Loading...
HomeMy WebLinkAboutWQ0044684_WQ0044684 Application_20240917DIEHL & PHILLIPS, P.A. CnN51 I I ING I NONI I RS 1500 PmeN Plains Road Suite 200 Can. North Canolina 27518 elephone (919) 467-9972 Water Quality Section Raleigh Regional Office NC DEQ 3800 Barrett Drive Raleigh, NC 27609 September 16, 2024 NC Dept of E;l umil«ntal Qualit,; SEP 17 2024 Raleigh Reeional {office WII I ]AM C. DU III . 111 JOIN I I'IIII I HIS. P 1 Re: Request for Permit Modification Gravity Sewer Extensions to serve Section X Area F Fearrington P.U.D. Chatham County WQ 0044684 Dear Reviewer: Enclosed for your review are the following for the referenced project: I. Revised Plans for WQ 0044684 2. Copy of WQ 0044684 3. Copy of FTA & FTSE for Modification 4. Map & Quad Sheet 5. $600.00 Review Fee Al ANR.K11111.1'.1. We request that you approve the proposed permit modification. The gravity sewer was shortened from the original approved length (now 590 LF vs. 930 LF). The alignment of the proposed sewer does not vary from the approved plans. The number of lots proposed has decreased from 7 lots to 6 lots. The flow associated with the project is now 1,500 gallons per day. Should you have questions or require further information, please contact our office. Sincerely, Diehl & Phillips, P.A. Alan R. Keith, P.E. Cc: Greg Fitch State of North Carolina Department of Environmental Quality DWR Division of Water Resources P. &T TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 10-23 & SUPPORTING DOCUMENTATION kalclgL IZE.wonai t3ic'. Application Nurnber:N aO O"6 .4 (ai N. completed hN DW Ri All item I. APPLICANT INFORMATION: I . Applicant's name: Fearrinzton Utilities,I-LC (company, municipality, HOA, utility, etc.) 7. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ® Privately -Own Public Utility ❑ Federal ❑ State County ❑ Municipal ❑ Other �� 3. Signature authority's name: Greg Fitch per I5A NCAC 02T .0I06tb) �J J0 Title: Manager 4. Applicant's mailing address: 2000 Fearrington Village Center City: Pittsboro State: NC Zip: 27312- 5. Applicant's contact information: Phone number: (919) 542-4000 Email Address: greg,0fearrin_ on.com II. PROJECT INFORMATION: . Project name: Fearrinaton Section X Area G - Guilford 2. Application Project status: ❑ New Proposed Permit p ( ) ®Existing Permit Project If a modification, provide the existing permit number: WQ0044684 and issued date: 10 4 23. For modifications, also attach a detailed narrative description as described in Item G of the checklist. If new construction, but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Chatham / 4. Approximate Coordinates (Decimal Degrees): Latitude: 35..7929 Longitude:-79..0874 ./ 5. Parcel [D (if applicable): 18998 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: / 1. Professional Engineer: Alan R. Keith License Number: 11371 1/ Firm: Diehl & Phillips, P.A. Mailing address: 1500 Piney Plains Road Suite 200 City: Cary State: NC Zip: 27518- Phone number: (919) 467-9972 Email Address: arkeithR(bellsouth.net IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Fearrinzton W WTP Permit Number: NCO043559 Owner Name: Fearrin_t�tilities, LLC / V. RECEIVING DOWNSTREAM SEWER INFORMATION: I. Permit Number(s): WQQ043183 2. Downstream (Receiving) Sewer Information: 8 inch X Gravity Force Main 3. System Wide Collection System Permit Number(s) (if applicable): WQCS00238 Owner Name(s): Fearrim,ton Utilities, LLC FORM: FTA 10-23 Page I of 5 V1. GENERAL REQUIREMENTS I . If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ®Yes ❑No DNA 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DLV) been attached? ❑Yes ❑No ®NA 3. If the Applicant is a Home Property Owners' Association, has an HOA POA Operational Agreement (FORM_ FJOA) and supplementary documentation as required by 15A NCAC 02T.01 15(c) been attached? ❑Yes ❑No ®NA 4. Origin of wastewater: (check all that apply): ® Residential (Individually Owned) ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential (Leased) ❑ Retail with food preparation service ❑ Hotel and, or Motels ❑ School preschool day care ❑ Medical dental veterinary facilities ❑ Swimming Pool Clubhouse ❑ Food and drink facilities El Church ❑ Swimming Pool Filter Backwash ❑ Businesses offices factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: 100 ° o Domestic °o Commercial ° o Industrial (See 15A NCAC 02T .0I03(20j) If Industrial, is there a Pretreatment Program in effect? ❑ Yes❑ No 6. Has a flow reduction been approved under 15A NCAC 02T .01 14(t)? ® Yes ❑ No 1W If yes, provide a copy of flow reduction approval letter with this application otV 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(f)) Daily Design Flow " No. of Units Flow 250 gal/lot all 2 and 3 bedroom units 6 1500 GPD gal/ GPD gal/ GPD gal/ GPD gall