HomeMy WebLinkAboutNC0085812_Compliance Inspection 2016_20160303 PAT MCCRORY Governor N a DONALD R. VAN DER VAART Secretary Water Resources ENVIRONMENTAL QUALITY S. JAY ZIMMERMAN Director March 3, 2016 RECEIVED/NCDEQ/DWR Mr. Richard D. McMillian, P.E. MAR 1 0 2016 Water &Wastewater Division Director 500 North Main Street, Suite 600 Water Quality Monroe, North Carolina 28112-4730 Permitting Section SUBJECT: Compliance Evaluation Inspection Grassy Branch WWTP NPDES Permit NC0085812 Union County, NC Dear Mr. McMillian: On March 3, 2016, Roberto Scheller of this Office conducted an inspection at the subject facility. This inspection was conducted as a Compliance Evaluation Inspection (CEI) to insure compliance with permit requirements and conditions. At the time of inspection facility appeared to be very well maintained and operated. It was noted that the subject facility experiences high flows due to inflow and infiltration. An inspection of the collection system was conducted by this Office on February 23, 2016 and will be addressed under separate cover. We wish to thank you and operating staff for your assistance regarding the inspection. A copy of this inspection will be forwarded to the facility's Operator-in-Responsible-Charge (ORC). The enclosed report should be self-explanatory; however, should you have any questions, please do not hesitate to contact myself of Roberto Scheller at (704) 235- 2204 or roberto.scheller@ncdenr.gov. Sincerely, ed;' W. Corey Basinger, Regional Supervisor Water Quality Regional Operations Section Division of Water Resources, NCDEQ Enclosure: Inspection Report cc: Danny L. Smith — ORC— Charlotte Water Dawn Padgett— Operations Manager—Charlotte Water Wastewater Branch MSC 1617 — Central files basement State of North Carolina I Environmental Quality I Water Resources I Water Quality Regional Operations Mooresville Regional Office'610 East Center Avenue,Suite 3011 Mooresville,North Carolina 28115 704 663 1699 United States Environmental Protection Agency Form Approved. EPA Washington,D.C.20460 OMB No.2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A:National Data System Coding(i.e.,PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 h 2 L 3 I NC0085812 111 12 I 16/03/03 117 18 19 LI I 201 2111 ( 111111111111111111111111111111111111111 p6 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA -------------------Reserved------------ 67 1 I 70 711 I 72 Lai 731 1 174 75I 1 1 1 1 1 1 180 LJ Section B:Facility Data 1 Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 10:02AM 16/03/03 13/12/01 Grassy Branch WWTP Exit Time/Date Permit Expiration Date Old Fish Rd 11:52AM 16/03/03 18/10/31 Monroe NC 28111 Name(s)of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Ill Danny L Smith/ORC// Name,Address of Responsible Official/Title/Phone and Fax Number Contacted Edward Goscicki,500 N Main St-Ste 500 Monroe NC 281124730/Public Works Director/704-296-4212/7042964232 No Section C:Areas Evaluated During Inspection(Check only those areas evaluated) 5 Flow Measurement 5 Operations&Maintenance • Records/Reports II Self-Monitoring Program Facility Site Review • Effluent/Receiving Waters Section D:Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s)and Signature(s)of Inspector(s) Agency/Office/Phone and Fax Numbers Date bertooScheller MRO WQ//252-946-6481/ `/ �, // Y c!V FO Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date W.Corey Basinger MRO WQ//704-235-2194/ EPA Form 3560-3 Rev 9-94)Previous editions are obsolete. �l(, Attsr-e 721441— 112-Q Page# 1 NPDES yr/mo/day Inspection Type 1 31 NC0085612 111 121 16/03/03 I 17 18 ILI Section D:Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) Page# 2 Permit: NC0085812 Owner-Facility: Grassy Branch WVViP Inspection Date: 03/03/2016 Inspection Type: Compliance Evaluation Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? • 0 0 0 Is all required information readily available,complete and current? • 0 0 0 Are all records maintained for 3 years(lab. reg. required 5 years)? • 0 0 0 Are analytical results consistent with data reported on DMRs? • 0 0 0 Is the chain-of-custody complete? • 0 0 0 Dates, times and location of sampling • Name of individual performing the sampling • Results of analysis and calibration • Dates of analysis • Name of person performing analyses • Transported COCs • Are DMRs complete:do they include all permit parameters? • 0 0 0 Has the facility submitted its annual compliance report to users and DWQ? • 0 0 0 (If the facility is=or>5 MGD permitted flow) Do they operate 24/7 with a certified operator 0 0 • ❑ on each shift? Is the ORC visitation log available and current? • ❑ 0 0 Is the ORC certified at grade equal to or higher than the facility classification? • 0 0 0 Is the backup operator certified at one grade less or greater than the facility classification? • 0 0 0 Is a copy of the current NPDES permit available on site? • 0 0 ❑ Facility has copy of previous year's Annual Report on file for review? 