Loading...
HomeMy WebLinkAboutWM0501664_Clayton Village Cleaners DSCA Site DC510003_20241016 October 16, 2024 Mr. Scott Stupak North Carolina Department of Environmental Quality On behalf of Clayton Village, LLC Petitioner for DSCA Site DC510003 1646 Mail Service Center Raleigh, NC 27699-1646 Sent Via Email Subject: Monitoring Well Construction Permit # WM0501664 Clayton Village Cleaners (DSCA Site DC510003) 10183 US Highway 70 West Clayton, NC 27520 – Johnston County Mr. Stupak: In accordance with the application received on October 4, 2024, we are forwarding herewith Monitoring Well Construction Permit No. WM0501664 dated October 16, 2024, issued for the construction of a monitoring well. Please be aware that some counties have well construction programs, and you may be required to obtain a well construction permit before installation. This Permit will be effective from the date of its issuance and shall be subject to the conditions and limitations as specified therein. Please note the addition of stipulation #3 to the permit enclosed. If you have any questions about this permit, please contact Michael Hall at (919) 791-4237 or via email at michael.hall@deq.nc.gov. Sincerely, Michael Hall, Regional Supervisor Water Quality Regional Operations Section Raleigh Regional Office Division of Water Resources, NCDEQ Enclosure -Permit -Application Package Ec: Jeremy Robbins, ATC Associates of North Carolina, P.C. Laserfiche NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF WATER RESOURCES PERMIT FOR THE CONSTRUCTION OF A MONITORING WELL In accordance with the provisions of Article 7, Chapter 87, North Carolina General Statutes, and other applicable Laws, Rules and Regulations. PERMISSION IS HEREBY GRANTED TO Clayton Village, LLC (Petitioner for DSCA Site DC510003) FOR THE CONSTRUCTION OF A MONITORING WELL owned by Clayton Village, LLC (Petitioner for DSCA Site DC510003) at mailing address 1646 Mail Service Center, Raleigh, NC 27699-1646. The wells will be located on the property owned by East Village Investments, LLC, at the Unaddressed Parcel (PIN 166806-38-9260) on East Front Street, Clayton, NC 27520. This Permit is issued in accordance with the application received on October 4, 2024, in conformity with specifications and supporting data, all of which are filed with the Department of Environmental Quality and are considered integral parts of this Permit. This Permit is for well construction only and does not waive any provision or requirement of any other applicable law or regulation. Construction of any well under this Permit shall be in strict compliance with the North Carolina Well Construction Regulations and Standards (15A NCAC 02C .0100), and other State and Local Laws and regulations pertaining to well construction. If any requirements or limitations specified in this Permit are unacceptable, you have a right to an adjudicatory hearing upon written request within 30 days of receipt of this Permit. The request must be in the form of a written petition conforming to Chapter 150B of the North Carolina General Statutes and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, North Carolina 27699-6714. Unless such a demand is made, this Permit is final and binding. This Permit will be effective for one year from the date of its issuance and shall be subject to other specified conditions, limitations, or exceptions as follows: 1. Issuance of this Permit does not obligate reimbursement from State trust funds, if these wells are being installed as part of an investigation for contamination from an underground storage tank or dry cleaner incident. 2. Issuance of this Permit does not supersede any other agreement, permit, or requirement issued by another agency. 3. The well(s) shall be located and constructed as shown on the attachments submitted as part of the Permit application. 4. Each well shall have a Well Contractor Identification Plate in accordance with 15A NCAC 02C .0108(o). 5. Well construction records (GW-1) for each well shall be submitted to the Division of Water Quality’s Information Processing Unit within 30 days of the well completion. 6. When the well is discontinued or abandoned, it shall be abandoned in accordance with 15A NCAC 02C .0113 and a well abandonment record (GW-30) shall be submitted to the Division of Water Quality’s Information Processing Unit within 30 days of the well abandonment. 