL - PULVERIZED, FIRM, REASONABLY UNIFORM SEEDBED IS PREPARED 4 TO 6 INCHES DEEP. 6. SEED ON A FRESHLY PREPARED SEEDBED AND COVER SEED LIGHTLY WITH SEEDING EQUIPMENT OR CULTIPACK AFTER SEEDING. 7. MULCH IMMEDIATELY AFTER SEEDING AND ANCHOR MULCH. 8. INSPECT ALL SEEDED AREAS AND MAKE NECESSARY REPAIRS OR RESEEOINGS WITHIN THE PLANTING SEASON, IF POSSIBLE. IF STAND SHOULD BE OVER 607. DAMAGED REESTABUSHED FOLLOWING ORIGINAL UME. FERTIUZER AND SEEDING RATES. 9. CONSULT CONSERVATION INSPECTOR ON MAINTENANCE TREATMENT AND FERTILIZATION AFTER PERMANENT COVER IS ESTABLISHED. • APPLY. AGRICULTURAL LIMESTONE - 2 TONS/ACRE OR 3 TONS/ACRE IN CLAY SOILS FERTILIZER - 1000 LBS/ACRE (10-10-10) SUPERPHOSPHATE - 500 LBS/ACRE (20x) MULCH - 2 TONS/ACRE (SMALL GRAIN STRAW) ANCHOR - ASPHALT EMULSION AT 450 GAL/ACRE ULTRAVIOLET RESISTANT GEOTEXTILE FABRIC OR EQUIVALENT p7 WRE TO WIRE W/METAL CENTER. CUCPS RE AT 8" ON CENTER. 2' 6" IB" 12 GUAGE 4 x 4 OR 2 x 4 WELDED WIRE HOOKED INTO PREFORMED MAX SEDIMENT STORAGE LEVELS 1/2 HEIGHT. REMOVE SEDIMENT MEN THIS LEVEL IS REACHED OR AS DIRECTED BY THE PROJECT INSPECTOR. SHEET DRAINAGE ONLY. . NATURAL GRADE^- COIR FIBI CARRY 12 INCHES OF FABRIC TRENCH COVER W/ SOI NDT MP L CARRY 6" OF WRE INTO TRENCH. METAL POSTS AT e' O.C. MAX SILT FENCES SHOULD NOT BE USED AT PIPE OUTLETS OR IN AREAS OF CONCENTRATED FLOWS (CREEKS, DITCHUNES. SWALES ETC.). SLOPE \` SOMEfM VIEW NOTES: USE MINIMUM 12 IN. DIAMETER COIR FIBER (COCONUT FIBER) WATTLE USE 2 FT. WOODEN STAKES WITH A 2 IN. BY 2 IN. NOMINAL CROSS SECTION. ONLY INSTALL WATTLE(S) TO A HEIGHT IN DITCH SO FLOW WILL NOT WASH AROUND WATTLE AND SCOUR DITCH SLOPES AND AS DIRECTED. INSTALL A MINIMUM OF 2 UPSLOPE STAKES AND 4 DOWNSLOPE OF PAVEMENT STAKES AT AN ANGLE TO WEDGE WATTLE TO BOTTOM OF DITCH. PROVIDE STAPLES MADE OF 0.125 IN. DIAMETER STEEL WIRE FORMED INTO A U SHAPE NOT LESS THAN 12" IN LENGTH. INSTALL STAPLES APPROXIMATELY EVERY 1 UNEAR FOOT ON BOT, SIDES OF WATTLE AND AT EACH END TO SECURE IT TO THE SOIL INSTALL MATTING IN ACCORDANCE WITH SECTION 1631 OF THE STANDARD SPECIFICATIONS 2'(MAX.) 2' UPSLOPE STAKE IATURAL GROUND MATTING 2' DOWNSLOPE STAKE CfKM SECTION VEE DITCH 2 IN. --;?,,7 ROW UPSLOPE STAKE NATURAL GROUND MATTING DOWNSLOP S E STAKE CROSS SECTION THAPUMAL DECH -GATHER EXCESS AT CORNERS d �bl 7�STAKEI STAPLE INSET A INSET B COIR F IM WATTLE DEMI. NOT TO SCALE #57 WASHED STONE rwcInl rv�i \` 2' 16" MIN. -I I II I II I I- �-III-I I -I5' MIN. ,' MIN. BURIED WRE FABRIC I I� T Li CONSTRUCTION SPECIFICATIONS 1. UNIFORMLY GRADE A SHALLOW DEPRESSION APPROACHING THE INLET. 2. DRIVE 5 -FOOT STEEL POSTS 2 FEET INTO THE GROUND SURROUNDING THE INLET. SPACE POSTS EVENLY AROUND THE PERIMETER OF THE INLET, A MAXIMUM OF 4 FEET APART. 3. SURROUND THE POSTS WITH WIRE MESH HARDWARE CLOTH. SECURE THE MARE MESH TO THE STEEL POSTS AT THE TOP, MIDDLE, AND BOTTOM. PLACING A 2 -FOOT MP OF THE WIRE MESH UNDER THE GRAVEL FOR ANCHORING IS RECOMMENDED. 4. PLACE CIFM GRAVEL (NC DOT /5 OR #57 STONE) ON A 2:1 SLOPE WITH A HEIGHT OF 16 INCHES AROUND THE WIRE, AND SMOOTH TO AN EVEN GRADE. 5. ONCE THE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED, REMOVE ACCUMULATED SEDIMENT, AND ESTA13USH FINAL GRADING ELEVATIONS. 6. COMPACT THE AREA PROPERLY AND STABILIZED IT MATH GROUNDCOVER. SLT FENCE DETAIL WLET PROTECTION (STAGE ONE) NOT TO SCALE NOT TO SCALE TOP VIEW REFERENCE DETAIL BELOW ti T 6" GRAVEL FILTER MIN OR FILTER CLOTH 1.5 T MIN THE DIAMETER OF THE LARGEST STONE SHALL NOT EXCEED 1.5 TIMES THE SIZE OF THE RIP -RAP. (EX. 12" FOR 8") MINIMUM THICKNESS (T) SHOULD BE 1.5 TIMES THE MAXIMUM STONE DIAMETER. BUT IN NO CASE LESS THAN 6". 1. EACH RIP RAP PLACEMENT SHALL BE BEDDED IN EITHER A 6 INCH LAYER OF STABILIZATION STONE OR A TYPE II NON -BIODEGRADABLE FILTER FABRIC. PLACEMENT OF RIP -RAP SHALL IMMEDIATELY FOLLOY THE PLACEMENT OF THIS LAYER. KEEP VOIDS TO A MINIMUM AND FORM A DENSE WELL GRADED MASS OF STONE. DO NOT DISLODGE THE UNDERLYING BASE OF FILTER WHEN PLACING STONE. COST OF THE STONE BASE OR FILTER SHALL BE INCLUDED IN THE COST OF THE PLACING OF RIP -RAP. 2. MAXIMUM STONE SIZE WHEN USING 8 INCH 050 WILL BE 12 INCHES AND THE MINIMUM THICKNESS OF THE RIP -RAP LAYER SHALL BE 18 INCHES. 