GPD gal/ GPD Total 1500 GPD ./ See 15A NCAC 02T .01 14(bl, (_dl (eX1) and (e)(2) for caveats to wastewater design Flow rates (i.e. proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A_4). Per 15A NCAC 02T .01 14(c), design Flow rates for establishments not identified [in table 15A NCAC 02T.01 14] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 1500 GPD (per I SA NCAC 02T .01 Id and G.S. 143-215.1) .01 Do not include future flows or previously permitted allocations 69, If permitted flow is zero, please indicate why: ❑ Pump Station Force Main or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line. Please provide supplementary information indicating the approximate timeframe for permitting upstream sewers with flow. ❑ Flow has already been allocated in Permit Number: Issuance Date: ❑ Rehabilitation or replacement of existing sewers with no new flow expected ❑ Other (Explain): FORM: FTA 10-23 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gra%ith Sewers): I . Summarize gravity sewer to be permitted: T Size (inches) Length (feet) Material Section It & [if of the MDC for Permitting of Gravity Sewers contains information related to design criteria Section III contains information related to minimum slopes for gravity sewer(s) Oversizing lines to meet minimum slope requirements is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations;'Force Mains): PROVIDE A SEPARATE COPY OF THIS PAGE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - 3. Total number of pumps at the pump station: 3. Design flow of the pump station _ millions gallons per day (firm capacity) P, This should reflect the total GPM for the pump station with the largest pump out of service. 4. Operational point(s) per pump(s): gallons per minute (GPM) at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material If any portion of the force main is less than 4-inches in diameter, please identify the method of solids reduction per MDCPSFM Section 2.01 C. I .b. ❑ Grinder Pump ❑ Mechanical Bar Screen ❑ Other (please specify) 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or ❑ Standby pump Must have automatic activation and telemetry - 15A NCAC 02T.0305(h)(1)(B): Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day Must be permanent to facility and may not be portable Or if the pump station has an average daily flow less than 15,000 gallons per day 15A NCACO2T.0305(h)( l)(C): ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - or ❑ Portable pumping unit with plugged emergency pump connection and telemetry: Include documentation that the portable source is owned or contracted by the applicant and is compatible with the station. f the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided as part of this permit application in the case of a multiple station power outage. FORM: FTA 10-23 Page 3 of 5 IX. SETBACKS & SEPARATIONS - (02B .0200 & 15A NCAC 02T .0305(f)): f Does the project comply with all separations alternatives found in 15A NCAC 021 .03050) & W? ® Yes [:]No 15A NCAC 02T.0305(t) contains minimum separations that shall be provided for sewer systems: Setback Parameter I Separation Required Storm sewers and other utilities not listed below (vertical) 18 inches 'Water mains (vertical - water over server preferred, including in benched trenches) 18 inches -'Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet "Any private or public water supply source, including any wells, WS-1 waters of Class I or Class 11 impounded reservoirs used as a source of drinking water, and associated wetlands. 100 feet "Waters classified WS (except WS-1 or WS-V). B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands associated with these waters (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches, as well as wetlands associated with these waters or classified as WL. 10 feet Any building foundation (horizontal) 5 feet Any basement (horizontal) 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches If noncompliance with 02T.0305(t) or fgh see Section X.1 of this application * I SA NCAC 02T,0305(0 contains alternatives where separations in 02T.0305(t) cannot be achieved. Please check above if these alternatives are used and provide narrative information to explain. **Stream classifications can be identified using the Division's NC Surface Water Classifications webpage 2. Does this project comply with the minimum separation requirements for water mains? ® Yes ❑ No ❑ N A If no, please refer to 15A NCAC I8C.0906(t) for documentation requirements and submit a separate document, signed sealed by an NC licensed PE, verifying the criteria outlined in that Rule. / 3. Does the project comply with separation requirements for wetlands? ® Yes ❑ No ❑ N A Please provide supplementary information identifying the areas of non-conformance. See the Division's draft separation requirements for situations where separation cannot be met. No variance is required if the alternative design criteria specified is utilized in design and construction. 