7. If the well penetrates any water-bearing zone that contains contaminated waters, the upper three feet of the well shall be grouted within one day after the casing is set or the well abandoned. ____________________________________ Michael Hall, Regional Supervisor Division of Water Resources, Raleigh Regional Office By Authority of the Environmental Management Commission Permit Number: WM0501664 Permit Issued: October 16, 2024 2725 East Millbrook Road Suite 121 Raleigh, NC 27604 Tel: 919-871-0999 Fax: 919-871-0335 www.atcgroupservices.com N.C. Engineering License No. C-1598 October 2, 2024 Mr. Michael Hall Raleigh Regional Office North Carolina Department of Environmental Quality Water Quality Regional Operations Section 1628 Mail Service Center Raleigh, North Carolina 27699-1628 Re: Permit to Construct Monitoring Wells Clayton Village Cleaners 10183 US Highway 70 West Clayton, Johnston County, North Carolina DSCA Site ID DC510003 Dear Mr. Hall: Enclosed please find three applications for permits to construct four permanent groundwater monitoring wells. The permanent groundwater monitoring wells will be installed across three properties at an unaddressed parcel on East Front Street (PIN 166806-38-9809), an unaddressed parcel on East Front Street (PIN 166806-38-9260), and milepost h-097 1,357 (+/-) feet (PIN: 10) in Clayton, Johnston County, North Carolina. The permit applications, site map with the proposed locations of the monitoring wells, well construction details, and other relevant information are enclosed as attachments. Please review this package and return the approved permit to this office or via email to Jeremy.Robbins@OneAtlas.com. If you have any questions or require additional information, please contact our office at (919) 871-0999. Sincerely, ATC Associates of North Carolina, P.C. Jeremy J. Robbins, P.G. Project Manager FOR OFFICE USE ONLY PERMIT NO. ISSUED DATE NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY - DIVISION OF WATER RESOURCES APPLICATION FOR PERMIT TO CONSTRUCT A MONITORING OR RECOVERY WELL SYSTEM PLEASE TYPE OR PRINT CLEARLY In accordance with the provisions of Article 7, Chapter 87, General Statutes of North Carolina and regulations pursuant thereto, application is hereby made for a permit to construct monitoring or recovery wells. 1. Date: 10/02/24 2. County: Johnston 3. What type of well are you applying for? (monitoring or recovery): Permanent Monitoring Wells 4. Applicant: Clayton Village, LLC (Petitioner for DSCA Site ID DC510003) Telephone: (919) 707-8363 Applicant’s Mailing Address: DWM DSCA Program Attn: Scott Stupak, 1646 Mail Service Center, Raleigh, NC 27699-1646 Applicant’s Email Address (if available): Scott.Stupak@deq.nc.gov 5. Contact Person (if different than Applicant): Jeremy Robbins, ATC Telephone: (919) 871-0999 Contact Person’s Mailing Address: 2725 E. Millbrook Road, Suite 121, Raleigh, NC 27604 Contact Person’s Email Address (if available): Jeremy.Robbins@oneatlas.com 6. Property Owner (if different than Applicant): East Village Investments, LLC (Attn: Thomas Taft, Sr.) Telephone: (252) 638-4265 Property Owner’s Mailing Address: 227 E. Front Street, New Bern, NC 28560-2145 Property Owner’s Email Address (if available): Thomas@tfonc.com 7. Property Physical Address (Including PIN Number) Unaddressed Parcel on East Front Street (NC PIN 166806-38-9260) City Clayton County Johnston Zip Code 27520 8. Reason for Well(s): Assessment of groundwater contamination (ex: non-discharge permit requirements, suspected contamination, assessment, groundwater contamination, remediation, etc.) 9. Type of facility or site for which the well(s) is(are) needed: NCDEQ DSCA Program Site (ex: non-discharge facility, waste disposal site, landfill, UST, etc.) 10. Are there any current water quality permits or incidents associated with this facility or site? If so, list permit and/or in cident no(s). DSCA Site ID DC510003 11. Type of contaminants being monitored or recovered: chlorinated solvents (ex: organics, nutrients, heavy metals, etc.) 12. Are there any existing wells associated with the proposed well(s)? If yes, how many? Yes, 5 offsite and 6 onsite Existing Monitoring or Recovery Well Construction Permit No(s).: WM0501271 and WM0501426 13. Distance from proposed well(s) to nearest known waste or pollution source (in feet): ~575 ft NNE 14. Are there any water supply wells located less than 500 feet from the proposed well(s)? No If yes, give distance(s): N/A 15. Well Contractor: Geologic Exploration, Inc. Certification No.: 4459-A Well Contractor Address: 176 Commerce Boulevard, Statesville, NC 28625 PROPOSED WELL CONSTRUCTION INFORMATION 1. As required by 15A NCAC 02C .0105(f)(7), attach a well construction diagram of each well showing the following: a. Borehole and well diameter