Loading...
HomeMy WebLinkAboutWQ0000889_Monitoring - 10-2024_20241120Monitoring Report Submittal Permit Number#* Name of Facility:* Month: * October Report Information WQ0000889 PCS Phosphate Company Inc. Type * NDMR, NDAR-1, NDAR-2, NDMLR Confirmation Email Address: * Name of Submitter: * Signature: Date of submittal: Initial Review Year:* 2024 Upload Document* October2024 Nutrien 485.25KB N D M R_N DAR_WQ0000889. pdf PDF Only Please upload one PDF containing all applicable monitoring reports (i.e., NDMR, NDAR-1, NDAR-2, NDMLR, GW-59). deja.drummond@nutrien.com Deja Drummond ,iJ/rt �t«iirrrro�d 11 /20/2024 This will be filled in automatically Reviewer: Wanda.Gerald Is the project number correct?* WQ0000889 Is the monitoring report accepted?* Yes No Regional Office* Washington Reviewer: _anonymous Review Date: 11/21/2024 lutrien- CERTIFIED MAIL November 20, 2024 Division of Water Resources Non -Discharge Compliance / Enforcement Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Subject: Permit #WQ0000889 PCS Phosphate Company, Inc.l Wastewater Treatment Plant Monthly Report October 2024 Dear Mr. Bullock, Please find the attached digital copy of PCS Phosphate Company, Inc.'s Non -Discharge Monitoring Report (NDMR) and PCS Phosphate Company, Inc.'s Non -Discharge Application Report (NDAR-2), as required by condition IV.6 of the above referenced permit. Please do not hesitate to contact me at (252) 675-8883 if I can answer any questions or provide any additional information. Sincerely, Deja Drummond Environmental Engineer Nutrien — Aurora Attachments ec: 12-04-01 w/attach J.C. Stroud w/attach B. Curtis w/attach L. D. Davis w/attach 1530 NC Hwy 306 South, Aurora, NC USA 27806 nutrien.com 1 Effective January 1, 2018, PCS Phosphate Company, Inc. is an indirect subsidiary of Nutrien Ltd. PCS Phosphate Company, Inc. remains the legal operating entity and permittee. FORM: NDAR-2 05-16 NON -DISCHARGE APPLICATION REPORT (NDAR-2) Page _1_ of _2_ Permit No.: W00000889 Facility Name: PCS Phosphate WWTP County: Beaufort Month: October Year: 2024 Did infiltration occur at Site Name: 1 Site Name: 2 Site Name: 3 Site Name: this facility? Area (acres): 0.15 Area (acres): 0.15 Area (acres): 0.15 Area (acres): ❑� YES ❑ NO Rate (GPD/ft2): 4.99 Rate (GPD/ft): 4.99 Rate (GPD/ft): 4.99 Rate (GPD/ft): Weather Freeboard Site Infiltrated? YES ❑ No Site In ltrated?i Q YES ❑ NO Site Infiltrated? 2) YES ❑ No Site Infiltrated? ❑ YES ❑ NO N o i C o_ � e m °i c e p2 a° 21 O 2 E5 °T ° "aE a' Ea .QE1�0 4 smaY ° + U )i > C °° H= co CL - oa > o _U_ LL m J U. � JIL LL mv) °F in ft gal min GPD/fe ft gal min GPD/ft2 ft gal min GPD/ft2 ft gal min GPD/ft2 ft 1 CL 79 0 6,700 146 1.03 2 C 75 0 6,900 152 1.06 3 C 78 0 6,600 140 1.01 4 C 79 0 9,700 217 1.48 5 79 0 2,867 73 0.44 6 75 0 2,867 73 0.44 7 C 82 0 2,867 73 0.44 8 C 75 0 5,700 136 0.87 9 C 71 0 7,500 150 1.15 10 C 65 0 5,200 160 0.80 11 C 69 0 5,716 141 0.87 12 76 0 4,900 118 0.75 13 78 0 4,900 118 0.75 14 C 79 0.01 4,900 118 0.75 15 C 66 0 2,500 62 0.38 16 C 58 0 6,400 158 0.98 17 C 59 0.01 6,400 148 0.98 18 C 61 0 7,470 190 1.14 19 67 0 3,328 102 0.51 20 70 0 3,328 102 0.51 21 C 73 0 3,328 102 0.51 22 C 1 74 0 6,520 145 1.00 23 C 80 0 5,480 191 0.84 24 C 80 0 10,700 293 1.64 25 C 77 0 8,961 244 1.37 26 76 0 5,476 148 0.84 27 77 0 5,476 148 0.84 28 C 63 1.05 5,476 148 0.84 29 C 63 1 0 5,000 135 0.77 30 C 71 0 5,400 144 0.83 31 C 77 0 6,100 164 0.93 Monthly Loading (GPD/ft ): 0.83 1.14 0.81 #DIV/0! Year to Date Loading GPD/ft2 FORM: NDAR-2 05-16 NON -DISCHARGE APPLICATION REPORT (NDAR-2) Did the application rates exceed the limits in Attachment B of your permit? If not a basin, were the sites kept free of vegetation and raked? If not a basin, were there any instances of effluent ponding in or runoff from the sites? If a basin, were there any