3. MAXIMUM SLOPE OF THE CHANNEL BANK SHALL NOT EXCEED 2.0 HORIZONTAL TO 1.0 VERTICAL FINISHED GRADE OF THE RIP -RAP IS TO BLEND WITH THE SURROUNDING AREA. 4. INSPECT RIP -RAP PERIODICALLY FOR SCOUR OR DISLODGED STONES (ESPECIALLY AFTER SEVERE STORMS) AND WEED BRUSH GROWTH. RP RAP PLAC 145U DETAIL NOT TO SCALE CONSTRUCTION SEQUENCE 1. INSTALL TEMPORARY SILT FENCING, CHECK DAMS, OR OTHER MEASURES AS SHOWN ON THE APPROVED PLANS, AND AS NOTED IN TECHNICAL SPECIFICATION SECTION 022410. ?Vev 4L USE -3" WASHED STONE, \ 6" THICK, 12' WIDE (MIN), p 50' LONG (MIN) '2 " MIN (2)-3" COARSE AGGREGRATE TEMPORARY GRAVEL CONSTRUCTION ENTRANCE NOT TO SCALE 2. INSTALL TEMPORARY GRAVEL CONSTRUCTION ENTRANCE WHERE REQUIRED TO ACCESS WORK AREA. 3. PROTECT INLETS WITH SILT FENCING, SEDIMENT TRAPS OR OTHER APPROVED MEASURES AS SHOWN ON THE PLANS, AND AS NOTED IN TECHNICAL SPECIFICATION SECTION 022410. 4. CALL FOR ONSITE INSPECTION BY ENVIRONMENTAL INSPECTOR AND OBTAIN CERTIFICATION OF COMPLIANCE, PRIOR TO CONSTRUCTION IN EACH AREA. 5. OPEN TRENCH, INSTALL PIPELINE. AND BACKFILL TRENCH. 6. STABILIZE SITE AS TRENCH IS RESTORED TO ORIGINAL GRADE WITH VEGETATION, PAVING, DITCH UNINGS, ETC., AS NOTED IN TECHNICAL SPECIFICATION SECTIONS 022480, 022410, AND 022200. 7. WHEN VEGETATION HAS BECOME ESTABUSHED, AS NOTED IN TECHNICAL SPECIFICATION SECTION 022410, CALL FOR FINAL SITE INSPECTION BY ENVIRONMENTAL INSPECTOR. B. REMOVE SILT FENCING & CHECK DAMS AFTER FINAL APPROVAL FROM ENVIRONMENTAL INSPECTOR. YlG ilE xuAlEx DATE: JUNE 2016 SCALE �`•Nk DRAWN OJ.J 00069-0�4V HORIZONTAL puxNG xNIAFR EF MIDDLETON SR 1105MCK 'I BRUNSWICK COUNTY WATER MAIN IMPROVEMENTS �`.R DESIGNED AWB N/A .�- c 243 North Front Street CHECKED AWB VERTICAL D-1 Wilmington, North Carolina 28401 NORTH CAROLINA PROJ. MGR. AWB N/A P6monxe: E(1222 43-1048, Fax: (910)251-8282 N - EROSION CONTROL DETAILS srATus: ISSUED FOR PERMITTING www.mckimcreed.com 1. ALL OTAD END LINES WALL HAVE FLUSHING DEVICE. 2. MAINS 6" D LARGER SHALL USE A FIRE HYDRANT F A FLUSHING DEVICE. 3. FLUSHING HYD T COLOR SHALL BE "RED" ENAMEL PAINT. 4. POST HYDRANT SH HAVE 1 1/2-WCH PEN"FAGONAL OPERA NUT. 5. AT DISCRETION OF BRU ' CK COUNTY, AN AUTOMATIC FLUSHING DE (KUPFERLE 9400 £CUPSE) MAY BE REQUIRED UEU OF STANDARD MANUAL FLUSHING ANT (SEE DETAIL THIS SHEET) SMALLER MAN 6" STANDARD VALVE BOX WITH UO MARKED 'WATER" BRICK SUPPORT 00`/ / 2" IRON BRONZE MOJ GATE VALVE BRASS OR PYC NIPPLE 2" X 12' MECHANICAL JOINT OR MEGA -LUG TAPPED END CAP RODDED BACK TO THRUST! WITH STAINLESS STEEL RODS AND FASTENERS STANDARD FLUSHING DEVICE FOR MAINS LESS THAN 6" DETAIL W-3 FLUSHING HYDRANT - KUPFERLE ECLIPSE p2 ?OST HYDRANT (OR APPROVED EQUAL) BRICK SUPPORT 3/4" ALL -THREAD STAINFESI STEEL TIE _ ROD (CUT TO LENGTH) F— CR MEGA -LUG NOTES: 1. CONCRETE SH ' NOT CONTACT BOLTS OR EN OF MECHANICAL FITTINGS. 2. ALL TIE RODS AND NUTS TO BE STAINLESS STEEL, 3. LENGTH OF PIPESHALL BE MINIMUM NEEDED TO INSTALL FITTINGS. VALVE SHALL BE BOLTED DIRECTLY TO TEE WHENEVER POISSIBLE, ROD REQUIREMENTS BRANCH SIZE NO. OF RODS KUPFERLE 9400 ECLIPSE AUTOMATIC FLUSHING DEVICE 2 EA. 8" 2 EA. 6" 4 EA. WITH UV RESISTANT COVER - AT DISCRETION OF 4 EA. 16" NOTES: 20" 6 EA. BRUNSWICK COUNTY. CLOVER MUST LOCK 6 EA. LOCKING HASP 1L �• �A%I WATER OJTLETS 1. ALL DEAD END LINES WILL HAVE FLUSHING DEVICES, NOTES: 1. LOCKED HYDRANT & LOCKED HYDRANT ADAPTER OR MUELLER "AOUAGRIP' 1/2" PLASTIC UV RESISTANT VALVE BOX NTH UD 24 GROUND PLA'E' SO MARKED "WATER' 2. MAINS 6' AND GREATER NOT BEING EXTENDED IN THE FUTURE SHALL USE A FIRE HYDRANT FOR A FUJSHNG SYSTEM MAY BE USED IN PLACE OF RESTRAINT RODS. VARIES , OEVIC 2. VERTICAL MUELLER AWIA GRIP FRE HYDRANT SHOE MAY BE USED WHERE MAIN DEPTH IS GREATER THAN FEET, a /\ \/\ \\� \//\//\/\�\//\�\//\//\/\// I,�.:., :.: /\,\ \//\�\//\/ 3' DEVICEAFORM N EXTENSIONS 4ANDMDnUVERUAUTOMATIC / FWSHMG DEVICE TO BRUNSWICK COUNTY 3. USE SWIVEL HYDRANT TEE NTH 6" GATE VALVE DIRECTLY COUPLED TO PUMPER NOZZLE FACE \ \ 24" CONCRETE VALVE REPRESENTATIVE. HYDRANT TEE UNLESS OTHERWISE APPROVED BY BRUNSYIICK COUNTY TO STREET AT 90' / COLLAR, FLUSH WITH GRADE 4. FIRE HYDRANT COLOR SHALL BE "CHROME YELLOW" ENAMEL PAINT. w j� 5. FIRE HYDRANTS INSTALLED WITHIN THE NCDOT RIGHT-OF-WAY MUST BE CHAIN REVD INSTALLED WITHIN 12 -INCHES Of THE R/W LINE. LID 24' CONCRETE VALVE COLLAR z •---BRICK SUPPORT (TYP.) (FLUSH W/GRADE) 'WATER' SIDEWALKDISTA [MARKED m _ NCE VARIES _ Ju— _.__ .._ .{ ROAD CURB 6" 2' BRASS OR PVC � `:. •: A_ •. • \\� :_ .._/\ //\/ /---ORTMECA-LUG (TYP.jECT BOLTED INrR FLANGE, /\\/\\�: I // \�/�\ AWA GRIP FIRE HYDRANT SHOE, SEE [ NOTE 2 ) - 1/2 CU YD ~ VALVE BOX CRUSHED STONE TANGENTIAL DISCHARGE TEE W/ 6' 6" GATE FOR HYDRANT DRAINAGE BRANCH VALVE CONC THRUST BLOCK \— BEARING AGAINST 4 SO 2" THREADED 90' BEND WATER MAIN �GF•TE VALVE L o" AND LARGER THRUST \��.., FT UNDISTURBED «�q MATERIAL BRASS OR PVC M.J. CAP TAPPED 2" \ NO ACTIVE SERVICES SHALL BE INSTALLED BLOCK' �� (SEE CONCRETE \ BETWEEN THE VALVE AND THE BLOWOFF. •.. THRUST BLOCK SCHEDULE) \ �— 3/4" ALL -THREAD STAINLESS STEEL ROO // .. 