e. Type of casing material and thickness b. Estimated well depth f. Grout horizons c. Screen intervals g. Well head completion details d. Sand/gravel pack intervals Continued on Reverse PROPOSED WELL CONSTRUCTION INFORMATION (Continued) 2. Number of wells to be constructed in unconsolidated material: 1 3. Number of wells to be constructed in bedrock: 0 4. Total Number of wells to be constructed: 1 (add answers from 2 and 3) 5. How will the well(s) be secured? Locking well cap, flush-mount steel protective casing 6. Estimated beginning construction date: 11/11/24 7. Estimated construction completion date: 11/14/24 ADDITIONAL INFORMATION 1. As required by 15A NCAC 02C .0105(f)(5), attach a scaled map of the site showing the locations of the following: a. All property boundaries, at least one of which is referenced to a minimum of two landmarks such as identified roads, intersections, streams, or lakes within 500 feet of the proposed well or well system. b. All existing wells, identified by type of use, within 500 feet of the proposed well or well system. c. The proposed well or well system. d. Any test borings within 500 feet of proposed well or well system. e. All sources of known or potential groundwater contamination (such as septic tank systems, pesticide, chemical or fuel storage areas, animal feedlots as defined in G.S. 143-215.10B(5), landfills, or other waste disposal areas) within 500 feet of the proposed well or well system. SIGNATURES The Applicant assumes total responsibility for ensuring that the well(s) will be located, constructed, maintained, and abandoned in accordance with 15A NCAC 02C. on behalf of DSCA Petitioner for DSCA Site ID DC700002 Agent for Petitioner for DSCA Site ID DC700002 Signature of Applicant or *Agent Title of Applicant or *Agent Jeremy Robbins * If signing as Agent, attach authorization agreement stating Printed name of Applicant or *Agent that you have the authority to act as the Agent. If the property is owned by someone other than the Applicant, the property owner hereby consents to allow the Applicant to construct well(s) as outlined in this Well Construction Permit application and acknowledges that it shall be the responsibility of the Applicant to ensure that the well(s) will be located, constructed, maintained, and abandoned in accordance with 15A NCAC 02C . See attached access consent See attached access consent Signature of Property Owner (if different than Applicant) Printed name of Property Owner (if different than Applicant) DIRECTIONS Please send the completed application to the appropriate Division of Water Resources’ Regional Office: Asheville Regional Office 2090 U.S. Highway 70 Swannanoa, NC 28778 Phone: (828) 296-4500 Fax: (828) 299-7043 Fayetteville Regional Office 225 Green Street, Suite 714 Fayetteville, NC 28301-5094 Phone: (910) 433-3300 Fax: (910) 486-0707 Mooresville Regional Office 610 East Center Avenue Mooresville, NC 28115 Phone: (704) 663-1699 Fax: (704) 663-6040 Raleigh Regional Office 3800 Barrett Drive Raleigh, NC 27609 Phone: (919) 791-4200 Fax: (919) 571-4718 Washington Regional Office 943 Washington Square Mall Washington, NC 27889 Phone: (252) 946-6481 Fax: (252) 975-3716 Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, NC 28405 Phone: (910) 796-7215 Fax: (910) 350-2004 Winston-Salem Regional Office 450 W. Hanes Mill Road Suite 300 Winston-Salem, NC 27105 Phone: (336) 776-9800 Fax: (336) 776-9797 GW-22M/R (Rev. 5-26-2022) GW-22MR (6/11) GW-22M (Rev. 5/11) TYPICAL TYPE II MONITORING WELL CONSTRUCTION DETAILS FLUSH GRADE MANHOLE CROSS SECTIONAL VIEW NOT TO SCALE LOCKABLE WELL CAP PROTECTIVE CASING AND CONCRETE PAD L1 CASING MATERIAL Steel CASING DIAMETER 8 inches CASING LENGTH 12 inches PAD DIMENSIONS 2 feet x 2 feet HEIGHT ABOVE GROUND 0 feet WELL CASING MATERIAL sch 40 PVC DIAMETER 2 inches JOINT TYPE flush threaded LENGTH 30 feet L2 BACKFILL AROUND CASING MATERIAL cement-sand grout THICKNESS 25 SEAL TYPE OF SEAL bentonite L4 THICKNESS 3' FILTER PACK TYPE OF FILTER #2 silica sand DISTANCE ABOVE SCREEN 2' WELL SCREEN L3 SCREEN MATERIAL sch 40 PVC DIAMETER 2 inches LENGTH 5 feet SLOT SIZE 0.010 inches DEPTH TO BOTTOM OF MONITORING WELL 35.0 feet DEPTH TO BOTTOM OF BOREHOLE 35.0 feet L1 =0 FT. L2 =30 FT.DIAMETER OF BOREHOLE 8.75 inches L3 =5 FT. L4 =35 FT. TITLE Permanent Monitoring Well Diagram (Example of typical MW installation displayed above) Clayton Village Cleaners 10183 US Highway 70 West 2725 E Millbrook Rd Suite 121 Clayton, NC 27520 Raleigh, NC 27604 DSCA ID #DC510003 FILE PREP. BY REV. BY DATE PROJECT NO. JR AO 10/2/2024 DC5103SL11