HomeMy WebLinkAbout20110984 Ver 2_Application_20160503Transportation
May 3, 2016
U.S. Army Corps of Engineers
Wilmington Regulatory Field Office
69 Darlington Avenue
Wilmington, NC 28403
ATTN: Ms. Elizabeth Hair
NCDOT Division 6 Coordinator
Dear Madam:
PAT McCR�RY
Governar
NICHOLAS j. TENNYSON
Secretary
Subject: Modification Request for Sections 404 & 10 Individual Permit & Section 401
Water Quality Certiiication for the replacement of Bridges No.12, 18 & 42 on
NC 11 over the Cape Fear River and Overflow; Federal Aid No. BRSTP-
0011(9).TIP Project No. B-4028. Debit $570.00 from WBS No. 33395.2.2.
References: Section 401 Water Quality Certification Permit dated January 11, 2012.
Sections 404 and 10 Individual Section Permit May 16, 2012.
Sections 404 and 10 Individual Section Permit Modification issued June 19,
2012.
The North Carolina Department of Transportation (NCDOT), Division of Highways requests a
Modification of the Individual Permit, U.S. Arrny Corps of Engineers Action ID SAW-2002-
00645 and associated Section 401 Water Quality Certification. The Department has recognized
that drift is accumulating at the bents within the Cape Fear River. The bents consists of 2 sets of
6 pipe piles (18" diameter) driven into the river bed with 13.5' x 16.5' concrete footer elevated
above normal water surface elevation. When the Cape Fear River rises due to upstream runoff,
drift while flowing downstream builds up on the river bents. The drift can entangle with the pipe
piles which will cause severe damage. The Resident Engineer's Office has engaged the Bridge /
Structure Design Group, Hydraulics, Geotechnical Units and the contractor HRI Bridge, Ine., to
develop a system that will ultimately protect the river bents. Please reference the attached plans.
A debris deflector will be installed at the bents to eliminate the entanglement of drift. At Bent 1,
Marine Sheeting will be driven into the river bed approximately 22' which will be below the
elevation of Critical Scour. The sheeting will extend from the toe of slope of the river on the
upstream along the two footers and then back into the toe of slope of the river which coincides
with sheeting that was previously installed to protect the existing bent outside of the river. Class
2 rip-rap stone with Class B stone will be placed between the concrete footers and the river bank.
The rip-rap will extend to the end bent where rip-rap has already been placed. Between the
sheeting and the concrete footer, sedimeni will accumulate and eventually fill in the void. A total
Open Water Impact of 1,785 sq. ft. (0.04 acre) will be required.
�Nothing Compares��
State of North Carolina I Department of Transportation I Division 6
1000 Transportation Drive Fayetteville, NC 28302
910 437 0207
At Bent 2, a Debris Deflector will be installed. The upstream deflector will be constructed using
Marine Sheeting driven into the river bed approximately 20' which is below the elevation of
Critical Scour. Once installed, the deflector will be filled with #57 aggregate and capped with
concrete. Marine Sheeting will also be driven along the sides of the concrete footers so drift
cannot get caught in the sides. The downstream will not be enclosed so that Bridge Maintenance
Unit can inspect the pipe piles. A total Open Water Impact of 579 sq. ft. (0.01 acre) will be
t•equired.
Regulatory Approvals
Section 404: We are hereby requesting modifications described above for the USACE Sections
404 and 10 Individual Section Permit issued May 16, 2012 (SAW 2002-00645) for the above
described activities.
Section 401: We are hereby requesting a modifcation to the 401 Individual Water Quality
Certification from NCDEQ issued January 11, 2012 (DWR Project No. 110984). In compliance
with Section 143-215.3DE of the NCAC, we will provide $570.00 to act as payment for
processing the Section 401 Permit Modification.
A copy of this modification request and its distribution will be posted on the NCDOT website at
https•//connect ncdot.�ov/resources/Environmental.
If you should have any questions, or need additional information please contact James J. Rerko,
PWS at (910)437-0207.
Sincerely,
-�or Philip S. Harris, III, P.E., Manager
Natural Environment Section
cc: Mason Herndon, NCDWR
�
135° -00'-00' �`
1
EXISTING FOOTINC '�
<T YP.)
� �\�
� � •.�
i�
♦i�� � `1\�
�_.� � � ��
�i
r.'` ` �,1 ;2..6• ,\
L
,� '�—, ,: ♦
♦ �
♦ ♦ '.' `' �'. , \
♦ 1
♦ � � i� \'. � �
♦
♦ ���\ ♦
, � 1. � \
♦ � � i� ,\ ♦
, _` '��.
♦ I ♦ \
i
♦ � � �i� 'v!
♦ ��i �i� ,� o
, ''� .
��i
WATER•S EOGE �,��
'�'�'�'�'� '�'�'�',�'� '�
D \
�
�Ir\.