4. Is the project located in a river basin subject to any State buffer rules? ® Yes Basin name: Cape Fear ❑ No If yes, does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ® Yes ❑ No This includes Trout Buffered Streams per 15ANCAC 2B.0202 5. Does the project require coverage authorization under a 404 Nationwide individual permits ❑ Yes ® No or 401 Water Quality Certifications? P, Please provide the permit number permitting status in the cover letter if coverage authorization is required. 6. Does project comply with 15A NCAC 02 r.0105(ex6) (additional permits certifications)? ® Yes ❑ No Per 15A NCAC 02T.01051c)(6), directly related environmental permits or certification applications must be being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). Does this project include any sewer collection lines that are deemed "high -priority?" ® Yes [:]No Per 15A NCAC 02 f.0402, "high -priority sewer" means any aerial sewer, sewer contacting surface waters, siphon, or sewers positioned parallel to streambanks that are subject to erosion that undermines or deteriorates the sewer. Siphons and sewers suspended through interference/conflict boxes require a variance approval. P, If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permtttee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permittee's individual System -Wide Collection permit. FORM: FTA 10-23 Page 4 of 5 X. CERTIFICATIONS: I Dues the submitted system comply with _ , the %Jninnum I►"ap �_'rrli.'rs% for the F'crill nun. "; Puna N%r rn�i F.,r'e �Lun. Li{_a %er.i„� and the antic. �c�, tr �tmmt�ui [k>i �t t nt:rt.i r latc_t _cr:um i as applicaMc^ ® Yes ❑ Nu If no, Cur projects requiring a single variance, complete and submit the Vanance.'Alternative Design Request application (VADC 10-14) grid supporting documents for review to the Central Office .Approval of the request will bg issued concurrently with the approval of the permit, and projects requiring a variance approval may be subject to longer review times. For projects requiring two or more variances or where the variance is determined by the Division to be a significant portion of the project, the full technical re% ieK is required. 2 Professional Engineer's Certification. 1, Alan R Keith attest that this application for Fearrington Section _X Area F (Professional 6girxix's name from Application Item M. I I (Project Nune from Applrerian Item II 1) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. t Ptuther attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Minimum Design Crit_eria_t'orGraviI% Sewer, (latesr v4r%ion►, and the Minimum Desten Cnirria lorihe -I rack Per mains of Pump Stations and Force Mains 1latest version) Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seat signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.68, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to S25,000 per violation. Misrepresentation of the application information, including failure to disclose any design non-compliance with the applicable Rules and design criteria, may subject the North Carolina -licensed Professional Engineer to referral to the licensing board. (21 NCAC 56.0701) North Carolina Professional Engineer's stal, signature, and date:\\���l � ORAL 13=i1 19 Or 3. Applicant's Certification per 15A NCAC 02T.0106(b): 9/11At i, Greg Fitch attest that this application for Fearrington Section X Area F (Sigiumic Audiodry Name from Appl Ica6on Item 1.3) (Project Namc fnxn Application Item II 1) attest that this application has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non -discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should it condition of this permit be violated- 1 also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete NOTE in accordance with General Statutes 143 ? 15.6A and 143-215.613 any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed S 10,000 as well as civil penalties up to $25,000 per violation. Signature: Date: FORM: FTA 10-23 Page 5 of 5 NC 0CPIot Crvir0i,,,,e:lial Quaiiiy State of North Carolina Department of Environmental Quality Division of Water Resources Ra 1 el4i&W94P94cepta nee for Sewer Extension Applications (FTSE 04-16) Entity Requesting Allocation: Fearrington utilities, LLC J Project Name for which flow is being requested: Fearrington Section X Area F More than one FTSE niay be required for a single project if the owner of the ;VWTP is not responsible for all pump stations along the route of the proposed wastewater flow 1. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Fearfington WWTP b. WWTP Facility Permit M NCO043559 c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used A11 flows are in MGD _0.50 (0.270 constructed) 0.05615 0.150 0.00150 0.2077 77.00 11. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E) (A-D) Design Obligated, A� erage Daily Approx. Not Yet Total Current Pump Station Firm Flow** Current Tributary Flow Plus (Name or Capacity. * (Firm pf). Avg Daily Daily Flow. Obligated Available Number) MGD MGD Flow, MGD MGD Flow Capacity*** Weathersfield 0.90 0.36 0.14 0.019 0.155 0.205 * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pi) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacih is < 0. Downstream Facility Name (Sewer): Fearrin on Section X Area F ✓ Downstream Permit Number: W 0036339 Page 1 of 6 Ill. Certification Statement: I Greg Pitch _ _ certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form indicates acceptance of this wastewater flow. Signing Official Signature Date Page 2 of 6 FTS)✓ 04-16 ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS, JR. Director NORTH CAROLINA Environmental Quality October 4, 2023 Greg Fitch, Manager Email: grel;@fearrinl;ton.com Fearrington Utilities, LLC 2000 Fearrington Village Center Pittsboro, NC 27312 Subject: Permit No. WQ0044684 Fearrington Utilities, LLC Fearrington Section X Area F Wastewater Collection System Extension Permit Chatham County Dear Mr. Fitch: ANC Dept of Erviro;,,-,;e;1,,a1 Quality Raleigh Regional office In accordance with your application received August 21, 2023, and additional information received on October 4, 2023, we are forwarding herewith Permit No. WQ0044684 dated October 4, 2023, to Fearrington Utilities, LLC (Permittee) for the construction and operation upon certification of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to the following conditions contained within this permit: Condition 11.1: This permit shall not be automatically transferable; a request must be made and approved. Condition 11.7: Upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form with checklist attached to this permit shall be submitted with the required supporting documents to the address provided on the form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations, or the Minimum Design Criteria. (15A NCAC 02T.01161 It shall be responsibility of the Permittee to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This D,�� � Vorth Caotiaa Dreatn�c i of Eatzrormefltal Q>pl« Dn�inn oftl,'eter Reeonrce� Rde b Regonel c&ce 3900 B=ett Dnve Me* NottL Caolms 2"6 )9 w �\ 0g.I 919 "91 4: M7 NORTH CAROLINA Environmental Quality WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT in accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the Fearrington Utilities, LLC Chatham County for the construction and operation of approximately a3D-inear feet of 8-inch gravity sewer to serve, three -bedroom homes as part of the Fearrington Section X Area F project, and the discharge of 1,750* gallons per day of co lected domestic wastewater into the Fearrington Utilities' existing sewerage system, pursuant to the application received August 21, 2023, and additional information received on October 4, 2023, and in conformity with 15A NCAC 02T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 and updated in March 2008, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting data subsequently filed and approved by the Department of Environmental Quality and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded and shall be subject to the specified conditions and limitations contained therein. *Via letter sent on April 27, 2007, DWR granted Fearrington Utilities an adjusted daily sewage design flow rate of 250 gallons per day per one to three bedroom single family dwelling, with an additional 70 gallons per day per each bedroom over three bedrooms. l'DocuSgnedby C f , h A. VAlII t.SSQ B2918EBAB3214AF for Richard E. Rogers, Jr. Director, Division of Water Resources By Authority of The Environmental Management Commission Permit Number: WQ0044684 Permit Issued: October 4, 2023 Page 3 of 9 operation and maintenance of these facilities as required by 1SA NCAC 02T .0403. If an individual permit is not required, the following performance criteria shall be met: a. The sewer system shall be effect vely maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 36S days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High priority sewer lines shall be inspected at least once per every six -months and inspections are documented. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143.215.1C. h. A Grease Control Program is in place as follows: 1. For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. 