instances of breakout from the berms? Was the onsite automatically activated standby power source tested and operational? Page _2_ of _2_ ❑� Compliant ❑ Non -Compliant 2 Compliant ❑ Non -Compliant I] Compliant ❑ Non -Compliant ❑� Compliant ❑ Non -Compliant ❑� Compliant ❑ Non -Compliant If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective action(s) taken. Attach additional sheets if necessarv. Operator in Responsible Charge (ORC) Certification Permittee Certification ORC: Larry D Davis Jr. Permittee: PCS Phosphate Company, Inc. Certification No.: 1004832 Signing Official: William M. Ponton Grade: IV Phone Number: (252) 322-8111 ext. 8656 Signing Official's Title: General Manager Has the ORC changed since the previous NDAR-2? ❑ Yes El No Phone Number: (252)322-8283 Permit Exp.: 4/30/28 nature Date Signature Date By this signature, I certify that this report is accurrate and complete to the best of my knowledge. I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page _1_of_2_ Permit No.: W00000889 Facility Name: PCS PHOSPHATE WWTP County: Beaufort Month: October Year: 2024 PPI: 001 Flow Measuring Point: ❑ Influent ❑� Effluent ❑ No flow generated Parameter Monitoring Point: Influent ❑J Effluent ❑ Groundwater Lowering ❑ Surface Water Parameter Code ---► 50050 00310 00940 50060 31616 00610 00625 00620 00600 00400 00665 70300 00530 m Q ~ C m H CO 0 _b U. � m p tJ 3 C G ~ V ep Ct aLL1 C) C E Q m Y Z � m „R�,, Z p•� 0 O H Z 2 a .� C CL t- L a m N .A. 0 Q (n 1A �' y N 24-hr hrs GPD mg/L mg/L mg/L #1100 mL mg/L mg/L mg/L mg/L su mg/L mg/L mg/L 1 06:30 10.5 6,700 7.14 2 06:30 10.5 6,900 7.06 3 06:30 10.5 6,600 <2.0 <1 <0.20 <2.00 11.36 11.4 7.12 15.43 <2.5 4 06:30 10.5 9,700 7.06 5 2,867 6 2,867 7 06:30 10.5 2,867 6.85 8 06:30 10.5 5,700 7.1 9 06:30 10.5 7,500 7.19 10 06:30 10.5 5,200 7.07 11 06:30 10.5 5,716 7.15 12 4,900 13 4,900 14 06:30 10.5 4,900 7.2 15 06:30 10.5 2,500 7.21 16 06:30 10.5 6,400 7.18 17 06:30 10.5 6,400 7.02 18 06:30 10.5 7,470 7.06 19 3,328 20 3,328 21 06:30 10.5 3,328 7.1 22 06:30 10.5 6,520 7.09 23 06:30 10.5 5,480 7.32 24 06:30 10.5 10,700 7.15 25 06:30 10.5 8,961 1 1 7.3 261 5,476 271 5,476 281 06:30 10.5 5,476 7.11 29 06:30 10.5 5,000 7.21 30 06:30 10.5 5,400 7.15 31 06:30 10.5 6,100 7.3 Average: 5,634 0.00 1.00 0.00 0.00 11.36 11.40 15.43 0.00 Daily Maximum: 10,700 2.00 1.00 0.20 2.00 11.36 11.40 7.32 15.43 2.50 Daily Minimum: 2,500 2.00 1.00 0.20 2.00 11.36 11.40 6.85 15.43 2.50 Sampling Type: Recorder Composite Composite Grab Grab Composite Composite Composite Composite Grab Composite Composite Composite Monthly Avg. Limit: 10 200 4 5 Daily Limit: 30,000 15 6 (6-9) 10 Sample Frequency: Continuous Monthly 3x Year Per Event Monthly Monthly Monthly Monthly Monthly 5 x Week Monthly 3 x Year Monthly FORM: NDMR 03-12 NON -DISCHARGE MONITORING REPORT (NDMR) Page _2_ of _2_ Sampling Person(s) 11 Certified Laboratories Name: Larry D.Davis, Jr. Name: Waypoint Incorporated Id. 10 Name: Name: PCS Phosphate Inc. ID 330 Does all monitoring data and sampling frequencies meet the requirements in Attachment A of your permit? 0 Compliant ❑ Non -Compliant If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective action(s) taken. Attach additional sheets if nerescary Operator in Responsible Charge (ORC) Certification Permittee Certification ORC: Larry D. Davis, Jr. Permittee: PCS Phosphate Inc. Certification No.: 1004832 Signing Official: William M. Ponton Grade: IV Phone Number: 252-322-8111 ext 8656 Signing Officials Title: General Manager Has the ORC changed since the previous NDMR? ❑ Yes FZI No Phone Number: 252-322-8283 Permit Expiration: 4/30/2028 Jul- � y nature Date Signature Date By this signature, I certify that this report is accurrate and complete to the best of my knowledge. I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617