HomeMy WebLinkAboutSW6240905_Plansheet - Other_20241016 (2) N/F LGI HOMESFNC, LLC 4Dsite
LGI HOMES—NC, LLC TRACT 1 & 2 OF
,/ TRACT 2 OF DB 3290, PG 659
/ v + + + ♦♦ / PB 2022, PG 29 PB 2023, PG 384 solutions
J1 I civil engineering I land surveying
— ° p • 409 Chicago Drive,Suite 112,Fayetteville,NC 28306
J`-/ + �/_ ♦ office 1910-426-6777 fax 1910-426-5777 license number I C-2354
ffi+�/� / / \ www.4Dsitesotutions.com
J ✓ (1 X + __.vim-:v + + +♦��— f k
00
\
ECM LEGEND: / 1 �✓/ 1 /� ��� + + + +
® ECM—EXISTING CONCRETE MONUMENT / L
EIP �X \ WOO+ f w + Z + + ♦ / _ ``���IIII /
(0 EIP—EXISTING IRON PIPE ` + +/ + + + 12 ��� CARD ///
ERGO EPK—EXISTING PK NAIL + +/ + + + + *&ESS/�
ERSO ERB—EXISTING REBAR / j +J ( + _ + + +♦J�!' / 2S5 \ I Q� <•.'
Op ERS—EXISTING RAILROAD SPIKE / 1 I \ "/. +��� \ \ - SEA
a COMPUTED POINT \ ~ I 02 4
N/F — NOW OR FORMERLY CA1 / — / ` \\ y a O
R/W — RIGHT OF WAY
PVC — POLYVINYL CHLORIDEIIIIB�`````
RCP — REINFORCED CONCRETE PIPE 2g5 / 1 l V \ CA2
PROPERTY LINE
ADJACENT PROPERTY LINE �Y / / 2" BO
TIE LINE /f� / 17+86.6� I'��° k /
—— RIGHT—OF—WAY /� / by / o�x y REVISIONS
ss SANITARY SEWER LINE / / wX I (� \
\ l 2" G �- r
SD STORM DRAINAGE �/j x / \ / 17+90V5
w WATER LINE
// OVERHEAD UTILITY f \
X FENCE LINE
WETLANDS — 10 } -----
^
UNSUITABLE SOIL
LINE 290— MAJOR CONTOUR _ r �0 �v W 2
291 MINOR CONTOUR � / � � J •��'� / \\ } ,
—-—-—-— LANDSCAPING BUFFER q - °o /
x 302.72'SPOT ELEVATION
BENCHMARK
N SIGN
FMB]MAILBOX
I
pp LIGHT POLE
• UTILITY POLE
C- GUY WIRE k U I 2" GV
❑T TELEPHONE PEDESTAL O / o0 16+23.7 O
D4 WATER VALVE /6" PLUG & TAP 2" 14
FIRE HYDRANT H� x 1 l
16+15.7 /
❑o WATER METER k _—\ FH I l
C SANITARY SEWER MANHOLE / 16+11.6 J x
ASPHALT
GRAVEL fBUILDINGS
WETLANDS k \ , eA 10' UTILITY & \ IN/ PROJECT NAME
UNSUITABLE SOIL ~ / 2
DRAINAGE EASEMENT
o( PROPOSED FIRE HYDRANT
❑■ PROPOSED WATER METER
►N PROPOSED WATER VALVE k j / *U BOONE
mv
►N PROPOSED TAP SLEEVE AND VALVE w
• PROPOSED BLOW OFF
F7-PROPOSED TEE \ �� TRAIL FARMS
► / / 1 l
PROPOSED PLUG k ` \ '
�4 Q \ W
Lu
x
-T_2 x SUBDIVISION
\ / / / 15 17
o 1 _� 0 Li
N/F
JOHNNYNFAIRCLOTH k \ ` / 0 16 \ k\ z
TRACT 5 OF C)
DB 3395, PG 642 / _f
PC C, SLIDE 644—B \ 1 I d 1 Q E—
Q
x _ w \
0
13+22.9 6" PLUG & TAP 2"
9+74.70 10+00 13+10.9 —__ s - DETAILED
—— _ o UTILITY— , — 11+00 _ m ' 10' U EASEMENT UTILITY PLAN
10+12.2 I
6"X6" TEE 12+00 29 k / _ s 295 -- --- _-- —
13+14.9 — W6 I— 3+00 ——
i ——— —— W 6" GV 14+00 L�.
