Loading...
HomeMy WebLinkAboutWQ0044990_More Information (Requested)_20240624ROY COOPER Governor ELIZABETH S. BISER Secretary RICHARD E. ROGERS,]R. Director ABIGAIL F. SIEGRIST 168 MURPHY DRIVE HIGH POINT, NORTH CAROLINA 27265 Dear Mrs. Siegrist, NORTH CAROLINA Environmental Quality June 24, 2024 Subject: Application No. WQ0044990 Additional Information Request #2 312 Reese Rd. SFR Single -Family Residence Wastewater Irrigation System Davidson County Division of Water Resources' Central and Regional staff have reviewed the application package received on December 7, 2023 and additional information received on April 8, 2024. However, the Division requires additional information before completing our review. Please address the items on the attached pages no later than the close of business on July 24, 2024. Please be aware that the Applicant is responsible for meeting all requirements set forth in North Carolina rules and regulations. The Applicant is also responsible for any oversights that occur during the review of the subject application package. The Division may return the application as incomplete pursuant to 15A NCAC 02T .0107(e)(2) if any omissions are made when responding to the outstanding items in Sections A through F or the Applicant fails to provide the additional information on or before the above - requested date. Please reference the subject application number when providing the requested information. The Applicant shall sign, seal, and date (where applicable) all revised and/or additional documentation and submit an electronic response to my attention via the Non -Discharge online portal. If you have any questions regarding this request, please contact me at (919) 707-3655 or cord.anthony(j�deq.nc.gov. Thank you for your cooperation. Docu Signed by: Sincerely, E z2n� 2D03237162FA4E5... Cord Anthony, Engineer II Division of Water Resources cc: Winston-Salem Regional Office, Water Quality Regional Operations Section (Electronic Copy) David C. Barcal, PE — MacConnell & Associates, P.C. (Electronic Copy) Laserfiche File (Electronic Copy) North Carolina Department of Environmental Quality I Division of Water Resources D E Q�� 512 North Salisbury Street 11617 Mail Service Center I Raleigh, North Carolina 27699-1617 NaRrHCARouNA o^wrt t^r 0--zl /� 919.707.9000 Mrs. Abigail F. Siegrist June 24, 2024 Page 2 of 2 A. Setback Waivers: 1. Multiple setback waivers were referenced in the Additional Information submitted, however, only one waiver was included. Please submit copies of all relevant setback waivers. B. Soil Evaluation: 1. In the soils report, page 47 shows three ksat nests while page 48 shows four ksat nests. Please confirm the number of ksat nests used during the soil analysis. If four have been performed, then please provide the fourth soil profile description. C. Engineering Calculations: 1. Within the calculations and form SFRWWIS 06-16, a dispersal area of 5,007 square feet and a provided loading rate of 14.03 in/year. This corresponds to an average daily disposal capacity of 119.98 GPD. This is insufficient for the 270 GPD facility applied for. The loading rate provided by the soil scientist (32.2 in/yr) gives a capacity of 275.37 GPD. Please correct the design loading rate or adjust the design so that the minimum 270 GPD flowrate is achieved.