HomeMy WebLinkAboutSW3240602_Supplement-EZ Form_20241023 SUPPLEMENT-EZ COVER PAGE
FORMS LOADED
1PROJECT INFORMATION
1 Project Name Cottages at Wingate-Phase 1
2 Project Area(ac) 72.10
3 Coastal Wetland Area(ac) N/A
4 Surface Water Area(ac) 2.91
5 Is this project High or Low Density? High
6 Does this project use an off-site SCM? No
COMPLIANCE WITH 02H.1003(4) mIM •
7 Width of vegetated setbacks provided(feet) 30'
8 Will the vegetated setback remain vegetated? Yes
9 If BUA is proposed in the setback,does it meet NCAC 02H.1003(4)(c-d)? N/A
10 Is streambank stabilization proposed on this project? No
NUMBER AND TYPE OF SCMs:
11 I Infiltration System
12 Bioretention Cell
13 Wet Pond 3
14 Stormwater Wetland
15 Permeable Pavement
16 Sand Filter
17 Rainwater Harvesting(RWH)
18 Green Roof
19 Level Spreader-Filter Strip(LS-FS)
20 Disconnected Impervious Surface(DIS)
21 Treatment Swale
22 Dry Pond
23 StormFilter
24 Silva Cell
25 Bayfilter
26 Filterra
FORMS LOADED
DESIGNER CERTIFICATION
27 Name and Title: Matthew C.Kirchner,PE
28 Organization: Eagle Engineering,Inc.
29 Street address: 2013-A Van Buren Ave
30 City,State,Zip: Indian Trail,NC 28079
31 Phone number(s): 704-882-4222
32 Email: mkirchner@eagleonline.net
Certification Statement:
I certify,under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision;that the
information provided in the form is,to the best of my knowledge and belief,true,accurate,and complete;and that the engineering plans,
specifications,operation and maintenance agreements and other supporting information are consistent with the information provided here.
Designer
\\ \\\III11///i,
\\\��N C A f' 0,
N
-7 5- Signature of Designer
SEAL
04550 =
/, E ..- I 10/23/2024
'/ // eea0C'' 1623/2024 Date
0/IIIIII\\\
DRAINAGE AREAS
1 Is this a high density project? Yes
2 If so,number of drainage areas/SCMs 3
3 Does this project have low density areas? No
4 If so,number of low density drainage areas 0
Is all/part of this project subject to previous rule
5 versions? No
FORMS LOADED
DRAINAGE AREA INFORMATION Entire Site 1 2 3
4 Type of SCM Wet Pond Wet Pond Wet Pond
5 Total drainage area(sq ft) 3,291,109 sf 1,194,724 sf 459,674 sf 233,461 sf
6 Onsite drainage area(sq ft) _ 3,267,436 sf 1,171,051 sf 459,674 sf 233,461 sf
7 Offsite drainage area(sq ft) 23,673 sf 23,673 sf 0 sf 0 sf
8 Total BUA in project(sq ft) 738,700 sf 498,248 sf 174,676 sf _ 65,776 sf
New BUA on subdivided lots(subject to permitting)
9 (sq ft) 498,840 sf 331,323 sf 121,722 sf 45,795 sf
New BUA not on subdivided lots(subject to
10 permitting)(sf) 216,187 sf 143,252 sf 52,954 sf 19,981 sf
11 Offsite BUA(sq ft) 23,673 sf 23,673 sf 0 sf 0 sf
12 Breakdown of new BUA not on subdivided lots:
-Parking(sq ft) 19,488 sf 19,488 sf 0 sf 0 sf
-Sidewalk(sq ft) 7,334 sf 3,481 sf 2,318 sf 1,535 sf
-Roof(sq ft) 0 sf 0 sf 0 sf 0 sf
-Roadway(sq ft) 189,365 sf 120,283 sf 50,636 sf 18,446 sf
-Future(sq ft) 0 sf 0 sf 0 sf 0 sf
-Other,please specify in the comment box
below(sq ft) 0 sf 0 sf 0 sf 0 sf
New infiltrating permeable pavement on
13 subdivided lots(sq ft) 0 sf 0 sf 0 sf 0 sf
New infiltrating permeable pavement not on
14 subdivided lots(sq ft) 0 sf 0 sf 0 sf 0 sf
Existing BUA that will remain(not subject to
15 permitting)(sq ft) 0 sf 0 sf 0 sf 0 sf
16 Existing BUA that is already permitted(sq ft) 0 sf 0 sf 0 sf 0 sf
17 Existing BUA that will be removed(sq ft) 0 sf 0 sf 0 sf 0 sf
18 Percent BUA 22% 42% 38% 28%
19 Design storm(inches) 5.3 in 5.3 in 5.3 in 5.3 in
20 Design volume of SCM(cu ft) 111,344 cf 63,260 cf 15,167 cf 7,785 cf
21 Calculation method for design volume Simple Method Simple Method Simple Method Simple Method
ADDITIONAL INFORMATION _
Please use this space to provide any additional information about the
22 drainage area(s):
WET POND
1 Drainage area number Al A2 A3
2 Minimum required treatment volume(cu ft) 49,645 cf I 15,016 cf I 5,906 cf
GENERAL MDC FROM 02H.1050
3 Is the SCM sized to treat the SW from all surfaces at build-out? Yes Yes Yes
4 Is the SCM located away from contaminated soils? Yes Yes Yes _
5 What are the side slopes of the SCM(H:V)? 3:1 3:1 3:1
6 Does the SCM have retaining walls,gabion walls or other engineered No No No
side slopes?
