Loading...
HomeMy WebLinkAboutSW8141101_Approved Plans_20150115 EYP Architecture & Engineering, PC 811 West Hargett Street YP / Raleigh, NC 27603 Tel: 919 833 8818 Fax: 919 833 6898 eypae.com CONSULTANTS: Structural Engineering: COUNTY OF BRUNSWICK Stewart Engineering, Inc. 421 Fayetteville St., Suite 400 Raleigh, NC 27601 Tel: 919 380 8750 74/76 Fax: 919 380 8752 ICK� C .�� � Civil Engineering/ Landscape Architecture: A� Cole Jenest & Stone, pa jjh t 1 /► 119 East Hargett Street, Suite 300g� �' Raleigh, NC 27601 AMW �,1 1 Tel: 919 645 5964 r Fax: 919 719 1819 C� �001 / Plumbing Mechanical Electical & Fire Protection: Q 1� / II T 133 EYP, Inc Q S ! l �S / / 420-I-A The Parkway / Greer, SC 29650 Al WA 131) 1787Tel: 864 334 0997 Fax: O SIT 1 211 R?OR, 15 2 SEAL SR , \ J z C103 904, HPARCEL ID = : 152004201 PARTIAL CA PIN #. 212.000354259 (PARTIAL) VICINITY MAP (Not to Scale) COMMUNITY S RVIC L ARNING C NT R ' 8 INDEX OF SHEETS 1 REVIEW COMMENTS 06111114 OWNER 2 BID DOCUMENTS 07102114 STATE OF NORTH CAROLINA TYPE OF WORK: C000: COVER SHEET 3 ADDENDUM 1 07/25/14 116 W. JONES STREET C101 : EXISTING CONDITIONS/DEMOLITION PLAN 4 REVIEW COMMENTS 07/31/14 RALEIGH, NC 27699 THE EAST CAROLINA SCHOOL OF DENTAL MEDICINE PROPOSES TO CONSTRUCT A SERVICE LEARNING CENTER (SLC) ON A C201 : STAKING AND MATERIALS PLAN 5 NCDENR EROSION CONTROL 10106114 PHONE (919) 807-2425 SITE IN BRUNSWICK COUNTY. THE SLC WILL BE AN OPERATING DENTAL CLINiC AND DEVELOPED USING A PROTOTYPICAL C301 : EROSION CONTROL STAGE � PLAN 6 NCDENR STORMWATER 11/14/14 8,000 SF BUILDING WITH ASSOCIATED PARKING TO ACCOMMODATE APPROXIMATELY 35 VEHICLES. C302: EROSION CONTROL STAGE 1 PLAN ' ," . , ' //� .. C303: EROSION CONTROL STAGE 2 PLAN C304: EROSION CONTROL STAGE 3 PLAN " a s ' °` , \ kcr WAM 1RftrWAX 5 " " # Revision Date GRADING AND DRAINAGE PLAN C—LD APPLICANT 4� "Aa mow // \ C402: GRADING AND DRAINAGE PLAN SCO ID#; 07-07054-02J EAST CAROLINA UNIVERSITY 4 ' , / .`' \� C403: PRE AND POST DEVELOPMENT DRAINAGE CONDITIONS 1001 E. FOURTH STREET ' GREENVILLE, NC 27858 i �� \� •. v ,> \ C501 : WATER DISTRIBUTION AND SANITARY SEWER PLAN PHONE (919) 328-6858 � � "�....,_ � �,,,� � � \ 2 \ C601 : PLANTING PLAN %�M J e C701 . SITE DETAILS C702: SITE DETAILS SURVEYOR DESIGNER , CommunityService s p F PPS GREG A. WAYNE, PLS COLEJENEST & STONE, P.A. v C703: SITE DETAILS APPROVED �,�,, ��.. � �� � \ � . .�# � � � ,� gym_ Learning Center #8 T HARGETT ST. STE 300 r w� � - NORTH CAROLINA ENVIRONMENTAL g HANOVER DESIGN SERVICES, P.A. 119 EAST , y ism/ C704: SITE DETAILS MANAGEMENT COMMISSION 1123 FLORAL PARKWAY RALEIGH, N.C. 27601 Brunswick C705: SITE DETAILS WILMINGTON, N.C. 28403 PHONE (919) 719-1800 � " t.,g -SIV East Carolina University PHONE (919) 343-8002 FAX (919) 719-1819 i g�� � -' �� � " ��� n C706: SITE DETAILS School of Dental Medicine FAX (910) 343 9941 1101 : IRRIGATION PLAN f Brunswick County NC 1102: IRRIGATION DETAILS ENGINEER'S CERTIFICATION OF COMPLIANCE WITH BRUNSWICK COUNTY SPECIFICATION AND DETAILS" NUMBER DATE BY REVISION DESCRIPTION I HEREBY CERTIFY THAT THE PLANS, DETAILS, AND ASSOCIATED PROJECT SPECIFICATIONS COMPLY WITH THE LATEST VERSION, AS OF THIS DATE: 07/02/2014 DATE, OF BRUNSWICK COUNTY'S STANDARD SPECIFICATIONS AND STANDARD DETAILS PER STANDARD ENGINEERING PRACTICE. FURTHERMORE, SCALE: As indicated EYP PROJECT NO.: 6013031.01 1 CONFIRM MY UNDERSTANDING THAT REVIEWS AND APPROVALS BY BRUNSWICK COUNTY PERSONNEL DO NOT IMPLY' THAT BRUNSWICK COUNTY PERSONNEL_ HAVE REVIEWED AND ARE IN AGREEMENT WITH EVERY PORTION OF THE PLANS AND SPECIFICATIONS THAT I HAVE SUBVITTED. I UNDERSTAND THAT BRUNSWICK COUNTY REVIEWS AND APPROVALS ARE MEANT TO ENSURE THAT THE OVERALL PLANS ARE IN GENERAL COMPLIANCE WITH COUNTY OBJECTIVES. I UNDERSTAND THAT IT IS MY FULL RESPONSIBILITY TO ENSURE THAT PLANS AND SPECIFICATIONS DESIGNED BY: AWK ARE IN FULL COMPLIANCE WITH APPLICABLE COUNTY, STATE, FEDERAL, AND OTHER MUNICIPAL REQUIREMENTS. ADDITIONALLY, I UNDERSTAND DRAWN BY: . APPROVAL STATUS DATE BY DEPARTMENTEGE THAT THE COUNTY WILL NOT ASSUME OPERATION, MAINTENANCE, OR OWNERSHIP OF CONSTRUCTED FACILITIES THAT DO NOT MEET COUNTY CHECKED BY RTF PLANNING REQUIREMENTS AND THE COUNTY MAY REFUSE TO ISSUE PERMITS AT FACILITIES THAT THE COUNTY DEEMS ARE NON—COMPLIANT \A ITH t ❑ YES ❑ NO El N/A COUNTY SPECIFICATIONS. I ALSO CONFIRM MY UNDERSTANDING THAT COUNTY INSPECTIONS ARE FOR THE SOLE USE OF THE COUNTY AND I ❑ YES ❑ NO ❑ N/A ENGINEERING11 CERTIFY THAT I WILL NOT USE OR DIRECT OTHERS TO USE COUNTY INSPECTIONS FOR STATE COMPLIANCE PURPOSES OR ANY OTF-ER Y ❑ YEs ❑ No ElN/q PUBLIC UTILITIES � � ---�' PURPOSE." COVER SHEET C000 0 3&03 EYP Architecture & EXISTING TREE TABLE �,, ��, � � � f` Engineering, PC t' 811 West Hargett Street No, SIZE TYPE QQ Ili EYP / Raleigh, NC 27603 �S Tel: 919 833 8818 u7,86 ? Fax: 919 833 6898 2003 17 pine EXISTING WETLANDS 2005 13„ pine °•, _ _--- _ ,07 �� sR eypae.com 2006 10 sweet gum rs 2007 12" maple TRACT B ` 2008 14" pine MAP CABINET 48 PAGE 33 SIT J� �I CONSULTANTS: BOOK 2698 PAGE 808 2009 13" pine Structural Engineering: 2010 13" pine C-LJ �°�"� SR 1502 P PROPOSED CURB INLET Stewart Engineering, Inc. 2012 12" gum BY OTHERS (CI#75) t2011 15" 421 Fayetteville St., Suite 400 038,07 2013 14" pine RINV.3s 06 Raleigh, NC 27601 2014 14" pine , / i Tel-el- 919 380 8750 2015 13" pine " 2015 12" hickory PROPOSED CURB INLET '� � Fax: 919 380 8752 BY OTHERS (CI#74) 7, r.d� 3 , 3 VICINITY MAP N.T.S. 2017 15" pine RIM: 39.24 e, � � �y Civil Engineering/ Landscape Architecture: 2018 17 Pine INV: 35.84 , 2019 12 pine � ,� � �' �% TOPOGRAPHICAL AND BASE SURVEY INFORMATION OBTAINED FROM Cole Jenest &Stone, pa �� 7 HANOVER DESIGN SERVICES, P.A.. THIS INFORMATION WAS ORIGINALLY 119 East Hargett Street, Suite 300 2020 20 maple . FUNSTON PARTNERS & CAMERON ISSUED AND SEALED BY GREG A. WAYNE; NORTH CAROLINA 2021 12" pine PROPOSED STORM DRAIN °° C 1\ A I.S. PROPERTIES, LTD PROFESSIONAL LAND SURVEYOR SEAL: L-2876, ON JULY 2, 2013. Raleigh, NC 27601 2022 16" pine IMPROVEMENTS BY OTHERS ' -Albs DB 2614 PG 989 PROPOSED IMPROVEMENTS FOR BRUNSWICK MEDICAL CENTER PARKWAY Tel: 919 645 5964 2023 12" pine , � «� , PB 48 PG 34 SHOWN PER PLANS FOR "BRUNSWICK NOVANT MEDICAL CENTER ROADWAY P N ♦ Fax: 919 719 1819 2024 13" pine g8 EXTENSION PROJECT," PREPARED BY SITE SOLUTIONS, P.A., DATED 2025 18" pine C-LD FEBRUARY 21, 2014 Plumbing Mechanical Electical & Fire Protection: 2036 17" pine 320°, 30, - I.S a sue , EYP, Inc 2037 16„ pine '" ♦ ., ���, 420-1-A The Parkway 2038 13 pine G� o ; ♦ ,%-"� �As '.,� LEGEND Greer SC 29650 2039 17" pine u�j�'-�i F�9 SYMBOL DETAIL Tel: 864 334 0997 2040 13" pine .y s F `�� ,- Fax: 2041 15" pine F� �R 2042 14" pine '�• TRACT e BRUNSWICK COUNTY HOSPITAL, LLC \, g TRACT A -- �� 2045 14 um � s � � MAP CABINET 48 PAGE 33 � PROPERTY LINE -/- BOOK 2698 PAGE 808 R 2046 12 gum MAP CABINET 48 PAGE 33 BOOK 2751 PAGE 709 I.S. 2047 14 pine � � LD �� F, ..• T� _ ,moo : FEssioC ''•.2 - C-LD �`' ``�? oRppRq� = .gyp ' ' PROPOSED 12" WATER LINE I.S. § W '• SEAL 1361 4C�c e - - PROJECT PROPERTY LINE -/- J : y Q 0 c 5 BY OTHERS wf p o c-�o3�z •-L CA?0 EXISTING TREE �� ��I , TO•.�D .•\� PROPOSED PRIVATE"; STREET � TO BE REMOVED, TYP. EXISTING PRIVATE ACCESS, IUTILIT` DRAINAGE EASEMENT "PHYSICIANS �`� , �� EXISTING CONTOUR PLAZA DRIVE" �� �° J - � j� �' � 0/06 1 MAP CABINET 48 PAGE 33 c�• PROPOSED 8" SANITARY Cj SEWER EXTENSION BY OTHERS � ����'/ o � � ° ,"' 9 - PROPOSED CONTOURS BY OTHERS -/- ��EXISTING SSMH PROPOSED CURB INLET ���Q � BY OTHERS (CI#73) z, RIM: 40.10 c Q INV: 33.12 RIM: 40.21 INV: 35.33 � EXISTING SAN. SWR. LINE AND MANHOLE -/- �.� PROPOSED CURB INLET ° 025 BY OTHERS (CI#72) � ~ �`A - 1 REVIEW COMMENTS 06111114 1 RIM: 41.07 � , ��� $ o PROPOSED CURB INLET INV: 34.90 ' E EXISTING UNDERGROUND ELECTRIC LINE / fi o �0 2 BID DOCUMENTS 07102114 BY OTHERS (CI#61) 39,11 - - _ _ _ EXISTING 8" C,`�'I °'j RIM: 39.95 D. _ INV: 34.32 SANITARY SEWERF sue. 3 ADDENDUM 1 07/25/14 ® EXISTING TREE TO BE REMOVED -/- 4 REVIEW COMMENTS 07/31/14 l w 0� 5 NCDENR EROSION CONTROL 10106114 39,27 ..w j � I � i 013 a \ 4 / W25 \ \ \ \ _ .._ O ,? '` =� _ .�" EXISTING WETLAND 6 NCDENR STORMWATER 3 11/14/14 .µ ' t P , 38,93 \ A3& 01 . G.�,"", -.., EXISTING GAS LINE -/- p w � o/ ..W,.w K 4 L-I0 . s7 05 f L� , / /_ \\ ,• / FO EXISTING FIBER OPTIC # Revision Date / N:104187.03 z2019PROPOSED CURB INLET o $ / 381BY OTHERS (DI#72A) i / F(� / E:22:25054.47 \ 7 \ ,. .,...,,, \\'" � � 4 . 0 � RIM: 38.85 "'� N.A.ID. 1983 PROPOSED CURB INLET \ \ - / f r.. INV: 35.71 BY OTHERS (CI#61A) s % . / E.I. (CONTROL) NOTES' SCO ID#. 07-07054-02J RIM: 39.95 \ \ ,\ / 00 INV: 36.20 { .M / o`' TELEGRAPH COMPANY \ ° EXISTING 12 1. CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION AND SEQUENCING OF \ 18 / \ •33 ;';:;` WATER LINE �' AMERICAN TELEPHONE AND 9 DEMOLITION AS DESCRIBED BY THESE DOCUMENTS AND SPECIFICATIONS. EXISTING POWERLINE \ / �� 3945 O � � / � � � � 20'EASEMENT D.B. 719 PG. 1049 � CONTRACTOR IS TO OBTAIN ALL PERMITS. EASEMENT r k \ 9 / OZO$ 2. CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF DEMOLITION OR RELOCATION WITH APPLICABLE UTILITY COMPANIES, IE, GAS, CABLE, POWER, EXISTING SSMH / ' - �0 tl0 Arl'S2 TELEPHONE, WATER, SEWER, ETC. SA RIM: 40.54 W INV: 32.72 j / a 3. CONTRACTOR SHALL BE RESPONSIBLE TO IMMEDIATELY FIX ANY ACTIVE t „ ,.,.,. EXISTING FIRE HYDRANT 00 '7via UTILITIES DAMAGED DURING CONSTRUCTION AT CONTRACTOR'S EXPENSE. s s�.., 39.E 4. ALL MATERIAL GENERATED BY THE DEMOLITION WILL BE HAULED FROM THE ■ �� O ,52 ids �`S E £ `*.,«,� � „ s v tea, ' SITE AND DISPOSED OF PER LOCAL ORDINANCES. Community Service EXISTING GAS LINE r` EXISTING FIBER OPTIC ENT EXISTING GAS EASEM / I :; / / LINE TO REMAIN 5. SAW-CUT CONCRETE AND ASPHALT PAVEMENT, SIDEWALK OR CURB AND GUTTER BEFORE EXCAVATION WHERE CONSTRUCTION PLANS SHOW TIE-INS. Learning $ H 'h PROTECT IN PLACE Center #8 #J47 1 / �9 6. BRUNSWICK MEDICAL CENTER PARKWAY SHALL REMAIN OPEN AND BRUNSWICK COUNTY ,� - ~ E.C.M. B ru n swi c k HOSPITAL, LLC MAP CABINET �;� , � gg �` l! UNOBSTRUCTED TO TRAFFIC AT ALL TIMES. 48 PAGE 33 TRACT A BOOK I I \ ' / < 00 2751 PAGE 709 "� f , ' 5 12 7. CONTRACTOR IS RESPONSIBLE FOR TRAFFIC CONTROL DURING CONSTRUCTION. East Carolina University 40,16 I School of Dental Medicine-LDI I ;j j '�" 35 0 JOHN C. CABLE PROPOSED 40' ACCESS G1a I l .-�" �3g•8 AND UTILITY EASEMENT I I ;"'I ' �" I- 39 6&,-- a, �2 Zq" `N PROPOSED DROP INLET A ff* Brunswick County NC BY OTHERS (DI#726) RIM: 38.85 C-Lu' 44 © � INV: 36.16 PROPOSED SIGN<.GE fi '�' . v EASEMENT AREA I �" � E.I. CONTROLTRACT B BENCHMARK ELEV. 40.46 MSL M,BOOK CABINET2698 P GE 808 3 �"�`� ► I � DATE: 0710212014 I I -,a ©ss �� SCALE: As indicated J--# C1.09- EYP PROJECT NO.: 6013031.01 � j I 40.59 � `� I ► c V JGw MUST������ via � o 0 4 1 4 ,76 LU .. -1W D m DESIGNED BY: AWK I DRAWN BY: CHECKED BY: RTF 13 BEFORE YOU DIGI `� CONTACT ONE-•CAIL CENTER , 4 1-800-632-4!99 l F i 1 1 $ CURVE RADIUS ARC CHORD CHORD BEARING DELTA ANGLE 1. CONTRACTOR IS FULLY RESPONSIBLE FOR CONTACTING APPROPRIATE PARTIES C1 570.00' 1 13.32' 1 13.14' N 13*24'51 " E 1 1'23'28" AND ASSURING THAT EXISTING UTILITIES ARE LOCATED PRIOR TO CONSTRUCTION. 122 2 N 33'56'55" E 29'40'40" --- C2 570.00 295.25 91 .96 1 i I 46 C3 55.00' 43.58' 42.45' S 46'10'41 " E 45'24'12" 2 ETC.TASCNOECEI SARYPOOSINSURELE OSAFETYINGO THE PUBLIC. USING FLAG MEN, EXISTING I CONDITIONS / 4ba 3. ALL PAVEMENT CUTS, CONCRETE OR ASPHALT, ARE TO BE REPLACED N C 101 I I ii LINE BEARING DISTANCE ACCORDING TO STANDARDS OF THE NORTH CAROLINA DEPARTMENT OF SCALE: 1" = 30' I I 1 L1 S 2328 .,5 E 12.36 , TRANSPORTATION. DEMOLITION I 1 � 4a 4. SHORING WILL BE ACCORDING TO OSHA TRENCHING STANDARDS PART 1926 0 15 30 60 PLAN SUBPART P, OR AS AMENDED. ,� / ZONING CODE SUMMARY / EYP Architecture & PROJECT NAME: ECU SCHOOL OF DENTAL MEDICINE SERVICE LEARNING CENTER #8 - BRUNSWICK COUNTY, NC // Engineering, PC TAX PARCEL: 1520004204 � / 811 West Hargett Street YP / Raleigh, NC 27603 ADDRESS: 100 BRUNSWICK MEDICAL CENTER PARKWAY NE, BOLIVIA, NO 28422 Tel: 919 833 8818 STATE OF NORTH CAROLINA / / / OWNER: / Fax: 919 833 6898 116 W. JONES STREET a s' // £T / 3 SR eypae.com RALEIGH, NO 27699 / / IS 919.807.2425 3r 12' WIDE GRAVEL / SIT 01 CONSULTANTS: MAINTENANCE ACCESS APPLICANT: -- PATH; SEE GRADING / EAST CAROLINA UNIVERSITY AND DRAINAGE PLAN / '� / Structural Engineering: 1001 E. FOURTH STREET ' / / SR 1502 GREENVILLE, INC 27858 / ' . T< / / Stewart Engineering, Inc. 252.328.6858 / # f 421 Fayetteville St., Suite 400 DESIGNER: JURISDICTION: BRUNSWICK COUNTY // j;, / // Raleigh, NC 27601 COLEJENEST & STONE, PA. STORIES: 1 Tel: 919 380 8750 150 FAYETTEVILLE ST., STE 950 GROSS FLOOR F.REA: 7,800 SF / �j / N RALEIGH, NC 27607 NUMBER OF UNITS/SUITES: 1 / // Fax: 919 380 8752 919.719.1800 VICINITY MAP N.T.S. TRACT B \ ' �' /� // Civil Engineering/ Landscape Architecture: MAP CABINET 48 PACE 33 / ZONING: CLD (COMMERCIAL - LOW DENSITY) ROOK .2698 PACE 808 \ / TOPOGRAPHICAL AND BASE SURVEY INFORMATION OBTAINED FROM Cole Jenest & Stone, pa PROPOSED USE: DENTAL CLINIC (MEDICAL FACILITY), PERMITTED (P) 4 // HANOVER DESIGN SERVICES, P.A.. THIS INFORMATION WAS ORIGINALLY BUILDING HEIGHT: 25' - ISSUED AND SEALED BY GREG A. WAYNE; NORTH CAROLINA 119 East Hargett Street, Suite 300 LOT COVERAGE: 11.14% LD , .,. // PROFESSIONAL LAND SURVEYOR SEAL: L-2876, ON JULY 2, 2013. Raleigh, NC 27601 LOT SIZE: 2.32 ACRES xi PROPOSED IMPROVEMENTS FOR BRUNSWICK MEDICAL CENTER PARKWAY Tel: 919 645 5964 SHOWN PER PLANS FOR "BRUNSWICK NOVANT MEDICAL CENTER ROADWAY Fax: 919 719 1819 SETBACK REQUIREMENTS: 4 / EXTENSION PROJECT," PREPARED BY SITE SOLUTIONS, P.A., DATED FRONT: 25' / FEBRUARY 21, 2014 Plumbing Mechanical Electical & Fire Protection: REAR YARD: 6' EYP, Inc SIDE YARD: 10' MIN (22' TOTAL) / 420-I-A The Parkway PROJECT BUFFERS: N/A (PER ZONING) � / LEGEND Greer, SC 29650 STREET BUFFERS: AS SHOWN SIGHT TRIANGLE 10' X 70', TYP. / R.1 9;5' TYP. Tel: 864 334 0997 SYMBOL DETAIL PARKING DATA: / FNSTON PARTNERS CAMERON Fax: MEET AND MATCH CURB � ll BRUNSWICK COUNTY UNIFIED DEVELOPMENT ORDINANCE ii� x PROPERTIES, L CURB INSTALLED BY OTHERS ` D REQUIRES 1 SPACE/250 SF. OF FLOOR AREA / TRANSITION 2'-6" CURB \ DID 2614 PC 989 PS 48 PO 34. PROPOSED SIDEWALK 8/C701 �����unn►p� REQUIRED: 7,800 SF (PHASE 1) = 32 SPACES ' AND GUTTER TO 1 -6' /////O41 ����� CA ,;: 3,500 SF (PHASE 2) = 14 SPACES , 1 CURB AND GUTTER AT 1''���/ & ���i�' ���` (N,•......R0� PROVIDED: 33 REGULAR SPACES (PHASE 1) / RADIUS POINT, TYP ���� F,S ,......STD-= ��`p�;:'F ES /0'•. 13 REGULAR SPACES (PHASE 2) �� BOTH SIDES �� 4 o�L?OR �•, ` ?.:�� 'L�'•.y HANDICAP: REQUIRED: 2 FOR 46 TOTAL REGULAR SPACES / SEE DETAIL 9A/C701LD C - - - ' SEAL F : PROPOSED ACCESSIBLE RAMP 7/C701 J j C 1361 PROVIDED: 2 (BOTH INSTALLED DURING PHASE 1) �,%O / A�� ' _ O :yo C-103 ��.:� " � LOADING SPACE: ` �T � /T'Q gyp.\ �� "� �v CARS �� C� � •' C-DcyG' / `S`ip y /�tl ',� G NEF':���`I` REQUIRED: 1 SPACE (12'X35') SF'li � -w �� �/\ ���II// ///�� �'�i ODD •F ���`�� F�yT / 9p Q TRACT B PROPOSED ACCESSIBLE VAN SPACE -/- ' %�10/06/14 BRUNS CK COUNTY HOSPITAL, LL C �`� � 1 � � \ AP CABINET 4B PAGE 33\ VAN TRACT A `° / BOOK 2698 PAGE 808 , AP CABINET 48 PACE 33 BOOS 251 PACE 709 „i ACCESSIBLE PARKING\ z / 1'53'43"W R:10, TYP. AND SIGNAGE .° 6.84 �� A PROPOSED ACCESSIBLE SIGN 12/C701 C-LD 04,Xz, ACCESSIBLE RAMP �« 11-�­­111- R:10' SEE DETAIL 7/C701 / \ L=64 7 R=50 0 '� / �, cs (4) BOLLARDS S� PROPOSED STOP SIGN _ ` - / L=0.45, R=513.00 HEAVY DUTY ASPHALT 2 AT EACH DUMPSTER ' SEE NOTE 7 BELOW -/ 13 FUTURE PARKING a AT DRIVE AISLES, TYP. SEE DETAIL 14/C701 # L_25.11 , R 513.00 SPACES, TO BE 25'x26' DUMPSTER PAD LOADING CONSTRUCTED WITH ,�. AREA �G' FUTURE EXPANSION 8 LF FLUSH -`- NSB� �, W/ HEAVY DUTY CONCRETE; REVIEW COMMENTS 06111114 CURB SEE 2 SEE DETAIL 4 C701 / (PHASE 2) I DETAIL 98/C701a�a� 0 / HEAVY DUTY CONCRETE 4/C701 9. ��w ` ,i " ... �o '\ 8' WOODEN SCREENED 2 BID DOCUMENTS 07/02/14 INSTALL SIGN READING, < �- R:10 "LOADING ZONE - NO d. ,PAP / IKE RACK O " FENCE AND GATE SET 1' 3 ADDENDUM 1 07/25/14 O ? �i • INSIDE PAD AREA IDLING" Q� ,' OWNER FURNISHED o SEE DETAIL 1/C703 p _? CONTRACTOR INSTALLED ; :" R:7' HEAVY DUTY BITUMINOUS CONCRETE 1B C701 4 REVIEW COMMENTS 07/31/14 PROPOSED MONUMENT SIGN BY � Q ��p r` SEE DETAIL 11/C701 NOSE DOWN CURB AT -� / OTHERS; CONTRACTOR TO o / = I ,..., : 8 DUMPSTER PAD, TYP. PROVIDE ELECTRICAL SERVICE �� RADIUS CURB AT 4 „ "'• - 0 5 NCDENR EROSION CONTROL 10/06/14 PER ELECTRICAL PLAN y DROP OFF PROPOSED MAILBOX; OWNER �� ^ 6 NCDENR STORMWA TER 11114114 7 T3 dj•, STANDARD DUTY BITUMINOUS CONCRETE 1A C701 FURNISHED, CONTRACTORS / f �5 . / EXISTING GAS INSTALLED; CONFIRM FINAL 26.5 LF FLUSH EASEMENT LOCATION WITH THE LOCAL CURB SEE tiesA " t \ a, POSTAL SERVICE DETAIL 6/C701 Q z RECYCLE,' CP �• O s/', f� ' J� �% .` . ,moo " ^� �s� \ PROPOSED V-6" CURB & GUTTER 3/C701 1I , / TRASH �`t���� �� _ O N C.'����� BENCH \ 12 .. < # Revision Date _ _SS CURB 6 OR 9B/C701 Al p & CUTTER, TYP �.. A � �� - SCO I D#. 