Loading...
HomeMy WebLinkAboutWQ0028666_Monitoring - 08-2024_20240930Monitoring Report Submittal ................................................... Permit Number#* WQ0028666 Name of Facility:* Month: * August Cannonsgate at Bogue Sound Report Information Type * NDMR, NDAR-1, NDAR-2, NDMLR Confirmation Email Address: * Name of Submitter: * Signature: Date of submittal: Initial Review Year:* 2024 Upload Document* Cannonsgate bogue sound NDAR Aug 892.78KB 2024_09262024141148.pdf PDF Only Please upload one PDF containing all applicable monitoring reports (i.e., NDMR, NDAR-1, NDAR-2, NDMLR, GW-59). ksdickens@aquaamerica.com Katie McLean Reviewer: Wanda.Gerald 9/30/2024 This will be filled in automatically Is the project number correct?* W00028666 Is the monitoring report accepted?* Yes NO Regional Office* Wilmington Reviewer: _anonymous Review Date: 10/21/2024 FORM NDAR-2 10-13 NON -DISCHARGE APPLICATION REPORT (NDAR-2) Page -I of Permit No.: WQ0028666 Facility Name: Cannons Gate at Bogue Sound County: Carteret Month: August Year: 2024 Did infiltration occur at _ k this facility? Area (acres): �i rES No Rate (GPD/ft'): 1 Site Name: 2 Site Name: Site Name: 4 0.36 1.66 Area (acres): 0.67 Area (acres): 1 32 Area (acres): 1.145 Rate (GPD/ t1): 1,145 Rate (GPD!ft2Y i Rate (GPD/ft2): YLS; Site Infiltrated? 1.145 Weather Freeboard Site Irtllltrated? YES NO Site Infiltrated? ., YES NO Site Infiltrated? YES NO m m Om ec NE LL PD/ff ft > v ro 3vm0 O crimS u d E. u nEa i d p t7 .1 a LL E nH o 7 Q c J e AO LL E ro ~C _ro m j" E ro 4m C °F in I ft I ft gal min GPDKe I ft qal min ft I min GPDMe ft' al min 1 C 89 2.1 9,750 013 220 8,750 030 8,750 0.15 2.3 8,750 0.56 2.46 2 C 89 2.1 3.416 0.19 2-20 13,416 046 ; 2.60 13,416 0.23 2.3 13,416 0.86 2.40 t 3 R 88 0.03 21 113,416 0.19 2.20 13,416 0.46 � 2.60 13,416 0.23 2.3 13,416 0.86 0.86 2.40 2.40 4 R 83 0.27 21 3.416 0.19 2.20 13,416 0,46 2.60 13,416 0.23 2.3 13,416 5 R 83 0.1 2.4 �l1,750 0.16 2.40 11,750 0.40 2 60 11,750 020 2.3 11,750 0.75 2.40 6 R 83 0.88 2.4 3,500 0.19 2.40 'c 13,500 0,46 2 80 13,500 0 23 2.50>' 13,500 0.86 2.40 7 R 84 0.29 2.4 4,250 0.20 2.40 14,250 0.49 t 280 14.250 0.25 2.5g "A 14,250 0.91 1.08 2.50 2.50 8 R 83 0.65 2.6 7.000 0.24 2.70 .-. 17,000 0.58 260 17,000 0.30 2.50A 17,000 9 R 83 0.07 2.6 8.833 0.26 2.70 18,833 0.65 .2.60 16,833 0.33 2.50'-',,18,833 1.20 2.50 10 R 86 2.31 2.6 8,833 0.26 2.70 " 18,833 0.65 2.60 18,833 0.33 2 50 , 18,833 1.20 2.50 11 R 86 0.02 2.6 i8,833 0.26 2.70 18.833 0.65 2.60 18,833 0.33 2.50.A 18,833 1.20 2.50 12 R 87 2.03 24 18.750 0.26 2,50 18,750 0.64 2.8G 18,75U 0.33 2.50 '. 18,750 1 20 2.50 13 C 83 2.2 13,250 0.18 2.50 14,250 0.49 2.50 14,250 0.25 2.30- 14.250 091 2,20 14 C 87 2.2 16,250 0.22 2.70 16,250 0.56 2.50 16,250 0.28 2.30 -- 16,250 104 2.20 15 C 86 2.3 10.250 0.14 2.80 10,250 0.35 2.50 10,250 0.18 2.30 10,250 065 2.20 16 C 87 2.3 4,250 0.20 2.80 14,250 0.49 2.50 14.250 0.25 2.30 : 14,250 091 2.20 17 C 70 2.3 4.250 0.20 2,80 14,250 0.49 2 50 14,250 0.25 2.30>1 14,250 091 2.20 18 C 87 2.3 .250 0.20 2.80 ;: 14,250 0.49 2.50 14,250 0.25 2.301 14,250 091 2.20 19 R 85 013 2.6 1.000 0.15 2.80 11,000 0.38 2,70 11,000 0.19 2.50'' 11,000 070 2.50 20 R 84 0.84 2.5 3,750 0.19 2.90 13,750 OA7 2.70 13,750 0.24 2.50M 13,750 088 2.50 21 C 81 2.5 2,750 0.18 2.70 12,750 0.44 2.60 12,750 0,22 2.5 12,750 081 2,50 22 C 79 2.7 2.750 0.10 270 12.750 044 2.60 12,75U 022 2.5 12,750 081 2.50 23 C 83 2.7 3,250 0.18 2.70 ". 