7 Are the inlets,outlets,and receiving stream protected from erosion Yes Yes Yes
(10-year storm)?
8 Is there an overflow or bypass for inflow volume in excess of the Yes Yes Yes
design volume?
9 What is the method for dewatering the SCM for maintenance? _ Pump(preferred) Pump(preferred) Pump(preferred)
10 If applicable,will the SCM be cleaned out after construction? Yes Yes Yes
_ 11 Does the maintenance access comply with General MDC(8)? Yes Yes Yes
12 Does the drainage easement comply with General MDC(9)? Yes Yes Yes
13 If the SCM is on a single family lot,does(will?)the plat comply with N/A N/A N/A
General MDC(10)?
14 Is there an O&M Agreement that complies with General MDC(11)? Yes Yes Yes
15 Is there an O&M Plan that complies with General MDC(12)? _ Yes Yes _ Yes _
16 Does the SCM follow the device specific MDC? Yes Yes Yes
17 Was the SCM designed by an NC licensed professional? Yes Yes Yes
WET POND MDC FROM 02H.1053 •
18 Sizing method used SA/DA SA/DA SA/DA
19 Has a stage/storage table been provided in the calculations? _ Yes Yes Yes
20 Elevation of the excavated main pool depth(bottom of sediment 507.00 509.00 525.00
removal)(fmsl)
21 Elevation of the main pool bottom(top of sediment removal)(fmsl) 508.00 510.00 526.00
22 Elevation of the bottom of the vegetated shelf(fmsl) _ 512.00 514.00 532.00
23 Elevation of the permanent pool(fmsl) 512.00 514.00 532.00
24 Elevation of the top of the vegetated shelf(fmsl) 513.00 515.00 533.00 _
25 Elevation of the temporary pool(fmsl) 513.25 515.00 533.00
26 Surface area of the main permanent pool(square feet) 36,137 sf 10,853 sf 4,067 sf _
27 Volume of the main permanent pool(cubic feet) 124,658 cf 36,061 cf _ 16,283 cf _
28 Average depth of the main pool(feet) 3.40 ft 3.30 ft 4.00 ft _
29 Average depth equation used Equation 2 Equation 2 _ Equation 2 _
30 If using equation 3,main pool perimeter(feet) N/A N/A N/A
31 If using equation 3,width of submerged veg.shelf(feet) N/A N/A N/A
32 Volume of the forebay(cubic feet) 20,643 cf 6,280 cf 2,963 cf _
33 Is this 15-20%of the volume in the main pool? Yes Yes _ Yes _
34 Clean-out depth for forebay(inches) 48 in 48 in 36 in
35 Design volume of SCM(cu ft) 49,853 cf 15,167 cf 7,785 cf
36 Is the outlet an orifice or a weir? Orifice Orifice Orifice
37 If orifice,orifice diameter(inches) 3.5 in 2 in 1.5 in
38 If weir,weir height(inches) 0 in 0 in 0 in
39 If weir,weir length(inches) 0 in 0 in 0 in
40 Drawdown time for the temporary pool(days) 3.36 3.02 2.73
41 Are the inlet(s)and outlet located in a manner that avoids short- Yes Yes Yes
circuiting? _
42 Are berms or baffles provided to improve the flow path? — Yes Yes _ Yes _
43 Depth of forebay at entrance(inches) 66 in 66 in 54 in
44 Depth of forebay at exit(inches) 54 in 54 in 42 in
45 Does water flow out of the forebay in a non-erosive manner? Yes Yes Yes
46 Width of the vegetated shelf(feet) _ 6 ft 6 ft 6 ft
47 Slope of vegetated shelf(H:V) — 6:1 6:1 6:1 _
48 Does the orifice drawdown from below the top surface of the Yes Yes Yes
permanent pool? _
49 Does the pond minimize impacts to the receiving channel from the 1- Yes Yes Yes
yr,24-hr storm?
50 Are fountains proposed?(If Y,please provide documentation that No No No
MDC(9)is met.)
51 Is a trash rack or other device provided to protect the outlet system? Yes Yes Yes
52 Are the dam and embankment planted in non-clumping turf grass? Yes Yes Yes
53 Species of turf that will be used on the dam and embankment Centipede Grass Centipede Grass _Centipede Grass
54 Has a planting plan been provided for the vegetated shelf? Yes Yes Yes
ADDITIONAL INFORMATION
55 Please use this space to provide any additional information about the
wet pond(s):
Wet Pond 3 11:36 AM 3/22/2024