Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SW5240801_Plansheet - Proposed Conditions/Site Plan_20241104
TED G. GUPTON / PIN #286015620792 / LEGEND D.B. 1528, PG. 335 / N LINES SURVEYED LINES NOT SURVEYED 00 STIR. #15 - - OVHD DISTRIBUTION LINE(OVERHEAD) O GUY WIRE G GAS LINE CATV N2000'59"W CIO - UNDERGROUND CABLE — — — — — — — — GRAVEL LINE RIGHT OF WAY LIMITS -- Riw ROAD RIGHT OF WAY \ —-- -- DITCH LINE \' ; �0;' 0,: W WATER LINE EXISTING 66KV LINE i UT UNDERGROUND TELEPHONE LINE (PER CP&L MAP L-A-2995 MAP OF LAND TO \ / WOODS LINE BE AQUIRED FROM ADOLPH C. BRANTLEY UE UNDERGROUND ELECTRIC LINE FOOR THE SPRING HOPE 115KV I S SANITARY SEWER LINE SUBSTATION, DATED JUL, 1972 / i ] —xxxxx FENCE LINE O PROPERTY CORNER(FOUND) ❑0 EXISTING CONCRETE MONUMENT .j / WELCOME SELF STORAGE 2, LLC \ � LIGHT POLE ' J TREE �, STRUCTURE i \ \ WIRE HEIGHT LOCATION NTS T T ALE\' ! ( ) NOO SC PIN #286015622642 D.B. 3274, PG. 774 o \ 0 Pt POINT NOT SET POWER BOX / TELEPHONE PEDISTAL .I \ o CP COMPUTED POINT 00 PROPOSED REVISED ' TREE LINE / \ \ CONTROL POINT SIGN POST O TIMBER FOUNDATIONS TELEPHONE PEDISTAL FENCE CORNER / © WATER MANHOLE STR. #14 O WATER METER FIRE HYDRANT v ® WATER VALVE 0 N 8.00' \ 0 \ 00 TYPE A I DISTURBANCE URBANCE (TYP)POSED LIMITS F 00 O , DUKE ENERGY LOD LIMITS OF DISTURBANCE �I LANDSCAPE BUFFER ' PROGRESS o zz I; PIN #286015633084 \ w D.B. 2678, PG. 166 PROPOSED TREE LINE D.B. 586, PG. 490 GRAVEL SHOULDER Ld oo D.B. 893, PG. 621 Cn ZONING: GB o \ \ \ \ \ ACCESS ROAD LO 3 STEPHEN DEAN \ " " .. ' TYPE A LANDSCAPE BUFFER 77 BATCHELOR I d� EXISTING VEGETATION TO SERVE AS a� N .(15 .1p^ \ BUFFER WHERE NOT BEING DISTURBED r o o PIN #286015623232 ° a , O o ND.B. 1165, PG. 416 CD \ " " SEE SHEET 16 FOR LANDSCAPE PLANTING � tO ZONING: GB \ \ o n PLAN. "''; 4. ,' CONCRETE PAVEMENT APRON N I ^; SEE DETAIL 6/SH. 18 6.00' STEPHEN DEAN 67� o- POLE MOUNTED MICRO LED SHOULDER \ SITE INFORMATION: BATCHELOR S3°13'16"W ROADWAY SITE LIGHTS ■ 0 \ 1. PROPERTY OWNER: DUKE ENERGY PROGRESS, LLC. PIN #286015624653 \ 50 WATTS ; \ (FORMERLY CAROLINA POWER& LIGHT CO.) n D.B. 1845, PG. 706 MOUNTED HEIGHT = 25' ! \ \ , 411 FAYETTEVILLE STREET 1-1 ZONING: GB Lo o Oo ;;;I (BY OTHERS) R6.00' RALEIGH, NC 27601 ° L0 = REPLACE AND RAISE 2. PARCEL PIN#: 286015633084 U) �; :; ;I STR. #13 (BY OTHERS) a ; 3. CURRENT ZONING: GENERAL BUSINESS (GB) 0 89.08 o I m■ \ \ 4. CURRENT AND PROPOSED USE: ELECTRIC SUBSTATION POTENTIAL 0- i 5. SITE IS NOT LOCATED WITHIN A FEMA 100-YR FLOODWAY, FIRM cn POLE/GUY WIRE ro \CONFLICTS m \ PANEL 3720286000J, EFFECTIVE DATE 11/03/2004. cn C14 c� „� `vim — — °°— GG— 1 \ 6. PARCEL IS LOCATED IN THE TAR-PAMLICO RIVER BASIN. 