07-07054-02J . , °\. STAKING AND MATERIALS PLAN NOTES LIGHT DUTY ASPHALT 1. SEE ARCHITECTURAL PLANS FOR BUILDING DIMENSIONS. � � � `<C � O rya �r� Q' � AT PARKING BAYS, TYP. V N58'29 07 W `' O p� 2. ALL DIMENSIONS ARE AT 90 DEGREES UNLESS OTHERWISE NOTED. ....... Ov Cf Q�� 6' CONCRETE �/ O �r / SIDEWALK 3. CONTRACTOR SHALL ESTABLISH AND VERIFY POINT OF BEGINNING ;,,•,;v7 -„ .r0 „ ' h0 �O�w (P.O.B.) AND STAKE SITE AS INDICATED ON CONSTRUCTION DOCUMENTS ;; U �^ PRIOR TO COMMENCEMENT OF CONSTRUCTION. NOTIFY COLEJENEST & //0\ M, \ 1 �O .' Nz ,� ' ♦ STONE, P.A. IMMEDIATELY OF ANY DISCREPANCIES. ,,, < OJ e QQ Q po / N'104187,03 %%% W/%//10/0i'ij//j� \ �».�„ ``,../ / '�" ` � ;._ 1 ,,::•:::":•:�1►dP �l/�<C/ ,� ' ' !v� / �„�°.« / � �°"� E<2225054,47 4. ALL DIMENSIONS ARE TO BACK OF CURB, FACE OF BUILDING, OR CENTERLINE UNLESS OTHERWISE NOTED. \ \ \ \ ��,,}/ � \ 1 � ' • 1 �,,..^,.�� N31 30'53"E / � /j E.I. (CONTROL) ° / / �1 - O / ( w„� 5. ALL DETAILS SHALL BE CONSTRUCTED IN STRICT COMPLIANCE WITH \ ' "1 PR /� ♦ SPECIFICATIONS AND CONSTRUCTION DOCUMENTS.t Community Service >v. .. ♦ TELEGRAPH COMPANY \ �" " , s t �, �` '°1 6 / AMERICAN TELEPHONE AND 6. ALL RADII SHALL BE 3'-6 B.O.C. UNLESS OTHERWISE NOTED. \ N6 8 Sy // ♦ 20'EASEMENT D.B. 719 PG. 1049 EXISTING POWER 8S2 -" O FTe / ♦ 7. STOP SIGNS SHALL BE R1-1 30"x30". Learning Center #8 EASEMENT �� 1' �♦ 80 8. ALL PAVEMENT MARKINGS SHALL BE LATEX PAINT. Brunswick / c3 ACCESSIBLE �` 28 �• ' � '° / ♦ 4 ' 9. CONTRACTOR SHALL PROVIDE TRAFFIC CONTROL AT BRUNSWICK MEDICAL MEET AND MATCH CURB i 1 '4" RAMP CURB INSTALLED BY OTHERS CENTER PARKWAY PER NCDOT STANDARDS. f � - =�� ��• � East Carolina University 'k 0 6" NO. 5 WASHED TRANSITION 2'-6' STONE FILL AT SITE FURNISHINGS School of Dental Medicine CURB AND GUTTER TO "-� �' EQUIPMENT PAD 1. SITE FURNISHINGS TO BE FURNISHED BY EAST CAROLINA UNIVERSITY, AND 1'-6" CURB AND / / N68'52'46"W y ��,. / SURROUND INSTALLED BY CONTRACTOR: (1) BENCH, (3) BIKE RACKS, (1) TRASH GUTTER AT RADIUS / d � Brunswick County NC 19.02 ♦ PROPERTY LINE RECEPTACLE, & (1) RECYCLING RECEPTACLE.4 N POINT. \ / SEE DETAIL 9A/C701 / R:10', TYP. 2. CONTRACTOR TO COORDINATE SITE FURNISHING LOCATIONS WITH LANDSCAPE SICK COUNTS 5 \ EC MASONRY SCREEN WALL ARCHITECT AND EAST CAROLINA UNIVERSITY PRIOR TO INSTALLATION. C NAP CABINET l �• ° .,; ....�. REFER TO ARCHITECTURAL TRACT A BOOK I I $ I / �, ♦ 2 PLANS FOR DETAILS I / / BUILDING TIE LINE LD _ �� TO COLUMN A10 FLOODPLAIN NOTE 07/02/2014 DATE: I / / / '`�� NO WATERCOURSE OR 100 YEAR FLOODPLAIN AS MAPPED BY F.E.M.A. OR AS SCALE: As indicated "N y% '°/ ♦ END OF ROAD MARKERS 51.96'59'W C° f� ,: " X DEFINED BY ANY FEDERAL, STATE, OR LOCAL AUTHORITY IS LOCATED ON THIS I / N. SEE DETAIL 13/C701 51.96' PROPERTY (PER F.E.M.A. MAP N0 3720212000 J), DATED JUNE 2, 2006. EYP PROJECT NO.: 6013031.01 PROPOSED 40' ACCESS his t / / 3 PROPOSED TRANSFORMER ON AND UTILITY EASEMENT � �" 1 I Jv � ND DRIVEWAY STUB FOR CONCRETE PAD; REFER TO TURE CONNECTION TO ADJACENT PARCELL.D ELECTRICAL PLAN FOR PAD SPECIFICATIONS PROPOSED SIGNAGE TRAFFIC CONTROL SIGNS I w EASEMENT AREA TRACT B ; E.I. (CONTROL) AP CABINET 48 PAGE 33 BENCHMARK ELE , 40,46 MSL DESIGNED BY: AWK I a - BOCK 2698 PACE 808 R1-1 STOP 3o"x3o" DRAWN BY: 0 i CHECKED BY: RTF-LD CURVE RADIUS ARC �CHORD_ CHORD BEARING DELTA ANG � I I J am" C1 570.00 11132' 11 0141 N 13'24'51 " E 11'23'2 " I �'� C2 570.00 2 5.25' 291 A00' '5 ' " y 29*40'40 5 I C3 M S 4 ,5 E 2p S 1 '4 E 524 � ' ( �,.. 12" � STAKING AND ��R MATERIALS C201 LINE NCIDIS AN 1 � 1 S 2 `2 ' 5" 1 6' PLAN 0 15 30 60 i / AT EYP Architecture & DISTURBED AREA ASSOCIATED WITH ro -,° y Engineering, PC °" ,� °" "`• � CONSTRUCTION OF TEMPORARY L. � A GRAVEL ACCESS ROAD = 0.27 ACRES. �. ' ° 1 / F� 811 West Hargett Street ,c - M" / AREA TO BE TREATED BY SILT FENCE. i , // Q Raleigh, NC 27603 s \ Tel: 919 833 8818 „ wu �,�� Fax: 919 833 6898 PROPOSED t 800 LF OF SILT \ ' F F Al eypae.com \ � � FENCE ASSOCIATED WITH ' TEMPORARY GRAVEL ACCESS £ °-- 1 / \\ 01+ CONSULTANTS: PATH. SEE DETAIL 1/C702 Structural Engineering: %/1yhx \ SR 1502 Stewart Engineering, Inc. \ , / /! /i' 421 Fayetteville St., Suite 400 o o° / Raleigh, NC 27601 + _3 / t /+\ '' 0°0°0°o PROPOSED SILT FENCE, TYP. / / / Tel: 919 380 8750 0 0 0 0,j X 00�0�0�0�0SEE DETAIL 1 C702 // o �o 0 0 0 �o / / / Fax: 919 380 8752 y �' a��'�' \ a ,. �' VICINITY MAP N.T.S. x s Civil Engineering/ Landscape Architecture: �.. < TOPOGRAPHICAL AND BASE SURVEY INFORMATION OBTAINED FROM Cole Jenest &Stone, pa 71 HANOVER DESIGN SERVICES, P.A.. THIS INFORMATION WAS ORIGINALLY 119 East Hargett Street Suite 300 X / X / ylo, ISSUED AND SEALED BY GREG A. WAYNE; NORTH CAROLINA .__ PROFESSIONAL LAND SURVEYOR SEAL: L-2876, ON JULY 2, 2013. Raleigh, NC 27601 �. _-�X�--X �, PROPOSED IMPROVEMENTS FOR BRUNSWICK MEDICAL CENTER PARKWAY Tel: 919 645 5964 f SHOWN PER PLANS FOR "BRUNSWICK NOVANT MEDICAL CENTER ROADWAY Fax: 919 719 1819 J ,� / EXTENSION PROJECT," PREPARED BY SITE SOLUTIONS, P.A., DATED ' 0 ir 'Y ROCK CHECK DAM, TYP. FEBRUARY 21, 2014 Plumbing Mechanical Electical & Fire Protection: INSET 1 SCALE 1 " = 40' � ' �� ' '����� SEE DETAIL 13/C702 EYP, Inc 420-I-A The Parkway TRACT B MAP CABINET 48 PAGE 33 �/ LEGEND Greer, SC 29650 BOOK 268 PAGE, 808 1 „ � / SYMBOL DETAIL Tel: 864 334 0997 y �' DITCH A SEE DETAIL 9/C705 Fax: DENUDED LIMITS i////////�jj�i to �N CARO / / y ••.........,• Site Area Stabilization Stabilization Time �� P oR '' p a ::•oF E O,y'•.'L Description Time Frame Frame Exceptions Q Q Q� t� q �r�•� - STABILIZED CONSTRUCTION SEAL _ - / �� / / • Perimeter dikes, / -j : c-13610 0 4 C702 W CATCH BASIN INLET / / y O O ENTRANCE ` ?� c-�o3 PROTECTION TYP. > ' andslopesches 7 days bone �O O /CARC� ' •�- �,. d � i �� •� tiC I NEF' SEE DETAIL 8/C702 / ��' ,, / / Hi h uali ��� ��� '�. ••'' •••.. .. ••',Z•w��` / g Q ty �, tl T • .. • �, Water H W 7 days None ��`� s / FUN TON PARTNERS CAMERON � ( Q ) � X SILT FENCE 1/C702 ���ujilt %1%%%10 06 14 PROPERTIES, LTD ! Zones / / DB 2614 PG 989 I if slopes are 10' or PB 48 PG 34 I Slopes steeper 7 clays Tess in length and are 4 than 3:1 not steeper than 2:1, ''' / 14 days are allowed. ® INLET PROTECTION 7/C702 -LD C 7-days for slopes Slopes 3:1 or 14 days greater than 50 feet 201 /01 flatter in length w, T 9ii' O'\ ` All other areas None i ® ROCK CHECK DAM 13/C702 Fb �, i (except for y ° SF� %� '� ' �/ F�\ `� with slopes flatter 14 days g perimeters and e 9�p0 TRACT B than 4:1 FI W Zones' BRUNSW CK COUNTY HOSPITAL, LLC / / \ MAP CABINET 48 PANE 33 °-° *"Extensions of time may be approved by the permitting authority 1 REVIEW COMMENTS 06111114 TRAM, A BOOK 2698 PAGE 808 MAP CABINET 48 PACE 33 BOOK 2751 PACE 709 / I S �/ k based on weather or other site-specific conditions that make compliance CATCH BASIN INLET PROTECTION 8/C702 ' 2 BID DOCUMENTS 07/02/14 �� / + \ � � impracticable."(Section II.B(Z){b)) C-LD3 ADDENDUM 1 07125114 / \ SEE SHEET C304 FOR TEMPORARY 4 REVIEW COMMENTS 07131/14 u°, / / 5 NCDENR EROSION CONTROL 10106114 ` v ` � SEEDING SPECIFICATIONS 4 J�� \ 6 NCDENR STORMWATER 11114114 CONSTRUCTION SEQUENCE CONTRACTOR SHALL: �� / 1. OBTAIN GRADING PERMIT FROM THE NORTH CAROLINA DEPARTMENT OF ENVIRONMENT �� �� NATURAL RESOURCES. 2. SET, UP AN ON-SITE PRECONSTRUCTION CONFERENCE WITH INSPECTOR TO DISCUSS EROSION CONTROL MEASURES. FAILURE TO SCHEDULE SUCH CONFERENCE 48 HOURS # Revision Date 0 PRIOR TO COMMENCEMENT OF ANY LAND DISTURBING ACTIVITY IS A VIOLATION AND IS PROPOSED SILT FENCE, TYP. SUBJECT TO A FINE. SEE DETAIL 1 C702 3. INSTALL CONSTRUCTION ENTRANCE, SILT FENCE AND OTHER SEDIMENT CONTROL DEVICES AS SHOWN ON STAGE 1 PLAN. / 4. INSTALL SEDIMENT BASIN WITH DITCH A TO NORTH END OF SITE. SCO I D#: 07-07054-02J 5. CALL FOR AN ON-SITE INSPECTION. WHEN APPROVED, BEGIN ONSITE DEMOLITION, AND CLEARING. .� �`°, 6. COMPLETE SUBGRADE EXCAVATION AND SOIL REPLACEMENT PER STAGE 2 PLAN. 7. INSTALL INLET PROTECTION AT ALL PROPOSED DRAINAGE INLETS AS THEY ARE INSTALLED AND DIRECT RUNOFF TO DITCH AND BASIN. , ,,,'`````` � � `` �� � `•,, ��:, ',,°° 8. STABILIZE SITE AS AREAS ARE BROUGHT TO FINISHED GRADE. 9 ONCE APPROPRIATE HAVE BEEN PROTECTION INSTALLED,. COORDINATE LETS MAY BE OPENED WITH ATE \ I � / WITH EROSION <,,,, '. i' f O _..,. \ CONTROL T N ECTOR. h. A ti e1, 10. CALL FOR ONSITE INSPECTION ONCE ALL AREAS HAVE BEEN STABILIZED. `\ , // �� � ,�"'° 11. CONVERT SEDIMENT BASIN TO PERMANENT STORMWATER BASIN , ..„„ i / i 9° � _ _, q � __ �� �.,,,, 1 RE N L DEVICES UPON APPROVAL OF THE 12 STABILIZE ALL DISTURBED AREAS AT BASIN. 3 DISTURBED AREAS. '"" MOVE ALL REMAINING EROSION CONTROL EROSION CONTROL INSPECTOR AND STABILIZE Community Service EROSION CONTROL NOTES Hv L t #8 NC TYP. STRICT ACCORDANCE WITH LOCAL Learning rn i g Center n e r PROPOSED 20 X 50 ■ CONSTRUCTION ENTRANCE, n 1. ALL EROSION CONTROL MEASURES SHALL BE IN ! SEE DETAIL 4/C702 AND/OR STATE STANDARDS. Brunswick 2. THE CONTRACTOR SHALL DILIGENTLY AND CONTINUOUSLY MAINTAIN ALL EROSION ♦ a��'nR CONTROL DEVICES AND STRUCTURES TO MINIMIZE SEDIMENTATION. THE CONTRACTOR N 1 041 8 71,03 SHALL MAINTAIN CLOSE CONTACT WITH INSPECTOR SO THAT PERIODIC INSPECTIONS ♦ E:2225054°47 CAN BE CONDUCTED AT APPROPRIATE STAGES OF CONSTRUCTION. East Carolina University N.A.D. 1983 3. THE TOTAL DISTURBED AREA IS 4.32 ACRES. School of Dental Medicine \ \ E,L (CONTROL.) ♦�/' 4. THE TOTAL SITE ACREAGE IS 2.32 ACRES. .(pR TELEGRAPH COMPANY Brunswick Count NC 5. THE SOIL CLASSIFICATION IS Wo OODINGTON FINE SANDY LOAM). AMERICAN TELEPHONE AND (W M). y \ J� ♦ ♦ 20'EASEMENT D.B. 719 PG. 1049 6. FINAL LOCATION OF SILT FENCE, DIVERSION DITCHES, ETC. SHALL BE ADJUSTED IN THE FIELD BY CONTRACTOR BASED ON SITE CONDITIONS AND INSPECTOR'S r0 / o ,c• i T ♦ � p2B RECOMMENDATIONS. � o �O'.fl FAQ `S'>,Q �` ``,--� �,,�� ♦ ,Z* W lj/ 1Cy O O O O-° �� 7. ADDITIONAL EROSION CONTROL DEVICES MAY BE REQUIRED DUE TO FIELD CONDITIONS 0 0 Q OR AS DIRECTED BY THE INSPECTOR. " �- � ♦ DATE: 07/0212014 0000 8. THE SITE SHALL BE GRADED DURING CONSTRUCTION TO ALLOW ALL STORM WATER TO 00 „ .-� ♦ DRAIN TO EROSION CONTROL DEVICES. SCALE: AS indicated 0 0 0 0 \ !" EYP PROJECT NO.: 6013031.01 9. STABILIZATION IS THE BEST FORM OF EROSION CONTROL. TEMPORARY SEEDING IS CATCH BASIN INLET ,� j / / !` 0000, j` ® SON MUST C NECESSARY TO ACHIEVE EROSION CONTROL ON LARGE DENUDED AREAS AND PROTECTION, TYP. ; d O: / DISTURBED AREA TO BASIN 1 = 4.05 ACRES G� 1LITY 0411 ESPECIALLY WHEN SPECIFICALLY REQUIRED AS PART OF THE CONSTRUCTION SEQUENCE .1 � O 0 t7" o '°R O INDICATED ON THE CONSTRUCTION SEE DETAIL 8/C702 � � {� 1f I, � � O O O O ���p Off. ON DOCUMENTS. ALL GRADED SLOPES SHALL BE SEEDED O TOTAL DISTURBED AREA = 4.32 ACRES ?�J o F�� AND MULCHED WITHIN 15 DAYS OF COMPLETION OF GRADING. UNSCK COUNTS _ i fzn' �.< �. ,/ 1ka -- E.C.M. �� 0 0 # I l �� -- "?6 ` DISTURBED AREA NOT BEING TREATED BY J w z i 10. ALL EROSION CONTROL DEVICES SHALL BE INSPECTED FOLLOWING EACH RAIN EVENT AI, LLC MAP CABINET ` Q o m AND NECESSARY REPAIRS MADE WITHIN 24 HOURS. E 33 TRACT A BOOK ; C i ' ,<' I l' I " BASIN 1 (AREA ASSOCIATED WITH TEMPORARY z D DESIGNED BY: AWK �� 2751 PAGE 700 i � 1 ; 1 � `� GRAVEL ACCESS PATH TO SITE) = 0.27 - (` ACRES DRAWN BY: t I i' �`"` ac 1 TEMPORARY GRAVEL ACCESS' REFER TO C403 FOR TOTAL DRAINAGE AREA BBPORBYOUDIGI CHECKED BY: RTF me-LDJ' �''' �/ 0 ♦ � PATH TO SITE REFER TO INSET � �� ` I �- � � / �-�" ♦ �� � � � �,. TO BASIN 1 CONTACT ONBrCAIL C�Tl'Et d" ,' 1 ON C301 FOR ADDITIONAL 1-800-632-4949 PROPOSED 40' ACCESS I i / �♦ B° INFORMATION. AND UTILITY EASEMENT 1. CONTRACTOR IS FULLY RESPONSIBLE FOR CONTACTING APPROPRIATE PARTIES AND ASSURING THAT EXISTING UTILITIES ARE LOCATED PRIOR TO CONSTRUCTION. 2 2. CONTRACTOR IS RESPONSIBLE FOR PLACING BARRICADES USING FLAG MEN, ETC. AS PROPOSED SIGNAGE i ° ` I TRACT 8 NECESSARY TO INSURE SAFETY TO THE PUBLIC. EROSION EASEMENT AREA i " '� E.I.I CO O % `',r# ` MAP CABINET 48 PAGE 33 3. ALL PAVEMENT CUTS, CONCRETE OR ASPHALT, ARE TO BE REPLACED ACCORDING TO r� i ( � � E Vr-p i � -; a BENCHMARK ELEV. 40.46 MSL. ' " BOOK 2698 PAGE 8J8 CONTROL I 1 . _, ,% STANDARDS OF THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION. N 1 ' I = i < 4. SHORING WILL BE ACCORDING TO OSHA TRENCHING STANDARDS PART 1926 SUBPART SCALE: 1" 30' STAGE 1 C301 V,cII .., g` I)' %� , P, OR AS AMENDED. 11 C-LD0 15 30 60 PLAN :;� �� + EYP Architecture & PERMANENT OUTLET CONTROL ;' = - - Engineering, PC STRUCTURE AND PIPE SEE GRADING AND DRAINAGE �� YP / �� ,�� �� �� _ 811 West Hargett Street PLAN f y: =— "� FEs-2 Q �� Raleigh, NC 27603 '� �S Tel: 919 833 8818 r ocs-1 Fax: 919 833 6898 eypae.com �. CONSULTANTS: JAX Structural Engineering: SR 1502 Stewart Engineering, Inc. / \ 421 Fayetteville St., Suite 400 �h f � Raleigh, NC 27601 kn \\ Tel: 919 380 8750 / N Fax: 919 380 8752 ' � �. VICINITY MAP N.T.S. �� Civil Engineering/ Landscape Architecture: p A TOPOGRAPHICAL AND BASE SURVEY INFORMATION OBTAINED FROM Cole Jenest &Stone, a P p " ` HANOVER DESIGN SERVICES, P.A.. THIS INFORMATION WAS ORIGINALLY 119 East Hargett Street, Suite 300 ISSUED AND SEALED BY GREG A. WAYNE; NORTH CAROLINA i PROFESSIONAL LAND SURVEYOR SEAL: L-2876, ON JULY 2, 2013. Raleigh, NC 27601 V -" PROPOSED IMPROVEMENTS FOR BRUNSWICK MEDICAL CENTER PARKWAY Tel: 919 645 5964 .' DATED aX. SHOWN PER PLANS FOR BRUNSWICK NOVANT MEDICAL CENTER ROADWAYF 919 719 1819 � EXTENSION PROJECT, PREPARED BY SITE SOLUTIONS, P.A., y � FEBRUARY 21, 2014 Plumbing Mechanical Electical & Fire Protection. \ EYP, Inc \ 420 I A The Parkway LEGEND Greer, SC 29650 SYMBOL DETAIL Tel: 864 334 0997 v Fax: DENUDED LIMITS � ► i h SKIMMER ���/// ii�' �. �� CARO� _� �I 0�k � Y��� O O STABILIZED CONSTRUCTION 4 C702 W : SEAL 4... # / O O ENTRANCE / p do c 1031 Q .1: �� DOUBLE ROW SILT FENCE CW �� •,, ��LC I NEF.Q`: A •• •• AT BASIN PERIMETER TYP. ., ����� '���� ,,�� .... •• '•5���� /r I f' a � /r X SILT FENCE 1 C702 ��////////�� i,,���D F `` 10/06/14 �0 a TEMPORARY SEDIMENT BASIN 1 sue,� � .Y'lA,.� , � b. .,, ._,. SEE DETAIL 1/C706 \ N. �.... 1 .. . ®�. INLET PROTECTION 7/C702 ( F BAFFLES �. . i SEE DETAIL 7/C705 — _ \ All - ROCK CHECK DAM 13/C702 \� �. + '$ 1 REVIEW COMMENTS 06111114 + m \ CATCH BASIN INLET PROTECTION 8/C702 ® 2 BID DOCUMENTS 07102114 4— 411 �� PROPOSED SILT FENCE, TYP. I - .. .. 3 ADDENDUM 1 07/25/14 SEE DETAIL 1/C702 I � - - 4 REVIEW COMMENTS 07131114 _ .. _ �- / 5 NCDENR EROSION CONTROL 10106114 P- + + ,t 4- 4- t % ROCK CHECK DAM, TYP. / SEE DETAIL 13/C702 6 NCDENR STORMWATER 11114114 - - .. / a _.. _ " g � _t_ ..a€_ ti C304 FOR TEMPORARY ,r SEE SHEET „- ;_ -I- EEDING SPECIFICATIONS r.., ... + _ ..r ��� . ._- # Revision / SEE SHEET C301 FOR EROSION Date 4, 4 - / �� CONTROL NOTES AND CONSTRUCTION SEQUENCE SCO I D#: 07-07054-02J : q / � a / Community Service a r ' Learning n / g Center #8 t ��/ Brunswick �. ° East Carolina University School of Dental Medicine - Brunswick County NC .. DITCH A SEE DETAIL 9/C705 =4p, x ` DATE: 07/02/2014 411 1, / SCALE: As indicated s EYP PROJECT NO.: 6013031.01 f- f MUST T Co/ V �JG��(1LITY p �Y,�o R \+ 4 Q z DESIGNED BY: AWK DRAWN BY. `-f 5 € �i BI1IaORB YOU DIG! CHECKED BY: RTF / CONTACT ONE-CALL(ENTER 1-800-632-4949 1. CONTRACTOR IS FULLY RESPONSIBLE FOR CONTACTING APPROPRIATE PARTIES AND / %,9 ASSURING THAT EXISTING UTILITIES ARE LOCATED PRIOR TO CONSTRUCTION./3 /X I "I I " _ � 1 ' �j 2. CONTRACTOR IS RESPONSIBLE FOR PLACING BARRICADES USING FLAG MEN, ETC. AS �+ .,°' / F'L NECESSARY TO INSURE SAFETY TO THE PUBLIC. EROSION � 3. ALL PAVEMENT CUTS, CONCRETE OR ASPHALT, ARE TO BE REPLACED ACCORDING TO CONTROL STANDARDS OF THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION. N C30 I . 2 4. SHORING WILL BE ACCORDING TO OSHA TRENCHING STANDARDS PART 1926 SUBPART SCALE: 1 = 30' STAGE 1 { f / P, OR AS AMENDED. PLAN :- , 0 15 30 60 + F EYP Architecture A & h•t t ec ure / t f". ��` .. + Engineering, PC / g I. I / 811 West Hargett Street YP / + / - '� , �/ Q Raleigh, NC 27603 4,, Tel: 919 833 8818 ... ..7.. > '.. Fax: 919 833 6898 eypae.com �i SIT J� CONSULTANTS: mr. + 4, ; ,. J �/ Structural Engineering: 1502 � � � ;��� �` sR 421 Fayetteville Stewart St.nSulte 400 ���$� �i d € / / � / �, Raleigh, NC 27601 PROPOSED SILT FENCE, TYP. - / Tel: 919 380 8750 SEE DETAIL 1/C702 �/ � .,,�� � / Fax: 919 380 8752 / // / VICINITY MAP N.T.S. .� Civil Engineering/ Landscape Architecture: try / TOPOGRAPHICAL AND BASE SURVEY INFORMATION OBTAINED FROM Cole Jenest & Stone, pa ° / t HANOVER DESIGN SERVICES, P.A.. THIS INFORMATION WAS ORIGINALLY 119 East Hargett Street, Suite 300 ISSUED AND SEALED BY GREG A. WAYNE; NORTH CAROLINA PROFESSIONAL LAND SURVEYOR SEAL: L-2876, ON JULY 2, 2013. Raleigh, NC 27601 \♦ PROPOSED IMPROVEMENTS FOR BRUNSWICK MEDICAL CENTER PARKWAY Tel: 919 645 5964 /2 // SHOWN PER PLANS FOR "BRUNSWICK NOVANT MEDICAL CENTER ROADWAY Fax: 919 719 1819 / EXTENSION PROJECT," PREPARED BY SITE SOLUTIONS, P.A., DATED ROCK CHECK DAM TYP. FEBRUARY 21, 2014 Plumbing Mechanical Electical & Fire Protection: SEE DETAIL 13/C702 EYP, Inc / 420-1-A The Parkway TRACT 8 LEGEND Greer, SC 29650 , � � �'� / MAP CABINET 48 PAGE 33 / „� / Tel: a 864 334 0997 BOOK 269 PAGE 808 / M�. / DITCH A SYM OL DETAIL SEE DETAIL 9/C705 Fax. 1.D %till ►�i DENUDED LIMITS -/- } 11111/&�����_ ��`•``,`` CAR ,�''•,�� `��� �S ST'�_ pR� g S i � '� �a / 0 ' SEAL �^': _ ��-� / s � ���� O O 4/c702 � w : � O O STABILIZED CONSTRUCTION ` ENTRANCE p :- , C-1o3 2Q CATCH BASIN INLET L) pry F PROTECTION, TYP. / =— CAR �N ',� 'yC I NEF' SEE DETAIL 8/C702 y �� �,� �'• •..... •. S.Z.