0 0 0 • Comment: Operations& Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? U ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable • 0 0 0 Solids, pH,DO, Sludge Judge,and other that are applicable? Comment: Bar Screens Yes No NA NE Type of bar screen a.Manual • b.Mechanical ❑ • Are the bars adequately screening debris? • 0 0 0 Is the screen free of excessive debris? • ❑ 0 0 Page# 3 Permit: NC0085812 Owner-Facility: Grassy Branch WWTP Inspection Date: 03/03/2016 Inspection Type: Compliance Evaluation Bar Screens Yes No NA NE Is disposal of screening in compliance? • ❑ 0 0 Is the unit in good condition? • ❑ 0 0 Comment: Equalization Basins Yes No NA NE Is the basin aerated? • 0 0 0 Is the basin free of bypass lines or structures to the natural environment? • ❑ 0 0 Is the basin free of excessive grease? • 0 0 0 Are all pumps present? • ❑ 0 0 Are all pumps operable? • 0 0 0 Are float controls operable? • 0 0 0 Are audible and visual alarms operable? • 0 0 0 #Is basin size/volume adequate? • 0 0 0 Comment: This facility is having issues with I&I. Aeration Basins Yes No NA NE Mode of operation Ext.Air Type of aeration system Diffused Is the basin free of dead spots? • 0 0 0 Are surface aerators and mixers operational? • 0 0 ❑ Are the diffusers operational? • 0 0 0 Is the foam the proper color for the treatment process? • 0 0 0 Does the foam cover less than 25%of the basin's surface? • 0 0 0 Is the DO level acceptable? • 0 0 0 Is the DO level acceptable?(1.0 to 3.0 mg/I) • 0 0 0 Comment: Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? • ❑ 0 0 Is the site free of excessive buildup of solids in center well of circular clarifier? • ❑ 0 0 Are weirs level? • 0 0 0 Is the site free of weir blockage? • ❑ 0 0 Is the site free of evidence of short-circuiting? • 0 ❑ ❑ Page# 4 Permit: NC0085812 Owner-Facility: Grassy Branch VWVTP Inspection Date: 03/03/2016 Inspection Type: Compliance Evaluation Secondary Clarifier Yes No NA NE Is scum removal adequate? • 000 Is the site free of excessive floating sludge? • ❑ ❑ ❑ Is the drive unit operational? • 000 Is the return rate acceptable(low turbulence)? • 000 Is the overflow clear of excessive solids/pin floc? • ❑ ❑ ❑ Is the sludge blanket level acceptable?(Approximately 1/4 of the sidewall depth) • 000 Comment: Disinfection - UV Yes No NA NE Are extra UV bulbs available on site? • ❑ ❑ ❑ Are UV bulbs clean? • 000 Is UV intensity adequate? ❑ ❑ ❑ • Is transmittance at or above designed level? 00D • Is there a backup system on site? • ❑ ❑ ❑ Is effluent clear and free of solids? • 000 Comment: UV was noted as being cleaned weekly. Effluent Sampling Yes No NA NE Is composite sampling flow proportional? ❑ ❑ • ❑ Is sample collected below all treatment units? • DOD Is proper volume collected? • 000 Is the tubing clean? • ❑ ❑ ❑ #Is proper temperature set for sample storage(kept at less than or equal to 6.0 degrees • 0 0 0 Celsius)? Is the facility sampling performed as required by the permit(frequency, sampling type • 000 representative)? Comment: Flow Measurement-Influent Yes No NA NE #Is flow meter used for reporting? • 000 Is flow meter calibrated annually? • 000 Is the flow meter operational? • 000 (If units are separated) Does the chart recorder match the flow meter? • 000 Comment: Page# 5 Permit: NC0085812 Owner-Facility: Grassy Branch WWTP Inspection Date: 03/03/2016 Inspection Type: Compliance Evaluation Flow Measurement- Influent Yes No NA NE Standby Power Yes No NA NE Is automatically activated standby power available? • 0 0 0 Is the generator tested by interrupting primary power source? • 0 0 0 Is the generator tested under load? • 0 0 0 Was generator tested&operational during the inspection? 0 0 0 II Do the generator(s)have adequate capacity to operate the entire wastewater site? • 0 0 0 Is there an emergency agreement with a fuel vendor for extended run on back-up power? • 0 0 0 Is the generator fuel level monitored? • 0 0 0 Comment: Page# 6