6"m DIP PIPE .. FILL CONCRETE AND FASTENERS (CUT TO LENGTHOR \� f _h .. _� _ MEGA -LUG AUTOMATIC FLUSHING DE��ICE FOR MAINS 6" AND r-° MIN LARGER (FOR hfAINS TO BE EXTENDED LATER) PROVIDE 4-3/4"0 STAINLESS STEEL TIE RODS VALVE SUPPORT THREADED AT ENDS (INC. NUTS) ENCED DETAIL W-2 EQUALLY SPAA AROUND PIPE P BETWEEN ALL MECHANICAL NOTE: WEEP HOLES ARE JOINT FITTINGS (TEE, VALVE, BEND) TO BE FULLY FUNCTIONAL OR MEGA -LUG FIRE HYDRANT DETAIL W-1 (DEVIATION FROM STANDARD DETAIL) 1. ALL OTAD END LINES WALL HAVE FLUSHING DEVICE. 2. MAINS 6" D LARGER SHALL USE A FIRE HYDRANT F A FLUSHING DEVICE. 3. FLUSHING HYD T COLOR SHALL BE "RED" ENAMEL PAINT. 4. POST HYDRANT SH HAVE 1 1/2-WCH PEN"FAGONAL OPERA NUT. 5. AT DISCRETION OF BRU ' CK COUNTY, AN AUTOMATIC FLUSHING DE (KUPFERLE 9400 £CUPSE) MAY BE REQUIRED UEU OF STANDARD MANUAL FLUSHING ANT (SEE DETAIL THIS SHEET) SMALLER MAN 6" STANDARD VALVE BOX WITH UO MARKED 'WATER" BRICK SUPPORT 00`/ / 2" IRON BRONZE MOJ GATE VALVE BRASS OR PYC NIPPLE 2" X 12' MECHANICAL JOINT OR MEGA -LUG TAPPED END CAP RODDED BACK TO THRUST! WITH STAINLESS STEEL RODS AND FASTENERS STANDARD FLUSHING DEVICE FOR MAINS LESS THAN 6" DETAIL W-3 FLUSHING HYDRANT - KUPFERLE ECLIPSE p2 ?OST HYDRANT (OR APPROVED EQUAL) BRICK SUPPORT 3/4" ALL -THREAD STAINFESI STEEL TIE _ ROD (CUT TO LENGTH) F— CR MEGA -LUG NOTES: 1. CONCRETE SH ' NOT CONTACT BOLTS OR EN OF MECHANICAL FITTINGS. 2. ALL TIE RODS AND NUTS TO BE STAINLESS STEEL, 3. LENGTH OF PIPESHALL BE MINIMUM NEEDED TO INSTALL FITTINGS. VALVE SHALL BE BOLTED DIRECTLY TO TEE WHENEVER POISSIBLE, ROD REQUIREMENTS BRANCH SIZE NO. OF RODS 4" 2 EA. 8" 2 EA. 6" 4 EA. 12" 4 EA. 16" 6 EA. 20" 6 EA. 24" 6 EA. GATE VALVE THRUST BLOCK ^. °. •. II � I.. I I I DETAIL W-4 LA A is' MIN 5. PLAN VIEW 6' MIN /3 DOWELS O 12" ALL SIDES INFORCE #4 3/4- 3/4" CHAMFER (TYP` -.--A� OF B' E.W. SEE NOTE 3 -" _ .,...... ' . .W. ALL SIDE VALVE BOX /•, 6' MIN. 2' CL � +4• Y!!l. ,(\ .WAT MARKE \ C' (�\\ 4�'\�7/ rl�\i1 'WATER' 12' uiN. / \ r 12 MINI, BRICK SIIPPOR -- : /\\ ITT ) 12 MIN • •, 4- MIN. ALL SIDES s xs s/s O.CM DOw LS O 12 O c 2• CL uIN STONE BASE R QUIR_C FOR PRECAST DRAIN TO DITCH, STOPM UEPENDLNT CN SVBGRADE FOR CAST N PLACE CULVERT. CR SUMP PUMP. SECTION VIFW WATER METER VAULTS (Y TO 10" DETAIL W-8 NOTES: 1. THE BACKFLOW PREVENTION DEVICE MUST BE INSTALLED IN AN ACCESSIBLE LOCATION TO FACILITATE PERIODIC FIELD TESTING AND MAINTENANCE. 2. THE LOCATION SELECTED SHOULD HAVE ADEQUATE DPAINAGE FCR RELIEF VALVE DISCHARGE. DRAINAGE MAY BE PIPED AAAY. PROV,OING AN APPROVED AIR GAP DEVICE IS USED. THE DEVICE SHALL NOT BE PLACED WHERE IT MAY BECOME SUBMERGED IN STANDING WATER. 3. INSTALL THE DEVICE IN A HORIZONTAL POSITION MTN ADE(AJATE CLEARANCE FROM WALLS AND/OR OBSTRUCTIONS, FOR TESTING AND MAINTENANCE. A 12" TO 30" CLEARANCE BETWEEN THE LOWER MOST PORTION OF THE DEVICE AND ROOD GRADE OR FLOOR SHALL BE PROVIDED. 4. A 'Y STRAINER MAY BE INSTALLED JUST UPSTREAM OF THE BACKROW PREVENTION ASSEMBLY TO EUMINATE ANY DEBRIS FROM ENTERING THE DEVICE AND FOULING THE CHECK AND/OR RELIEF VALVE. 5. NO UNDERGROUND INSTALLATIONS ALLOWED. PROVIDE POSITIVE DRAINAGE XPIPINGSHALL CTION NOTES: ETE SHALL 4,000 PSI MIN. COMPRESSIVE GTH AT 2 AYS. ORCING S SHALL BE GRADE 60 DEFORMED STEEL. S SH BE APPROVED BY BRUNSWICK COUNTY. MOUNTED STEPS ARE NOT ACCESSIBLE FROM PERMANENTLY MOUNTED LADDER MEETING O.S.H.A. ARDS SHALL BE PROVIDED. ATE REINFORCEMENT AROUND HATCH TO PROVIDE ALENT STEEL CROSS-SECTION. IPING SHALL BE DUCTILE IRON. MIN. VAULT DIMENSIONS METER A B C SIZE 3' B'-6' S'-6' 5'-0' 4' 9'-6' S'-6' 5'-0' 6' 11"-0' 6'-0' 5-6' B' 12'-0' Y-0' 6'-0" 10' 14'-0" 8'-0" 6'-0' 10 AWWA C701 TURBINE METER OR AWWA C702 COMPOUND METER w/ENCODING REGISTER FOR REMOTE READING (SENSUS OR APPROVED EQUAL) METER MUST BE SUBMITTED FOR REVIEW AND APPROVAL BY BRUNSWICK COUNTY ENGINEER STRAINER BY METER MANUFACTURER. 