2. For privately owned collection systems, the Grease Control Program shall include at least bi- annual distribution of grease education materials to users of the collection system by the permittee or its representative. 3. Grease education materials shall be distributed more often than required in Parts (1) and (2) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows. i. Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility. j. Documentation shall be kept for Subparagraphs (a) through (i) of this Rule for a minimum of three years with exception of the map, which shall be maintained for the life of the system. 5. The Permittee shall report by telephone to a water resources staff member at the Paleiph Regional Office, telephone number (919) 791-4200, as soon as possible, but in no case more than 24 hours, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any SSO and/or spill over 1,000 gallons; or c. Any SSO and/or spill, regardless of volume, that reaches surface water Page 5 of 9 construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation. [15A NCAC 02T .0116] 8. Gravity sewers installed greater than ten percent below the minimum required slope per the Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified unti; corrected. if there is an unforeseen obstacle in the field where all viable solutions have been examined, a slope variance can be requested from the Division with firm supporting documentation. This shall be done through a permit modification with fee. Such variance requests will be evaluated on a case -by case bass. Resolution of such request shall be evident prior to completing and submitting the construction certification. [ 15A NCAC 02T.0105(n)] 9. A copy of the individual permit and construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. [15A NCAC 02T .0116] 10. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 02T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143-215.6A through §143- 215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. [15A NCAC 02T .0108(b-c)] 11. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. [15A NCAC 02T .0110; 15A NCAC 02T .0108(b)] 12. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by the Division any other Federal, State, or Local government agencies which have jurisdiction or obtaining other permits which may be required by the Division or any other Federal, State, of Local government agencies. [G.S. 143-215.1(b)] Page 7 of 9 � o o " WFATHf� o ORRIS R4 'Am M VILLAGEVAY V D KENT �� 3 m Fearrington ono FqT � Village /y 41AL CROSSI. h� F'QSF� A 4ED7RIBUTARY1 p f�D TO BUsFi cRrrlc V � • / EYISTINC CRA 1 ITY 41 .� FUTURE FEARRINGTON > tu'i IBC: �o�� ' u[H SECTION X AREA G 'A EArF\ uX-6, lkid). ri r n E\!Sf[VC -NREA D FUTURF ARFA F GRA VITY',ER ER �7 1vQW41684 QG BARRUS C LU ��tiRD = 450 BIG HOLE RD O� LAUREL KNOLL DR �i. GRAPHIC SCALE ION 0 500 1000 2000 FEARRINGTON.SUBDIVISION DIEHL & PHILLI —5 P.A. I,SGti t,)L;tf).l1.IP _MILL I ING. L\!.I\I:LIt4 LIC.\[1.C.41.: 1 11�R.I,vn,•-"7 C71.1fF1:1.NCOC.bt7,.VOXTfICAR01.7.\A C. \Mut�.\C `17aa.+•mlx.'�wn w� 00 � I '�•. -off � 7r . � � �' •',� - :'ti"' 00 WISWAX LS 1 *4i�h.t1 ✓►� a �,r y. .`. ` f '►-ice � H..� y. 'a ;S �� r�.. a, ate` . 1 .• tip �. ��+�f�. .'rs `fir •A-;c .:'�, , .a;����`�•+ rq 7;. � �•�!L�.�`�t '� v1 •`• « �R�t .Pr�� ..\ o, Al ` q tr ray y^. i JIB � .�� .•tom M •` y ` t4 ♦ � l :i 4T^. 1 r •t,C � r 1' > " PPPP ���' ri'r+ 'an. 'fe4ti'� =' � 7:v �.. . � ; .' ' >♦�P ' �e f" ��}rf� . i'T "bl� tit.• ��1[��' �a I� , v �+ 11C+C1 ti w 31[UP It AqJ .ems. '�`' ... e' j•�9�'', �ae� !f �7 � .� � ` �.`. Jr fi < i Vets •: J:, � -.'.,' + y�r�,„, r . • '` fir"�;:..;..� '�" •^ , t�A \,tad .��p!�'.;'r'�M, - ({yyi1,; . J t �+ R,, �y�%:�'.L'~'i.?�; yj?'�•: �'g`_;. i "' t /i} - �S'�; �! '+'�'` ' �y'"•'�4'��V= ��y�"'y„� , • �✓�{�" 1 l;'Y.. %f•�4Y ,�ityZ•'+i - 1-' — State of North Carolina C Dept of ErtvDWR irorimental Qualm, Department of Environmental Quality Division of Water Resources FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources INSTRU9TIONS FOR FORM: FTA 10-23 & SUPPORTING DOCUMENTATION This application is for sewer extensions fnvo tl -grh�1 rs, pump stations and force mains, or any combination that has been certified by a professional engineer and the applicant that the project meets the requirements of 15A NCAC 021 and the Division's Minimum Design Criteria (Gravit% Se,.