``�. FONBTON PARPNIERS & CAMERON X SILT FENCE 1/C702 ' I�� �� llll%1%%%%10 PROPERTIES, ,LTD1 / 4 DB 2614 PO 989 v PB 48 PC 34 1 � I H� ® INLET PROTECTION 7/C702 TJ 9i� / ® ROCK CHECK DAM 13/C702 • tip' / pp TRACT B \ BRUNSWCK COUNTY HOSPITAL, LLC ` ` �. " � - / ` �' MAP CABINET PAGE 33 e 1 REVIEW COMMENTS 06111114 'TRACT A / / I / ` BOOK 2698 PAGE 808 � MAP CABINET PAGE 33 BOOK 2751 PAGE 709 f,S. � z / \ CATCH BASIN INLET PROTECTION 8/C702 2 BID DOCUMENTS 07102114 DISCHARGE \ Q3 3 ADDENDUM 1 07125114 „ y THROUGH DIRTBAG L C. 0 /dl/ FILTER TO DITCH i<8. \ �� "" 4 REVIEW COMMENTS 07131114 TEMPORARY PIEZOMETER \ (REFER TO SPECIFICATIONS) lk� - ' ' // 5 NCDENR EROSION CONTROL 10106114 6 NCDENR STORMWA TER 11114114 vv * SEE SHEET C301 FOR EROSION / 50• \ CONTROL NOTES AND CONSTRUCTION SEQUENCE OF DEWATERING PUMP <v EROSION CONTROL DEWATERING, N-S # Revision Date FILTER SUMP; FLOW TO DISCHARGE THROUGH \ ' SEE DETAIL 11/C702 DIRT BAG FILTER TO DITCH; PROPOSED SILT FENCE, TYP. CONSTRUCTION SEQUENCE FOR SEE DETAIL 11/C702 SEE DETAIL 1/C702 SCO I D#: 07-07054-02J UNDERCUTTING AND FILL REPLACEMENT �°• AT BUILDING PAD AND PAVEMENT AREAS OF . 1. CONTRACTOR SHALL EXCAVATE BUILDING PAD AREA TO A MINIMUM OF 4' BELOW Q 36.50. \ EXISTING GRADE ELEVATION AND PAVEMENT AREAS TO A MINIMUM 2' BELOW ``� � /V` °� I <v� // \ EXISTING GRADE AS INDICATED ON DRAWING. LIMITS OF BUILDING PAD EXCAVATION "` SHALL EXTEND A MINIMUM OF 10' BEYOND BUILDING LINES ON ALL SIDES. LIMITS / � OF PAVEMENT AREA EXCAVATION SHALL EXTEND A MINIMUM OF 2' BEYOND _7 d �; ;'Y r O / ' PROPOSED BACK OF CURB IN ALL AREAS. el MAW lar 2. DETERMINED TO BE TOO WET OR OTHERWISE ALL EXCAVATED MATERIAL THAT IS �W UNSUITABLE FOR BACKFILL,TASTDETERMINED BY THE GEOTECHNICAL ENGINEER, SHALL BE HAULED FROM THE SITE AND DISPOSED PER LOCAL ORDINANCES. ■ Commune Service " \ f, " ' / I / FUTURE �! 3. CONTRACTOR SHALL PROVIDE ALL DEWATERING MEASURES NECESSARY, INCLUDING Community r I WELLPOINTS, SUMP PUMPS, TEMPORARY SHORING, ETC., TO ENSURE COMPLETION E I XPANSION PROPOSED 50 ,,, """ � OF STABLE EXCAVATION AND BACKFILL OPERATIONS. GROUNDWATER SHALL BE ■ / OUTLINE CONSTRUCTIENTR CE �/ ,�-� � � Learning Center #8 tf BUILDING MAINTAINED A MINIMUM OF 2' BELOW THE BOTTOM OF ALL EXCAVATIONS.OUTLINE SEE DETAIL 4/C70 ■ MECHANICAL N/ 4. BEFORE INITIATING EXCAVATION, INSTALL TEMPORARY STANDPIPE PIEZOMETERS AT Brunswick YARD OUTLINE LOCATIONS INDICATED TO DEPTHS OF 5' BELOW TEMPORARY EXCAVATION GRADES. N104187 03 PIEZOMETERS SHALL CONSIST OF 1" TO 2" DIAMETER SLOTTED PVC, INSTALLED IN f Ee222505447 3" MINIMUM DIAMETER BOREHOLE, AND BACKFILLED WITH MANUFACTURED WELL East Carolina University \W r �° \ / ♦ N,A63, 198.E SCREEN, MEDIUM TO COARSE SAND. .'° \ ��ro� `� � 1 � � "� •� � � a � �„•�....�-�"' �. � School of Dental Medicine \ \ E.L (CONTROL)J 5. THE GEOTECHNICAL ENGINEER SHALL MEASURE GROUNDWATER LEVELS IN THE h f / \ \ r Rp/.- PIEZOMETERS APPROXIMATELY 24 HOURS AFTER INSTALLATION AND DAILY THERE �# , I II REPR%� ' TELEGRAPH COMPANY AFTER. Brunswick County NC AMERICAN TELEPHONE AND 6. ONCE COMPLETED, EXCAVATIONS HAVE BEEN APPROVED BY THE GEOTECHNICAL ♦/� ♦ 20'EASEMENT D.B. 719 PG. 1049 ENGINEER, INSTALL A WOVEN GEOTEXTILE (MIRAFI 50OX OR APPROVED EQUIVALENT) / AT THE BOTTOM OF ALL EXCAVATED AREAS. I _". - oo O'O.," Q T / � ♦ 7. BACKFILL EXCAVATIONS WITH IMPORTED SUITABLE FILL MATERIAL APPROVED BY THE j OOOb ,Ty � � / a°�• 0 GEOTECHNICAL ENGINEER AND HAVING A UNIFIED SOIL CLASSIFICATION OF SW, SP, O 0 O O" _ T 'r tom / 3 SW-SM, SW-SC, SP-SM, OR SP-SC, FREE OF ORGANICS AND DELETERIOUS DATE: r / ♦ 0710212014 r �" O O \ ~"` ♦ MATERIAL. BACKFILL SHALL BE PLACED IN MAXIMUM 10" LIFTS AND COMPACTED. w REFER TO SPECIFICATIONS. SCALE: As indicated EYP PROJECT NO.: O O O O ♦ 8. FIVE FEET OF SOLID PVC SHALL BE ADDED TO THE TOP OF THE PIEZOMETERS AND 6013031.01 r l y 0000 " THE PIEZOMETERS SHALL REMAIN IN PLACE AS BACKFILL IS PLACE. CARE SHALL CATCH BASIN INLET -. _ r1 /� � SON MUST O BE TAKEN TO ENSURE THAT THE PIEZOMETERS ARE NOT DAMAGED OR DESTROYED. PROTECTION, TYP. I f °" ' l O O O O. 00 /n``" DISTURBED AREA TO BASIN 1 = 4.05 ACRES �G� �XL I I p QN,� SEE DETAIL 8/C702 I f _ / k ` "" y/ ���p 'QOT�'Py 9. CONTINUE SUITABLE SOIL FILL TO FINAL SUBGRADE ELEVATIONS PER THE GRADING WI *NN / TOTAL DISTURBED AREA = 4.32 ACRES v C��o AND DRAINAGE PLAN. UNCK COUNTY it y3 `f ... / o o O i { / w y h E.C,P�1, AL, LLC MAP CABINS. r I I ►= I ,1 „� ':t t F` DISTURBED AREA NOT BEING TREATED BY ; 10. PROOFROLL FINISHED SUBGRADE WITH A LOADED TANDEM-AXLE DUMP TRUCK OR E 33 TRACT A BOOK I % I 3 Ir` ( ` r f BASIN 1 (AREA ASSOCIATED WITH TEMPORARY Q Z n ''� APPROVED RUBER-TIRED EQUIPMENT IN THE PRESENCE OF THE GEOTECHNICAL DESIGNED BY: AWK 2751 PACE 709 GRAVEL ACCESS PATH TO SITE) = 0.27 ENGINEER OR HIS REPRESENTATIVE. ACRES DRAWN BY: t D11 s I;' I a, � �/ "-•� r 1 11. REMOVE STANDPIPE PIEZOMETERS AND BACKFILL HOLES WITH BENTONITE CHIPS OR CHECKED BY: RTF 1 �, ,,♦ TEMPORARY GRAVEL ACCESS REFER TO C403 FOR TOTAL DRAINAGE AREA BBFORSYOUDIGI PELLETS. ' ' �� ♦ PATH TO SITE REFER TO INSET TO BASIN 1 CONTACTONB CAIs.CffiVTBR wor— �� r r 1 '"' �� � 1 ON C301 FOR ADDITIONAL 1-800-632-4949 12. CONTRACTOR SHALL INCLUDE IN THE BASE BID PRICE ALL EXPORT AND DISPOSAL PROPOSED 40' ACCESS „ � Ea INFORMATION. OF EXCAVATED UNSUITABLE MATERIAL AND ALL IMPORT AND PLACEMENT OF AND UTILITY EASEMENT f r / , "y` 1 1. CONTRACTOR IS FULLY RESPONSIBLE FOR CONTACTING APPROPRIATE PARTIES AND *** SUITABLE BACKFILL AND FILL MATERIAL RE UIRED TO ACHIEVE FINAL GRADES AS r ASSURING THAT EXISTIN UTILITIES ARE LOCATED PRIOR TO CONSTRUCTION. Q 1x DESCRIBED ON THE DRAWINGS AND SPECIFICATIONS. ONLY SUCH ADDITIONAL i EXCAVATION AND SUBGRADE REPLACEMENT BEYOND THE LIMITS SHOWN, AS MAY i 2. CONTRACTOR IS RESPONSIBLE FOR PLACING BARRICADES USING FLAG MEN, ETC. AS " ""� BE APPROVED BY THE GEOTECHNICAL ENGINEER, SHALL BE PAID UNDER THE EROSION PROPOSED SIGNAGE "�� "��, � FACT 8 `��, NECESSARY TO INSURE SAFETY TO THE PUBLIC. PROJECT ALLOWANCES FOR UNSUITAB%LE SOIL. EASEMENT AREA r" "� ro"- _____ ' E.I. (CONTROL) 1 MAP CABINET 48 PAGE 33 3. ALL PAVEMENT CUTS, CONCRETE OR ASPHALT, ARE TO BE REPLACED ACCORDING TO CONTROL BENCHMARK ELEV. 40.46 MSL 1 y 4 BOOK 2698 PAGE 808 STANDARDS OF THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION. N C303 g I % SCALE: 1" = 30' STAGE 2 r ( A 4. SHORING WILL BE ACCORDING TO OSHA TRENCHING STANDARDS PART 1926 SUBPART r i # ' i i ., 1 P, OR AS AMENDED. r , PLAN ' r f '° 0 15 30 60 / + + ,f EYP Architecture Engineering, PC + I // 811 West Hargett Street YP / / Q 1 I Raleigh, NC 27603 =r„ + '�, '9/ 135 Tel: 919 833 8818 1 / - / I / �"a / Fytiy Fax: 919 833 6898 VI.. .. .. .. wI_ + + + Yp / e ae.com IS0 ;, " / / � , �/ SIT J� 1 CONSULTANTS. Structural Engineering: + + 4/ + % r + _ // SR 1502 1 �` / Stewart Engineering, Inc. 4'r / 421 Fayetteville St., Suite 400 + ._ RalTeleigh, NC NC 27601 6 01 PROPOSED SILT FENCE, TYP. / 'I f ... \ SEE DETAIL 1/C702 �// / N Fax: 919 380 8752 y // VICINITY MAP N.T.S. 71 a Civil Engineering/ Landscape Architecture: ° ;I %� / "' � // TOPOGRAPHICAL AND BASE SURVEY INFORMATION OBTAINED FROM Cole JeneSt & Stone, pa y HANOVER DESIGN SERVICES, P.A.. THIS INFORMATION WAS ORIGINALLY 11 E Hargett r ISSUED AND SEALED BY GREG A. WAYNE; NORTH CAROLINA 9 East a gett Street, Suite 300 PROFESSIONAL LAND SURVEYOR SEAL: L-2876, ON JULY 2, 2013, Raleigh, NC 27601 PROPOSED IMPROVEMENTS FOR BRUNSWICK MEDICAL CENTER PARKWAY Tel: 919 645 5964 SHOWN PER PLANS FOR "BRUNSWICK NOVANT MEDICAL CENTER ROADWAY Fax: 919 719 1819 / EXTENSION PROJECT," PREPARED BY SITE SOLUTIONS, P.A., DATED ROCK CHECK DAM, TYP. FEBRUARY 21, 2014 SEE DETAIL 13/C702 Plumbing Mechanical Electical & Fire Protection: EYP, Inc 420 I A The Parkway TRACT B ' LEGEND Greer, SC 29650 MAP CABINET PAGE 33 �" „�� r ` ' / BOOK 2698 PAGE 808 Tel 864 334 0997 DITCH A SYMBOL DETAIL SEE DETAIL 9/C705 Fax: C-LD DENUDED LIMITS -/- ���u�iin►��� PROPOSED 20' X 50• / /// ''til// I�j���i ��� N CAR CONSTRUCTION ENTRANCE, TYP. �1 ST & S ��� �t :••• SEE DETAIL 4/C702 / ' // /// ,�����F. ... ...., TO- �O .• F ESS/O C.7i / O O ENTRANCED CONSTRUCTION ; J : SEAL % ; CV 4/C702 c-1361 \ CATCH BASIN INLET / `/ / p zo c-103 zF: 5 PROTECTION, TYP. �"� % v �'�x,cAR0- �� F SEE DETAIL 8/C702 / r ,"', �/ / �� ....... ` ;�� '•.�G I t4 • �`��: . eNS'i � PARTNERS "AMERO€ D D.•F•����� t i. w ro PROPERTIES, LTD �nnnu%� / / X SILT FENCE 1/C702 ���i ���` *q, h 10 06 14 /, � �, //..;• DB 2614 PO 989 4, PB 48 PG 34 " � "` ` � 1 ♦ ° C ® INLET PROTECTION 7/C702 -LD 00. U/01 3 Qa r 00 �F`9�9�, / S� ♦ ® ROCK CHECK DAM 13/C702 BRUNSWICK COUNTY HOSPITAL, LLC cs, �\. ` �� �� TRACT 5 MAP CABINET 48 PAGE 33 � TRACT A / w BOOK, 2698 PAGE' 808 1 REVIEW COMMENTS 06/11/14 MAP CABINET PACE 33 BOOK 2751. PAGE 709 � � � � � LB. X � � ♦ ��. � CATCH BASIN INLET PROTECTION 8/C702 2 BID DOCUMENTS 07102114 C L _a`. ��" ' o O oC D 3 ADDENDUM 1 07125114 11. V` ° O o 4 REVIEW COMMENTS 07131114 „4y � Q O° O INLET PROTECTION, TYP. 5 NCDENR EROSION CONTROL 10/06/14 4 / OO O SEE DETAIL 7/C702 Q P 6 NCDENR STORMWATER 11114114 J \ / 4 '�`� SEE SHEET C301 FOR EROSION CONTROL NOTES AND CONSTRUCTION`f 1 SEQUENCE # Revision Date PROPOSED SILT FENCE, TYP. � / { SEE DETAIL 1/C702 SCO I D .# 07 07054 02J O, TEMPORARY SEEDING SPECIFICATIONS (Ppiv � ' �� ��\ \ 3:1 SLOPES OR FLATTER � / / \ ♦ 1. APPLY AGRICULTURAL LIME AT THE RATE OF 90 LBS/1000 S.F. w,�•,.-- '~ " / i '" '%" \ \ 2. APPLY 10-10-10 COMMERCIAL FERTILIZER AT x THE RATE OF 20 LB ._._, S/1000 S.F. - 3. SEED IN ACCORDANCE W w k. TH THE FOLLOWING SCHEDULE A A S. , �. � � � �- � � S E AND APPLICATION RATE Q i f7 �� • ®` DATE: TYPE: PLANTING RATE AUG. 15 - NOV. 1 TALL FESCUE 300 LBS/AC OR 7 LBS/1000 S.F. NOV. - Community Service 0 1 MAR. 1 TALL FESCUE AND 300 LBS/AC OR 7 LBS/1000 S.F. ROPOSED 20 O ABRUZZI RYE 25 LBS AC OR 1/2 LB 1000 S.F. e�lO �� ��CONS ON<`ENTRAN }� �` MAR. 1 - APR. 15 TALL FESCUE 300 LBS/AC OR 7 LBS/1000 S.F. Learning Center #8 DETAIL 4/C70 .- APR. 15 - JUL. 30 MULLED COMMON "zz�v l� �p0\�� / , r BERMUDA GRASS 30 LBS/AC OR 1/2 LB/1000 S.F. JUL. 15 - AUG. 15 TALL FESCUE AND 300 LBS/AC OR 7 LBS/1000 S.F. Brunswick a \ C1J 4Q 35 LB \ ¢ `/r / ~... . s o / HUM SUDAN C OR L 000 S.F. BROWN TOP MILLET S/A 3/4 B/1 X •-/ / ' f� �� N.A.D. 1983 HYBRIDS 30 LB C OR L 1000 S.F. EastCarolina '� E222054 4`� S/A 3/4 B/ Ea University 4. MULCH WITH STRAW APPLIED AT THE RATE OF 75-1000 LBS/1000 S.F. School of Dental Medicine E,L (CONTROL) \ � ` „ * HEAVILY MULCHED DURING JANUARY - MARCH PERIOD. \ \.�.. L F� y / `' �� REPRO' TELEGRAPHCOMPANY / . 2. \ / / I !i / ?, �S �' - / jJ� AMERICAN TELEPHONE AND THAN 3:1 Brunswick County NC �� / SLOPES GREATER T I S , .- 1. APPLY AGRICULTURAL LIME AT A RATE OF 90 LBS/1000 S.F. 20'EASEM NT D.B. 719 PG. 1049 j � �'. , o O"""fl � � �w ems- � /�,•-- � �0`�• 2 APPLY 10 10 10 COMMERCIAL FERTILIZER AT THE RATE OF 20 LBS/1000 S.F. iI 00 \ �F �/ °52 3. SEED IN ACCORDANCE WITH THE FOLLOWING SCHEDULE AND APPLICATION RATES: O ' � � ♦ DATE: TYPE: PLANTING RATE: DATE: 07/02/2014 g i 00 �;: �. ��-�' / MAR. - JUN. 1 SERICEA LESPEDEZA 50 LBS/AC OR 1 1/2 LBS/1000 S.F. SCALE: AS Indicated �� �� ifs` 4 O ��/ 000 (SCARIFIED) AND EYP PROJECT NO.: 6013031.01 MAR. - APR. 1 ADD TALL FESCUE 150 LBS/AC OR 3 1/2 LBS/1000 S.F. CATCH BASIN INLET " 0000 O O O O / O O O O ��� TYP. i I`ua 1 r 1 / , G PROTECTION, j 0000 �pN MUST SEE DETAIL 8�C702 DISTURBED AREA TO BASIN 1 = 4.05 ACRES �G� \�L I TY JUN. - SEPT. 1*** TALL FESCUE AND 60 LBS/AC OR 1 1/2 LBS/1000 S.F. i �` A fl O O O ���Q 'Qp�O BROWN TOP MILLET 35 LBS/AC OR 3/4 LB/1000 S.F. O / �"' TOTAL DISTURBED AREA = 4.32 ACRES O� J� o F OR SORGHUM SUDAN N CK COUNTY i „' / X'%' G` E.C,M. v �� O HYBRIDS 30 LBS AC OR 3 4 LB 1 / / / 000 S.F. AL, LLC MAP CABINET e� s m- .� '' DISTURBED AREA NOT BEING TREATED BY J w z = SEPT. - MAR. 1 SERICEA LESPEDEZA 70 LBS/AC OR 1 3/4 LBS/1000 S.F. IN 33 TRACT A BOOK f , �; - '">"~ -_ '`11 BASIN 1 (AREA ASSOCIATED WITH TEMPORARY Q � m (UNHULLED - UNSC4RIFIED) 275 PAG:r 709 I � `#; �"� _"- `'\ GRAVEL ACCESS PATH TO SITE) = 0.27 TALL FESCUE 150 LBS/AC OR 3 1/2 LBS 100o S.F. DESIGNED BY: AWK ACRES MILLET OR SUDAN 20 LBS/AC OR 1/2 LB/1000 S.F. DRAWN BY: ( I ;l � F ,/ � TEMPORARY GRAVEL ACCESS REFER TO C403 FOR TOTAL DRAINAGE AREA BEFORE YOU DIGI 4. MULCH WITH 6" STRAW APPLIED AT THE RATE OF 60-70 LBS/1000 S.F. AND ANCHOR CHECKED BY: RTF W-LDa 1 / o PATH TO SITE, REFER TO INSET TO BASIN 1 � �' � -a � NI'ACI'0N8-CAL.LCSNTffit WITH ASPHALT EMULSION TACK COAT APPLIED AT THE RATE OF 14-28 GAL/1000 S.F. 1 ON C301 FOR ADDITIONAL ' ��"' 1-800-632-4949 OR 800-1200 GAL AC. PROPOSED 40' ACCESS i I I j r� t8°3 1 INFORMATION. AND UTILITY EASEMENT 1. CONTRACTOR IS FULLY R 'SPONSIBLE FOR CONTACTING APPROPRIATE PARTIES AND *** ASSURING THAT EXISTING UTILITIES ARE LOCATED PRIOR TO CONSTRUCTION. TEMPORARY. RESEED SEPT. 1 AT RECOMMENDED RATES. '"� % 2. CONTRACTOR IS RESPONS BLE FOR PLACING BARRICADES USING FLAG MEN, ETC. AS PROPOSED SIGNAGE ­311 NECESSARY TO INSURE SAFETY TO THE PUBLIC. EROSION EASEMENT AREA i ' �; ) 1, ` 1 "' TRACT 8 " I BEE.I HMARK(CONTROL) 1% 7 „ MAP CABINET 48 PAGE 33 3. ALL PAVEMENT CUTS, CONCRETE OR ASPHALT, ARE TO BE REPLACED ACCORDING TO { 0 I BENCHMARK ELEV. 40.4C MBL 1 BOOK 2698 PAGE 806 STANDARDS OF THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION. CONTROL I � � % N r { 4LD . SHORING WILL BE ACCORDING TO OSHA TRENCHING STANDARDS PART 1926 SUBPART SCALE: 1" = 30' C304 f \\ STAGE 3 � P, OR AS AMENDED. PLAN �" 1 i x 0 15 30 60 ROOF LEADER SCHEDULE STORM DRAINAGE SCHEDULE FROM TO SIZE (IN) MATERIAL LENGTH (FT) SLOPE (FT/FT) INV OUT (FT) INV IN (FT) FROM TO SIZE (IN) MATERIAL LENGTH (FT) SLOPE (FT/FT) INV OUT (FT) INV IN (FT) EYP Architecture & CO-12R CO-11R 6 inch PVC 13 0.0373 41.50 41.00 CI-9 CI-2 15 inch RCP CLASS IV 81 0.0050 38.97 38.57 / �� ,," � ` /, Engineering, PCYP / CO-11R DI-5 6 inch PVC 15 0.0326 41.00 40.50 CI-8 CI-2 15 inch RCP CLASS IV 40 0.0050 38.77 38.57 /�- // 811 West Hargett Street DITCH A - i` -f�� s. / Q ,� Raleigh, NC 27603 WYE-10R CO-9R 6 inch PVC 13 0.0101 41.00 40.87 CI-7 CI-6 15 inch RCP CLASS IV 23 0.0052 40.26 40.14 SEE DETAIL 9/C705 / `,' / / f �Q v5 Tel: 919 833 8818 CO-9R WYE-8R 6 inch PVC 15 0.0101 40.87 40.72 CI-6 DI-5 15 inch RCP CLASS IV 41 0.0051 40.14 39.93 // J %�Td Fax: 919 833 6898 WYE-8R WYE-7R 6 inch PVC 24 0.0138 40.72 40.39 DI-5 DI-4 15 inch RCP CLASS IV 46 0.0050 39.93 39.70 q� �, eypae.com Illp WYE-7R CO-6R 6 inch PVC 6 0.0150 40.39 40.30 DI-4 MH-3 15 inch RCP CLASS IV 123 0.0050 39.70 39.08 12' WIDE GRAVEL MAINTENANCE / // �'F,y� SjT J� �l CONSULTANTS: CO-6R MH-3 6 inch PVC 38 0.0151 40.30 39.73 MH-3 CI-2 15 inch RCP CLASS IV 102 0.0050 39.08 38.57 ACCESS; 6" COMPACTED ABC OVER WOVEN GEOTEXTILE / Structural Engineering: CO-5R WYE-4R 6 inch PVC 30 0.0100 41.50 41.20 CI-2 FES-1 15 inch TRCP CLASS IV 13 0.0055 38.57 38.50 (MIRAFl 500X, OR EQUIVALENT) SR 1502 WYE-4R WYE-3R 6 inch PVC 42 0.0100 41.20 40.78 OVER COMPACTED SUBGRADEr ,; / Stewart Engineering, Inc. STRUCTURE LEGEND: 421 Fayetteville St., Suite 400 WYE-3R WYE-2R 6 inch PVC 30 0.0101 40.78 40.48 CI - CURB INLET / '>, // Raleigh, NC 27601 WYE-2R CO-1R 6 inch PVC 16 0.0100 40.48 40.32 CO - CLEANOUT / DI - DROP INLET / Tel: 919 380 8750 CO-1R CI-8 6 inch PVC 80 0.0103 40.32 39.50 MH - MANHOLE / N Fax: 919 380 8752 WYE - WYE CONNECTION FYE - FLARED END SECTION / ;'%" / VICINITY MAP N.T.S. / Civil Engineering/ Landscape Architecture: / // TOPOGRAPHICAL AND BASE SURVEY INFORMATION OBTAINED FROM Cole Jenest & Stone, pa HANOVER DESIGN SERVICES, P.A.. THIS INFORMATION WAS ORIGINALLY 119 East Hargett Street, Suite 300 ISSUED AND SEALED BY GREG A. WAYNE; NORTH CAROLINA PROFESSIONAL LAND SURVEYOR SEAL: L-2876, ON JULY 2, 2013. Raleigh, NC 27601 PROPOSED IMPROVEMENTS FOR BRUNSWICK MEDICAL CENTER PARKWAY Tel: 919 645 5964 SHOWN PER PLANS FOR 'BRUNSWICK NOVANT MEDICAL CENTER ROADWAY ' Fax: 919 719 1819 / EXTENSION PROJECT,' PREPARED BY SITE SOLUTIONS, P.A., DATED FEBRUARY 21, 2014 Plumbing Mechanical Electical & Fire Protection: �. EYP, Inc 420-1-A The Parkway LEGEND Greer, SC 29650 / TRACT B Tel: 864 334 0997 MAP CABINET 48 PACE 33 s �� � / SYMBOL DETAIL BOOK 2698 PAGE 808 � � / Fax: C-LD N,, 7 / PROPOSED CONTOUR -/ 11////////II4l N+nCA � g��� .'�POR '• Z �� �ti�'� / _ A L�l r� SEAL F'. Cn _ r Q� r PROPOSED INDEX CONTOUR - Z�� C-1031 2� ; �� z v p�� �� /CAR G I N_e q-.'