3 AS DETERMINED BY BRUNSWICK COUNTY, AWWA C508 SWING CHECK VALVE WITH LEVER, do WEIGHT. OR SPRING, OR FLOMATIC MODEL 848/895 SPLIT DISC IS AWWA C509 GATE VALVE w/H.AND WHEEL AMP, ITRON SOW -2 PIT ERT WITH COMPATIBLE REGISTER. OR IVALFNT-MUS' BE APPROVED BY BRUNSWICK COUNTY V S! OR COUBLE LEAF A.UMINJM HATCH GRA` i DP.A.IN !O DA"LIGHT OR SUMP PUMP WITH FORCE MAIN TO CRA? ORA.NAGE 8� 'WATERTIGH SKET w/—ERAUL'C CEMENT SEAL 9• SOLD MASON. IFR FIXTURE SUPPORTS STEPS SFACEO AIROL6 O.C. l} IN --INE TEE OR TA G SLEEVE ./VALVE AND BOX TO GRADE WITH LID MARK "WATER" �I. ALL WATER METFR VAi)I TS%ST BE SIiBMITTFD TO BRUNSWICK ^OUNTY EN DEPARTMENT AS A SHOP SUBMITTAL FOR REVIEW AND AP VAL �. METER VAULT LID SHALL REST ON O% VAULT WALLS - NO JOINTS ARE ALLOWED 'N VAULT W - VAULT BOTTOM AND SIDES MAY BE PRECAST BUT TOP L BE PLACED ON TOP OF WALLS. INSULATED ENCLOSURE - 'HOT ROK" OR SIMILAR (E%TEP,IOR INSTALLATIONS ONLY) PROVIDE ADEQUATE HEIGHT OF ENCLOSURE TO ENSURE A 12" HEIGHT FROM RPZ TO EXISTING GROUND DRAINAGE POINT PROVIDE POSITIVE DRAINAGE VALVE BOX W/LTA MARKED- "WATER- (T...) BRICK SUPPORT- (TYP ) KING DIMENSIONS A B C 4' - 0" jT0 2' - 6' 1' - 6" 5' - 0" 4' - 0' 2' - 0' 8'-0" 6'-0" 3'-0' UNDISTURBED SOIL BACKFILL N11. i CONIC. BLOCKING i; �� ISI—I =111� • I I—III B II�IIF VI— II i1- I �I I I I I I' \ UNDISTURBED SOIL PLAN —BEND SECTION — PLUG SEE SECTON FOR DEPTH B SEE PLAN FOR LENGTH A 1. 2500 PS.. CONC. 2. REMOVE LOOSE EARTH AND POUR AGAINST UNDISTURBED SOIL. 3. BACKFI,.- TO EXISTING/FINISH GRADE AFTER CONCRETE HAS CURED FOR 24 HOURS 4. CONCRETE SHALL NOT COVER FLANGES, BOTS, MEGA -LUGS, RODS, ETC. BACKFILL CONIC. &.00KING— �-- I' !NDISTURSED SOIL PIAN — TEE SECTION — BEND & TEE SEE SECTION FOR DEPTH B SEE PLAN FOR LENGTH A THRUST BLOCKS DETAIL W-9 PRESSURE TAP W/ 1' CORP STOP WELDED ON CHECK VALVE VAULT DETAIL W-11 SEE STANDARD FIRE HYDRANT -GRANT TEE -- PER DETAIL NOTE: ALL PIPING SHALL BE DUCTILE IRON 4 BYPASS UNE 2 HYDRANT TE PER DETAIL 1. AS DETERMINED BY BRUNSWICK COUNTY, AWWA C508 SWING CHECK VALVE WITH LEVER & WEIGHT OR SPRING DR FLOMATiC MODEL 848/895 SPLIT DISC. 2. GATE- VALME 1WTH ROADWAY BOX & SAB AND VALVE MARKED 'WATER*. 3. FLANGED COUPLING ADAPTER 4. HYDRANT ASSEMBLY INSTALLED ON DOWNSTREAM SIDE WITHIN 50' OF CHECK VALVE. 5. ALUMINUM HATCH W/ COMPRESSION SPRING OPERATORS OR APPROVED EQUAL. 6. STEPS SPACED AT 16' O.C. 7. PRECAST REINFORCED CONCRETE VAULT WITH H2O LOAD RATING AND MIN. INSIDE DIMENSIONS 6' L X 5' W X 4' 0 S. STANDDN MODEL S89 OR APPROVED EQUAL FIXTURE SUPPORT. 9. CONCRETE THRUST COLLAR PER SPECIFICATIONS R—m- Qac: n4I1I-11 Srak: NITS C'6nkil By: WLP WIT 1 c �ryo`�clrr�'o�.tz ,rr 1t7�r1��� 3OF5 0--.` NOTE: 3 MINIMUM 10' LATERAL SEPARATON BETWEEN 3 WATER AND SEWER MAINS I� 1 i I I i HOTEs .C, 5' MAX I 5' MAX t. CON�IETE al1ALL BE �BE DFFABs STALL BE J2uEMS. z BBlnrNFOeTHRUST _. �c I COLLAR I \` ' MD nm TosEn+Ea. .::= 1. rRENCN BOT':GM x+o1H N --/—TYPICAL SEWER LOCATIONxurett a tHBusr - 5' MAX ' (NORM & WEST SIDE OF ROAD) BU—(5) NSTALLAT.Cda — — .— E BNWIMJM WIDTH. UNDISTURBED SOIL l BAIXFiLL TAMPFo R/W R Y" BAR S S a ' a "X' BAR . �; {„ I �0, a I ROADWAY I Oa I' I - a It MIN.0 —_— —W-- —_---� — —_ _W— �— z '13' 3" MIN. CLEAR. REINFORCING REQUIREMENTS R/w R/W __ Mi __.J2EIIIfORDING. BAR_iR1EQU.�TE 5' MAX \�� I.D. PIPE REBAR SIZE 'X" BAR LENGTH �'(' BAR NGIT. BAR IENCTHT Y.BARWGIIT NO. REOD. b' -?6" MS 12'-2"+O.D. PIPE 1.G43 IBS. JFI i' -Y 1.1 LBS FA -24,Y-12 !3'-0"+O.D. PIPE 02 LRS./FT 1'-3" 1.9 LBS EA. -24,Y-12 j \--ICAL WATER LOCATION REINFORCING BAR SCHEDULE I (SOUTH & EAST SIDE OF ROAD) I.D. PIPE "A" "8' 'C - 6"-16'. 20'-24 . 30 -36' 48" 6-56 6`— I 3 3 1 THRUST COLLAR FOR WATER MAINS DETAIL W-12 FOR NCDOT MAINTAINED ROADS PLACEMENT OF UTILITIES IN ROAD RIGHT-OF-WAY DETAIL W-13 DOMESTIC SERVICE. BUILDING AND NOTE 5)- ..........�... _.,.. POST INDICATOR VALVE LOCATED NITMIN 5,5' MINIMUM UT'LTY EASEMENT ADJACENT TO RIGHT-OF-WAY NOTES ..__._._. FIRE SERVICE. TYP © FD (SEE NOTE 3) 1. NO FIRE HYDRANTS ARE PERMITTED BUtIDi ( PERMITTED PRI APPROVED BACKFLOW PREVENTER ON PRIVATEFARE LINES. (2)CURBSIDE FIRE DEPARTMENT ASSEMBLY ON DDMESTIC WATER SERVIC FIRE 2_ CONNECTION A' STREET R/W OR ALONG SUPPLY -COMMERCIAL AND INDUSTRIAL HYDRANTVIC SMALL PUBLIC UBUC FIRE LANE INTERIOR TO DEVELOPMENT CUSTOMERS -MAY BE LOCATED IN WATER MAINS LOCATED TED WI A (SEE SAL) HECK IN BUILDING MECHANICAL ROOM RECORDED PUBLIC EASEMENT. THE POST INDICATOR OR VAUL7V%VE FIRE HYDRANT PRIVATE SMALL BE LOCATED AFTER THE MOST DOWNSTREAM HYDRANT CWNtt r W APPROVED BACKF.OW PREVENTER ON 'HE MAIN. R/W ASSEMBLY FOR IRRIO.ARON 3 FIRE SERVICE ONES WITH -- -- - - -- -- OR EASEMENT UNE ' SHALLBE 6" MINIMUM _ rHYDRANTS MA GOMESRCJ IRRIGATION METER DIAMETER. ITER NEIER 4. POS': INDICATOR VALVES FOR PRIVATE FRE SERVICE LINES SHALL WATER MAI VAL Yp BE LOCATED AS SHOWY:. WY'= 5 RPZ MAY BE LOCATED IN BUILDING IF BUILDING IS LESS THAN ZOO LINEAR FEET FROM THE WATER MAN SERVING THE BUILDING. ROADWAY LOCATION SCHEMATIC FOR FIRE