Loading...
HomeMy WebLinkAboutSW6241005_Supplement-EZ Form_20241105 SUPPLEMENT-EZ COVER PAGE FORMS LOADED I PROJECT INFORMATION 1 Project Name _ _ Compton Addy-Popeyes-Spout Springs,NC _ 2 Project Area(ac) 0.96 3 Coastal Wetland Area(ac) 0 4 Surface Water Area(ac) 0.18 5 Is this project High or Low Density? High 6 Does this project use an off-site SCM? No COMPLIANCE WITH 02H.1003(4) 7 Width of vegetated setbacks provided(feet) 10 8 Will the vegetated setback remain vegetated? No 9 If BUA is proposed in the setback,does it meet NCAC 02H.1003(4)(c-d)? N/A _ 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 Infiltration System l 0 12 Bioretention Cell {I 0 13 Wet Pond I 0 14 Stormwater Wetland 0 15 Permeable Pavement 0 _ 16 Sand Filter 1 17 Rainwater Harvesting(RWH) 0 18 Green Roof 0 19 Level Spreader-Filter Strip(LS-FS) 0 20 Disconnected Impervious Surface(DIS) 0 21 Treatment Swale 0 22 Dry Pond 0 23 StormFilter 0 _ 24 Silva Cell 0 25 Bayfilter 0 26 Filterra 0 FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: i Jeff Tibbitts 28 Organization: _ CESO 29 Street address: 3601 Rigby Road,Suite 300 _ 30 City,State,Zip: Miamisburg,OH 45342 31 Phone number(s): (614)370-8104 32 Email: tibbitts@legacy5.com Certification Statement: I certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision;that the information provided in the form is,to the best of my knowledge and belief,true,accurate,and complete;and that the engineering plans, specifications,operation and maintenance agreements and other supporting information are consistent with the information provided here. Designer -) y1^ ws.SSSSSSS qr f: s•s nature of esi er 7- '-' ry Ci i ..P.0- i ,f �j e K... al A �,;`µ Date /0 . 0 * >-u,>,w:1av DRAINAGE AREAS 1 Is this a high density project? I Yes 2 If so,number of drainage areas/SCMs I 1 _ 3 Does this project have low density areas? No _ 4 If so,number of low density drainage areas _ 0 Is all/part of this project subject to previous rule 5 versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site 1 4 Type of SCM Sand Filter Sand Filter 5 Total drainage area(sq ft) 49700 49700 6 Onsite drainage area(sq ft) 49700 49700 7 Offsite drainage area(sq ft) 0 0 8 Total BUA in project(sq ft) 30500 sf 30500 sf New BUA on subdivided lots(subject to permitting) 9 (sq ft) sf sf New BUA not on subdivided lots(subject to 10 permitting)(sf) 30500 sf 30500 sf 11 Offsite BUA(sq ft) sf sf 12 Breakdown of new BUA not on subdivided lots: 0 -Parking(sq ft) 20760 sf 20760 sf -Sidewalk(sq ft) sf _ sf -Roof(sq ft) 1990 sf — 1990 sf -Roadway(sq ft) sf sf -Future(sq ft) sf sf -Other,please specify in the comment box below(sq ft) _ _ 7750 sf 7750 sf , New infiltrating permeable pavement on 13 subdivided lots(sq ft) sf _— sf _ New infiltrating permeable pavement not on 14 subdivided lots(sq ft) sf _ sf _ Existing BUA that will remain(not subject to 15 permitting)(sq ft) _ sf sf 16 Existing BUA that is already permitted(sq ft) sf sf 17 Existing BUA that will be removed(sq ft) sf sf _ 18 Percent BUA 61% 61% 19 Design storm(inches) 8.3 in 8.3 in 20 Design volume of SCM(cu ft) 5957 cf _ 5957 cf 21 Calculation method for design volume -SCS SCS ADDITIONAL INFORMATION Please use this space to provide any additional information about the 22 drainage area(s): Sand Filter Impervious Area SAND FILTER 1 Drainage area number 1 2 Minimum required treatment volume(cu ft) 2065 sf GENERAL MDC FROM 02H.1050 3 Is the SCM sized to treat the SW from all surfaces at build-out? (s Yes 4 Is the SCM located away from contaminated soils? Yes 5 What are the side slopes of the SCM(H:V)? _ 6 Does the SCM have retaining walls,gabion walls or other engineered No side slopes? 