•���� .. ODD EXISTING CONTOUR ����nnu+►++�`�10 06 14 FU ST N PARTNERS & CAMERO / / PROPERTIES,IES, LTC 41 / OS 2614 PC 989 P8 48 PC 64 100.00• PJ PROPOSED SPOT ELEVATION -/-38.0 39 W -LD 24 00 .way // r RIP RAP APRON SEE DETAIL 15/C701 EXISTING SPOT ELEVATION / / .. X�l° SF�F \.... .. �y 1 REVIEW COMMENTS 1 '4 ti� p TRACTCO S 06/ 1/14 BRUNSWCK COUNTY HOSPITAL, LLC \, // \' MAP CABINET 4" PAGE HP. PROPOSED HIGH POINT -/- TRACT / 394s FEs-1 BOOK 2696 P AGE B08 � / \ 2 BID DOCUMENTS 07/02/14 MAP CABINET PAGE 3 BOOK 2751 PACE 09 � �' I<S. RIM:38.50 -w. 9 a1 t 3 ADDENDUM 1 07/25/14 r 38.25 cI-2 ♦ 4 REVIEW COMMENTS 07/31/14 / 93C-LD ,� PR� CSED DRAINAGE SWALE -/- RIM 41.00 ��� 5 NCDENR EROSION CONTROL 10106114 CI 9 '� ^ / RIM:41.00 •. ` 6 NCDENR STORMWATER 11114114 \41.75 'QCp 225 PROPOSED STORM DRAINAGE 1O/C702 41.60.�Q r 41.6 \ 25 41.7 CI PROPOSED CURB INLET 1,2,8/C704 RIM:41.70 41. •\ MH-3 41.204iA \ ... RIM:42.50 7 1 C9, 4 42.50 D ' f ♦ I # Revision Date 1.5o PROPOSED DROP INLET 3,9/C704 42-10 41. DITCH B 70, SEE DETAIL 9/C705 EXISTING CI-72 r' l err. MH SCO I D#. 07-07054-02J r 43.2842.78 � � � ��,♦ �• f3� PROPOSED MANHOLE 10,11/C703 43 g,� 37 a f • , ° 43.2 s '43.50 t,Q CO 1�r �� / / ! - ROOFDRAIN LINE WITH CLEANOUT 5/C702 WYE 7R gr ' WYE-8 R 88 v' t GRADING AND DRAINAGE NOTES: 0 1. ANY GRADING BEYOND THE DENUDED LIMITS INDICATED ON THE CONSTRUCTION DOCUMENTS IS A VIOLATION AND IS SUBJECT TO �' f ���� WYE 2R �•� 275 r CONSTRU �j ����� \ s � A FINE. Community Service k �z WYE-10R , ten a � if / � lv WYE 3R _75 2 1 42.77 O O 43 25 ' ING MORE AN 1 %� // '� EROSDION CONTROL APLAN N ISAAR VIOLATION TAND IS SUBJECT TO A Learning Center #8 •� .m i FINE. V � � - , OTC � O •""� I DI 4 TIE FOUNDATION �� �� okel IM�. m. 30 �'� O p `11 "e 3. APPROVAL OF CONSTRUCTION DOCUMENTS IS NOT AN Brunswick DRAIN TO DI-5 O 4 a � vx ' -.; O O AUTHORIZATION TO GRADE ADJACENT PROPERTIES. WHEN FIELD CONTINUOUS FOUNDATION �-' ^b' N -' -..,, CONDITIONS WARRANT OFF-SITE GRADING, PERMISSION SHALL BE � DRAIN PER ARCHITECTURAL N, o100 V / „M.,,....,.v PLAN _ / J o 1„104167C3 OBTAINED BY CONTRACTOR FROM THE AFFECTED PROPERTY East Carolina University 2 CO-12R �,� �✓O�� WYE-4R f / 39.25 N �` o �5: E;2225064,47 OWNERS \ \ 00 N�AN a 1985 4 School o Dental Medicine . IN ORDER TO ENSURE PROPER DRAINAGE, CONTRACTOR SHALL } E, CT��1"JCL' MAINTAIN A MINIMUM OF 0.5� SLOPE ON THE CURB. , ° , .. � ��� , �PBrunswick County NC .. 43.0 ;. - R A� 5. ALL SIDEWALKS, STOOPS, TERRACES AND OTHER PAVED AREAS , \ �i j `3 REP / TELEGRAPH COMPANY CO-5R >. 6 /°""° AMERICAN TELEPHONE AND SHALL SLOPE AWAY FROM BUILDINGS) AT 2.0% MAXIMUM. l I DI-5 i rw 1 41 / / �, Q / / ♦ 20'EASEMENT D B 719 PG. 1049 RIM: 00 42501 43 6. CONTRACTOR SHALL CONTACT INSPECTOR 48 HOURS BEFORE ADJUST EXISTING DROP i 1 75 �U�y �i / /� CONSTRUCTION. 43.25 c� 43 INLET GRATE TO PROPOSED , 43.50 GRADE RIM = 41.85 \ oFOR- 43.50 p A 7. SHALL LCCOO COORDINATE NTH A GEOTECDHN CEAL ENGINEER OONRTHEOR DATE; 9.50'W CI-6 Fr 0710212014 � :,°�: �N ��,� � ,� � SUITABILITY OF SOILS°41 � � / � I PLANNED FOR THESE SLOPES AND FOLLOW f� RIM:42.75 4325 ♦ RECOMMENDATIONS TIONSET FORTH BY THE GEOTECHNICAL ENGINEER SCALE: As indicated 4275`, CONSTRUCTION. ALL SLOPES SHOULD BE TRACKED ' / TOP TO BOTTOM AND STABILIZED WITH NORTH AMERICAN GREEN EYP PROJECT NO.: 6013031.01 S150, OR APPROVED OTHER, STAKED TO MANUFACTURER'S '�`c RECOMMENDATIONS. TOP SOIL PLACEMENT ON SLOPES SHALL BE 4275 TIE UNDERDRAIN TO INSTALLED IN A BENCHED PATTERN. I / ✓ ROOF DRAIN HEADER r � 43.00 / INV = 41.20 ° ; CI-7 oo °< r ."�� 4" PERFORATED PVC UNDERDRAIN - RIM:42.75 �p � 4 . . STORM DRAT d p r e x, SEE DETAIL 12/C705 AGE NOTE DESIGNED BY. AWK k� � ' P q 1 i, � � '��'gyp 4 4 �"'b OK ;r � 4 CONNECT BUILDING DOWNSPOUTS 1. ALL PIPE TO BE INSTALLED AND BEDDED PER MANUFACTURER'S DRAWN BY: - i �� 9 N, TO ROOF DRAIN HEADER, TYP SPECIFICATIONS. REFERENCE DETAIL 10, SHEET C702. I SEE DETAIL 5/C702 CHECKED BY: RTF 2. NO VEHICULAR TRAFFIC SHALL BE ALLOWED ACROSS PIPES UNTIL A ( $ / JOHN C. COBLE MINIMUM OF 2' OF COMPACTED COVER HAS BEEN INSTALLED. 3- ALL PIPES AND STRUCTURES IN PUBLIC RIGHT OF WAYS TO MEET PROPOSED 40' ACCESS i ( #i / ✓f" ' / .,� r `y �° NCDOT STANDARDS. ALL PIPE TO BE RCP IN PUBLIC RIGHT OF WAY. AND UTILITY EASEMENT r 2d k s� ..,. 7� ^ �� 4. ALL CONSTRUCTION TO MEET OR EXCEED NCDOT AND LOCAL / � e .w STANDARDS. f $ r IN, PROPOSED SIGNAGE GRADING EASEMENT AREA i I � 'TRACT B � AND 11 E 1 (CONTROL) ��`� 1 MAP CABINET 48 PACE 35 ; � I BE 10s MARK ELEV. 4t0.46 MSL '' BOOK 2698 PAGE. 808 _ NC401�' scA�E� 1�� 30� DRAINAGE �� 0 15 30 60 PLAN STORM DRAINAGE SCHEDULE \ _s,. FROM TO SIZE (IN) MATERIAL LENGTH (FT) SLOPE (FT/FT) INV OUT (FT) INV IN (FT) EYP Architecture & � '� � Engineering, PC OCS-1 FES-2 24 inch RCP 57 0.0873 28.00 23.00 g ' ; ti fi , o s , _ RIP RAP APRON 811 West Hargett Street * YP / INSTALL 0—RING JOINTS ON 24" RCP FROM OCS-1 TO FES-2 l/ SEE DETAIL FES-2 Q� �� Raleigh, NC 27603 r �� _ µ, 7 \ 15/C701 �Q �S Tel: 919 833 8818 jr OCS-1 " RIM: ax: 919 833 6898 Al s eypae.com 'r IS01 CONSULTANTS: / Structural Engineering: 1 / 9 \ SR 1502 Stewart Engineering, Inc. OUTLET CONTROL STRUCTURE 421 Fayetteville St., Suite 400 SEE DETAIL 8/C705 Raleigh, NC 27601 N Tel- 919 380 8750 V_ CONSTRUCTED WETLAND Fax: 919 380 8752 W � SEE DETAIL 3 C705 N.T.S. / VICINITY MAP l_ PERMANENT POOL: 33.0 Civil Engineering/ Landscape Architecture: TOPOGRAPHICAL AND BASE SURVEY INFORMATION OBTAINED FROM Cole Jenest & Stone, pa HANOVER DESIGN SERVICES, P.A.. THIS INFORMATION WAS ORIGINALLY 119 East Hargett Street, Suite 300 ' + ISSUED AND SEALED BY GREG A. WAYNE; NORTH CAROLINA IMPORT SELECT FILL REFER TO C601 FOR PROFESSIONAL LAND SURVEYOR SEAL: L-2876, ON JULY 2, 2013. Raleigh, NC 27601 MATERIAL FOR BERM f PLANTING AT WETLAND BASIN CONSTRUCTION 1 \ "" •.AA PROPOSED IMPROVEMENTS FOR BRUNSWICK MEDICAL CENTER PARKWAY Tel: 919 645 5964 SHOWN PER PLANS FOR "BRUNSWICK NOVANT MEDICAL CENTER ROADWAY Fax: 919 719 1819 R 0 " PREPARED BY SITE SOLUTION P.A. ATED .- EXTENSION PROJECT, S A. \ FEBRUARY 21, 2014 Plumbing Mechanical Electical & Fire Protection " + EYP, Inc + f V +f + ++++ + f f ++ ++ + v 420-1-A The Parkway f + + �� v LEGENDGreer, SC 29650 f + ++ f +� + f + + \ Tel 864 334 0997 + + +/ + SYMBOL DETAIL + + + + \ Fax: + + + + \ \\ ���nui►►►f + PROPOSED CONTOUR —/— �� ►iq \ + + & 5 ��� �� ........... + f \ J + �``` SEAL�? <^O?tn =OQ�OF O'L��y \ f+ + + +f f + ++ + f " .,, 1pp PROPOSED INDEX CONTOUR —/— 2 _ C-1361 ; 0 J �--� �s�,.�-� 31 Jfl All ODD � / /EXISTING CONTOUR —/— ���unu1►���` 10 06 14 Y N " I 100•00• PROPOSED SPOT ELEVATION -- \ v. 61 \ EXISTING SPOT ELEVATION PROPOSED STORMWATER � —/ arm \ r NEASEMENT GRAVEL TU AROUND -A 1 REVIEW COMMENTS 06/11/14 AREA PROPOSED HIGH POINT 4- 1 § DOCUMENTS I 2 BID DOCUMEN 07/02/14 3 ADDENDUM 1 07125114 / I ��. �.. 4 REVIEW COMMENTS % a �— PROPOSED DRAINAGE SWALE —/— 07/31/14 , `" All 5 NCDENR EROSION CONTROL 10106114 .3 + 4, 4 A/r.., 4,. + 6 NCDENR STORMWATER 11114114 x w,, PROPOSED STORM DRAINAGE 1 / 702 a 4 r + I P j } a 12• WIDE GRAVEL MAINTENANCE „ ROPOSED CURB INLET 2,8/C704 ACCESS PATH; 6" COMPACTED ABC OVER WOVEN GEOTEXTILE 1- 3- - 4- F / 3 � � 4- (MIRAFI 500X, OR EQUIVALENT) T .,.„,, r - - I OVER COMPACTED SUBGRADE ,. / DI �' �� PROPOSED DROP ET 0 # REVISI011 Date s / P INLET 3,9/C7 4 3 i ... ..t. ..Y.. , f Af, ' �;,, / / / M H .,.. SCO I D#: 07-07054-02J © PROPOSED MANHOLE 10,11/C703 F ., mow. / CO ?J✓ y.. ROOFDRAIN LINE WITH CLEANOUT 5/C702 _ „. CO f ~f fr .1.. GPQ� I _ 4 � ro fV Community Service r I Learning Center #8 + _i Brunswick + East Carolina University �� °��,ti��� ,' School of Dental Medicine Brunswick County NC .. DITCH A a / _3. _;_ SEE DETAIL 9/C705 \ y f / DATE: 07/02/2014 / - // SCALE: As indicated / EYP PROJECT NO.: 6013031.01 DESIGNED BY: AWK DRAWN BY: - i/ CHECKED BY: RTF g. __ GRADING t, fr N AND C402 SCALE: 1" = 30' D E y RAI NAG - PLAN '� '� �� 0 15 30 60 „r / ,r; , / r g. s 7 u 1 ie 6 , s ; , ,< t 1 / re & Architecture .. " i{ ,. � Engineering, PC i { i +� Street YP / � � _-' � ,,..,..�„T , " 811 West Hargett `?, z v� ` ` Q �� , � §; ' Raleigh NC 27603 Tel: 919 833 8818 , • Fax: 919 833 6898 rusk"( f '` / /„ Jill eypae.COm I : 4, y /y CONSULTANTS. a w . d. .-CGI Structural Engineering: s. „ 4. g, k t 502 Enginee ,....m,....,, ..3 Suite 400 .., 421 Fayetteville St Engineering, Inc. �„ v, u = Raleigh, NC 27601 � I , a / - ��, N Tel. 9 380 8750 , T 22 MIN 210' SHEET FLOW � � 19"_,. '�,.,. v ' r , 1300 CHANNEL FLOW �' µ f/ 0 8752 _ , , ,. � _�- _ Fax. 919 38 ..... .,. ,, N.T.S. F VICINITY MAP mG Civil Engineering/ Landscape Architecture. ape Cole Jenest& Stone, TOPOGRAPHICAL AND BASE SURVEY INFORMATION OBTAINED FROM e, a " , ' ,.,. ♦ >} J # # ` a / HANOVER DESIGN SERVICES, P.A.. THIS INFORMATION WAS ORIGINALLY 119 East Hargett Street, Suite 300 a ♦. I \ _< ,, " ', { ISSUED AND SEALED BY GREG A. WAYNE; NORTH CAROLINA g♦ / "� PROFESSIONAL LAND SURVEYOR SEAL: L-2876, ON JULY 2, 2013. Raleigh NC 27601 PROPOSED IMPROVEMENTS FOR BRUNSWICK MEDICAL CENTER PARKWAY Tel: 919 645 5964 ,., w l ♦ 40 -- SHOWN PER PLANS FOR BRUNSWICK NOVANT MEDICAL CENTER ROADWAY Fax: 919 719 1819 PROPOSED PROPERTY 2.32 AC \ ♦ - �` EXTENSION PROJECT," PREPARED BY SITE SOLUTIONS, P.A., DATED EXISTING WOODED AREA °�6.. � ♦ _ 1% FEBRUARY 21, 2014 Plumbing Mechanical Electical & Fire Protection: ' b Inc I v v All ..., k,. 420�I-A The Parkway LEGEND Greer, SC 29650 ` q� \\ �• — ._ _ is L IL SYMBOL DETAIL Tel. 864 334 0997 I i I Fax: OFFSITE DRAINAGE \ �� .AM ftm �� DRAINAGE DIVIDE —/— ��������►� UNDEVELOPED LOT 1 \ \ //N//UI ���� ,w, ,, 0.93 AC M , ® �. N / ` m I � �� O�RiPCOgRRqFAI � \�� 2••�°�ESSi,,,,. =ON _ % 03 Sl ` - F • O , OFFSITE DRAINAGE _ -- — — - — -- — — i �'•-;;— — — — �� �� •,�. '•. 1 N :�w��• 1 WOODED AREA ���� /���� ��� ��D ��%% 06 14 4.62 AC ;,� ��111nnu1%0 s OFFSITE DRAINAGE / N WOODED AREA ♦ \ ® gre 1 0.45 AC � '� � ♦ � _ 0 ® //7 Mom Iftwft ,. Iftiftftftft II 42 I • I ♦ ♦ f , a s 1 REVIEW COMMENTS 06111114 _. 2 BID � g DOCUMENTS 07102114 ,a,f "; � a ..`",az g '"'...,. ♦ ......_.... / ' n. .# a, r; #, # rb' y, k, i y K .,, ,{ z t f I ♦'� '"µ 3 ADDENDUM 1 07/25/14 wu" W 4 REVIEW COMMENTS 07/31/14 PRE DEVELOPMENT DRAINAGE CONDITIONS l"y 5 NCDENR EROSION CONTROL 10106114 t� I � � ,- � y " r rt 6 NCDENR STORMWATER 11114114 t t 0 ,g y If ' +gyp OSt= ",,� PRO 13�„,.H.,,..,, � _ �� CONSTRUCTED . WETLAND 1 1 t „ „ y px $ t :, # Revision Date r / ZY oo SCO I D#. 07-07054-02J ri Fi r e 10 w w g s ! • • / „ , , gk d /E I , X , , s E '� ^ / 5: ,� J 1 �,,, / {/ — „_, ! a A ti , 1 / s f i I x WO Milk n PROPERTY NOT DETAINED � Community 0.20 AC ea r a � �" ti� m .14 011 _; a y. '„ J N r Brunswick -ECU SCHOO1,01 bENTIST92V-' „d✓,a ` 1 .. i' OFFSITE DRAINAGE SER CG LEARNING CENTER `s `d.. ,,♦ % ,. F.F.E.44 0 UNDEVELOPED LOT \ I „§. � as Carolina University ;3 PROPOSED PROPERTY ~-- ''�"° NOT DETAINED ,;, .,. • ,. � �, W�, �;�� " -� ,,, � � ..-- -��,�, _ �, ._.,.._. School of Dental Medicine .,, , I 0.57 AC " y, TO WETLANDS v v ` �'' `- 2 12 AC \ , n loft Rol Brunswick County N 3,500 SF e p ION ......._ � (PHA AREA /� o v \ \ � 77 150 SHEET FLOW / 1 1500' CHANNEL FLOW s ` - - -- -- --�`� '�� ATE W.m�, v OFFSITE DRAINAGE �\ - F~' �` � 07/02/2014 UNDEVELOPED LOT _ 0.36 AC " t' -- - - -- - - — , - . SCALE: As indicated OFFSITE DRAINAGE I EYP PROJ ECT NO.. 6013031.01 .,.. .> � ,,,,, � `. � fr,. � ' ♦ TO WETLANDS ry ` X 4 62 AC ♦ I �. N WOODED AREA I 0.45 AC OFFSITE DRAINAGE �� 7 # I q tom. ' ♦ M 1 ' '^` ,_ .. ♦ DESIGNED BY: AWK 4114 ;` ', � ♦ 1 DRAWN BY: - I4l, CHECKED BY: RTF PRE AND POST I � � e 7, Sd ` i j{ p Y amp M ♦ ti y DEVELOPMENT � 7 � x C403 DRAINAGE ♦ _ SCALE: 1"=60' ti `- POST DEVELOPMENT DRAINAGE CONDITIONS / _ � , �� � �� d #� CONDITIONS . a 30 60 120 v / EYP Architecture & / Engineering, PC 811 West Hargett Street 12"x6" TAPPING b \ / Q� Raleigh, NC 27603 SANITARY SEWER SCHEDULE M _SLEEVE AND VALVE FIRE HYDRANT ASSEMBLY Q BY OTHERS ' OS Tel 919 833 8818 FROM TO SIZE (IN) MATERIAL LENGTH (FT) SLOPE (FT/FT) INV OUT (FT) INV IN (FT) PIPE Fax: 919 833 6898 " TAPPING SADDLE W� 2 CORPORATION STOP TAPP � CO-3 CO-2 4 PVC 34 0.0293 38.00 37.00 PIPE-3 / TAPPING SADDLE W/ 1.5" CORPORATKHV STOP SIP IS�I CO-2 CO-1 4 PVC 42 0.0292 37.00 35.78 PIPE-2 / r c eypae com CO-1 EX-SSMH 4 PVC 27 0.0293 35.78 35.00 PIPE-1 / f �� POST INDICATOR EIEATOR / \ SjT J°, CONSULTANTS: / I ��� �� � • �' DETAIL 3/C703 / I / SR 1502 Structural Engineering: Stewart Engineering, Inc. PROPOSED 6" REDUCED 421 Fayetteville St., Suite 400 / PRESSURE PRINCIPLE BACKFLOW o /PREVENTION ASSEMBLY Raleigh, NC 27601 / 2 BALL VALVE / SEE NOTE 3. N Tel: 919 380 8750 MAP N.T.S. " Fax: 919 380 8752 PROPOSED 2 WATER METER FOR 9 FIRE R CONNECTION / VICINITY AT VAUL WITH TH CHECK VALVE Civil Engineering/ Landscape Architecture: DOMESTIC SERVICE; SEE NOTE 1. / SEE DETAIL 2/C706 / ,' TOPOGRAPHICAL AND BASE SURVEY INFORMATION OBTAINED FROM Cole Jenest &Stone, pa HANOVER DESIGN SERVICES, P.A.. THIS INFORMATION WAS ORIGINALLY y � ISSUED AND SEALED BY DREG A. WAYNE; NORTH CAROLINA 119 East Hargett Street, Suite 300 PROFESSIONAL LAND SURVEYOR SEAL: L-2876, ON JULY 2, 2013. Raleigh, NC 27601 PROPOSED 1.5" WATER METER Tel: 919 645 5964 FOR IRRIGATION SERVICE; SEE PROPOSED IMPROVEMENTS FOR BRUNSWICK MEDICAL CENTER PARKWAY SHOWN PER PLANS FOR "BRUNSWICK NOVANT MEDICAL CENTER ROADWAY Fax: 919 719 1819 NOTE 2. / �� / l EXTENSION PROJECT," PREPARED BY SITE SOLUTIONS, P.A., DATED f' 2" BALL VALVE �// \ FEBRUARY 21, 2014 Plumbing Mechanical Electical & Fire Protection: EYP, Inc ill PROPOSED 1.5" REDUCED °� fr` 420-1-A The Parkway PRESSURE PRINCIPLE BACKFLOW / �i f PREVENTION ASSEMBLY a LEGEND Greer, SC 29650 / / \. SEE NOTE 5. / Tel: 864 334 0997 1 SYMBOL DETAIL PROPOSED 2.5" REDUCED ' Fax: '£ PRESSURE PRINCIPLE BACKFLOW PREVENTION ASSEMBLY EXISTING WATER MAIN / / , __. SEE NOTE 4. � �� C q R �� `� REFER TO IRRIGATION PLAN & STD? `�,OQ ESS��C�� • FOR CONTINUATION,`/ �? SEAL r� �� .'a�� y��. v PROPOSED 12" WATERLINE INSET 1 SCALE 1 10 - EXTENSION BY OTHERS ' PROPOSED WATER LINE -/- J a c 10�°P \ " PROPOSED FIRE HYDRANT G ` 1��' t���O %, .T�yC I NLF;.S�(c,��� / LD ASSEMBLY BY OTHERS, ' ' / �\ EXISTING SAN. SWR. LINE AND MANHOLE �������►►1� 10/06/14 r 0,\ „ / , , PD /PROPOSED BLOW-OFF 3'i�� �, BY OTHERS �� CO PROPOSED CLEANOUT 2/C702 y � y �� \ ` POST INDICATOR VALVE \ „ SEE INSET 1 FOR WATER \ C-LD EXISTING FIRE HYDRANT -/- / DISTRIBUTION CONNECTION C-LD A� ell p 2.5"X2.5"X4" FREE STANDING FIRE PROPOSED 103t LF \ e� OF 4" PVC SAN. ® - tII DEPARTMENT CONNECTION WITH \ 1 REVIEW COMMENTS 06/11/14 CHECK VALVE AT VAULT; SEWER LINE / SEE DETAIL 2/C706 PROPOSED FIRE HYDRANT 2/C703 2 BID DOCUMENTS 07102114 3 ADDENDUM 1 07/25/14 DROP WATERLINES UNDER PROPOSED \ 9 � '' STORM DRAIN. PROVED 1' MINIMUM PROPOSED 8" SANITARY CO-3 CLEARANCE, TYP. SEWER EXTENSION BY OTHERS RIM: 43.40 r' ♦ 4 REVIEW COMMENTS 07131114 PROPOSED 130t LF OF „q PATCH PAVEMENT AND CURB „- 2.5" PVC SDR-21 DOMESTIC LINE � \ 5 NCDENR EROSION CONTROL 10106114 AT TRENCH CUT FOR SEWER CO-2 / INSTALL NEW 4" TAP RIM: 43.20 REFER TO IRRIGATION ' PROPOSED 171f LF \ i OF 6" DIP FIRE LINE �� 6 NCDENR STORMWA TER 11/14/14 AT EXISTING MANHOLE PLAN FOR CONTINUATION \ INV=35.0 OF IRRIGA1ON SERVICE EXISTING SSMH RIM=40.10 / �_, \ �. (2) 11.25' BEND INV=33.12EXISTING PIEDMONT NATURAL GAS MAIN �' "� �' (2) 90 BEND, TYP. ♦ ` EXISTING SSMH \ / WATER DISTRI BUTION NOTES f RIM=40.54 "�� # Revision Date INV=32.72 Q °��r ` \ �' 2" DOMESTIC WATER METER FURNISHED AND INSTALLED BY EX-SSMH / \ � RIM. 40.'40 i A CONTRACTOR IN BELOW GROUND VAULT PREPARED BY CONTRACTOR. METER SHALL BE SENSUS AMR AMI PER BRUNSWICK COUNTY ' ������ ~m . � \ ♦ STANDARDS. REFER TO DETAIL 1/C705 SCO ID#. 07-07054-02J , h ,. ; � -.--- 2. 1" IRRIGATION WATER METER FURNISHED AND INSTALLED BY 4 CONTRACTOR. .„,� ,, -�, \;� CONTRACTOR IN BELOW GROUND VAULT PREPARED BY / 4 r ' ���� \ \ METER SHALL BE SENSUS AMR/AMI PER BRUNSWICK COUNTY -• / , / �" STANDARDS. REFER TO DETAIL 705 4"/P ;Mr �? � 4 '>� \ 3. 6" REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTION M, / / ; " 4 : ' >O� = p �Q / ASSEMBLY INSTAL-ED ABOVE-GROUND WITHIN INSULATEDnE I •-, v 4 / C / ENCLOSURE. SEE DETAIL 702 �" "` ., , Z �` � � � ""dam „' 9/C Ov Q��; Q / aft/,,. ' � / 4. 2.5" REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTION \ / / C0_1 r'O`r� „ h� �0�� / ASSEMBLY INSTALLED ABOVE-GROUND WITHIN INSULATED / �� /"" ENCLOSURE. SEE DETAIL 3/C702. Community Service RIM: 41.00 V - `5 EXISTING 8" O�J ' ;r 4QQ Q /«� � / SANITARY SEWED, �� �� / / - / 5. 