13,250 0.45 '2.60 13,250 0.23 2.5 13,250 084 2.40 24 C 84 2.7 3,250 0.18 2.70 � 13,250 0.45 2.60 13,250 0.23 2.5 13,250 084 2,40 25 R 84 0.72 2.7 3,250 0.18 2.70 " 13,250 0.45 =2 60 13,250 0.23 2 5 13.250 084 240 26 C 86 2.5 3,500 0.19 2.40 ' 13,500 0.46 2.40 13,500 0.23 2.4 13,500 086 2.30 27 C 86 2.6 1,250 0.16 2.40 : 11,250 0.39 .2.40 11,250 0.20 2.500 11,250 0 72 2.30 28 C 90 90 2.6 4,250 2.6 3,250 0.20 0.18 2.40 , i 2A0 14,250 13.250 0.49 2.40 0.45 2.50 14,250 13,250 0.25 0.23 2.6 M 14,250 13,250 091 2.40 29 C 084 L 2.40 if 30 C 89 2.6 5,062 0.21 2.60 15,U62 0.52 -2.50 15,062 U 2e __L.60M 2.60 15,062 096 2.40 31 R 88 0,03 26 5,062 0.21 2.60 15,062 0.52 .50 15,062 0.26 2.60 15,062 096 2.40 Month) LoadingGPD/ft2: Year to Date Loading GPQ1f 0.19 Z.07 0.48 5 13 G Z4 0 24 090 q 62 1.2 FORM NDAR-2 10-13 NON -DISCHARGE APPLICATION REPORT (NDAR-2) Page a _ cf Did the application rates exceed the limits in Attachment B of your permit? 11compiait r_1NWcor7pl,ant If not a basin, were the sites kept free of vegetation and raked? -i comphart ❑NmComcbmt If not a basin, were there any instances of effluent ponding in or runoff from the sites? acom0lant �NcrComoiant If a basin, were there any instances of breakout from the berms? ElUmptiant �Norrcompliart Was the onsite automatically activated standby power source tested and operational? ElcomOiart �flkoCompLant If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the noncompliance and describe the corrective action(s) taken. Attach additional sheets if necessary. Operator in Responsible Charge (ORC) Certification Permittee Certification ORC: Raymond Lacy Braxton Permiftee: Aqua, North Carolina INC Certification No.: 999895 Signing Official: Katie'BtCkCFls )✓)C_jCC,_,,` Grade: IV Phone Number: 910 431-9248 Signing Official's Title: Coastal Regional Supervisor Has the ORC changed since the previous NDAR-2? yesQ, do Phone Number: 910 779-0794 Permit Exp.: 8/31/24 lak"� 114_c 9 /2zf Signature Date Signature Date By the sL"ure. I ca'lify that the report is accurate and compiew to ire test d my knowledge I cewtify, Laufer penalty of taw, inat tvs docwnwit and fit attactvnCtXs wore praWad undor my ckrereon or supervision in accordance with a system dosignod to assure thffi all quiMed porsornd properly gathered and evaluated ffxr inlormmon submitted Basal on my inqury a tho person or persons who manage the system, or those pawns dirfctly responsible for gathering ffm information. ft irAamabon submitted is, to thobost of my knowledge and Whet. true. accurate, and complow. I am aware that tiers are sigrefieart pensibes tar submitting false information, mclud rig tole possitaity d fins and Imprisonment for knowing violation. Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617