7 Are the inlets,outlets,and receiving stream protected from erosion Yes (10-year storm)? j 8 Is there an overflow or bypass for inflow volume in excess of the Yes design volume? i 9 What is the method for dewatering the SCM for maintenance? [ Drawdown Orifice 10 If applicable,will the SCM be cleaned out after construction? I N/A 11 Does the maintenance access comply with General MDC(8)? Yes 12 Does the drainage easement comply with General MDC(9)? _ Yes If the SCM is on a single family lot,does(will?)the plat comply with 13 N/A General MDC(10)? — 14 Is there an O&M Agreement that complies with General MDC(11)? Yes 15 Is there an O&M Plan that complies with General MDC(12)? Yes 16 Does the SCM follow the device specific MDC? Yes 17 Was the SCM designed by an NC licensed professional? Yes SAND FILTER MDC FROM 02H.1056 181SHWT elevation((rust) 336 19_Type of sand filter(open or closed) Open 20 If closed,will the filter will be pre-cast or pour-in-place? 21 If dosed,top of grate elevation(fmsl) 22 1 Is this sand filter designed to attenuate peak flows? Yes Sediment Chamber 23 Volume that can be retained in the sediment chamber(cubic feet) 5615 cf 24 Will there be a permanent pool in the sediment chamber? No 25 Bottom of the sediment chamber(fmsl) I 336.50 26 Area of the sediment chamber(square feet) I 1011 sf 27 Physical depth of the sediment chamber(inches) 36 in 28 Ponding depth in the sediment chamber,above any permanent pool 36 in inches) 29 Elevation of top of weir between chambers(fmsl) 336.5 Sand Chamber 301Volume that can be retained in the sand chamber(cubic feet) 6172 cf 31 Bottom of the sand chamber(fmsl) 334.00 32 Area of the sand chamber(square feet) 1203 sf 33 Physical depth of the sand chamber(inches) 66 in Ponding depth in the sand chamber,above the sand surface 36 in (inches) 35 Elevation of the bypass device(fmsl) 339.5 36 Type of bypass device Spillway 37 Mechanism for distributing flow over the sand surface Underdrain 38 Sand specification for sand chamber ASTM C33 39 Depth above underdrain pipe(inches) 24 in 40 Will the media be maintained to drain at least two inches per hour at Yes the sand surface? 41 Is at least one clean-out pipe provided at the low point of each Yes underdrain line? 42 Will clean-out pi es be capped? Yes ADDITIONAL INFORMATION 43 Please use this space to provide any additional information about the (sand filter(s): _ Sand Filter 3 11:34 AM 10/10/2024 SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 Project Name Compton Addy-Popeyes-Spout Sprin,s,NC 2 Project Area(ac) 0.96 3 Coastal Wetland Area(ac) 0 4 Surface Water Area(ac) 0.18 5 Is this project High or Low Density? High 6 Does this project use an off-site SCM? No COMPLIANCE WITH 02H.1003(4) 7 Width of vegetated setbacks provided(feet) 1 10 8 Will the vegetated setback remain vegetated? No 9 If BUA is proposed in the setback,does it meet NCAC 02H.1003(4)(c-d)? N/A 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 'Infiltration System 0 12 Bioretention Cell 0 13 Wet Pond I 0 14 Stormwater Wetland 0 15 Permeable Pavement 0 _ 16 Sand Filter 1 17 Rainwater Harvesting(RWH) 1 0 18 Green Roof 1 0 19 Level Spreader-Filter Strip(LS-FS) 0 20 Disconnected Impervious Surface(DIS) 0 21 Treatment Swale 0 22 Dry Pond 0 23 StormFilter 0 24 Silva Cell 0 25 Bayfilter 0 26 Filterra 0 FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: j Jeff Tibbitts 28 Organization: _CESO 29 Street address: _ 3601 Rigby Road,Suite 300 30 City,State.Zip: Miamisburg,OH 45342 31 Phone number(s): _ (614)370-8104 32 Email: tibbitts@legacy5.com Certification Statement I certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision;that the information provided in the form is,to the best of my knowledge and belief,true,accurate,and complete;and that the engineering plans, specifications,operation and maintenance agreements and other supporting information are consistent with the information provided here. Designer Caw• ,v,1".