1.5" REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTION M..M ,`», / ABOVE-GROUND WITHIN INSULATED j C y - Learning Center #8 ��-. ESCLOSUREINSSEELDDETAABO�C7020 - e, 6. CONTRACTOR TO LOCATE TIE-INS TO ALL BUILDINGS BASED ON PLUMBING PLANS. Brunswick / 7. TAMPER SWITCHES TO BE INSTALLED ON THE FIRE LINE BACKFLOW EXISTING �/ / ` � / /} � / - - PREVENTER. INSTALL 3/4" CONDUIT FROM FIRE LINE BACKFLOW East Carolina University UNDERGROUND / ;�� / _ ;� � q , , '"'"'�� /.. ~` y ELECTRIC / \a G�c'rs / / VAULT TO BUILDING ALARM SYSTEM INSIDE BUILDING. COORDINATE School of Dental Medicine / / a \�F / WITH ALARM SYSTEM MANUFACTURER. OFFn EXISTING FIRE \ T , Off' 8. THERE SHALL NO TAPS, PIPING BRANCHES, UNAPPROVED �`�� HYDRANT (FLOW / / '� " - ,,.ie "y / PROPOSED GAS METER BYPASS PIPING,EHYDRANTS, FIRE DEPT. CONNECTION POINTS, OR " c- � " - BY UTILITY Brunswick County NC TEST HYDRANT / / �, \ / / `" OTHER WATER USING APPURTENANCES CONNECTED TO THE SUPPLY ELEVA11ON = / / / / \ / / "/ LINE BETWEEN ANY WATER METER AND ITS REQUIRED BACKFLOW 39.16) 4 / / - - PREVENTER. meµ, 9. CONTRACTOR IS RESPONSIBLE FOR COORDINATING WITH BRUNSWICK PROPOSED GAS SERVICE COUNTY PUBLIC UTILITIES FOR ALL PROPOSED WATER AND /« BY UTILITY; SANITARY SEWER CONNECTIONS. CONTRACTOR TO COORDINATE PROPOSED TRANSFORMER DATE: / + INSTALLAl10N �", � � ON CONCRETE PAD. REFER 10. PUBLIC UTILITIES CONTRACTORS CONSTRUCTING FIRE SERVICE MAINS 07/02/2014 /, \� TO ELECTRICAL PLAN FOR FOR BUILDING CONNECTION TO FIRE SPRINKLER SYSTEMS SHALL SCALE: As indicated EXISTING - SPECIFICATION TERMINATE THOSE LINES AT A FLANGE, CAP, PLUG, OR VALVE / } 12" PVC INSIDE THE BUILDING ONE FOOT ABOVE THE FINISHED FLOOR. ALL EYP PROJECT NO.: 6013031.01 WATERLINE j / r f / I FIRE SERVICE MAINS SMALL COMPLY WITH THE NFPA STANDARDS \ ��ON MUST OO FOR FIRE SERVICE MAINS AS INCORPORATED INTO AND MADE a i �JG 0 kL I TY pRN,�o APPLICABLE BY VOLUME V OF THE NORTH CAROLINA BUILDING CODE. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE v COORDINATION OF BUILDING AND SITE UTILITY CONTRACTORS SO THAT HYDROSTATIC TESTING OF THE FIRELINE MAY OCCUR TO THE Q o TERMINATION POINT WITHIN THE BUILDING. ICI I DAILY WATER USAGE: z DESIGNED BY: AWK I I •,�� -:., <`� MAXIMUM OCCUPANT LOAD: DRAWN BY: 155 PEOPLE I I $ AVERAGE OCCUPANT LOAD * ' BffiAORBYOUDIG! SUMMARY OF WATER MAINS CHECKED BY: RTF 18 STAFF + 34 PATIENTS = 52 PEOPLE _T , I 155 PEOPLE X 15 GPD/PERSON COIVTACPONB�ALi.CHN'1'l� Ill E = 2,325 GPD MAXIMUM WATER DEMAND I�0-632-4949 SIZE LENGTH I 52 PEOPLE X 15 GPD/PERSON 1. CONTRACTOR S FULLY RESPONSIBLE FOR CONTACTING APPROPRIATE PARTIES AND = 780 GPD AVERAGE WATER DEMAND ASSURING THAT EXISTING UTILITIES ARE LOCATED PRIOR TO CONSTRUCTION. 2.5" PVC 30 LF 6" DIP 171 LF I EXISTING FIRE HYDRAI°T 1 L� C-LD 2. CONTRACTOR S RESPONSIBLE FOR PLACING BARRICADES USING FLAG MEN, ETC. AS III (PRESSURE TEST HYDRANT) NECESSARY T INSURE SAFETY TO THE PUBLIC. EYP / i I I APPROXIMATELY 420 LFy DAILY SEWER USAGE: WATER SOUTH PHYSICIANS PLAZA "" f FROM 15A NCAC 02T.0114: SEWER FLOW 3. ALL PAVEMEN CUTS, CONCRETE OR ASPHALT, ARE TO BE REPLACED ACCORDING TO DISTRIBUTION i 1 DRIVE INTERSECTION; £ = 250 GPD/PRACTITIONER/SHIFT STANDARDS OF THE NORTH CAROLINA DEPARTMENT OF TRANSPORTATION. ELEVATION = 40.99 '; r 6 PRACTICIONERS X 1 SHIFT X 250 GPD/PRACTICIONER/SHIFT SCALE: 1" - 30' IN SANITARY C501 y = 15CO GPD AVG SEWER FLOW 4. SHORING WILL BE ACCORDING TO OSHA TRENCHING STANDARDS PART 1926 SUBPART P, OR AS AMENDED. SEWER PLAN 0 15 30 60 y CALCULATIONS loor LANDSCAPE CALCULA EYP Architecture & ell Engineering, PC 5 PROJECT BOUNDARY BUFFERS ;a 811 West Hargett Street YP / NO REQUIREMENT (0.0 OPACITY PER ZONING; Q� Raleigh NC 27603 '' , / PROPERTY = C-LD, ADJACENT PROPERTY = C-LD), Q ' a, ' STCRMWATER BMP OFF-SITE, v5 Tel: 919 833 8818 w e� �, ✓ / SEE INSET A FOR PLANTING PLAN AND SEE BRUNSWICK CO. UDO SECTION 7.2.9 - REQUIRED BUFFERS CONTEXT MAP FOR LOCATION ^ Fax: 919 833 6898 STREET BUFFERS ` �° ° a.; ., �� s eypae.com ,[ e FUNSTON PARTNERS & CAMERON REQUIREME TS (PER BRUNSWICK CO. LIDO ARTICLE 7.2 - REQUIRED BUFFERS): � 'P ISO 100' BUFFER PROPERTIES, LTD SIT 1 CONSULTANTS: VINTER�/AL„"#4 =,..�,� t. � °/ DB 2614 PG �, ': FOR COLLE TOR THOROUGHFARE STREET BRUNSWICK MEDICAL CENTER PARKWAY): J - 20' PLANTED BUFFER PP 48 PC - 1 CANOPY TREE PER 100 LINEAR FEET OF PROPERTY FRONTAGE; Structural Engineering: - OFF-SITE DITCH TO BE STABILIZED WITH NORTH AMERICAN - 2 UNDERSTORY TREES PER 100 LINEAR FEET OF PROPERTY FRONTAGE; SR 1502 '• !' =,� GREEN SC 250 EROSION CONTROL MATTING, 62,000 SF OF Stewart Engineering, Inc. Po,a, - LANDSCAPE LOCATED WITHIN A 20-FOOT LANDSCAPE BUFFER (DEPTH OF BUFFER r y SEED WITHIN LIMITS OF OFFSITE DITCH DISTURBANCE M Y VARY PER GUIDELINES OF UDO ARTICLE 7.2.5) 421 Fayetteville St., Suite 400 OO ' ,~ Raleigh, NC 27601 Gip, ter" . ° F� - STREET TREES QUERCUS PHELLOS CALCULATIONS: g ' BY OTHERS, SEE FOR BRUNSWICK NOVANT Tel: 919 380 8750 MEDICAL CENTER ROADWAY EXTENSION PROJECT PREPARED TOTAL LINEAR STREET FRONTAGE FOOTAGE = 519.3' '1• � " / ;.:`• '"', � _; ..' TOTAL LINEAR DRIVEWAY WIDTH FOOTAGE = 68.5' �� F q �,• �,> � ��_.: � , ° ` _ 4- BY SITE SOLUTIONS, PA. Fax: 919 380 8752 TOTAL LINEAR FEET (LESS DRIVEWAY WIDTH) = 450.8' VICINITY MAP N.T.S. y ASi� REQUIREMENT: 5 CANOPY TREES, 10 UNDERSTORY TREES A F " T Civil Engineering/ Landsca e Architecture: tiP g TOTAL PROVIDED: 9 CANOPY TREES (STREET TREE PLANTING BY OTHERS, p RUN COUNTY HOSPITAL, DLO "`fi FACT B \ SEE S TE SOLUTIONS LANDSCAPE PLAN), 12 UNDERSTORY TREE-S '.'{ f ' .R. TOPOGRAPHICAL AND BASE SURVEY INFORMATION OBTAINED FROM Cole Jenest & Stone, pa TRACT A. " " T MAP CABINET 48 PAGE 33 \ �. .\ HANOVER DESIGN SERVICES, P.A.. THIS INFORMATION WAS ORIGINALLY 119 East Hargett Street Suite 300 AP CABINET 48 PAGEBON 751 PAGE 70 �\° I„S � � , :. _ _;;?. BOOK 295 PAGE 808 \ FOR PHYSICIAN'S PLAZA DRIVE EXTENSION: ISSUED AND SEALED BY GREG A. WAYNE; NORTH CAROLINA g 15' PLANTED BUFFER ® 0.2 OPACITY PROFESSIONAL LAND SURVEYOR SEAL: L-2876, ON JULY 2, 2013. Raleigh, NC 27601 1 ANOPY TREE, 1 UNDERSTORY TREE, AND 7 SHRUBS PER 100 LINEAR FEET :" `" ° \\ PROPOSED IMPROVEMENTS FOR BRUNSWICK MEDICAL CENTER PARKWAY Tel: 919 645 5964 CALC LATIONS: SHOWN PER PLANS FOR "BRUNSWICK NOVANT MEDICAL CENTER ROADWAY FaX: 919 719 1819 I ROADWAY = 145.1' TOTAL LINEAR FEET OF EXTENSIONEXTENSION PROJECT, PREPARED BY SITE SOLUTIONS, P.A., DATED •' / 2 MASW � '""' « �` REQUIREMENT: 2 CANOPY TREES, 2 UNDERSTORY TREES, 10 SHRUBS ", FEBRUARY 21, 2014 PlumbingMechanical Electical & Fire Protection: / � UNDERSTORY TREE 4 ILEP ' � `.��" ' ,,. �� � TOTAL PROVIDED SOUTHERN PORTION 2 CANOPY TREES, 3 UNDERS 0 S, - ` s ILEc , ' , ";, �,,, ..,� 13 SH uBs EYP, Inc PROPOSED PRIVATE STREET " �« 6 ILNP \ r 420-I-A The Parkway ` v 0o' BUFFER y XISTING PRIVATE ACCESS, UTILITY & DRAINAGE EASEMENT "PH r'SICIANS \ 1 MASW PLAZA DRIVE" J INTERI7AL #3 r ,4 y" «, \ - 19 ILES VEHICLE USE AREA (VUA) I I Greer, \ SEE INSET A SC 29650 MAP CABINET 48 PAGE 33 l ` �� WETLAND I Tel: 864 334 0997 606 f SOD °', „ CALCULATIONS: PLANTING PLAN \ 9 TOTAL PARKING SPACES (PHASE 1) = 35 /i�i I %/„i Fax 3,.;, /,. REQUIREMENT UIREMENT PER UDO 6.1 1 LANDSCAPED ISLAND MIN 144 SF , ( ) MAIN N T ,,.. 1 QUNU PER 20 PARKING SPACES, WITH 1 TREE (MIN 2" CALIPER ® 4.5' ABOVE GROUND) A SITE JQ,Qy € ,;;, 1 QUNU .. r ` �rtu�n►►► w 2 M ~`\ AND LOCATED WITHIN 150 FEET OF EVERY PARKING SPACE '- ���� q4A \ r . � 2 ULMA � � ,• 1^1 ���/ II♦j♦�� `J�� N CAIvO - LANDSCAPE ISLAND #1 CALCULATIONS: ���� J W� �•` �'•� 0 / 6 ULMA �� �c.S� & S _ O�'.�ESSi�' ���`� OOp ' ` " x ° ° ' 6 ILGS LANDSCAPE , v, TREES PROVIDEDTOTAL AREA = 606 ALLEGE ETLMSW®I Z 550 OF EVERYPARKING SPACE `�'\� .o�PpggT O�= _.�p �,�,.- y ISLAND 1. E f - ,,, SEAL = - Q r • ,,r. ,,: # ,`,' ' LANDSCAPE ISLAND #2 CALCULATIONS: I I J j C-1361 \ 8,315 sf SOD ✓ '°.°"' p CALCS ;`E TOTAL AREA = 447 SF, LOCATED W/IN 150 OF EVERY PARKING SPACE I I y C-103 Q: _, "° .. , ., .. 9 ,".'gas', , °r �^ ,g ,,..4 _ - x,H a. jf =O •O,p�. �2f- e411/P: :,`.',., , ,,,,, ,,,,,,,, / 7� s SOD „ 398 sf SOD TREES PROVIDED 1 ALLEE ELM ® 2.5 3" CALIPER ; ., „I O �/CAR�.• Cn �� �° ^.. %' � � ' •:� :, " '° - / � LANDSCAPE ISLAND #3 CALCULATIONS (ONLY TO BE BUILT IIF PHASE 2 �,� •� �� � ••�C I NEF': �` x a d L AREA = 218 S LOCATED N 150 OF �� . ... • '' `Z` . IS CONSTRUCTED): TOTAL F W/I ♦ �� ,,� IO•" \�```. EVERY PARKING SPACE � - J ♦III//////U� �i OD F � \ :;•. .`; "~ TREES PROVIDED = 1 ALLEE ELM 2.5-3" CALIPER NOT SHOWN ������► 10 06 14 N ON CURRENT P ONLY INSTALLED IF SE 2 IS B / , r •✓ ' � .'::°:°' r ., . , . ., . ,.BD.: �. ,, F:� .'.°e °�: LAN, PHA (NOT r " y ` T _ NTS (P 1) I CONTEXT MAP � TOTAL PROVIDED (PHASE 2 ISLANDS 3 TREES ., `°' (MEETS OR EXCEEDS REQUIREMENT) VS _; 9 ICES 1C 3 ILGS \ NDSCAPE - TOTAL PROVIDED (PHASE 2) = 3 ISLANDS, 4 TREES 1' , " NTER1/100­ 13U 2 �° �� 3 ILEP LAND #2, SEE o a #, , �LCS ,,. p. ', „ �; A �. a �� �:` �`" LEGEND DETAIL � 10 ILGS 1 QUNU ,` ' � " SYMBOL (� Q COCA D DSC � "� y �� `C E -• � PHA (� ,, � :::: ':•:~. ,:. .,, ,` °;° � hROPOSED TREE 7 7 4 y t G + �C 0 51 41`1 5 SPAW i O 1 E.� R VIEW COMMENTS S 06111114 f 3 CLE H , E f i �,� •. „ ti, g� 2 ASW �r , of 3 ILEC � � a � � � a: � � �� 2 BID DOCUMENT O / m r 07102114 , PROPOSED SHRUBS 13 7 4 f Q. 3 DD A END UM 1 07125114 N.1041 , r^ r rvk e'Y Nam'� J 4 E� �n REVIEW �. COMMENT y' S 07131114 , Y \ x err d f!. r Q „� W' f j 5 s° , , , • 2_ 4 • , „ PROPOSED SIGN PROPOSEDE SED A „ " � '� N,A, . 1 �,� 5 NCDENR EROSION CONTROL 10/06/14 lg ',•`• f 11 ILEP ! S �,.e`� ° ,;�� r �� , � � ° o 6 NCDENR STORMWA TER 11114114 •,. '.° ,;• _ , `: "" E TELEGRAPH COMPANY � WETLAND SHALLOW WATER - - J ~.5 ° • 6 AMERICAN TELEPHONE AND f i / yy 20'EASEMENT D.B. 719 PG. 1049 f / WETLAN f ;� .. , "».. . .. , .• , .. , ..:.. :•: •�n°6 : �. -'V D SHALLOW LAND - " IN O , x s. r � 6 1� 4� , D'• :.' ... .. ,,e ,. .ter w :,• .., . .��,,,,,., r 'n�°�' �� � � ' ILEP . ' ,_;,- ,,. . @ ,. �' .', ° • , •>., , ,.� Z \ f1 CHVI 61LNP ar •, fF , f r ,INTER L 1 .., -. x - ,: .. ,:. «, .H �,,.,. :,. ," '¢ \. # ,>..' ,`• : `° ;. \\ 7 CLEH # Revision D `, \ ate \ 20 I TVA o / :j tm K`'c f t ,wt ,4 , n*e, , S, MASW g , 4-� PLANTING NOTES f= 1. , a . .,/ ..., 1. -°°, '° " < '_^ 31 450 sf SEED / � C SIZE AND GRADING STANDARDS OF PLANT MATERIAL SHALL CONFORM TO THE LATEST ,O f t � , : x� '.; - , , . ,.: �'�. , ,, ., ., i ., / _, � , ,.. ` ' •� .• s 11 ' i �` ` ' 9� s � "` .: � `"` - .,°' o " �., -" "":.'': "°• �"" WY ,,�. ,,,�° `"� •, ,�, ,~� �,. s v EDITION OF "AMERICAN STANDARDS FOR NURSERY STOCK", BY THE AMERICAN ASSOCIATION eC,1 ° / y` / ,r, \ OF NURSERYMAN INC. .� f .. --,,. � ,. „ .5 vem'°^r"'n` >� .;�: .� s" .? ,..�, P. „�saa r.�°�.,, ^^'� '�` . �; "°� / � �.°,� \ '� 7 CALA 9 ILEP ITVA r � I \ OOKf � . , s "> °' . .� o�' ..; � 2. HEIGHT AND WIDTH SPECIFICATIONS ` ,.� -�" °° °p / ..`4�. � C (CATIONS INDICATED ON PLANT SCHEDULE SHALL f f r•� J ;s f „�„ ., ,�, .:, , ,., � �. ,. � , �" �,. ,, .= :, �� , .," . � •�.,.,� : ,�,«, ' , � � LL TAKE _m a�,, , , \ 3 MYCS STREET TREES -. N1 / '� ,a PRECEDENCE OVER CONTAINER SIZE AND CALIPER. 3 \ r, ULMA BY OTHERS, SEE SITE f �,; ;a ,f� ", , ,.,, ,�. :: ..• �,.~;,W. \ � , ., � `�� 2 CHVI ° SOLUTIONS LANDSCAPE PLAN , j .4,.,.,. 4 ILNP ° ;., ' '.�, � + + -� �%. ;` '� " "n. �\, '�' � 3. CONTRACTOR SHALL MOUND ALL PARKING LOT ISLANDS TO 8" ABOVE BACK OF CURB AT y ,, d' :" $ / .,. &,°•: :' THE CENTER OF ISLAND. CONTRACTOR SHALL SUPPLY .;f , ,�,« / ,.� ♦ ( .�\,+ `�,�.;~ L AND PLACE ADDITIONAL TOPSOIL IF / / P:� •a. �,. .., �'" ', NECESSARY FOR MOUNDING AS � , - ,,:� ' °: •„~°,° ;;, ,^`• � / .� ".~e ,;_ � °\ � INDICATED ON CONSTRUCTION DOCUMENTS. � ," , B ',}:p' _ +, .,6,,* „�.tea. / 1 Y ,./ �•,,r" �,.; �;vsE�" ` / ?„-'.,A `a. % / 'l�* p ,hey �\ PROPOSED 40 ACCESS irr f .,,.,. � �� , ., ;,. : , ., .- � s i _ , . ..: .. , : .-; ,m"."• ', f / ry � y£ , ,b ., x4 ,. r y` _ 4. CONTRACTOR SHALL MULCH ALL SHRUB ANNUAL AND PERENNIAL BEDS WITH 4" AND UTILITY EASEMENT ' f ( ,a,. / * DOUBLE � ft. f, .gg'. SHREDDED HARDWOOD MULCH. w. 1 , •, . 5. AREAS NOT INDICATED TO RECEIVE SOD OR MULCH SHALL BE SEEDED BY � ALL DISTURBED THE CONTRACTOR. Community Service PROPOSED SIGNAGE 1 { ,�� 1 � y 1 � "`�`` 1 \ �\ + �' �+� + � �v> `� �°° \ EASEMENT AREA �„ " 6. CONTRACTOR SHALL REMOVE ALL HARD LUMPS OF CLAY, STONES OVER 1" IN DIAMETER, El (CONTROL) � �\ C4 Q �� �' + + +* + * * �, �1`� °tea, AND ALL CONSTRUCTION DEBRIS INCLUDING GRAVEL, ROOTS, LIMBS AND OTHER DELETERIOUS Learning i n Center #V �. g \\ = • ' * + + * + + + n MATTER WHICH WOULD BE HARMFUL, OR PREVENT PROPER ESTABLISHMENT AND OR PLANT SCHEDULE (INCLUDES WETLAND SHRUBS) / x + * * + + + * + MAINTENANCE OF LAWN AND PLANTING AREAS. gy + +* + + + y a Brunswick + 7. IN PLANTING BED AREAS WHERE CONSTRUCTION GRAVEL IS EMBEDDED IN THE SOIL TREES TY BOTANICAL NAME COMMON NAME CONT SIZE SPAC 1 MYCS � ^ � =K"`-� + + + ,«, ,, . LACA 4 LAGERSTROEMIA INDICA 'CATAWBA' CATAWBA TREE CRAPE MYRTLE MULTI-TRUNK B&B 2" CAL. A.I. 4 DARA CONTRACTOR SHALL REMOVE CONTAMINATED SOIL TO A DEPTH OF 8" AND FILL WITH CLEAN \� + + + + + TOPSOIL. CONTRACTOR SHALL IMPORT TOPSOIL AT NO CHARGE TO OWNER IF REQUIRED TO East Carolina University MASW 20 MAGNOLIA VIRGINIANA SWEET BAY B&B 6'-10' HT. A.I. + + ». FILL THESE EXCAVATIONS. 6 CLEH School of Dental Medicine QUNU 3 QUERCUS NUTTALLII NUTTALL OAK B&B 2.5"-3" CAL. A.I. f - + 8. CONTRACTOR SHALL RESEED RESOD LAWN AREAS DAMAGED DUE TO PLANT MATERIAL 2 CALA « r� + * +�1 � �` INSTALLATION. / QUEP 9 QUERCUS PHELLOS WILLOW OAK B&B 2.5"-3" A.I. 12 (TVA \ b ' *.; + + * + +� r Brunswick Count NC 9. CONTRACTOR SHALL COORDINATE ALL PLANTING IN THE RIGHT-OF-WAY WITH THE NORTH y ULMA 8 ULMUS PARVIFOLIA 'ALLEE' ALLEE LACEBARK ELM B&B 2"-2.5" CAL. A.I. 15 (TVA +V + ++ * :q CAROLINA DEPARTMENT OF TRANSPORTATION OR LOCAL TRANSPORTATION DEPARTMENT. SHRUBS 2 BOTANICAL NAME COMMON NAME CONT S� SPAC 6 MYCS a + ++ ++ + ++ + ++ + '" 10. ALL STRAPPING AND TOP 2 3 OF WIRE BASKET SHALL BE CUT AWAY AND REMOVED BY CALA 18 CALLICARPA AMERICANA AMERICAN BEAUTYBERRY CONT 24"-30" HT/SPR 4' O.C. 26 CLEH + + * + + THE CONTRACTOR FROM ROOT BALL PRIOR TO BACKFILLING PLANTING PIT. CONTRACTOR 1 CHVI SHALL REMOVE TOP 1/3 OF THE BURLAP FROM ROOT BALL. CAMG 3 CAMELLIA SASANQUA 'SHISH(-GASH IRA' CAMELLIA CONT 40"-48" HT. 5' O.C. , + + + 15 DARA . ,. �,>. SYM COMMON NAME BOTANICAL NAME SIZE ROOT SPACG NOTES 9 CALA + + "g 11. FOR NEW TREE PLANTING AREAS, CONTRACTOR SHALL REMOVE ALL PAVEMENT, GRAVEL CHVI 5 CHIONANTHUS VIRGINICUS WHITE FRINGETREE 5 GAL. 40'-48" HT. A.I. # t� ' SUB-BASE AND CONSTRUCTION DEBRIS; REMOVE COMPACTED SOIL AND ADD 24" NEW DATE- 07/02/2014 t` TOPSOIL, OR AMEND THE TOP 24" OF EXISTING SOIL TO MEET SPECIFIED TOPSOIL P CLEH 42 CLETHRA ALNIFOLIA 'HUMMINGBIRD' SUMMERSWEET CONT 18"-24" HT, 4' O.C. HERBACEOUS WETLAND PLANTS _ SHALLOW WATER OFF-SITE DITCH TO BE STAB( EC / CANTING SCALE: A$ indicated a NORTH AMERICAN GREEN SC 250 ERO$I MIX STANDARDS FOR TREES. DARA 30 DANAE RACEMOSA POET'S LAUREL CONT 24"-30" HT. 4' O.C. 90 SOFT RUSH JUNCUS EFFUSUS 4" CONT. 18-24"OC CONTROL MATTING, 62,000 SF OF SEED, WI I -' .g � � EYP PROJECT NO.: 6013031.01 w= � 12. LARGE MATURING TREES SHALL BE A MINIMUM 25 TO 30 FEET FROM THE OVERHEAD VAR. PYLAEI LIMITS OF OFFSITE DITCH DISTU BAN :,�-•.>�•,�a „��• y` k ! DISTRIBUTION OR TRANSMISSION LINES. IF TREES CONFLICT WITH POWER LINES OR SIGNS, ILEC 28 ILEX CORNUTA 'CARISSA' CARISSA HOLLY CONT 15"-18" HT. 3' O.C. 90 DUCK POTATO SAGITTARIA LATIFOLIA 4" CONT. 18-24"OC N CONTRACTOR SHALL CONTACT ZONING OFFICIAL TO RESOLVE BEFORE PLANTING. ILEP 55 ILEX CORNUTA 'NEEDLEPOINT' NEDDLEPOINT HOLL f CONT 24"-30" HT. A.I. INSET A - WETLAND PLANTING PLAN SCALE 1'-307 13. MINIMUM TREE SIZE AT PLANTING SHALL BE TWO-INCH (2") CALIPER AT 4.5 FEET HIGH, 90 PICKERELWEED PONTEDERIA CORDATA 4" B&B 18-24"OC PER BRUNSWICK COUNTY LANDSCAPE GUIDELINES. ALL MULTI-STEM PLANTS SHALL BE ILNP 39 ILEX CORNUTA 'NEEDLEPOINT' NEDDLEPOINT HOLLY CONT 40"-48" HT. A.I. TREE FORM, MAXIMUM THREE TO FIVE TRUNKS, AND A MINIMUM EIGHT FEET TALL. ALL ILES 19 ILEX CRENATA 'STEEDS' STEEDS JAPANESE HOLLY CONT 30"-36" HT. 3' O.C. 90 SOFT STEM SCHOENOPLECTUS 4" CONT. 18-24"OC SYM COMMON NAME BOTANICAL NAME SIZE ROOT SPAC'G NOTES SHRUBS SHOULD HAVE A MINIMUM MATURE HEIGHT OF 24". DESIGNED BY: AWK BULRUSH TABERNAEMONTANI # 14. INSTALLER SHALL AGREE TO REPAIR OR REPLACE PLANTINGS THAT FAIL IN MATERIALS, DRAWN BY- HERBACEOUS 22 ILEX GLABRA 'SHAMROCK' INKBERRY CONT 30"-36" HT. 5' O.C. gp ARROW ARUM PELTANDRA VIRGINICA 4" CONT. 18-24"OC HERBACEOUS WETLAND PLANTS - SHALLOW LAND WORKMANSHIP, OR GROWTH WITHIN SPECIFIED WARRANTY PERIOD. SEE PLANTING SPECIFICATIONS FOR WARRANTY PERIOD AND FAILURE DESCRIPTIONS. CHECKED BY: RTF (TVA 63 (TEA VIRGINICA VIRGINIA WILLOW CONT 30"-36" HT. 4' O.C. g0 SWEETFLAG ACORUS SUBCORDATUM 4" CONT. 18-24"OC 160 GREAT BLUE LOBELIA SIPHIUTICA 4" CONT. 18" OC LOCR 9 LOROPETALUM CHINENSIS RUBRUM 'RUBY' RUBY FRINGE FLOWER CONT 18"-24" HT. 5' O.C. LOBELIA 15. FOR SEEDED AREAS, AN ACCEPTABLE LAWN AT THE END OF THE MAINTENANCE PERIOD SHALL CONSIST OF A HEALTHY, UNIFORM, CLOSE STAND OF GRASS, FREE OF WEEDS AND SURFACE 90 BLUE FLAG IRIS IRIS VIRGINICA 4" CONT. 18-24"OC 160 NARROW SACCHARUM BALDWINII 4" CONT, 18" OC IRREGULARITIES, WITH TOTAL GRASS COVERAGE EXCEEDING 90 PERCENT OVER ANY 10 SQ. FT. AND MYCS 13 MYRICA CERIFERA WAX MYRTLE 5 GAL. 30"-36" HT. 6' O.C. PLUMEGRASS BARE SPOTS NOT EXCEEDING 5 BY 5 INCHES, WITH AT LEAST 85% OF THE TOTAL GRASS COVERAGE SPAW 15 SPIRAEA X BUMALDA 'ANTHONY WATERER' ANTHONY WATERER SPIRAEA CONT 12"-15" HT. 3' O.C. 90 WOOLGRASS SCIRPUS CYPERINUS 4" B&B 18-24"CC 160 SPOTTED EUPATORIADELPHUS 4" B&B 18" OC CONSISTING OF BERMUDA. REFER TO SPECIFICATIONS_ TRUMPETWEED MACULATUS VINU 8 VIBURNUM NUDUM POSSUMHAW CONT 30"-36" HT. 6' O.C. 90 PRIMROSE WILLOW LUDWIGIA SPP. 4" CONT. 18-24"OC 160 QUILL SEDGE CAREX TENERA 4" CONT. 18" OC VTSB 12 VIBURNUM TINUS 'SPRING BOUQUET' SPRING BOUQUET LAURESTINU CONT 18"-24" HT. 4' Q.G. PLANTING 90 WATER PLANTAIN ALISMA SUBCORDATUM 4" CONT. 18-24"OC 160 SEASHORE MALLOW KOSTELETZKYA VIRGINICA 4" CONT. 18" OC GROUND COVERS � BOTANICAL NAME COMMON NAME CONT SIZE SPAC N C601 SOD 9,870 SF BERMUDA 'TIFTON 419' BERMUDA SOD SOD PROVIDE EVEN DISTRIBUTION OF THE ABOVE PLANTS IN GROUPINGS TO PROVIDE ADEQUATE COVER OF THE NOTED PROVIDE EVEN DISTRIBUTION OF THE ABOVE PLANTS IN GROUPINGS TO PROVIDE ADEQUATE COVER OF THE NOTED SCALE: 1" = 30' PLAN SEED 62,483 SF HYBRID BERMUDA SEED HYBRID BERMUDA SEED SHALLOW WATER AREA NOTED ON THE PLAN. SHALLOW LAND AREA NOTED ON THE PLAN. 0 15 30 60 EYP Architecture & Engineering, PC 811 West Hargett Street YP / FACE OF CURB C EDGE OF PAVE Raleigh, N 27603 2 PAVEMENT Raleigh, 919 833 8818 1 Lo Fax: 919 833 6898 2/3Do VAN V MUTCD R7-8P 12"x6" eypae.com 0 00� SLOPE -> z A ONLY REQ'D 0 VAN CONDITION 1: PEDESTRIAN PATH 0"+ 0"+ C"+ 10' WIDTH VARIES SEE STAKING PLAN 10' ACCESSIBLE ACCESSIBLE SPACES i� DOES NOT PASS io "+ 0"+ 0 + 6"+ S. CONSULTANT FILTER FABRIC IS TO BE USED O / UNDER OR AROUND to FLUSH CJRB EDGE 0 PAVEMENT PROFILE 0 SIGN SECTION A-A N 1__� 6°-0" WIDTH VARIES 6'-0" 0"+ 6"+ 6"+ 0"+ 1/2" La Z CONDITION 2: PEDESTRIAN PATH RESERVED SIDEWALK Structural ngiEngn eying, RADIUS s" 1'-0" Stewart Engineering, Inc. 3" RADIUS 421 Fayetteville St., Suite 400 GOES BY, UNDER, FACE OF CURB RADIUS 2 SIDE ANGLE FOR LOW TAILWATER 1 5 SI AROUNDPARKING 0"+ 6„+ 6��+' O"+ cvRaleigh, NC 27601 111::5 SIDE ANGLE FOR HIGH TAILWATER SIGN o MUTCD R7-8 TOP OF JURB FLUSH CURB TOP OF CD + 6 + 6 + 6' + Tel: 919 380 8750 0 Fax: 919 380 8752 12"x26" CURB FLUSH CURB 1'-6" F STANDARD 1'-6" CURB AND GUTTER Civil Engineering/ Landscape Architecture: oµwB SLOP cuR6 Cole Jenest & Stone, p a � r EDGE OF 0"T b �' ✓4 °�v 1„ PER FT. PAVEMENT 0„+ e, a a ' ' ' ++ _ MAX MUM 119 East Hargett Street, Suite 300 NOTES: r ° N CURB TRANSITION AT ACCESIBLE RAMP N.T.S. 9B Raleigh, NC 27601 1. SEE TABLE BELOW FOR RIPRAP SIZE, , II M z z CONCRETE SIDEWALK LENGTH, WIDTH AND DEPTH OF APRON. 