%er & Punk Stations Ford' lains) and that plans, specifications and supporting documents have been prepared in accordance with 15A NCAC 02T, 15A NCAC 02T .0300, Division policies, and good engineering practices. While no upfront engineering design documents are required for submittal, in accordance with 15A NCAC 02T .0305(b), design documents must be prepared prior to submittal of a fast track permit application to the Division. This would include plans, design caicuiations, and project specifications referenced in 15A NCAC 02T .0305 and the applicable minimum design criteria. These documents shall be immediately available upon request by the Division. Projects that are deemed permitted (do not require a permit from the Division) are explained in 15A NCAC 02T.0303. Projects not eligible for review via the fast track process (must be submitted for full technical review): Projects that do not meet any part of the minimum design criteria (MDC) documents; Projects that involve more than one variance from the requirements of 15A NCAC 02T; Pressure sewer systems utilizing simplex septic tank -effluent pumps (STEPS) or simplex grinder pumps; Simplex STEP or simplex grinder pumps connecting to pressurized systems (e.g. force mains); Vacuum sewer systems. General When submitting an application, please use the following instructions as a checklist in order to ensure all required items are submitted. Adherence to these instructions and checking the provided boxes will help produce a quicker review time and reduce the amount of requested additional information, Failure to submit all required items will necessitate additional processing and review time, and may result in return of the application. Unless otherwise noted, the Applicant shall submit one original and one copy of the application and supporting documentation. A. One Original and One Copy (second copy may be digital) of Application and Supporting Documents E Required unless otherwise noted. Signatures on original must be "wet ink" or secure digital signatures. Please do not submit engineering design plans with the application unless specifically requested. B. Cover Letter/Narrative Description (Required for All Application Packages): E List all items included in the application package, as well as a brief description of the requested permitting action. Be specific as to the system type, number of homes served, flow allocation required, etc. Include the permit number status of any other required sewer permits (downstream upstream) If necessary for clarity, include attachments to the application form. C. Application Fee (All New and Modification Application Packages): E Submit a check or money order in the amount of $600.00, dated no more than 90 days prior to application submittal. J� Payable to North Carolina Department of Environmental Quality (NCDEQ) D. Fast Track Application (Required for All Application Packages, Form FTA 10-23): E Submit the completed and appropriately executed application. .- If necessary for clarity or due to space restrictions, attachments to the application may be made. Q If the Applicant Type in Item 1.2 is a corporation or company, provide documentation it is registered for business with the North Carolina Secretary of State. ❑ If the Applicant Type in Item 1.2 is a partnership or d b a, enclose a copy of the certificate filed with the Register of Deeds in the county of business. E The Project Name in Item 11.1 shall be consistent with the project name on the flow acceptance letters, agreements, etc. E The Professional Engineer's Certification on Page 5 of the application shall be signed, sealed and dated by a North Carolina licensed Professional Engineer. E The Applicant's Certification on Page 5 of the application shall be signed in accordance with 15A NCAC 02T .0106(b). Per 15A NCAC 02T .0106(c), an alternate person may be designated as the signing official if a delegation letter is provided from a person who meets the criteria in 15A NCAC 02T .0106(b). INSTRUCTIONS FOR FORM: FTA 10-23 & SUPPORTING DOCUMENTATION Pagel of 3 E. Flow Tracking/Acceptance Form (Form: FTSE 10-23) (If Applicable): ® Submit the completed and executed FTSE form from the owners of the downstream sewers and treatment facility. Multiple forms maybe required where the downstream sewer owner and wastewater treatment facility are different. The Flow acceptance indicated in form FTSE must not expire prior to permit issuance and must be dated less than one year prior to the application date. Submittal of this application and form FTSE indicates that owner has adequate capacity and will not violate G.S. l d3-215.67(a). Inter_;overnmentai agreements or other contracts will not be accepted in lieu of a project -specific FTSE. F. Site Maps (All Application Packages): ® Submit an 8.5-inch x I I -inch color copy of a USGS Topographic Map of sufficient scale to identify the entire project area, including the closest surface waters 10, General location of the project components (gravity sewer, pump stations, & force main) 1� Downstream connection points and permit number (if known) for the receiving sewer ® Include an aerial location map showing general project area (such as street names or latitude longitude) so that Division