Loading...
HomeMy WebLinkAbout20160191 Ver 1_Revised Application_20160316Carpenter,Kristi From: Sent: Rivenbark, Chris Wednesday, March 16, 2016 7:53 AM To: Thomas Steffens (thomas.a.steffens@usace.army.mil); Ward, Garcy Cc: AI-Ghandour, Majed N; Chapman, Amy; Fritz Rohde - NOAA Federal; gary�jordan@fws.gov; Johnson, Jay B; Keith Hanson; Koch, Thomas K; Carpenter,Kristi; Mellor, Colin; Rouse, John W; Staley, Mark K; Staples, Shane; Thomas, Roger D; Wilson, Travis W.; Twisdale, John W; Wilkins, Ronald B; Cashin, Gordon E; Yamamoto, Brian F; Subject: Follow Up Flag: Flag Status: Kyle, Byron T; clarence.coleman@fhwa.dot.gov; Cynthia VanDerWiele; Joyner, Drew; Militscher, Chris (militscher.chris@epa.gov); Monte Matthews (Monte.K.Matthews@usace.army.mil); Tony Able (Able.tony@Epa.gov); Ayscue, Phillip W; Harmon, Beth; Feulner, Brett M; Griffin, Randy W; Paugh, Leilani Y Revised Permit Application for R-2250, Pitt County Follow up Completed The permit application for R-2250 has been revised. The electronic copy can be viewed/downloaded at https://connect.ncdot.�ov/resources/Environmental/ Chris Rivenbark Project Development & Environmental Analysis Natural Environment Section North Carolina Department of Transportation 919-707-6152 office crivenbark(cDncdot.qov 1598 Mail Service Center Raleigh, NC 27699-1598 1020 Birch Ridge Drive Raleigh, NC 27610 ; , �! r M � � Email correspondence to and from this sender is subject to the N.C. Public Records Law and may be disclosed to third parties. Transportation March 15, 2016 US Army Corps of Engineers Regulatory Field Office 2407 West St" Street Washington, NC 27889 Attention: Thomas Steffens NCDOT Coordinator Dear Sir: PAT McCR�RY Governar NICHOLAS j. TENNYSON Secretary Subject: Revised Application for Section 404 Individual Permit, Section 401 Water Quality Certification, and Neuse Riparian Buffer Authorization for the construction of the Greenville Southwest Bypass from south of Old NC 11 to US 264 in Pitt County. TIP No. R-2250 Reference: Section 404/401 Permit Application submitted February 25, 2016 As you are aware, the North Carolina Department of Transportation (NCDOT) proposes to construct a 123 mile controlled-access freeway facility on new alignment from south of Old NC 11 to US 264 (Stantonsburg Road) in Pitt County. NCDOT submitted a permit application for this project on February 25, 2016. Since that time, the potential impacts for the project due to borrow pit construction have been clarified. The purpose of this letter is to revise our permit application requests to include these borrow pit activities. As currently proposed, there are no permanent impacts to jurisdictional resources due to borrow aetivities. Skaggs drainage analyses were used to ensure no impacts to the jurisdictional resources adjacent to the barrow sites. There are 6 borrow sites: Jones, Steiner, Edwards, Murphy, Dail, and Moye. Only the Moye site is anticipated to have any impacts to jurisdietional resources. This site has an existing crossing of an intermittent channel. At this crossing, the existing 21-foot pipe will be extended to 40 ft. Widening this crossing will involve impacts to 1,440 sq. ft. in Zone 1 riparian buffers and 760 sq. ft. in Zone 2. This temporary stream crossing extension will be removed following the borrow activities and replanted. The original crossing will be left in place. Proposed permanent impacts to jurisdictional areas total 0.33 acre of permanent wetland impacts and 2,204 linear feet of permanent stream impacts, and these numbers remain unchanged. Enclosed you will find a revised Wetland Impact Summary sheet that includes 19 ft of temporary channel impacts at the Moye property and a revised Buffer Impact Summary sheet listing the allowable buffer impacts at the this site. �Nothing Compares� .