3 II O O PENALTY CONTINUOUS CONC. PAVING Tel 919 645 5964 F- �_ CURB ACROSS Fax: 919 719 1819 � Jy 3 $250 BACK OF CURB CONTRACTION JOINT 2. RIPRAP SHOULD EXTEND UP BOTH SIDES OF THE APRON AND AROUND THE END O TRANSITION OF THE PIPE OR CULVERT AT THE DISCHARGE OUTLET AT A MAXIMUM SLOPE OF O O CULVERT HEHEIGHT NOT LESS THAN TWO THIRDS THE PIPE DIAMETER OR U U TOP OF CURB NOTES: Plumbing Mechanical Electical & Fire Protection: 3. THERE SHALL BE NO OVERFLOW FROM THE END OF THE APRON TO THE EYP, Inc SURFACE OF THE RECEIVING CHANNEL. THE AREA TO BE PAVED OR RIPRAPPED 2'-6" FLUSH CURB 1. CONTRACTION JOINTS SHALL BE SPACED AT 10-FOOT INTERVALS. SHALL BE UNDERCUT SO THAT THE INVERT OF THE APRON SHALL BE AT THE 1'-6" CURB l O' 10' 420-1-A The Parkway SAME GRADE (FLUSH) WITH THE SURFACE OF THE RECEIVING CHANNEL THE 't 0 CURB & GUTTER & PAVEMENT 2. CONTRACTION JOINTS MAY BE INSTALLED BY THE USE OF TEMPLATES OR FORMED APRON SHALL HAVE A CUTOFF OR TOE WALL AT THE DOWNSTREAM END. FINISH GRADE GUTTER BY OTHER METHODS. WHERE SUCH JOINTS ARE NOT FORMED BY TEMPLATES, Greer, SC 29650 4. THE WIDTH OF THE END OF THE APRON SHALL BE EQUAL TO THE BOTTOM LIP of GUTTER/EDGE CF PAVEMENT A MINIMUM DEPTH OF 1 1/2" SHALL BE OBTAINED. Tel: 864 334 0997 WIDTH OF THE RECEIVING CHANNEL. MAXIMUM TAPER TO RECEIVING CHANNEL 5:1 5. ALL SUBGRADE FOR STRUCTURE TO BE COMPACTED TO 95% OR GREATER. 3. ALL EXPANSION JOINTS SHALL BE SPACED AT 90-FOOT INTERVALS, AND Fax: ADJACENT TO ALL RIGID OBJECTS. JOINTS SHALL MATCH LOCATIONS WITH JOINTS 6. THE PLACING OF FILL, EITHER LOOSE OR COMPACTED IN THE RECEIVING ' SLOPE ASPHALT AND EDGE OF PAVEMENT / ij ��/��; IN ABUTTING SIDEWALK. CHANNEL SHALL NOT BE ALLOWED. GUTTER AT 0.6" PER 4. ALL CONSTRUCTION JOINTS SHALL BE FILLED WITH JOINT SEALER. ��� FOOT ////////III S", CAN 7. NO BENDS OR CURVES IN THE HORIZONTAL ALIGNMENT OF THE APRON WILL ` O BE PERMITTED. �// �` �� 0 5. CONCRETE COMPRESSIVE STRENGTH SHALL BE 3500 P.S.I. IN 28 DAYS. Q� & 5'-0" 5'-0" 6. CURB SHALL BE DEPRESSED AT INTERSECTIONS TO PROVIDE FOR FUTURE ����`�;�5.• STD _ �OQ ��FESS/0** ��� l��y� ACCESSIBLE RAMPS. o�`PQRgr'•.� 9 �� STRUCTURE PIPE DIA. Q10 UPST. W La DWSTR. W d50 dMAX Depth NCDOT CLASS '" u = Q r P ,i ���� i� PLAN VIEW w SEAL :�" � - FES-1 15" 1s.31 cFs 4.0' 10' 14' 4" s" 1z" A NOTE: 7. TOP 12" OF SUBGRADE BENEATH THE CURB AND GUTTER SHALL BE COMPACTED %R _J C-1361 C-�� - FES-2 24" 25.7 cFs 6.0' to' 16' 4" s" 12' A TO 100% STANDARD PROCTOR DENSITY. :yo� CARo�2Q:`� `� ~ 5 ` 1. TRANSITION TO BE ALONG BACK OF CURB. �� "' ����` '�� •.�tir;I N�F'� •.��� ••S O N.T.S. ���iiaai�Ut ODD..F• `` %% GRAVEL AND RIP RAP APRON N.T.S. 15 ADA PARKING SIGN DETAIL N.T.S. 12 CURB TRANSITION FROM 2 6 TO 1 6>, N.T.S. 9A TRANSITION TO FLUSH CURB AT DROPOFF 6 CONCRETE CURB AND GUTTER N.T.S. 3 ,` ► 10/06/14 NOTES: LOW MODULUS SILICONE 1. BIKE RACKS SHALL BE 2-7 8" DIAMETER INVERTED 'U' NON 25% LARGER BACKER JOINT SEALANT 6" SCH 40 GALVANIZED STEEL / ROD 25% LARGER THAN LOW MODULUS SILICONE 6" "BIKELOOP-ING" AS MANUFACTURED BY WEBCOAT, INC., JOINT SEALER JOINT WIDTH CONCRETE PAVING JOINT SEALANT PIPE FILLED W/ CONCRETE AND INSTALLED PER MANUFACTURER'S SPECIFICATIONS. CONCRETE PAVING ROUNDED CONCRETE TOP II 1/8" RADIUS INSTALL JOINT AND FILLER; 2. ALL RACKS TO HAVE BLACK MATTE FINISH. 1/2" JOINT AND FILLER; 1/8" TO 1/4" INSTALL FULL DEPTH OF INSTALL FULL DEPTH OF 3. ALL DIMENSIONS SHOWN ARE MINIMUM. CONCRETE CONCRETE WALL OR 6'-0 2-7/8"" DIA. SCH. 40 4'-0" N RIGID OBJECT `D w GALVANIZED STEEL PIPE Q JOINT rh w FI LLER CD 11' 9" R, �4" 1/2" y a s d 1 REVIEW COMMENTS 06111114 ,kk ROUND OR DIAMOND PLATE FINISH GRADE o TYP. PREFORMED JOINT FILLER DOWEL, SEE TABLE s ) rr 2 BID DOCUMENTS 07/02/14 GROOVE JOINT EXPANSION JOINT m z 4" - 3500 PSI SLAB DOWEL DOWEL / 3 ADDENDUM 1 07/25/14 CONC. SLAB t/2" EXPANSION JOINT (SEAL TO MAKE WATERTIGHT) THICKNESS DIMENSIONS (IN) CENTER-TO-CENTER NON-ABSORBANT BACKER O CORE DRILL 1" ago IN) SPACING (IN) / .•,�y 4s x, J LARGER THAN PROPOSED CURB AND GUTTER ( ROD 25% LARGER THAN 4 REVIEW COMMENTS 07/31/14 /, Q PIPE DIA. ROUND DIAMOND ROUND DIAMOND JOINT WIDTH _N MIN. 1141 PER FT. X 14 Y4 X 4-j X 4-1 12 18 PREFORMED JOINT FILLER 5 NCDENR EROSION CONTROL 10106114 - -J X /8 X 4- X 4- 10 7 - 8 1 16 3 12 18 SIDE VIEW 26 " 12 20 6 NCDENR STORMWATER 11114114 4 COMPACTED AGGREGATE BASE 1-} X 18 �'a X 4-� X 4-� TYPICAL EXPANSION JOINT « 112"I. 'I -'I` PROPOSED 4" CONCRETE TYPICAL CONSTRUCTION JOINT � (3000 PSI) EDGE OF SLAB CONCRETE GENERAL NOTES NOTES: io w 2'-9„ Q 1. A GROOVE JOINT 1" DEEP WITH 1/8" RADII SHALL BE REQUIRED LOW MODULUS SILICONE 1, THICKNESS OF SEALENT TO BE Yz OF JOINT WIDTH. w IN THE CONCRETE SIDEWALK AT 5' INTERVALS OR AS INDICATED NON-ABSORBANT BACKER JOINT SEALANT m ON PLANS. ONE 1/2" EXPANSION JOINT WILL BE REQUIRED AT 45' ROD 25% LARGER THAN ---A 12" O Q 2, JOINT FILLER STRIPS TO BE ASTM 1751 ASPHALT-SATURATED CELLULOSIC FIBER. Z J INTERVALS NOT TO EXCEED 50' AND MATCHING EXPANSION/CONSTRUCTION JOINT WIDTH CONCRETE PAVING p cn JOINT IN ADJACENT CURB. A SEALED 1/2" EXPANSION JOINT WILL BE REQUIRED WHERE THE SIDEWALK JOINS ANY RIGID STRUCTURE. 3, CONCRETE TO BE CURED 28 DAYS, DRY, AND JOINT BLOWN CLEAN OF ALL � � � o DEBRIS WITH HIGH-PRESSURE AIR BEFORE INSTALLATION OF JOINT SEALANT # Revision Date m 2. CONCRETE COMPRESSIVE STRENGTH SHALL BE 3500 PSI, IN 28 DAYS. o i w MATERIAL. ar 2'-9" TYP. O X Y4„ MIN. / 3/4" MAX. 1 „ OBJECTS, X COLD JOINTS. NOTES: w 4• PROVIDE EXPANSION JOINTS AT INTERSECTIONS OF ALL STRUCTURES, FIXED SCO I D#. 07-07054-02J Q � � 4. SEE PLAN FOR SIDEWALK WIDTH. 1. SEE PLAN FOR NUMBER OF POSTS TO BE USED. < 6'_0" n 5. SAW CUT JOINTS SHALL NOT EXCEED 15' X 15' GRID. THE GRID PATTERN 2. THE STEEL PIPE ABOVE GROUND SHALL BE PAINTED A SHALL BE UNIFORM THROUGHOUT THE PROPOSED PAVEMENT AREA. REFER TO MINIMUM OF TWO FIELD COATS OF ZINC CHROMATE PRIMER. WALL OR BUILDING FACE SITE PLAN FOR PROPOSED JOINT PATTERN. PLAN VIEW TYPICAL SAW CUT CONTROL JOINT BOLLARD DETAIL N.T.S. 14 INVERTED AU* RACK FOR BICYCLE PARKING N.T.S. 11 CONCRETE SIDEWALK N.T.S. 8 TYPICAL EXTERIOR CONCRETE JOINT DETAILS N.T.S. S-O" MIN. END OF ROADWAY MARKER CONTINUOUS X FLUSH CURB BACK OF WALK CONC. SIDEWALK BITUMINOUS CONCRETE (ER-1, 24"x24", RED) PASSAGE PER DETAIL 8/C701 SURFACE COURSE-TYPE SF-9.5A m TACK COAT Community S e ry i c e r 5' m C - �- JOINT;nz 0) ACK OF CURB N BITUMINOUS CONCRETE ER-1 1 EXP. JOINT A- A INTERMEDIATE COURSE-TYPE S-9.5A Learning Center #8 w X io i `V \� FLUSH CURB LIGHT BROOM FINISH AGGREGATE BASE COURSE PAVEMENT 6'-0" 4'-0" 6'-0" FACE OF CURB /��� \��\ FACE OF CURB o0 (COMPACTED 100% MODIFIED Brunswick PLAN - PARALLEL RAMP WWF 6X6 W 1.4 X W 1.4 �, PROCTOR DENSITY) m COMPACTED SUBGRADE • 5' TRANSITION FROM 12:1 SLOPE 12:1 SLOPE CONCRETE 4000 PSI 4' WALK TO 5' WALK. , (TOP 12"0% COMPACTED East Carolina University TO 100) STD PROCTOR STREET BARRICADE 6' 6 ° ALL WALKS MUST BE - - MATCH WIDTH OF - AGGREGATE BASE COURSE COMPACTED / DENSITY School of Dental Medicine WALK PER PLAN , 3' END ROAD FILL RAMP. ELEVATION PLAN COMPACTED SUBGRADE COMPACT TOP 12" To 100% Z 12:1� SLOPE1 12:1�SLOPE 1 j /, STD. PROCTOR DENSITY Brunswick County NC SIGN LOCATION DETAIL SIDEWALK 3'-0" MIN. BACK OF WALK t t \ EXP. JOINT CONTINUOUS T PASSAGE FLUSH ELEVATION DEPRESS CJRB AT WALK �X CURB BACK OF CURB HEAVY DUTY BITUMINOUS CONCRETE N.T.S. 1B CROSS -(-s. FACE OF CURB PERPENDICULAR RAMP SECTION S ml C B` C `00 Z WITH CONTINUOUS WALK PERPENDICULAR TO CURB DATE: OF POST 0710212014 0 (14 GAUGE) A - - A X XP. JOINT GENERAL NOTES NOTES BITUMINOUS CONCRETE SCALE: As indicated SURFACE COURSE-TYPE SF-9.5A 0" 1.AT PUBLIC STREET INTERSECTIONS, RAMP PLACEMENT AND CONSTRUCT ON ?. ALL CONCRETE TO BE 4000 PSI. TACK COAT EYP PROJECT NO.: 6013031.01 o x DIMIENSI O" 4'-0" 6 MENT SHALL CONFORM TO NCDOT STANDARDS. DUAL RAMPS SHALL BE REQUIRED y o a DN5 AT EDGE OF PAS AT LOCATIONS SHOWN ON PLAN. 2. REFER TO DETAIL 2/C701 FOR o III r m BITUMINOUS CONCRETE POST o _"""" PLAN - DIAGONAL RAMP 2. ALL CONCRETE TO BE 3500 P.S.I. COMPRESSIVE STRENGTH. TYPICAL JOINT CONSTRUCTION. INTERMEDIATE COURSE-TYPE 5-9.5A o _ f o o O Z 3. RAMP SURFACE SHALL HAVE COURSE FINISH CONTRASTING WITH ADJACENT ,- ° � ADJACENT WALK ® 1/4" PER FOOT WALKWAY. - f AGGREGATE BASE COURSE o w N 3-3/4" BACK OF CURB io (COMPACTED 100% MODIFIED ° I j 3-3/4" 1 4" PER FOOT 12 FACE OF CURB 4. GUTTER FLOW LINE SHALL BE MAINTAINED THROUGH THE RAMP AREA. PROCTOR DENSITY) DESIGNED BY: AWK o �1 o a- g ' .. �• 5.THE SURFACE OF THE RAMP SHALL BE FLUSH WITH THE GUTTER FLOW LINE. COMPACTED SUBGRADE (TOP 12" COMPACTED DRAWN BY: ° TO 100% STD PROCTOR 12:1 3'-0" 2•-0" -� SLOPE "A" ` ,� ` ' / r` DENSITY) CHECKED BY: RTF BASE o SECTION X-X SLOPE "B" 1/4"/FT (SLEEVE) o PARALLEL RAMP SLOPE "C" 1/2"/FT WITH CONTINUOUS WALK PARALLEL To CURB END OF ROAD MARKERS N.T.S. C13) ACCESSIBLE RAMP N.T.S. 7 CONCRETE PAVING AT DUMPSTER PAD N.T.S. 4 STANDARD DUTY BITUMINOUS CONCRETE N.T.S. 1A SITE DETAILS C701 EYP Architecture & Engineering, PC 811 West Hargett Street YP / REDUCED PRESSURE PRINCIPLE ASSEMBLY Raleigh, NC 27603 EQUAL SPACING- Tel: 919 833 8818 BOTH DIRECTIONS Fax: 919 833 6898 SHUT-OFF VALVE#1 SHUT-OFF VALVE#2 eypae.Com REDUCED PRESSURE CONSULTANTS- 1/4 TURN FULL PORT PRINCIPLE ASSEMBLY 1/4 TURN FULL PORT BRONZE BALL SHUT-OFF BRONZE BALL SHUT-OFF Structural Engineering: ( CHECK VALVE#1 VALVE #1 CHECK VALVE #2 VALVE #2 Stewart Engineering, Inc. TEST COCK#1 ... CHECK VALVE#2 a CHECK VALVE #1 6 _._ ,,,, ;�� �._._.: 421 Fayetteville t., Suite 4 R Z OUTLET _ STRAINER Raleigh, NC 27601 RESTRAINED JOINT /yy , J OPTIONAL Tel: 919 380 875 ELECTRICAL OUTLE Fax: 919 380 8752 REMOVABLE INSULATED i ` �� SUPPORTS MEETING ASSE CIVII Engineering/Ineerin 1 Landscape Architecture: .� �� REMOVABLE INSULATED �7 E ) � � .„, ENCLOSURE ME g g p,: ,, . 1060 SPECIFICATIONS.AS SE MEETING AaSE Cole Jenest & Stone, pa CONCRETE SLAB TYP. INSULATED 1060 SPECIFICATIONS. ' ... 'yA ' 10 ENCLOSURE TO INCLUDE -1 _.. I, ) FIBERGLASS ENCLOSURE TO INCLUDE r{ DRAIN PORT(S). SEE DETAIL TEST COCK #1 LOWEST 119 East Hargett Street, Suite 300 FLOW-� ENCLOSURE; DRAIN PORT(S).SEE DETAIL h DUCTILE IRON PIPE 15/C702 POINT Raleigh, NC 27601 NG ENCLOSURE WALL SIZE AS 15/C702 I;I � ;: s, FOR MIN.OF 5'ON EACH z a OALRELIEF ORP1"KM MIN. GALOVANIZED SPPER TEEL Tel: 919 645 5964 REQUIRED TO ~, ( END OF ASSEMBLY. OUTLET PIPE FOR MIN. OF 5' ON FIT BACKFLOW SUPPORTS- I RELIEF VALVE N ` Fax: 919 719 1819 ANCHOR 12"MIN. o EACH END OF ASSEMBLY. i PREVENTION j 30°MAX. OUTLET SLOPE AWAY 4' �� CONC. SLAB DEVICE SLOPE GROUND a n a n FROM COVER, Plumbing Mechanical Electical & Fire Protection: AWAY FROM 9� a a a . COVER 1 , _.._ II TYP. EYP, Inc I e I I I I,I I -- he Parkway � �° 420 I A T 6" VLOWEST POINT OR I' Greer SC 29650 RELIEF VALVE OUTLET ? ( .7 SLEEVE REQUIRED--""' SUPPORT AND PAD NOTES: (TYP.) � p, AS REQUIRED Tel 864 334 0997 SUPPORT, PAD AND Fax: 1. PROVIDE 120V, GROUND FAULT PROTECTED, CIRCUIT TO BFP FOR UNIT HEATERS (REFER TO CONCRETE FOOTINGS ELECTRICAL PLAN). MOUNT OUTLET 6• ABOVE DISCHARGE POINT OF RPZ UNITS. (I -- 2. LEVEL SURFACE AROUND BFP 6" IN EACH DIRECTION BEYOND ENCLOSURE OUTSIDE DIMENSIONS. 3. POUR FULL CONCRETE PAD 4" THICK AROUND BFP, MIN. 6" IN EACH DIRECTION BEYOND RESTRAINED JOINT MIN.4"THICK ''�� �� `� ��`N C 4R�C���/�� ENCLOSURE INSIDE DIMENSIONS. CONCRETE PAD `,� Cj� & s�'� SS��'••• REQUIRED NOTES: �`` ��''POR ZO'��0`r /�'1'•% 4. INSTALL ENCLOSURE PER MANUFACTURE'S SPECIFICATIONS. NOTES: `` ? �9L q� \ y •;� 5. ENCLOSURE SHALL INCLUDE DRAIN PORTS FOR DISCHARGE WATER. 1. ENCLOSURE SHALL BE PROVIDED WITH UNIT HEATERS WHICH ARE UL-LISTED FOR INSTALLATION IN WET LOCATIONS. W : SEAL ENCLOSURE SHALL BE PROVIDED WITH UNIT HEATERS WHICH ARE UL-LISTED FOR INSTALLTION IN WET LOCATIONS J ; C-1361 \ 6. FOR FIRE LINE INSTALLATIONS, PROVIDE TAMPER SNATCHES AND TEMPERATURE-SENSING SWITCH 2. FOR FIRE LINE INSTALLATIONS, PROVIDE TAMPER SWITCHES CONNECTED TO ALARM CONTROL PANEL SEE SHEET E400. p 10 C-103 2� � � 5 CONNECTED TO ALARM CONTROL PANEL (SEE ELECTRICAL PLAN). 3. FOR FIRE LINE INSTALLATIONS, PROVIDE TEMPERATURE-SENSING SWITCH CONNECTED TO ALARM CONTROL PANEL. SEE SHEET E400. v .PryCARo�; �� TYPICAL BFP ENCLOSURE INSTALLATION N.T.S. 15 6" REDUCED PRESSURE PRINCIPLE ASSEMBLY N.T.S. 9 1.5" AND 2.5" REDUCED PRESSURE PRINCIPLE ASSEMBLY N.T.S. 3 ""'�"'''' °0p,,,;; 14 /06/ NOTES 1. INLET MAINTENANCE SHALL BE DOCUMENTED IN PROJECT LOG BOOK. 2. FILTER TYPES SHALL BE APPROVED BY THE CITY INSPECTOR PRIOR BUILDING TO INSTALLATION. FACE CLEANOUT COVER ASSEMBLY, 4" THK., 3000 PSI 3. FILTER BAGS MAY BE REMOVED WHEN SITE IS STABILIZED AT CAST IRON FRAME WITH BOLTED CONC. PAD TO BE FORMED THE DIRECTION OF THE ENGINEER. 3"X4" OR THREADED, SOLID LID SET AROUND CLEANOUT FRAME. 4. FILTER BAGS SHALL BE REMOVED PRIOR TO STREET ACCEPTANCE. DOWNSPOUT FLUSH IN A CONCRETE BORDER. 4„ 5. FILTER BAGS SHALL BE CLEANED OR REPLACED ON A REGULAR DEWATERING OUTLET BASIS (NOT BE MORE THAN HALF FULL AT ANY TIME). SEAL AROUND 6. FILTER BAGS SHALL NOT BE ALLOWED IN EXISTING CITY OR NCDOT JOINT DIRT BAG FILTER ROADS. CAST-IRON PUMP HOOD DOWNSPOUT -�- � 0 1 REVIEW COMMENTS 06/11/14 F�OIy , EXCAVATE TO GRATE ADAPTER ❑❑' .o❑ 2 BID DO CUMENTS 07102114 INTAKE PIPE TO PUMP CREATE BASIN I ' 0 1" REBAR FOR GRATE CLEANOUT -- BAG REMOVAL EXPANSION 3 ADDENDUM 1 07/25/14 FROM INLET CLEANOUT RISER WITH 55 GALLON DRUM ' RESTRAINT 4 REVIEW COMMENTS 07131114 FLOW THREADED PLUG DEFLECTOR 1-3/8" ". `�O l % /j��' FINISHED GRADE /` / � `< INSTALL SILT FENCE / r \ SILT FENCE AROUND INSIDE of � 5 NCDENR EROSION CONTROL 10/06/14 AROUND DRUM ��� DRUM ZTEMPORARY 6 NCDENR STORMWATER 11/14/14 ;� WATER LEVEL SEDIMENT PLAN r / / 1' STORAGE 7 y TYP. 1 FILTER BAG I W o 0 0 ' Z 2 "�`� DUMP LOOPS ° ° WYE FITTING *r ° -- i / LATERAL DRAIN LINE 90' BEND SIZE AND SLOPE PER PLAN CATCH BASIN---' # Revision Date 3/4" HOLES FLOW OUTLET \ #5 WASHED STONE `HEADER PIPE �4" PVC BELOW DRUM SIZE PER PLAN SCO I D#: 07-07054-02J CONCRETE OR CONCRETE BLOCK INSTALLATION SECTION DELUXE FILTER SUMP TO PUMP AND DIRT BAG FILTER N.T.S. 11 CATCH BASIN INLET PROTECTION N.T.S. 8 ROOF DRAIN DETAIL W/ CLEANOUT N.T.S. 5 TYPICAL CLEANOUT N.T.S. 2 '' . 2'-0" MIN. Z 10' MAX. SPILLWAY SLOPE TRENCH SIDES SLOPE TRENCH SIDES 50' MIN. TOP STRAND MIN. -L� #12-1/2 GUAGE Community Service CREST PER OSHA REQUIREMENTS PE HA U PUBLIC STREET z #10 GUAGE i STAY WIRES MIN. ■ # 5 WASHED STONE EXISTING �' \ IIII III RIP RAPS IIII_ IIII IIII IIII IIII IIII GROUND ..__..... Ij I�i „1I, � 9 , I� try I 13 �U r ; W ■ "Al", _ - ....._ r Learning Center #8 _ a e f SE FILLECL SOIL STABILIZATION FABRIC �� --,- �+ r STEEL T POSTS (MIN 5' LENGTH) 2'-0" IN GROUND FLOW 12„ 12„ UNDER #5 WASHED STONE Z ■ - Brunswick _ _ un 50' MIN. SELECT INITIAL - =---- _._ y,. ,. � BACKFILL _ / !/ / �' /-; i� 19 GUAGE HARDWARE � y. �iCLO d " ' ' y w East Carolina University y,. ,..,; '°j�`=,� • � � � - �� O O WITH } INCH MESH OPENING ,��. k '„ e "� � BOTTOM STRAND MIN. #10 GUAGE School of Dental Medicine __.