staff can easily locate it in the field. G. Existing Permit (Application Packages for Modifications to an Existing Permit): ® Submit a copy of the most recently 'issued existing permit. ❑ Include a descriptive and clear narrative identifying the previously permitted items to remain in the permit, items to be added, and/or items to be modified (the application form itself should include only include items to be added modified). The narrative should also include whether any previously permitted items have been certified. The narrative should clearly identify the requested permitting action and accurately describe the sewers to be listed in the final permit. H. Power Reliability Plan (Required if portable reliability option utilized for Pump Station): ❑ Per 15A NCAC 02T .0305(h)( l ), submit documentation of power reliability for pumping stations. This alternative is only available for average daily flows less than 15,000 gallons per day It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant and is compatible with the station. The Division will accept a letter signed by the applicant (see 15A NCAC 02T .0106(b)) or proposed contractor, stating that "the portable power generation unit or portable, independently -powered pumping units, associated appurtenances and personnel are available for distribution and operation of this pump station." If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. (Required at time of certification) I. Certificate of Public Convenience and Necessity (All Application Packages for Privately -Owned Public Utilities): ® Per 15A NCAC 02T .01 15(a)( 1) provide the Certificate of Public Convenience and Necessity from the North Carolina Utilities Commission demonstrating the Applicant is authorized to hold the utility franchise for the area to be served by the sewer extension, or ❑ Provide a letter from the North Carolina Utilities Commission's Water and Sewer Division Public Staff stating an application for a franchise has been received and that the service area is contiguous to an existing franchised area or that franchise approval is expected. J. Operational Agreements (Applications from HOA/POA and Developers for lots to be sold): O Home Property Owners' Associations ❑ Per 15A NCAC 02T .01 15(c), submit the properly executed Operational Agreement (FORM: HOA). ❑ Per 15A NCAC 02T .0l 15(c), submit a copy of the Articles of Incorporation, Declarations and By-laws. ❑ Developers of lots to be sold ❑ Per 15A NCAC 02T .01 15(b), submit the properly executed Operational Agreement ( FORM: DEV). For more information. visit the Division's collection st,steins nrebsite INSTRUCTIONS FOR FORM: FTA 10-23 & SUPPORTING DOCUMENTATION Page 2 of3 THE COMPLETED APPLICATION PACKAGE INCLDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE: REGIONAL OFFICE Asheville Regional Office Water Quality Section Fayetteville Regional Office Water Quality Section Mooresville Regional Office Water Quality Section Raleigh Regional Office Water Quality Section Washington Regional Office Water Quality Section Wilmington Regional Office Water Quality Section PU15104*1 2090 US Highway 70 Avery, Buncombe, Burke, Caldwell, Cherokee, Swannanoa, North Carolina 28778-8211 Clay, Graham, Haywood, Henderson, Jackson, (828) 296-4500 Macon, Madison, McDowell, Mitchell, Polk, (828) 299-7043 Fax Rutherford, Swain, Transylvania, Yancey 225 Green Street Suite 714 Anson, Bladen, Cumberland, Harnett, Hoke, Fayetteville, North Carolina 28301-5095 Montgomery, Moore, Robeson, Richmond, (910) 433-3300 Sampson, Scotland (910) 486-0707 Fax 610 E. Center Avenue Mooresville, North Carolina 28115 (704)663-1699 (704) 663-6040 Fax 3800 Barrett Drive Raleigh, North Carolina 27609 (919) 791-4200 (919) 571-4718 Fax 943 Washington Square Mall Washington, North Carolina 27889 (252) 946-6481 (252) 975-3716 Fax 127 Cardinal Drive Extension Wilmington, North Carolina 28405 (910) 796-7215 (910) 350-2004 Fax Alexander, Cabarrus, Catawba, Cleveland, Gaston, Iredell, Lincoln, Mecklenburg, Rowan, Stanly, Union Chatham, Durham, Edgecombe, Franklin, Granville, Halifax, Johnston, Lee, Nash, Northampton, Orange, Person, Vance, Wake, Warren, Wilson Beaufort, Bertle, Camden, Chowan, Craven, Currituck, Dare, Gates, Greene, Hertford, Hyde, Jones, Lenoir, Martin, Pamlico, Pasquotank, Perquimans, Pitt, Tyrrell, Washington, Wayne Brunswick, Carteret, Columbus, Duplin, New Hanover, Onslow, Pender Winston-Salem Regional Office 450 W. Hanes Mill Road Alamance, Alleghany, Ashe, Caswell, Davidson, Water Quality Section Suite 300 Davie, Forsyth, Guilford, Rockingham, Randolph, Winston-Salem, North Carolina 27105 Stokes, Surry, Watauga, Wilkes, Yadkin (336)776-9800 (336) 776-9797 Fax INSTRUCTIONS FOR FORM: FTA 10-23 & SUPPORTING DOCUMENTATION Page 3 of