�„,,.. `:;1Ny 4 sr, �% a as itr: � -o D: igrt r = 7 x d L it 'Cli F��Q�S[� / )A.1�® lU 2y .. ""Stie "e"°° Date DRAINAGE AREAS 1 Its this a high density project? I Yes 2 L If so,number of drainage areas/SCMs I 1 3 .Does this project have low density areas? No , 4 If so,number of low density drainage areas 0 Is all/part of this project subject to previous rule 5 versions? No FORMS LOADED DRAINAGE AREA INFORMATION Entire Site 1 4 Type of SCM Sand Filter Sand Filter 5 Total drainage area(sq ft) 49700 49700 6 Onsite drainage area(sq ft) 49700 49700 7 Offsite drainage area(sq ft) 0 0 8 Total BUA in project(sq ft) 30500 sf 30500 sf New BUA on subdivided lots(subject to permitting) 9 (sq ft) sf sf New BUA not on subdivided lots(subject to 10 permitting)(sf) 30500 sf 30500 sf 11 Offsite BUA(sq ft) sf sf 12 Breakdown of new BUA not on subdivided lots: 0 -Parking(sq ft) 20760 sf 20760 sf -Sidewalk(sq ft) sf sf -Roof(sq ft) 1990 sf 1990 sf -Roadway(sq ft) sf sf -Future(sq ft) sf sf -Other,please specify in the comment box below(sq ft) — 7750 sf 7750 sf New infiltrating permeable pavement on 13 subdivided lots(sqft) sf sf New infiltrating permeable pavement not on 14 subdivided lots(sq ft) — sf _ sf Existing BUA that will remain(not subject to 15 permitting)(sq ft) sf sf 16 Existing BUA that is already permitted(sq ft) sf sf 17 Existing BUA that will be removed(sq ft) sf sf 18 Percent BUA 61% 61% 19 Design storm(inches) 8.3 in 8.3 in 20 Design volume of SCM(cu ft) 5957 cf 5957 cf 21 Calculation method for design volume SCS SCS rADDITIONAL INFORMATION Please use this space to provide any additional information about the 22 drainage area(s): Sand Filter Impervious Area SAND FILTER 1�Drainage area number J 1 2I Minimum required treatment volume(cu ft) 2065 sf GENERAL MDC FROM 0214.1050 3,Is the SCM sized to treat the SW from all surfaces at build-out? Yes 4 Is the SCM located away from contaminated soils? Yes 5 What are the side slopes of the SCM(H:V)? 6 Does the SCM have retaining walls,gabion walls or other engineered No side slopes? 7 Are the inlets,outlets,and receiving stream protected from erosion Yes (10-year storm)? I 8 Is there an overflow or bypass for inflow volume in excess of the Yes design volume? 9 What is the method for dewatering the SCM for maintenance? Drawdown Orifice 10 If applicable,will the SCM be cleaned out after construction? N/A 11 Does the maintenance access comply with General MDC(8)? 1 Yes 12 Does the drainage easement compy with General MDC(9)? Yes If the SCM is on a single family lot,does(will?)the plat comply with f 13 N/A General MDC(10)? — — 14 Is there an O&M Agreement that complies with General MDC(11)? Yes 15 Is there an O&M Plan that complies with General MDC(12)? Yes 16 Does the SCM follow the device specific MDC? Yes 17 Was the SCM designed by an NC licensed professional? I Yes SAND FILTER MDC FROM 02H.1056 18 SHWT elevation(fmsl) 336 19 Type of sand filter(open or closed) Open 20 If closed,will the filter will be pre-cast or pour-in-place? 21 If closed,top of grate elevation(msq 22 Is this sand filter designed to attenuate peak flows? Yes Sediment Chamber 23 Volume that can be retained in the sediment chamber(cubic feet) 5615 cf 24 Will there be a permanent pool in the sediment chamber? No 25 Bottom of the sediment chamber(fmsl) 336.50 26 Area of the sediment chamber(square feet) 1011 sf 27 Physical depth of the sediment chamber(inches) 36 in 28 Ponding depth in the sediment chamber,above any permanent pool 36 in (inches) 29 Elevation of top of weir between chambers(fmsl) 336.5 Sand Chamber 30IVolume that can be retained in the sand chamber(cubic feet) 6172 cf 31 Bottom of the sand chamber(fmsl) I 334.00 32 Area of the sand chamber(square feet) 1203 sf 33'Physical depth of the sand chamber(inches) 66 in Ponding depth in the sand chamber,above the sand surface 36 in (inches) 35 Elevation of the bypass device(fmsl) 339.5 36 Type of bypass device I Spillway 37 Mechanism for distributing flow over the sand surface Underdrain 38 Sand specification for sand chamber ASTM C33 39 Depth above underdrain pipe(inches) 24 in _ 40 Will the media be maintained to drain at least two inches per hour at Yes the sand surface? 41 Is at least one clean-out pipe provided at the low point of each Yes underdrain line? 42,WiII clean-out pipes be capped? Yes ADDITIONAL INFORMATION 43I Please use this space to provide any additional information about the I sand filter(s): Sand Filter 3 11:34 AM 10/10/2024