__ SECURED TO STEEL POSTS Z (n i s MIN 4" HAUNCHING � � ' SECTION A-A BEDDING _ _ BOTOM' AlLLO 2NFLAP of U _ BEDDING REQUIRED IF _ NAR�E�MESH UNDER THE 07 Brunswick County N C W (SPILLWAY) IIII-IIII IIII-IIII TRENCHING I I -IIII-IIII-IIII ' i .. IN 2/3 STREAM WIDTH - - IN ROCK IIII- IIII- ,. .,.±,.. "..,�s,/„ - ,.,Lea 'R.c... f'0•' D+4' MAX STEEL OR WOOD POST 1' MIN. BELOW LOWEST RIGID PIPE FLEXIBLE PIPE $ BANK LEVEL (MIN) INCLUDES REINFORCED CONCRETE: INCLUDES CORRUGATED METEL, HOPE, -�� a � NOTES: WOVEN FILTER FABRIC 0 1. A STABILIZED ENTRANCE PAD OF 2-3 INCH WASHED STONE OR RAIL ROAD BALLAST SHALL f1 AND DUCTILE IRON PIPE AND PVC PIPE O __ BE LOCATED WHERE TRAFFIC WILL ENTER OR LEAVE THE CONSTRUCTION SITE ONTO A NOTES: GROUND LINE o _ I DATE: 0710212014 GENERAL NOTES o O - PUBLIC STREET. ; _ FILL SLOPE / � 2. FILTER FABRIC OR COMPACTED CRUSHER' RUN STONE MAY BE USED AS A BASE FOR THE 1. WIRE SHALL BE A MINIMUM OF 32" IN N SCALE: As indicated RIP RAP 1. BEDDING SHALL BE CLASS I-A WORKED BY 6. SELECT BACKFILL NOT UNDER PAVED AREAS -� Of $° o o WIDTH AND SHALL HAVE A MINIMUM OF I CONSTRUCTION ENTRANCE. SECTION B-B HAND. IF GROUNDWATER IS ANTICIPATED, CAN BE CLASS IV-A COMPACTED TO 95% ��&�� O o, _ 6 LINE WIRES W/12" STAY SPACING. 6" "' EYP PROJECT NO.: 6013031.01 GENERAL NOTES: FLOW #5 WASHED STONE THEN BEDDING SHALL BE CLASS I-B STANDARD PROCTOR. 3. THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR > MIN. COMPACTED TO 95% STANDARD PROCTOR. 7. ALL MATERIALS ARE CLASSIFIED IN ACCORDANCE :.. FILTER FABRIC SHALL BE A MINIMUM OF WITH ASTM D 2321-LATEST EDITION. �� FLOWING OF SEDIMENT ONTO PUBLIC STREETS OR EXISTING PAVEMENT. THIS MAY REQUIRE 1. RIPRAP SHALL BE NCDOT CLASS B. A 2. HAUNCHING SHALL BE WORKED AROUND THE PIPE PERIODIC TOP DRESSING NTH ADDITIONAL STONE AS CONDITIONS WARRANT AND REPAIR 36" IN WIDTH AND SHALL BE FASTENED - � BY HAND TO ELIMINATE VOIDS AND SHALL BE CLASS 8. ALL MATERIALS SHALL BE INSTALLED IN CLEAN GRAVEL {NCDOT s ADEQUATELY TO THE WIRE. 0- CLEAN CLEAN OUT OF ANY MEASURES USED TO TRAP SEDIMENT. I-A OR CLASS 1-8 OR CLASS II COMPACTED TO MAXIMUM 8" LOOSE LIFTS IN ACCORDANCE �p 2. LOCATE CHECK DAMS AS INDICATED ON PLAN. 95% PROCTOR. WITH ASTM D 698. CLASS III AND IV-A OR �57 STONE) ON A 2:1 �i. STEEL POST SHALL BE 5'-0" IN HEIGHT a_ I SLOPE NATH A HEIGHT OF 4. ANY SEDIMENT SPILLED, DROPPED, WASHED, OR TRACKED ONTO PUBLIC STREETS MUST BE �� wN MATERIALS SHALL BE COMPACTED NEAR 16' AROUND THE WIRE. LLJ AND BE OF SELF FASTENER ANGLE I 3. INITIAL BACKFILL SHALL BE CLASS I-A OPTIMUM MOISTURE CONTENT. SMOOTH TO AN EVEN GRADE REMOVED IMMEDIATELY. STEEL TYPE. j''T ' § � WORKED BY HAND, OR CLASS I-B OR CLASS II B B NOTES _ y; DESIGNED BY: AWK rn W{r COMPACTED TO 95% STANDARD PROCTOR. 9. FREE SALVAGED DEBRIS,FROM ORGANICS VANDNROCKSSHALL BE 1. INSPECT INELTS WEEKLY AND AFTER EACH 5 ENTERINGPAOPUBLIC STREET. WHEN WASHIINGAISEREQUIRED REMOVE SHALLSEDIMENT DONE INTO AREA 4. WOOD POSTS SHALL BE A MINIMUM OF 6' IN . 4. INITIAL BACKFILL NOT UNDER PAVED AREAS LARGER THAN 3". SIGNIFICANT INCH OR GREATER HEIGHT AND 3" OR MORE IN DIAMETER. WIRE DRAWN BY: CAN BE CLASS III COMPACTED To 90% ( ) STABILIZED WITH CRUSHED STONE WHICH DRAINS INTO AN APPROVED SEDIMENT BASIN STANDARD PROCTOR. 10. ALL TRENCH EXCAVATIONS SHALL BE SLOPED, RAINFALL EVENT. FABRIC SHALL BE FASTENED TO WOODEN CHECKED BY: RTF -... -, SHORED, SHEETED, BRACED, OR OTHERWISE 2• CLEAR THE CNE WIRE OF DEBRIS 3. REPLACE STON. AS NEEDED € I / 5. SELECT BACKFILL SHALL BE CLASS I, 11, OR SUPPORTED IN COMPLIANCE WITH OSHA POST WITH NOT LESS THAN #9 WIRE STAPLES 1-1/2" LONG. •• '"" III COMPACTED TO 95% STANDARD PROCTOR REGULATIONS AND LOCAL ORDINANCES. / WITH TOP 24" COMPACTED TO 100% ANCHOR FILTER FABRIC SKIRT STANDARD PROCTOR. AJ PLAN TEMPORARY ROCK CHECK DAM N.T.S. 13 TRENCH DETAIL N.T.S. 10 HARDWARE CLOTH AND GRAVEL INLET PROTECTION N.T.S. 7 STABILIZED CONSTRUCTION ENTRANCE N.T.S. 4 TEMPORARY SILT FENCE N.T.S. 1 SITE DETAILS C702 EYP Architecture & Engineering, PC -- - - _ 811 West Hargett Street BLOCKING DIMENSIONS 4„ SQ. Raleigh, NC 27603 PIPE SIZE Tel: 919 833 8818 A g Q Fax: 919 833 6898 UP TO10" 4' - G" 2' - 6" 1• - 6" FIELD ADJUSTMENT INSTRUCTION t2" To t6" 5' - o" 4' - 0" 2• - 0" yP 12" To 16 G" 3' - 0"a' - 0" 6' - ARM ASSEMBLY ° e ae.com ° 1 . REMOVE THE BODY FROM THE° TOP OF THE INDICATOR POST 6,> DIA. ODY 1" SQUARE MAX.=10" CONSULTANTS: ASSEMBLY. EXTENSION 91, MIN.=7" Structural Engineering: UNDISTURBED SOIL GRADE o°o SHUT III A BACKFILL -III "C" ENCLOSURE Stewart Engineering, Inc. III 2. CUT THE REQUIRED LENGTH OF CONC. BLOCKING 421 Fayetteville St. Suite 400 I = = THE BOTTOM OF THE STAN PIPE po Y 11 FOR THE GROUND LINE TO ATCH 36 o Raleigh, NC 27601 II •, . I II I II II B WATER ENTRY UNIT STANDPIPE Tel: 919 380 8750 -IITll� �' III-I PERSPECTIVE VIEW UP WITH THE STANDPIPE GROUND LINE MARK. 30 (PAINTED RED) Fax: 919 380 8752 Li -III III I�UNDISTURBED 3. CUT THE 1" SQ. EXTENSION AT A Civil Engineering/ Landscape Architecture: SOIL PVC VENT SCHEDULE 4o Cole J nest &Stone, pa p PVC ELBOW PIPE PLAN - BEND SECTION - PLUG PVC END CAP PVC PIPE DISTANCE OF 9" ABOVE THE TOP SEE SECTION FOR DEPTH B SEE PLAN FOR LENGTH A NOTES: OF THE STANDPIPE. GROUND LINE 119 East Hargett Street, Suite 300 1. 2500 EL SEE WATER SURFACE 4. SET THE "OPEN" AND "SHU " Raleigh, NC 27601 2. REMOVE LOOSE EARTH AND POUR AGAINST UNDISTURBED SOIL Tel: 919 645 5964 3. BACKFILL TO EXISTING/FINISH GRADE AFTER CONCRETE o0 00 TARGETS FOR THE APPROPRIATE HAS CURED FOR 24 HOURS. o00 000 PVC END CAP VALVE SIZE. Fax: 919 719 1819 4. CONCRETE SHALL NOT COVER FLANGES, BOLTS, MEGA-LUGS, RODS, ETC. GRADE SCHEDULE 40 A ��UNDISTURBED 01 _ PVC PIPE 3.0" PVC PIPE 5. REATTACH THE BODY TO THE Plumbing Mechanical Electical & Fire Protection: -III III III III-fII=� BACKFILL I II 1/2" HOLES IN _ UNDERSIDE TOP OF THE INDICATOR POSTrrn EYP, Inc �I- CONC. BLOC IN PVC TEE ORIFICE ASSEMBLY. THE CH PVC TEE PLATE DEPTH 420-I-A The Parkway -III- Greer, SC 29650 FLEXIBLE 42" MIN. Tel: 864 334 0997 HOSE VALVE Fax: UNDISTURBED SOIL CONNECT TO PLAN - TEE SECTION - BEND & TEE ''� I/������III�j��� �`N CA/�OC �ii�� SEE SECTION FOR DEPTH B SEE PLAN FOR LENGTH A BASIN OUTLET STRUCTURE 1 � & ���\ ���I END VIEW FRONT VIEW IRE SERVICE LINE, ``� RpoRq TOE` =p��oFEssio����' THRUST BLOCKS '= DETAIL W-9 PER PLAN ; �, SEAL = ; •Qc_c� - J C-1361 \ � `p zoo c-103 � ; 5 v -•TNCARo� - �` •F ``�� •�� •••Ne NEB ,:�����• THRUST BLOCKS N.T.S. 1� SEDIMENT BASINS N.T.S. N.T.S. ���������� ��"ODD••F SKIMMER 9 3 ---IIII„►\ 10/06/14 M SOLID COVER SHOWN PERFORATED. PERFORATED AVAILABLE z H7� IF SPECIFIED. �} NOTES: H• STATE USE OF SYSTEM ON COVER Q Q 1. LOCKED HYDRANT &LOCKED HYDRANT ADAPTER OR MUELLER 'AQUAGRIP" D H O 7 (I.E.: SEWER, STORM DRAIN, ELECTRICAL) _jr V SYSTEM MAY BE USED IN PLACE OF RESTRAINT RODS. r-O-n�t» -_ / 2" HOC'3 M Q '� /' LL J H Z 2. VERTICAL MUELLER AQUA GRIP FIRE HYDRANT SHOE MAY BE USED WHERE � > �.� TOP OF COVER --- O 0 Z= MAIN DEPTH IS GREATER THAN 5-FEET. z _ >D m O //F � �`� `� {LLJ Qj p= 3. USE SWIVEL HYDRANT TEE WITH 6" GATE VALVE DIRECTLY COUPLED TO VARIES s `5 �Cd7OO k? � a A r`�� �,� BI Q rOr HYDRANT TEE UNLESS OTHERWSE APPROVED BY BRUNSWICK COUNTY, w zHor n / /r \ O ,..� r(�y \\�\ `\ ��'y ��� LL J 4. FIRE HYDRANT COLOR SHALL BE "CHROME YELLOW" ENAMEL PAINT. 1 C7 S T1 ) i V��� O Q I PUMPER NOZZLE 7 j,/� j4j)/((� ` ? 5. FIRE HYDRANTS INSTALLED WITHIN THE NCDOT RIGHT-OF-WAY MUST BE TO FACE STREET4 z -I I �\ L VU' v � V H > I ,. 1( ti•,•, z H -{ I -- �� - > INSTALLED WITHIN 12 INCHES OF THE R/W LINE. AT 90' J H , CL CHAIN REQ'D 1 REVIEW COMMENTS 06111114 f Imo--- ,--- 1/2 R�� �� 27" CONCRETE VALVE COLLAR I LID I f - __ 1 " FLUSH WITH GRADE MARKED z 2 BID DOCUMENTS 07/02/14 BOTTOM OF COVER {� jR` ' R" I CURB STANDARD DETAIL) "WATER" o N SIDEWALK (SEE VALVE COLLAR 3 ADDENDUM 1 ROAD 6" 07/25/14 ' v '�_____� •' PLAN OF_._COVER Bc '.. •--: _. . ,//� ' / �//� //�//�/i\ 4 REVIEW COMMENTS 07/31/14 "' \ / /� /��// ����i \/�\\/ HYDRANRI SHOES SEE Z z PLAN OF FRAME = H -•---1'-111/2" C3 O VALVE BOX a 1/2 CUEYD 5 NCDENR EROSION CONTROL 10/06/14 O H O SWIVEL HYDRANT 6" GATE VALVE CRUSHED\` N FOR HYDRANT 6 NCDENR STORMWATER 11114114 r = m 2 11�4 0 TEE W/6" BRICK DRAINAGE Cf) Q Z BRANCH SUPPORT D --_ cr ._. ..__j` 113/4"-- - " m - Q I CONC THRUST BLOCK BEARING AGAINST 4 SQ �+ i "` 1 8rr- ( (+I TBLOCK -3 MATERIAL TUBBED CC M m v ..._........ t Q 6 _ (SEE CONCRETE THRUST BLOCK TYPE #1zQ 4 - - e• SCHEDULE) D I 3 n y 1/2 rr = ��\ e' •• •� \ 6 0 DIP PIPE CONCRETE FILL LU \ \ �- per' Il- i - 1'-1 o5/B" C -I'I �`"�v �. ALTERNATE Z 2'-D" MIN # Revision Date p f' Z PROVIDE 4-3/4.0 STAINLESS STEEL TIE RODS THREADED AT ENDS(INC. NUTS) � � � � fi _ �, SECTION B-B w � VALVE SUPPORT 4/B" _►�----- 2`-0/2„ ' ^ MINIMUM WEIGHTS - LBS EQUALLY SPACED AROUND PIPE JOINT FITTINGS (TEE, VALVE, BEND) TO BE FULLY FUNCTIONAL 3 1 BETWEEN ALL MECHANICAL NOTE: WEEP HOLES ARE _3,_gib„ __ _ -_._ ,,. FRAME - 180 COVER - 120 OR MEGA-LUG SCO I D#• 07-07054-02J SECTION A-A I TOTAL 300 SPECIFICATION FIRE HYDRANT f< CLASS 30 IRON MEETING q SHEET 1 OF 1 ASTM A-48 SHEET 1 OF / DETAIL W- 1 840.54 TYPE #2 840.54 N.T.S. MANHOLE FRAME AND GRATES 11 FIRE HYDRANT N.T.S. a E z <-) 6" .- A 6„ ----OPTIONAL MANHOLE H?' f'Q H Z __. ._.._ E Q ?7 U)O O I -- �-1 GENERAL NOTES: Z F-=V ■ r p-1, Cn Y -_- C CHAMFER ALL EXPOSED CORNERS 1". LL J z Community Service Z > i USE CLASS "B" CONCRETE THROUGHOUT, O cc Cn Z !7 O CO --- -_____.___....- OPTIONAL CONSTRUCTION - MONOLITHIC POUR, 2" KEYWAY, OR w Q.Q V-_ ,, - ■ _ p D t11 x � O ; I #4 BAR DOWELS AT 12" CENTERS AS DIRECTED BY THE ENGINEER. I-U Q O(.3' Learning Center #8 d m ci D 7 r ' USE FORMS TO CONSTRUCT THE BOTTOM SLAB. S~z H D „. p ---- IF REINFORCED CONCRETE PIPE IS SET IN BASE SLAB OF BOX, f-t 1..........._.� O a GATE FOR DUMPSTER PAD ONLY ADD TO BASE AS SHOWN ON STANDARD NO. 840.00. O U3 pC Brunswick H PROVIDE ALL JUNCTION BOXES OVER 3'-6" IN DEPTH WITH STEPS I-H ri , 12" ON CENTERS IN ACCORDANCE WITH STD. NO. 840.66. a p z _- 3 - '- East Carolina University 6' 3 ADJUST THE STEEL, CONCRETE AND BRICK MASONRY QUANTITIES HEAVY DUTY TO INCLUDE THE ADDITION OF THE MANHOLE (I.E. DIAGONAL BARS 8'-0, 6 -O' MAX. Y SEE STANDARD 840.54 j C SHORTENED AROUND OPENING IN TOP SLAB, ADDITIONAL VARIABLE „ HINGE, TYP. _ r---FOR MANHOLE COVER & FRAME ! N4 BARS "A" HEIGHT BRICK MASONRY, OPENING IN TOP SLAB.) 8 x8 POST WITH School of Dental Medicine PLAN i OPTIONAL SPACED 6' - 2"X6" CAP WITH -- C. TO C. MAX. DEPTH OF THIS STRUCTURE FROM TOP OF BOTTOM SLAB TO TOP CHAMFER TOP. CHAMFER TOP / �---BRICK MAY BE USED ELEVATION IS 12 FEET. • (TYP.) % TO ER.ITO FRAME & 1 Brunswick County NC 6 COVER TO SURFACE 1"X6" INFILL I - ELEVATION MAX. 1' #4 BAD. 3/8" SPACING BTW. BOARDS C'? SLIDE ACTION O m I Or LATCH o 6"x6" LINE POST Z H OUTLET PIPE. y =. 00 J II I WITH CHAMFER TOPCD °1 H o _ _ - z o w 6 E OR F� 1 2 00 N S m '-= -1 - A.. r' o -. r r. /+ T 6 -..-_._ Q Q 2"x4" BRACE, TYP. O INLET.PIPE _ SECTION � -oRty 6 - DOWEL o DATE: z o _C C OR -©-D � 0710212014 c O c D SECTION.._._X_-X SCALE: As indicated rn y Z p - - DIENSIONS AND QUANTITIES FOR CONCRETE JUNCTION BOXES Q ! - I I f I EYP PROJECT NO.: 6013031.01 CO r O 0 DIMENSIONS 4F 60X AND PIVE I TOP SLAB - 0 „.._, _.__. .___.__.. - ___.__.._._-._� REINFORCEMENT DIMENSIONS CUBIC YARDS TOTAL QUANTITIES DEDUCTIONS FOR ONE a- _ ��/ Q _ CONCRETE- I .I I; r ,o IPE SPAN WIDTH HEIOMT O FOOTING N 6" PIPE _ arms ^A" _ _ -_- __ IN BOX Box AND SLABS PIPE GU.YDS. I- " i �� j I Z2CANE BOLTS. DRILLU T OP BOTTOM MALL7 LBS. CU. YDS. C S R.C. _ L�__ .,° z O H �x 61, i W z N HOLE IN CONCRETE. s Z z �XP. �oiNT D A B H la. ILENGTH E F LAB FT FIELD VERIFY LOCATION. O SLAB S OFHT. REINF IMIN "N" H V I- '� 1 - .. - 12 2 0 2°-0" 2'-3 12 2'-9" 3'-0" 3'-0" 0.167I 0.167 0.1a51 22 0.750 0.015 0.024 ar GENERAL NOTES: 15" 2'-3° 2'-3" 2'-6" 12 3'-0" 3'-3" 3'-3" 0.196 0.196 0.204�24 0.902 OA23 i 0 O36 (� O ��� 1. ALL WOOD TO BE CEDAR. O 18' 2-6 -..-2`-6° I-..2,_9- I 14 3'-3" 3'-6" 3'-6" 0.227 0.22r 0.222 30 1.065 0.033 0.049 V %ii a ' '�%• ' TO BE USED. fi', _ - - w DESIGNED BY AWK ES 16SE 24" 3`-0" 3'-Or' j 3-3 16 3`_9° 4 0" 4'-0" 0.2$8 0.298 0.259 40 1.434 0.059 , 0 0853. GAT VA IZED ST, " 4. APPLYN2HCOAS SEMITRDANSPARENT STAIN.30 3 6 3-6 3-S 18 4 3 4 6 4 8 0.375 0 3 5 0.296 51 1.860 0 092 0 127...... DRAWN BY: 36° 4 0" 4 0" 4-3'' 20 4'-s" 5 0' S'-o" 0.463 0.463 0.333 s4 2.3a1 0 1s2 0 17a COLOR BY ARCHITECT. r SUBGRADE E NOTE,. 3 DEL 42 4'-6" 4'-6" 4'-9 22 1 5'-3' 5'-6" 5`-6` I 0.560 0.560 0.370 77 2.87a 0.180 0 243 �. �- - CHECKED BY: RTF 48' 5'-4" 5`-4" 5`-3" 26 6'-3" 6%4" 6'-4" 0.743 ' O.743 0.407 11i 3.623 0 235 0.317 I. - SECTION Y-_Y 54° 5 io" 5'-10" S'-9" 28 6'-7" 6 1A" W-10" 0.865 0.865 0.444 1 126 4.283 I 0 29T ; 0.401 s NOTE. _ W_ _ - SHEET 1 OF 1 80" 6 6" 6 6" 6-3 30 T-3" 7 6" T-6" 1.042 I 1.042 0.481 145 1.09 0 D 367 o.as5 SHEET 1 OF 1 DETAIL PROVIDED FOR GENERAL DESIGN CONCEPT ONLY. CONTRACTOR SHALL PROVIDE DESIGN-13UILD 840.3 1 66+' 7-1 T 1" ' 6 YDr 32 ; T-10" i 8 1" 8'-1" 1.210 I 1.210 0.518I 169 5 917 o aaa 1 o.5ss 840.31 INSTALLATION SERVICES FOR SCREEN FENCE' AND SUBMIT SHOP DRAWINGS FOR APPROVAL CONCRETE MANHOLE N.T.S. 10 FDC SIGNAGE EXAMPLE N.T.S. 7 DUMPSTER AND MECHANICAL EQUIPMENT SCREENING AND GATE N.T.S. 1 SCALE: 1" = 30' N SITE DETAILS C703 0 15 30 60 1-%Ir% A --I-! L; I F- M1%,111tUtLUIW M Engineering, PC YP/ 811 West Hargett Street Raleigh, NC 27603 - ­­-- - 12 z W 0 M M-NENAL NOTES; 'E" �n Tel: 919 833 8818 . ..... . . I" DEPRESSION t_4 z y - USE MAW MNMETt THROXWOUT, A to 0 ZFOP INLETS OVR 1 6" IN OePT4 WTTH STEPS' t1' 0 _n WWto` WITH STO, 04JOVIr& 00,", IF11,; 0 Fax: 919 833 6898 r- a'" to 7% F > V- 7% to rj­ H I C),., z -4 Cn ON M SIEPS WfCM rno OPT104& VOWITAIC, PlOUA 2" *rymy CA 04 am DMIS AT U. CL eypae,com 00-'D0--q I I I , X-n> M 1 1 14 1 a 4 Z13 I G E E *-4 -0 -M =Z Uj 6< 4- I- CCOO < pya , I I , , X I.-- IEXTfRS AS D0ECTER AV TW_ FOINFER, C. Zn > > M Vat F04*6 r,0" TW 0AASTW,114A Of 'THF BOTTOM SLM� Z = rn 0 i" IF PCINFOKED Gt",ETE PIPE 18 SET IN BOTTOM SLAU Of BOX, ADO 'TO 4LAS I AA vto" CO 5TP Na8401001 . W;5 �E U_ LU 1- LL 0 CONSULTANTS: in It, " I LL C) ... ... ...... wwk" WNVWXIT `41141 PIPE CWJ04S tAfC44INQ, 0�00-w� cc, Structural Engineering: . ............. INSIAu_ 2' WUPHIII-ES AS 01W-CM) 01 blE R INKTXIL 3,70"E PAAINS, OF A #j'fd*;W W I CU410 FMr OF NO, ?W 5TANE IN A F: tit Stewart Engineering, Inc. .......... . .. . . . ... ............ �.4 PORWS FARRIC RkG OA WAVP, AT "" W-fY HOLE OR.M 010WECTS0 By THt SWINFER, Ca 421 Fayetteville St., Suite 400 T. - - ----- -G SECTION GH EiK"V, EXO COMEAS T10 Raleigh, NC 27601 VARIES SEE PLAN 1 1%4 F Y _ OAAWING NOT SGAoa P-L"AN Tel: 919 380 8750 PLAN OF FRAME in Fax: 919 380 8752 4" MULCH THROUGHOUT 110 74to 0 pl, 1.7% CAST IRON WITH "Alf 4 FHAWE PENOV0 PLANTING BED Go 44p, Civil Engineering/ Landscape Architecture: 'P M M PLAN OF GRATING TAL) rn Cole Jenest & Stone, pa ADJACENT PLANTING ip AREA OR PAVING #-4, a) CAST IRON Z LL CC < z . . ................ . ......... .......... TIP FLWATTON 0 0 FRAW, U_ LLJ 119 East Hargett Street, Suite 300 --1 1-4 3: 2 (0 STU, W, 16 z A MATE x C') . . ....... . .... It A # EAR z Uj Raleigh, NC 27601 W M -4 �t a: C) I . A A, _MM CL Tel 919 645 5964 Oil > R4 rA CD > M Fax: 919 719 1819 Plumbing Mechanical Electical & Fire Protection: 21 . ............ .. 2" H M x ;;k a I& a JIJ6 < 16 I =0 00 . ILU < EYP, Inc 420-1-A The Parkway PLANTING MIXTURE/ W 4* > I to 0 7- SECTION H-H ..... DOWEL to W Greer, SC 29650 AS SPECIFIED - 3�-2" I . . . ... ... .. 2"'! Z_ im Io­-__ -0 1 1 LU -0 0.4 DWL(SEE WTE) IEF RME - Mo. PIPE THIS SIDE - Is, M X 8" 10" DEPTH 1 t T M SECTION X-X SECTION Y-Y Tel: 864 334 0997 > . . ........ _j -4 Fax: -4 W t& RA H) M bilhiNkGRZ AND WANTITAi OF INLET( SED ON MIN REIGHT W, IN V4 1441, 2? -,1,4 . ...... ..... . ........ . ..... . . . ..... Uj ]IT&MMtWS, OF Box a PIPE CURIG YAMS M"Flo" fo ------ PIPE OPA Wjj)TH_MIN, HEI,04T' 00fir. IN RON ONE PIPE El 4f m, a, c, SLAff PT, KI, W off// CARO & ....... . ......... .. . .... ... ... 13,;�22 0 Sot 01015 1 U-026 �V�SS/0*%. SECTION E-E SECTION F-F 0,D59 G,C65 if-3 - C, 4§1 Lj SEAL 14- Nq '-1361 %_q _j 1, D­­ 3�17 092, 0, 127 __EET L4 7- C 103 it 0 40.16 840.16 F_E_4­0_� �16 840-14 840.14 0 .......... 1 N6. '4� GROUNDCOVER DETAIL N.T.S. DROP INLET FRAME AND GRATES N.T.S. CONCRETE DROP INLET N.T.S. 00 MM0 10/06/14 c 0( M z < 43" - tM TIPE `W' AND 'G" ORATE NOTE, UMLESS OrTHERWISE NOTED. _�4 p �!501 P �r ............. .......... fXPA"TON JOINTS < . (JO. I 1 F­ cc 0 ­4 1 z X > 0 LL _j 0 CL 1 0 M > LL _j 00M= Z Uj<<U_= >>m 0=00 z z 0 W > R U A A ALIGN FRAME WITH INSIDE WITH INSIDE L TO ALLOW EDGE OF WALL. TO ALLOW "ADJ f-: 0, > j PLAN Q�URR AM WTTEA WITH CATa4 WIN ON STEEP GRADES 0 FOR VCRUM ADJUSTWNT,__ L USTWNT I REVIEW COMMENTS 06111114 WALL "Ll 4C JON TOP ELEV�_ USE ON FLAT EXPANSION JOINT AND 2 BID DOCUMENTS 07102114 WWES. 2% UWER + + + 00 PLAN 0 j f RAME, GRATE S HOW ASSY z L . . ...... . W GUTTER LINE EXPPMTON JOINT M PLO OF TOP, 41�0 TIQN -4 3 4 ADDENDUM 1 REVIEW COMMENTS 07125114 07131114 tv tL, < NOWAAL CURB - AM WTTOV 4W LIGNT WAVES 5 NCDENR EROSION CONTROL 10106114 + + + + 2. 