Loading...
HomeMy WebLinkAbout310467_Compliance Evaluation Inspection_20241031Facility Number © - QYDivision of Water Resources 0 Division of Soil and Water Conservation 0 Other Agency Type of Visit: &Compliance Inspection 0 Operation Review 0 Structure Evaluation 0 Technical Assistance Reason for Visit: @r1koutine 0 Complaint 0 Follow-up 0 Referral 0 Emergency 0 Other 0 Denied Access Date of Visit: D ?q Arrival Time::/ •DO Departure Time: I County: IIO Farm Name: � �� �AY mS Ifs— l.� V, K— S Owner Email: Owner Name: Mailing Address: Physical Address: Facility Contact: Title: Phone: Onsite Representative: (�& h!g Certified Operator: Back-up Operator: Location of Farm: Swine Latitude: Phone: Integrator: Region: Certification Number: g q 6 6 j L( Certification Number: Design Current Design Current Capacity Pop. Wet Poultry Capacity Pop. 2 22I 11-ayer Non -Layer Wean to Finish Wean to Feeder Feeder to Finish ITBO IgLkG Farrow to Wean Farrow to Feeder Farrow to Finish Gilts Boars Other Design Current Dry Poultry Canacitv Pon - Layers Non -Layers Pullets Turkeys Turkey Poults Other Discharges and Stream Impacts 1. Is any discharge observed from any part of the operation? Discharge originated at: ❑ Structure ❑ Application Field ❑ Other: a. Was the conveyance man-made? b. Did the discharge reach waters of the State? (If yes, notify DWR) c. What is the estimated volume that reached waters of the State (gallons)? Longitude: Design Current Cattle Capacity Pop. Dairy Cow Dairy Calf Dairy Heifer Dry Cow Non -Dairy Beef Stocker Beef Feeder Beef Brood Cow ❑ Yes try{ No ❑ NA ❑ NE ❑ Yes ❑ No ❑ Yes ❑ No ❑ NA ❑ NE ❑ NA ❑ NE d. Does the discharge bypass the waste management system? (If yes, notify DWR) ❑ Yes ,❑—/No ❑ NA ❑ NE 2. Is there evidence of a past discharge from any part of the operation? El Yes 117� No ❑ NA ❑ NE 3. Were there any observable adverse impacts or potential adverse impacts to the waters ❑ Yes g No ❑ NA ❑ NE of the State other than from a discharge? Page I of 3 511212020 Continued Facili Number: Date of Inspection: Waste Collection & Treatment 4. Is storage capacity (structural plus storm storage plus heavy rainfall) less than adequate? ❑ Yes 9No ❑ NA ❑ NE a. If yes, is waste level into the structural freeboard? ❑ Yes ❑ No ❑ NA ❑ NE Structure I Structure 2 Structure 3 Structure 4 Structure 5 Structure 6 Identifier: �_ 2 Spillway?: Designed Freeboard (in): Ict. 5 a • 5 Observed Freeboard (in): :3 �— 3 5. Are there any immediate threats to the integrity of any of the structures observed? ❑ Yes � No ❑ NA ❑ NE (i.e., large trees, severe erosion, seepage, etc.) 6. Are there structures on -site which are not properly addressed and/or managed through a ❑ Yes WNo ❑ NA ❑ NE waste management or closure plan? If any of questions 4-6 were answered yes, and the situation poses an immediate public health or environmental threat, notify DWR 7. Do any of the structures need maintenance or improvement? Ui Yes ❑ No ❑ NA ❑ NE 8. Do any of the structures lack adequate markers as required by the permit? ❑ Yes L'No ❑ NA ❑ NE (not applicable to roofed pits, dry stacks, and/or wet stacks) 9. Does any part of the waste management system other than the waste structures require ❑ Yes No ❑ NA ❑ NE maintenance or improvement? Waste Application 10. Are there any required buffers, setbacks, or compliance alternatives that need ❑ Yes O No ❑ NA ❑ NE maintenance or improvement? 