Loading...
HomeMy WebLinkAbout20080214 Ver 1_More Info Letter_20080215~QF WATF9Q Michael F. Easley, Governor `~ ~i William G. Ross Jr., Secretary ~ rte.- North Cazolina Department of Environment and Natural Resources ~ ~ ~ ~- Coleen H. Sullins, Director Division of Water Quality February 15, 2008 DWQ EXP No. 08-0214 Wake County CERTIFIED MAIL: RETURN RECEIPT REQUESTED Wake County Public School System Attn: Mr. Charles French 1551 Rock Quarry Road Raleigh, NC 27610 Project Name: E-27 (Fuquay Elementary School) REQUEST FOR MORE INFORMATION On February 14, 2008, the Express Review Program of the Division of Water Quality (DWQ) received your application for the above referenced project. The DWQ has determined that your application will require additional information. Please provide the following information so that we may continue to review your project and prevent denial of your application as required by 15A NCAC 2H .0506: Additional Information Requested Bioretention Area A: a. Please provide a completed BMP Supplement for the proposed Bioretention including the design summary and the required items checklist. b. Please specify the source and permeability of soil media on plan sheet C7.9 (1"-2" per hour is preferred). Please be reminded that the ponded water shall completely drain into the soil within 12 hours, and to a level of 24 inches below the soil surface within 48 hours. c. Allowable range of phosphorus index is 10 - 30. Sheet C7.9 indicates a P-Index of less than 50. Please revise the P-index to conform to the acceptable range. 2. Exterior Level Spreader (Receiving flow from Bioretenton) a. Please provide Level Spreader Supplement Form (design summary and required items checklist) along with a notarized Inspection and Maintenance Agreement Form. Stormwater Wetlands B 1 and B2: a. Please provide a completed BMP Supplement for each proposed BMP including the design summary and the required items checklist. b. Please specify source of wetland plants on plan sheet C7.11. c. Please specify permeability of clay liner on site plans. (Typical infiltration rate is 0.01 in/hr). d. The percentages of total wetland surface area allotted to the shallow land and shallow water areas as indicated on Site plans C3.3 and C3.4 do not seem to conform to those indicated in the supporting design calculations. The shallow water seems to be far greater than 40% (>50%) while that of the shallow land seems to be far less than 40%. Please apportion surface areas at the permanent pool level to all zones. You may want to increase the shallow land area. 401 Oversight /Express Review Permitting Unit 1650 Mail Service Center, Raleigh, North Carolina 27699-1650 2321 Crabtree Boulevard, Suite 250, Raleigh, North Carolina 27604 Phone: 919-733-17861 FAX 919-733-689311ntemet: http://h2o.enr.state.nc.us/ncwetlands Nose Carolina ~tura!!r~ An Equal OpportunitylAffirmativeAaion Employer - 50% Recycled110% Post Consumer Paper - - - ,. E-27 Fuquay Elementary School Page 2 of 2 February 15, 2008 da s of the date of this letter by sending two (2) copies of the above Please respond within five (5) py rocess that requires all parties to participate in a information in writing. The Ex ress Review Program is a p timely manner. onl addresses the application review and does not authorize any impalication are not waters This letter y or protected buffers. Please be aware that any impacts requested within your ap authorized (at this time) by the DWQ• ott at 919-733-1786 if you have any questions regarding or Please contact Joseph Gyamfi or Lia My would like to set up a meeting to discuss this matter. Sincerely, Cyndi Karoly, Supervisor 401 Oversight/Express Review Permitting Unit CBK/jg cc: James Shern, USACE Raleigh Regulatory Field Office Lauren Witherspoon, DWQ Raleigh Regional Office File Copy Soil & Environmental Consultants, PA, 11010 Raven Ridge Rd, Raleigh, NC 2761 Central Files James Dasher,