SERVICE -DOMESTIC & IRRIGATION DETAIL W-14 MOTE 3 DISTANCE TO BE APPROVED BY COUNTY_ SEE NOTE 4 (':YP: ..Al PRIOR TO START OF WOPX BORE PIT )IEACH. END) 10' MAX SPACING FOR BORE PI: DEPTH MEASUREMENT PAVED \� ROADWAYS EDGE OF /—E I' GRAD[ DIR DRILL ^PAVEMENT MACHINE \ c \ 3 \ \ NOTE 1 10' N NOTE t `O121LL MACHINE '�- 1--� AND RODS SEL-RESTRA;NED PE/MJ ADAPTERS, NATIONAL " CABLES INTI/ S. 1 DABLES. WTI/ SWN '1 --OPEN CUT PIPE SANITATION FOUNDATION (NSF) APPROVED FOR f LINES, TYP LNES, TYP """'--J 60' MIN POTABLE WATER WTH STAINLESS STEEL SLEEVE / 60' MIN HDPE/MJ TRANSITION ASSEMBLY INSERTS AS MANUFACTURED 6Y JCM OR tr AS REQUIRED) (SEE DETAIU APPROVED EQUAL. ADAPTER BY CENTRAL. 4CRiZONTAL DIRECTIONALLY DRILLED PIPE ORISCO, FIFE OP. APPROVED EQUAL: ADAPTERS (::LASS 350 DIP, HDPE DR9 OR FUSIBLE PVC TO BE SON 11 DR 9TYP BOTH ENDS). SEE T (DR18); SEE SIZING CHART) HOPE/MJ TRANSITION ASSEMBLY (AS REQUIRED) (SEE DETAL)---) HDPE/MJ TRANSITION ASSEMBLY WS -4A DIRETIONAE DRIES D E - A. I E 'I,Ng, -- 4 EXSTINC GRADE TE "ISOLATION" THRUST -BLOCK HOPE DIAMETER. CONVERSION TABLE NOMINAL FEN CUT NOMINAL HDPE DR9 HDD PIPE SIZE PIPE SIZE (INCHES) (INCHES) VALVE - PLUG, CATE, OR BUTTERFLY. PER 8R'JNSMCK COUNTY TECHNICAL SPEORCATIONS (ONLY IF SROM ON PLAN SHEETS OR AT THE DISCRETION OF BRUNSWICK ADAPTER BEL /\ BELL h SPIGOT ,!ONT ` FE+-- ANCE VARIrS� i 20' MINIM.JM \ !� a I RAS APPP.CVED BY • BPUNSWCK COUNTY a e . x i ��^ „ •�i V t, 1 o RESTRA;NEO JOINT (S- NOTE 9) \-HDPE PIPE \-DUCTILE IRON PIPE OR RESTRAINED JOINT PVC (MEGALUG) HDPE ANCHOR -RING TRANSFERS E%PANSION AND CON-RACNON FORCE INTO CONCRETE BLOCK WHICH TRANSFERS IT INTO THE SOIL WTHTHE ASSEMBLY REMAINING STA.TIGNARY. THIS PREVENTS THE UP -STREAM D.I. SLIP JOINT FROM BEING PULED A?ART. NOT REQUIRED FCR FUSBIE P"V„ OR HDO DIP HDPE/MJ TRANSITION ASSEMBLY WS -48 NOTES AN AS -BUILT PLAN AND PROFILE SHALL BE PRO'VTO'e0 FROM ENTRY TO EXIT FOR, EACH DIRECTIONAL BORE SECDON BY THE DIRECTIONAL BORE CONTRACTOR. THIS SHALL INCLUDE ACCURATE HCRIZONTAL AND VERTICAL DIMENSIONS AND SHALL MEET OR EXCEEC NCDOT VERTICAL REQUIREMENTS FROM HDD PIPE TO EDGE OF PAVEME.N'. 2 ALL BORE SEC'IIGNS SHALL RE HYOROSTATCALLY TESTED PER COUNTY STANDARDS AFTER INSTAIE.ATICN, AND PRIOR TO CONNECTION TO THE FEN CUT WATER] SE'NER UNE A FINAL TEST WILL BE A PAR. OF THE TOTAL MAIN UNE SYSTEM TEST. LENGTH OF r{OSSING, LOCATION OF INSPECTION/OBSERVATION EXCAVATION, NUMBER OF PDC PPE JONTS, LOCATION OF DRILL MACHINE AUGER ENTRANCE LOCATION AND TIE-IN POINTS ARE .0 BE AP?ROVED BY COUNTY PR -ON TO ANY START OF WORK. A. ON CONVENTIONAL ITGHNAYS, AS A MINIMUM. THE 4DD PIPE SHALL EXTEND 10 THE ND SHOULDER BREAK CR 10 =EE- BEYOTH EDGEOr PAVEMENT ON FILL SLOPES. W,ICHEVER IS GREATEP. 3 FEET BEYOND THE DITCH LINE IN CUTS; AND ON c LE L CURBED SECTIONS '0 THE BACK OF THE SIDEWALK AREA. ON FREEWAYS, E%FRESSWAYS, AND OTHER CONTROLLED ACCESS HIGHWAYS, THE HDD PIPE. WILL BE REQUIRED TO EXTEND TO THE ACCESS CONTROL LINES. TO THE OUTSIDE OF FRONTAGE ROADS. OR A SUFFICIENT DISTANCE TO ALLOW FOR FUTURE HIGHWAY IMPROVEMENTS, OR AS REQUIRED BY THE NCCDT ENCROACHMENT AGREEMENT. 5. THE BETE DEVELOPED FOR IHE DIRECTIONALLY DRILLED PIPE SHALL BE KEPI AT A MINIMUM DIAMETER FOP, THE PIPE i4STAilATON. THE AUGER HEAD SIZE SNAIL BE APPROVED BY THE COUNTY PRIOR TO THE START OF WORK. 6. HCRZON-AL DIRECTCNAL DRILL OF NCDOT STATE ROADS TO BE APPROVED BY NCOOT PRIOR TO CONSTR.UCT:.CN. PIPE MATERIAL AND THICKNESS MAY VARY. Z. THE CCNTP.ACTOR SHALL ALLOW SUFFIGENT LENGTHS OF PIPE TO EXTEND PAST THE TERMINATION POINT TO ALLOW FOR CONTRACTION. PULED HDO PIPE SHALL. BE. ALLOWED TO RELAX : DAYS OR THE AMOUNT OF ?IME RECOMMENDED BY THE MANUFACTURER PRIOR i0 MAKING CONNECTIONS. B. FUSIBLE PVC HAS BEEN APPROVED FON USE MTHIN NCDOT RICHT. OF WAYS. SEE CURRENT NCDOT SPECIFICATION PAGE 10.58; NOTES 1036-3(4)(1)(2) 9. MINIMUM Of (3) RESTRAINED JOINTS ARE REWIRED UPSTREAM AND DOWNSTREAM OF DIPjHDPEAUSIBLE PVC MJ ADAPTEP ON EACH END OF THE HORIZONTAL DIRECTIONALLY DR,_LED PIPE UNLESS OTHERWISE APPROVED BY BRUNSWICK COUNTY. ADJUSTABLE CAST IRON VALVE BOX VALUE -PLUG, GATE, OR 36" MIN BU TEEPEE, PER BRUINStWCK COUNTY TECHNICAL SPECIFICATIONS ' N -Y IF SHLWN ON THE PLAN SHEETS CR AT THE DISCRETION BEND ANGLE TO OF BRJNSWICK COUNTY) \ NOTA: PE PVC TO BE DETERMINED PER A^TIAL RE MJ INEC FIELD C NDITIONS 1. IRIS DETAIL IS A GENERAL SCHEMATIC SHO'WNG ISTM.ATiON VALVE LDCAT:C NS AND AIR BRICK SUPPORT TYP. - TO MJ BEND RELEASE VALVES ( ) - VALVE & BOX VALVE & 20X 2 RNA.L LOCATION OF PIPE APPURTENANCES SHALL BE COORDINATED WITH BRUNSWICK COUNTY . PVC PIPE TO ALONG 'WITH PIPE MATERIAL .AND METHOD OF CONSTRUCTION, BE RESTRAINED �T 1'— ?TPUL TRACER WIRE OPEN -CUT ?IPE PVC OR DIP ' DJP \\' TO MJ BEND I I I I—I I I I INTO 'dAL'vE BOX _7 WATEP, SURFACE - 1 \ BE% - PVC TO BE RES -PLA NEC j 'aLC B(t. FLOW TC MJ VALVE / ry00 OOR FLOW r\ _ iD' MIN. 1 P l� WRAP AROUND / •. - AIR RELEASE VALVE FORCE MAN) OR � � PIPE VM'H �� DEFORMED BARS �'- - FIRE HYDRANT (WATER) AT HIGH POINT - a• _• . �.