0 Op GG—UDG 1— <- � ' m ; \ \ \ \\ 7. NO HAZARDOUS MATERIALS WILL BE USED OR STORED ON-SITE. 04 Q a POTENTIAL / r r IL- __ - U) � U POLE/GUY WIRE m 8. NO GARBAGE OR SOLID WASTE COLLECTION REQUIRED. r- 2 CONFLICTS 9. SITE LIGHTING INSTALLED WITHIN FENCED AREA WILL EMIT LESS > m / / ; N:803089.96 j Q DISTRIBUTION :;;l ( ! E:2266536.68 \ THAN ONE FOOT-CANDLE AT ANY PROPERTY LINE. N z = a 00 POLE I.D. / C`fo R/W AS SOWN On N MAP FOI O e3 I ir; • — 9 _ ° ■ — 25DQ15 N I�;;I ��� °° °o — —°o —°° g° — 10. PRELIMINARY TOPOGRAPHIC AND BOUNDARY SURVEY PREPARED o �- CAROLINA POWER & LIGHT CO. e (0 ,�, . L ,�p0' �i 99 — - - NORTH-SOUTH BASELINE \ BY DMP SURVEYING INC, (BRADLEY PHILLIPS, PLS), DATED I w d DWG NO RA_Q7n9 In A A ^ DISTRIBUTION .' I ;I b'�/ i In • _ 10/19/2023 AND REVISED 06/10/2024. `. PROPOSED FIRE o -I-I-I - - -I o HYDRANT RELOCATION. / �I - — LANDSCAPE BUFFER O POLE I.D. . . .... . ;.. . . ... .., � . . rd. � . ..�...... ... .. . . . ... . . � A \ SEE SHEET 10.2 25DQ13 ' �//P _ C - , LIMITS OF DISTURBANCE c ° _ — w _ N59 24 41.96"W _ — o REPLACE TAP STR. #1 I ° � 10.72 � � . (BY OTHERS) TOTAL AREA: 10.0 AC — 0=F N Qel N 1 04 21 v v I \ o :8:00' 0 - -,-, — ------ — — x ■ \ ICn POLE MOUNTED MICRO LED ROADWAY w SITE LIGHTS a ' I 5 ' i -ci I 50 WATTS PROPOSED / MOUNTED HEIGHT = 25' CONCRETE APRON o„'t I ■ (BY OTHERS) o 15" RCP CULVERT 6.00' "?^r? SEE SHEET 10 N I _ — — — — — SHOULDER bl N o r ~''Fr _ N2° 2.90" u Q 1 FL'15� - \ o I moo;;"';;;;..�, , E o D=4.33'���^ N2° 04' 30.18'W i \� , •�`'� ,.r,.„ =37.75, R=500.00 - 117.10 I ,; ACCESS ROAD POTENTIAL Q ;r`' I' R20.00' — POLE/GUY WIRE , � I �'` � �— GRASSED � zQ y*�. --- — — — — SHOULDER (TYP.) CONFLICTS 0 p � eD��•� -L�q'�� o_ Ii I 77 _ oo 2 4 _ rYYYJ-1r'� — ' y w SO 502 L6� :0 1•�• —L ■ — �J 30 Graphic Scale S4 03'3 E 30 60 FTSO°08'38"E o PROPOSED REPLACE AND RAISE STIR. ,, I 8 00' 1 inch = 30 feet 0 ACCESS ROAD #1+ 0(B OTHERS)AWAY J TYPE A PROPOSED REVISED EX. 15" RCP LANDSCAPE BUFFER TREE LINE (NOT SHOWN IN THIS VIEW) " DUKE a PROPERTY LINE/ NCDOT = RIGHT OF WAY ENERGY. rn JFG ELECTRIC, INC. RICHARD HOWARD FERGUSON AND L EXISTING PIN #268015628604 PROPERTY LINE (TYP) WIFE, IRENE CREEKMORE WSP USA OVERHEAD D.B. 2130, PG. 386 FERGUSON ENVIRONMENT& INFRASTRUCTURE INC. DISTRIBUTION LINE ZONING: GB 5710 OLEANDER DRIVE,SUITE 110 PROGRESS PIN #286015721905 WILMINGTON,NC 28403 cn D.B. 1697, PG. 311 TEL:(910)452-1185 FAX:(844)648-9591 411 FAYETTEVILLE STREET SECOND TRACT ENG.LICENSURE:F-1253 TELEPHONE N0. (919) 546-2090 F 08/01/2024 ISSUED FOR REVIEW- 100% DESIGN WMN ML TL " N •C•AR '',,,'''' � TITLE ,.�• '( O SPRING HOPE 115KV E 05/10/2024 ISSUED FOR REVIEW- 95% DESIGN WMN BBC TL 141 �••FE s� ••�� ��= SUBSTATION REBUILD D 04/19/2024 ISSUED FOR REVIEW- 75% DESIGN WMN DCO TL _ ; _ = SITE PLAN 052297 cn C 03/15/2024 ISSUED FOR REVIEW- 50% DESIGN WMN BBC TL •:, = �' LOCATION 805 EAST NASH STREET, SPRING HOPE, NC T FINAL DRAWINGS - '=`C� '�HGtNE��''• ,` 0° B 03/01/2024 ISSUED FOR REVIEW- 30% CONCEPTUAL RS WMN TL O • ••• x "_ SCALE AS SHOWN SCALE RATIO 1:1 DEP PRJ. NO. 170911AO1 FOR REVIEW �'',.,,,��„/`/11H1111„�\ ���o� DRAWN WMN CHK. ML APP. TL A 12/15/2023 ISSUED FOR REVIEW-25/o CONCEPTUAL WMN BBC TL PURPOSES ONLY 08/01/2024 0 N0. DATE REVISION DR. CK. APP. DATE 08/01/2024 JOB NO. 7818230203 DWG NO.: RDC-28668- 5 OF 18