�— -� ——— — W6 —� 13+86.4 6" GV FERNCLIF
y —__ FDR
'=- 14+02.4�—
x 2" GV FH 10' UTILITY EASEMENT _ ——�—— — W6 50' PUBLIC R/W — —I� —16+00 PIN:
N 413+02.9 10+53.8 _ 6"X6" TEE
10' UTILITY &DRAINAGE EASEMENT W6 —I —17f00
�♦ 13+42.0 — --_ -- Q
�� 13+94.4 W6 051 J-57-5161 ■000
W
Y R0' DRAINAGE
k /Q/ I I o I FH — 15' UTILITY -- — — EAS ———
:� ? 3 14+31.4 EASEMENT EMENT _ _ — CLIENT
❑ of I '
+ � IW� O 1 I "=F WJ 1 I
x � � { V _ I B LAND LL� : S C
to
to 1 I
ILL" i 1
-w
w ohs
I I
I 29s
O ' � 1 w j�
1 I Q I o W ,
+ Q (l lOZ)ES dbN 41 jO ON
�o I �N � 466 Stancil Road
i 300 Z Angler, North Carolina 27501
305 00 /o - \ �P
M s o� Phone: (919) 868 1733
_ cm) � 1 p
PROJECT INFORMATION
1 /
2 cv
�,
10+24.1 oh /
.00 � DESIGNED BY: CALEB
x _ DRAWN BY: CALEB
/ 2" BO CHECKED BY: SCOTT
10+20.7-_ o
E CONCRET f 3 1 PROJECT NUMBER: 2084
5' NO ACCESS , I ,
/ EASEMENT �� PEMVTp FH
X
N - --. �.�. .�. - \ _
o --- - -- I 10+54.9 �
-
_-_. 10'x70' SIGHT Know what's below. DRAWING SCALE
TRIANGLE (TYP) C1II before you dig.
5' NO ACCESS
HORIZONTAL: 1"=50'
/ ----
----- — ws _ 6"X6" TS&V—��' EASEMENT
- .�-- 10+17.4
Z -_-- -� o I _�
J) —�— +
LLI p
_ DATE RELEASED
o SR 1235 (ADCO GRAPHIC SCALE
— — _ —— m LOCATION EXISTING CK ROAD)
— — — --� FO o a _ 6" WATER LINE 60 PUBLIC R/W ) so 0 25 so ioo zoo AUGUST 22, 2024
/ 23
— ' 17 BS LAND, LLC DB 4177, PG 2935 N/F 1 — ——— __. SHEET NUMBER
—'
LL N/F I PB 2023, PG 266 A&G RESIDENTIAL, LLC IN FEET )
BS LAND, LLC / DB 4199, PG 1662 �� �� ' 1 inch = 50 ft.
— — 2 i I DB 4177, PG 2935 PB 2023, PG 266
— I PB 2023, PG 266
_ / Q N/F
'
— KFNNFTH N r.l1MMINGS \ SIGNATURE HOME BUILDERS, INC
C -41
THE CONTRACTOR MUST CONTACT NORTH CAROLINA ONE CALL CENTER AT 1 -800-632-4949 A MINIMUM OF 72 -HOURS PRIOR TO DIGGING IN ORDER TO HAVE THE EXISTING UTILITIES LOCATED '
m PB 2004 PG 464 \ G `D