11. Is there evidence of incorrect land application? If yes, check the appropriate box below. ❑ Yes d�W No ❑ NA ❑ NE ❑ Excessive Ponding ❑ Hydraulic Overload ❑ Frozen Ground ❑ Heavy Metals (Cu, Zn, etc.) ❑ PAN ❑ PAN > 10% or 10 lbs. ❑ Total Phosphorus ❑ Failure to Incorporate Manure/Sludge into Bare Soil ❑ Outside of Acceptable Crop Window ❑ Evidence of Wind Drift ❑ Application Outside of Approved Area 12. Crop Type(s): 13. Soil Type(s): 14. Do the receiving crops differ from those designated in the CAWMP? ❑ Yes g No ❑ NA ❑ NE 15. Does the receiving crop and/or land application site need improvement? ❑ Yes ®No. ❑ NA ❑ NE 16, Did the facility fail to secure and/or operate per the irrigation design or wettable ❑ Yes [4 No ❑ NA ❑ NE acres determination? 17. Does the facility lack adequate acreage for land application? ❑ Yes 5j No `E� ❑ NA ❑ NE 18. Is there a lack of properly operating waste application equipment? ❑ Yes No ❑ NA ❑ NE Required Records & Documents 19. Did the facility fail to have the Certificate of Coverage & Permit readily available? ❑ Yes Ef No ❑ NA ❑ NE 20. Does the facility fail to have all components of the CAWMP readily available? If yes, check ❑ Yes R No ❑ NA ❑ NE the appropriate box. ❑ WUP ❑Checklists ❑ Design ❑ Maps ❑ Lease Agreements ❑Other: 21. Does record keeping need improvement? If yes, check the appropriate box below. ❑ Yes ❑ No ❑ NA ❑ NE ❑ Waste Application ❑ Weekly Freeboard ❑ Waste Analysis ❑ Soil Analysis ❑ Waste Transfers ❑ Weather Code ❑ Rainfall ❑Stocking ❑ Crop Yield ❑ 120 Minute Inspections ❑ Monthly and V Rainfall Inspections ❑ Sludge Survey 22. Did the facility fail to install and maintain a rain gauge? ❑ Yes 0 No ❑ NA ❑ NE 23. If selected, did the facility fail to install and maintain rainbreakers on irrigation equipment? ❑ Yes ENo ❑ NA ❑ NE Page 2 of 3 511212020 Continued Facility Number: Date of Inspection: tJ Q 24. Did the facility fail to calibrate waste application equipment as required by the permit? ❑ Yes allo ❑ NA ❑ NE 25. Is the facility out of compliance with permit conditions related to sludge? If yes, check ❑ Yes � No ❑ NA ❑ NE the appropriate box(es) below. ❑ Failure to complete annual sludge survey [:]Failure to develop a PDA for sludge levels ❑ Non -compliant sludge levels in any lagoon List structure(s) and date of first survey indicating non-compliance: 26. Did the facility fail to provide documentation of an actively certified operator in charge? ❑ Yes JXNo ❑ NA ❑ NE 27. Did the facility fail to secure a phosphorus loss assessments (PLAT) certification? ❑ Yes ❑ No U'NA ❑ NE Other Issues 28. Did the facility fail to properly dispose of dead animals with 24 hours and/or document ❑ Yes V] No ❑ NA ❑ NE and report mortality rates that were higher than normal? 29. At the time of the inspection did the facility pose an odor or air quality concern? If yes, contact a regional Air Quality representative immediately. 30. Did the facility fail to notify the Regional Office of emergency situations as required by the permit? (i.e., discharge, freeboard problems, over -application) 31. Do subsurface tile drains exist at the facility? If yes, check the appropriate box below. ❑ Application Field ❑ Lagoon/Storage Pond ❑ Other: 32. Were any additional problems noted which cause non-compliance of the permit or CAWMP? 33. Did the Reviewer/Inspector fail to discuss review/inspection with an on -site representative? 34. Does the facility require a follow-up visit by the same agency? ter to question #): Explain any YES answers and/or any addii of facility to better explain situations (use additional pages as S ud� of ZP) 7j- �iyh Z1Z1zz's boa 5j ofis Reviewer/Inspector Name: ❑ Yes M No ❑ NA ❑ NE ❑ Yes 19 No ❑ NA ❑ NE ❑ Yes a No ❑ NA ❑ NE ❑ Yes �) No ❑ Yes No ❑ Yes No or any 4 I nKw kloov) Wa Ns Reviewer/Inspector Signature:� Page 3 of 3 ❑NA ❑NE ❑ NA ❑ NE ❑ NA ❑ NE comments. Phone: 1 6 W Date: b Z 511212020