\ FOR FLUSHING (PER DETAIL) 5.5" CIA t TRACER WIRE 12 GA • / COPPERHEAD SUPER FLY 10' MIN (OR APPROVED EQUA;.) OPEN—CUT PIPE TO FUSIBLE P'JC17 OR HDD DIP TRANSITION ASSEMBL W_S=4C -. 4D?E. DIP OR FUSIBLE PVC UIREC7iONALLY DRILLED PIPE � i VALVE LOCATIONS FOR DIRECTIONAL DRILL OF PIPE UNDER W'ETLANDVINATER B-ODY DETAIL WS -5 PLAN VIEW I I TONE CROSS SECTION NOTES: 1. UNRESTRAINED SEWER LINES ON 20% SLOPE OR GREATER SHALL BE ANCHORED SECURELY WITH CONCRETE COLLARS MINIMUM 1 CONCRETE COLLAR PER PIPE JOINT. ADDITIONAL COLLARS MAY BE REQUIRED BY ENGINEER. 2. COLLARS FOR ANTI -SEEPAGE (PIPING) CONTROL FOR PIPELINES CONSTRUCTED THROUGH WETLANDS SHALL BE INSTALLED AT LOCATIONS SHOWN ON THE PLANS PIPE COLLAR DETAIL WS -8 PRE -CAST REINFORCED CONCRETE VALVE BOX COLLAR MAY BE OMITTED IN PAVED SECTIONS — RECLAIMED OR WATER ON COVER GRADE TO BE ESTABLISHED TO ALLOW FOR DRAINAGE AWAY FROM CONCRETE COLLAR FINISHED GRADE -MARKER HAS HIGH IMPACT RESISTANCE DUE TO HIGH FLEXIBILITY. 1. VALVE MARKER TO BE INSTALLED UPRIGHT WITH THE V -MAY REQUIRE A SMALL PILOT HOLE IN CERTAIN SOIL CONDITIONS BEFORE INSTALLATION. — LOCATE ARE TO EXTEND OUTSIDE 2. DIRECTION AND DISTANCE MUST BE ETCHED OR STAMPED (NATER -W, SEWER -S, RECLAIMED -R). OF VALVE BOX, BEND ENDS OVER DISTANCE, & DIRECTION TO VALVE 3. ONE POST TO BE INSTALLED FOR EACH VALVE LOCATED UP OF VALVE BOX BEFORE OUTSIDE OF THE PAVEMENT. n INSTALUNG UD i 3 NTO POST WAY. BRICK UNDER EACH 5. NO VALVE MARKER REQUIRED FOR FIRE HYDRANT SIGMA, OR APPROVED EQUAL - SIDE OF VALVE BOX ISOLATION VALVES. CAST IRON VALVE BOX RECLAIMED) 6. PAINT VALVE MARKER USING STANDARD LOCATING ADJUSTABLE 'SCREW TYPE' 9+ STONE BEDDING UNDER COLORS: VALVE BOX VALVE AS SHOWN ON 0) WATER - BLUE PLANS (MEGA LUGS/ TRACER MI�'E GRIP RINGS REWIRED) (SEE NOTE BELL RESTRAINT I (MEGALUG OR APPROVED EQUAL) REWIRED ONE JOINT EACH SIDE OF BELL RESTRAINT VALVE (MEGALUG OR APPROVED NOTES: -MARKER HAS HIGH IMPACT RESISTANCE DUE TO HIGH FLEXIBILITY. 1. VALVE MARKER TO BE INSTALLED UPRIGHT WITH THE V -MAY REQUIRE A SMALL PILOT HOLE IN CERTAIN SOIL CONDITIONS BEFORE INSTALLATION. CAST 'MV' FACING THE NEAREST STREET. 2"0 STAMPED BRONZE INSERT WITH TYPE 2. DIRECTION AND DISTANCE MUST BE ETCHED OR STAMPED (NATER -W, SEWER -S, RECLAIMED -R). INTO THE BRONZE INSERT. DISTANCE, & DIRECTION TO VALVE 3. ONE POST TO BE INSTALLED FOR EACH VALVE LOCATED OUTSIDE OF THE PAVEMENT. 4' HIGH 'MV CAST 4. VALVE MARKER TO BE INSTALLED AT THE RIGHT OF NTO POST WAY. R/W 5. NO VALVE MARKER REQUIRED FOR FIRE HYDRANT FOR SEWER rlOR ISOLATION VALVES. CONCRETE VALVE RECLAIMED) 6. PAINT VALVE MARKER USING STANDARD LOCATING COLORS: 0) WATER - BLUE b) SEWER - GREEN c) RECLAIMED - PURPLE 2' MINIMUM 3 7YP VALVE BOX & COVERS rTMP. FINISHED GRADE rc I 4' 6' 27' CONCRETE COLLAR VALVE MARKER IN RIGHT OF WAY PAVED DETAIL WS -11 POURED IN PLACE CONC EQUAL) REQUIRED ONE W/ TIE DOWNS REQUIRED '—CONC SUPPORT JOINT EACH SIDE OF (M4 BARS) FOR 1D' AND VALVE LARGER VALVES TYP CONC SUPPORT: PRECAST BLOCKS MAY BE USED FOR LESS THAN 10' VALVES (FIELD CONDITIONS MAY REWIRE ADDITIONAL RESTRAINTS) NOTES: 1. TOP OF VALVE BOX AND COLLAR SHALL BE PAINTED GREEN FOR SEWER FM. PURPLE FOR RECLAIMED WATER. AND BLUE FOR WATER. 2. EXTENSION STEM WILL BE REQUIRED TO BE WITHIN 2 FEET OF THE SURFACE IF OPERATING NUT WOULD OTHERWISE BE OVER 5 FEET BELOW GRADE EXTENSIONS SHALL BE PERMANENTLY ATTACHED TO VALVE NUT AND SHALL BE PROVIDED WITH HORIZONTAL SPACERS FOR VERTICAL ALIGNMENT WITHIN THE VALVE BOX_ 3. MINIMUM CLEARANCE TO EXTENSION IS 8. 4. WIRE COLORS REQUIRED: SEWER-GREEN/WATER-BLUE/RECLAIMED WATER -PURPLE OR GREEN NTH PURPLE STRIPE 5. 12 GA. COPPERHEAD SUPER FLEX TRACER WIRE OR APPROVED EQUAL CONCRETE VALVE MARKER 5' VALVE BOX DETAIL WS -9 I BELL I— 6' O.D. � 6' 6' MIN, V BELL C C O.D. � . SECTION "A" NOTES: �J q -MARKER HAS HIGH IMPACT RESISTANCE DUE TO HIGH FLEXIBILITY. TWO FLAT SURFACES ARE PROVIDED FOR ANY DECAL APPLICATION NEEDED. V -MAY REQUIRE A SMALL PILOT HOLE IN CERTAIN SOIL CONDITIONS BEFORE INSTALLATION. V A -ONE POST TO BE INSTALLED FOR EACH VALVE LOCATED OUTSIDE OF THE PAVEMENT. A L -WITNESS POST TO BE INSTALLED AT THE EASEMENT EDGE. L V -NO POST REQUIRED FOR FIRE HYDRANT ISOLATION VALVES. V E E M M A A R 2' MIN R K E E R I WATER OR SEWER ----\ WATER VALVE W S FOR SEWER rlOR (USE 'R' FOR CONCRETE VALVE RECLAIMED) COLLAR (TYP) VALVE MARKER IN EASEMENTS (UNPAVED) DETAIL WS -10 GUNGKtIt tNGAJtU FIFt DETAIL WS -12 6" MIN. r 8. 