`° �i�� �\
� �� � � � �
a ��� 1 1 ��
o; ♦�� � � + �
♦ � � `�,
; ♦ '.' `, � �
� ` ' ,,, �
�. ♦�
♦ �'. ♦�.
♦ � � ♦�
♦ �� �� � ���
� ♦ .
♦ I �1 ♦ '�
1 �
n? � �� �� ♦
o ♦ .�_
� ,-. ��.
� � � �.
� �.
� `�. �.
♦ �.�
��. �Z,.o
�ss^-oo•-oo---�
EXISTING
GALVANIZEO
STEEL PIPE
PILE (TYP.)
�
�
�
SEE DETAIL •A'
ClASS II RIP RAP
LEVEI TOP $URFACE WIiH COIT CONNECTOR
CLA55 "B" RIP RAP (TYP.)
STEEI SHEET PIIE
(TYP.)
PLAN
STEEI SHEET PILE
DETAIL 'A'
r
c�
�
�
�
9�
-L- �p
L
�'�'�'�'�' .�.�. ; �
�
BILL OF MATERIAL
STEEL SHEEi PILES 2100 SO.FT,
EXISTING FOOTING
El. 0.00'
1
EXISTING GALVANIZEO
STEEL PIPE PILE ITYP,I �
1
1
1
1
1
1
I
I
1
�
�
�
�
�
1
�
STREAM BED �
I
1
1
1
1
1
1
I
I
1
�
�
�
�
�
1
�
VIEW X-X
REVISED STREAM BED ELEVATION TO REFLECT
CURRENT ELEVATIONS. DRAWING U�'DATED BY B.L. JORDAN
04/26/2016
FOOiING
STEEI.
SNEET
PILE
EL.-26.00
BO7TOAA OF STEEI
StiEET PILE
PROJECT N0. 8-4028
BLADEN COuNTY
STAT ION� 29+02.50 -L -
•
�
t�
T����I
♦ � i����l
� ����i
T�����
1����1
I ����I
•����i
1����1
T����I
r����i
� ����i
. �����i
r�����
I ����I
*����i
1����1
T����I
■�����
1��G�1
T����I
� i����l
� ����i
• T����i
�����i
i ����i
*����i
1����1
T����I
6"
�Y �
ip I
%— �/ " 0 SOUARE
B�NO U BOLTS �,
(TYPJ E-
v
— STEEI �
REINFORCEMENT �''
6"X 6'GRIp m
t0
► �
i— CB x 11.5 �"),
(TYP.)
�i2-X �4-X 9-e
tTYP.)
I_..� - ' � ai
r
STEEL SHEET PILE MC 18X42.7
STEEL CHANNEL
COPING ITYP.)
PLAN
STEEI
REINFORCEMENT /— SUUARE BEND
6"x 6"GRID / U BO�T
C8 x i1.5 -�
'/2' X 14' x 9' Q
STEEL StEET PILE
DETAIL "E"
\
\
I �
� I�/ DETAIL '0'
I �
I �
1 �
/
\ �
� �
- MC 18X42.7
STEEI CHANNEI
COPING
STEEI SHEET
PIlES
PARTIAL VIEW 'Y'
'/2" 0 BOL T
h�—=�1
SOUARE BENO U BOLTS
( 8 REOLIIREO)
6 Y �
MC IBx42.7
C6 X iL5 STEEI Ct+A►�IEI �._
(TYP.) COPING � ��
� �
/
'/2"0 SOUARE SEE DETAIL "C' � �
BEND U BOlTS
tTYP.) �
�
STEEL �
STEEL SHEET '
REINFORCEMENT PILES �
6'x 6'GRIp I
%2" X 14" x 9" Q
(TYPJ I
�-MC l8X42.7
STEEI CHAN1�l
COPING <TYP.)
PLAN
STEEI St�ET PILE
�
1 �t AA1
ELEV. 6.00
El. -12.00s
STREAM BEO
� BOTTOM Of STEEL
� SMEET PiIE
ELEV.-26.00
SECTION THRU
STEEL SHEET PILE
.c .. ]4"x 9"e
`•_-HOIE FOR %z"0
OlTS (TYP.1
(TYP.) . .
ELEVATION
DETAIL "D"
9- e
NOTE:
All STEEL SNEET PILES SxA�L HAVE A MINIMUM SECTION
MOOULUS ON 30.2 in3/ft.
STEEI SHEET PIlES SHALL MEET ASiM A572 OR A690 SPECIFICATIONS.
STEEI. SHEET PIlES SttAll BE GAIVANIZEO IN ACCORDANCE WITH
SECTION l076 OF THE STANDARD SPECIFICATIONS.
FOR CRANE SAFETY,SEE SPECIAL PROVISIONS.
FOR SECURING Of VESSElS.SEE SPECIAI PROVISIONS.