1 fill T 4- t s. Cn z - 0 0 -­­"VAL WITEA LINE pa CXPANISIOR JOIN7--, Z M CA E 00 "W" BARS TOP -4 -4 W a. 6 NCDENR STORMWA TER 11114114 > C= A K -K- 12* M J > -4 f 0 M L M f. U1 pHtsm am" LINE, U-) D DIMENSION OF PLANT SPACING (SHRUB OR GROUND COVER) AS INDICATED ON PLAN 1 1, f_ u -4 C7 kkx . . ........... _ ---- ­V-­­, =0 a tit X S,f> > f.00111VEL 'j- L ;z R-R NOTAAL CUM AM CArFTM ON STEEP GRAMS Uj 9 Will 44" co W 0 M > z 0�]Wlthw AM W$WT1T1M FOR COMW",rAl" 8A:S1N(RA4M GR RIX. HEIGHT, A,_ W1_Tft1_"_1�V"_)_- S OF SOX iikl PIPE 07WER Cu Tw, Moe, IN #-4 i tv tiA as Revision 3# M 'U PAR$- V �4ti W U m SPAR Tot T014,1, TrAl foTTOW, 0 WID Date Cf) _n, P, IX'l tL Uj W) 33 15 j, 0 2' -- ---- . .......... .. . . . . .................... ....................... ............ ........... ............. .................... . . ..... ... . .. .. .. ..... W 311: 444 . J� 'k, 4' 3� SCO ID#: 07 -07054-02J I -A" J a' 2' 2" 3' fa V-161 Q. 1 .14 L . . ..... 4'- 5 4 1'4' F-1i a 4 7"i 4' 1' 2" i 4 -j_ I,' mai i X-61 J 2'- 7 1' 35 11. 14 0. T, 7 .1 41 r"lar, 30 ...... - - ------ EET 1 2 R do" SIECTIOIN ............... ........... r84=0.03 I 2 840.03, F4 fl-10 •RIU-R HAS V.28 QAIC YA" OF COPMEn PER FOOT HEMW 8"O�.021 840.02 rr 0/000 1 PLANT SPACING DETAIL N.T.S. FRAMES, GRATES, AND HOOD N.T.S. CONCRETE CATCH BASIN N.T.S. NOTES swu a CUM ­ FV% C AND. qw, LMSE Ck.ASS 'S' OMMIrt THIM"Wl- SET ROOT COLLAR AT SLOPE LINE 1 RUBBER HOSE MAY BE DELETED IF 3/4" NYLON STRAP IS USED (GUYING OF TREES NOT REQUIRED UNLESS SPECIFIED). r"No.- X FROVIPE, NA CATQI WINE We" W-6" 10 OWTH WITH 5TI�,FS 12" ON CENT01. USE StVPS WHICH ammy Wtiv sm. mumme a4o.jt$, O!Tzmw WNSTRucTum - WW%TMTC POW, 2- W"bky, QA #4 W WAFL19 AT F- < -4t .1c F_ I . Community Service 12 MILMM AS D14eMO BY rAE MO ffl�gt. y t U� _j a: EXISTING SLOPE 2 2. REMOVE WIRE OR NYLON TWINE FROM BALL. Z USE, FOM FOR TK. CONSTPUCrION (W THE WITTM SUS� > 10, CONCRETE PIPE is Ser Ill affm SLM (W WX, AWTO SIM -n > > m AS &iOft 0% STD� �tl, B40�00� oc>wzz <z Learning Center #8 NOTE: 3. INSTALL TOP OF BALL 2" ABOVE FINISH GRADE �t F < SHRUB SHALL BEAR SAME RELATIOa�� i : �.� w (ADJACENT UPHILL GRADE). __ _ r �:�REIWOMA-13 � �� _ fmm �I�T��. C5 F I.- C) 4 TO FINISHED GRADE AS IT BORE /< TO PREVIOUS GRADE EXCEPT IN 0/ . .... AREAS OF COMPACIETID FILL , </ 4. SOAK ROOT BALL AND PLANT PIT IMMEDIATELY AFTER INSTALLATION. a''O- IN 1w-f OR LESS USE is" UNLLS JARD BOTTOM aL4B- Wf_4 16 is; a- 'IN Hkmir USE a" WALLS a 0a AM SUrtOk ALO&_ AW140, > 4-j 3. fo , COWPOCT WITH PIPE CROONS MTCMIMG- PW CHANSFIT ALL FAME0 OWNERS t', U_ C? Brunswick 0." SHRUB TO BE PLANTED 4" " � X­ ABOVE FINISHED GRADE. 5. LENGTH OF RUBBER HOSE TO BE 2/3 CIRCUMFERENCE X SEcTXD#_X r" East Carolina University OF TREE. Y THIN BRANCHES AND FOLIAGE ........... 111MI., . ....... . 1/3 School of Dental Medicine (NOT ALL END TIPS) BY x" RETAINING NORMAL PLANT N V, 6. PLACE TWO(2) WOOD STAKES PARALLEL TO STREET. rdrk,? ZATE*"N11?01d0110 Sim ars- No-STEPS $TV. 840," SHAPE. THINNING NOT SLOPES 7. 4" SAUCER WILL BE OUTSIDE OF BACKFILL. Brunswick County NC REQUIRED ON EVERGREENS 8. SEE SPECIFICATIONS FOR OTHER PLANTING REQUIREMENTS. 1 4" POLY ROPE OR 3/4" NYLON STRAP RUBBER HOSE - M z 4- U. 9. THIS DETAIL APPLIES TO SINGLE STEM TREES AND Z I., . ............ FINISH GRADE MULTI -STEM TREES. 4" LAYER OF MULCH (NO MORE THAN 4- TOP OF ROOT BALL TO 10. SET TREE IN VERTICAL POSITION PRIOR TO STAKING. TOUCHING TRUNK) M SECTION Y-Y W to ABOVE FINISH GRADE -4 CL DATE: 4" MULCH THROUGHOUT BE 2" . . . . .......... . ... ... . ..... 07/02/2014 PLANTING BED 4" HIGH WATER BERM 11"X2"X18" WOOD STAKE SCALE: As indicated REMOVE BURLAP FROM WITH CENTERED 31e� H� COMPACT FILL TO 0 > = ....... ... . ...... i -4 0 j EYP PROJECT NO.: 6013031.01 TOP 1/3 OF BALL. REMO /E BE BENCHED IN REMOVE TOP 1/3 OF BURLAP, ............ ........... t3 SECTION J-j 1L z Uj a: CONTAINERIZED PLANTS FROM THEIR CONTAINERS ALL TREES SHALL MEET AMERICAN STANDARD FOR NURSERY AND ANY NAILS/PINS, ETC. "SHADE "RF'_3O"T0 U, PIPE ta 0A'a 0_4 9fr, NOTE _0 to LU t MOUND TOPSOIL 4" STOCK (ANSI, 1990, PART 1, AND FLOWERING TREES-) 2 MAX SLOPE REMOVE TOP 2/3 OF WIRE 1 *WW 4r TO 54' PIPE tS UM M > z *aA Sol, to w, pt" n uavo, (a 0 STUR KT� 29 TO FORM SAUCER '7 KEEP SAUCER LEVEL BASKET WHERE PRESENT FOR HEIGHT MAX. MIN. ROOT MIN. ROOT PLANTING MIX EXAMPLE: CALIPER (RANGE) HEIGHT BALL DIA. BALL DEPTH UNDISTURBED SOIL LINE (AS SPECIFIED) 1-4 0, 40 Uj DESIGNED BY: AWK (IF SOIL HAS BEE PREVIOUSLY 7­, PLANTING MIXTURE 2" 12'- 14' 16, 24" 16" DISTURBED, FIRM SOIL UNDER DRAWN BY: AS SPECIFIED . ..... . ......... . . ROOT BALL) 3" 14'-16' 18' 32" 21 WNERE� 42" TO 44" PS" IS USIO AL CHECKED BY: RTF .......... SCARIFY TO 12" DEPTH V� . ... ....... DETAIL SUM NO AMTROD 0 A a NA'Wit-STNUMM PLO PLAN SWET I of 2 . . . . . . .. . . . . . . ........ . . 6" 20" 6" 8" 8" le If 840.02 - 840.02 EL GROUND 48" SHRUB PLANTING DETAIL N.T.S. 13 TREE PLANTING DETAIL N.T.S. 7 CONCRETE CATCH BASIN N.T.S. SCALE: 1"=30' N SITE DETAILS C 7 04 0 15 30 60 EYP Architecture & Engineering, PC 811 West Hargett Street YP / NOTES: Raleigh, NC 27603 NOTES: Tel: 919 833 8818 1. A MINIMUM OF 6" FROM OUTSIDE DIAMETER OF PIPE TO SIDE OF TRENCH MUST BE 1. REFER TO SHEET C601 FOR PLANTING REQUIREMENTS. ALLOWED FOR WASHED STONE. AN APPROVED FILTER FABRIC SHALL BE PLACED Fax: 919 833 6898 AROUND STONE AND OVERLAPPED 8" AT TOP. PIPE TO BE SCHEDULE 20 OR 40 2. 4-6 INCH LAYER OF AMENDED TOPSOIL IS REQUIRED IN ALL PLANTING AREAS. BERM CONSTRUCTION SHALL PERFORATED PVC EXCEPT AS NOTED BELOW. 3. FOR TEMPORARY SEDIMENT BASIN, CONNECT SKIMMER OUTLET TO ORIFICE eypae.com LINING PER SCHEDULE OUTLET CONSIST OF SELECT FILL HAVING A 2. OUTLET PIPE FROM SUBDRAIN SHALL BE NON-PERFORATED UNDER PAVEMENT 6" MIN. C 3:1 SLOPE ABOVE UNIFIED SOIL CLASSIFICATION OF CL (INCLUDING SIDEWALKS AND DRIVEWAYS). FREEBOARD PERMANENT POOL � CONSULTANTS: 3. THE OUTLET PIPES SHALL BE SCHEDULE 80 UNDER ROADWAYS. SEE SITE PLAN FOR ELEVATION, TYP. I I SLOPE OF SUBDRAIN AND TIE IN TO STORM DRAINAGE. MIN. TOP WIDTH, W �- TOP OF BERM Structural Engineering: 4. FILTER FABRIC SHALL BE AN APPROVED, TYPE 2 WATER PERMEABLE, SYNTHETIC 50 YEAR LEVEL = 35.45 ELEVATION = 36.0 Stewart Engineering, Inc. FABRIC. � __ �'� �„ 5. ALL SUBDRAINS WILL TIE INTO A STANDARD DRAINAGE STRUCTURE OR DAYLIGHT TO _ 10 YEAR LEVEL = 34.93 `Aw. 421 Fayetteville St., Suite 400 THE SURFACE AS SHOWN ON PLAN. - Raleigh, NC 27601 1 1 WQ LEVEL = 33.83 PERMANENT Tel: 919 380 8750 ZR = POOL L V Fax: 919 380 8752 ZL SEASONAL HIGH - - -33.0 WATER TABLE -,...: Civil Engineering/ Landscape Architecture. ELEV. 33.00f Cole Jenest &Stone, pa BACKFILL �- N �����- 119 East Hargett Street, Suite 300 FOREBAY OUTF LL Raleigh, NC 27601 �M,. 9 as.1 � � . 4' PIPE A Tel: 919 645 5964 FABRIC SHALL BOTTOM WIDTH, B WETLANDS HIGH MARSH = Fax: 919 719 1819 Z HAVE 8 LAP BASE OF FOREBAY ELEV. 33.83 - 33.0 INSTALL CAP W/ ' = ELEV. 29.0, TYP. LOW MARSH = SECTION LOOKING UPSTREAM 1.5" TAP FOR 1.5" PVC CUT OFF TRENCH PlumbingMechanical Electical & Fire Protection: ELEV. 33.0 - 32.5 BASE OF DEEP POOL INLET; TURN DOWNWA EYP, Inc Lj #57 WASHED STONE ������� r 6" THREADED PLUG = ELEV. 30.0, TYP. PIPE TO PLACE INLET MIN. STRUCTURE MIN. 6" BELOW 420-I-A The Parkway 6 BOTTOM DEPTH OF MIN. TOP LINING PERMANENT POOL Greer, SC 29650 PERFORATED LONG. SLOPE WIDTH B SIDE SLOPE LINING, D WIDTH, W THICKNESS, TEMPORARY POOL PVC PIPE DITCH (FT/FT) (FT) ZL ZR (FT) (FT) LINING TYPE T (IN) Tel: 864 334 0997 * 6" D.I. TEE FITTING PROFILE A PER PLAN 3 3 3 1.5 12 North American Green SC150 - Fax: � 4 4" TYP. PERMANENT POOL K7 NOT TO SCALE LI N.O. B PER PLAN 3 3 3 1 9 North American Green SC150 = NCDOT TYPE 2 6>, c° ill, III!!II&j.� ��� N C 4/�O��i�� � � `1111 IIIII FILTER ,,�II S� & .S WN-0 ��0�� •,.........,•• ��ii FABRIC =' ••. f , r 6" CAP WITH oRPORq�T���` `���'a�oFESS�p�'y•� sm 1.5" WATER QUALITY ORIFICE W SEAL WATER QUALITY ORIFICE DETAIL ? J ' C-10', Q �25 0 �P�/CAR�fi'• `� is-�1 `� SUBDRAIN DETAIL N.T.S. 12 TYPICAL DITCH SECTION N.T.S. 9 WETLAND SECTION N.T.S. °°°,,, 10/O6/14 2.0'(TYP) 5"(TYP) STANDARD STRUCTURE 2'X2' HINGED ACCESS 5"x5%3/8" STEPS 0 15" O.C. HATCH OVER STEPS; ��S.S. ANGLE PROVIDE HASP FOR LOCKING ) LET ORIFICE TEE-TYPE CONFIGURATION 13 ��6"S.S. ANCHOR CHECK VALVE, WILKINS MODEL 700, BOLT EPDXYEO #UFMXIM-700, MANUFACTURED BY ZURN, IN PLACE OR APPROVED EQUAL in I OORRTEE SADDLE DOUBLE METER BOX CORPORATION STOP 24" RCP 3' 1 REVIEW COMMENTS 06111114 OUTLET PIPE FABRICATED 1" CTS{HDPE) ALUMINUM PEAKED SDR ) 200 PSI 2 BID DOCUMENTS 07102114 SS ANGLE CLIPS ROOF TRASH RACK (�'') (TYP OF 12) SECURELY BOLTED **NOTE: TO TOP OF -" MIP BACKFLOW PROTECTION DEVICE IS Q ANCHOR DETAIL PLAN STRUCTURE TOP VIEW W/ TRASH RACK OUTLETS, REQUIRED ON ALL IRRIGATION WATER 3 ADDENDUM 1 07/25/14 FABRICATED ALUMINUM TYP PEAKED ROOF TRASH z METERS AND ON ALL RACK SECURELY BOLTED COMMERCIALANDUSTRIAL WATER METERS TO TOP OF STRUCTURE 1" SAND ERVICE LINE FOR ELEV 34.75 --- ELEV 34.75 2 SERVICE MNEEFOR 4 REVIEW COMMENTS 07/31/14 3, (3) 2.0' WEIRS, INV= 33.83 3 t.5" AND 2" METERS RECAST 4'X4' (INSTALLED ON THREE OF THE FOUR SIDES, 5 NCDENR EROSION CONTROL 10/06/14 CONIC. BOX o NOT ON THE SAME SIDE AS ORIFICE) GENERAL NOTES Lld TEE BRANCH, FIP INLET, ACCEPTABLE DOUBLE METER BOXES SUPPLIED WITH FORD 6 NCDENR STORMWATER 11114114 1. PRECAST STRUCTURES SHALL g DG118-243-LUD BOX FORD DG 118-243-LLID o CONFORM TO LATEST ASTM INLET BALL VALVES, TYP 2' 0.75' MIN. C-913 SPEC FOR "REINFORCED NOTES: WITH LID III RT-IOXI3UD D.I. TEE FITTING W/ CONCRETE WATER AND WASTE 1. CONNECTION BETWEEN 1" CTS SERVICE LINE AND "OR APPROVED EQUAL o THREADED PLUG AT WATER STRUCTURES." TOP OPENING YOKE BOX TO BE MADE USING A 1" BRASS 1. OR APPROVED EQUAL - MUST 6" TEE-TYPE CONFIGURATION UNION. ELEV 33.0 Q SEE DETAIL 3 THIS SHEET 2. SECTION JOINTS TO BE SEALED ACCOMMODATE TWO (2) SENSUS INV=DETAIL PERMANENT WITH BUTYL RUBBER SEALANT WATER METERS WITH AMR/AMI 3' POOL l� SUPPLIED BY VENDOR AND 2. LID TO BE NON LOCKING TYPE 1.5 ORIFICE DRILLED INTO INSTALLED 13Y CONTRACTOR. 0 6" CAP INV= 32.50 PLAN VIEW FOR WATER/IRRIGATION SPLIT SERVICE d 3. EXTERIOR OF JOINTS TO BE (WATER/IRRIGATION SERVICES INSTALLED CONCURRENTLY) SEE ANCHOR DETAIL U o WRAPPED WITH 6" BUTYL � WRAP. # Revision Date #5 BARS N 4. CONTRACTOR TO ENSURE THAT ® 12" O.0 E.W. OUTLET BOX IS SET LEVEL AND AS NEEDED WYE FLUSH WITH SURFACE OF BASE 1" SERVICE LINE, TYP FOOTING TO' o• ; ... : .. •v UNIFORM � ' : .. ►.►t: :... BEARING. GROUT IF OVID NECESSARY. Oil ._ SCO ID#: 07-07054-02J r • ELEV 98.0 r "� • D" BOTTOM POND 5, ALL ORIFICE OPENINGS AND PIPE 0 6.5' �L 6.5' OPENINGS INTO THE OUTLET SEE ANCHOR DETAIL STRUCTURE SHALL BE SEALED LEAK TIGHT. 5' TYP 1" SERVICE LINE, TYP J•-1• ACCEPTABLE SINGLE METER BOXES 0 oi� FORD LYLV-141-243 TP STORMWATER BMP POND OUTLET STRUCTURE N.T.S. 8 McUELLER 776-208-PC2G437 WYE PLAN VIEW FOR WATER/IRRIGATION SPLIT SERVICE MUEUER H-1462-K (IRRIGATION SERVICE INSTALLED AFTER MAIN METER) • OR APPROVED EQUAL 1. OR APPROVED EQUAL- MUST " ACCOMMODATE SENSUS WATER METER WITH AMR/AMI 2. LID TO BE NON LOOKING TYPE Community S e ry i c e 5' SQUARE EASEMENT w FIRST BAFFLE IS TO BE FABRIC FOLDED Learning Center #8 CONSTRUCTED OF RIP RAP OVER HORIZONTAL 3 AND I5 WASHED STONE POST WITHIN MINIMUM HEIGHT OF VARIES - SEE PLAN 3' AND TOP WIDTH OF 2' NOTES: HORIZONTAL POST I Brunswick 1. DRIVE STEEL FENCE POST AT LEAST 24" FENCE AND FABRIC INTO SOUD GROUND. BURIED IN TRENCH o CENTERLINE OF WATERLINE 2. WOOD POSTS ARE NOT ACCEPTABLE. 3. USE STAPLES 1' APART TO ATTACH East Carolina University COIR MESH BAFFLE (TYP.) y� FABRIC TO "HOG WIRE." 6"x6" TRENCH, CAST IRON METER O 4. BAFFLE SPACED AS PER APPROVED PLAN. BACKFILLED AND a O I BOX WITH DUAL F� 5. BAFFLE WALL BE COIR MESH OR SIMILAR, COMPACTED w d CHECK VALVE STAPLED OR TRENCHED INTO BOTTOM OF z < � School of Dental Medicine SEDIMENT PIT SIDE. w a SECTION AT OPENING ''II'' co SERVICE LINE CONNECTION Brunswick County N C EARTH BERM 5 �I 1 O CURB BY OTHERS STOP, TYP N WATER METER-SENSUS AMR/AMI, PER SPECS, OR APPROVED BY BRUNSWICK COUNTY ENGINEERING & q' n UTILITIES DEPARTMENT 3 CRUSHED STONE ASINEEDED (SEEON WYE WYEE BLOCK SUPPORT OR INLET ZONE WATER MAIN CORP. STOP � SURFACE AREA BETWEEEN POSTS TOP OF BAFFLE SHOULD BE PLAN VIEW} STONE AS NEEDED DATE: 07/02/2014 FIRST CHAMBER 6' HIGHER THAN THE BOTTOM SERVICE SADDLE 1" CTS POLY TUBING 2!IX OF SURFACE AREA OF THE SPILLWAY w, 200 PSI SDR 9 SERVICE LINE SCALE: As indicated SECOND CHAMBER 25X OF SURFACE AREA NOTE: EYP PROJECT NO.: 6013031.01 1) CONTRACTOR SHALL PLACE METER BOX IN NON-TRAFFIC AREA AT OUTLET ZONE LOCATION SPECIFIED BY BRUNSWICK COUNTY ENGINEERING DEPARTMENT. 15X OF SURFACE AREA 2) METERS SHALL BE SET BY CONTRACTOR 3 METER BOXES SHALL BE CST IRON WITH DUAL H} A CHECK VALVES. 4 1 2" D 2" METERS) 1 / AND ME RS WILL REQUIRE 2' CTS POLY TUBING. 11 2" AND2" M REQUIRE 5 METERS WILL E UI E A METER BOX LL Q E 0 SIZED ADEQUATELY PERSPECTIVE VIEW = TO HOUSE A 1 1 2" OR 2" SENSUS METER. BOT TOM OF BAFFLE IN / DESIGNED HOG WIRE ATTACHED TRENCH AND TRENCH S GNED BY: AWK TO POSTS WITH FILLED WITH SOIL HORIZONTAL METAL POST LENGTHS OF WIRE WIRED SECURELY TO COMPACTED DRAWN BY: VERTICAL POSTS 3/4" - 2" STANDARD WATER TAP BAFFLE INSTALLATION - STEP 1 BAFFLE INSTALLATION - STEP 2 INSTALLATION DETAIL W-7 CHECKED BY: RTF BAFFLE INSTALLATION N.T.S. 7 STANDARD WATER TAP INSTALLATION DETAIL N.T.S. 1 SCALE: 1" = 30' N SITE DETAILS C705 0 15 30 60 EYP Architecture & Engineering, PC 811 West Hargett Street YP / Raleigh, NC 27603 L=2.84 Tel: 919 833 8818 R=32.67 —� Fax: 919 833 6898 =10• eypae.com L=0.30 L=6.56 R=1.00 CONSULTANTS: R=4.00 15.69 Structural Engineering: s.3o k 90 Stewart Engineering, Inc. / ii 59"W k k N 7"50 N?1. 421 Fayetteville St., Suite 400 738 k X 52.3 ,�"a� > ' R=25.00 N, Raleigh, NC 27601 X Tel 919 380 8750 X k k k L's2 1 X k tQ ;f y,�gyp , ,� �/ " M M k k k k x k Jk k Fax: 919 380 8752 ,� , , Civil Engineering/ Landscape Architecture: k k c d k X k k X k �. k „� f y8,., ✓t'��a,°" Cole Jenest &Stone, pa k X k k X \^ 119 East Hargett Street, Suite 300 13 10"W k \ 7.27' Raleigh, NC 27601 S 9 6 48"W k k k x k k x X X X X k X X � � s k Tel: 919 645 5964 6.81' k k k k k k k X k k k k x k " k x � ..`` ;` Fax: 919 719 1819 k k .62 404 F C k k X k k k k k k k kkk Plumbing Mechanical Electical & Fire Protection:X 4. 0 k k k X k k k k kk EYP, Inc X k k k �'%1��;��°3 „� � 420-1-A The Parkway (\ •'� X k Greer, SC 29650 3.52 5'14'21"E Tel: 864 334 0997 ° � k L=48.04 Fax: R=25.00CARO _�/ SIB ��Nu���n►iq / `����c'F,`?�• &.STD p .. F ES S i o C J SEAL F: C� _ ' �C_^ X p :Zoe c-1o3 ;z _ 5 v TNCA9 vk WETLAND POND - GEOMETRY AT PERMANENT POOL 1" - 20' 3 '''�•...aidU o00 •F•� 'filli1111%%% 10/06/14 Z.5 x 4 FI E DEPARTMENT CONNECTION; ORIENT TO FACE DRIVEWAY FINISH GRADE TO SLOPE u' AWAY FROM COVER rn z MANHOLE ACCESS 0 N D 1 REVIEW COMMENTS 06111114 2 BID DOCUMENTS 07102114 3 ADDENDUM 1 07125114 PROVIDE SWING CHECK VALVE 4 REVIEW COMMENTS 07131114 WITH INTEGRAL BALL CHECK DRAIN 5 NCDENR EROSION CONTROL 10106114 STEPS @ 12" O.C. CENTERED UNDER MH '-' PRECAST CONCRETE VAULT Q 6 NCDENR STORMWATER 11114114 ACCESS APPROXIMATE INSIDE DIMENSION SW x 5'L x 4'D TO ACCOMODATE EQUIPMENT. CONTRACTOR TO SUBMIT SHOP DRAWINGS FOR APPROVAL FLOWT 0 ;EB3LDG 0 # Revision Date I CONCRETE SUPPORT SCO I D#• 07-07054-02J BLOCKING AS REQUIRED 6" IN—LINE CHECK VALVE SUMP DRAIN MIN 1 CF GRAVEL AT SUMP PRECAST CONCRETE VAULT FOR FDC N.T.S. 2 y, BAFFLE 110000 ,r ,«a TEMPORARY SKIMMER PLAN VIE1N 0a � SEDIMENT TRAP DESIGN y" 3rd BAFFLE: CRITERIA H NOTES: HARDWARE CLOTH DRAINAGE ` SURROUNDING 1. REFER TO NCESCPDM Community Service AREA < 10 AC. SKIMMER SECTION #6.60 FOR (ACRES) ' :"" ADDITIONAL DESIGN Learning Center #8 EMBANKMENT SPECIFICATIONS MIN. .: REGARDING LENGTH TO 2:1 . TEMPORARY SEDIMENT WIDTH RATIO INFLOW TRAPS. Brunswick STRUCTURE MIN. 1800 VOLUME (CU. FT. East Carolina University ' y REQUIRED PER AC. / � � , s- DISTURBED) School of Dental Medicine 325 � SKIMMER SURFACE (so. Fr. .� =4�e DEwATER1N AREA PER CFS Brunswick County NC REQUIRED $� 010) � x EMERGENCY AVERAGE= AREA* e �s.: '//////l SPILLWAY WIDTH W LENGTH % ;? * AREA OF BASIN WATER > SURFACE AT TOP OF PRIMARY SPILLWAY CROSS—SECTION VM 6" MAX. DEPTH OF FLOW 1' FREEBOARD W DATE: 0710212014 INFLOW OVER EMERGENCY SPILLWAY EMBANKMENT SCALE: As indicated STRUCTURE MIN. 1' T EYP PROJECT NO.: 6013031.01 MIN. DEWATERING ,,� ZONE EMERGENCY �r SPILLWAY (ONLY) SEDIMENT n.y , ., ,., �...» AS INDICATED DESIGNED BY: AWK STORAGE ZONE BAFFLE DRAWN BY: DATA BLOCK CHECKED BY: RTF TRAP N0. DRAINAGE DENUDED TRAP VOLUME TRAP SURFACE AREA CLEANOUT H L T W11 X (ACRES) (ACRES) Qio REQUIRED PROVIDED R QQUIRE PROVID9) DEPTH (FEET) (FEET) (FEET) (FEET) (FEET) (CUBIC FT.) (CUBIC FT.) �SQ FT.� (SQ FT. # 1 7.55 4.05 35 7,250 15,061 11,375 12,147 .75 2.5 N/A 1 1 1 10 7 TEMPORARY SKIMMER BASIN N.T.S. 1 SCALE: 1" = 30' N SITE DETAILS C706 0 15 30 60