HomeMy WebLinkAboutNCG550258_Compliance Evaluation Inspection_20161219 PAT MCCRORY
Governor
-• DONALD R. VAN DER VAART
Secretary
S. JAY ZIMMERMAN
Water Resources Director
ENVIRONMENTAL QUALITY
December 19, 2016 RECEIVEDINCDEQ/DWR
John Elkins DEC 2 8 2016
5411 Winders Lane Water Quality
Durham,NC 27712 Permitting Section
Subject: Compliance Evaluation Inspection
Single Family Wastewater Treatment System
Permit No. NCG550258
Durham County
Dear Mr. Elkins:
On November 29, 2016, Jane Bernard from the Raleigh Regional Office visited your single-
- family residence(SFR) wastewater treatment system to evaluate compliance with the above
permit to discharge wastewater. The checked boxes below show what conditions were noted at
your facility:
® In compliance: You are reminded to regularly maintain the chlorine disinfection and
dechlorination systems, have the effluent sampled once a year, and have the septic tank
pumped out every 3 to 5 years. Your good record of operation and meeting the permit
requirements is highly commended.
❑ Your home is improperly plumbed: Some of the wastewater discharges are going
directly to the environment without first passing through the treatment system. This must
be corrected immediately. Please submit a schedule to this office within 20 days of
receipt of this letter that states your plan for correcting this deficiency. The work is to be
completed within the next 3 months.
❑ Disinfection: Your system is lacking disinfection, either chlorine tablets or a UV light
system. New rules put into place on August 1, 2007 require all SFR systems to have a
means of disinfection(and dechlorination when chlorine tablets are used to disinfect, if
the system was installed since that date). Since your system had no disinfection,the
installation is to include a chlorine tablet dispenser, a contact chamber capable of
providing a minimum 30 minute contact time, and another tablet dispenser that will hold
dechlorination tablets. Please submit a schedule to this office within 20 calendar days of
receipt of this letter that states your plan for correcting this deficiency.
❑ Treatment tablets missing or are wrong kind: You are responsible for always
having chlorine tablets and dechlorination tablets (if a required part of your system) in
place. They must be the kind for wastewater treatment and not for swimming pools.
State of North Carolina I Environmental Quality I Water Resources I Raleigh Regional Office •
1628 Mail service Center I Raleigh,North Carolina 27699-1628
919 791-4200
John Elkins
December 19, 2016
❑ Dechlorination: Your system was installed after August 1, 2007, so must have a
means of dechlorination located downstream of the chlorinator and its contact chamber.
See Disinfection paragraph above. Please submit a schedule to this office within 20
calendar days of receipt of this letter stating your plan for correcting this deficiency.
❑ Pumping the septic tank: The septic tank should be pumped out every 3 to 5 years.
A pumping company can check the status periodically and determine when pumping is
required.
❑Failure to analyze the effluent: The effluent that is discharged from your system
must be analyzed once each year. See Part I(A) of your permit about his requirement. A
list of NC certified laboratories that provide this service was left at your residence during
the inspection. Make arrangements for sampling to be carried out within the next 3
months, and submit results to this office within 3 weeks after the sampling has been done.
❑ Locations of treatment units are unknown: Determine this and report to this office
within 30 days of receipt of this letter with a sketch or map.
- -- • Other: --
If you have questions or comments about this inspection or the requirements to take corrective
action,please contact Jane Bernard or me at 919-791-4200. Licensed plumbers should be used
to make plumbing changes within your home. Contractors for installing disinfection or other
equipment may be found in the Yellow Pages under Environmental Consultants.
Sincerely
‹,: 12/
S. Daniel Smith, Supervisor
Water Quality Regional Supervisor
Raleigh Regional Office ,
Attachments: Inspection Reports
cc: RRO/SWP Files
Charles Weaver,NPDES Permitting Unit
Durham County
United States Environmental Protection Agency Form Approved.
EPA Washington,D.C,20460 OMB No.2040-0057
Water Compliance Inspection Report Approval expires 8-31-98
Section A:National Data System Coding(i.e.,PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 Iti I 2 IS I 3 I NCG550258 .111 12 I 16/11/29 I17 1812.1 19 Ls]I 20I—I
21I 1 1 1 I I I I I I I I I I I I I , 1 I I I I I I I L I I I I I I I I I I I u --Il r6
Inspection Work Days Facility Self-Monitoring Evaluation Rating - B1 QA • Reserved
671 I 70 LJ I L
I 71 I I 72 1 ,, 1 731 I 174
Section B:Facility Data
L
Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Date Permit Effective Date
POTW name and NPDES permit Number) 11:30AM 16/11/29 13/08/01
5411 Winders Lane
Exit Time/Date Permit Expiration Date
5411 Winders Ln
12:00PM 16/11/29 18/07/31
Durham NC 27712
Name(s)of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data
Name,Address of Responsible Official/Title/Phone and Fax Number
Contacted
John Elkins,5411 Winders Ln Durham NC 27712//919-286-4049/
No
• Section C:Areas Evaluated During Inspection(Check only those areas evaluated)
El Permit El Operations&Maintenance -
•
Section D:Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s)and Signature(s)of Inspector(s) Agency/Office/Phone and Fax Numbers - Date
Jane Bernard Non Discharge Compliance Unit//919-79
Si atur of Management Q eviewer/ Agency/Office/Phone and Fax N mbers Date
67`,09,2y _./7,1A////
/
EPA Form 3560-3( ev 9-94)Previous editions are obsolete. �'�/
Page# 1
NPDES yr/mo/day Inspection Type 1
3I NCG550258 I11 121 16/11/29 117 18 I c,
Section D:Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary)
1•
Page# 2
r •
Permit: NCG550258 Owner-Facility: 5411 Winders Lane
Inspection Date: 11/29/2016 Inspection Type: Compliance Evaluation
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? • ❑ 0 ❑
Does the facility analyze process control parameters,for ex: MLSS, MCRT, Settleable ❑ ❑ • 0
Solids, pH,DO,Sludge Judge, and other that are applicable? •
Comment:
Permit Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new 0 ❑ • ❑
application?
Is the facility as described in the permit? • 0 0 ❑
#Are there any special conditions for the permit? 0 ❑ • ❑
Is access to the plant site restricted to the general public? ❑ ❑ • ❑
Is the inspector granted access to all areas for inspection? • 0 ❑ ❑
J- Comment:
Page# 3