AI.1. REIt�ORCING STEEI SHAII BE lMJC0ATE0 GRADE 60.
REINFORCING STEEI TO BE WEL�ED AT ALl INTERSECTIONS BETWEEN
TOP MAT AND BOTTOM MAT,
All STRUCiURAL STEEL AND PLATES SNALL BE AASNTO M270 GRAOE 50.
A1.I. BOITS. NUTS ANO WASHERS SHAI.1. COMPIY TO ASiM A325.
ALL STRUCTURAL STEEL.BOLTS.NUTS A1� WASHERS TO BE
GALVANIZEO.
- MC lBX42.7
STEEI CHANNEL
COPING
�ZY0 �N. S. BOLT$
T
STEEL SHEET PI�E
�ETAIL "C"
� $TEEI �Ii a1 tf. S. BOLTS (TYP,)
SH ET PILES
-- �- � ----�— - -�---
+ + + +
MC 18X42.T
STEEI. CHANNEI
COPING
PLAN VIEW
BILL OF MATERIAL
STEEL SHEET PILES 4330 Sa.FT.
STRUCTURAL SiEEL 4510 LBS.
STONE FILL t22 TONS
t•57 OR E�UIVAIENT)
6"THICK CONCRETE SLAB 3.0 CY
WITHWWF l2X 12-W4XW4
BAR N0. SIZE TYPE LENGTH WEIGHT
Bl 27 •6 STR 16'-6' 669
B2 66 •6 STR 4'-9" 471
REINFORCING STEEL LBS. 1140
PRO.JECT N0. B-4O28
BLADEN COuNTY
STATION3 29+02.50 -L-
C+
9QF` SEE DETAIL 'A'
F`
9�
��
� �
� �
D . �,.►.� SEE DETAIL
8"THICK CONCRETE SLAB � �'��
OVER STONE FILL ) D� D�' '. �v�1
J ' D ,- D• ' p ' �
p ' ' D /
f-J . ''.v : � v .� . '•'+
OUTSIOE EDGE � •D � ���
OP SUPERSTRUCTURE—� �� '. � � ,
�
�
._._._._.-L-.�—�
..
µ
� �.
�� ��♦
REINFORCEMENT � � � i �� � �
6"x 6"GRIO �� 1 \1
SEE OETAIL 'E' ; �� �� ;
♦ �� � �
, ♦ � ; ♦
MC 18X42.7 ♦ � ♦
STEEI CHANNEL ♦ (� � ♦
CaPING � � 1 � � s,
, ♦ i � �i ��
, ♦'�� �i�� :�♦
♦
��� C6 x tl 5
OUTSI�E E�GE J SEE DETAII '0' ITYP.> � �. /
Of $UPERSTRUCTURE ON $HEET 2 OF 2 �5�
`j.
�►. X ,'
�
PLAN
�ETAIL 'A'
0
�
EXISTINC
GALVANIZED
STEEL PIPE
PILE (TYP.I
7GAU VV�7IVCV I Vtt
i
6"iHICK CONCRETE SIAB
WITH WW- - -- - • - -- • -
COIT CONNECTOR
.T CONNECTOR STEEL S�ET aIIES
fEEL SHEET PILES
DETAIL 'B'
��
� �
STEEI
SNEET
PILE
EL.-32.00
BOTTOM OF STEEL
SHEET PILE
15'-7' • 5'-6" * 15'-0" •
EXISTING STEEL
CONCRE7E REINFpRCEMENT
COLUMN 6"X 6'CRIO
�TYP.� SEE OETAIL 'E'
r ��i r �� l'-3'
1'-10" sl 1 �._9. = 1 1
1 � 1 1 � 1
1 1 1 . 1
1 I 1 WORKLINE� 1! 1
1 I 1 I � 1 I 1
�---' -�-'-"-=� 9,�0„ �---' �-'- i
i � � I � �� i
� �� � '� T * �� � � 7'
1 1 1 1 1 1 1 1
1 I I 1 I 1 1 1
� � � � CS x IL5 � � � �
tTYP.I
� � � � � � � �
� � � � � � p � �
� � � � � � � �
� � � � � �� � �
I 1 1 1 1 I~ I 1
1 1 1 1 1 1 1 I
1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1
L 1 L� L 1 < 1
ExISTING GALVANIZED
• STEEL PIPE PILE (TYP.) �
c'S7 SIZE OR
EOUIVALENTI
SECTION Z-Z
EL. -26.00
BOTTOM Of STEEI
SHEET PIIE
VIEW X-X
EXISTING FOOTING tTYP,t
El. 8.00
TOP OF FOOTING
- MC 18X42.T
STEEL CFIA►�p1El
COPING �
r-
PRO�ECT Np. B-4028
BLADEN COuNTY
STAT IONa 29+02.50 -L -