� State of North Carolina I Department of Transportation I Project Development and Envirorunental Analysis 1000 Birch Ridge Drive I 1548 Mail Service Center I Raleigh, NC 27699-1548 919-707-6000 NCDOT requests that this information regarding the borrow site activities be incorporated into review of our existing application for Section 404, Section 401 and Riparian Buffer authorizations. A copy of this revised permit request and its distribution list will be posted on the NCDOT website at: https://connect.ncdot.�ovh•esources/Environmental Thank you for your assistance with this project. If you have any questions or need additional information, please contact Gordon Cashin at or (919) 707-6107. Sincerely, �` Roger Rochelle, P.E. Technical Services Administrator cc: NCDOT Permit Application Standard Distribution List L2] WETLAND PERMIT IMPACT SUMMARY WETLAND IMPA T URFA E WATER IMPA T Hand Existing Existing Permanent Temp. Excavation Mechanized Clearing Permanent Temp. Channel Channel Natural Site Station Structure Fillln Fillln in Clearing in SW SW Impacts Impacts Stream No. (From/To) Size / Type Wetlands Wetlands Wetlands in Wetlands Wetlands impacts impacts Permanent Temp. Design (ac) (ac) (ac) (ac) (ac) (ac) (ac) (ft) (ft) (ft) 1 23+g1 - 39+g3 -FLYBY7- ROADWAY FILL 0.14 < 0.01 1,532 92 2 26+p0 - 28+50 -Y7RPC- UTILITY RELOCATION 0.01 50 3 99+52 - 101+50 -L- 72" RCP-III 0.03 0.01 246 117 5 67+77 - 69+66 -Y9- 54" RCP-III 0.03 < 0.01 6 247+gg - 252+06 -L- 54" RCP-IV 0.08 0.02 7 436+30 - 437+g3 -L- 10' x 7' RCBC 0.05 0.06 233 244 8 638+38 - 639+g6 -L- ROADWAY FILL 0.33 9 39+16 - 41+02 -FLYBY7- 60" PIPE EXTENSION 0.02 < 0.01 132 38 10 54+55 - 55+7g -Y8- 96" CSP EXTENSION < 0.01 < 0.01 11 5+7g - 7+11 -Y18- 9' x 7' RCBC 0.01 0.01 61 59 MOYE PROPERTY' TEMPORARY CROSSING 19 TOTALS`: 0.33 0.37 0.14 2,204 619 0 'Rounded totals are sum of actual impacts NOTES: SITE 1 PROPOSED STREAM RELOCATION: 1,914 FT. SITE 4 HAS BEEN ELIMINATED 'BORROW SITE LOCATION � BUFFER IMPACTS SUMMARY IMPACT BUFFER TYPE ALLOWABLE MITIGABLE REPLACEMENT ROAD PARALLEL ZONE 1 ZONE 2 TOTAL ZONE 1 ZONE 2 TOTAL ZONE 1 ZONE 2 SITE NO. STRUCTURE SIZE / TYPE STATION (FROM/TO) CROSSING BRIDGE IMPACT (ftZ) (ftz) (ftZ) (ftZ) (ftz) (ftZ) (ftZ) (ftZ) 1 ROADWAY FILL 23+g1 - 39+93 -FLYBY7- X 89,889 60,675 150,564 2 UTILITY RELOCATION 26+00 - 28+50 -Y7RPC- X 806 806 7,825 7,825 3 72" RCP-III 99+52 - 101+50 -L- X 17,579 12,145 29,724 5 54" RCP-III 67+77 - 69+66-Y9- X 8,453 5,414 13,867 7 10' x 7' RCBC 436+30 - 437+83 -L- X 6,557 4,476 11,033 15,578 10,057 25,635 9 60' PIPE EXTENSION 39+16 -41+02 -FLYBY7- X 12,010 5,172 17,182 10 96" CSP EXTENSION 54+55 - 55+79 -Y8- X 4,619 3,095 7,714 11 9' x 7' RCBC 5+78 - 7+11 -Y18- X 3,261 4,934 8,195 TEMPORARY CROSSING MOYE PROPERTY* X 1,440 760 TOTAL: �,997 6,042 11,839 159,214 101,492 260,706 NOTES: SITE 1 PROPOSED STREAM RELOCATION: BUFFER ZONE 1: 1.29 AC BUFFER ZONE 2: 0.87 AC "BORROW SITE LOCATION Rev. May 2006