4 - /5 HORIZ. /r 4 6' MIN. n 6' NIN. UNDISTURBED EARTH ON ALL SIDES CONCRETE ENCASEMENT DETAIL PIPE BELL 2500 PS CONCRETE (MIN) 04 STIRRUPS 0 18' R— 1MoDD 715/2S0 1& 0E oadm A W Oz �0 w`LU u z V s�ulc: NTS a,.on ey: rom CTckN By: WLP 4OF7 TRACER WIRE TC EXTEND OUTSIDE OFVALV< 80X, BEND ENDS OVER LHP OF V.'LL.'•'E BOX BEFORE INSTALLING LID NOTES: 1. PROVIDE TRACER WIRE ON ALL NON-FERROUS PIPELINES. 2 TRACER W§RE NOT REQUIRED OLIFIRE HYDRANT :SOUJOR 'VALVES 12 GA. "COPPERHEAD SUPER FLEX" ��TRACER'MRE (OR APPROVED EQUAL) i 1/2' POLYETHYLENE TAPE VF?hPPE11 AROUND TWICE 1 Fes- 70' MAX. c NOTE: TRACER WIRE AT VALVES MRE COLOR REQU:REO • SEWER -GREEN ET iIL 'NS- l WATER -BLUE • RECLAIMED WATER -PURPLE OR GREEN WITH PURPLE STRIPE SI.PHCN BR NCT: HOSE BIB SHALL AC'LOMMOD.AT STANDARD 3/4' GARGEN HOSE. P L 2 T'xt' MIN PAVER ;F LOCATED IN GRASS AREA 1 CF 111 57 WASHED STONE----�� xyG DEVICE TOP OF SLAB �-PL E G.D.ZE PhS'.6'. PTFE SIUSSHCWN ON FLANS. 3/8' x 2' STAINLESS STEEL STRAP KPH 2-1; * LEG VARIES -PROVIDE WSHIG'vING INSUI.ATCi BE iw':EN T 2 STAINLESS STEEL 1/2' STEEL ANVUpt //'PIPE R STEEL SCRAP AND BE -WEEN PIPE / F,CIT MTi 4' / k CONt7t'_E 'AD_, ANCHOR BOLTS FROF_CTION AND NUT -- CRADLE FfRkEO 70 PE BCTTOM THIRD Gf PIPE CONCREIE 1 PER 4 - y4 BARS BENT_ /3 BARS 8 r. . GRACE,-- III't��� -tj� -CONCRETE SHALL BE 3.000P.S.I. MIN. 'PRCX STAINLESS STEEL xSTR.AP RMT 2-1,12* LEG , --- `-3/" x 2' STAINLESS STEEL SlkRul-ILENED 1O11T / AP WTH 2-1/2' LEG DUCTILE RGN PIPE -� PLAN `"EY! I VAPoABLE__. fii �1 ,/2 ANCnCR BOLT 1 4" PR,OJECTON AN UT (---� ! �1' 02 0" ENG VIEW TRAINED JOINT 0001 'M z-: T OF PIES I) PIERS OVER 3'-D" IN HEIGHT TC BE -� REINCi-IRCEO. A 9'i\` A 4 - #4 BARS 2) SET PIPE BOTTOM A MINIMUM OF 2' ABOVE THE CONCRETE PIER VERT. (BENT) 25 YEAR WATER SURFACE ELEVATION. . PRO:X. GRADE 3) CAST -114 -PLACE CONCRETE SHALL 8E FIELD TESTED. / 4) AT A MINIMUM, ONE PER MUST BE INSTALLED EVERY 20 -FT OR AS DIRECTED BY THE ENGINEER. 5) ENGNEER SMALL VERIFY FOUNDATION REOUIP.EM- S. _ T REDAR SIZE, AND ALL OTHER DIMENSIONS. �3 BARS A 12' G.C. SIDE +: " E4! SECTION „—A" AERIAL PIPE CROSSINC DETAIL '06-15 ELAN FOR VALVES NOTE: OUTSIDE OF FOR VALVES WITHIN NCDOT R/W NCDOT R/W COLLAR SHALL BE PIACED AT SET COLLAR I' FINISHED GRADE ABOVE FINISHED GF ADE TOP OF VALVE &OX LEVEL W/COLLAR TO ' 1/2" RECESS. ID' NON -TRAFFIC \ / NOT REQUIRED IN FINISfifO GRADE PAVED SECTIONS .. a ° a \ VALVE BOX 24' DIA. SEC CN A—A PRECAST CONCRETE VALVE BOX COLLAR_ DEI.AIL WS -16 Y EXISTING GROUND 3 FEET MIN. FOR PVC / HDPE WATER/SEWER (DIP OR C900 PVC) 24" CLEARANCE PREFERRED OR AS APPROVED BY BRUNSWICK COUNTY )ME JOINT FROM RESTRAINED JOINT FITTING45 DEGREE MAXIMUM BEND (TVP.) ol: STORM WATER CULVERT INVERT OR DITCH BOTTOM AS DETERMINED BY CULVERT FLOW LINES 24" MIN.CLEARANCE OR ENGINEERED SOLUTIONS PER 2T 4c� RULES Lq P fJ, l RESTRAINED JOINT(TYP) MEG -A -LUG OR EQUIVALENT AS MANUFACTURED BY EBBA IRON, ROMAC, SMITH-BLAIR, WATER/SEWER (DIP) ETC. JOINT REWIRED NOTE-. USE STAINLESS STEEL THREADED RODS, MEGA -LUG, OR APPROVED EQUAL FOR JOINT RESTRAINT DITCH AND/OR STORM DRAIN CROSSING OFFSETS BETWEEN WATER/SEWER PRESSURE MAIN AND STORM DRAIN DETAIL WS -20 DEPTH < 2CI FEET - CLASS "A" BEDDING • UNDERCUT TRENCH BOTTOM 6 INCHES MINIMUM BELOW PIPE • FILL PIPE TO SPRING LINE WITH NO. 57 STONE DEPTH > 20 FEET - CLASS "B" BEDDING • UNDERCUT TRENCH BOTTOM 6 INCHES MINIMUM BELOW PIPE • FILL TO 6 INCHES ABOVE PIPE WITH NO. 57 STONE INSTALLATIONS THAT EXCEED 20 FEET DEPTH SHALL DIP TYPE1 OR 2 FINAL BACKFILL PER BRUNSWICK COUNTY— SPECIFICATIONS TYPE 1 INITIAL BACKFILL PER BRUNSWICK COUNTY SPECIFICATIONS CLASS A OR B BEDDING PER BRUNSWICK COUNTY SPECIFICATION$ STABLE FOUND ONONN NOTES: 1. REFER TO THE BRUNSWICK COUNTY TECHNICAL SPECIFICATIONS BACKFILL AND TRENCHING REQUIREMENTS 1. PIPE SIZE AS INDICATED ON PLANS GRAVITY SEWER PIPE TRENCH / BEDDING DETAIL DETAIL WS -22 ELECTRONIC MARKER BALL. TYP 0 TOP PLAN NII ELECTRONIC MARKER BALL, y TYP 18" MIN 24" NO 48" MAX ® 6" MIN SECTION NTS SEWER (DIP) STONE PLACE STONE TO SPRING LINE OF PIPE NOTES 1. BOTH THE WATER MAIN AND THE SEWER MAIN SHALL BE FERROUS MATERIALS WITH JOINTS EQUIVALENT TO WATER MAIN STANDARDS FOR A MINIMUM DISTANCE OF 10 FEET ON EACH SIDE OF THE CROSSING. 2. ALTERNATIVELY, PIPES MAY BE SLEEVED WITH FERROUS MATERIALS FOR A MINIMUM DISTANCE OF 10 FEET ON EACH SIDE OF THE CROSSING AS APPROVED BY BRUNSWICK COUNTY ENGINEERING. SEWER CROSSING ABOVE WATER LINE NOTES 1. ELECTRONIC MARKER BALL MATERIALS SHALL BE AS FOLLOWS: o. WATER - 310 SCDTCHMARK ELECTRONIC MARKER, MODEL N 1403-XR, 4 -INCH DIAMETER, BLUE 6. SEWER - 3M SCDTCHMARK ELECTRONIC MARKER, MODEL III 1404-XR, 4 -INCH DIAMETER, GREEN C. RECLAIMED WATER - 3M SCDTCHMARK ELECTRONIC MARKER, MODEL M 1408-XR, 4 -INCH DIAMETER, PURPLE 2. PLACEMENT SHALL CONFORM TO DETAILS ABOVE. FOR FURTHER GUIDANCE, REFER TO BRUNSWICK COUNTY TECHNICAL SPECIFICATIONS SECTION TITLED 'ELECTRONIC MARKER BALLS FOR WATER AND SEWER FORCE MAINS". Rcvlsions 1.1 - DATFD 7/12/2013 YIodificd Note Ic 1 2 - DATED 1/16/2014 Add. WS - 212122,,d umbered WS -2l PLACE STONE TO SPRING LINE OF PIPE HATER LINE • ••• SEWER LINE a STONE U D 0 U 3 3EDDING C/) z NOTES: 1. SOIL REPLACED UNDER THE WATER MAIN SHALL F-�--/ BE COMPACTED. M 2. IF THE WATER MAIN CROSSES AT LESS THAN W 18' ABOVE THE SEWER MAIN BOTH THE WATER w MAIN AND THE SEWER MAIN SHALL BE O FERROUS MATERIALS WITH JOINTS EQUIVALENT TO WATER MAIN STANDARDS FOR A MINIMUM DISTANCE OF 10 FEET ON EACH SIDE OF THE CROSSING, OR THEY MAY HAVE FERROUS L SLEEVES PUT AROUND THEM AS APPROVED BY BRUNSWICK COUNTY ENGINEERING. SEWER CROSSING BELOW WATER LINE 0 SEWER OFFSETS ABOVE AND BELOW WATER MAINS DETAIL WS -21 SLOPE WALLS TO ANGLE R POSE OF SOIL OR AS 1 ,►�,,,,,I,,,,,�APPROVED BY THE ENGINEER PATH MARKING: PLACE 1 MARKERS ADJACENT TO ELECTRONIC TEE OR OR NOTES: 1. REFER TO THE BRUNSWICK COUNTY TECHNICAL SPECIFICATIONS BACKFILL AND TRENCHING REQUIREMENTS 1. PIPE SIZE AS INDICATED ON PLANS GRAVITY SEWER PIPE TRENCH / BEDDING DETAIL DETAIL WS -22 ELECTRONIC MARKER BALL. TYP 0 TOP PLAN NII ELECTRONIC MARKER BALL, y TYP 18" MIN 24" NO 48" MAX ® 6" MIN SECTION NTS SEWER (DIP) STONE PLACE STONE TO SPRING LINE OF PIPE NOTES 1. BOTH THE WATER MAIN AND THE SEWER MAIN SHALL BE FERROUS MATERIALS WITH JOINTS EQUIVALENT TO WATER MAIN STANDARDS FOR A MINIMUM DISTANCE OF 10 FEET ON EACH SIDE OF THE CROSSING. 2. ALTERNATIVELY, PIPES MAY BE SLEEVED WITH FERROUS MATERIALS FOR A MINIMUM DISTANCE OF 10 FEET ON EACH SIDE OF THE CROSSING AS APPROVED BY BRUNSWICK COUNTY ENGINEERING. SEWER CROSSING ABOVE WATER LINE NOTES 1. ELECTRONIC MARKER BALL MATERIALS SHALL BE AS FOLLOWS: o. WATER - 310 SCDTCHMARK ELECTRONIC MARKER, MODEL N 1403-XR, 4 -INCH DIAMETER, BLUE 6. SEWER - 3M SCDTCHMARK ELECTRONIC MARKER, MODEL III 1404-XR, 4 -INCH DIAMETER, GREEN C. RECLAIMED WATER - 3M SCDTCHMARK ELECTRONIC MARKER, MODEL M 1408-XR, 4 -INCH DIAMETER, PURPLE 2. PLACEMENT SHALL CONFORM TO DETAILS ABOVE. FOR FURTHER GUIDANCE, REFER TO BRUNSWICK COUNTY TECHNICAL SPECIFICATIONS SECTION TITLED 'ELECTRONIC MARKER BALLS FOR WATER AND SEWER FORCE MAINS". Rcvlsions 1.1 - DATFD 7/12/2013 YIodificd Note Ic 1 2 - DATED 1/16/2014 Add. WS - 212122,,d umbered WS -2l PLACE STONE TO SPRING LINE OF PIPE HATER LINE • ••• SEWER LINE a STONE U D 0 U 3 3EDDING C/) z NOTES: 1. SOIL REPLACED UNDER THE WATER MAIN SHALL F-�--/ BE COMPACTED. M 2. IF THE WATER MAIN CROSSES AT LESS THAN W 18' ABOVE THE SEWER MAIN BOTH THE WATER w MAIN AND THE SEWER MAIN SHALL BE O FERROUS MATERIALS WITH JOINTS EQUIVALENT TO WATER MAIN STANDARDS FOR A MINIMUM DISTANCE OF 10 FEET ON EACH SIDE OF THE CROSSING, OR THEY MAY HAVE FERROUS L SLEEVES PUT AROUND THEM AS APPROVED BY BRUNSWICK COUNTY ENGINEERING. SEWER CROSSING BELOW WATER LINE 0 SEWER OFFSETS ABOVE AND BELOW WATER MAINS DETAIL WS -21 ROAD CROSSING WATER CROSSING 1 CAPPED I>j CHANGE IN PLUGGED PIPE - END DIAMETER 1 CHANGE ARC - PLACE PIPETYPECASING ENDS MARKER EVERY 25 FT OF DEFLECTION ELECTRONIC MARKER BALL PLACEMENT DETAIL DETAIL WS -23 TOP PLAN NTS • ME is fi ma. uz -o Scilc: MS m.,m sr roM (LukW Br: t41P u 1 TILSs ��'+ s _ t SEA' 70F7 TEE, PATH MARKING: PLACE CROSS, MARKERS ADJACENT TO ELECTRONIC TEE OR OR ABOVE GROUND LANDMARKS MARKER LATERAL LATERAL SUCH AS OLES, BALL, TYP • MUST MAINTA NP L NE VHONE SIGHT BEPOINTS. ACCESS POINT UTILITY CROSSING GAS • • • RAILROAD CROSSING ROAD CROSSING WATER CROSSING 1 CAPPED I>j CHANGE IN PLUGGED PIPE - END DIAMETER 1 CHANGE ARC - PLACE PIPETYPECASING ENDS MARKER EVERY 25 FT OF DEFLECTION ELECTRONIC MARKER BALL PLACEMENT DETAIL DETAIL WS -23 TOP PLAN NTS • ME is fi ma. uz -o Scilc: MS m.,m sr roM (LukW Br: t41P u 1 TILSs ��'+ s _ t SEA' 70F7